datasheet & brochure NS5
NS SERIES
One-touch machine management
» High-quality screen with 3-year warranty
»
Co n n e c t to a ny d ev i c e
»
‘Drag & Drop’ simplicity of Smart Active Parts
Total control at your fingertips
Omron’s NS series looks like a normal HMI, but
it is not. Designed on Smart Platform, the NS series
provides enhanced communication even across
multiple networks, to manage all devices in
a machine for true industrial machine management.
We provide functions to let you perform diagnoses
and maintenance to make your machine competitive
in an easy way. This is why we call it: one touch
Machine Management. And that’s why it’s more than
just an HMI terminal!
3AR
YAERRANTY
W
Outstanding connectivity
Used together with Omron PLCs and other fieldprogrammable devices, such as temperature controllers and
inverters, the NS series gives enhanced communication and
programming capabilities, even across multiple networks,
allowing you to manage all devices in your machine from
a single terminal.
A built-in USB connection enables simple and fast connection
of peripherals, while a built-in Ethernet interface allows fast
connection to multiple PLCs and computers.
The NS series is also capable of connecting to many nonOmron devices to give you total flexibility in managing
your machine.
Sysmac One
Machine management tool vs. HMI terminal
The NS HMI has, beside the generic HMI functions, many
other functions to be able to use the NS as a real machine
management tool. With the NS HMI you can configure,
commission, maintain and operate many Omron devices and
even third party devices. This means you can simple configure
some settings, display errors or statuses, up- and download
parameters all with the NS HMI terminal.
The NS HMI allows you to create and use the diagnostics
functions for many devices you need to manage your machine.
By providing diagnoses and maintenance functions on the
NS, Omron allows a full insight into the machine’s state and
the flexibility to quickly troubleshoot on-site with minimum of
work for the machine builder, system integrator or end-user.
Integrated Machine Management: Sysmac One series
The Sysmac One series combine an NS touch screen with
a powerful CJ1 PLC and the choice of different network
Proven reliability
interfaces in a compact housing occupying less panel space.
For over a decade Omron has been a global supplier
Complete transparency enables the PLC, network (including
of HMI solutions and high-reliability industrial touch-screen
field devices) and HMI to be accessed via a single port – a big
technology. Omron has supplied more than 500,000 pieces
advantage when servicing your machine remotely.
of HMI through more than 200 Omron Sales & Support offices
With the Sysmac One you get the best of both worlds:
world-wide, each offering after-sales support, service and
One touch Machine Management HMI and the flexible, fast
training in local languages.
and easiest logic controller in the market.
Smart Platform
Omron’s Smart Platform concept enables complete machine
and plant automation from one single platform without
having to worry about field buses, integration of various
software and above all without being locked into one
dominant supplier. Smart Platform will minimize the time
and effort you spend on automation.
http://smartplatform.info/
NS Series Portfolio
Advanced HMI – NS
Model
NS12
Display 12.1 inch TFT colour
NS10
NS8
NS5
NS5 Handheld
10.4 inch TFT colour
8.4 inch TFT colour
5.7 inch Monochrome or
STN/TFT colour
5.7 inch STN colour
640×480 pixels
640×480 pixels
320×240 pixels
320×240 pixels
Number of colours 256
(32,768 for image data)
256
(32,768 for image data)
256
(32,768 for image data)
Monochrome 16 greyscales, STN/TFT 256
colours
(STN 4096, TFT 32,768
for image data)
256 colours
(4096 colours for
image data)
Memory Size 60MB screen memory,
32,768 words + 32,768
bits internal memory and
8192 words + 8192 bits
retentative memory
60MB screen memory,
32,768 words + 32,768
bits internal memory and
8192 words + 8192 bits
retentative memory
60MB screen memory,
32,768 words + 32,768
bits internal memory and
8192 words + 8192 bits
retentative memory
60MB screen memory,
32,768 words + 32,768
bits internal memory and
8192 words + 8192 bits
retentative memory
60MB screen memory,
32,768 words + 32,768
bits internal memory and
8192 words + 8192 bits
retentative memory
Ethernet,
Controller Link,
Video input board
(RGB/Composite)
Ethernet,
Video input board
(RGB/Composite)
Ethernet
RS-232 or RS-422
communication
depending on cable
241×315×48.5
177×195×48.5
142×195×54
176×223×70.5
(excl. emergency
button)
Resolution 800×600 pixels
Options Ethernet,
Controller Link,
Video input board
(RGB/Composite)
Size in mm (HxWxD) 241×315×48.5
HMI & Control – SYSMAC One
Model
NSJ12
Display 12.1 inch colour TFT
Display Size / Resolution 246×184.5 mm
(800×600 pixels)
Control CJ1G-CPU45H;
60k-steps program memory,
128k-words data memory,
logic instruction time 0.04 µs
Communication DeviceNet Master/Slave or
PROFIBUS Master and
optional Ethernet interface
Expansion (1 board max.) Ethernet, Controller Link,
I/O extension
Size in mm (HxWxD) Without expansion unit
241×315×73.3
With expansion unit
241×315×89.3
4
4
NSJ10
NSJ8
NSJ5
10.4 inch colour TFT
8.4 inch colour TFT
5.7 inch colour TFT or STN
215.5×162.4 mm
(640×480 pixels)
170.9×128.2 mm
(640×480 pixels)
117.2×88.4 mm
(320×240 pixels)
CJ1G-CPU45H;
60k-steps program memory,
128k-words data memory,
logic instruction time 0.04 µs
CJ1G-CPU45H;
60k-steps program memory,
128k-words data memory,
logic instruction time 0.04 µs
CJ1G-CPU45H;
60k-steps program memory,
128k-words data memory,
logic instruction time 0.04 µs
CJ1M-CPU13;
20k-steps program memory,
32k-words data memory,
logic instruction time 0.04 µs
CJ1M-CPU13;
20k-steps program memory,
32k-words data memory,
logic instruction time 0.04 µs
DeviceNet Master/Slave or
PROFIBUS Master and
optional Ethernet interface
DeviceNet Master/Slave or
PROFIBUS Master and
optional Ethernet interface
DeviceNet Master/Slave or
PROFIBUS Master and
optional Ethernet interface
Ethernet, Controller Link,
I/O extension
Ethernet, Controller Link,
I/O extension
Ethernet, Controller Link,
I/O extension
Without expansion unit
241×315×73.3
With expansion unit
241×315×89.3
Without expansion unit
177×232×73.3
With expansion unit
177×232×89.3
Without expansion unit
195×142×79
With expansion unit
195×142×95
NS SERIES
Outstanding Connectivity
Save time on programming and designing with Smart Active Parts
Unlike conventional visualization objects, Smart Active Parts communicate, across multiple networks, with their corresponding devices. They can
be used to configure, commission, operate and maintain these devices, without a single line of code needed to be written in the PLC or the HMI.
This allows you to add powerful functionality to your application within minutes.
NS
Click and Configure in four steps.
1. Create a new project
Easy Access
2. Open the Smart Active
Parts Library
3. Choose a Smart Active Part
4. Configure the communication
settings
few minutes
Easy Access
Inverter
Temperature
Controllers
PLC
Vision
Sensor
260,000-colour
video input
CPU, I/O and Communication Units
Vision
Sensor
CPU Bus
Units
and
Special I/O
Units
Easy Access
Remote I/O
Temperature
Controllers
Temperature
Controllers
Remote I/O
Terminal
The NS-series HMI
makes it easy to connect
to the PLC and many
other devices and show
data data from them
without any PLC programming.
Easy-to-use Software
Servomotor
Servo Driver
Inverter
Servomotor
Servo Driver
Advanced Industrial Automation
NS SERIES
Inverter
With Smart Active Parts
you can support functions
to be performed on-site
without using Software
programs, like CX-Programmer or CX-Thermo.
55
Using Smart Active Parts: just a few simple steps
Dramatically reduces the effort required to create ladder programming and screens.
A library with more than 2,000 Smart Active Parts is available, which can directly access OMRON PLCs and other devices. You can drag & drop
Smart Active Parts in an application in just 4 simple steps.
With Smart Active Parts you can for instance monitor device errors in understandable text, donwload parameters to devices and check Network
statuses without the need for a computer with software tools.
