E-IOM-W1104

E-IOM-W1104
Y8USE - 09, 12, 18, 24 - 5R
by johnson controls
Ref: E-IOM-W1104
GB
Window unit
Installation, Operating and Maintenance Instructions
Johnson Controls Manufacturing España, S.L. is participating in the EUROVENT Certification Programme.
Products are as listed in the EUROVENT Directory of Certified Products, in the program AC1, AC2,
AC3, LCP and FC.
The LCP program covers air condensed water chillers and heat pumps of up to 600 kW
by johnson controls
Physical data
Model
Y8USE09-5R
Y8USE12-5R
Y8USE18-5R
Y8USE24-5R
Cooling capacity
kW
2.7
3.7
5.3
6.0
Heating capacity
kW
2.4
3.2
4.8
5.5
Rated Voltage / Frequency
230V / 50Hz
Power Input (cooling/healing)
W
900 / 800
1230 / 1060
1760 / 1590
1990 / 1830
Rated Input (cooling/healing)
W
1160 / 1000
1800 / 1550
2300 / 2200
2500 / 2700
Rated Current (cooling/healing)
A
5.04 / 4.34
9.1 / 7.8
11.1 / 10.6
12.1 / 13
m3/h
500
730
850
900
l/h
0.8
1.6
2.2
2.2
3.0 / 3.0
3.0 / 3.0
3.01 / 3.01
3.01 / 3.01
Ø 205.5 X 111
Ø 201.5 X 109.5
Air Flow Volume
Dehumidifying Volume
EER / C.O.P
Fan Type-Piece
Diameter-Length
Cross flow fan – 1
mm
Evaporator
Pipe Diameter
mm
Row-Fin Gap
Indoor Side
Coil length x height x width
mm
Swing Motor Model
Ø 201.5 X 109.5
Ø7
Ø7
Ø7
Ø7
3-1.3
2-1.3
4-1.6
4-1.6
330 x 323.9 x 38.1
392 x 381 x 25.4
422 x 381 x 50.8
422 x 381 x 50.8
MP24VA
SM020B
MP28ED
MP28ED
Output of Swing Motor
W
2.5
4
4
4
Fuse
A
/
0.02
0.02
0.02
Sound Pressure Level (H/M/L)
dB(A)
49 / 47 / 45
50 / 48 / 46
57 / 55 / 53
58 / 56 / 53
Sound Power Level (H/M/L)
dB(A)
59 / 57 / 55
60 / 58 / 56
67 / 65 / 63
68 / 66 / 63
MATSUSHITAWANBAO
(GUANGZHOU)
COMPRESSOR CO.,LTD
CHINA RESOURCES
(SHENYANG) SANYO
COMPRESSOR CO., LTD.
Shanghai Hitachi
Electrical
Appliances Co., Ltd
Shanghai Hitachi
Electrical
Appliances Co., Ltd
5PS102EAA22
C-ARV146H1AA
ASH201SV-C8LU
ASH232SV-C8LU
8.8
Compressor Manufacturer
Compressor Model
Compressor Type
Rotary
L.R.A.
A
3.85
5.2
7.7
Compressor RLA
A
20.9
28
40
40
Compressor Power Input
W
850
1195
1660
1900
Overload Protector
Outdoor
Side
Ø 201.5 X 109.5
Aluminum fin-copper tube
outerior overload protection
Throttling Method
Capillary
Starting Method
Capacitor
Working Temp Range
ºC
-7~45
Condenser
Aluminum fin-copper tube
Pipe Diameter
mm
Ø7
Ø7
Ø7
Ø7
Rows-Fin Gap
mm
3-1.4
2-1.3
3-1.4
3-1.4
Coil length x height x width
mm
472 x 358 x 38.1
713 x 400 x 25.4
885 x 400.8 x 38.1
885 x 400.8 x 38.1
Axial fan –1
Axial fan –1
Axial fan –1
Axial fan –1
Fan Type-Piece
Fan Diameter
mm
Ø 353
Ø 396
Ø 396
Ø 396
Sound Pressure Level (H/M/L)
dB(A)
56 / 54 / 52
58 / 56 / 54
61 / 59 / 57
64 / 62 / 59
Sound Power Level (H/M/L)
dB(A)
66 / 64 / 62
68 / 66 / 64
71 / 69 / 67
74 / 72 / 69
/
/
/
/
920 / 820 / 720
840 / 780 / 730
1030 / 930 / 830
1140 / 1040 / 940
Defrosting Method
Fan Motor Speed (H/M/L)
rpm
Output of Fan Motor
W
88
100
190
200
Fan Motor RLA
A
0.4
0.45
0.8
0.8
Fan Motor Capacitor
uF
5
6
6
6
T1
T1
T1
T1
Climate Type
Isolation
Moisture Protection
I
I
I
I
IP24
IP24
IP24
IP24
Permissible Excessive Operating Pressure for
the Discharge Side
MPa
3
3
3
2.7
Permissible Excessive Operating Pressure for
the Suction Side
MPa
1
1
1
0.6
Dimension (W / H / D)
mm
618 / 560 / 375
660 / 700 / 428
660 / 700 / 428
660 / 700 / 428
Dimension of Package (L / W / H)
mm
687 / 621 / 435
736 / 790 / 500
736 / 790 / 500
736 / 790 / 500
Net Weight /Gross Weight
kg
43 / 47
54 / 58
66 / 73
75 / 82
Refrigerant Charge
kg
R410A: 0.78
R410A: 0.81
R410A: 1.27
R410A: 1.4
3
by johnson controls
Part name
Cabinet
Air inlet louver
Front grille
Front intake grille)
Air filter
(behind the front intake grille)
4
Remote control panel
Power cord
by johnson controls
Outline and installation dimension
D
W
H
Y8USE09-5R
Y8USE12-5R
Y8USE18-5R
Y8USE24-5R
W
560
660
660
660
H
375
428
428
428
D
618
700
770
770
Model
5
by johnson controls
Wiring diagrams
Y8USE09-5R
Y8USE12-5R
6
by johnson controls
Wiring diagrams
Y8USE18-5R
Y8USE24-5R
7
by johnson controls
Operation of wireless remote control
8
by johnson controls
Operation of wireless remote control
9
by johnson controls
Operation of wireless remote control
10
by johnson controls
Operation of wireless remote control
11
by johnson controls
Operation of wireless remote control
12
by johnson controls
13
by johnson controls
14
DECLARACION CE DE CONFORMIDAD SOBRE MAQUINAS
FABRICANTE:
JOHNSON CONTROLS MANUFACTURING ESPAÑA, S.L.
DIRECCIÓN:
Paseo Espronceda, 278, 08204 SABADELL
Certificamos que el equipo descrito, ha sido diseñado, fabricado y probado de conformidad con los requisitos básicos de la Directiva de Equipos a
presión 97/23/CEE y sus correspondientes módulos de aplicación. Así mismo certificamos que el equipo es conforme a las exigencias básicas de las
Directivas Europeas que le son aplicables, incluidas las modificaciones de las mismas y las correspondientes transposiciones a la ley nacional.
APLICACIÓN DE LA MÁQUINA:
TIPO:
AIRE ACONDICIONADO/REFRIGERACION
Y8USE 09, 12, 18, 24 - 5R
DIRECTIVAS DE LA CE APLICADAS:
2006/95/CEE, 2004/108/CEE, 97/23/CEE
NORMAS ARMONIZADAS APLICADAS:
EN6335-1, EN6335-2-40, EN62233, EN61000-6-3,
EN61000-6-1, EN61800-3
NORMAS INTERNACIONALES Y
ESPECIFICACIONES TÉCNICAS APLICADAS:
LUGAR:
EN ISO 9001, EN ISO 14001
Sabadell, (España)
FIRMA:
DAVID MURRAY
USG LOGISTICS MANAGER
DECLARATION OF COMPLIANCE ON MACHINERY
MANUFACTURER:
JOHNSON CONTROLS MANUFACTURING ESPAÑA, S.L.
ADDRESS:
Paseo Espronceda, 278, 08.204 SABADELL
We hereby certify that the mentioned equipment has been designed, manufactured and tested in accordance with essential requirements of Pressure
Equipment Directive 97/23/EEC and its relevant application modules. We futher certify that the equipment complies with the essential requirements
of the European Directives applicable, including their modifications and the corresponding transpositions from the national law.
APPLICATION OF THE MACHINE:
TYPE:
AIR CONDITIONER/COOLING
Y8USE 09, 12, 18, 24 - 5R
EC STANDARDS APPLIED:
2006/95/CEE, 2004/108/CEE, 97/23/CEE
MATCHING STANDARDS APPLIED:
EN6335-1, EN6335-2-40, EN62233, EN61000-6-3,
EN61000-6-1, EN61800-3
INTERNATIONAL STANDARDS AND TECHNICAL SPECIFICATIONS
APPLIED :
PLACE:
Sabadell, (España)
EN ISO 9001, EN ISO 14001
SIGNATURES:
DAVID MURRAY
USG LOGISTICS MANAGER
27
www.johnsoncontrols.com