LiftMaster LA400 gate operator OWNER’S MANUAL 32 Pages

The LA400 is a medium-duty swing gate operator that is designed for use with vehicular swing gates. It can be used in residential, commercial, and industrial applications. The operator is powered by 24Vdc and has a maximum gate width of 16 ft (4.9 m) and a maximum gate weight of 550 lbs (249.5 kg). The operator can operate a gate for up to 4 minutes and has a travel time of 14-18 seconds for a 90 degree opening.

advertisement

LiftMaster LA400 Medium Duty Swing Gate Operator Owner's Manual | Manualzz
OWNER’S
MANUAL
MODEL LA400
MEDIUM DUTY SWING GATE OPERATOR
2 YEAR WARRANTY
Serial # Primary Arm
Serial # Secondary Arm
Serial # Box
Installation Date
TABLE OF CONTENTS
TABLE OF CONTENTS
OPERATOR SPECIFICATIONS
WARNING
Tools Needed for Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Carton Inventory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Additional Items Needed for Installation . . . . . . . . . . . . . . . . . . .3
Operator Dimensions and Specifications . . . . . . . . . . . . . . . . . . .3
UL325 Classifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Mechanical
CAUTION
WARNING
WARNING
Electrical
WARNING
CAUTION
WARNING
OPERATOR
WARNINGS
CAUTION
Safety Installation Information . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Suggested Entrapment Protection Device Locations . . . . . . . . . .6
Warnings and Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Warning Sign Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
When you see these Safety Symbols and Signal Words on the
following pages, they will alert you to the possibility of serious
injury or death if you do not comply with the warnings that
accompany them. The hazard may come from something
mechanical or from electric shock. Read the warnings carefully.
When you see this Signal Word on the following pages, it will
alert you to the possibility of damage to your gate and/or the gate
operator if you do not comply with the cautionary statements that
accompany it. Read them carefully.
INSTALLATION
Gate Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Pull-to-Open Bracket Mounting Instructions . . . . . . . . . . . . . . . .9
Push-to-Open Bracket Mounting Instructions
(for use with Accessory Kit 50-19503) . . . . . . . . . . . . . . . . .10-11
Control Box Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Control Box Mounting with U-Bolts . . . . . . . . . . . . . . . . . . . . . .12
WIRING
IMPORTANT NOTE
Connect Arm to Control Box . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Earth Ground Rod Installation . . . . . . . . . . . . . . . . . . . . . . . . . .13
Control Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
• BEFORE attempting to install, operate or maintain the operator,
you must read and fully understand this manual and follow all
safety instructions.
• DO NOT attempt repair or service of your commercial door and
gate operator unless you are an Authorized Service Technician.
BASIC CONTROL BOARD SETUP
Set Dip Switch for Gate Type . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Programming Remote . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Wire Stop Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Optional Control Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . .18-20
Force and Timer to Close . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Program Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
DIP Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
TOOLS NEEDED FOR INSTALLATION
During assembly, installation and adjustment of the operator the
tools listed below will be needed.
• Wrench or Socket Set
• Phillips Head Screwdriver
• C Clamps
• Level
• Small Screwdriver
• T25 Torx Head Screwdriver
OPERATION AND MAINTENANCE
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Battery Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Manual Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . .27-28
REPAIR PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29-30
WARRANTY POLICY AND SERVICE . . . . . . . . . . . . . . . .32
2
CARTON INVENTORY
HARDWARE KIT LA400 (K77-19130)
DESCRIPTION
Post Bracket
Pull to Open Bracket
Hex Bolt 5/16"-18 X 1-1/2"
Square Neck Carriage Bolt 3/8"-16 X 6"
Hex Nut 3/8"-16
Hex Nut 5/16"-18
Flat Washer 5/16"
Flat Washer 3/8"
Lock Washer 5/16"
Lock Washer 3/8"
Gate Mounting Bracket
Hairpin Clip
Pin
Hex Bolt 3/8"-16 X 1-1/2"
Bolt 2-3/4"
CONTROL BOX LA400 (LA-CONTROL)
QTY
1
1
5
2
5
5
5
5
5
5
1
4
2
1
2
DESCRIPTION
Control Box
Hardware Bag
QTY
1
1
MISCELLANEOUS
Linear Actuator Arm - Model LA400-1K (1) or 2 (LA400-2K)
Warning Sign
2
Battery
2
Plug-In Transformer
1
LA400-S
Extension Cable - Six Conductor
Junction Box - IP56
Phillips Head Mounting Screws
Anchors
Terminal Block - Twelve Connectors
40' (12.2 m)
1
4
4
1
NOTE: Carton inventory is based on a Single Operator. For Primary (Gate 1) and Secondary (Gate 2) installation the carton
inventory is doubled except for control box (1).
A D D I T I O N A L I T E M S N E E D E D F O R I N S TA L L AT I O N
Permanent fasteners for warning sign
Earth Ground Rod (Optional)
Power Wire: 120Vac (Stranded Copper Wire)
Power Wire: 24Vac Transformer (Stranded Copper Wire)
Wire Gauge
Length
Wire Gauge
Length
OR
16
100' (30 m)
14
500' (152 m)
10
1000' (305 m)
12
1000' (305 m)
O P E R AT O R D I M E N S I O N S A N D S P E C I F I C AT I O N S
Main Supply (Motor)
24Vdc
Current Consumption
2A
Power Consumption
48 Watts
Battery Charger Supply
26Vac, 29VA or 36Vdc, 40VA
Solar Panel Supply (Optional)
27.4V, 9W (Minimum)
Maximum Gate Width
16 ft. (4.9 m)
Maximum Gate Weight
550 Lbs. (249.5 kg)
Protection Class
NEMA 3R
Travel Speed
14-18 seconds for a 90 degree opening
Rated Operating Time
4 Minutes
Temperature
-20˚C to + 50˚C
-4˚F to + 122˚F
Main Supply (Control) Dedicated Circuit
120V~/60Hz
Absorbed Power
0.75 Watts
Protection Fuse Gate 1
ATC 15A
Protection Fuse Gate 2
ATC 15A
Protection Fuse Battery
ATC 20A
Weight: 47Lbs. (21 kg.)
32.10"
(81.5 cm)
4.00"
(10.2 cm)
.475" DIA.
(1.2 cm DIA.)
33.25"
(84.5 cm)
.250"
4.50"
(0.635 cm)
(11.2 cm)
3
U L 3 2 5 M O D E L C L A S S I F I C AT I O N S
The LA400 is intended for use with vehicular swing gates. The opener can be used in Class I, Class II and Class III applications.
CLASS I – RESIDENTIAL VEHICULAR GATE OPERATOR
A vehicular gate operator (or system) intended for use in a home of one-to four single family dwelling, or
a garage or parking area associated therewith.
CLASS II – COMMERCIAL/GENERAL ACCESS VEHICULAR GATE OPERATOR
A vehicular gate operator (or system) intended for use in a commercial location or building such as a
multi-family housing unit (five or more single family units) hotel, garages, retail store or other building
servicing the general public.
CLASS III – INDUSTRIAL/LIMITED ACCESS VEHICULAR GATE OPERATOR
A vehicular gate operator (or system) intended for use in a industrial location or building such as a
factory or loading dock area or other locations not intended to service the general public.
UL325 ENTRAPMENT PROTECTION
REQUIREMENTS
SAFETY ACCESSORY SELECTION
All UL325 compliant LiftMaster gate operators will accept external
entrapment protection devices to protect people from motorized
gate systems. UL325 requires that the type of entrapment
protection correctly matches each gate application. Below are the
four types of entrapment protection systems recognized by
UL325 for use on this operator.
Gate Operator Entrapment Protection
UL325
Swing and Gate Barrier
Installation
(Arm) Operator
ENTRAPMENT PROTECTION TYPES
Type A: Inherent obstruction sensing system, self-contained
within the operator. This system must sense and initiate
the reverse of the gate within two seconds of contact
with a solid object.
Type B1: Connections provided for a non-contact device, such as
a photoelectric eye can be used as a secondary
protection.
Type B2: Connections provided for a contact sensor. A contact
device such as a gate edge can be used for secondary
protection.
Type E: Built-in audio alarm. Examples include sirens, horns
or buzzers.
NOTE: UL requires that all installations must
have warning signs placed in plain view on
both sides of the gate to warn pedestrians of
the dangers of motorized gate systems.
Primary
Type
Secondary
Type
Class
I and II
A
A, B1 or
B2
Class III
A, B1 or B2
A, B1,
B2 or E
Class
The chart above illustrates the entrapment protection
requirements for each of the three UL325 classes.
In order to complete a proper installation you must satisfy the
entrapment protection chart shown above. That means that
the installation must have one primary means of entrapment
protection and one independent secondary means of
entrapment protection. Both primary and secondary
entrapment protection methods must be designed, arranged
or configured to protect against entrapments in both the open
and close directions of gate travel.
For Example: For a slide gate system that is installed on a
single-family residence (UL325 Class I) you must provide the
following: As your primary type of entrapment protection you
must provide Type A inherent (built into the operator)
entrapment sensing and at least one of the following as your
secondary entrapment protection: Type B1- Non-contact
sensors such as photoelectric eyes, Type B2- Contact sensors
such as gate edges.
Moving Gate Can Cause
Injury or Death
KEEP CLEAR! Gate may move at any
time without prior warning.
Do not let children operate the gate or
play in the gate area.
This entrance is for vehicles only
Pedestrians must use separate entrance
4
S A F ET Y I N S TA L L AT I O N I N F O R M AT I O N
1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only
one component. Each gate system is specifically designed for an individual application.
2. Gate operating system designers, installers and users must take into account the possible hazards associated with each individual application.
Improperly designed, installed or maintained systems can create risks for the user as well as the bystander. Gate systems design and
installation must reduce public exposure to potential hazards.
3. A gate operator can create high levels of force in its function as a component part of a gate system. Therefore, safety features must be
incorporated into every design. Specific safety features include:
• Gate Edges
• Guards for Exposed Rollers
• Photoelectric Sensors
• Screen Mesh
• Vertical Posts
• Instructional and Precautionary Signage
4. Install the gate operator only when:
a. The operator is appropriate for the construction and the usage class of the gate.
b. All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4' (1.2 m) above the ground to
prevent a 2-1/4" (6 cm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence
that the gate covers in the open position.
c. All exposed pinch points are eliminated or guarded, and guarding is supplied for exposed rollers.
5. The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. The
pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that persons will not come in contact with the
vehicular gate during the entire path of travel of the vehicular gate.
6. The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and
closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas.
7. The gate must be properly installed and work freely in both directions prior to the installation of the gate operator.
8. Controls intended for user activation must be located at least six feet (6') away from any moving part of the gate and where the user is
prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or easily accessible controls shall have a
security feature to prevent unauthorized use.
9. The Stop and/or Reset (if provided separately) must be located in the line-of-sight of the gate. Activation of the reset control shall not cause the
operator to start.
10. A minimum of two (2) WARNING SIGNS shall be installed, one on each side of the gate where easily visible.
11. For a gate operator utilizing a non-contact sensor:
a. Reference owner’s manual regarding placement of non-contact sensor for each type of application.
b. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still moving.
c. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a
moving gate or barrier.
12. For a gate operator utilizing a contact sensor such as an edge sensor:
a. One or more contact sensors shall be located where the risk of entrapment or obstruction exists, such as at the leading edge, trailing edge
and post mounted both inside and outside of a vehicular horizontal slide gate.
b. One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate.
c. A hard wired contact sensor shall be located and its wiring arranged so the communication between the sensor and the gate operator is not
subject to mechanical damage.
d. A wireless contact sensor such as the one that transmits radio frequency (RF) signals to the gate operator for entrapment protection
functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or
similar obstruction. A wireless contact sensor shall function under the intended end-use conditions.
e. One or more contact sensors shall be located on the inside and outside leading edge of a swing gate. Additionally, if the bottom edge of a
swing gate is greater than 6" (152 mm) above the ground at any point in its arc of travel, one or more contact sensors shall be located on
the bottom edge.
f. One or more contact sensors shall be located at the bottom edge of a vertical barrier (arm).
5
S U G G E S T E D E N T R A P M E N T P R O T E C T I O N D E V I C E LO C AT I O N S
SWING GATE SYSTEM
Telephone
Entry System
STREET
t
up
err
Int Loop
Photo Eye for
Open Cycle
m)
1.2ical
(
'
4 yp
T
ow
ad
Sh Loop
Seal Loops
1-1/2"
(37 mm)
Loop Wire Layer
1/4" (6 mm) or larger
depending on Loop
Wire size
t
up
err
Int Loop
Shadow loop should be positioned in direction
of gate travel. Pull-to-open illustrated.
The shadow loop input is only active when the
gate is in the fully open or fully closed positions.
4
Typ' (1.2
ica m)
l
Photo Eye for
Close Cycle
Run Twisted Wire
from Loop to Operator
COMPLEX
OR
PARKING LOT
DUAL SWING GATE SYSTEM
Telephone
Entry System
Gate 2
Junction
Box
STREET
Extension Cable
t
up
err
Int Loop
Photo Eye for
Open Cycle
m)
1.2 al
4' ( ypic
T
Seal Loops
1-1/2"
(37 mm)
ow
ad
Sh oop
L
Control
Box
t
up
err
Int Loop
Gate 1
Shadow loop should be positioned in direction
of gate travel. Pull-to-open illustrated.
The shadow loop input is only active when the
gate is in the fully open or fully closed positions.
Run Twisted Wire
from Loop to Operator
4
Typ' (1.2
ica m)
l
Photo Eye for
Close Cycle
6
Loop Wire Layer
1/4" (6 mm) or larger
depending on Loop
Wire size
COMPLEX
OR
PARKING LOT
SAFETY PRECAUTIONS FOR SWING AND
ORNAMENTAL "GRILL TYPE GATES"
WARNING
WARNING
To prevent SERIOUS INJURY or DEATH from a moving gate:
• Entrapment protection devices MUST be installed to protect
anyone who may come near a moving gate.
• Locate entrapment protection devices to protect in BOTH the
open and close gate cycles.
• Locate entrapment protection devices to protect between
moving gate and RIGID objects, such as posts.
• A swinging gate shall NOT open into public access ways.
CAUTION
WARNING
WARNING SIGN PLACEMENT
WARNING
WARNING
To prevent SERIOUS INJURY or DEATH from a moving gate:
• Install warning signs on EACH side of gate in PLAIN VIEW.
• Permanently secure each warning sign in a suitable manner
using fastening holes.
CAUTION
WARNING
Moving Gate Can Cause
Injury or Death
KEEP CLEAR! Gate may move at any
time without prior warning.
Do not let children operate the gate or
play in the gate area.
This entrance is for vehicles only
Pedestrians must use separate entrance
7
I N S TA L L AT I O N
SINGLE GATE SETUP
Post Bracket Assembly
Gate Operator
Antenna
Warning Sign
Control Box
with Batteries
4-1/2' (1.4 m)
Power Cable
Earth Ground
Installation
(Optional,
See Page 13)
Gate Bracket
12 gauge wire
PVC conduit (not included)
to protect the power cable
and low voltage wire from
lawn mowers and string trimmer.
8 ft.
(2.4 m)
DUAL GATE SETUP
Post Bracket Assembly
Antenna
Gate Operator 2
Gate Operator 1
Junction Box
Control Box
with Batteries
Earth Ground
Installation
(Optional,
See Page 13)
12 gauge wire
4-1/2' (1.4 m)
Power Cable
Gate Bracket
PVC conduit (not included) to protect the power cable
and low voltage wire from lawn mowers and string trimmer.
Extension Cable
8 ft.
(2.4 m)
8
PULL-TO-OPEN BRACKET MOUNTING INSTRUCTIONS
NOTE: The mounting illustrations represent a typical installation using the provided gate hardware. The gate opener may also be
installed by welding it to the gate structure. For push-to-open installation order accessory kit 50-19503.
1. Place pull-to-open bracket on top of the post bracket. Insert
3/8" hex bolt through middle hole and secure with lock
washer, flat washer and nut. Insert 5/16" hex bolt through
hole in pull-to-open bracket and post bracket. Secure with
washer, lock washer and nut (Figure 1).
NOTE: Do not pivot bracket, bracket must be straight or you may
damage your gate, operator or gate post bracket.
2. Determine the vertical position of the gate post bracket
assembly on the gate post by aligning the gate post bracket
with one of the cross members of the gate. For optimal
performance, align the gate post bracket to a cross member
that is as close to the vertical center of the gate post as
possible. Level gate post bracket assembly and temporarily
secure to gate post using C clamp (Figure 2).
3. Move the gate post bracket assembly to obtain desired
dimensions. Ideally, the distance between and opener hinge
points should be approximately 7" (18 cm) x 7" (18 cm).
Place opener against gate post and adjust the opener until
the required dimension is achieved (Figure 3).
Figure 3
Gate Post
Figure 1
5/16" Hex Bolt
Pull-to-Open
Bracket
3/8" Washer
3/8" Lock Washer
3/8" Nut
Gate Post
Gate Hinge Point
Gate Hinge Point
7" (18 cm)
7" (18 cm)
7" (18 cm)
Opener Hinge
Point
7" (18 cm)
7" (18 cm)
Gate Post
Gate Post
Gate Hinge Point
C Clamp
Fence
Post
Opener Hinge
Point
Gate Post
Horizontal
Center of Gate
Cross Member
Post Bracket
7" (18 cm)
Opener Hinge
Point
Post Bracket
Assembly
3/8" Hex Bolt
Gate Post
Gate Hinge Point
Figure 2
Gate Hinge Point
Gate Hinge Point
7" (18 cm)
7" (18 cm)
Opener Hinge
Point
7" (18 cm)
7" (18 cm)
Opener Hinge
Point
Opener Hinge
Point
7" (18 cm)
7" (18 cm)
4. Attach operator to gate post bracket by inserting pull-to-open
bracket into slot on the motor side of operator. Temporarily
secure with pin (Figure 4).
Figure 4
Post Bracket
Pin
Hairpin Clip
Gate Post
9
Gate In
OPEN Position
5. Fasten gate bracket to the actuator side of the operator using
pin. Swing operator to the desired open position (Figure 5).
6. Open gate to full open position (Do not exceed 100°). Adjust
operator until it is level and position bracket against the cross
member. Secure using C clamp (Figure 6).
7. Remove pins and detach operator.
8. Mark holes for post bracket assembly and gate bracket. Be
sure to mark holes in the vertical center of post bracket slots.
NOTE: All four gate bracket mounting holes must be used.
9. Remove brackets from gate post and cross member.
10. Drill 13/32" holes in marked locations for gate posts and
11/32" for gate bracket.
11. Secure gate posts bracket assembly to gate post using 3/8"
bolts, lock washer, flat washer and nuts. Secure gate bracket
to cross member using 5/16" bolts, lock washer, flat washer
and nuts.
12. Reattach operator to gate using pins and hairpin clips.
NOTE: After final limit adjustments (page 21) the gate can be
opened slightly further by increasing the distance between center
of gate hinge and the gate bracket by 1" (25.4 mm). Do not move
the post bracket assembly.
Figure 5
Actuator Side
Pin
Gate Bracket
Hairpin Clip
Figure 6
Operator MUST be level
Gate In OPEN Position
Gate Bracket
C Clamp
PUSH-TO-OPEN BRACKET MOUNTING
INSTRUCTIONS (FOR USE WITH ACCESSORY KIT
50-19503)
Figure 1
1. Place push-to-open bracket between the two post brackets.
Insert 3/8" hex bolt through middle hole and secure with lock
washer, flat washer and nut (Figure 1).
2. Determine the vertical position of the gate post bracket
assembly on the gate post by aligning the gate post bracket
with one of the cross members of the gate (Figure 2). For
optimal performance, align the gate post bracket to a cross
member that is as close to the vertical center of the gate post
as possible. Level gate post bracket, mark holes and
temporarily secure to gate post using C clamp (Figure 2).
3. Rotate the push-to-open bracket to obtain desired dimensions
(Figure 3).
3/8" Hex Bolt
Post Bracket
Push-to-Open Bracket
Post Bracket
3/8" Flat Washer
3/8" Lock Washer
3/8" Nut
Figure 2
Figure 3
Center of Gate Hinge
Post Bracket
Assembly
Horizontal
Center of Gate
Cross Member
Horizontal Center of
Gate Cross Member
Gate In
CLOSED Position
5/16" Hex Bolt
7-3/4"
(19.7 cm)
90˚
C Clamp
7-3/4"
(19.7 cm)
Fence
Post
Special Post Pivot Bracket for
Push-to-Open Installation
10
4. Attach operator to gate post bracket by inserting
push-to-open bracket into slot on the motor side of operator.
Secure with pin (Figure 4).
5. Fasten gate bracket to the actuator side of the operator using
pin. Swing operator to the desired closed position (Figure 4).
6. Position gate to full closed position. Adjust operator until it is
level and position bracket against the cross member. Secure
using C clamp (Figure 5).
Figure 4
Pin
Hex Bolt
Post Bracket
Push-to-Open Bracket
Flat Washer
Lock Washer
Pin
Nut
Hairpin Clip
Gate Bracket
7. Remove pins and detach operator.
8. Mark holes for post bracket assembly and gate bracket. Be
sure to mark holes in the vertical center of post bracket slots.
NOTE: All four mounting holes must be used.
9. Remove brackets from gate post and cross member.
10. Drill 13/32" holes in marked locations for gate posts and
11/32" for gate bracket.
11. Secure gate posts bracket assembly to gate post using 3/8"
bolts, lock washer, flat washer and nuts. Secure gate bracket
to cross member using 5/16" bolts, lock washer, flat washer
and nuts (Figures 6 & 7).
12. Reattach operator to gate using pins and hairpin clips.
NOTE: After final limit adjustments (page 21) the gate can be
closed slightly further by increasing the distance between center
of gate hinge and the gate bracket by 1" (25.4 mm). Do not move
the post bracket assembly.
Hairpin Clip
Figure 6
Gate In Open Position
Mark cross member through middle of
gate bracket slots and drill 11/32" holes
Figure 7
Mark fence post through
middle of bracket slots
and drill 13/32" holes
Figure 5
Post Bracket
Assembly
C Clamp
riz
L Ho
LEVE
r
embe
ss M
Cro
ontal
Post Bracket
Assembly
Operator MUST be level
3/8"-16 x 6"
Carriage Bolt
Fence Post
Gate In CLOSED Position
Gate Bracket
C Clamp Horizontal Center of
Gate Cross Member
11
CONTROL BOX MOUNTING
1. Remove PCB and batteries.
2. Determine the spacing required for mounting and select the
proper holes to be used for mounting (Figure 1).
3. Knockout plastic from holes using screw driver.
4. Place box up against the mounting surface. Insert the screws
through the mounting holes in back and secure in place
(Figure 2).
Mounting Post
Figure 2
4" (10 cm) Screw Spacing (4)
Figure 1
E-Box
6" (15 cm) Screw
Spacing (4)
Mounting screw
4 places
2-1/2" (6.3 cm) Screw Spacing (4)
CONTROL BOX MOUNTING WITH U-BOLTS
(OPTIONAL KIT)
Figure 3
Mounting Post
1. Remove PCB and batteries.
2. Determine the spacing required for mounting and select the
proper holes to be used for mounting (Figure 1).
3. Knockout plastic from holes using screw driver.
4. Center the box up against the mounting post. Insert the U-bolts
through the mounting holes in back (Figure 3).
5. Once the U-Bolts are in place, insert the rubber washer,
followed by the metal washer and 1/4"-20 Nut (Figure 3).
6. Tighten the assembly down snug after positioning it as desired.
Optional kits available are:
50-19509 6" (15 cm) Post Mounting
50-19511 4" (10 cm) Post Mounting
50-19512 2-1/2" (6.3 cm) Post Mounting
U-Bolt (2)
1/4" Washer (4)
1/4"-20
Hex Nut (4)
1/4" Washer (4)
12
NING
WARNING
W
IRING
ION
WARNING
To reduce the risk of SEVERE INJURY or DEATH:
• ANY maintenance to the operator or in the area near the
operator MUST not be performed until disconnecting the
electrical power and locking-out the power via the operator
power switch. Upon completion of maintenance the area MUST
be cleared and secured, at that time the unit may be returned
to service.
• Disconnect power at the fuse box BEFORE proceeding.
Operator MUST be properly grounded and connected in
accordance with local electrical codes. NOTE: The operator
should be on a separate fused line of adequate capacity.
• ALL electrical connections MUST be made by a qualified
individual.
• DO NOT install ANY wiring or attempt to run the operator
without consulting the wiring diagram. We recommend that
you install an optional reversing edge BEFORE proceeding with
the control station installation.
• ALL power wiring should be on a dedicated circuit and well
protected. The location of the power disconnect should be
visible and clearly labeled.
• ALL power and control wiring MUST be run in separate
conduit.
• BEFORE installing power wiring or control stations be sure to
follow ALL specifications and warnings described below.
Failure to do so may result in SEVERE INJURY to persons
and/or damage to operator.
All power wiring should be on a dedicated circuit and well protected.
NOTE: Calculated using NEC guidelines. Local codes and conditions must be reviewed for suitability of wire installation.
The transformer is tie-wrapped at the factory for shipping. The
transformer can be plugged into a receptacle external to the
control box. You can run low voltage wire between the
transformer and control box. This will create more space in the
control box for accessories.
Alternatively, you can connect 120Vac directly to the box, and
plug the transformer to the receptacle inside the control box.
120VAC POWER WIRE
(STRANDED COPPER WIRE)
Wire Gauge
16
10
Length
100' (30 m)
1000' (305 m)
CONNECT ARM TO CONTROL BOX
Connect the wires from the operator to connector P17 for the
Gate 1 operator as shown in the wiring diagram on page 26.
Connect the proper color coded wire to the terminal pin as
indicated. Use supplied strain relief.
If connecting a second arm, follow the same instructions on
connector P16.
24VAC TRANSFORMER
(STRANDED COPPER WIRE)
Wire Gauge
16
14
12
EARTH GROUND ROD INSTALLATION (OPTIONAL)
When installing the optional earth ground rod, disconnect and
remove the green/yellow ground wire connected to the screw
terminal of the printed circuit
board. For proper operation,
Control Box
the earth ground rod should
not be connected to the
ground of your power wiring.
Ensure the power wiring
ground connection remains
securely connected to the
Earth Ground
12 gauge
Installation
green screw on the outlet
wire
(Optional)
plate.
The earth ground rod must be
8 ft.
located within 3 feet (0.9 m) of
(2.4 m)
the operator. Use the proper
type earth ground rod for your
area.
Attach earth ground rod wire to the screw terminal of the printed
circuit board marked .
Length
100' (30 m)
500' (152 m)
1000' (305 m)
Motor
Wiring
WARNING
Control
Wiring
Power
Wiring
CAUTION
To AVOID damaging gas, power or other underground utility
lines, contact underground utility locating companies BEFORE
digging more than 18" (46 cm) deep.
WARNING
CAUTION
To AVOID damaging plug-in transformer, it MUST be enclosed
in a suitable weatherproof enclosure and provided with proper
weatherproof fixtures.
13
WARNING
CONTROL WIRING
CAUTION
P2
P1
CLOSE
EDGE
Ø14GPØ89ØE
Ø14LGØ89ØE
Ø14SKØ89ØE
R2Ø7
J1
NO
Z2Ø
R227
C
K5
MAGLOCK
To reduce the risk of FIRE or INJURY to persons, use ONLY
Chamberlain part #K74-30762 for replacement batteries.
R223
J19
K6
ALARM
OPEN EDGE/
PHOTO
NO
L1
J18
R224
C
S8
LEARN
XMITTER
10A 32V
2
GATE 1
1 2 3 4 5
OFF
OFF
SINGLE
NO
NO
R2
R1
O
N
1
NC
Z1
ON
ON
DUAL
NC
NC
Z22
R92
U4
SAVE
MAGLOCK
MODE
EDGE
PHOTO
Z9
OPEN
PHOTO
S1
F3
R91
BRN
D1Ø
GRN
R94
K2
Z8
WHT
CLOSE
PHOTO
DIAGNOSTIC
YEL
R93
BLU
GATE 1
RED
K1 Q9
Z12
SET
OPEN
LIMIT
SET
CLOSE
LIMIT
R9Ø
ACCESSORY
POWER
LEARN
LIMITS
GATE 2
24V
BRN
BIPART
DELAY
FORCE
R1Ø1
24V
TIMER
RUNNING
COM OVLD
OVLD
CONTROL
INPUTS
TIMER TO SINGLE
BUTTON
CLOSE
R1ØØ
SWITCHED
ACCESSORY
POWER
OPEN
SINGLE BUTTON
F4
GRN
RESET
ACCESSORY
OVLD
10A 32V
WHT
BATT 2 B
ATT 1
STOP
K4
YEL
MIN
MAX
OFF
MAX
OFF
MAX
COM
F5
BLU
COM
D21
RED
POWER
R35
D9
K3
D8
GATE 2
C12
D27 Z3
F7
Z4
Q22
C13
D22
LOOP
INPUTS
C4
SHADOW
U3
INTERRUPT
C11
C2
R196
F6
24 VAC/
SOLAR
INPUT
J4
COM
CHGR
OVLD
D15
R4
F2
MOV2
R9
MOV1
D4
D1
C64
JMPR1
JMPR2
D2
U2
FUSE
OPEN
BATT 2
BATT 1
D6
DB1
F1 2ØA 32V
BATTERY
The main source of power for the operator is the batteries. The
batteries can be charged in circuit by using a charging
transformer or solar panels.
24 VAC/
SOLAR
INPUT
J4
MOV2
USE DEDICATED CIRCUIT
CHARGING
The 24Vac input can accept a charging transformer
(26Vac, 29VA or 36Vdc, 40VA).
OR
SOLAR PANELS
Optional solar panels may be used to charge the batteries.
SOLKIT12V
(UL Listed with Class 2 outputs)
WARNING
CAUTION
To AVOID damaging plug-in transformer, it MUST be enclosed
in a suitable weatherproof enclosure and provided with proper
weatherproof fixtures.
To AVOID damaging control board, DO NOT use the solar panel
and the plug-in transformer at the same time.
14
BASIC CONTROL BOARD SETUP
19
20
26
17
1
P2
R223
P1
CLOSE
EDGE
J19
Ø14GPØ89ØE
Ø14LGØ89ØE
Ø14SKØ89ØE
K6
ALARM
14
J1
NO
Z2Ø
R227
C
K5
MAGLOCK
13
OPEN EDGE/
PHOTO
NO
L1
J18
S8
OFF
OFF
SINGLE
NO
NO
LEARN
XMITTER
R1
10A 32V
2
GATE 1
1 2 3 4 5
Z1
O
N
1
R2
ON
ON
DUAL
NC
NC
Z22
R92
U4
SAVE
MAGLOCK
MODE
EDGE
PHOTO
Z9
OPEN
PHOTO
S1
F3
3
R224
C
NC
18
2
R2Ø7
4
R91
BRN
D1Ø
GRN
R94
K2
Z8
WHT
12
CLOSE
PHOTO
DIAGNOSTIC
YEL
5
R93
BLU
GATE 1
RED
K1 Q9
Z12
SET
OPEN
LIMIT
SET
CLOSE
LIMIT
R9Ø
ACCESSORY
POWER
11*
TIMER
RUNNING
BRN
BIPART
DELAY
FORCE
R1Ø1
6*
24V
GATE 2
24V
COM OVLD
OVLD
SWITCHED
ACCESSORY
POWER
CONTROL
INPUTS
TIMER TO SINGLE
BUTTON
CLOSE
R1ØØ
OPEN
7
RESET
ACCESSORY
OVLD
10A 32V
WHT
22
SINGLE BUTTON
F4
GRN
10
LEARN
LIMITS
STOP
K4
YEL
MIN
MAX
OFF
MAX
OFF
MAX
COM
F5
BLU
COM
D21
RED
D9
K3
D8
GATE 2
POWER
R35
C12
D27 Z3
F7
Z4
Q22
C13
D22
LOOP
INPUTS
C4
SHADOW
U3
21
R196
C2
F6
24 VAC/
SOLAR
INPUT
J4
F2
MOV2
R9
MOV1
D1
JMPR1
BATT 2
BATT 1
D6
DESCRIPTION
Connector P1
Connector P6
Connector P8
Connector P7
Connector P9
Connector P12
Connector P10
Connector P11
Connector P5
Connector P16
Connector P13
Connector P17
Connector P14
FUSE
OPEN
D2
U2
9
F1 20A 32V
D4
C64
JMPR2
DB1
ITEM
1
2
3
4
5
6
7
8
9
10
11
12
13
COM
CHGR
OVLD
D15
R4
8
INTERRUPT
C11
23
24
FUNCTION
Antenna Input
Close Edge
Open Edge/Photo
Open Photo
Close Photo
Switched Accessory Power*
Control Inputs
Loop Inputs
24Vac/Solar Input
Gate 2
Accessory Power*
Gate 1
Maglock/Solenoid
ITEM
14
15
16
17
18
19
20
21
22
23
24
25
26
*Maximum 300 mA combined output
15
25
DESCRIPTION
Connector P15
Connector
Connector
Dip Switch
Pushbutton
Pushbuttons
Pushbutton
Pushbuttons
Pushbutton
Potentiometer
Potentiometer
Potentiometer
Connector
16 15
FUNCTION
Alarm
Battery 1
Battery 2
S1
Learn Xmitter - Program Remote
Gate 1 - Jog Learn Limit
Learn Limits
Gate 2 - Jog Learn Limit
Single Button
Force
Bi-Part Delay
Timer to Close
Receiver
SET DIP SWITCH FOR GATE TYPE
1. The Save switch must be set to the OFF position prior to
setting or changing the switches.
2. Set switch to Single for single gate installation. For Dual
(Gate 1 and 2) installation set switch on Dual.
3. Set the Save switch to ON to save the setting.
NOTE: When setting switches S2-5, the Save switch must be in
the OFF position prior to setting or changing switches for the
change to be saved.
P1
CLOSE
EDGE
Ø14GPØ89ØE
Ø14LGØ89ØE
Ø14SKØ89ØE
K6
ALARM
R2Ø7
J1
NO
Z2Ø
R227
C
K5
MAGLOCK
ON
ON
DUAL
NC
NC
SAVE
MAGLOCK
MODE
EDGE
PHOTO
S1
OPEN EDGE/
PHOTO
NO
1 2 3 4 5
R223
J19
O
N
P2
OFF
OFF
SINGLE
NO
NO
L1
J18
R224
C
S8
LEARN
XMITTER
10A 32V
2
GATE 1
1 2 3 4 5
OFF
OFF
SINGLE
NO
NO
R2
R1
O
N
1
NC
Z1
ON
ON
DUAL
NC
NC
Z22
R92
U4
SAVE
MAGLOCK
MODE
EDGE
PHOTO
Z9
OPEN
PHOTO
S1
F3
R91
BRN
D1Ø
GRN
R94
K2
Z8
WHT
CLOSE
PHOTO
DIAGNOSTIC
YEL
R93
BLU
GATE 1
RED
K1 Q9
Z12
SET
OPEN
LIMIT
SET
CLOSE
LIMIT
R9Ø
GATE 2
BIPART
DELAY
FORCE
R1Ø1
COM OVLD
OVLD
TIMER TO
CLOSE
SWITCHED
ACCESSORY
POWER
OFF
OFF
SINGLE
NO
NO
CONTROL
INPUTS
SINGLE
BUTTON
OPEN
R1ØØ
SINGLE BUTTON
F4
GRN
RESET
ACCESSORY
OVLD
10A 32V
WHT
STOP
K4
YEL
MIN
MAX
OFF
MAX
OFF
MAX
COM
F5
BLU
COM
D21
RED
D9
D8
GATE 2
POWER
R35
K3
C12
D27 Z3
F7
Z4
Q22
C13
D22
LOOP
INPUTS
C4
SHADOW
U3
C11
C2
COM
CHGR
OVLD
R196
F6
24 VAC/
SOLAR
INPUT
J4
ON
ON
DUAL
NC
NC
INTERRUPT
D15
R4
1 2 3 4 5
24V
BRN
24V
TIMER
RUNNING
O
N
ACCESSORY
POWER
LEARN
LIMITS
F2
MOV2
R9
MOV1
D4
D1
C64
D2
U2
FUSE
OPEN
BATT 2
BATT 1
16
1 2 3 4 5
D6
OFF
OFF
SINGLE
NO
NO
O
N
JMPR1
JMPR2
DB1
F1 20A 32V
ON
ON
DUAL
NC
NC
COMPATIBLE REMOTES - 315MHz
PROGRAMMING REMOTE
1. Press LEARN XMITTER button (LED will light up).
2. Press remote button, the LED will flash, alarm output will
activate twice.
