ArcSource 3/K2, ArcSource 12/K2
The modules generate colored light by means of Luxeon LEDs.The products were designed to use with the
ArcPower drivers and for indoor use only.
1.Attention
During the operation the housing becomes hot (up to 90°C).
Operate only in places where the sufficient airflow to cool the module is present
The maximum surface temperature of the housing must never be exceeded.
Do not install the module near high inflammable liquids or materials.
Do not allow anything to rest on the module.
Do not use the module near high humidity or water or expose to the rain.
Do not install the module near the naked flames.
Do not install the module in dirty,dusty or badly ventilated location.
2.Installation
The ArcSource unit should be connected to the ArcPower driver according to the LEDs colour
variants (RGB,WW,CW...).
See ArcPower 36/K2 ,ArcPower 72/K2 (or ArcPower SmartWhite 36/K2, user manuals for full details of mains
power requirements and DMX operation.
Note: Set right current-carrying capacity of each LED branch (colour) in order to keep declared lifetime of LED
modules - see menu "SPE" on each ArcPower /K2 driver.
ArcSource units are supplied with 1.5 m of cable for direct connection to the ArcPower drivers.
CAUTION!
Avoid looking directly into the LED light beam at close range!
Maximum possible number of LED modules connected to the one ArcPower 36/K2 (or one LED output of the
ArcPower 72/K2) is mentioned in the table below.
Total
LEDs
Red
LEDs
Green
LEDs
Blue
LEDs
Amber
LEDs
Cool
white
LEDs
Warm
white
LEDs
Max.number
of connected
modules
Compatible power
supplies
ArcSource 3/K2 RGB
3
1
1
1
-
-
-
12
ArcPower 36/K2
ArcPower 72/K2
ArcSource 3/K2 CW
3
-
-
-
-
3
-
12
ArcPower SmartWhite 36/K2
ArcPower SmartWhite 72/K2
ArcSource 3/K2 WW
3
-
-
-
-
3
12
ArcPower SmartWhite 36/K2
ArcPower SmartWhite 72/K2
Module
(colour variant)
1
Module
(colour variant)
Total
LEDs
Red
LEDs
Green
LEDs
Blue
LEDs
Amber
LEDs
Cool
white
LEDs
Warm
white
LEDs
Max.number
of connected
modules
Compatible power
supplies
ArcSource 3/K2 R
3
3
-
-
-
-
-
12
ArcPower SmartWhite 36/K2
ArcPower SmartWhite 72/K2
ArcSource 3/K2 G
3
-
3
-
-
-
-
12
ArcPower SmartWhite 36/K2
ArcPower SmartWhite 72/K2
ArcSource 3/K2 A
3
-
-
-
3
-
-
12
ArcPower SmartWhite 36/K2
ArcPower SmartWhite 72/K2
ArcSource 3/K2 B
3
-
-
3
-
-
-
12
ArcPower SmartWhite 36/K2
ArcPower SmartWhite 72/K2
ArcSource 12/K2 RGB
12
4
4
4
-
-
-
3
ArcPower 36/K2
ArcPower 72/K2
12
2
2
2
-
-
6
2
ArcPower 36/K2
ArcPower 72/K2
12
2
2
2
-
6
-
2
ArcPower 36/K2
ArcPower 72/K2
ArcSource 12/K2 CW
12
-
-
-
-
12
-
3
ArcPower SmartWhite 36/K2
ArcPower SmartWhite 72/K2
ArcSource 12/K2 WW
12
-
-
-
-
-
12
3
ArcPower SmartWhite 36/K2
ArcPower SmartWhite 72/K2
ArcSource 12/K2 SW
12
-
-
-
-
6
6
3
ArcPower SmartWhite 36/K2
ArcPower SmartWhite 72/K2
ArcSource 12/K2 R
12
12
-
-
-
-
-
3
ArcPower SmartWhite 36/K2
ArcPower SmartWhite 72/K2
ArcSource 12/K2 G
12
-
12
-
-
-
-
3
ArcPower SmartWhite 36/K2
ArcPower SmartWhite 72/K2
ArcSource 12/K2 B
12
-
-
12
-
-
-
3
ArcPower SmartWhite 36/K2
ArcPower SmartWhite 72/K2
ArcSource 12/K2 A
12
-
-
-
12
-
-
3
ArcPower SmartWhite 36/K2
ArcPower SmartWhite 72/K2
ArcSource 12/K2
WWRGB
ArcSource 12/K2
CWRGB
3.RJ45 pin connection
RJ45 plug
(View facing pins)
Colour variants
Pin
1
2
3
4
5
6
7
8
Colour of wire
White/orange
Orange
White/green
Blue
White/blue
Green
White/brown
Brown
RGB
Red LED +
Green LED +
Blue LED +
Not used
Red LED Green LED Blue LED Not used
Single colour
Colour LED 1 +
Colour LED 2 +
Colour LED 3 +
Not used
Colour LED 1 Colour LED 2 Colour LED 3 Not used
SW
Warm White LED 1+
Cool White LED 1+
Warm White LED 2+
Cool White LED 2+
Warm White LED 1Cool White LED 1Warm White LED 2Cool White LED 2-
WWRGB/CWRGB
Red LED +
Green LED +
Blue LED +
White LED +
Red LED Green LED Blue LED White LED -
4.Technical specifications:
Total max. power consumption:
Compatible power supplies*:
Number of LEDs:
LED device:
Optical systems available:
LED colour variants:
Construction:
Weight:
Cooling:
Ingress protection:
Flammability:
ArcSource 3/K2
7.6 Watts
ArcPower 36/K2,ArcPower 72/K2
3
Luxeon K2
6°,15°,25°,38°
RGB,R,G,B,A,WW,CW,
precision turned alluminium
0.25 kg
convection
IP 2X
94V-0 flame class rating
2
ArcSource 12/K2
30 Watts
ArcPower 36/K2,ArcPower 72/K2
12
Luxeon K2
6°,15°,25°,38°
RGB,WWRGB,CWRGB,R,G,B,A,WW,CW,SW
precision turned alluminium
0.6 kg
convection
IP 2X
94V-0 flame class rating
Power /Data plug:
Power /Data cable:
type:
length:
Ambient temp.range:
Led life expectancy** :
Typical lumen maintenance:
RJ45
RJ45
24 AWG x 4P,category 5e
1.5 m
-20°C/+40°C
minimum 60,000 hrs
70%@ 60,000 hours
24 AWG x 4P,category 5e
1.5m
-20°C/+35°C
minimum 60,000 hours
70%@ 60,000 hours
* For single colour or SmartWhite modules are intended SmartWhite variants of the ArcPower supplies
** Constant operation at a current of 700mA (green,blue and white LEDs) and 420mA (red and amber LEDs)
5.Dimensions:
(All dimensions are in mm)
ArcSource 3/K2
ArcSource 12/K2
6. Accessories
ArcSource 3/K2:
- Splitter..................................1 piece (No. 13050690)
- Diffuser.................................1 piece (No. 14060065)
- MR16-Down Light Fitting......1 piece (No.17030257)
ArcSource 12/K2:
- Splitter..................................1 piece (No. 13050690)
7. Maintenance
- Keep the module dry.
- Operate only in places where the sufficient airflow to cool the module is present
- Periodically clean the front transparent cover.Use a moist, lint-free cloth. Never use alcohol or
solvents!
Version 1.3
Specifications are subject to change without notice.
3
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement