NCVT-1 Non-Contact Voltage Tester Microprocessor Controlled

NCVT-1 Non-Contact Voltage Tester Microprocessor Controlled
Non-Contact Voltage Tester
NCVT-1
Microprocessor
Controlled
Auto Power Off
Low Battery
Auto Shutdown
High Intensity Red LED
and Continuous Warning Sound
when voltage is detected
Bright Green LED
Power On Indicator
and Illuminator
The Non-Contact Voltage Tester (NCVT-1) incorporates the important qualities
you’ve come to expect from Klein Tools. High quality electronics, heavy-duty
polycarbonate plastic resins, state-of-the-art construction and a comprehensive
feature set; all result in a reliable, durable tester that will provide accurate test
readings and a long service life on the job-site, in the shop and at home.
The NCVT-1 is a convenient, compact tool that helps you work safer and faster.
F o r
P r o f e s s i o n a l s . . . S i n c e
1 8 5 7
®
Non-Contact Voltage Tester (NCVT-1)
Features
• Non-contact detection of voltage in cables, cords, circuit breakers, lighting fixtures,
switches, outlets, and wires.
• High intensity, bright green LED indicates the tester is operational and aids in
Power On Indicator & Illuminator:
illuminating the workspace.
Visual: High Intensity,
Bright Green LED
• When voltage is detected, a high intensity, bright red LED illuminates and
a warning tone sounds.
Power Off & Auto Power Off:
• Discrete digitally controlled ON/OFF power button.
• Auto power-off feature conserves and extends battery life.
• Microprocessor controlled low-battery indicator and tester shutdown.
• CAT IV 1000 Volt rating provides expanded operation and protection.
• 50 to 1000 Volt AC power operating range allows broad application.
• Durable polycarbonate plastic resin construction.
• Lightweight compact design with a convenient clip to fit securely in your pocket.
• Package contains insert card w/ integrated owner's manual and
Visual: Power On LED Turns Off
Audible: Double Warning Tone
Low Battery Indicator:
Visual: Green LED Blinks
Audible: Warning Tone
Voltage Detection Indicator:
Visual: High Intensity
Red LED
Audible: Continuous
Warning Tone
2 AAA 1.5 volt batteries.
Locking Tab
NCVT-1
CAT
IV
Power
Button
Cat. No.
Voltage
Range:
Frequency
Range:
Pollution
Degree
Batteries
Overall
Length
Width
Height
Weight
(oz.)
Weight w/
Batteries (oz.)
NCVT-1
50-1000
Volts AC
50-500 Hz
2
Two alkaline 1.5V AAA or
IEC LR03 or NEDA 24A
5.50"
(14.0 cm)
0.72"
(1.8 cm)
1.0"
(2.5 cm)
0.8 oz
(23 g)
1.6 oz
(46 g)
Standards:
AAA
UL 61010-1 2nd edition
CAN/CSA C22.2 No. 610101-04
EN 61010-1 2nd edition
IEC 61010-1:2001 2nd edition
ISA-82.02.01 (IEC 61010-1 MOD)
AA
Operating
/ Storage
Conditions:
A
Double
Insulated
Patents:
US D583,266 S
US 7,208,932 B1
E321008 3TMV
(2,000 meters) maximum
Environment:
WARRANTY:
Klein electronic test and measurement devices (and accessories), manufactured and sold for commercial or industrial uses, are warranted to be free from defects in materials and workmanship for
two years from the date of purchase (unless otherwise noted on the product packaging). THERE ARE NO IMPLIED WARRANTIES OF MERCHANTIBILITY OR FITNESS. At its option, Klein will repair
or replace, or refund the purchase price of, any product which fails to conform to this warranty under normal use and service. In no event shall Klein be liable for incidental or consequential damage.
This warranty does not apply to batteries.
WARNINGS:
WARNINGS:
• It is important that users of this tester read, understand, and follow all warnings,
cautions, safety information, and instructions in this manual before operating or
servicing this tester. Failure to follow instructions could result in death or serious injury.
• Risk of electric shock and burn. Contact with live circuits could result in death or
serious injury.
• Use caution with voltages above 30V AC as a shock hazard may exist.
• A steady red glow and continuous beep indicates voltage present. If no
indication, voltage could still be present.
• In bright light conditions, the LED visual indicators will be less visible.
• Do not use if green LED is not illuminated.
• Do not use if tester appears damaged or if the tester is not operating properly.
If in doubt, replace the tester.
• Do not apply more than the rated voltage as marked on the tester (1000 volts AC).
• Always wear approved eye protection.
• Before each use, verify operation by testing a known working circuit that is within
the rating of this tester.
• Do not rely on this tester with shielded wire. Operation may be affected by
differences in socket design and insulation thickness and type.
• Comply with local and national safety requirements.
• If this tester is used in a manner not specified by the manufacturer, protection
provided by the tester may be affected.
CAUTION:
• Do not attempt to repair this tester. It contains no serviceable parts.
• Do not expose the product to extremes in temperature or high humidity.
© 2009 Klein Tools, Inc.
Lincolnshire, IL 60069-1418
www.kleintools.com
Disposal: Please do not throw tester
or batteries in trash; please recycle.
Printed in U.S.A.
99814