Additional collimators
31 x 41 mm and 22 x 35 mm rectangular, for size 2 and size 1 sensors
Total filtration
2.5 mm Al
Line voltage
50/60 Hz, 115V ± 10% or 230V ± 15%
Duty cycle
self regulating, continuous operation up to 1s/60s
Stability
Automatic touch-sensitive lock-on/lock-off (HyperSphere)
Arm extension
Available in 3 lengths: 40 cm – 60 cm – 90 cm
Max arm extension
230 cm, from wall
Certification
CE 0051, cCSAus, FDA approved
Data subject to change without notice
03/2014
Classification
Electro-medical equipment
Class I type B (CEI EN 60601-1/1998, par.5)
Class IIb (CCE 93/42, annex IX)
Generator
Constant potential, microprocessor controlled
Operating frequency
145 - 230 KHz (175 KHz typical)
Focal spot
0.4 mm, (IEC 336)
Anode current
6 ; 7 mA
Voltage (kV setting)
60 ; 63 ; 65 kV
Exposure Time
0.010 – 1.000 sec, R10 and R20 scale
Source-skin distance
30 and 20 cm (12” and 8”) round, 30 cm (12”) rectangular
Irradiated field
35 x 45 mm rectangular, Ø 55 mm or
Ø 60 mm round
MRXPGB091S00
Technical data
RXDC HyperSphere+
Precision X-ray imaging
Touch activated, wireless control
www.my-ray.com
CEFLA Dental Group
Via Bicocca 14/C 40026 IMOLA (BO) - ITALY
RXDC
High-frequency X-ray unit
RXDC
High frequency X-ray unit
HyperSphere Technology
Precision imaging
Specifically conceived for digital X-ray imaging, the constant potential tube head combined with the smallest focal spot available
for intraoral imaging (0.4 mm) guarantees consistently sharp images.
Health and Safety
RXDC, with its constant potential high frequency X-ray generator, significantly reduces radiation dosage compared to traditional X-ray units.
Not only is the most harmful, low-energy radiation almost completely eliminated thanks to the high-efficiency generator,
but the embedded 12” rectangular collimator minimizes the exposed bodily surface and increases the X-ray parallelism.
This leads to better image quality and higher regard for patient’s health.
MyRay Multi-Mode
Totally automatic choice of the most appropriate combination of technical factors.
KV, mA and exposure time are determined according to patient size and anatomic
region of interest.
Simple wireless control
One handheld wireless digital control device allows you to program the unit from wherever
you are in the surgery. There are no other wall-mounted or wired control panels
to worry about. Easy-to-use and easy-to-handle, the control device offers a full range
of intuitive exposure scenarios designed to make correct X-ray acquisition a straightforward
process. No more complex programming or button-crowded panels.
Touch-sensitive
zones
RXDC defines automatically the correct exposure by selecting the region of interest.
2 conveniently placed touch-sensitive
zones unlock the tube head for quick
and easy positioning.
As soon as the operator lets go,
Multiple exposure
the tube head locks into place with
RXDC allows uninterrupted use during multiple exposures,
great precision.
such as full-mouth acquisition, thanks to the Dynamic Duty-Cycle,
based on real-time control over the bulb temperature,
RXDC features HyperSphere technology. The full-swivel ball-joint
is revolutionary in every sense. The tube head revolves
•
1%
•
10%
•
100%
visible on the handheld display.
freely around the sphere, so that practically any position
can be achieved, including vertical.
An automatic touch-sensitive lock-on/lock-off device
Quality build
enables effortless repositioning of the tube head
Lightweight, solid arms in extruded aluminium with an integrated self-balancing system reduce any risk
between exposures.
of tube head vibration during image acquisition.
Great installation versatility and multiple arm lengths available.
Comfortable grip
Ergonomically shaped areas on either side of the tube head
make rapid positioning easy and effortless to achieve.
Right at your finger tips.
Lightweight and compact
RXDC is equipped with a 12” X-ray collimator almost entirely integrated into the tube head body.
This makes the tube head itself a more compact lightweight component than would otherwise be possible.
The unique tube head design, together with the stable aluminium arms, make this unit effortless to manoeuvre.