1000W DC-AC Rackmount Inverter
1000W
DC-AC
Rackmount
Inverter with transfer
switch - 1U Height
CAMERA-READY LOGOTYPE OF THE UL LISTING MARK FOR CANADA AND THE U.S.
These Marks are registered by Underwriters Laboratories Inc.
UL
C
UL
US LISTED C
US
LISTED
UL
C
US LISTED
Design Features
C
UL
US LISTED
C
UL
UL
C
Pure Sine Wave
US
LISTED
US LISTED
C
The minimum height of the registered trademark symbol shall be 3/64 of
an inch. When the overall diameter of the UL Mark is less than 3/8 of an inch,
the trademark symbol may be omitted if it is not legible to the naked eye.
UL
US
LISTED
C
UL
US
LISTED
-- Highly reliable, micro controller based, high quality Pure Sine
Wave Inverter (THD < 2%) with Transfer Switch
-- Output of inverter is synchronized in frequency and phase for
faster and safer transfer
US LISTED
C
-- Space saving, 1U height design for 19”Rack Mount installation
LISTED
-- Selectable output voltage (97 to 123 VAC) and frequency
(47 to 63 Hz)
-- Selectable On Line / Off Line Modes
-- Monitoring and Control by Local LED / LCD panel and by
remote RS-232 Interface
RELATIVE DESIGN & PROPORTIONS OF THE UL LISTING MARK FOR CANADA AND THE U.S.
KEY TO DIMENSIONS
N
P
M
O
Q
K
J
F
C F A F
G
UL
G B
J
P
UL Mark
8 units
A
13 units
B
14 units
C
15 units
D
17 units
E
20 units
F
24 units
G
29 units
H
R
I
I
J
K
L
M
N
0
“C” and “US”
34 units
P
56 units
Q
75 units
R
30 units
35 units
59 units
85 units
87 units
176 units
216 units
“LISTED”
T 201 units
T
L
D
E
H
P
I
F
T
200-195S 10M/8/98
P
Model
SR1000-124
24 VDC- 120 VAC
SR1000-148
48 VDC- 120 VAC
0
12
24
36
48
60
72
84
96
108
120
132
144
156
168
180
192
204
216
Please note:
Not all of these elements should be used together with the same UL Mark.
The word “LISTED” would only be used once — either to the right of or
below the UL Mark (as shown).
The font for all letter forms is Helvetica Condensed Black, except for
the trademark symbol , which is Helvetica Condensed Medium.
No other fonts are acceptable.
-- Adjustable Low DC Input Voltage Alarm & Shutdown for
Low Voltage Disconnect of batteries against deep discharge
-- Load / temperature controlled cooling fans save
power consumption
-- Safety: UL Listed under UL60950-1
-- EMC: Complies with FCC Part 15(B), Class B
-- Applications:
- Telecommunications
- Solar power systems
- Emergency backup power
2 YEAR WARRANTY
Model No.
OUTPUT IN
INVERTER MODE
OUTPUT IN
BY-PASS
MODE
INPUT
BYPASS RELAY
DISPLAY
REMOTE
OPERATION
PROTECTION
COOLING
COMPLIANCE
ENVIRONMENT
SR1000-124
OUTPUT VOLTAGE
OUTPUT FREQUENCY
TYPE OF OUTPUT WAVEFORM
TOTAL HARMONIC DISTORTION OF OUTPUT WAVFORM
CONTINUOUS OUTPUT POWER (AT POWER FACTOR = 1)
SURGE OUTPUT POWER (AT POWER FACTOR = 1)
PEAK EFFICIENCY (AT FULL LOAD)
AC OUTPUT CONNECTIONS
OUTPUT VOLTAGE
OUTPUT FREQUENCY
TYPE OF OUTPUT WAVEFORM
TOTAL HARMONIC DISTORTION
CONTINUOUS OUTPUT POWER
NOMINAL DC INPUT VOLTAGE
DC INPUT VOLTAGE RANGE
DC INPUT CURRENT AT NO LOAD
DC INPUT CONNECTIONS
AC INPUT CONNECTIONS
RATING
SWITCHING TIMES
LCD AND LED DISPLAYS
WIRED ON / OFF CONTROL
COMMUNICATION PORT
DRY RELAY CONTACT
LOW DC INPUT VOLTAGE ALARM
LOW DC INPUT VOLTAGE SHUTDOWN
HIGH DC INPUT VOLTAGE SHUTDOWN
SHORT CIRCUIT SHUTDOWN
OVERLOAD SHUTDOWN
OVER TEMPERATURE SHUTDOWN
REVERSE POLARITY ON DC INPUT SIDE
OVERLOAD PROTECTION - AC INPUT SOURCE
FORCED AIR COOLING
SAFETY
EMI / EMC
OPERATING TEMPERATURE RANGE
STORAGE TEMPERATURE RANGE
DIMENSIONS
(W x D x H), MM / INCHES
WEIGHT
KG
LBS
NOTE: Specifications are subject to change without notice
SR1000-148
97-123 VAC (user selectable)
97-123 VAC (user selectable)
47 to 63 Hz +/- 0.05% (user selectable)
47 to 63 Hz +/- 0.05% (user selectable)
Pure Sine Wave
< 2%
1000W
2000W
87%
88%
Dual NEMA5-20R receptacles
Same as external AC input source
Same as external AC input source
Same as external AC input source
Same as external AC input source
Load to be limited to 1000W. Protected by 12A breaker
24 VDC
48 VDC
18 to 34 VDC
36 to 60 VDC
1.4A
0.75A
M-8 screw / Wire with M-8 ring lug terminal
Inlet receptacle (IEC 60320 C14) for detachable power cord
15A
AC input source to inverter: ≤ 20 ms / Inverter to AC input source: ≤ 8 ms
Yes
By external contact closure through mechanical / transistor switch
RS-232 Serial Port for remote operation and monitoring
For remote indication of alarm / shut down conditions
19 to 23 VDC (user selectable)
38 to 46 VDC (user selectable)
18 to 22 VDC (user selectable)
36 to 44 VDC (user selectable)
30 to 34 VDC (user selectable)
60 VDC
Yes
Yes
Yes
Yes. Internal fuses will blow
12A Circuit Breaker
3 fans. Will switch on/off at specified values of load / temperature of internal hot spot
UL Listed to UL60950-1
Meets FCC Part 15(B), Class B
0oC to + 50oC / 32oF to +122oF
-30oC to 70oC / -22oF to 158oF
482.6 x 395 x 43.5 / 19 x 15.6 x 1.71
5.8
12.8
12003-SR1000-124-148-0613
To view a full selection of Samlex products visit our website at www.samlexamerica.com or contact us: 1(800) 561-5885 or [email protected]