SECTION 6 ITEM 3310 DATED JUNE 1, 2007 INSTRUCTION, INSTALLATION, MAINTENANCE AND REPAIR MANUAL MODEL 3310 IMPORTANT NOTE TO INSTALLER: This manual contains important information about the installation, operation and safe use of this product. This information should be given to the owner/operator of this equipment. APPLICATIONS: The 3310 Series pumps are frame mounted or close coupled. They feature high efficiency, rugged construction, foot mounted volutes with back pullout power frames, center drop out spacer coupling (optional) and re-greaseable ball bearings. The pump’s bronze fitted construction is suitable for unheated domestic and fresh water, condensate, boiler feed water, pressure boosting and hydronic coding and/or heating. ATTENTION: SAFETY WARNINGS: Read and understand all warnings before installation or servicing pump. OPERATIONAL LIMITS: * Maximum Operating Pressure: 290 psi at Temperatures to 300 F (148°C) O * See ASTM A126/ANSI B16.1 for pressure/temperature ratings of flanges. ELECTRICAL SAFETY: Warning: Electrical Shock Hazard All electrical connections are to be made by a qualified electrician in accordance with all codes and ordinances. Failure to follow these instructions could result in serious personal injury, death or property damage. Warning: Electrical Overload Hazard Insure all motors have properly sized overload protection. Failure to follow these instructions could result in serious personal injury, death or property damage. Warning: Sudden Start-Up Hazard Disconnect and lockout power source before servicing. Failure to follow these instructions could result in serious personal injury, death or property damage. 6 HIGH TEMPERATURE SAFTEY: Warning: Hot Surface Hazard If pumping hot water, insure guards or proper insulation is installed to protect against skin contact with hot piping or pump components. Failure to follow these instructions could result in serious personal injury, death or property damage. Warning: Spraying Water Hazard When servicing pump replace all gaskets and seals. Do not re-use old gaskets or seals. Failure to follow these instructions could result in serious personal injury, death or property damage. HIGH PRESSURE SAFTEY: Warning: High Pressure Hazard The pump is rated at a maximum of 290 psi at 300°F. Do not exceed this pressure. Install properly sized pressure relief valves in system. Failure to follow these instructions could result in serious personal injury, death or property damage. Warning: Expansion Hazard Water expands when heated. Install properly sized thermal expansion tanks and relief valves. Failure to follow these instructions could result in serious personal injury, death or property damage. INSTALLATION: Read and understand all safety warnings at the beginning of the manual before beginning installation or any repair work. PUMP LOCATION. You have probably spent considerable time planning where your pump will be located. However, you may have overlooked some factor that may affect pump operation or efficiency. The pump should be located as close to the liquid source as possible so that the suction line can be short and direct. It should be located in a clean, open area, where it is easily accessible for inspection, disassembly, and repair. Pumps installed in dark, dirty areas or in cramped locations are often neglected which can result in premature failure of both the pump and the driver. MODEL 3310 3310 series pumps may be mounted horizontally or vertically. Install isolating valves on each side of pump so pump maintenance can be performed without draining the system. Special mounting requirements may be required if the pump is to be mounted near a noise or vibration sensitive area. The installation must be evaluated to ensure that the net positive suction head available (NPSHA) meets or exceeds the net positive suction head required (NPSHR), as stated by the pump performance curve. FOUNDATION. The foundation for your pump must be sufficiently rigid to absorb any vibration and stress encountered during pump operation. It must also be sufficient to withstand any pipe load transmitted through the volute. A raised foundation of concrete is preferable for most floor-mounted pumps. The raised foundation assures a satisfactory base, protects against flooding, simplifies moisture drainage, and facilitates keeping the area clean. Your pump should be firmly bolted to the foundation, whether it is a raised concrete base, steelwork wall, or structural member. The mounting bolts or lag screws should be accurately located per the applicable Aurora dimension sheet. Refer Fig. 1. LEVELING THE PUMP. Leveling the pump will require enough shims to support the base plate near the foundation bolts, and at any points of the base plate carrying a substantial weight load. The shims should be large enough to allow a gap of 3/4" to 1-1/2"' between the base plate and foundation for grouting. IMPORTANT: The pump base must be set level to avoid any mechanical difficulties with the pump or motor. The 3310 pump was properly aligned, if supplied with a motor, at the factory. However, since the pump base is flexible, it may spring and twist during shipment. Do not make any piping connection to the pump until it is realigned. Realign the pump after piping is completed and after the base is grouted in and bolted down. NOTE: It may be necessary to readjust the alignment from time to time while the unit and foundation are new. Realignment will prevent premature bearing failure, excessive vibration, or shaft failure. Ensure that proper hydronic accessories such as pressure relief valves, thermal expansion tanks, and flow/pressure control devices are installed in the system. Consult the responsible party for your system to ensure these devices are installed and of the proper size. GROUTING THE INSTALLATION. The area below the Figure 1. Foundation for Frame Mounted Pumps. SOUPY GROUT FOUNDATION BOLTS ROLLED STEEL BASE TWISTED TENSION WIRE SHIMS TO LEVEL BASEPLATE WOODEN DAM ON BOTH SIDES Figure 2. Grouting the Base for Frame Mounted Pumps. volute feet must be grouted prior to operation. Grouting the base plate prevents lateral movement of the base plate and improves the vibration absorbing characteristics of the foundation by increasing its mass. A wooden dam should be constructed around the base plate to contain the grout while it is being poured. The dam can be built tight against the base plate, or slightly removed from it as desired. Refer Fig. 2. The entire base plate should be completely filled with nonshrinkable type grout. The grout should be puddled frequently to remove any air bubbles from the grout. Warning: Sudden Start-Up Hazard Disconnect and lockout power source before servicing. Failure to follow these instructions could result in serious personal injury, death or property damage. STRAIGHT EDGE WEDGE OR THICKNESS GAUGE PARALLEL MISALIGNMENT 2 ANGULAR MISALIGNMENT Figure 3. Flexible Coupling Alignment. PERFECT ALIGNMENT MODEL 3310 ROTATION: Pump rotation is clockwise when viewed from the motor end. Discharge Piping Gate Valve INITIAL ALIGNMENT OF THE FLEXIBLE COUPLING. The pump and driver were accurately aligned at the factory. However, it is impossible to maintain this alignment during shipping and handling. Therefore it will be necessary for you to realign the pump and driver. Flexible couplings are not universal joints. They should not be used to compensate for misalignment of the pump and motor shafts. Their function is to transmit power from the driver to the pump while compensating for thermal expansion and shaft end movement. The coupling faces should be far enough apart so that they do not make contact when the motor shaft is forced to the limit of the bearing clearance toward the pump shaft. In order to properly align the coupling, you will need a taper gauge, or set of feeler gauges, and a straight edge. There are two types of misalignment encountered with flexible couplings: angular misalignment, in which the shafts are not parallel, and parallel misalignment where the shafts are parallel but not on the same axis. To check angular alignment, insert a feeler gauge or taper gage at any four places 90° apart around the coupling halves. Insert shims under the driver feet until the same reading is obtained at all four checkpoints. The pump and driver will then be in angular alignment. To check parallel alignment, a straight edge should be held against the edges of the coupling halves at any four places 90° apart around the coupling. The straight edge should be parallel to the pump and driver shafts at all times. Insert shims until the straight edge lies flat against both coupling halves at all four checkpoints. The pump and driver will then be in proper parallel alignment. Refer Fig. 3. For fine alignment, 3500 RPM operation, for all other coupler types. A dial indicator should be used when greater alignment accuracy is required. Use the following alignment tolerances unless specified otherwise by the coupling manufacturer. On sleeve type couplings make sure there is at least 1/8” end clearance between the sleeve and the two coupling halves. CORRECT ECCENTRIC TAPERED REDUCER POTENTIAL FOR AIR POCKET INCORRECT Figure 4. Installation of Tapered Reducers. Suction Piping Gate Valve Check Valve Figure 5. Gate Valve and Check Valve. To check angular misalignments, mount the dial indicator base to the coupling half and position the dial indicator button on the front or rear face of the opposite coupling half. Set the dial to zero, rotate both coupling halves together, making sure the indicator button always indicates off the same spot. Misalignment within 0.004 inches TIR per inch of coupler radius is permissible. To check parallel misalignment, mount the dial indicator base to one coupling half, or shaft, and position the dial indicator button on the outside diameter of the opposite coupling half. Set the dial to zero. Rotate both coupling halves together making sure the indicator button always indicates off the same spot. Misalignment within 0.004 inches TIR is permissible. PIPING: SUCTION PIPING. The suction piping should be short and direct with as few elbows and fittings as possible to keep head loss from friction to a minimum. A horizontal suction line should have a gradual rise to the pump, and pass under any interfering piping. The suction pipe diameter should be at least the same diameter as the suction nozzle on the pump, and preferably larger. Use of a smaller diameter pipe will result in loss of head due to friction. All joints must be tight to maintain prime on the pump. REDUCERS. For vertically mounted configuration installations, eccentric reducers should be installed directly at the suction nozzle with the taper at the bottom to prevent air pockets from forming. Straight taper reducers should never be used in a vertically mounted installation suction line because of the air pocket that is formed at the leg of the reducer and the pipe. Either eccentric or concentric reducers may be used for horizontally mounted installations. Refer Fig. 4. DISCHARGE PIPING. Discharge piping should also be short and direct as possible, with few elbows and fittings, to reduce head loss from friction. PIPE. The discharge pipe diameter should be the same as, or larger than, the discharge nozzle diameter. DISCHARGE VALVES. The discharge piping should include a check valve and a gate valve. The check valve should be located between the gate valve and the pump. If an increaser is used in the discharge piping, the increaser should be installed between the pump nozzle and the check valve. The check valve protects against a reverse flow of the liquid if the driver fails. Refer Fig. 5. 3 MODEL 3310 The gate valve is used in the priming operation, as a throttling valve to control pump volume, and to shut down the pump for inspection and maintenance. Warning: High Pressure Hazard In dry locations, each bearing will need lubrication at least after every 4,000 hours of running time or 6 to 12 months - whichever is more frequent. In wet locations (exposed to dripping water, to the weather or to heavy condensation found in unheated or poorly ventilated underground locations) every 2,000 hours or every 3 to 6 months - whichever is more frequent. Warning: Spraying Water Hazard LUBRICATION: Use Chevron SRI, NLGI2. Lubricate motor per motor manufacturer’s instructions. GENERAL INSTRUCTIONS: 1. Keep this pump and motor properly lubricated. 2. When there is a danger of freezing, drain the pump. 3. Inspect the pump regularly for leaky seals, gaskets and loose or damaged components. Replace or repair as required. ELECTRICAL WIRING. Normally, your pump will be supplied with an attached drive motor. The motor should be wired in accordance with the wiring diagram found on the motor nameplate. Be sure the voltage, frequency, and phase of your power supply corresponds with the nameplate data. It is advisable to provide a separate switch and overload protection for your pump motor to protect against power failure in some other area. Conversely, if the pump motor develops electrical problems, it will be isolated from other equipment. PRESTARTING INSTRUCTION. The coupling halves should be connected. Prior to connection, however, the drive motor should be started to make sure of proper pump rotation. Do not start pump until all air and vapor has been bled. This ensures that there is liquid in the pump to provide the necessary lubrication. Without the fluid around it, the seal may be ruined in a few seconds of operation. It is normal for the mechanical seal to drip during the first few minutes to one hour of operation. Warning: Sudden Start-Up Hazard Disconnect and lockout power source before servicing. Failure to follow these instructions could result in serious personal injury, death or property damage. PUMP DISASSEMBLY: For frame mounted pumps, model 3314. Read and understand all safety warnings at the beginning of the manual before beginning installation or any repair work. Warning: Hot Surface Hazard If pumping hot water, insure guards or proper insulation is installed to protect against skin contact with hot piping or pump components. Failure to follow these instructions could result in serious personal injury, death or property damage. 1. Ensure the electrical power is locked out, the system pressure has been lowered to 0 psi and temperature of the unit is at a safe level before beginning any disassembly of the pump. 4 The pump is rated at a maximum of 290 psi at 300°F. Do not exceed this pressure. Install properly sized pressure relief valves in system. Failure to follow these instructions could result in serious personal injury, death or property damage. When servicing pump replace all gaskets and seals. Do not re-use old gaskets or seals. Failure to follow these instructions could result in serious personal injury, death or property damage. 2. Isolate the pump from the system by closing the valves that should be located on both the suction and discharge of the pump. Loosen the drain plugs (4) at the bottom of the casing and drain the pump. Remove all relief, cooling, flushing, or drain lines from the pump. Inspect removed parts at disassembly to determine if they can be reused. Ball bearings that turn roughly or show wear should be replaced. Cracked castings should never be reused. Scored or worn pump shafts should be replaced. Gaskets should be replaced at reassembly simply as a matter of economy. They are much less expensive to replace routinely than to replace singly as the need arises. Warning: High Pressure Hazard Make certain that the internal pressure of the pump is relieved before continuing. Failure to follow the instructions could result in serious person injury, death, or property damage. 3. Remove the coupling guard. 4. Loosen the sets crews in both coupling halves and slide each half back, as far as possible on its shaft. Then, remove the coupling sleeve. 5. Loosen, but do not remove, the volute capscrews (5). Use capscrews in the jackscrew holes to loosen the pump rotating assembly from the volute (6). 6. Now remove the volute capscrews (5) and remove the power frame and rotating assembly from the volute (6). 7. Optional case wearing ring (7) is pressed into volute with an interference fit, and must be removed with a puller. New rings should be used for reassembly since it is likely that during removal this fit will be lost. 8. Remove the impeller capscrew (9), impeller washer (9A) and impeller washer gasket (9B), and bolt gasket (9C). Remove impeller (11). 9. Remove impeller key (12). 10. Remove the shaft sleeve (25), shaft sleeve gasket (10), and rotating portion of the mechanical seal (head). MODEL 3310 CAPSCREW TORQUE FOR COMMON BOLT DIAMETERS CAPSCREW TYPE SAE Grade 5 HEAD MARKING IN-POUNDS 1/4” 5/16” 85 180 UNITS DIN CLASS 8.8 (SAE Grade 5) KILOGRAM METERS FT-LBS 7/16” 43 M4 M6 M8 M10 M12 M14 M16 .57 1 2.5 5 8 13 20 7 18 32 58 94 144 4 Table 1. Torque Chart CAUTION 11. Remove the seal stationary seat and flexible cup. 12. Unscrew capscrews (32) and remove power frame (57) from the seal plate (35). 13. Thoroughly clean the shaft sleeve (25) and seal plate seal cavity. Replace the shaft sleeve (25) or seal plate (35) if there is evidence of surface damage like pitting, corrosion, nicks, or scratches. 14. Lubricate the shaft sleeve (25) and seal plate (35) with soap and water or P-80 rubber emulsion. Do not use petroleum lubricant. Install a new stationary seat and flexible cup down into the seal plate. Ensure that the stationary seat and flexible cup are fully inserted into the seal plate cavity. 15. Attach seal plate (35) to power frame (57) with capscrews (32). 16. Slide shaft sleeve (25) on to the short end and a new rotating seal assembly (27) on to the shaft sleeve (25) until the head is tight against the stationary seat. The mechanical seal (27) (see Figure 6) is a precision product and must be treated as such. During installation, great care must be taken to avoid dropping any part of the seal. Take particular care not to scratch the lapped faces on the head or stationary seat. 17. Install a new sleeve gasket (10). 18. Install a new impeller key (12). 19. Install impeller (11), impeller washer (9A), new impeller washer gasket (9B), bolt gasket (9C), and capscrew (9). Tighten capscrew per torque chart (see Table 1). 20. Press wearing ring (7) into volute (6) if equipped. Ring should not be hammered into place. Use a press, or clamp the parts into a bench vise, using wooden blocks to protect the ring. It may be necessary to pin or dowel the ring after assembly if the insert or volute has had rings replaced Warning: Sudden Start-Up Hazard 3/8” 27 FOOT-POUNDS 1/2” 5/8” 3/4” 65 130 230 Disconnect and lockout power source before servicing. Failure to follow these instructions could result in serious personal injury, death or property damage. before, since each reassembly can stretch or tear metal and thereby loosen the fit. If the facilities are available, it is good practice to take a very light finish cut or to ream the inside diameter of the ring after pressing to restore roundness. When rings are pressed, they may get squeezed out of shape. 21. Install new casing gasket (8). Then install the rotating assembly into the volute (6). 22. Tighten volute capscrews (5) per torque chart (see Table 1). 23. Install and align coupling. 24. Install drain plugs (4). 25. Reinstall the coupling guard. 26. Open isolation valves and inspect pump for leaks. 27. Return pump to service. PUMP DISASSEMBLY FOR CLOSED COUPLED PUMPS, MODELS 3311 & 3312: Read and understand all safety warnings at the beginning of the manual before beginning installation or any repair work. 1. Ensure the electrical power is locked out, the system pressure has been lowered to 0 psi and temperature of the unit is at a safe level before beginning any disassembly of the pump. 2. Isolate the pump from the system by closing the valves that should be located on both the suction and discharge of the pump. Loosen the drain plug (4) at the bottom of the casing and drain the pump. Remove all relief, cooling, flushing, or drain lines from the pump. Warning: Hot Surface Hazard If pumping hot water, insure guards or proper insulation is installed to protect against skin contact to hot piping or pump components. Failure to follow these instructions could result in serious personal injury, death or property damage. Warning: High Pressure Hazard Make certain that the internal pressure of the pump is relieved before continuing. Failure to follow the instructions could result in serious person injury, death, or property damage. 5 MODEL 3310 Inspect removed parts at disassembly to determine if they can be reused. Ball bearings that turn roughly or show wear should be replaced. Cracked volutes (6) should never be used. Scored or worn pump shafts should be replaced. Gaskets should be replaced at reassembly simply as a matter of economy. They are much less expensive to replace routinely than to replace singly as the need arises. 3. Remove motor foot capscrews. Loosen the volute capscrews (5), but do not remove them. Using the capscrews in the jackscrew holes, start to remove the rotating assembly from the volute (6). 4. Remove the volute capscrews (5) and remove the rotating assembly. 5. Remove the impeller capscrew (9), impeller washer (9A), impeller washer gasket (9B), and bolt gasket (9C). 6. Remove the impeller (11). 7. Remove impeller key (12). 8. Remove the shaft sleeve (25), shaft sleeve gasket (10), and rotating portion of the mechanical seal (head). 9. Remove the seal stationary seat and flexible cup. 10. Unscrew capscrews (48) and remove bracket (36) from the motor. 11. Thoroughly clean the shaft sleeve (25) and the seal plate or motor bracket, seal cavity. Replace the shaft sleeve, seal plate (35), or motor if there is evidence of surface damage like pitting, corrosion, nicks or scratches. Head 6 12. Lubricate the shaft sleeve (25) and seal plate (36) of motor bracket with with soap and water or P-80 rubber emulsion. Do not use petroleum lubricant. Install a new stationary seat and flexible cup down into the seal plate or the motor bracket. Ensure that the stationary seat and flexible cup are fully inserted into the seal plate cavity or motor bracket. 13. Slide a new rotating seal assembly (27) onto the shaft sleeve (25) until the head is tight against the stationary seat. The mechanical seal (27) (see Figure 6) is a precision product and must be treated as such. During installation, great care must be taken to avoid dropping any part of the seal. Take particular care not to scratch the lapped faces on the head or stationary seat. 14. Install a new sleeve gasket (10). 15. Install new impeller key (12). 16. Install impeller (11) new impeller washer gasket (9B), impeller washer (9A), bolt gasket (9C), and capscrew (9). 17. Install a new casing gasket (8). Then install the rotating assembly into volute (6). 18. Tighten volute capscrews (5) per torque chart (see Table 1). 19. Install drain plug (4). 20. Open isolation valves and inspect pump for leaks. 21. Return pump to service. Stationary Seat Figure 6. Mechanical Seal. Flexible Cup MODEL 3311/33112 LIST OF PARTS 4. 5. 6. 7. 8. 9. 9A. 9B. 9C. 10. 11. 12. 25. 27. 32. 35. 36. 48. Pipe Plug Bolts Casing Casing Wear Ring Gasket Capscrew Impeller Washer Impeller Gasket Bolt Gasket Sleeve Gasket Impeller Key Sleeve Mechanical Seal Bolts Seal Plate Motor Bracket Bolts MODEL 3314 LIST OF PARTS 4. 5. 6. 7. 8. 9. 9A. 9B. 9C. 10. 11. 12. 25. 27. 32. 35. 48. 57. Pipe Plug Bolts Casing Casing Wear Ring Gasket Capscrew Impeller Washer Impeller Gasket Bolt Gasket Sleeve Gakset Impeller Key Sleeve Mechanical Seal Bolts Seal Plate Bolts Power Frame NOTES: 1. BRONZE FITTED CONSTRUCTION WILL BE FURNISHED 2. AURORA PUMP RESERVES THE RIGHT TO SUBSTITUTE MATERIALS WITHOUT NOTICE NOTE WHEN ORDERING SPARE PARTS ALWAYS INCLUDE THE PUMP TYPE, SIZE, SERIAL NUMBER, THE PIECE NUMBER FROM THE EXPLODED VIEW IN THIS MANUAL AND THE PART NUMBER. ORDER ALL PARTS FROM YOUR LOCAL AUTHORIZED DISTRIBUTOR, OR THE FACTORY AT NORTH AURORA, ILLINOIS. 7 MODEL 3311/3312 NOTE: Recommended spare parts shown in bold face type. 8 Figure 7. Model 3311/3312 Exploded View. MODELS 3314 NOTE: Recommended spare parts shown in bold face type. Figure 8. Model 3314 Exploded View. 9 NOTES 10 NOTES 11 AP-Sect. 6 - Item 3310 07.05 NOTE: Aurora Pump reserves the right to make revisions to its products and their specifications, this bulletin and related information without notice 12 Aurora Pump 800 Airport Road North Aurora, IL 60542 phone: 630-859-7000 fax: 630-859-7060
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement