Terminal Block Connectors

Terminal Block Connectors
Han® Terminal Block Connectors
Contents
Page
Details of the Han® Terminal block connector . . . . . . . . . . . . . . . . . . . . . . . . 08.02
Technical characteristics Han D® AV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 08.04
Han D® AV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 08.05
Technical characteristics Han D® AV Distributor . . . . . . . . . . . . . . . . . . . . . . 08.06
Han D® AV Distributor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 08.07
Technical characteristics Han E® AV / Han® ES AV . . . . . . . . . . . . . . . . . . . 08.08
Han E® AV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 08.09
Han® ES AV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 08.10
Han® Terminal block connectors accessories . . . . . . . . . . . . . . . . . . . . . . . . 08.11
Han
AV
08
.
01
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Han D® AV
Possibilities in switch cabinet
Left or right hand mounting in the switch cabinet,
therefore allows use of the same pre-prepared
interface cable
Details
The terminal block connectors can be supplied for left hand or right hand
applications. Hence the ground and connecting terminal for contact no. 1 will
always be accessible from above in both types of installation.
left hand
version
Distributor
Internal use on standard rails in the switch
cabinet in conjunction with Han-Snap®
Han
AV
versions for rail
mounting
right hand
version
Terminal block
connector
Han D® AV
Distributor
Distributor lockable on standard rails
or mountable
at terminal block connector Han D® AV
Assembly of terminal block connectors
Terminal block connectors can be mounted
from the inside of the switch cabinet
into standard bulkhead housings.
Therefore pre-assembly is possible.
Standard bulkhead housing
Identification
08
.
02
The individual terminals have the same identification as on the mating face. In addition each circuit
may be separately labelled with identification strips
fitted in the adjacent slots.
Terminal block connector Han D® AV
Counterparts
For suitable mating inserts of serie Han D® with crimp terminal please refer
to the chapter 02.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Han E® AV / Han® ES AV
Possibilities in switch cabinet
Left or right hand mounting in the switch cabinet,
therefore allows use of the same pre-prepared
interface cable
Details
The terminal block connectors can be supplied for left hand or right hand
applications. Hence the ground and connecting terminal for contact no. 1 will
always be accessible from above in both types of installation.
left hand
version
Terminal block connector
Han E® AV,
Han® ES AV
Internal use on standard rails in the switch
cabinet in conjunction with Han-Snap®
right hand
version
versions for rail
mounting
Han
AV
Assembly of terminal block connectors
Male or female insert
Housings bulkhead mounting
Standard bulkhead housing
Terminal block connector Han E® AV
The terminal block connector is fixed in the standard bulkhead housing in the normal way.
Han E® AV and Han® ES AV with 16 and 24 pins
can be mounted from the inside of the switch cabinet into standard bulkhead housings. Therefore
pre-assembly is possible.
Identification
The individual terminals have the same identification as on the mating face. In addition each circuit
may be separately labelled with identification strips
fitted in the adjacent slots.
Counterparts
For suitable mating inserts of series Han E® and Han® ES with screw, cageclamp or crimp terminals please refer to the chapter 03.
08
.
03
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Han D® AV Features
Technical characteristics
• For left hand or right hand applications available
• PE and connecting terminal for contact no.1 are at
the top in both types of installation
• Mountable in standard bulkhead housing and on
standard rails by using of fixing elements
• Screw terminal with integrated wire protection
Specifications
Current carrying capacity
The current carrying capacity of the connectors is limited by the
thermal load capability of the contact element material including
the connections and the insulating parts. The derating curve
is therefore valid for currents which flow constantly (non-intermittent) through each contact element of the connector evenly,
without exceeding the allowed maximum temperature.
Measuring and testing techniques according to
DIN EN 60 512-5
Han
AV
Han® 40 D AV
Approvals
Inserts
Number of contacts
40, 64 + PE
Electrical data
acc. to EN 61 984
Rated current
Rated voltage
Rated impulse voltage
Pollution degree
10 A 250 V 4 kV 3 10 A
250 V
4 kV
3
Pollution degree 2 also
10 A 230/400 V 4 kV 2 Rated voltage
acc. to UL/CSA
600 V
Insulation resistance
≥ 1010 Ω
Materialpolycarbonate
-40 °C ... +125 °C
Limiting temperatures
Flammability acc. to UL 94
V0
Mechanical working life
- mating cycles
≥ 500
Contacts
Material
Surface
- mating side
- termination side
Contact resistance
Operating current
DIN EN 60 664-1
DIN EN 61 984
,
Screw terminal
- Wire gauge1)
- AWG
- Tightening/test torque
copper alloy
3 µm Ag
tin plated
≤ 4 mΩ
0.2 ... 2.5 mm²
24 ... 14
0.5 Nm
Ambient temperature
Han® 64 D AV
Hoods/Housings
see chapter 30 / 31
Operating current
Identification strips
Ambient temperature
08
.
04
➀ wire gauge: 0.75 mm²
➁ wire gauge: 1.5 mm²
1)
the following identifcation strips may be used
HARTING
09 21 000 9971
Murrplastik
KPX 5/10-5
Weidmüller
DEK 5
Multi-Contour (MK)
4K-DST 5
DS 5
Phoenix
ZB 5
WAGO
WSB 5
KWI 5/10
Murrplastik
KWI 5/10-5
Single-Contour
KWI 8,6-5
(SK)
Wieland
9705 A/5/10
WAGO
Mini-WSB
geometric wire gauge
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Han D® AV
250 V 10 A
Number of contacts
40, 64 +
Identification
Number of
contacts
Part number
Male insert
Female insert
Drawing
Dimensions in mm
Left hand version
Multi contour (MK)
40
64
09 21 040 4601
09 21 064 4601
09 21 040 4701
09 21 064 4701
Han
AV
Left hand version
Single contour (SK)
40
64
09 21 040 4602
09 21 064 4602
09 21 040 4702
09 21 064 4702
40
64
09 21 040 4611
09 21 064 4611
09 21 040 4711
09 21 064 4711
40
64
09 21 040 4612
09 21 064 4612
09 21 040 4712
09 21 064 4712
Right hand version
Multi contour (MK)
Right hand version
Single contour (SK)
Han® 40 D AV
Han® 64 D AV
➀ Contact arrangement for male insert
➁ Contact arrangement for female insert
a
51
81.5
b
77.5
104
Stock items in bold type
08
.
05
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Han D® AV Distributor Features
Technical characteristics
• Easy mounting direct adjacent to terminal block
connector Han D® AV
• By using of fixing elements mountable on standard
rails
• Screw terminal with integrated wire protection
Specifications
Approvals
Distributor
Number of contacts
Mounting example
Distributor
on standard rail
Distributor
with teminal block connector
Han D® AV
Han
AV
DIN EN 60 664-1
DIN EN 61 984
,
20, 2 x 10, 4 x 4
Electrical data
acc. to EN 61 984
16 A 400/690 V 6 kV 3 Rated current
16 A
Rated voltage conductor - ground 400 V
Rated voltage conductor - conductor 690 V
6 kV
Rated impulse voltage
3
Pollution degree
Pollution degree 2 also
16 A 480/830 V 6 kV 2 Rated voltage
acc. to UL/CSA
600 V
≥ 1010 Ω
Insulation resistance
Materialpolycarbonate
Limiting temperatures
-40 °C ... +125 °C
Flammability acc. to UL 94
V0
Mechanical working life
- mating cycles
≥ 500
Contacts
ContactsMaterial
Surface
- termination side
Screw terminal
- Wire gauge1)
- AWG
- Tightening/test torque
copper alloy
tin plated
0.2 ... 2.5 mm²
24 ... 14
0.5 Nm
Identification
The individual terminals have the same identification as on the
mating face. In addition each circuit may be separately labelled
with identification strips fitted in the adjacent slots.
Identification strips
the following identification strips may be used
HARTING
09 21 000 9971
Murrplastik
KPX 5/10-5
4K-DST 5
Phoenix
ZB 5
DS 5
08
.
06
1)
geometric wire gauge
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Han D® AV Distributor
400/690 V 16 A
Number of contacts
20, 2x10, 4x4
Identification
Terminals
Part number
Drawing
Dimensions in mm
Distributor
with screw terminals
Han
AV
20
09 42 020 0111
2x10
09 42 020 0121
4x4
09 42 020 0131
Optionally mountable on terminal block connectors
Han D® AV
Stock items in bold type
08
.
07
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Han E® AV / Han® ES AV Features
Technical characteristics
• For left hand or right hand applications available
• PE and connecting terminal for contact no.1 are at
the top in both types of installation
• Mountable in standard bulkhead housing and on
standard rails by using of fixing elements
• Screw terminal with integrated wire protection at
Han E® AV
• Cage-clamp terminal at Han® ES AV
Specifications
Current carrying capacity
The current carrying capacity of the connectors is limited by the
thermal load capability of the contact element material including
the connections and the insulating parts. The derating curve
is therefore valid for currents which flow constantly (non-intermittent) through each contact element of the connector evenly,
without exceeding the allowed maximum temperature.
Measuring and testing techniques according to
DIN EN 60 512-5
6, 10, 16, 24, 32 (2 x 16),
48 (2 x 24) + PE
Electrical data
acc. to EN 61 984
Rated current
Rated voltage
Rated impulse voltage
Pollution degree
16 A 500 V 6 kV 3 16 A
500 V
6 kV
3
Pollution degree 2 also
16 A 400/690 V 6 kV 2 Rated voltage
acc. to UL/CSA
Rated current acc. to UL/CSA
600 V
12 A (only for Han® ES)
Material
Surface
- mating side
- termination side
Contact resistance
copper alloy
3 µm Ag
tin plated
≤ 4 mΩ
Screw terminal
- Wire gauge1)
- AWG
- Tightening/test torque
0.2 ... 2.5 mm²
24 ... 14
0.5 Nm
Cage clamp terminal
- Wire gauge1)
- AWG
0.14 ... 2.5 mm²
26 ... 14
Operating current
Identification strips Han E® AV
Ambient temperature
➀ Han® 6 E AV / Han® 6 ES AV
➁ Han® 10 E AV / Han® 10 ES AV
➂ Han® 16 E AV / Han® 16 ES AV
➃ Han® 24 E AV / Han® 24 ES AV
1)
Number of contacts
Contacts
Ambient temperature
08
.
08
Inserts
Insulation resistance
≥ 1010 Ω
Materialpolycarbonate
Limiting temperatures
-40 °C ... +125 °C
V0
Flammability acc. to UL 94
Mechanical working life
- mating cycles
≥ 500
Operating current
Han
AV
Approvals
DIN EN 60 664-1
DIN EN 61 984
,
the following identification strips may be used
HARTING (6x10)
09 33 000 9971
Murrplastik
KPX 6/10
Multi contour (MK)
Weidmüller
DEK 6,5
Phoenix
4K-DST 6
WAGO
WSB
Murrplastik
KWI 6/10
Single contour (SK) Wieland
9705 A/6,7
WAGO
Mini-WSB
Identification strips Han® ES AV
the following identification strips may be used
HARTING (6x15)
09 33 000 9973
Murrplastik
KWI 6/15
Single contour (SK)
Wieland
9705 A/6.7
WAGO
Mini-WSB
geometric wire gauge
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Han E® AV
500 V 16 A
Number of contacts
6, 10, 16, 24 +
Identification
Number of
contacts
Part number
Male insert
Female insert
Drawing
Dimensions in mm
Left hand version
Multi contour (MK)
6
10
16
24
09 33 006 4625
09 33 010 4625
09 33 016 4625
09 33 024 4625
09 33 006 4725
09 33 010 4725
09 33 016 4725
09 33 024 4725
Han
AV
Left hand version
Single contour (SK)
6
10
16
24
09 33 006 4626
09 33 010 4626
09 33 016 4626
09 33 024 4626
09 33 006 4726
09 33 010 4726
09 33 016 4726
09 33 024 4726
6
10
16
24
09 33 006 4635
09 33 010 4635
09 33 016 4635
09 33 024 4635
09 33 006 4735
09 33 010 4735
09 33 016 4735
09 33 024 4735
6
10
16
24
09 33 006 4636
09 33 010 4636
09 33 016 4636
09 33 024 4636
09 33 006 4736
09 33 010 4736
09 33 016 4736
09 33 024 4736
Right hand version
Multi contour (MK)
Right hand version
Single contour (SK)
Han® 6 E AV
Han® 10 E AV
Han® 16 E AV
Han® 24 E AV
➀ Contact arrangement for male insert
➁ Contact arrangement for female insert
a
20
34
54
81
b
44
57
77.5
104
Stock items in bold type
08
.
09
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Han® ES AV
500 V 16 A
Number of contacts
6, 10, 16, 24 +
Identification
Number of
contacts
Part number
Male insert
Female insert
Drawing
Dimensions in mm
Left hand version
Single contour (SK)
Han
AV
6
10
16
24
09 33 006 4629
09 33 010 4629
09 33 016 4629
09 33 024 4629
09 33 006 4729
09 33 010 4729
09 33 016 4729
09 33 024 4729
6
10
16
24
09 33 006 4639
09 33 010 4639
09 33 016 4639
09 33 024 4639
09 33 006 4739
09 33 010 4739
09 33 016 4739
09 33 024 4739
Right hand version
Single contour (SK)
Han® 6 ES AV
Han® 10 ES AV
Han® 16 ES AV
Han® 24 ES AV
08
.
10
➀ Contact arrangement for male insert
➁ Contact arrangement for female insert
a
20
34
54
81
b
44
57
77.5
104
Stock items in bold type
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Accessories Identification
Part number
Drawing
Dimensions in mm
Fixing element
for
Terminal block connector
Han D® AV,
Distributor
09 33 000 9928
Terminal block connector Han D® AV
Han
AV
Fixing element
C-rail
DIN EN 60 715-C 30
G-rail
DIN EN 60 715-G 32
Rail
DIN EN 60 715-35 x 7.5
or -35 x 15
Fixing element
for
Terminal block connector
Han E® AV,
Han® ES AV
Terminal block connector Han E® AV
09 33 000 9929
Fixing element
C-rail
DIN EN 60 715-C 30
G-rail
DIN EN 60 715-G 32
Rail
DIN EN 60 715-35 x 7.5
or -35 x 15
There are moulded slots at the rear of the terminal block connectors and distributors to accept the fixing elements. When used these elements, for example,
can be used to secure the connectors inside the switch cabinets on standard
rails.
For mounting
Han® 6 E AV, Han® 6 ES AV = 1 fixing element
Han 10/16/24 E AV, Han® 10/16/24 ES AV = 2 fixing elements
Han® 40/64 D AV = 2 fixing elements
Distributor = 1 fixing element
®
Stock items in bold type
08
.
11
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Accessories Identification
Part number
Drawing
Dimensions in mm
Identification strips
88 pieces in one block
(MK-contour)
5 mm width
09 21 000 9971
for Terminal block connector Han D® AV
and Distributor
10 mm long
09 33 000 9971
for Terminal block connector Han E® AV
15 mm long
09 33 000 9973
for Terminal block connector Han® ES AV
10 mm long
Han
AV
Identification strips
64 pieces in one block
(MK-contour)
6 mm width
Adapter for
Han E® AV
to fit identification
strips (SK-contour)
Han® 6 E AV
09 33 000 9964
Han® 10 E AV
09 33 000 9965
Han® 16 E AV
09 33 000 9966
Han® 24 E AV
09 33 000 9967
Han® 6 E AV
Han® 10 E AV
Han® 16 E AV
Han® 24 E AV
08
.
12
a
26.8
40.2
60.3
87.4
Stock items in bold type
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com