HiSeq Analysis Software User Guide for HiSeq Analysis Software v0.9 (15041353 B)

HiSeq Analysis Software User Guide for HiSeq Analysis Software v0.9 (15041353 B)
HiSeq Analysis Software v0.9
User Guide
FOR RESEARCH USE ONLY
Quick Start
Introduction
Enrichment Analysis Workflow
Whole Genome Sequencing Analysis Workflow
Additional Software
Installing HiSeq Analysis Software
Requirements
Installing HiSeq Analysis Software RPM
Validating HiSeq Analysis Software
Unpacking Reference Genome
Running HiSeq Analysis Software on Different System Types
Input Files
Sample Sheet Settings
Manifest Files
Sequencing Run Files
Enrichment Test Data Set
Running HiSeq Analysis Software under Linux
Running HiSeq Analysis Software on a Cluster
Resuming Analysis using Checkpoints
Output Files
BAM Files
VCF Files
gVCF Files
Summary of Enrichment Statistics
Technical Assistance
ILLUMINA PROPRIETARY
Part # 15041353 Rev. B
May 2013
4
5
6
8
12
13
14
15
16
17
18
19
20
26
27
28
29
30
31
32
35
36
39
43
This document and its contents are proprietary to Illumina, Inc. and its affiliates ("Illumina"), and are intended solely for the
contractual use of its customer in connection with the use of the product(s) described herein and for no other purpose. This
document and its contents shall not be used or distributed for any other purpose and/or otherwise communicated, disclosed,
or reproduced in any way whatsoever without the prior written consent of Illumina. Illumina does not convey any license
under its patent, trademark, copyright, or common-law rights nor similar rights of any third parties by this document.
The instructions in this document must be strictly and explicitly followed by qualified and properly trained personnel in order
to ensure the proper and safe use of the product(s) described herein. All of the contents of this document must be fully read
and understood prior to using such product(s).
FAILURE TO COMPLETELY READ AND EXPLICITLY FOLLOW ALL OF THE INSTRUCTIONS CONTAINED HEREIN
MAY RESULT IN DAMAGE TO THE PRODUCT(S), INJURY TO PERSONS, INCLUDING TO USERS OR OTHERS, AND
DAMAGE TO OTHER PROPERTY.
ILLUMINA DOES NOT ASSUME ANY LIABILITY ARISING OUT OF THE IMPROPER USE OF THE PRODUCT(S)
DESCRIBED HEREIN (INCLUDING PARTS THEREOF OR SOFTWARE) OR ANY USE OF SUCH PRODUCT(S) OUTSIDE
THE SCOPE OF THE EXPRESS WRITTEN LICENSES OR PERMISSIONS GRANTED BY ILLUMINA IN CONNECTION
WITH CUSTOMER'S ACQUISITION OF SUCH PRODUCT(S).
FOR RESEARCH USE ONLY
© 2013 Illumina, Inc. All rights reserved.
Illumina, IlluminaDx, BaseSpace, BeadArray, BeadXpress, cBot, CSPro, DASL, DesignStudio, Eco, GAIIx, Genetic
Energy, Genome Analyzer, GenomeStudio, GoldenGate, HiScan, HiSeq, Infinium, iSelect, MiSeq, Nextera, NuPCR,
SeqMonitor, Solexa, TruSeq, TruSight, VeraCode, the pumpkin orange color, and the Genetic Energy streaming bases
design are trademarks or registered trademarks of Illumina, Inc. All other brands and names contained herein are the property
of their respective owners.
Revision History
Part #
Revision
Date
15041353
B
April 2013
15041353
A
March
2013
HiSeq Analysis Software User Guide
Description of Change
Added adapter settings for Nextera Mate Pair Libraries.
Corrected hg19 reference genome download URL.
Initial release
3
Quick Start
Running HiSeq Analysis Software under Linux
1
Identify a run folder for your analysis. This can be but does not need to be the
original run folder for the HiSeq flow cell.
2
Create a sample sheet named SampleSheet.csv in the top level of the run folder. See
Sample Sheet Settings on page 20 for more information.
3
Start the analysis:
/path/to/illumina/HiSeqAnalysisSoftware/RunLatest -r
/path/to/your/RunFolder
Where:
• –r /path/to/your/RunFolder/ is the path to the run folder.
The analysis results will be written (by default) to the
Data/Intensities/BaseCalls/Alignment subfolder of the run folder. This can be
overridden using the -a command-line option.
Please note that if you log out of your terminal session, the HiSeq Analysis Software
command may be prematurely terminated. You can retain terminal by adding the
following to your command line:
nohup /path/to/illumina/HiSeqAnalysisSoftware/RunLatest -r
/path/to/your/RunFolder 2>&1 > logfile.txt &
Running HiSeq Analysis Software on a Cluster
When running HiSeq Analysis Software on a cluster, you need to generate a shell script
that will submit the analysis job to your queue manager. A simple shell script looks like
this:
#!/usr/bin/env bash
/path/to/illumina/HiSeqAnalysisSoftware/RunLatest -r
/path/to/your/RunFolder
The analysis software assumes that it has an entire cluster node available. In order to
queue up several analyses without overloading a compute node, it is important to
specify that each analysis job requires multiple slots on the node. SGE can be configured
to support the threaded parallel environment, so that jobs that consume an entire node
can be submitted.
For example, if you are using an SGE and want to submit a job with the shell script
Analysis.sh that reserves X slots on a compute node from the queue <queue name>,
use a command like this:
qsub -pe threaded X -q <queue name> Analysis.sh
4
Part # 15041353 Rev. B
Introduction
HiSeq Analysis Software (HAS) is a software package for processing sequencing results
generated by Illumina HiSeq sequencers. HiSeq Analysis Software performs secondary
analysis on the base calls and quality scores in bcl files generated on-instrument by the
RTA software. HiSeq Analysis Software produces information about alignment, variants,
or other analysis results for each sample in an analysis. The analysis is run with a
simple command line. Each workflow includes recommended default settings for the
available options, which are specified in the sample sheet.
The analysis workflows supported are:
} Enrichment analysis workflow
} Whole Genome Sequencing analysis workflow for the human hg19 genome.
NOTE
HiSeq Analysis Software takes a run folder with bcl files as input, along with a sample
sheet, the hg19 reference genome, and—for the Enrichment analysis—a target manifest
file and optional probe manifest file. HiSeq Analysis Software automatically performs bcl
to fastq conversion and demultiplexing according to the sample sheet.
This user guide provides instructions for running HiSeq Analysis Software v0.9 through
the Linux command-line interface for secondary analysis.
NOTE
If you want to run HiSeq Analysis Software using a Graphical User Interface, install the
Analysis Visual Controller (AVC). See Additional Software on page 12.
HiSeq Analysis Software User Guide
5
Enrichment Analysis Workflow
The Enrichment analysis workflow analyzes DNA that has been enriched for particular
target sequences using Nextera Rapid Capture. Alignment is performed with BWA and
variant calling with GATK. Variant analysis is performed for just the target regions.
Statistics reporting accumulates coverage and enrichment specific statistics for each
target as well as overall metrics.
The main output files generated by the Enrichment workflow are .bam files (containing
the reads after alignment), .vcf files (containing the variant calls), and Genome VCF
(.genome.vcf) files (describing the calls for all variant and non-variant sites in the
genome).
Figure 1 Enrichment Workflow Diagram
BWA
The Enrichment workflow uses the Burrows-Wheeler Aligner (BWA), which aligns
relatively short nucleotide sequences against a long reference sequence. BWA
automatically adjusts parameters based on read lengths and error rates, and then
estimates insert size distribution.. For more information, see http://biobwa.sourceforge.net/.
After BWA alignment, variant calling is done by GATK.
GATK
Developed by the Broad Institute, the Genome Analysis Toolkit (GATK) calls raw
variants for each sample read, analyzes the variants against known variants, and then
applies a calibration procedure to compute a false discovery rate for each variant.
Variants are flagged as homozygous (1/1) or heterozygous (0/1) in the VCF file sample
column.
GATK is the standard variant caller after BWA alignment.
For more information, see http://www.broadinstitute.org/gatk.
6
Part # 15041353 Rev. B
Picard is a suite of tools in Java that work with next generation sequencing data in BAM
format. HiSeq Analysis Software uses the CalculateHsMetrics tool in Picard to compute a
set of Hybrid Selection specific metrics from an aligned SAM or BAM file. If a reference
sequence is provided, AT/GC dropout metrics will be calculated. GC and mean coverage
information for every target can also be computed.
For more information, see: http://picard.sourceforge.net/command-line-overview.shtml
HiSeq Analysis Software User Guide
7
Enrichment Analysis Workflow
Picard Metrics
Whole Genome Sequencing Analysis Workflow
The Whole Genome Sequencing analysis workflow uses the Isaac Aligner and Isaac
Variant Caller to compare the DNA sequence in the sample(s) against the human
reference genome hg19. It identifies any variants (SNPs or indels) relative to the reference
sequence.
The main output files generated by the Whole Genome Sequencing workflow are .bam
files (containing the reads after alignment), .vcf files (containing the variant calls), and
Genome VCF (.genome.vcf) files (describing the calls for all variant and non-variant sites
in the genome).
Figure 2 Whole Genome Sequencing Workflow Diagram
Isaac
Alignment and variant calling in the Whole Genome Sequencing analysis workflow are
performed with Illumina's Isaac Alignment Software and the Isaac Variant Caller (also
referred to as Starling). The Isaac workflow generates output that consists of the realigned
and duplicate marked reads in a BAM file format, variants in a VCF file format, a
Genome VCF (gVCF) file that has an entry for every base in the reference, and a
summary of the run quality.
Isaac Aligner
The Isaac aligner aligns DNA sequencing data, single or paired end, with read lengths
and low error rates using the following steps:
} Candidate mapping positions—Identifies the complete set of relevant candidate
mapping positions using a 32-mer seed-based search.
8
Part # 15041353 Rev. B
Candidate Mapping
To align reads, the Isaac aligner first identifies a small but complete set of relevant
candidate mapping positions. The Isaac aligner begins with a seed-based search using
32-mers as seeds. The initial single-seed search is followed by a multi-seed only for the
reads that were not mapped unambiguously with a single seed.
Mapping Selection
Following a seed-based search, the Isaac aligner selects the best mapping among all the
candidates. For paired-end data sets, all mappings where only one end is aligned (called
orphan mappings) trigger a local search to find additional mapping candidates defined
by the expected minimum and maximum insert size (called shadow mappings). After
optional trimming of low quality 3' ends and adapter sequences, the possible mapping
positions of each fragment are compared, taking into account pair-end information when
available, possible gaps using a banded Smith-Waterman gap aligner, and possible
shadows. The selection is based on the Smith-Waterman score and on the log-probability
of each mapping.
Alignment Scores
The alignment scores of each read pair are based on a Bayesian model, where the
probability of each mapping is inferred from the base qualities and the positions of the
mismatches. The final mapping quality is the alignment score, truncated to 60 if above
60, and possibly corrected to known ambiguities in the reference as flagged in the seeds.
Following alignment, reads are sorted. Further analysis is performed to identify
duplicates and optionally to realign indels.
Alignment Output
After sorting the reads, the Isaac aligner generates compressed binary alignment output
files, called BAM (*.bam) files, using the following process:
} Marking duplicates—Detection of duplicates is based on the location and observed
length of each fragment. The Isaac aligner identifies and marks duplicates even
when they appear on oversized fragments or chimeric fragments.
} Realigning indels—The Isaac aligner keeps track of previously detected indels, over
a window large enough for the current read length, and applies the known indels to
all reads with mismatches.
} Generating BAM files—The first step in BAM file generation is creation of the BAM
record, which contains all required information except the name of the read. The
Isaac aligner reads data from base call (BCL) files that were written during primary
analysis on the sequencer to generate the read names. The BAM file is then created
by compressing data into blocks of 64 Kb or less.
Isaac Variant Caller
The Isaac Variant Caller (the algorithm is also referred to as Starling2) identifies single
nucleotide polymorphisms (SNPs) and small indels using the following steps:
HiSeq Analysis Software User Guide
9
Whole Genome Sequencing Analysis Workflow
} Mapping selection—Selects the best mapping among all candidates.
} Alignment score—Determines alignment scores for the selected candidates based on
a Bayesian model.
} Alignment output—Generates final output in a sorted duplicate-marked BAM file
and summary file.
} Read filtering—Filters out reads failing quality checks.
} Indel calling—Identifies a set of possible indel candidates and realigns all reads
overlapping the candidates using a multiple sequence aligner.
} SNP calling—Computes the probability of each possible genotype given the aligned
read data and a prior distribution of variation in the genome.
} Indel genotypes—Calls indel genotypes and assigns probabilities.
} Variant call output—Generates output in a compressed genome variant call (gVCF)
file. See gVCF Files on page 39 for details.
Indel Candidates
Input reads are filtered by removing any of the following:
}
}
}
}
Reads that failed primary analysis quality checks.
Reads marked as PCR duplicates.
Paired-end reads not marked as a proper pair.
Reads with a mapping quality less than 20.
Indel Calling
The variant caller proceeds with candidate indel discovery and generates alternate read
alignments based on the candidate indels. As part of the realignment process, the variant
caller selects a representative alignment to be used for site genotype calling and depth
summarization by the SNP caller. This alignment is selected to be within a certain
threshold of the most-likely of all alignments for a read.
SNP Calling
The variant caller runs a series of filters on the set of filtered and realigned reads for SNP
calling without affecting indel calls. First, any contiguous trailing sequence of N base
calls are trimmed from the ends of reads. Using a mismatch density filter, reads having
an unexpectedly high number of disagreements with the reference are masked, as
follows:
} The variant caller treats each insertion or deletion as a single mismatch.
} Base calls with more than two mismatches to the reference sequence within 20 bases
of the call are ignored.
} If the call occurs within the first or last 20 bases of a read, the mismatch limit is
applied to a 41-base window at the corresponding end of the read.
} The mismatch limit is applied to the entire read when the read length is 41 or
shorter.
Indel Genotypes
All bases marked by the mismatch density filter and any N base calls that remain after
the end-trimming step are filtered out by the variant caller. These filtered base calls are
not used for site-genotyping but appear in the filtered base call counts in the variant
caller output for each site.
All remaining base calls are used for site-genotyping. To account for the possibility of
error dependencies, the genotyping method heuristically adjusts the joint error
probability that is calculated from multiple observations of the same allele on each
strand of the genome. This method treats the highest quality base call from each allele
and strand as an independent observation and leaves the associated base call quality
scores unmodified. However, quality scores for subsequent base calls for each allele and
strand are adjusted to increase the joint error probability of the given allele above the
error expected from independent base call observations.
10
Part # 15041353 Rev. B
After the site and indel genotyping methods are complete, the variant caller applies a
final set of heuristic filters to produce the final set of non-filtered calls in the output.
The output in the genome variant call (gVCF) file captures the genotype at each position
and the probability that the consensus call differs from reference, which is expressed as a
phred-scaled quality score.
More Information
Algorithm Descriptions
A detailed description of Isaac and its algorithms has been submitted for publication:
Come Raczy, Roman Petrovski, Chris Saunders, Ilya Chorny, Semyon Kruglyak, Elliott
Margulies, Han-Yu Chuang, Morten Kallberg, Swathi A. Kumar, Arnold Liao, Kristina
M. Little, Michael Stromberg, Stephen Tanner (submitted). Isaac: Ultra-fast whole genome
secondary analysis on Illumina sequencing platforms.
Parameter Settings
The output file IsisLog.txt contains the parameter settings for the workflow used. See
Output Files on page 32 for a description.
HiSeq Analysis Software User Guide
11
Whole Genome Sequencing Analysis Workflow
Variant Call Output
Additional Software
AVC
The Analysis Visual Controller software (AVC) can be used to control HiSeq Analysis
Software with a Graphical User Interface (GUI) and is run on a Windows operating
system. AVC can be downloaded from
http://support.illumina.com/sequencing/sequencing_software/analysis_visual_controller_
avc.ilmn. For more information on installing and using AVC software, see the Analysis
Vidsual Controller User Guide.
AVC has the following benefits:
} Easy to use GUI for running the WGS and Enrichment workflows without using the
Linux command line
} Easy management of the manifest file and the reference genome
} A mechanism for parallelizing analysis across samples using projects
NOTE
AVC uses a different sample sheet format than the one used for direct input to the HiSeq
Analysis Software.
IEM
The easiest way to set up a workflow sample sheet is by using the Illumina Experiment
Manager (IEM), version 1.5 or later. IEM is a tool that helps create the required sample
sheet for use with HiSeq, HiScanSQ, GAIIx or MiSeq® system, and is available for
download from http://support.illumina.com/.
12
Part # 15041353 Rev. B
Before you install HiSeq Analysis Software, you need to check whether your system
meets the requirements. If so, you can install HiSeq Analysis Software using the RPM
package.
HiSeq Analysis Software uses the hg19 reference genome. Instructions for obtaining and
unpacking it are below (Unpacking Reference Genome on page 17). Use of other genomes is
not an option at this time.
You need root privileges to perform this installation, and to unpack the reference
genome. we recommend that the same person performs both actions.
NOTE
You need root privileges to perform the installation and to unpack the reference
genome. Illumina recommends that the same person with root privileges performs both
actions. Installation may involve setting access privileges for other users.
HiSeq Analysis Software User Guide
13
Additional Software
Installing HiSeq Analysis Software
Requirements
The requirements for running HiSeq Analysis Software on Linux are listed below.
} At least 48 GB of RAM.
} A Linux distribution supporting RPM installation (CentOS or similar).
} Hard drive (local drive, or network file system such as Isilon) with >=1 terabyte of
disk space. Scratch storage should support speeds of at least 200 MB/s for favorable
performance.
} Root (or sudo root) permissions required for software installation.
} 75 GB space in the opt directory, the default install directory. If that is not available
you need to specify a different install location with the --prefix option.
14
Part # 15041353 Rev. B
NOTE
You need root privileges to perform this installation.
1
Copy the HiSeqAnalysisSoftware-x.x.x-x.x86_64.rpm file to the new system.
2
Install the rpm:
• For installation to the default /opt/illumina directory issue the yum install
command:
sudo yum install HiSeqAnalysisSoftware-x.x.x-x.x86_64.rpm
• If you want to install to a different location you need to use the rpm command
with a --prefix option:
sudo rpm -i --prefix /install/path HiSeqAnalysisSoftwarex.x.x-x.x86_64.rpm
When using the --prefix option, the package will be placed inside the
illumina directory within your custom directory.
NOTES
} The RPM will also install mono and python which are used by the HiSeq
Analysis Software package.
} If using the rpm -i --prefix command to install the HiSeq Analysis
Software and there are errors about missing dependencies, install the
missing dependencies using yum and then try the installation again.
} The RPM is unsigned.
} You need 75 GB space in the opt directory, the default install directory. If
that is not available you need to specify a different install location with the -prefix option.
} The owner of the installation directory is root but the permissions are 755 so
everyone should be able to read and execute the program. However, if you
do run into problems with permissions, change the ownership of the
installation directory to a group containing all the users.
Symlink
The installation creates the following symlink for the Genomes root directory:
} /opt/illumina/HiSeqAnalysisSoftware/Genomes ->
/opt/illumina/scratch/iGenomes
To use a different Genomes root directory update the symlink.
Removal of HiSeq Analysis Software
To uninstall the RPM:
sudo yum remove HiSeqAnalysisSoftware.x86_64
HiSeq Analysis Software User Guide
15
Installing HiSeq Analysis Software RPM
Installing HiSeq Analysis Software RPM
Validating HiSeq Analysis Software
To validate the installation you run the following script:
/opt/illumina/scratch/InstallValidationData/ValidateInstall
Update this path if you installed to a different location using the --prefix option.
A successful validation should dsiplay this output from the script on the screen:
Starting Isaac validation run...
Isaac run passed validation
Starting BWA/GATK validation run...
BWA/GATK run passed validation
Log file written to
/opt/illumina/scratch/InstallValidationData/ValidateInstall.log
An unsuccessful validation will print one of the following lines instead:
Isaac run failed
BWA/GATK run failed
16
Part # 15041353 Rev. B
NOTE
hg19 is the only large genome available with HiSeq Analysis Software. PhiX is
automatically unpacked (to /opt/illumina/scratch/iGenomes) as part of the installation of
the HiSeq Analysis Software.
1
Make sure you have python installed and the python unpacking script located in
/opt/illumina/HiSeqAnalysisSoftware/unpackIsisReference.py, or, if you specified a
custom install directory with the --prefix option, in /<Custom_
Dir>/illumina/HiSeqAnalysisSoftware/unpackIsisReference.py).
2
Copy the packed reference genome to you computer (e.g. HiSeqAnalysisSoftware_
UCSC_hg19.tar.gz).
NOTE
The reference genome is available from
http://support.illumina.com/sequencing/sequencing_software/hiseq-analysissoftware/downloads.ilmn
3
Issue the unpacking command:
python unpackIsisReference.py
--input-file HiSeqAnalysisSoftware_UCSC_hg19.tar.gz
--jobs 2
NOTE
} The genome size is 67 GB. If that does not fit in the default genome directory,
you must specify a different location.
} The owner of the genome directory is root but the permissions are 755 so
everyone should be able to read and execute. However, if you do run into
problems with permissions, change the ownership of the genome directory to
a group containing all the users.
The command line options are:
Option
-h, --help
--inputfile=INPUTFILE
--tmp=TMP
--genomesroot=GENOMESROOT
--isaacpath=ISAACPATH
--keep-tmp
--jobs=NUMJOBS
HiSeq Analysis Software User Guide
Description
Show help message and exit
Location of HiSeq Analysis Software reference to unpack
Temp directory to use for unpacking (default /tmp)
Location to unpack reference (default
/opt/illumina/HiSeqAnalysisSoftware/Genomes)
Location of Isaac installation (/opt/illumina/Isaac/stable)
Don't delete temporary files
Maximum number of parallel operations during Isaac reference
unpacking
17
Unpacking Reference Genome
Unpacking Reference Genome
Running HiSeq Analysis Software on Different System
Types
Setting up SGE for HiSeq Analysis Software
When running on a cluster like Sun Grid Engine (SGE), HiSeq Analysis
Software assumes that it has an entire cluster node available. You should not attempt to
run other jobs on a node where HiSeq Analysis Software is executing. In order to queue
up several analyses without overloading a compute node, it is important to specify the
following:
} Set your SGE to fill_up mode instead of the default round robin.
When running HiSeq Analysis Software on the cluster (see Running HiSeq Analysis
Software on a Cluster on page 30), make sure to specify the following:
} Specify the slots that HiSeq Analysis Software will request from a node using the pe threaded X in the <qsub> command line.
WARNING
The HiSeq Analysis Softwarewill use up all RAM on the node to which it is assigned. If you
do not set up your SGE properly, you can get conflicts with other jobs.
Running HiSeq Analysis Software on Non-Dedicated Servers
Illumina does not recommend running HiSeq Analysis Software on a non-dedicated
server without reserving an entire cluster node for HiSeq Analysis Software using the pe threaded X option. HiSeq Analysis Software will consume all available compute
resources in a cluster node.
18
Part # 15041353 Rev. B
User-Provided Files
Before you start an analysis, you have to modify the files listed below, and copy them to
the run folder:
} SampleSheet.csv: contains user-specified analysis options for the run. You should
modify the settings in this file and save it in the run folder prior to executing an
analysis run. See Sample Sheet Settings on page 20 for details. You can use Illumina
Experiment Manager version 1.5 or greater to create the sample sheet.
The following user-provided files are only needed for the Enrichment analysis workflow:
} Target manifest file (.txt): a tab-delimited values file that specifies targeted regions
for the aligner and variant caller, which results in faster analysis times and
visualization of results specific to these targeted regions. For Illumina-defined targets
when using Nextera Rapid Capture, you can obtain a target manifest file from
Illumina. You need to ensure that this file is present in the run folder. The format for
this file is specified in Target Manifest File on page 26.
} Probe manifest file (.txt): contains a list of all the baits (probes) regions and their
chromosome start and end positions. The format for the baits file is specified in Probe
Manifest File Format on page 26.
Sequencing Software Generated Files
The files listed below are generated by Illumina's sequencing software, and should be
present in the Run Folder after a sequencing run, before analysis starts:
} RunInfo.xml: Produced by RTA, this file contains information about cycles per read,
etc. See RunInfo.xml File on page 27.
} s_x_z.bcl: Base calls for lane x, cycle y, tile z needs to be present in
Data\Intensities\BaseCalls\L00x\Cy.1\. See BCL Files on page 27.
} s_x_yyyy.filter: Filter file for lane x, tile yyyy needs to be present in
Data\Intensities\BaseCalls\L00x\. See Filter Files on page 27.
} Position files, one of these types:
• s_x_y.locs or s_x_y.clocs: Locs or compressed locs for lane x, tile y needs to be
present in Data\Intensities\L00x\.
• *_pos: Legacy text files (Data\Intensities\s_x_yyyy_pos.txt) are also supported.
See Position Files on page 27.
HiSeq Analysis Software User Guide
19
Running HiSeq Analysis Software on Different System Types
Input Files
Sample Sheet Settings
The sample sheet identifies the samples included in an analysis, and contains the index
information used in sample demultiplexing. The Settings section of the Sample Sheet
specifies the various analysis parameter settings to be used in the analysis. Each line in
the Settings section contains a setting name in the first column and a value in the second
column. Settings are not case sensitive.
Sample sheet settings are different for the Enrichment and WGS workflows.
NOTE
The sample sheet format used by the HiSeq Analysis Software is not the same as the one
used in CASAVA or in AVC. Do not use CASAVA-style sample sheets when running the
HiSeq Analysis Software from the command line.
The HiSeq Analysis Software is packaged with the human hg19 build reference genome
provided by Illumina through iGenomes. Currently, HiSeq Analysis Software does not
support large custom genomes.
NOTE
Isis does not use the [Reads] section of the sample sheet, so if you want to analyze shorter
reads than you actually sequenced, you need to modify the RunInfo.xml file.
Sample Sheet Settings for Enrichment Workflow
The table below describes how to set up the sample sheets for the Enrichment workflow.
You must create a sample sheet using IEM or manually using a text editor.
IEM
The easiest way to set up an Enrichment workflow sample sheet is by using the Illumina
Experiment Manager (IEM), version 1.5 or later. IEM creates your sample sheet using a
wizard-based application. IEM provides a feature for recording parameters for your
sample plate, such as sample ID, dual indices, and other parameters applicable to your
samples.
WARNING
Do not use earlier versions of IEM (below v1.5). This will generate a sample sheet that was
formatted for CASAVA. Do not use CASAVA-style sample sheets when running HiSeq
Analysis Software.
Use the following settings:
} At Sample Prep Kit selection in IEM, choose:
• Instrument Selection: HiSeq 2500/2000/1000 (etc)
• Application: HiSeq Enrichment
} Select Use Adapter Trimming if your Illumina assay uses adapters.
Shorter inserts can lead to sequencing into the adapter, and this feature helps filter
out adapter sequence from the final sequence data.
You can download IEM from the Illumina website at from http://support.illumina.com/;
for instructions on how to use the IEM application, see the Illumina Experiment Manager
User Guide and Quick Reference Card. IEM can be run on any Windows platform.
Parameters
If you want to further customize the sample sheet for the Enrichment workflow beyond
default settings or settings specified by IEM, you can use the following parameters in the
[Settings] area of the sample sheets:
20
Part # 15041353 Rev. B
Description
Adapter
Specify the 5' portion of the adapter sequence to
prevent reporting sequence beyond the sample DNA.
Illumina recommends adapter trimming for Nextera
libraries (adapter sequence
CTGTCTCTTATACACATCT).
AdapterRead2
Specify the 5' portion of the Read 2 adapter sequence
to prevent reporting sequence beyond the sample
DNA. Use this setting to specify a different adapter
other than the one specified in the Adapter setting. If
not specified, the Adapter setting is used for read 2.
Aligner
Specify the method for aligning reads against the
reference genome. BWA is default and must be used
for the Enrichment workflow.
BaitManifestFileName
Specifies the full path to the probe (bait) manifest file,
or relative path if the probe manifest is present in the
runfolder.
EnrichmentMaxRegionStatisticsCount
The number of output rows in the file
EnrichmentStatistics.xml is limited to 40,000 by default
to prevent problems with displaying exome sized data
sets. This can be overridden with the sample sheet
setting EnrichmentMaxRegionStatisticsCount
Default: 40000
FlagPCRDuplicates
Settings are 0 or 1. Default is 0, do not flag.
If set to 1 or TRUE, PCR duplicates are flagged in the
BAM files and not used for variant calling.
PCR duplicates are defined as two clusters from a
paired-end run where both clusters have the exact
same alignment positions for each read.
IndelRealignment
Enables indel realignment with GATK.
Default is GATK; GATK must be used for the
Enrichment workflow.
IndelRepeatFilterCutoff
This setting filters indels if the reference has a 1-base
or 2-base motif repeated over eight times (by default)
next to the variant.
Default value for GATK: 8
MinimumCoverageDepth
The GATK variant caller does not report variants if
the coverage depth at that location is less than the
specified threshold. Decreasing this value will increase
variant calling sensitivity, but raise the risk of false
positives.
Default value for GATK: 20
MinQScore
This setting specifies the minimum base Q-score to use
as input to variant calling.
PicardHsMetrics
Default is 0. If set to 1 or TRUE, this setting allows the
user to generate Picard HS metrics for the given
probe (bait) manifest and target manifest file. If the
bait file is not explicitly identified, the target manifest
file is also used as the bait file.
HiSeq Analysis Software User Guide
21
Sample Sheet Settings
Parameter
Parameter
Description
QualityScoreTrim
If set to a value > 0, then the 3' ends of non-indexed
reads with low quality scores are trimmed. Trimming
is automatically applied by default for a value of 15
when using BWA for alignment.
StrandBiasFilter
This setting filters variants with a significant bias in
read-direction. Variants filtered out in this way will
have sb in the filter column of the VCF file, instead of
PASS.
Default value for GATK: -10
VariantCaller
Specify the variant caller.
Default is GATK; this must be used in the Enrichment
workflow.
VariantFilterQualityCutoff
This setting filters variants if the variant quality score
is less than the specified threshold.
Default value for GATK: 30
VariantFrequencyFilterCutoff
This setting filters variants with a frequency less than
the specified threshold.
Default value for GATK: 0.20
VariantMinimumGQCutoff
This setting filters sites if the genotype quality (GQ) is
less than the threshold.
Default value for GATK: 30
IEM
The easiest way to set up an Enrichment workflow sample sheet is by using the Illumina
Experiment Manager (IEM), version 1.5 or later. IEM creates your sample sheet using a
wizard-based application. IEM provides a feature for recording parameters for your
sample plate, such as sample ID, dual indices, and other parameters applicable to your
samples.
WARNING
Do not use earlier versions of IEM (below v1.5). This will generate a sample sheet that was
formatted for CASAVA. Do not use CASAVA-style sample sheets when running HiSeq
Analysis Software.
Use the following settings:
} When prompted to select a Sample Prep Kit in IEM, choose these options:
• Instrument Selection: HiSeq 2000/1000 (etc)
• Application: HiSeq Enrichment
} When using IEM for sample sheet generation, make sure you select Use Adapter
Trimming when you create your sample sheet if your Illumina assay uses adapters.
Shorter inserts can lead to sequencing into the adapter, and this feature helps filter
out adapter sequence from the final sequence data.
} The manifest specifies targeted regions for the aligner and variant caller.
} When a run completes for HiSeq, HiScan SQ, or GA instruments, the product
manifest file must be copied to the run folder before running the analysis. Also, a
sample sheet must be created using IEM or manually using a text editor..
You can download IEM from the Illumina website at from http://support.illumina.com/;
for instructions on how to use the IEM application, see the Illumina Experiment Manager
User Guide and Quick Reference Card. IEM can be run on any Windows platform.
22
Part # 15041353 Rev. B
Sample Sheet Settings
Example Enrichment Sample Sheet
An example of a sample sheet for the Enrichment workflow is shown below.
[Header]
IEMFileVersion,4
Investigator Name,John Doe
Project Name,Project A
Experiment Name,JD_0004
Date,12/5/2012
Workflow,Enrichment
Application,Enrichment
Assay,Nextera Enrichment
Description
Chemistry,Amplicon
[Manifests]
A,NexteraRapidCapture_Exome_TargetedRegions.txt
[Reads]
76
76
[Settings]
Adapter,CTGTCTCTTATACACATCT
Aligner,BWA
FlagPCRDuplicates,TRUE
[Data]
Sample_ID,Sample_
Name,Lane,Index,GenomeFolder,Manifest,Runfolder
12plx_NA12144,,1+2,TAAGGCGA,Homo_
sapiens/UCSC/hg19/Sequence/WholeGenomeFASTA,A,/Test01/Runs/T
est/Enrich/130206_D0003_0508_AH01ABCDEF
Sample Sheet Settings for WGS
The table below describes the parameters that can be defined in the [Settings] area of
sample sheets for the WGS workflow.
Parameter
Description
Adapter
Specify the 5' portion of the adapter sequence to
prevent reporting sequence beyond the sample DNA.
See the sample prep documentation for your sample.
Nextera Mate Pair Libraries—Illumina recommends
multiple adapter trimming for Nextera Mate Pair
Libraries (adapter sequences
CTGTCTCTTATACACATCT and
AGATGTGTATAAGAGACAG)
To trim two or more adapters, separate the sequences
by a plus (+) sign. (i.e. CTGTCTCTTATACACATCT+
AGATGTGTATAAGAGACAG).
HiSeq Analysis Software User Guide
23
Parameter
Description
AdapterRead2
Specify the 5' portion of the Read 2 adapter sequence
to prevent reporting sequence beyond the sample
DNA. Use this setting to specify a different adapter
other than the one specified in the Adapter setting. If
not specified, the Adapter setting is used for read 2.
Aligner
Specify the method for aligning reads against the
reference genome. For WGS workflow, use Isaac.
FlagPCRDuplicates
Settings are 0 or 1. Default is 1, filtering.
If set to 1, PCR duplicates are flagged in the BAM files
and not used for variant calling. PCR duplicates are
defined as two clusters from a paired-end run where
both clusters have the exact same alignment positions
for each read.
QualityScoreTrim
If set to a value > 0, then the 3' ends of non-indexed
reads with low quality scores are trimmed.
VariantCaller
Specify the variant caller Starling (this is the algorithm
in Isaac Variant Caller)
IndelRepeatFilterCutoff
This setting filters indels if the reference has a 1-base
or 2-base motif repeated over eight times (by default)
next to the variant.
Default value for Isaac variant caller: 8
MinimumCoverageDepth
This setting does not report variants if the coverage
depth at that location is less than the specified
threshold.
Default value for Isaac variant caller: 0
MinQScore
This setting specifies the minimum base Q-score to use
as input to variant calling.
Default value for Isaac variant caller: 17
VariantFilterQualityCutoff
This setting filters variants if the variant quality score
is less than the specified threshold.
Default value for Isaac variant caller: 20
VariantFrequencyFilterCutoff
This setting filters variants with a frequency less than
the specified threshold.
Default value for Isaac variant caller: 0.20
VariantMinimumGQCutoff
This setting filters sites if the genotype quality (GQ) is
less than the threshold.
Default value for Isaac variant caller: 20
Example WGS Sample Sheet
An example of a sample sheet for the Whole Genome Sequencing workflow is shown
below.
24
Part # 15041353 Rev. B
[Settings]
[Data]
SampleID,SampleName,GenomeFolder,RunFolder,Lanes
St1a,St1a,Homo_sapiens/UCSC/hg19/Sequence/WholeGenomeFASTA,
/scratch/130114_HF1003_0083_BC0I1EACXX,1+2
St2a,St2a,Homo_
sapiens/UCSC/hg19/Sequence/WholeGenomeFASTA,/scratch/130114_
HF1009_0173_BC1341ACXX,1+2
HiSeq Analysis Software User Guide
25
Sample Sheet Settings
[Header]
Investigator Name,John Doe,
Experiment Name,Project A
Date,09/24/2012
Workflow,Resequencing
Manifest Files
The Enrichment workflow uses two manifest files, a Target Manifest file and a Probe
Manifest file. Fixed content manifest files are available in the Downloads section of the
product support page. For Nextera Rapid Capture Exome and Expanded Exome target
manifest and probes manifest files, go to www.illumina.com | Support | Kits and
Reagents | Nextera Rapid Capture Exome | Downloads, or click
http://support.illumina.com/sequencing/sequencing_kits/nextera_rapid_capture_exome_
kit/downloads.ilmn.
Target Manifest File
The Enrichment workflow target manifest file is a tab-delimited file with two major
sections. HiSeq Analysis Software ignores the version of the manifest but parses the
Reference Genome and the Regions section. You need to copy the target manifest file
into the run folder before analysis starts.
The following fields are used in the Regions section:
}
}
}
}
}
}
Name—Unique user-specified name for the target.
Chromosome—Chromosome from which the target originates.
Start—1-based coordinate start position of the target.
End—1-based and inclusive coordinate of the end position of the target.
Upstream Probe Length—This field should be zero.
Downstream Probe Length—This field should be zero.
Figure 3 Example Manifest File
Probe Manifest File Format
The Enrichment workflow probe manifest file (baits file) is a tab-delimited file with a list
of all the baits regions and their chromosome start and end positions. The probe
manifest file is optional, and is only needed for Picard metrics. If you use the probe
manifest file, copy it into the run folder before analysis starts, or else provide a full path.
The following fields are used in the Regions section:
}
}
}
}
}
}
26
Name—Unique user-specified name for the bait.
Chromosome—Chromosome from which the bait originates.
Start—1-based coordinate start position of the bait.
End—1-based and inclusive coordinate of the end position of the bait.
Upstream Probe Length—This field should be zero.
Downstream Probe Length—This field should be zero.
Part # 15041353 Rev. B
HiSeq Analysis Software needs several sequencing run files, which are described below.
RunInfo.xml File
The top level Run Folder contains a RunInfo.xml file. The file RunInfo.xml (normally
generated by SCS/HCS) identifies the boundaries of the reads (including index reads).
The XML tags in the RunInfo.xml file are self-explanatory.
BCL Files
The BCL files can be found in the BaseCalls directory inside the run directory:
Data/Intensities/BaseCalls/L<lane>/C<cycle>.1
They are named as follows:
s_<lane>_<tile>.bcl or s_<lane>_<tile>.bcl.gz
The BCL files can be gzip compressed and the FASTQ generator accepts either format.
The BCL files are binary base call files with the format described below.
Bytes
Description
Data type
Bytes 0–3
Number N of cluster
Bytes 4–(N+3)
Where N is the
cluster index
Bits 0-1 are the bases, respectively [A, C, G, T]
for [0, 1, 2, 3]:
bits 2-7 are shifted by two bits and contain the
quality score.
All bits ‘0’ in a byte is reserved for no-call.
Unsigned 32bits little
endian integer
Unsigned 8bits integer
Filter Files
The filter files can be found in the BaseCalls directory.
The *.filter files are binary files containing filter results; the format is described below.
Bytes
Bytes 0–3
Bytes 4–7
Bytes 8–11
Bytes 12–(N+11)
Where N is the cluster number
Description
Zero value (for backwards compatibility)
Filter format version number
Number of clusters
unsigned 8-bits integer:
• Bit 0 is pass or failed filter
Position Files
The BCL to FASTQ converter can use different types of position files and will expect a
type based on the version of RTA used:
} *.locs: the locs files can be found in the Intensities/L<lane> directories.
} *.clocs: the clocs files are compressed versions of locs file and can be found in the
Intensities/L<lane> directories.
HiSeq Analysis Software User Guide
27
Sequencing Run Files
Sequencing Run Files
Enrichment Test Data Set
A data set for testing the Enrichment workflow in HiSeq Analysis Software can be
obtained from the Downloads section of the Nextera Rapid Capture Exome support
webpage. Go to www.illumina.com | Support | Kits and Reagents | Nextera Rapid
Capture Exome | Downloads, or click
http://support.illumina.com/sequencing/sequencing_kits/nextera_rapid_capture_exome_
kit/downloads.ilmn. Details on running the workflow, expected run time, input and
output files can be found in the README.txt included in the download.
NOTE
The time needed for download of test data sets may vary depending on network
performance and data set size.
28
Part # 15041353 Rev. B
The following section details running HiSeq Analysis Software under Linux.
1
Identify a run folder for your analysis. This can be but does not need to be the
original run folder for the HiSeq flow cell.
2
Create a sample sheet named SampleSheet.csv in the top level of the run folder. See
Sample Sheet Settings on page 20 for more information.
3
Start the analysis:
/path/to/illumina/HiSeqAnalysisSoftware/RunLatest -r
/path/to/your/RunFolder
Where:
• –r /path/to/your/RunFolder/ is the path to the run folder.
The analysis results will be written (by default) to the
Data/Intensities/BaseCalls/Alignment subfolder of the run folder. This can be
overridden using the -a command-line option.
Please note that if you log out of your terminal session, the HiSeq Analysis Software
command may be prematurely terminated. You can retain terminal by adding the
following to your command line:
nohup /path/to/illumina/HiSeqAnalysisSoftware/RunLatest -r
/path/to/your/RunFolder 2>&1 > logfile.txt &
TIP
} You can test the Enrichment workflow with an Illumina-provided data set;
see Enrichment Test Data Set on page 28 for more information.
} If you have sample sheets with many samples, you can split them into
smaller sample sheets and run each of these smaller analyses on separate
computers to optimize your analysis time.
Options
The following command-line options can be used to customize the analysis run:
Option Description
-r
Path to run folder (required).
-a
Path to analysis results folder.
Default: the Data/Intensities/BaseCalls/Alignment subfolder of the run folder
-c
Resume analysis at indicated checkpoint (see Resuming Analysis using Checkpoints on page
31).
NOTE
} The analysis parameters are defined in the sample sheet.
} The workflow parameter settings used in the run are recorded in the output
file IsisLog.txt. See Output Files on page 32 for a description.
HiSeq Analysis Software User Guide
29
Enrichment Test Data Set
Running HiSeq Analysis Software under Linux
Running HiSeq Analysis Software on a Cluster
When running HiSeq Analysis Software on a cluster, you need to generate a shell script
that will submit the analysis job to your queue manager. A simple shell script looks like
this:
#!/usr/bin/env bash
/path/to/illumina/HiSeqAnalysisSoftware/RunLatest -r
/path/to/your/RunFolder
The analysis software assumes that it has an entire cluster node available. In order to
queue up several analyses without overloading a compute node, it is important to
specify that each analysis job requires multiple slots on the node. SGE can be configured
to support the threaded parallel environment, so that jobs that consume an entire node
can be submitted.
For example, if you are using an SGE and want to submit a job with the shell script
Analysis.sh that reserves X slots on a compute node from the queue <queue name>,
use a command like this:
qsub -pe threaded X -q <queue name> Analysis.sh
TIP
} If you have sample sheets with many samples, you can split them into
smaller sample sheets and run each of these smaller analyses on separate
nodes to optimize your analysis time.
} You can test the Enrichment workflow with an Illumina-provided data set;
see Enrichment Test Data Set on page 28 for more information.
NOTE
See Running HiSeq Analysis Software on Different System Types on page 18 for the required
SGE configuration
Options
The following command-line options can be used for customizing when running HiSeq
Analysis Software on a cluster:
Option
-pe threaded X
-q <queue name>
–M <email ID>
-N <Job name>
Description
Requests an X-core node. The recommended value is the number of
slots in a node.
Specifies the queue <queue name> for the node request defined in -pe
threaded X. Optional.
Sends an email to <email ID> when the job is complete or when the job
exits because of an error.
Associates a job name to the job. The name should begin with an
alphabetical character.
NOTE
If your installation does not support SGE, these options will not work.
30
Part # 15041353 Rev. B
The Checkpoint.txt file, generated by the HiSeq Analysis Software, identifies the last
successfully executed step in the workflow. These are useful if the analysis has
unexpectedly stopped, or if you want to change an analysis parameter and don't want to
start the analysis from the start.
For the different workflow configurations, the following checkpoints are generated for
each analysis step:
Table 1 Checkpoints for Workflow Configurations
WGS Workflow without Enrichment Workflow without Enrichment Workflow with
Picard Metrics
Picard Metrics
Picard Metrics
Demultiplexing
Generating FastQ
files
Alignment
Variant Analysis
Calculate Picard
HS Metrics
Statistics
Evaluation
N/A
N/A
1
2
1
2
1
2
N/A
3
4
N/A
3
4
5
3
5
6
The analysis can be resumed from any of these checkpoints by using the –c argument,
as below:
/path/to/illumina/HiSeqAnalysisSoftware/RunLatest -r
/path/to/your/RunFolder -c X –a /path/to/AlignmentFolder/
With X being the last successfully completed step or the step after which analysis should
be resumed.
HiSeq Analysis Software User Guide
31
Resuming Analysis using Checkpoints
Resuming Analysis using Checkpoints
Output Files
Common Data Files
File Name
Description
*.bam files
Contains aligned reads for a given sample.
Located in <Run
folder>\Data\Intensities\BaseCalls\Alignment.
For more information, see BAM Files on page 35.
*.vcf files
Contains information about variants found at specific
positions in a reference genome.
Located in <Run
folder>\Data\Intensities\BaseCalls\Alignment.
For more information, see VCF Files on page 36.
*.genome.vcf.gz files
All variant and non-variant sites in the genome for
SampleName. Block level compression is used (bgzip) to
generate this file so that it is compatible with tabix
indexing. Similarly, tabix generated index file
corresponding to the genome.vcf.gz file are also
generated. This information is represented using the
Genome VCF (gVCF) conventions for VCF.
Located in <Run
folder>\Data\Intensities\BaseCalls\Alignment.
For more information, see gVCF Files on page 39 or
https://sites.google.com/site/gvcftools/home/about-gvcf.
Common Metrics Files
32
File Name
Description
AdapterTrimming.txt
Lists the number of trimmed bases and percentage of
bases for each tile. This file is present only if adapter
trimming was specified for the run.
Located in <Run
folder>\Data\Intensities\BaseCalls\Alignment.
*.CoverageHistogram.txt
Contains coverage depth information for every
chromosome. This file can be used to generate a coverage
histogram.
Located in <Run
folder>\Data\Intensities\BaseCalls\Alignment.
DemultiplexSummaryF1L1.txt
Reports demultiplexing results in a table with one row per
tile and one column per sample.
Located in <Run
folder>\Data\Intensities\BaseCalls\Alignment.
Part # 15041353 Rev. B
Description
ErrorsAndNoCallsByLaneTile
ReadCycle.csv
A comma-separated values file that contains the
percentage of errors and no-calls for each tile, read, and
cycle.
Located in <Run
folder>\Data\Intensities\BaseCalls\Alignment.
Mismatch.htm
Contains histograms of mismatches per cycle and no-calls
per cycle for each tile.
Located in <Run
folder>\Data\Intensities\BaseCalls\Alignment.
Summary.htm
Contains a summary web page generated from
Summary.xml.
Located in <Run
folder>\Data\Intensities\BaseCalls\Alignment.
Summary.xml
Contains a summary of mismatch rates and other base
calling results.
Located in <Run
folder>\Data\Intensities\BaseCalls\Alignment.
Enrichment Metrics Files
File Name
*.coverage.csv
Description
Contains a summary of the mean coverage and standard
deviation for each region in the manifest.
Located in <Run
folder>\Data\Intensities\BaseCalls\Alignment.
*.enrichment_summary.csv
EnrichmentStatistics.xml
A summary of performance metrics generated by the
enrichment workflow. See Summary of Enrichment Statistics
on page 43.
Located in <Run
folder>\Data\Intensities\BaseCalls\Alignment.
Contains high-level summary statistics forabout the
Enrichment run.
Located in <Run
folder>\Data\Intensities\BaseCalls\Alignment.
*.gaps.csv
Contains a summary of gaps, their position and mean gap
coverage in the alignment.
Located in <Run
folder>\Data\Intensities\BaseCalls\Alignment.
*.HsMetrics.txt
HiSeq Analysis Software User Guide
Summary of hybrid selection metrics generated by the
Picard suite of tools (CalculateHsMetrics.jar). More details
can be found here http://picard.sourceforge.net/picardmetric-definitions.shtml
Located in <Run
folder>\Data\Intensities\BaseCalls\Alignment.
33
Resuming Analysis using Checkpoints
File Name
File Name
Description
*_regions_Manifest_
Intervals.txt
A list of regions used to generate summary statistics. This is
generated from the target manifest file provided in the
sample sheet.
Common Run Progress Files
34
File Name
Description
QueuedForAnalysis.txt
Marker file that lists the HiSeq Analysis Software software
version and indicates that analysis has begun.
Located at the root level of the run folder.
IsisLog.txt
Processing log that describes every step that occurred
during analysis of the current run folder. This file does not
contain error messages.
Located at the root level of the run folder.
IsisError.txt
Processing log that lists any errors that occurred during
analysis. This file is present only if errors occurred.
Located at the root level of the run folder.
CompletedJobInfo.xml
Written after analysis is complete, contains information
about the run, such as date, flow cell ID, software version,
and other parameters.
Located at the root level of the run folder.
Checkpoint.txt
Identifies the last successfully executed step in the
workflow. This file is useful if a run failed and needs to be
resumed.
See Resuming Analysis using Checkpoints on page 31.
Located in <Run
folder>\Data\Intensities\BaseCalls\Alignment.
RunInfo.xml
Contains information about the run.
Located at the root level of the run folder.
Part # 15041353 Rev. B
The Sequence Alignment/Map (SAM) format is a generic alignment format for storing
read alignments against reference sequences, supporting short and long reads (up to 128
Mb) produced by different sequencing platforms. SAM is a text format file that is humanreadable. The Binary Alignment/Map (BAM) keeps exactly the same information as
SAM, but in a compressed, binary format that is only machine-readable.
Detailed Description
The file naming convention for aligned reads in BAM format is as follows:
SampleName_S#.bam (where # is the sample number determined by ordering in the
sample sheet).
Go to http://samtools.sourceforge.net/SAM1.pdf to see the exact SAM specification.
BWA adds some custom fields to the BAM output. See http://biobwa.sourceforge.net/bwa.shtml#4 for a description.
HiSeq Analysis Software User Guide
35
BAM Files
BAM Files
VCF Files
VCF is a text file format which contains information about variants found at specific
positions in a reference genome. The file format consists of meta-information lines, a
header line, and then data lines. Each data line contains information about a single
variant.
More information is available here:
http://www.1000genomes.org/wiki/Analysis/Variant%20Call%20Format/vcf-variant-callformat-version-41.
VCF Files from Isaac Variant Caller (WGS Workflow)
The file naming convention for VCF files is as follows: SampleName_S#.vcf (where # is
the sample number determined by ordering in the sample sheet).
The header of the VCF file describes the tags used in the remainder of the file and has
the column header. It looks like this:
##fileformat=VCFv4.1
##FORMAT=<ID=GQX,Number=1,Type=Integer,Description="Minimum of {Genotype
quality assuming variant position,Genotype quality assuming nonvariant position}">
...
##FORMAT=<ID=DPI,Number=1,Type=Integer,Description="Read depth
associated with indel, taken from the site preceding the indel.">
##INFO=<ID=TI,Number=.,Type=String,Description="Transcript ID">
...
##INFO=<ID=IDREP,Number=A,Type=Integer,Description="Number of times RU
is repeated in indel allele.">
##FILTER=<ID=IndelConflict,Description="Locus is in region with
conflicting indel calls">
...
##FILTER=<ID=HighDepth,Description="Locus depth is greater than 3x the
mean chromosome depth">
##fileDate=20130226
##source=starling
##source_version=2.0.2
##startTime=Tue Feb 26 04:18:06 2013
##cmdline=/illumina/development/Isis/2.3.20/ ... -genome-size 2861343702
##reference=file:///illumina/.../Homo_
sapiens/UCSC/hg19/Sequence/WholeGenomeFasta/genome.fa
##contig=<ID=chrM,length=16571>
...
##contig=<ID=chrY,length=59373566>
##content=starling small-variant calls
##SnvTheta=0.001
##IndelTheta=0.0001
##MaxDepth_chr1=170.97
...
##MaxDepth_chrY=15.24
#CHROM POS ID REF ALT QUAL FILTER INFO FORMAT SAMPLE
A sample line of the VCF file is shown below. The data that is used to populate each
column is also described:
36
Part # 15041353 Rev. B
VCF Files
chr22 16285888 rs76548004 T C 17 d15;q20 DP=11;TI=NM_
001136213;GI=POTEH;CD GT:GQ 1/0:17
Setting
Description
CHROM
The chromosome of the reference genome. Chromosomes appear
in the same order as the reference FASTA file (generally
karyotype order)
POS
The 1-based position of this variant in the reference chromosome.
The convention for .vcf files is that, for SNPs, this is the reference
base with the variant; for indels or deletions, this is the reference
base immediately before the variant. Variants are ordered by
position.
ID
The rs number for the snp obtained from dbSNP. If there are
multiple rs numbers at this location, the list is semi-colon
delimited. If no dbSNP entry exists at this position, the missing
value ('.') is used.
REF
The reference genotype. For example, a deletion of a single T
could be represented by reference TT and alternate T.
ALT
The allele(s) that differ from the reference read. For example, an
insertion of a single T could be represented by reference A and
alternate AT.
QUAL
A phred-scaled quality score assigned by the variant caller. Higher
scores indicate higher confidence in the variant (and lower
probability of errors). For a quality score of Q, the estimated
probability of an error is 10-(Q/10). For example, the set of Q30
calls should have a 0.1% error rate. Note that many variant callers
assign quality scores (based on their statistical models) which are
high relative to the error rate observed in practice.
FILTER
If all filters are passed, the' PASS' is written. The possible filters are
as follows:
• q20 – The variant score is less than 20. (Configurable using the
VariantFilterQualityCutoff setting in the config file)
• r8 – For an Indel, the number of adjacent repeats in the
reference (of a 1- or 2-base repeat) is greater than 8.
(Configurable using the IndelRepeatFilterCutoff setting in the
config file)
INFO
These are the possible entries in the INFO column:
• AD – Entry of the form X,Y where X is the number of reference
calls, Y the number of alternate calls.
• CD – A flag indicating that the snp occurs within the coding
region of at least one refGene entry
• DP – The depth (number of base calls aligned to a this position)
• GI – A comma separated list of gene IDs read from refGene
• NL – Noise level; an estimate of base calling noise at this
position.
• TI – A comma separated list of transcript IDs read from refGene
• SB – Strand bias at this position.
• VF – Variant frequency. The number of reads supporting the
alternate allele.
HiSeq Analysis Software User Guide
37
Setting
Description
FORMAT
The format column lists fields (separated by colons), for example,
"GT:GQ". The list of fields provided depends on the variant caller
used. The available fields are as follow:
AD – Entry of the form X,Y where X is the number of reference
calls, Y the number of alternate calls
GQ – Genotype quality
GT – Genotype. 0 corresponds to the reference base, 1
corresponds to the first entry in the ALT column, 2 corresponds to
the second entry in the ALT column, etc. The '/' indicates that there
is no phasing information.
NL – Noise level; an estimate of base calling noise at this position
SB – Strand bias at this position. Larger negative values indicate
more bias; values near zero indicate little strand bias.
VF – Variant frequency. The percentage of reads supporting the
alternate allele.
SAMPLE
The sample column gives the values specified in the FORMAT
column. One MAXGT sample column is provided for the normal
genotyping (assuming the reference). For reference, a second
column is provided for genotyping assuming the site is
polymorphic.
VCF Files from GATK (Enrichment Workflow)
The GATK variant caller generates VCF files that are slightly different from those
generated by Starling (Isaac Variant Caller). The core fields CHROM, POS, ID, REF,
ALT, and QUAL are the same; see description above. The customizable fields FILTER,
INFO, and FORMAT are different, and are defined in the header section; see
http://www.broadinstitute.org/gatk/guide/article?id=1268 for more information.
38
Part # 15041353 Rev. B
What is it?
HiSeq Analysis Software also produces the genome Variant Call Format file (gVCF).
gVCF was developed to store sequencing information for both variant and non-variant
positions, which is required for human clinical applications. gVCF is a set of
conventions applied to the standard variant call format (VCF) 4.1 as documented by the
1000 Genomes Project. These conventions allow representation of genotype, annotation,
and other information across all sites in the genome in a compact format. Typical
human whole genome sequencing results expressed in gVCF with annotation are less
than 1 Gbyte, or about 1/100 the size of the BAM file used for variant calling. If you are
performing targeted sequencing, gVCF is also an appropriate choice to represent and
compress the results.
gVCF is a text file format, stored as a gzip compressed file (*.genome.vcf.gz).
Compression is further achieved by joining contiguous non-variant regions with similar
properties into single ‘block’ VCF records. To maximize the utility of gVCF, especially for
high stringency applications, the properties of the compressed blocks are conservative -thus block properties like depth and genotype quality reflect the minimum of any site in
the block. The gVCF file can be indexed (creating a .tbi file) and used with existing VCF
tools such as tabix and IGV, making it convenient both for direct interpretation and as a
starting point for tertiary analysis.
For more information, see https://sites.google.com/site/gvcftools/home/about-gvcf.
The following conventions are used in the Isaac Variant Caller gVCF files.
Samples per File
There is only one sample per gVCF file.
Non-Variant Blocks Using END Key
Continuous non-variant segments of the genome can be represented as single records in
gVCF. These records use the standard 'END" INFO key to indicate the extent of the
record. Even though the record can span multiple bases, only the first base is provided
in the REF field to reduce file size.
The following is a simplified segment of a gVCF file, describing a segment of non-variant
calls (starting with an A) on chromosome 1 from position 51845 to 51862.
##INFO=<ID=END,Number=1,Type=Integer,Description="End position
of the variant described in this record">#CHROM POS ID REF
ALT QUAL FILTER INFO FORMAT NA19238chr1 51845 . A . . PASS
END=51862
Any fields provided for a block of sites such as read depth (using the DP key), will show
the minimum value observed among all sites encompassed by the block. Each sample
value shown for the block, such as the depth (using the DP key), is restricted to a range
where the maximum value is within 30% or 3 of the minimum. i.e. for sample value
range [x,y], y <= x+max(3,x*0.3). This range restriction applies to each of the ample
values printed out in the final block record.
Indel Regions
Note that sites which are "filled in" inside of deletions have additional changes:
All deletions:
HiSeq Analysis Software User Guide
39
gVCF Files
gVCF Files
} Sites inside of any deletion are marked with the deletion's filters, in addition to any
filters which have already been applied to the site.
} Sites inside of deletions cannot have a genotype or alternate allele quality score
higher than the corresponding value from the enclosing indel.
Heterozygous deletions:
} Sites inside of heterozygous deletions are altered to have haploid genotype entries
(e.g. "0" instead of "0/0", "1" instead of "1/1").
} Heterozygous SNV calls inside of heterozygous deletions are marked with the
"SiteConflict" filter and their genotype is unchanged.
Homozygous deletions:
} Homozygous reference and no-call sites inside of homozygous deletions have
genotype "."
} Sites inside of homozygous deletions which have a non-reference genotype are
marked with a “SiteConflict” filter, and their genotype is unchanged.
} Site and genotype quality are set to "."
The above modifications reflect the notion that the site confidence is bound by the
enclosing indel confidence.
Also note that on occasion, the variant caller will produce multiple overlapping indel
calls which cannot be resolved into two haplotypes. If this occurs all indels and sites in
the region of the overlap will be marked with the “IndelConflict” filter (see below).
Genotype Quality for Variant and Non-variant Sites
The gVCF file uses an adapted version of genotype quality for variant and non-variant
site filtration. This value is associated with the key GQX. The GQX value is intended to
represent the minimum of {Phred genotype quality assuming the site is variant, Phred
genotype quality assuming the site is non-variant}. The reason for using this is to allow a
single value to be used as the primary quality filter for both variant and non-variant
sites. Filtering on this value corresponds to a conservative assumption appropriate for
applications where reference genotype calls must be determined at the same stringency
as variant genotypes, ie:
} An assertion that a site is homozygous reference at GQX >= 30 is made assuming the
site is variant.
} An assertion that a site is a non-reference genotype at GQX >= 30 is made assuming
the site is non-variant.
Section Descriptions
The gVCF file contains the following sections:
} Meta-information lines start with ## and contain meta-data, config information, and
define the values that the INFO, FILTER and FORMAT fields can have.
} The header line starts with # and names the fields that the data lines use. These are
#CHROM, POS, ID,REF, ALT, QUAL, FILTER, INFO, FORMAT, followed by one or
more sample columns.
} Data lines that contain information about one or more positions in the genome.
Note that if you extract the variant lines from a gVCF file, you produce a conventional
variant VCF file.
Field Descriptions
40
Part # 15041353 Rev. B
Field Description
} CHROM: Chromosome: an identifier from the reference genome or an anglebracketed ID String ("<ID>") pointing to a contig.
} POS: Position: The reference position, with the 1st base having position 1. Positions
are sorted numerically, in increasing order, within each reference sequence CHROM.
There can be multiple records with the same POS. Telomeres are indicated by using
positions 0 or N+1, where N is the length of the corresponding chromosome or
contig.
} ID: Semi-colon separated list of unique identifiers where available. If this is a dbSNP
variant it is encouraged to use the rs number(s). No identifier should be present in
more than one data record. If there is no identifier available, then the missing value
should be used.
} REF: Reference base(s): A,C,G,T,N; there can be multiple bases. The value in the POS
field refers to the position of the first base in the string. For simple insertions and
deletions in which either the REF or one of the ALT alleles would otherwise be
null/empty, the REF and ALT strings include the base before the event (which is
reflected in the POS field), unless the event occurs at position 1 on the contig in
which case they include the base after the event. If any of the ALT alleles is a
symbolic allele (an angle-bracketed ID String "<ID>") then the padding base is
required and POS denotes the coordinate of the base preceding the polymorphism.
} ALT: Comma separated list of alternate non-reference alleles called on at least one of
the samples. Options are:
• Base strings made up of the bases A,C,G,T,N
• angle-bracketed ID String (”<ID>”)
• breakend replacement string as described in the section on breakends.
If there are no alternative alleles, then the missing value should be used.
} QUAL: Phred-scaled quality score for the assertion made in ALT. i.e. -10log_10 prob
(call in ALT is wrong). If ALT is ”.” (no variant) then this is -10log_10 p(variant),
and if ALT is not ”.” this is -10log_10 p(no variant). High QUAL scores indicate
high confidence calls. Although traditionally people use integer phred scores, this
field is permitted to be a floating point to enable higher resolution for low confidence
calls if desired. If unknown, the missing value should be specified. (Numeric)
} FILTER: PASS if this position has passed all filters, i.e. a call is made at this
position. Otherwise, if the site has not passed all filters, a semicolon-separated list of
codes for filters that fail. gVCF files use the following values:
• PASS: position has passed all filters
• IndelConflict: Locus is in region with conflicting indel calls.
• SiteConflict: Site genotype conflicts with proximal indel call. This is typically a
heterozygous SNV call made inside of a heterozygous deletion.
• LowGQX: Locus GQX is less than 30 or not present.
• HighDPFRatio: The fraction of basecalls filtered out at a site is greater than 0.3.
• HighSNVSB: SNV strand bias value (SNVSB) exceeds 10.
• HighSNVHPOL: SNV contextual homopolymer length (SNVHPOL) exceeds 6.
• HighREFREP: Indel contains an allele which occurs in a homopolymer or
dinucleotide track with a reference repeat greater than 8.
• HighDepth: Locus depth is greater than 3x the mean chromosome depth.
} INFO: Additional information. INFO fields are encoded as a semicolon-separated
series of short keys with optional values in the format: <key>=<data>[,data]. gVCF
HiSeq Analysis Software User Guide
41
gVCF Files
The fixed fields #CHROM, POS, ID, REF, ALT, QUAL are defined in the VCF 4.1
standard provided by the 1000 Genomes Project, while the fields ID, INFO, FORMAT,
and sample are described in the meta-information. Descriptions are provided below.
files use the following values:
• END: End position of the region described in this record.
• BLOCKAVG_min30p3a: Non-variant site block. All sites in a block are
constrained to be non-variant, have the same filter value, and have all sample
values in range [x,y], y <= max(x+3,(x*1.3)). All printed site block sample values
are the minimum observed in the region spanned by the block.
• SNVSB: SNV site strand bias.
• SNVHPOL: SNV contextual homopolymer length.
• CIGAR: CIGAR alignment for each alternate indel allele
• RU: Smallest repeating sequence unit extended or contracted in the indel allele
relative to the reference. RUs are not reported if longer than 20 bases.
• REFREP: Number of times RU is repeated in reference.
• IDREP: Number of times RU is repeated in indel allele.
} FORMAT: Format of the sample field. FORMAT specifies the data types and order of
the subfields. gVCF files use the following values:
• GT: Genotype.
• GQ: Genotype Quality.
• GQX: Minimum of {Genotype quality assuming variant position,Genotype
quality assuming non-variant position}.
• DP: Filtered basecall depth used for site genotyping.
• DPF: Basecalls filtered from input prior to site genotyping.
• AD: Allelic depths for the ref and alt alleles in the order listed. For indels this
value only includes reads which confidently support each allele (posterior prob
0.999 or higher that read contains indicated allele vs all other intersecting indel
alleles).
• DPI: Read depth associated with indel, taken from the site preceding the indel.
} SAMPLE: Sample fields as defined by the header.
42
Part # 15041353 Rev. B
The Enrichment workflow provides summary statistics for the target file provided. These
statistics are present in the SampleName_S1.enrichment_summary.csv file in the
Alignment folder. The Enrichment Summary Report is intended as a simple to use report
on a wide range of metrics. A brief description of the results is below.
NOTE
} The metrics generated by the Enrichment workflow are comparable, but not
identical, to those generated by Picard HS metrics. HiSeq Analysis Software
generated metrics do not filter PCR duplicates.
} The metrics also don't incorporate padding around targeted regions, which
will make the per cent enrichment metrics lower than tools that incorporate
padding, such as Picard HsMetrics.
} Illumina cannot provide technical support on the interpretation of the
outputs of 3rd party tools such as Picard. Creation of input files for and
automatic execution of Picard are provided as a convenience for our
customers. Please refer to the Picard user documentation for any questions
about this tool.
Statistic
Definition
Sample ID
ID of the Sample
Run Folder
Path to the Run folder
Total aligned
bases
Total aligned bases
Targeted aligned
bases
Total aligned bases in the target region
Base enrichment
(not padded)
100*( Total Aligned Bases in Targeted Regions/ Total Aligned Bases)
Percent duplicate
paired reads
Percentage of paired reads which have duplicates
Total aligned
reads
The total number of reads that aligned reads
Targeted aligned
reads
Number of reads that aligned to the target
Read enrichment
100*(Target aligned reads/ Total aligned reads)
Total length of
targeted
reference
Total length of sequenced bases in the target region
Mean region
coverage depth
The total number of targeted bases divided by the targeted region size.
Roughly equivalent to the weighted mean of the region coverage’s from the
<sample>.coverage.csv file.
Uniformity of
coverage (Pct >
0.2*mean):
The percentage of targeted base positions in which the read depth is greater
than 0.2 times the mean region target coverage depth.
HiSeq Analysis Software User Guide
43
Summary of Enrichment Statistics
Summary of Enrichment Statistics
44
Statistic
Definition
Target coverage
at 1X
Percentage targets with coverage greater than 1X
Target coverage
at 10X
Percentage targets with coverage greater than 10X
Target coverage
at 20X
Percentage targets with coverage greater than 20X
Target coverage
at 50X
Percentage targets with coverage greater than 50X
Insert Size
median
Median length of the sequenced fragment
Insert Size min
Minimum length of the sequenced fragment
Insert Size max
Maximum length of the sequenced fragment
Insert Size SD
Standard deviation of the sequenced fragment
SNPs
Total number of SNPs present in the dataset and pass the quality filters
SNPs (Percent
found in dbSNP)
100*( Number of SNPs in dbSNP/ Number of SNPs)
SNP Ts/Tv Ratio
Transition rate of SNPs that pass the quality filters/Transversion rate of SNPs
that pass the quality filters
SNP Het/Hom
Ratio
Number of Heterozygous SNPs/ Number of Homozygous SNPs
Indels
Total number of Indels present in the dataset and pass the quality filters
Indels (Percent
found in dbSNP)
100*( Number of Indels in dbSNP/ Number of Indels)
Indel Het/Hom
ratio
Number of Heterozygous Indels/ Number of Homozygous Indels
Part # 15041353 Rev. B
Technical Assistance
For technical assistance, contact Illumina Technical Support.
Table 2 Illumina General Contact Information
Illumina Website
Email
www.illumina.com
[email protected]
Table 3 Illumina Customer Support Telephone Numbers
Region
Contact Number
Region
North America
1.800.809.4566
Italy
Austria
0800.296575
Netherlands
Belgium
0800.81102
Norway
Denmark
80882346
Spain
Finland
0800.918363
Sweden
France
0800.911850
Switzerland
Germany
0800.180.8994
United Kingdom
Ireland
1.800.812949
Other countries
Contact Number
800.874909
0800.0223859
800.16836
900.812168
020790181
0800.563118
0800.917.0041
+44.1799.534000
MSDSs
Material safety data sheets (MSDSs) are available on the Illumina website at
www.illumina.com/msds.
Product Documentation
Product documentation in PDF is available for download from the Illumina website. Go
to www.illumina.com/support, select a product, then click Documentation & Literature.
HiSeq Analysis Software User Guide
Illumina
San Diego, California 92122 U.S.A.
+1.800.809.ILMN (4566)
+1.858.202.4566 (outside North America)
[email protected]
www.illumina.com