genelec 1024a specs

genelec 1024a specs
Genelec 1024A
System Specifications
Min
Typ
Max
Lower cut-off frequency, -3
dB, Hz:
29
30
33
Upper cut-off frequency, -3
dB, kHz:
17
19
Three-way, vented-box (B6)
system, dynamic drivers
3
Response tolerance, ± dB
Maximum continuous
acoustic output @ 1m on axis
in free field, dB
Harmonic distortion at 100 dB
SPL @ 1m on axis
Treble radiation loss at 45 º
off axis, dB
f < 200 Hz
f > 200 Hz
at 5 kHz
at 12 kHz
Drivers
Bass
Mid
Treble
385 mm
80 mm
21 mm
Enclosure finish
110
112
2
0.5
4
6
3
1
5
8
Typ
Max
Black
Amplifier
Min
Three class AB power amplifiers with active 3-way crossover filter, mounted
with the mains supply on the cooling plate that is also the amplifier
mechanical frame
Bass output at 8 ohms load,
VRMS
continuous
Mid output at 8 ohms load,
VRMS
continuous
Treble output at 8 ohms load,
VRMS
continuous
Slew rate V/µs
System distortions at nominal
output, %
SMPTE-IM
CCIF-IM
DIM
THD
Open-loop gain, dB
Open-loop bandwidth, kHz
24
24
Bass
Mid
Treble
Bass
Mid
Treble
Bass
11
5
20
40
10
30
60
20
0,1
0,15
0,2
0,15
56
53
55
40
0,3
0,3
0,3
0,3
Negative feedback, dB
Mid
Treble
Bass
Mid
Treble
60
100
80
110
26
25
22
Min
Typ
Crossover
Three parallel bandpass filters with common symmetric input stage and
individual output attenuators. Frequency response determing components on
a plug-in daughter board
Input impedance, kOhm
Input level, dBm
for maximum output
Bass high-pass
2nd order with adjustable damping providing
system responses of 0 dB, -2 dB, -4 dB and
-6 dB at 35 Hz
Subsonic attenuation, dB at
15 Hz
Bass Low-pass, Hz
3rd order Bessel
Mid High-pass, Hz
3rd order Bessel
Mid Low-pass, kHz
3rd order Bessel
Treble High-pass, kHz
Treble Low-pass, Hz
Input controls
Output controls
Max
10
10
12
320
320
3
3rd order Bessel
3
2nd order Butterworth
Volume, continuously variable
± 6 dB in 2 dB steps in each channel plus 4position bass response switch
40
General
Min
Input connector
Self generated noise level, at
1m on axis, dB(A)
Dry heat, operation
Shock
Vibration
Damp Heat, cycling
Cold, operation
Cold, stock
Temperature changes
Height, mm
Width, mm
Depth, mm
Weight, kg
Max
15
Operating temperature, C°
Specifications applicable, C°
Relative humidity, %
The amplifier system has
passed the following tests
Dry heat, stock
Typ
XLR 3-32
0
45
15
20
30
85
900
495
460
902
497
462
IEC 68-2, Bb
IEC 68-2-2, Bb
IEC 68-2-29, Eb
IEC 68-2-6,Fc
IEC 68-2-30, Db
IEC 68-2-1, Ab
IEC 68-2-1, Ab
IEC 68-2-14, Nb
net
60
Mains voltage, VAC
shipping
specifications
applicable
operation
Power consumption, VA
All data subject to change without prior notice
65
198
30
220
242
300