Example screens using support tool objects (Tool Function SAP Library)
From
To
Computer support tools
PLC CPU Unit
monitoring
NCF Unit
screen
setting screen
DeviceNet
monitoring screen
The SAP library also provides PLC I/O Unit Troubleshooter SAPs
Troubleshooter Smart Active Parts are available
Troubleshooter SAP for a Position Control Unit
to troubleshoot specific PLC units. When an error occurs in an unit, the Troubleshooter SAP
provides an easy-to-understand explanation of
the cause of the error as well as which counter
measures to take to resolve the error.
In this way you can quickly resolve errors onsite even without using documentation.
Troubleshooter SAP for Basic I/O Unit
260,000-colour Video Display
Display the production steps on the HMI via optional video inputs!
Two kinds of video interfaces are available to connect to various applications. Provides compatibility with OMRON Vision Sensors (F150, F160,
and F250) in addition to video and CCD camera connections. The NS-series HMI contain some useful functions like capturing and browsing images
and operating the Console functions in the vision sensor.
NS
RGB/Video Input Unit
NS-CA001 Video Input Unit
Four video inputs or CCD
cameras can be connected
and up to four images can be
displayed simultaneously if
the image size is
320x240 pixels.
NS-CA002 RGB/Video Input Unit
There is an analog RGB input
terminal in addition to the two
video input terminals. Either
the video signals or the
analog RGB signal can be
displayed on the NS-series
RGB
HMI.
Console
Camera
6
6
Vision Sensor
NS-CA001
Console
Camera
NS-CA002
NS SERIES
Single Port Multi Access (SPMA)
The PLC program and screen data can be transferred from a single port!
With SPMA you can transfer the PLC program and HMI project data with one cable connection. It does not even matter if you connect first to HMI
or PLC, you can always transfer the data and keep on operating the HMI or PLC.
The HMI can transfer data across different network levels.
Computer (Serial/USB/Ethernet) Æ NS-series HMI (Ethernet) Æ PLC (Ethernet or Controller Link) Æ PLC
Stay connected.
CX-Programmer
The ladder program can be transferred.
NS
Serial/USB
NS
or Ethernet
PLC
PLC
Ethernet
Ladder program
Ethernet or Controller Link
Ladder program
SPMA significantly improves maintenance efficiency when the NS-series HMI and PLC are connected over longer distances.
Computer (Serial/USB/Ethernet) Æ PLC (Serial, Ethernet or Controller Link) Æ NS-series HMI
Note: SPMA can be used in CS/CJ-series PLCs with lot number 030201 or later.
CX-Designer
Serial
Stay connected.
The ladder program can be transferred.
PLC
NS
Serial
NS
NS
PLC
Screen data
Serial
Screen data
Screen data
Ethernet or Controller Link
Direct Connection to Temperature Controllers and Inverters
Connect OMRON Temperature Controllers and Inverters to the NS-series HMI.
OMRON Temperature Controllers can be connected directly to the NS-series HMI RS-232C port. Data does not pass through the PLC, so ladder
programming is not required. There are many SAPs in the Library for Temperature Controllers. Temperature Controller screens can be created
easily just by pasting objects from the SAP Library onto the screens.
The Omron inverters can also be connected to the NS-series HMI. This makes it easy to read and change parameters for the inverters without any
PLC programming.
RS-485 Serial Adapter
OMRON V1000 Inverters
CJ1W-CIF11
RS-422A Serial Adapter
Advanced Industrial Automation
NS SERIES
OMRON Temperature Controllers
77
Exceptional Functionality
Easy maintenance with the Ladder Monitor
The NS HMI (except for the NS5 series) has a Ladder Monitor built in
as a standard feature. A Ladder Monitor is an application that allows
you to monitor the ladder program in the CS/CJ series PLC. With the
Ladder Monitor you can monitor the execution status of the ladder program in the connected PLC without the need to use software (CX-Programmer). Many useful functions are provided with the Ladder Monitor
like viewing I/O comments, monitor and change values, search
addresses, easy navigation and capture ladder image.
Easily utilizing advanced functions
Data block (Recipe) function
Data blocks (recipe function) allow several numeric values and/or
character strings to be transferred to/from memory areas, such as PLC
data areas. Data blocks can be used to change the system’s production
setup even faster.
NS-series
Select product
B’s information and
set it in the PLC.
Communication drivers
The NS-series HMI can connect to several non-Omron devices. This
means the NS HMI can have communication on one port to an Omron
devices and on the second port to a non-Omron device. Contact Omron
for up-to-date information on the available communication drivers for
the NS HMI series.
CS/CJ-series
PLC
Data Block
Width
Height
Colour
Product A
100
52
Red
Product B
150
54
Blue
Product C
200
56
Yellow
Product D
300
62
Red
Product E
400
64
Blue
To other
equipment
Product B
Macro functions
The NS provide an extensive set of macro functions that can be used
to perform many different operations.
These functions allows the HMI to process screen display actions or
calculate some data, which was performed by PLC before. Also the
HMI project can be made more interactive using some macro functions
in combination with PLC memory.
Macro functions can be used with screen pages, functional objects, like
buttons and lamps or on specific timing operation.
8
8
In general we provide macro functions to perform the following actions
using Conditional and Logical operations:
• Convert and manipulate data
• Read/Write data to a device
• Perform string manipulation
• Perform screen/popup operations
• Store/retrieve data from CF
• Set date/time
• Influence Screen navigation
• Perform loop operation
NS SERIES
Trend Graphs & Data Logging
Easily log and display any data over time
A variety of graphing functions are built into the NS-series HMI, such
as the trend graph, which can log data over a longer period of time, and
the line graph, which can display overlapping graphs.
Logging data is stored as a CSV file in the Memory Card mounted in
the NS-series HMI. The data stored in the Memory Card can be read
or deleted from the screen.
A list of log files is retrieved
from the memory card and
shown in a popup menu.
Read file button
Log files can be saved automatically, just by selecting the Save the data periodically Option in the Data Log Setting Window.
LOG001.CSV 04/06/04 10:00
LOG002.CSV 04/06/05 10:00
LOG003.CSV 04/06/06 10:00
LOG004.CSV 04/06/07 10:00
LOG005.CSV 04/06/08 10:00
LOG006.CSV 04/06/09 10:00
LOG007.CSV 04/06/10 10:00
Memory
Card
Automatically saved
Logging data for each day (43,200 points)
is saved in the Memory Card in CSV format.
It is possible to make a one-week log
by automatically saving the data
seven times.
Suffixes are automatically added to
file names set in the CX-Designer.
Trend Graph Function
Data stored/logged by the PLC can be displayed in overlapping graphs, so a device's operation can be compared for evaluation and analysis. In
addition, up to 1,000 words of consecutive data can be displayed as a line graph, data can be displayed together, and any region can be magnified.
(1) Graphs can be superimposed.
Continuous Line Graph
A graph can be plotted in any position by specifying the X and Y coordinates of the vertices.
Also, the graph can be moved on the screen by
specifying the movements from the PLC.
(2) The display can be magnified.
PLC
D0000
X1
D0001
Y1
D0002
X2
Y
(X2, Y2)
(X3, Y3)
(X1, Y1)
Y2
X3
Y3
Advanced Industrial Automation
NS SERIES
X
Information in the PLC's format can be plotted
moment-by-moment.
99
Diverse Network possibilities to fit any application
The NS-series provide very strong networking skills. With serial NT-Link communications supporting both 1:1 and 1:N connections you can connect
multiple HMI's to the PLC. The NS-series HMI can also support communications with multiple PLCs and multiple HMI's through Controller Link and
Ethernet connections, so the network can be configured freely to match the requirements and scale of the application. In addition, using the NSRuntime makes it possible to monitor machine status and log data from the host.
Software for Machine Monitoring and
Data Logging
(sold separately)
3
Ethernet
Personal computer
NS-series
CS/CJ-series
PLC
2
1
Controller Link
4
Serial connection
Connections
across network
levels
1
CS/CJ-series
PLC
1
CS/CJ-series PLC
NS-series
CS/CJ-series
PLC
NS-series
NS-series
Serial
connection
Serial connection
1:1 NT Link or Host Link
NS:PLC = 1:1
NS:PLC = 1:2
Connecting with the PLC through port A or port B
NS-series
NS-series
PLC
PLC
PLC
1:N NT Link
NS:PLC ratio = 8:1 max.
Up to 8 NS-series can be connected to each of the PLC's RS-232C/RS-422A ports.
NS-series
NS-series
NS-series
NS-series
NS-series
NS-series
PLC
NS-AL002 Converter
(Converts between
RS-232C and RS-422A.)
10
10
NS SERIES
2
Controller Link Connection
The HMI can be connected to an OMRON Controller Link network by mounting a Controller Link Interface Unit.
NS-CLK21
NS Series
If a Controller Link connection is
used, data links can be configured
between PLCs and multiple
PLCs can be monitored from the
NS-series HMI screen.
3
PLC
PLC
PLC
· Baud rate
2 Mbps (500 m max.)
1 Mbps (800 m max.)
500 kbps (1 km max.)
· Max. number of nodes: 32 nodes
Ethernet Connection
When using the NS-series HMI with Ethernet you can connect to any Omron controller with an Ethernet port. Beside this you can also use a FTP
client to gather data from the NS and even transfer project data to different NS HMI terminals.
NS Series
Personal computer
PLC
4
PLC
NS Series
Trajexia motion controller
Connections across Different Network Levels
The NS-series HMI can connect to a variety of devices in the network, through as many as 3 network levels. For example, if SAP (Smart Active
Parts) are being used, an NS-series HMI connected by Ethernet can be used to monitor the information in a PLC connected through Controller
Link as well as the information in the DeviceNet Slaves connected to that PLC.
NS Series
NS Series
Ethernet
PLC
Seamless and
Program-less
Seamless and
Program-less
Controller Link
PLC
PLC
DeviceNet
Advanced Industrial Automation
NS SERIES
1111
User-Friendly Software
Integrated Simulation
Simulate the HMI program with the PLC program on your PC.
The integrated simulation function allows you to test the ladder program with the HMI progam in an interactive way. You can quickly make changes
and test the function to see if it works as desired. Therefore the integrated simulation function significantly increases debugging efficiency.
PLC program
HMI project
Ladder Program
Touch Panel
Interactive
Interactive
Programming with Symbols
Screens can be created even when addresses are unknown.
Screens can be created even if the addresses have not been determined. Addresses can be input as either names or actual addresses and the
addresses can be input from the symbol table after the addresses are determined.
The symbol table created in our PLC programming package, CX-Programmer can be shared with CX-Designer by simply dragging and dropping
them in the software.
Symbols input for addresses, which
have not yet been determined.
Addresses input as addresses
because addresses have been
determined
[Input from the Symbol Table]
Addresses are
input in the
symbol table after
the addresses
are determined.
12
12
NS SERIES
Multi-language Support
Easily export/import text to translate in many different international languages.
As the NS-series HMI support Unicode you can use many different languages from Asia and Europe. In runtime you can switch between 16 languages.
With CX-Designer it is very easy to export and import texts for translation as it is using CSV format. When you import a new language you can
even choose to apply the same label properties (e.g. font, colour, etc.) as an existing language.
NS Series
Multi-language CSV data
Support for
42 International
Languages
Import
ient!
Conven
Advanced functions
Remote machine servicing over the WWW
The NS HMI series have a web-interface built into the HMI terminal. The web-interface function allows you to see the local NS HMI screen, which
is also seen by the operator, remotely in any standard web browser without the need to install software on your PC. This makes it very easy to see
what is happening at the site where the machine is located. You can see the alarms and actual values and even operate the HMI from your remote
location.
The web-interface1) can run in a monitor mode, which allows you to only monitor certain screens, or it can run in the operation mode so that you
can operate the HMI terminal as if you where located at the machine.
You can also show all the files stored on the local CF card, e.g. log files created by the NS data logger, and open or download these files from your
remote location.
1)
Web-interface function will be delivered with CX-One v3.1
Advanced Industrial Automation
NS SERIES
13
13
NS-Runtime
Machine monitoring and reporting at the production site
Machine Viewer
The NS-Runtime software provides functions equivalent to the NS Series, and enables you to display information and perform operations for a
complete production line. NS-Runtime will run the NS project, created with CX-Designer, on Windows XP including the DyaloX Series. Beside the
existing NS functionality, the NS-Runtime also provides some additional functions explained in more detail below.
Data Logger
Data can be logged through background processing, with up to 160,000 points stored in one
file. The logged data is stored in CSV format,
and data can be displayed on data log graphs.
Example: 160,000 Points
Data can be logged for approximately 7.4 days,
assuming data is logged every two seconds for
12 hours a day. By using automatic file saving,
data logging can be continued even longer than
7.4 days.
Displays a PDF file
on a screen
Display documents
The display document function in NS-Runtime
makes it possible to show documents (e.g. PDF
file) in the screen itself. This is useful for maintenance instructions or reporting. You can even
show a different document every time an alarm
occurs.
Application Startup Function
Other applications can be
overlapped on the screen
data, and they can be
used at the same time
You can start any user application from NSRuntime by simply clicking a button. This allows
you to open documents like Excel or any other
software tool you need to use.
Wide Screen
Computer output can be displayed on another
wide-screen monitor.
XGA (1,024 x 768 dots) and up to a maximum
screen size of 3,840 x 2,400 is supported.
Alarms occurring in devices or the line can be
monitored.
NS Series
Personal computer
PLC
14
14
PLC
NS Series
PLC
NS SERIES
NSH5 Series
The NSH5 is the mobile version of the NS5 HMI. So it comes with the same strong HMI functions, but allows you to move around the machine with
the HMI in your hand. For this we provide the NSH5 with an extremely tough casing that can withstand severe shock and is also completely water
resistant.
USB
USB Slave
Memory
Card interface
OMRON
Memory Card
Function Keys
The NSH5 has 10 Function-keys.
F1, F2, F6, F7: Wired outputs
F3 to F5, F8 to F10: Communications outputs
3-Position Enable Switch
Increased safety with DPST-NO structure
(wired outputs).
Superior Shock Resistance
Consistent with JIS B 3502, IEC 61131-2
(drop shock).
Memory Card Interface and USB Slave
Connector.
Easily transfer screens or save logs at high speed
using a USB connection.
RS-232C
cable
UL-listed Cables
RS-422A
cable
Emergency Stop Switch
3PST-NC Structure
DPST-NC: Increase safety (wired outputs).
SPST-NC: Input to internal NSH5 memory, output
to a lamp for emergency stop switch operation, or
output via communications, e.g., to a PLC.
Water Resistance to IP65
The water-resistant structure is equivalent to IP65
on all surfaces.
HMI and Cable Sold Separately
Select the Cable according to the application
(RS-232C/RS-422A).
Loose wires or connector, UL connector,
3 m or 10 m.
RS-232C Connecting Cable for the NSH5
NSH5-232UL-3M (Length: 3 m)
RS-232C
PLC
RS-422A
PLC
RS-232C Connecting Cable for the NSH5
NSH5-232UL-10M (Length: 10 m)
RS-422A Connecting Cable for the NSH5
NSH5-422UL-10M (Length: 10 m)
Docking Station
Docking Station
connection
RS-232C
cable
RS-232C Connecting Cable for the NSH5
NSH5-232CN-3M (Length: 3 m)
RS422A
PLC
RS-232C Connecting Cable for the NSH5
NSH5-232CN-10M (Length: 10 m)
Options
Docking Station
The Docking Station is designed in a way that the emergency stop switch
line will not turn OFF to trigger the emergency stop circuit even if the
NSH5 is disconnected from the station. This eliminates the need for adding an external circuit. Power is disconnected via a key. You can connect a maximum of 15 Docking Stations to a PLC.
Visor
Installing a visor helps to protect the Emergency Stop Switch and
prevents improper operation from occurring inadvertently when the HMI
is laid down.
Advanced Industrial Automation
NS SERIES
15
15
Sysmac One Series
Integrated Machine Management: Sysmac One series
The Sysmac One series combine an NS touch screen with a powerful CJ1 PLC and the choice of different network interfaces in a compact housing
occupying less panel space. With the standard USB port you can program both the controller part and the graphical display. The Sysmac One
series are available in different screen sizes and two different controller types. The controller is running on a separate CPU so that you have the
best performance on both screen and controller. Another benefit of this is that the controller can continue operating even if the screen is accidentally
broken.
Display Section
5.7 Inches
Colour STN Colour TFT
Controller Section
(Designated by model
number suffix)
8.4 Inches
10.4 Inches
12.1 Inches
M3x
�
�
�
-
-
G5x
�
�
�
�
�
Main Differences in Specifications
•
•
•
•
•
•
I/O capacity: 640
User memory: 20 Ksteps
Expanded data memory: None
I/O capacity: 1,280
User memory: 60 Ksteps
Expanded data memory: 32 Kwords x 3
banks
Sysmac One Appearance
Expansion Unit interface
Expansion Unit
One Expansion
Unit
Controller Link Unit
Controller
Section
Display Section
I/O Control Unit
(The photo shows
the NSJ8 Controller.)
Ethernet Unit
USB port
Easy Maintenance using Troubleshooter function
Quickly see Errors and Statusses of Controller and Network device
The standard-equipped Troubleshooter contributes to solving problems during device startup and operation. When an error occurs, simply follow
the on-screen instructions to confirm the error details and quickly implement counter measures, without referring to the manual.
Your HMI application
Troubleshooter Menu
This button takes you directly back to
your HMI application.
16
16
NS SERIES
Expansion Units
For the Sysmac One series we have three different expansion units available. It is only possible to use one expansion unit on a single Sysmac
One model. Two expansion units are providing extra network possibilities on Controller Link and Ethernet. The third expansion unit allows you to
connect the standard CJ1 units to the Sysmac One model.
Controller Link Unit (NSJW-CLK21-V1)
High-speed, large-capacity data link
The PLC data link function can be used to provide a high-speed, large-capacity data link between Controllers over the Controller Link network.
I/O Control Unit (NSJW-IC101)
Easily connect Special I/O Units and CPU Bus Units
Used to mount Motion Control Units and other Special I/O Units or CPU Bus Units to the NSJ-series Controller, for excellent expandability.
I/O Control Unit
NSJW-IC101
Power Supply
Unit
I/O Interface Unit
CJ1W-II101
CJ-series Basic I/O Unit
CJ-series Special I/O Unit
CJ-series CPU Bus Unit
10 Units max.
I/O Connection Cable (CS1W-CN1
)
3 Racks max. (3 x 10 Units max.)
Note: Used to mount Motion Control Units and other Special I/O Units or CPU Bus Units to the NSJ-series Controller, for excellent expandability.
Ethernet Unit (NSJW-ETN21)
Full use of versatile Ethernet functions
The Ethernet expansion unit provides extra Ethernet functions like sending/receiving messages, using CMND instruction and sending/receiving
E-mails.
CS/CJ-series PLC
Ethernet Unit
NSJW-ETN21
•FINS communications
•FTP server
•E-mail
•SMTP clients, etc.
Ethernet 100BASE-TX
The error details are displayed.
The necessary counter measure is displayed.
Controller
Troubleshooter
Network
Troubleshooter
Advanced Industrial Automation
NS SERIES
17
17
Control Panel Standardization
By standardizing control panels based on SYSMAC One, design steps can be reduced and software assets can be reused to eliminate redundancy
and inconsistency all the way from the design stage to system startup.
Example of
Standardized System
Ethernet
Basic Module
Standardization
Standardization
Select module
for each machine.
Application Modules
Screen and
ladder program
modules can also
be used.
Software Modules
Display Section
Smart Active Parts
(SAP Library)
ID tag
Use smart
distributed I/O
Controller Section
Smart FB Library
18
18
NS SERIES
NS-series HMI:
Outstanding connectivity
Many of equipment can be
connected to the NS HMI and
Sysmac One Series in addition
to the variety of highly
compatible OMRON control
components.
(Picture represents backside of a SYSMAC One unit)
Memory card interface
(Display part)
Memory card interface
(Controller part)
CF
For application back up and
saving PLC data, etc.
RS-232C
Port C
DeviceNet or
PROFIBUS
CF
For screen captures, recipes and
saving data log, etc.
Single connection port on NS and SYSMAC One series
Available for NS HMI functions on NS and
SYSMAC One series
PC
RS-232C, DOS/V transfer cable
XW2Z-S002 (2m)
USB serial conversion cable
CS1W-CIF31
General purpose USB cable
PLC
WE70
Wireless
PC
RS-422A/485 conversion unit
CJ1W-CIF11 (~50m)
NS-AL002 (~500m)
PC
PLC
DeviceNet
PROFIBUS
RS-232C port B
USB Host cable (for printer)
NS-US22 (2m)
NS-US52 (5m)
RS-232C port A
Ethernet
USB slave
Printer
USB host
Only available on SYSMAC One series
Barcode reader
Serial
Printer
Serial
RS-422A/485 conversion unit
CJ1W-CIF11
NS-AL002
Temperature controller
E5_N, EJ1, etc.
PLC
RS-232C, NS-PLC connection cable
XW2Z-200T (2m)
XW2Z-500T (5m)
Barcode reader
PC
I/O terminals
RS-232C, DOS/V transfer cable
XW2Z-S002 (2m)
USB, serial conversion cable
CS1W-CIF31
Inverters
CIMR-V7/F7, etc.
Memory link, single board Computer, etc.
Temperature controller, E5_N, EJ1, etc.
GRT1 series
SmartSlice I/O
CompoWay/F(direct serial connection to HMI)
Inverter
RS-422A/485
Advanced Industrial Automation
NS SERIES
Other company´s equipments
non-Omron
equipment
19
19
Omron Europe B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 www.industrial.omron.eu
Austria
Tel: +43 (0) 2236 377 800
www.industrial.omron.at
Germany
Tel: +49 (0) 2173 680 00
www.industrial.omron.de
Portugal
Tel: +351 21 942 94 00
www.industrial.omron.pt
Turkey
Tel: +90 216 474 00 40
www.industrial.omron.com.tr
Belgium
Tel: +32 (0) 2 466 24 80
www.industrial.omron.be
Hungary
Tel: +36 1 399 30 50
www.industrial.omron.hu
Russia
Tel: +7 495 648 94 50
www.industrial.omron.ru
United Kingdom
Tel: +44 (0) 870 752 08 61
www.industrial.omron.co.uk
Czech Republic
Tel: +420 234 602 602
www.industrial.omron.cz
Italy
Tel: +39 02 326 81
www.industrial.omron.it
South-Africa
Tel: +27 (0)11 579 2600
www.industrial.omron.co.za
Denmark
Tel: +45 43 44 00 11
www.industrial.omron.dk
Netherlands
Tel: +31 (0) 23 568 11 00
www.industrial.omron.nl
Spain
Tel: +34 913 777 900
www.industrial.omron.es
Finland
Tel: +358 (0) 207 464 200
www.industrial.omron.fi
Norway
Tel: +47 (0) 22 65 75 00
www.industrial.omron.no
Sweden
Tel: +46 (0) 8 632 35 00
www.industrial.omron.se
France
Tel: +33 (0) 1 56 63 70 00
www.industrial.omron.fr
Poland
Tel: +48 (0) 22 645 78 60
www.industrial.omron.pl
Switzerland
Tel: +41 (0) 41 748 13 13
www.industrial.omron.ch
Authorised Distributor:
More Omron representatives
www.industrial.omron.eu
Control Systems
• Programmable logic controllers • Human-machine interfaces • Remote I/O
Motion & Drives
• Motion controllers • Servo systems • Inverters
Control Components
• Temperature controllers • Power supplies • Timers • Counters • Programmable relays
• Digital panel indicators • Electromechanical relays • Monitoring products • Solid-state relays
• Limit switches • Pushbutton switches • Low voltage switch gear
Sensing & Safety
• Photoelectric sensors • Inductive sensors • Capacitive & pressure sensors • Cable connectors
• Displacement & width-measuring sensors • Vision systems • Safety networks • Safety sensors
• Safety units/relay units • Safety door/guard lock switches
KPP_NS_EN_INT01
Although we strive for perfection, Omron Europe BV and/or its subsidiary and affiliated companies do not warrant
or make any representations regarding the correctness or completeness of the information described in this document.
We reserve the right to make any changes at any time without prior notice.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF