PulseLife CW Tileable Array

PulseLife CW Tileable Array
PulseLife CW Tileable Array
Water-Cooled Horizontal Tileable Array
Features
• Compact design for end-to-end stacking
• Hard-solder indium-free die attach
• Simple, reliable, macro-channel water cooling
• Patented industry-leading AAA™ (Aluminum-free Active Area) epi
• >20,000 hours MTTF
Mechanical Specifications
Top View
6-32 Thread For
Power Connection (-)
41.1 mm
(1.62 in.)
6.3 mm
(0.25 in.)
53.8 mm
(2.12 in.)
6-32 Thread For
Power Connection (+)
3.81 mm
(0.15 in.)
8.89 mm
(0.35 in.)
19.6 mm
(0.77 in.)
Ø3.66 mm
(0.144 in.) Thru
16.76 mm
(0.66 in.)
20.32 mm
(0.8 in.)
9.63 ±0.12 mm
(0.379 ±0.005
Emitter Height
Side View
12.9 mm
(0.51 in.)
0.34 mm
(0.013 in.)
10.8 mm (0.425 in.)
Pitch 4X
53.18 mm (2.094 in.)
Emission Area
11.68 mm
(0.46 in.)
30.48 mm
(1.2 in.)
2X Ø3.18 mm (0.125 in.)
Water Channels
14.99 mm
(0.59 in.)
Bottom View
Superior Reliability & Performance
PulseLife™ CW Tileable Array
Water-Cooled Horizontal Tileable Array
CW Output Power, Total (W)
CW Output Power per Bar (W)
Center Wavelength1 (nm)
Wavelength Temperature Coefficient (nm/C)
Spectral Width2 (FWHM)(nm)
Fast Axis Divergence (FWHM)(deg.)
Slow Axis Divergence (FWHM)(deg.)
Operating Current (A)
Operating Voltage (V)
Threshold Current (A)
Recommended Operating Temp.3 (°C)
Recommended Operating Temp. Range4 (°C)
Storage Temperature Range4 (°C)
Water Flow Rate5 (l/min.)
Water Pressure Drop6 (psi)
Water Filter Size (µm)
Water Quality
Intended Operation Mode
5-Bar Arrays
200
40
807 ±2
0.28
<3
<35
<10
<51 (45 typ.)
<10.6 (10 typ.)
12 (typ.)
25
15 to 35
-40 to +70
>1.5
<30
<_100
Distilled or clean tap water
CW or QCW
Reverse Current (µA)
Reverse Voltage (V)
Internal Water Pressure (psi)
25
2
60
Device Specifications
Absolute Maximum Ratings
1
At rated power and operating temperature, with water flow 1.5 lpm per array.
At rated power and operating temperature.
Water inlet temperature.
4 In clean dry air; non-condensing environment.
5 Water flow rate should be maintained at 1.5 lpm or above.
6 Water pressure drop given above is required to maintain water flow rate of 1.5 lpm.
2
3
Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice.
Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered
by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976.
Coherent offers a limited warranty for all PulseLife arrays. For full details of this warranty coverage, please refer to the Service section
at www.Coherent.com or contact your local Sales or Service Representative.
www.Coherent.com
Printed in the U.S.A. MC-105-10-0M0510
Copyright © 2010 Coherent, Inc.
Coherent, Inc.
5100 Patrick Henry Drive
Santa Clara, CA 95054
phone (800) 527-3786
(408) 764-4983
fax
(408) 764-4646
e-mail [email protected]
Benelux +31 (30) 280 6060
China
+86 (10) 6280 0209
France +33 (0)1 6985 5145
Germany +49 (6071) 968 333
Italy
+39 (02) 34 530 214
Japan
+81 (3) 5635 8700
Korea
+82 (2) 460 7900
UK
+44 (1353) 658 833
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF