EMQ-IGS-20040MT v1.0
L2+ Multi-Port Full Gigabit Managed Ethernet Switch
IGS-10020MT / IGS-10020PT / IGS-10020HPT /
IGS-10080MFT / IGS-20040MT
Quick Installation Guide
Table of Contents
1. Package Contents........................................................................................ 3
2.Requirements.............................................................................................. 4
3. Wiring the Power Inputs............................................................................... 5
4. Terminal Setup............................................................................................ 8
5. Logon to the Console................................................................................... 9
6. Configuring IP address................................................................................10
7. Starting Web Management..........................................................................13
8. Resetting the Switch to Default ..................................................................16
9. Customer Support......................................................................................18
1.Package Contents
Thank you for purchasing PLANET L2+ Industrial Managed Switch, IGS-10020
Series / IGS-10080MFT / IGS-20040MT. The descriptions of these models are as
follows:
IGS-10020MT :
Industrial 8-Port 10/100/1000T +
2-Port 100/1000X SFP Managed Switch
IGS-10020PT :
Industrial 8-Port 10/100/1000T 802.3af PoE +
2-Port 100/1000X SFP Managed Switch
IGS-10020HPT :
Industrial 8-Port 10/100/1000T 802.3af/at PoE +
2-Port 100/1000X SFP Managed Switch
IGS-10080MFT :
Industrial 8-Port 100/1000X SFP +
2-Port 10/100/1000T Managed Switch
IGS-20040MT :
Industrial 16-Port 10/100/1000T +
4-Port 100/1000X SFP Managed Switch
“Industrial Managed Switch” mentioned in this Quick Installation Guide refers
to the above five models.
Open the box of the Industrial Managed Switch and carefully unpack it. The
box should contain the following items:
zz The Industrial Managed Switch x 1
zz Quick Installation Guide x 1
zz DIN Rail Kit x 1
zz Wall Mounting Kit x 1
zz DB9 to RJ45 Interface RS232 Console Cable x 1
(For IGS-10020PT/IGS-10020HPT/IGS-10080MFT/IGS-20040MT)
zz Dust Cap (Please refer to the table below)
RJ45 Dust Cap
SFP Dust Cap
IGS-10020MT
8
2
IGS-10020PT
9
2
IGS-10020HPT
9
2
IGS-10080MFT
3
8
IGS-20040MT
17
4
3
If any of these are missing or damaged, please contact your dealer immediately. If
possible, retain the carton including the original packing materials to enable you to
repack the product in case there is a need to return it to us for repair.
2.Requirements
The Industrial Managed Switch provides remote login interface for management
purposes. The following equipment is necessary for further management:
 Workstation is installed with Ethernet NIC (Network Interface Card)
 Choice of Internet browsers includes Windows XP/2003, Vista, Windows 7, MAC
OS X, Linux, Fedora, Ubuntu or other platforms compatible with TCP/IP protocols.
 The above workstation is installed with Web browser and JAVA runtime environment plug-in.
 Ethernet Port connection
 Use standard network (UTP) cables with RJ45 connectors.
Note
4
It is recommended to use Internet Explore 7.0 or above to access
the Industrial Managed Switch.
3.Wiring the Power Inputs
The Upper Panel of the Industrial Managed Switch indicates a DC inlet power
socket and consists of one terminal block connector within 6 contacts. Please follow
the steps below to insert the power wire.
1.Insert positive / negative DC power wires into contacts 1 and 2 for Power 1, or
5, and 6 for Power 2.
 IGS-10020MT: DC 12~48V, AC 24V
Input
DC 12V~48V, AC 24V
V1-
V2- V2+
V1+
PWR1
Fault
PWR2
Figure 3-1: IGS-10020MT Upper Panel
 IGS-10020PT / IGS-10020HPT: DC 48V
Figure 3-2: IGS-10020PT / IGS-10020HPT Upper Panel
5
 IGS-10080MFT: DC 12~48V, AC 24V
V2- V2+
V1- V1+
[email protected]
PWR2
Fault
PWR1
Input DC 12V~48V
Figure 3-3: IGS-10080MFT Upper Panel
 IGS-20040MT: DC 12~48V, AC 24V
DI 0 DI 1 DO 0 DO 1 GND GND
DC1
Fault
DC2
Input DC 12-48V
AC 24V
Figure 3-4: IGS-20040MT Upper Panel
6
Tighten the wire-clamp screws for preventing the wires from loosening.
1
2
Power 1
+
-
Note
3
4
5
6
Power 2
+
-
The wire gauge for the terminal block should be in the range from
12 to 24 AWG.
7
4.Terminal Setup
To configure the system, connect a serial cable to a COM port on a PC or notebook
computer and to RJ45 type serial (console) port of the Managed Industrial Switch.
The console port of the Industrial Managed Switch is DCE already, so that you can
connect the console port directly through PC without the need of null modem.
IGS Industrial Managed Switch
PC / Workstation
with
Terminal emulation software
IP Address:
192.168.0.100
RJ45 to DB9 RS-232 Cable
Serial Port
A terminal program is required to make the software connected to the IGS
Industrial Managed Switch. Windows’ Hyper Terminal program may be a good
choice. The Hyper Terminal can be accessed from the Start menu.
1.Click START, then Programs, Accessories and then Hyper Terminal.
2.When the following screen appears, make sure that the COM port should be
configured as:
8
 Baud
: 115200
 Parity
: None
 Data bits
: 8
 Stop bits
: 1
 Flow Control
: None
5.Logon to the Console
Once the terminal has been connected to the device, power on the Industrial
Managed Switch and the terminal will display “running testing procedures”.
Note
1. There are four switches with RJ45 type console connector. (IGS10020PT/IGS-10020HPT/IGS-10080MFT/IGS-20040MT)
2. Let’s take IGS-20040MT for example.
When the following dialog box shown in Figure 5-1 appears, please enter the
factory default user name “admin” and password “admin”.
User name: admin
Password: admin
Figure 5-1: Console Login screen
Note
1. For security reason, please change and memorize the new password after this first setup.
2. Only accept command in lowercase letter under console interface.
9
6.Configuring IP address
The Industrial Managed Switch is shipped with default IP address shown below:
IP Address: 192.168.0.100
Subnet Mask: 255.255.255.0
To check the current IP address or modify a new IP address for the Switch, please
use the procedures as follows:
 Display of the current IP Address
1.At the “#” prompt, enter “show ip interface brief”.
2.The screen displays the current IP address shown in Figure 5-1.
Figure 6-1: IP Information Screen
10
 Configuration of the IP Address
3.At the “#” prompt, enter the following command and press <Enter> as shown
in Figure 5-2.
IGS-20040MT# configure terminal
IGS-20040MT (config)# interface vlan 1
IGS-20040MT (config-if-vlan)# ip address 192.168.1.100 255.255.255.0
The previous command would apply the following settings for the Industrial
Managed Switch.
IP Address: 192.168.1.100
Subnet Mask: 255.255.255.0
Figure 6-2: Configuring IP Address Screen
4.Repeat step 1 to check if the IP address is changed.
11
 Store the current switch configuration
5.At the “#” prompt, enter the following command and press <Enter>.
# copy running-config startup-config
Figure 6-3: Saving Current Configuration Command Screen
If the IP is successfully configured, the Industrial Managed Switch will apply the
new IP address setting immediately. You can access the Web interface of the
Industrial Managed Switch through the new IP address.
Note
12
If you are not familiar with the console command or the related
parameter, enter “help” anytime in console to get the help
description.
7.Starting Web Management
The following shows how to start up the Web Management of the Industrial
Managed Switch. Note the Industrial Managed Switch is configured through an
Ethernet connection. Please make sure the manager PC must be set on the same
IP subnet address.
For example, the default IP address of the Industrial Managed Switch is
192.168.0.100, then the manager PC should be set at 192.168.0.x (where x
is a number between 1 and 254, except 100), and the default subnet mask is
255.255.255.0.
IGS Industrial Switch
RJ45/UTP-Cable
IP Address:
192.168.0.x
IP Address:
192.168.0.100
Figure 7-1: IP Management Diagram
Logging in the Industrial Managed Switch
1.Use Internet Explorer 7.0 or above for Web browser and enter IP address
http://192.168.0.100 (the factory-default IP address) to access the Web
interface.
2.When the following dialog box appears, please enter the default user name
“admin” and password “admin” (or the password you have changed before) as
shown in Figure 7-2.
Default IP Address: 192.168.0.100
Default User Name: admin
Default Password: admin
13
Figure 7-2: Login Screen
3.After entering the password, the main screen appears as shown in Figure 7-3.
Figure 7-3: Web Main Screen of Industrial Managed Switch
14
4.The Switch Menu on the left of the Web page lets you access all the functions
and status the Industrial Managed Switch provides.
Now, you can use the Web management interface to continue the Switch
management. Please refer to the user manual for more.
Note
For security reason, please change and memorize the new password after this first setup.
15
8.Resetting the Switch to Default
To reset the IP address to the default IP Address “192.168.0.100” and the
user password to factory default mode (default password is admin), press the
hardware reset button on the front panel for about 10 seconds. After the device is
rebooted, you can login the management Web interface within the same subnet of
192.168.0.xx and default password. Be noted that all the previous setups will be
disappeared after the factory default reset is made.
P1
P2 FAULT
Ring
9
10
R.O.
LNK
ACT
1000 LNK/ACT 1000 LNK/ACT
MiniGBIC
9
10
100/1000X SFP
Reset Button
LNK
RESET
ACT
1000
Figure 8-1: IGS-10020MT Reset Button
Console
P1 P2 FAULT
Ring R.O.
115200,N,8,1
9
10
LNK
ACT
1000 LNK/ACT 1000 LNK/ACT
9
10
100/1000X SFP
Reset Button
RESET
LNK
ACT
PoE In-Use
Figure 8-2: IGS-10020PT
/ IGS-10020HPT
7
8 Reset Button
5
6
3
4
16
Reset Button
Figure 8-3: IGS-10080MFT Reset Button
Reset Button
RESET
P1
P2 FAULT
Ring R.O.
1
2
3
4
5
6
Console
17
Figure 8-4: IGS-20040MT Reset Button
17
9.Customer Support
Thank you for purchasing PLANET products. You can browse our online FAQ
resource on PLANET web site first to check if it could solve your issue. If you need
more support information, please contact PLANET switch support team.
PLANET online FAQ :
http://www.planet.com.tw/en/support/faq.php
Switch support team mail address :
[email protected]
IGS-10020MT / IGS-10020PT / IGS-10020HPT / IGS-10080MFT / IGS-20040MT
User’s Manual :
http://www.planet.com.tw/en/support/download.php?type1=22153&model=&type=3
(Please select your switch model name from Product Model drop down menu)
Copyright © PLANET Technology Corp. 2014.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.
18
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement