Features & Benefits
•
•
•
- Optimized impedance for improved
power factor
- Provides neutral to ground bond
- Provides voltage matching
High Energy Surge Diverter
- Eliminates potentially damaging high
energy voltage transients
•
Noise Filter
•
Convection Cooled
•
•
•
•
•
Global Power Interface
Series 2000
Three Phase Power
Isolation transformer
Three Phase Power Conditioner
- Bi-directional design prevents
random electrical noise from interfering
with system performance
- Designed to operate without the need
for ventilation fans. No filters to clean
or replace. No fans to wear out.
At long last – versatile, efficient, and effec-
Optional Harmonic Filter
tive three phase power conditioning. The GPI
- Mitigates harmonics generated by
nonlinear load components of the
industrial system. Helps meet IEEE519.
- Protected by over current breaker
Total Manageability
- Optional Power Measurements
model 7500 Ion series power
monitor. Measures all three phase
currents and voltages, power factor,
phase angle and rotation, demand,
usage, stores waveforms, and more.
Both 60 and 50 Hz. Models
Full Safety Agency Listings
Available
POWERVAR, Inc.
1450 Lakeside Drive
Waukegan, IL 60085
Phone: 847-596-7000
Toll Free: 800-369-7179
Fax: 847-596-7100
Email: [email protected]
http://www.powervar.com
Series 2000 three phase power conditioner
from POWERVAR incorporates an optimized
impedance isolation transformer, a high energy surge diverter, and a power line noise
filter as standard power quality components.
Standard Features
•
•
•
•
•
•
Emergency Machine Off (EMO) front panel button
Front panel TVSS status LEDs
Front panel power LED
Lockout/Tagout capability
Programmable main circuit breaker on 85 kVA and larger models
Casters and levelers
Optional Features
•
•
•
•
•
•
•
Safety interlocks
Harmonic mitigation with over-current protection (5th harmonic standard)
Power Management Package includes PML monitor, phase loss detection and protection
External EMO contacts
Distribution panelboards on 85 kVA and larger models
Seismic feet
Private label
SPECIFICATIONS - North American Models
Model #
Continuous
KVA Rating
Input
Voltage
Output
Voltage
Height
(in.)
Width
(in.)
Depth
(in.)
Approx.
Weight (lbs.)
ABC10.0-XDXY
10
208/240/480/600
208/120
26
18
30
290
ABC15.0-XDXY
15
208/240/480/600
208/120
26
18
30
340
ABC20.0-XDXY
20
208/240/480/600
208/120
26
18
30
400
ABC25.0-XDXY
25
208/240/480/600
208/120
35
22
39
455
ABC30.0-XDXY
30
208/240/480/600
208/120
35
22
39
510
ABC35.0-XDXY
35
208/240/480/600
208/120
35
22
39
550
ABC45.0-XDXY
45
208/240/480/600
208/120
35
22
39
690
ABC55.0-XDXY
55
208/240/480/600
208/120
47
22
39
810
ABC65.0-XDXY
65
208/240/480/600
208/120
47
22
39
960
ABC75.0-XDXY
75
208/240/480/600
208/120
47
22
39
1010
ABC85.0-XDXY
85
480/600
480/277
54
28
39
1200
ABC100.0-XDXY
100
480/600
480/277
54
28
39
1320
ABC125.0-XDXY
125
480/600
480/277
54
28
39
1450
ABC150.0-XDXY
150
480/600
480/277
54
28
39
1600
ABC175.0-XDXY
175
480/600
480/277
54
28
39
1800
ABC200.0-XDXY
200
480/600
480/277
64
28
39
2200
ABC230.0-XDXY
230
480/600
480/277
64
28
39
2400
ABC250.0-XDXY
250
480/600
480/277
74
56
39
3000
ABC300.0-XDXY
300
480/600
480/277
74
56
39
3300
Noise Rejection - With unit under power and an ANSI/IEEE C62.41, Category A pulse applied either normal mode or common mode at the input, the noise output voltage will be
less than 10 volts normal mode and less than .5 volts (½ of one volt) common mode in a ll four quadrants (CM-NM, NM-NM, CM-CM, NM-CM). (With transformer tapped 1:1)
Surge Voltage Withstand - Tested under power to ANSI/IEEE C62.41, Category A & B (formerly IEEE587-1980). Power conditioner tested to withstand up to 6000 volts @ 500
amp ringwave and unipolar impulse of 6000 volts @3000 amp.
