NPH10S SERIES Isolated 10W Single Output DC-DC Converters SELECTION GUIDE

NPH10S SERIES Isolated 10W Single Output DC-DC Converters SELECTION GUIDE
NPH10S SERIES
Isolated 10W Single Output DC-DC Converters
SELECTION GUIDE
Nominal
Input Voltage
Output
Voltage
Output
Current
Current
Limit2
(V)
24
24
24
24
48
48
48
48
(V)
3.4
5.1
12.1
15.1
3.4
5.1
12.1
15.1
(A)
2.94
1.96
0.83
0.67
2.94
1.96
0.83
0.67
(A)Min
4.5
3.0
1.2
1.1
4.1
2.8
1.2
1.0
Order Code 1
NPH10S2403i
NPH10S2405i
NPH10S2412i
NPH10S2415i
NPH10S4803i
NPH10S4805i
NPH10S4812i
NPH10S4815i
FEATURES
INPUT CHARACTERISTICS
■ High Efficiency to 86%
Parameter
Conditions
Voltage Range
Continuous operation, 24V input types
Continuous operation, 48V input types 3
■ Power Density up to 1.5kW/L
(24W/in3 )
■ 1.5kV Input to Output Isolation
■ Industry Standard Pinout
■ Surge Rating to 12W
■ Non Latching Current Limit
■ Versatile Control Options
■ Continuous Rating to 10W at 72°C
Without Heatsink
■ Operation to Zero Load
■ Protected Against Load Faults
■ Internal Over Temperature Protection
■ Uses No Electrolytic Capacitors
■ UL 94V-0 Package Materials
DESCRIPTION
The NPH10S series of DC-DC Converters
combines ease of application with versatility.
The pin pattern is based on the popular
industry standard, but two additional pins
may optionally be fitted to provide a variety
of features not commonly found on units of
this type. High efficiency enables full rating
to be achieved in a small package without
heatsinking. Thermally protected against
sustained overload. The copper case
achieves efficient heat transfer and screening.
The product range has been recognised by
Underwriters Laboratory (UL) to UL 1950 for
operational insulation, file number E179522
applies.
Parameter
Conditions
Voltage Set
Point Error
50% load after 30 mins at nominal
supply voltage
Case temperature –40°C to 110°C
Load 0% - 100%
Input specified range
Temperature Coefficient
of Output Voltage
(slope)
Deviation of
Output Voltage
Line Regulation
Load Regulation
Ripple
File Number E179522.
www.dc-dc.com
(µF Max)
470
470
100
47
470
470
56
22
MIN
NOM
MAX
Units
18
36
24
48
36
75
V
V
MIN
Over any 10°C span within the
specified temperature range
TYP
MAX
Units
0.5
%
1
2.5
%
50
250
ppm°C
Specified over temperature MIN-MAX
0.5
1
%
Operating voltage range, 50% load
0% - 100% rated load 4
rms
0.05
0.1
0.5
%
%
mV
MAX
Units
70
CONTROL CHARACTERISTICS
Parameter
Conditions
Voltage Trimming
Range
Remote Switch Input 5
At rated load,
Trim control at either output
Not operating
(voltage relative
to input negative)
Start Delay
Synchronisation
Switching Frequency
5
MIN
Operating, open circuit voltage
Time from application of valid input
voltage to output being in specification
Specified drive signal
TYP
±10
%
-15
0
1.5
9
10
11
25
320
330
350
V
mS
440
395
kHz
kHz
ABSOLUTE MAXIMUM RATINGS
Input voltage, 24V input types
Input voltage, 48V input types
Output Voltage
Output trim control
Synchronisation/shutdown control
–0.5V to 40V 6
–0.5V to 80V 6
–0.3V to controlled output voltage (operating or non-operating)
–1V to +30V
±15V relative to input return
ISOLATION CHARACTERISTICS
Parameter
Conditions
Isolation Voltage
Resistance
Flash tested for 1 second
Viso=500VDC
3.3V and 5V output
12V and 15V output
Capacitance
UL 1950 RECOGNISED
(%)
79
83
86
86
80
83
86
87
OUTPUT CHARACTERISTICS
Overall
Voltage Error
■ Fixed Frequency
Load
Efficiency Capacitance
MIN
TYP
1500
1
MAX
Units
VDC
GΩ
50
90
pF
1 If optional pins ADJ and SS are required (as indicated in the pin connections diagram) prefix the ending “i” with
an E when ordering, e.g. NPH10S4803Ei.
2 Current is quoted when output is 95% of regulated voltage.
3 For applications requiring UL1950 recognition, input voltage must not exceed 60VDC.
4 A minimum load of 10% of rating is recommended for typical applications ; see application notes.
5 Optional - Where fitted.
6 Absolute maximum value for 30 seconds. Prolonged operation may damage the product.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
NPH10S SERIES
Isolated 10W Single Output DC-DC Converters
ENVIRONMENTAL
THERMAL PERFORMANCE
Parameter
Conditions
MIN
Case Temperature
Storage
Relative Humidity
Thermal Protection
Full load
Absolute MAX internal temperatur e
Non condensing 85°C
Operates at case temperatur e
–40
–40
TYP
MAX
Units
110
125
85
°C
°C
%
°C
110
15
2415
2412
MAX power rating with case temperature maintained by external means
(eg forced air cooling)
0
-40
Case Temperature
NPH10S2403
NPH10S2405
NPH10S2412
NPH10S2415
NPH10S4803
NPH10S4805
NPH10S4812
NPH10S4815
2403
5
THERMAL CHARACTERISTICS
Part Number
2405
10
100°C
10
10
10
12
10
10
12
12
105°C
7
8.2
9.5
9.5
7
4.7
8
7.5
110°C
2.3
3
4
4
1
1
0
0
-20
0
20
40
W
10
4803
5
0
-40
-20
0
20
40
-VIN
20.32
ADJ *
0V
9.96
C&D Technologies (NCL) Limited reserve the right to alter or improve the
specification, internal design or manufacturing process at any time, without
notice. Please check with your supplier or visit our web site to ensure that
you have the current and complete specification for your product before use.
For information and instructions on use, please consult the NPH SERIES
APPLICATION NOTES.
© C&D Technologies (NCL) Limited 2000
20.32
Weight: 22g
All dimensions in mm ±0.25mm
All pins on a 2.54mm pitch and within ±0.25mm of true position
* Optional pins
C&D Technologies (NCL) Ltd
Tanners Drive, Blakelands North
Milton Keynes MK14 5BU, England
Tel: +44 (0)1908 615232
Fax:+44 (0)1908 617545
email: [email protected]
NDC NPH10S.2
No part of this publication may be copied, transmitted or stored in a
retrieval system or reproduced in any way including, but not limited to,
photography, photocopy, magnetic or other recording means, without prior
written permission from C&D Technologies (NCL) Limited.
Instructions for use are available from www.dc-dc.com
5.84
www: http://www.dc-dc.com
60
80
Ambient Temperature (°C)
+ V OUT
* SS
+VIN
25.00
1.04
0.90
4812
W
5.08
Ø
100 120
4815
4805
32.00
10.00
80
15
Units
MECHANICAL DIMENSIONS
4.50
3.70
60
Ambient Temperature (°C)
C&D Technologies (NCL), Inc.
8917 Glenwood Avenue, Raleigh
NC 27612, USA
Tel: +1 (919) 571-9405
Fax: +1 (919) 571-9262
email: [email protected]