Manual 13289494
REVISIONS
REV
RF MOUNTING FLANGE
& WELD FTG.
(SEE TABLE/SHEET 2 FOR SIZES)
STUDS, NUTS & GASKET
DESCRIPTION
AD
ENSURE THAT THE VALVE HANDLE/ACTUATOR WHEEL
IS CENTERED BETWEEN INSERTION RODS
AND THAT INSERTION RODS STRADDLE PIPE
GENERAL UPDATES
CHG.NO.
APP'D
DATE
DSI1003490
JR
09/15/10
4.00
[101,6]
VALVE BONNET
ASSY.
3.00
[76,2]
SENSOR SIZE 1
LOCKING PIN
9.00
[228,6]
MAX.
10.50
[266,7]
OPTIONAL RTD PORT
5.50
[139,7]
MAX.
3
LOW PRESSURE
INSTRUMENT
VALVE
HIGH PRESSURE
INSTRUMENT VALVE
EQUALIZER VALVE
PACKING
ASSY.
FLOW
MANUAL
INSERT/
RETRACT
ASSY.
4X 3/8-16 THREADED HOLES
FOR MOUNTING SUPPORT
ODF
ID
ISOLATION
VALVE
FULL PORT BALL (SHOWN)
OR GATE STYLE
(SEE SHEET 2)
WALL
NOTICE
INTEGRAL MOUNT
HEAD OPTION
FOR ACCURATE FLOW MEASUREMENT
THE CORRECT HOLE SIZE IN PIPE MUST BE:
3/4
(19mm)
INCH
DO NOT DRILL OVERSIZE
DO NOT TORCH CUT HOLE
RF FLANGE,
WELD FTG.,
STUDS, NUTS
& GASKET
ODV
ODH
PROBE INSERTED: PI
FORMULA FOR 'PI' = ID + WALL + ODV +
17.77 [451,4] FLANGED
PROBE RETRACTED: PR
FORMULA FOR 'PR' = 2x (ID + WALL + ODV) +
17.77 [451,4] FLANGED
OW
FL
NOTE: UNLESS OTHERWISE SPECIFIED
ALL INFORMATION IS BOTH (TYP) & GENERAL
TO STANDARD PRODUCT DESIGN
ALL PIPE SECTIONS SHOWN FOR REFERENCE ONLY
J.PAYLOR
DR.
BOULDER, COLORADO
10/4/05 TITLE DIMENSION DRAWING, MODEL 485 ANNUBAR
FLOWMETER (3051SFA, 3051CFA 2051CFA,
3095MFA) SENSOR SIZE 1 FLANGED / THREADED
FLO-TAP 150# - 600# ANSI
APPROVAL
DRAWING
TAGGING
SPECIALS
Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary
®
TYPE I
*UNLESS OTHERWISE SPECIFIED
DIMENSIONS IN INCHES (MM)
*ALL DIMENSIONS ARE NOMINAL
AND ARE FOR REFERENCE ONLY
FLANGED
MANUAL FLO-TAP
SENSOR SIZE 1
D.VERHAAGEN
1/9/06
SIZE
A
SCALE: NONE
DRAWING NO.
00485-1012
SHEET
1
OF
4
VL
VL
THREADED FULL PORT GATE VALVES
FLANGED FULL PORT GATE VALVES
FULL PORT GATE VALVES
VL
VL
THREADED FULL PORT BALL VALVES
FLANGED FULL PORT BALL VALVES
FULL PORT BALL VALVES
®
BOULDER, COLORADO
SIZE
A
FSCM.NO.
SCALE: NONE WT.
Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary
DRAWING NO.
00485-1012
SHEET
2
OF
4
3051S TRANSMITTER
EQUALIZER
VALVE
3051SFA, STD HARDWARE
TEMP WIDTH
WIDTH
FLOWMETER
HEIGHT
WIDTH
2051CFA
7.03
[178,5]
5.50
[139,7]
3051CFA
7.1
[181]
5.67
[144,0]
3051SFA
8.53
[216,7]
5.67
[144,0]
3095MFA
7.1
[181]
5.67
[144,0]
TEMP
WIDTH
10.09
[256,3]
HEIGHT
LOW PRESSURE
INSTRUMENT VALVE
®
HIGH PRESSURE INSTRUMENT VALVE
BOULDER, COLORADO
3051SFA SHOWN
SIZE
A
FSCM.NO.
SCALE: NONE WT.
Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary
DRAWING NO.
00485-1012
SHEET
3
OF
4
LOW-PRESSURE
INSTRUMENT
CONNECTION
HIGH-PRESSURE
INSTRUMENT
CONNECTION
ODH:
PROBE INSERTED: PI
FORMULA FOR 'PI' = ID + WALL + ODV +
16.96 [430,8] THREADED
PROBE RETRACTED: PR
FORMULA FOR 'PR' = 2x (ID + WALL + ODV) +
16.96 [430,8] THREADED
ODV
ISOLATION VALVE
THREADED FULL PORT
GATE VALVE SHOWN
FLOW
THREADED FLO-TAP WITH FULL PORT GATE VALVE
HORIZONTAL FLOW
REMOTE MOUNT INSTRUMENT CONNECTIONS
(NEEDLE VALVES SHOWN)
OW
FL
®
BOULDER, COLORADO
SIZE
A
FSCM.NO.
SCALE: NONE WT.
Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary
DRAWING NO.
00485-1012
SHEET
4
OF
4