Transformer Construction - Transformer wires are copper and insulated with Class H materials. Windings are insulated with Nomex paper insulation before vacuum varnishing. Internal wiring is a minimum of 200 degree C rated and sleeved with Class H materials. Grain oriented silicon iron cores are constructed using 14 mil. laminations interleaved
one to one. Eddy currents are minimized and external magnetic fields are below 0.1 oersted (at 12 inches distance in any direction).
Efficiency - > 97% at full load with unity power factor
North America - POWERVAR, Inc., 1450 Lakeside Drive, Waukegan, IL 60085 - Toll Free - (800) 369-7179, Telephone - (847) 596-7000, Fax - (847) 596-7100
EMEA– POWERVAR, Ltd., 61 Shrivenham Hundred Business Park, Shrivenham, Swindon, Wiltshire, UK SN6 8TZ, Telephone - 44 (0) 1793 786050, Fax - 44 (0) 1793 782250
More information available at: http://www.powervar.com
SPECIFICATIONS - International Models
Model #
Continuous
KVA Rating
Input
Voltage
Output
Voltage
Height
(mm.)
Width
(mm.)
Depth
(mm.)
Approx.
Weight (kgs.)
ABC10.0-XDXY
10
400
400/230
660
457
762
130
ABC15.0-XDXY
15
400
400/230
660
457
762
155
ABC20.0-XDXY
20
400
400/230
660
457
762
180
ABC25.0-XDXY
25
400
400/230
889
559
990
205
ABC30.0-XDXY
30
400
400/230
889
559
990
230
ABC35.0-XDXY
35
400
400/230
889
559
990
250
ABC45.0-XDXY
45
400
400/230
889
559
990
310
ABC55.0-XDXY
55
400
400/230
1194
559
990
365
ABC65.0-XDXY
65
400
400/230
1194
559
990
435
ABC75.0-XDXY
75
400
400/230
1194
559
990
455
ABC85.0-XDXY
85
400
400/230
1732
711
990
540
ABC100.0-XDXY
100
400
400/230
1732
711
990
595
ABC125.0-XDXY
125
400
400/230
1732
711
990
653
ABC150.0-XDXY
150
400
400/230
1732
711
990
720
ABC175.0-XDXY
175
400
400/230
1732
711
990
810
ABC200.0-XDXY
200
400
400/230
1625
711
990
990
ABC230.0-XDXY
230
400
400/230
1625
711
990
1080
ABC250.0-XDXY
250
400
400/230
1880
1422
990
1350
ABC300.0-XDXY
300
400
400/230
1880
1422
990
1485
Noise Rejection - With unit under power and an ANSI/IEEE C62.41, Category A pulse applied either normal mode or common mode at the input, the noise output voltage will be
less than 10 volts normal mode and less than .5 volts (½ of one volt) common mode in a ll four quadrants (CM-NM, NM-NM, CM-CM, NM-CM). (With transformer tapped 1:1)
Surge Voltage Withstand - Tested under power to ANSI/IEEE C62.41, Category A & B (formerly IEEE587-1980). Power conditioner tested to withstand up to 6000 volts @ 500
amp ringwave and unipolar impulse of 6000 volts @ 3000 amps.
Transformer Construction - Transformer wires are copper and insulated with Class H materials. Windings are insulated with Nomex paper insulation before vacuum varnishing. Internal wiring is a minimum of 200 degree C rated and sleeved with Class H materials. Grain oriented silicon iron cores are constructed using 14 mil. laminations interleaved
one to one. Eddy currents are minimized and external magnetic fields are below 0.1 oersted (at 12 inches distance in any direction).
Efficiency - > 97% at full load with unity power factor
North America - POWERVAR, Inc., 1450 Lakeside Drive, Waukegan, IL 60085 - Toll Free - (800) 369-7179, Telephone - (847) 596-7000, Fax - (847) 596-7100
EMEA– POWERVAR, Ltd., 61 Shrivenham Hundred Business Park, Shrivenham, Swindon, Wiltshire, UK SN6 8TZ, Telephone - 44 (0) 1793 786050, Fax - 44 (0) 1793 782250
More information available at: http://www.powervar.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement