300 Gallon Series

300 Gallon Series
TURBOPOWER GAS
PACKAGED
WATER HEATER
AquaPLEX STORAGE TANK (UNLINED DUPLEX ALLOY)
TANK SERIES 300 GALLONS
Model
Number 
Recovery gph 
40°- 120°F 40°- 140°F
Input
Btu/h
A
B
C
21
21
4
4
3/4
3/4
10-1/4 41-3/4
10-1/4 41-3/4
Blower
Motor
Volt/Ph/
HP
Amps
1/6
115/1∅/3
1/6
115/1∅/3
10-1/4 41-3/4
* Min. Inlet
Flow Gas
Pressure
"W.C.
Dimensions (inches)
J
K
Shipping
Weight
lbs
EST
250 L 300A-TPL
375 L 300A-TPL
250
375
200
300
199,000
300,000
4.5
4.5
1390
1400
500 L 300A-TPL
500
400
399,000
4.5
21
5
3/4
1/6
115/1∅/3
1410
750 L 300A-TP
750
600
600,000
6.0
29-1/2
6
1
16
41-3/4
1/3
115/1∅/8
1490
1000 L 300A-TP
1000
800
800,000
6.0
29-1/2
8
1-1/4
16
41-3/4
1/3
115/1∅/8
1530
1250 L 300A-TP
1250
1000
1,000,000
6.0
46-1/2
8
2
16
41-3/4
1/2
115/1∅/10
1765
1500 L 300A-TP
1500
1200
1,200,000
6.5
46-1/2
8
2
16
41-3/4
1/2
115/1∅/10
1850
2000 L 300A-TP
2000
1600
1,600,000
9.0
61-1/2
10
2
27
41-3/4
1-1/2
115/1∅/20
2185
2500 L 300A-TP
2500
2000
2,010,000
10.5
61-1/2
10
2-1/2
27
41-3/4
1-1/2
115/1∅/20
2205
 Recoveries based on 83% thermal efficiency. ASHRAE 90.1 compliant for efficiency and standby loss.
 "J" dimension is for the burner housing only. Gas train may exceed this dimension.
Models with “TPL” suffix are less than 55 ppm NOx. SCAQMD models 2TPL (200MBH), 3TPL (300MBH) and 4TPL (400MBH).
 4" x 46" Channel skids for inputs ≤ 1000 MBtu/h.
4" x 54-1/2" Channel skids for inputs > 1000 MBtu/h.
* The information presented is for Natural gas 0.6 S.G.— For operation with propane (LP gas), consult factory.
** Consult the factory.
Dimensions are in inches unless otherwise specified.
For standard and optional equipment, see form PV 8050.
REAR MODULE ACCESS
* GAS PRESSURE REQUIREMENTS
SEE TABLE ABOVE FOR MINIMUM PRESSURE BY MODEL NUMBER.
MAXIMUM STATIC INLET PRESSURE:
10.5" W.C. for 199,000 - 399,000 AND 14” W.C. for > 399,000.
MODEL PREFIX
L
STD or OPTIONAL
250-1500
8"
OPTIONAL
2000-2500
18"
STANDARD
VENTING REQUIREMENTS
STANDARD ELECTRICAL REQUIREMENTS
-.02" TO -.06" W.C. (NEGATIVE PRESSURE)
CATEGORY I, TYPE B VENTING
ENTIRE VENT SYSTEM SHOULD NEVER BE SIZED BASED UPON THE
VENT CONNECTION DIAMETER EXCLUSIVELY.
FOR PROPER SIZING, CONSULT
THE NATIONAL FUEL GAS CODE UNDER “FAN-ASSISTED.”
CONTROL VOLTAGE: 120V, 1Ø, 60 HZ., 2 AMPS.
MOTOR VOLTAGE:
208V, 230V, AND 460V MOTORS ARE AVAILABLE BUT WILL REQUIRE A
SEPARATE 120V/2 amps CONTROL CIRCUIT OR AN OPTIONAL CONTROL
CIRCUIT TRANSFORMER.
PVI RESERVES THE RIGHT TO CHANGE THE DESIGN
AND SPECIFICATION WITHOUT NOTICE.
PV8055 08-15
PVI INDUSTRIES, LLC
FORT WORTH, TEXAS 76111
(800) 784-8326  (817) 335-9531  www.pvi.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project