3. Repeat steps 1 and 2 until all remotes are programmed
(50 remotes maximum).
NOTE: For highest level of security, we recommend the
Security✚® line of products.
Security✚® Remotes
370LM
371LM
372LM
373LM
374LM
Passport™ Remote
CPT13
CPT23
CPT33
Security✚® Keyless Entry
377LM
LEARN
XMITTER
R1
2
P2
P1
J19
Ø14GPØ89ØE
Ø14LGØ89ØE
Ø14SKØ89ØE
K6
ALARM
J1
NO
C
K5
MAGLOCK
NO
L1
C
Z1
R1
LEARN
XMITTER
10A 32V
2
GATE 1
OFF
OFF
SINGLE
NO
NO
1 2 3 4 5
S8
R2
O
N
1
NC
ON
ON
DUAL
NC
NC
SAVE
MAGLOCK
MODE
EDGE
PHOTO
S1
F3
BRN
GRN
D1Ø
K2
WHT
DIAGNOSTIC
YEL
LiftM
BLU
ast
er
GATE 1
RED
K1 Q9
Z12
SET
OPEN
LIMIT
SET
CLOSE
LIMIT
LEARN
LIMITS
NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or
modifications of this receiver and/or transmitter are prohibited, except for changing the
code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to
the following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
WIRE STOP BUTTON (OPTIONAL)
A jumper wire is factory installed between the stop and common input.
Stop (N/C) - Stop only (does not reset alarm).
P2
R223
P1
CLOSE
EDGE
J19
Ø14GPØ89ØE
Ø14LGØ89ØE
Ø14SKØ89ØE
K6
ALARM
R2Ø7
J1
NO
Z2Ø
R227
C
K5
MAGLOCK
OPEN EDGE/
PHOTO
NO
L1
J18
R224
C
S8
LEARN
XMITTER
10A 32V
2
GATE 1
1 2 3 4 5
OFF
OFF
SINGLE
NO
NO
R2
R1
O
N
1
NC
Z1
ON
ON
DUAL
NC
NC
Z22
R92
U4
SAVE
MAGLOCK
MODE
EDGE
PHOTO
Z9
OPEN
PHOTO
S1
F3
R91
BRN
D1Ø
GRN
R94
K2
CONTROL
INPUTS
Z8
WHT
CLOSE
PHOTO
DIAGNOSTIC
YEL
R93
BLU
GATE 1
OPEN
RED
K1 Q9
Z12
SET
OPEN
LIMIT
SET
CLOSE
LIMIT
R9Ø
ACCESSORY
POWER
LEARN
LIMITS
GATE 2
24V
TIMER
RUNNING
BIPART
DELAY
FORCE
R1Ø1
BRN
24V
COM OVLD
OVLD
CONTROL
INPUTS
TIMER TO SINGLE
BUTTON
CLOSE
R1ØØ
SINGLE BUTTON
SWITCHED
ACCESSORY
POWER
RESET
OPEN
SINGLE BUTTON
F4
GRN
RESET
ACCESSORY
OVLD
10A 32V
WHT
STOP
STOP
K4
YEL
MIN
MAX
OFF
MAX
OFF
MAX
COM
F5
BLU
D21
RED
POWER
R35
D9
K3
D8
GATE 2
C12
D27 Z3
F7
Z4
Q22
COM
COM
C13
D22
LOOP
INPUTS
C4
COM
SHADOW
U3
INTERRUPT
C11
D15
R4
C2
R196
F6
24 VAC/
SOLAR
INPUT
J4
POWER
COM
CHGR
OVLD
F2
MOV2
R9
MOV1
C64
JMPR1
JMPR2
D2
U2
FUSE
OPEN
BATT 2
BATT 1
D6
DB1
F1 20A 32V
D4
D1
17
OPTIONAL CONTROL DEVICES
SBC (Single Button Control) Input (N/O)
This input will command the gate to
OPEN / STOP / CLOSE / STOP in sequence.
Reset Control Input (N/O)
The control box has a factory installed internal reset button.
These terminals are intended for use with a single reset button
that is installed within line of sight of the gate. This input
functions to reset the alarms. This input will NOT stop the gate.
Open (N/O) - Opens only or reverses a closing gate.
Open Input and Exit Loop
These terminals are intended for use as a general open control.
Accessories such as telephone entry systems, radio receivers
(open only applications), exit loop detectors, keypads and 7-day
timers may be wired to this input.
PR
ESE
NC
RE E
LAY
2
EXIT LOOP
AND/OR
CONTROL
INPUTS
OPEN
SINGLE BUTTON
SINGLE
BUTTON
RESET
STOP
COMMON
COM
COM
AND/OR
POWER
COMMON
RESET
P2
R223
P1
CLOSE
EDGE
J19
Ø14GPØ89ØE
Ø14LGØ89ØE
Ø14SKØ89ØE
R2Ø7
J1
NO
Z2Ø
R227
C
K5
MAGLOCK
OPEN EDGE/
PHOTO
NO
L1
J18
R224
C
S8
LEARN
XMITTER
10A 32V
2
GATE 1
1 2 3 4 5
OFF
OFF
SINGLE
NO
NO
R2
R1
O
N
1
NC
Z1
ON
ON
DUAL
NC
NC
Z22
R92
U4
SAVE
MAGLOCK
MODE
EDGE
PHOTO
Z9
OPEN
PHOTO
S1
F3
R91
BRN
D1Ø
GRN
R94
K2
Z8
WHT
CLOSE
PHOTO
DIAGNOSTIC
YEL
R93
BLU
GATE 1
RED
K1 Q9
Z12
SET
OPEN
LIMIT
SET
CLOSE
LIMIT
R9Ø
ACCESSORY
POWER
LEARN
LIMITS
GATE 2
24V
BRN
BIPART
DELAY
FORCE
R1Ø1
24V
TIMER
RUNNING
COM OVLD
OVLD
R1ØØ
SWITCHED
ACCESSORY
POWER
CONTROL
INPUTS
TIMER TO SINGLE
BUTTON
CLOSE
OPEN
SINGLE BUTTON
F4
GRN
RESET
ACCESSORY
OVLD
10A 32V
WHT
STOP
K4
YEL
MIN
MAX
OFF
MAX
OFF
MAX
COM
F5
BLU
COM
D21
RED
D9
K3
D8
GATE 2
POWER
R35
C12
D27 Z3
F7
Z4
Q22
C13
D22
LOOP
INPUTS
C4
SHADOW
U3
INTERRUPT
C11
C2
R196
F6
24 VAC/
SOLAR
INPUT
J4
COM
CHGR
OVLD
D15
R4
F2
MOV2
R9
MOV1
F1 20A 32V
D4
D1
C64
JMPR1
JMPR2
D2
U2
FUSE
OPEN
BATT 2
BATT 1
D6
DB1
62
5X
DE
MA
COMMON
K6
5X
62
SE
NS
FRE
EQQ
OPEN
ALARM
ota
ras
Sa
18
IN
A
US
LOOP INPUTS (P11)
Shadow Loop Input Terminal and Common
This input protects cars by preventing the gate from moving off
of the open or close limit when the shadow loop input is active.
Interrupt Loop Input Terminal and Common
This input functions to reverse a closing gate to the open limit.
Latching this input will reset the timer to close.
LOOP
INPUTS
SHADOW LOOP
SHADOW
INTERRUPT LOOP
INTERRUPT
COMMON LOOP
COM
CHGR
OVLD
F1 20A 32V
FUSE
OPEN
BATT 2
BATT 1
PR
ESE
NC
RE E
LAY
2
o
ras
Sa
ta
5X
62
SE
6 2 NS
5X
FRRE
EQQ
IN
DE
MA
PHOTO/EDGE INPUTS (P6-7-8 and 9)
Terminal P6 – Close Safety Edge
This input will reverse a closing gate. It will disable the
Timer-to-Close if that feature has been enabled. Activating this
input while the gate is opening will have no effect.
Order part number LA400-BOX to enclose safety electronics.
CLOSE
EDGE
Terminal P8 – Open Safety Edge/Photo Eye
If an Open Edge device or a Retro-Reflective Photo Eye has been
connected to Terminal P8, then this input will reverse an opening
gate for 2 seconds then stop. Activating this input with an Open
Edge device or a Retro-Reflective Photo Eye connected to
Terminal P8 while the gate is closing will have no effect.
If a Chamberlain Pulsing Photo Eye has been connected to
Terminal P8, then this input will pause an opening gate until the
obstruction has been removed. Upon removing the obstruction,
the gate will continue to open. Activating this input with a
Chamberlain Pulsing Photo Eye connected to Terminal P8 while
the gate is closing will have no effect.
OPEN EDGE
PHOTO
BL U
Terminal P7 – Open Safety Photo Eye
This input will pause an opening gate until the obstruction has
been removed. Upon removing the obstruction, the gate will
continue to open. Activating this input while the gate is closing
will have no effect.
BRO
BRO
E
BL U
WN
E
OPEN
PHOTO
BROWN
BLUE
BROWN
BLUE
Terminal P9 – Close Safety Photo Eye
This input will reverse a closing gate to the open limit. Activating
this input while the gate is opening will have no effect. The
Timer-to-Close will not reactivate at the open limit.
CLOSE
PHOTO
BROWN
BLUE
BROWN
BLUE
19
WN
A
US
SAFETY ACCESSORIES FOR SECONDARY ENTRAPMENT PROTECTION
The following devices are acceptable for Safety Accessories for secondary entrapment protection. These devices have been
tested with the LA400 to meet the requirements of UL325 and UL991.
PHOTO-ELECTRIC CONTROLS
MODEL
DESCRIPTION
VOLTAGE
CPS-LN4
Emitter, receiver and mounting brackets - 30' (9 m) Ranges
AOMRON
24 Volt Photocell/Electric Eye - 30' (9 m) Ranges
+24Vdc
SENSING EDGES
MODEL
DESCRIPTION
VOLTAGE
G65MG0204
Miller MG020 2-wire electric edge for gates. Sensitized on three sides. Requires
mounting channel.
+24Vdc and 24Vac
G65MG0205
Miller MG020 2-wire electric edge for gates. Sensitized on three sides. Requires
mounting channel.
+24Vdc and 24Vac
G65MGR205
Miller MGR20 2-wire electric edge in 5' (1.5 m) lengths for 2" (5 cm) round post.
+24Vdc and 24Vac
G65MGS205
Miller MGR20 2-wire electric edge in 5' (1.5 m) lengths for 2" (5 cm) square post.
+24Vdc and 24Vac
MAGLOCK/ALARM
Alarm
Flashing Strobe
(optional)
The alarm output provides a switch to turn on an external flashing device
and/or an internal audible alarm, when activated. The alarm is activated
by two sequential obstructions in either direction.
Siren
(optional)
Maglock
When enabled, the maglock output is activated (energized) while the gate
is in motion.
Fault Alarm
P2
R223
P1
CLOSE
EDGE
J19
Ø14GPØ89ØE
Ø14LGØ89ØE
Ø14SKØ89ØE
K6
ALARM
J1
NO
R2Ø7
Z2Ø
R227
C
K5
MAGLOCK
OPEN EDGE/
PHOTO
NO
Solenoid Lock
(optional)
L1
J18
R224
C
S8
LEARN
XMITTER
10A 32V
2
GATE 1
1 2 3 4 5
OFF
OFF
SINGLE
NO
NO
R2
R1
O
N
1
NC
Z1
ON
ON
DUAL
NC
NC
Z22
R92
U4
SAVE
MAGLOCK
MODE
EDGE
PHOTO
Z9
OPEN
PHOTO
S1
F3
R91
BRN
D1Ø
GRN
R94
K2
Z8
WHT
Maglock
(optional)
CLOSE
PHOTO
DIAGNOSTIC
YEL
R93
BLU
GATE 1
RED
K1 Q9
Z12
SET
OPEN
LIMIT
SET
CLOSE
LIMIT
R9Ø
ACCESSORY
POWER
LEARN
LIMITS
GATE 2
24V
BRN
TIMER
RUNNING
BIPART
DELAY
FORCE
R1Ø1
Accessory
Power
24V
COM OVLD
OVLD
CONTROL
INPUTS
TIMER TO SINGLE
BUTTON
CLOSE
R1ØØ
SWITCHED
ACCESSORY
POWER
OPEN
SINGLE BUTTON
F4
GRN
RESET
ACCESSORY
OVLD
10A 32V
WHT
STOP
K4
YEL
MIN
MAX
OFF
MAX
OFF
MAX
COM
F5
BLU
COM
D21
RED
D9
D8
GATE 2
POWER
R35
K3
C12
D27 Z3
F7
Z4
Q22
C13
D22
LOOP
INPUTS
C4
SHADOW
U3
INTERRUPT
C11
C2
R196
F6
24 VAC/
SOLAR
INPUT
J4
COM
CHGR
OVLD
D15
R4
F2
MOV2
R9
MOV1
D4
D1
C64
JMPR1
JMPR2
D2
U2
FUSE
OPEN
BATT 2
BATT 1
D6
DB1
F1 20A 32V
Auxillary Output Power for Optional Devices
(2) +24Vdc Outputs (P13 and P12) have
been provided for optional devices
20
FORCE AND TIMER TO CLOSE
FORCE CONTROL
Set the force control such that the unit will
complete a full cycle of gate travel but will
reverse off an obstruction without applying
an unreasonable amount of force.
MIN
MAX
BI-PART DELAY
Set the BI-PART DELAY to
desired setting. The range is 0 to
8 seconds, 0 seconds is OFF.
OFF
TIMER TO CLOSE ENABLE
Set the TIMER TO CLOSE to
desired setting. The range is 0 to
180 seconds, 0 seconds is OFF.
MAX
OFF
MAX
PROGRAM LIMITS
P2
R223
P1
1. Turn Bi-Part switch to desired setting. Set to “Off” for single
gate applications.
2. Press the “LEARN LIMITS” button.
3. The “SET OPEN LIMIT” LED will blink.
4. Use the “Gate 1” buttons to move Gate 1 to the desired open
position. Repeat if Gate 2 is present using “Gate 2” buttons.
5. Press the “LEARN LIMITS” button to set the Open Limit for
gate(s).
6. The “SET OPEN LIMIT” LED will turn off. The “SET CLOSE
LIMIT” LED will blink.
7. Use the “Gate 1” buttons to move Gate 1 to the desired close
position. Repeat if Gate 2 is present using “Gate 2” buttons.
8. Press the “LEARN LIMITS” button to set the close limit for
gate(s).
9. The “SET CLOSE LIMIT” LED will turn off. The limits are set.
10. Using programmed remote or single button input (SBC) run
the gate(s) from the close limit to the open limit. After
reaching the open limit, run the gate(s) to the close limit.
This will learn the force in the open and close direction.
11. If the learned force is not high enough, manually adjust the
force control as described above.
NOTE: After final limit adjustments the gate can be opened
slightly further by increasing the distance between center of gate
hinge and the gate bracket by 1" (25.4 mm). Do not move the
post bracket assembly.
CLOSE
EDGE
J19
Ø14GPØ89ØE
Ø14LGØ89ØE
Ø14SKØ89ØE
K6
ALARM
R2Ø7
J1
NO
Z2Ø
R227
C
K5
MAGLOCK
OPEN EDGE/
PHOTO
NO
L1
J18
R224
C
S8
LEARN
XMITTER
10A 32V
2
GATE 1
1 2 3 4 5
OFF
OFF
SINGLE
NO
NO
R2
R1
O
N
1
NC
Z1
ON
ON
DUAL
NC
NC
Z22
R92
U4
SAVE
MAGLOCK
MODE
EDGE
PHOTO
Z9
OPEN
PHOTO
S1
F3
R91
BRN
D1Ø
GRN
R94
K2
Z8
WHT
CLOSE
PHOTO
DIAGNOSTIC
YEL
R93
BLU
GATE 1
RED
K1 Q9
Z12
SET
OPEN
LIMIT
SET
CLOSE
LIMIT
R9Ø
ACCESSORY
POWER
LEARN
LIMITS
GATE 2
24V
BIPART
DELAY
FORCE
R1Ø1
BRN
24V
TIMER
RUNNING
COM OVLD
OVLD
R1ØØ
SWITCHED
ACCESSORY
POWER
CONTROL
INPUTS
TIMER TO SINGLE
BUTTON
CLOSE
OPEN
SINGLE BUTTON
F4
GRN
RESET
ACCESSORY
OVLD
10A 32V
WHT
STOP
K4
YEL
MIN
MAX
OFF
MAX
OFF
MAX
COM
F5
BLU
COM
D21
RED
D9
K3
D8
GATE 2
POWER
R35
C12
D27 Z3
F7
Z4
Q22
C13
D22
LOOP
INPUTS
C4
SHADOW
U3
INTERRUPT
C11
C2
R196
F6
24 VAC/
SOLAR
INPUT
J4
F2
MOV2
R9
MOV1
JMPR1
D2
U2
D6
DIAGNOSTIC
GATE 1
SET
CLOSE
LIMIT
LEARN
LIMITS
GATE 2
FORCE
NOTE: Any following SBC or remote inputs will move the gate.
21
F1 20A 32V
D4
D1
C64
JMPR2
DB1
SET
OPEN
LIMIT
COM
CHGR
OVLD
D15
R4
FUSE
OPEN
BATT 2
BATT 1
DIP SWITCH SETTINGS
P2
R223
P1
CLOSE
EDGE
J19
Ø14GPØ89ØE
Ø14LGØ89ØE
Ø14SKØ89ØE
K6
ALARM
R2Ø7
J1
NO
Z2Ø
R227
C
K5
MAGLOCK
OPEN EDGE/
PHOTO
NO
L1
J18
C
2
GATE 1
OFF
OFF
SINGLE
NO
NO
ON
ON
DUAL
NC
NC
SAVE
MAGLOCK
MODE
EDGE
PHOTO
S1
F3
U4
Z22
R92
OFF
OFF
SINGLE
NO
NO
Z9
OPEN
PHOTO
R91
BRN
D1Ø
GRN
R94
K2
Z8
WHT
CLOSE
PHOTO
DIAGNOSTIC
YEL
R93
BLU
GATE 1
RED
K1 Q9
Z12
ACCESSORY
POWER
R9Ø
SET
OPEN
LIMIT
SET
CLOSE
LIMIT
ON
ON
DUAL
NC
NC
SAVE
MAGLOCK
MODE
EDGE
PHOTO
S1
LEARN
LIMITS
GATE 2
1 2 3 4 5
LEARN
XMITTER
O
N
R1
1 2 3 4 5
S8
R2
10A 32V
O
N
1
NC
Z1
R224
24V
TIMER
RUNNING
COM OVLD
OVLD
SWITCHED
ACCESSORY
POWER
O
N
O
N
O
N
O
N
1 2 3 4 5
O
N
OFF
OFF
SINGLE
O
N
1 2 3 4 5
OFF
OFF
SINGLE
EDGE NO
1 2 3 4 5
EYE NO
22
1 2 3 4 5
EYE INPUT
This switch (S1-5) differentiates between N/O and N/C
dry contact photoelectric eye inputs.
NOTE: Pulsing Chamberlain photoelectric eyes will
automatically learn in N/O mode.
1 2 3 4 5
1 2 3 4 5
OFF
OFF
SINGLE
NO
NO
SAFETY INPUTS
Swing gates allow four safety inputs. A DIP switch is
required for determining between N/O and N/C edges and
N/O and N/C eyes.
EDGE INPUT
Set switch (S1-4) to the following settings:
N/O Edge (Active Close) = 8.2K, 10K Edge, N/O dry
contact edge
N/C Edge (Active Open) = N/C dry contact edge
NOTE: Monitored Edges should be set in the N/O
position, as the activation condition is shorting the
terminals.
1 2 3 4 5
OFF
MAG DELAY
ON
O
N
MODE DUAL/SINGLE
This switch (S1-3) sets the mode as Dual or Single
(See Programming section for mode).
1 2 3 4 5
MAG DELAY ENABLE
This switch (S1-2) enables the Mag Lock feature. On an
open command there will be a .5 second delay before the
motor starts, to allow the Maglock to release.
SAVE
OFF
O
N
SAVE SWITCH S1-1
This switch (S1-1) is used to save the settings for
switches 2 through 5.
NOTE: When setting switches S2-5 the save switch must
be in the off position prior to setting or changing switches
for the change to be saved.
ON
ON
DUAL
NC
ON
ON
DUAL
NC
SAVE
ON
ON
MAG DELAY
OFF
ON
ON
DUAL
NC
NC
WARNING
O P E R AT I O N A N D M A I N T E N A N C E
IMPORTANT SAFETY INSTRUCTIONS
WARNING
To reduce the risk of SEVERE INJURY or DEATH:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. NEVER let children operate or play with gate controls.
Keep the remote control away from children.
3. ALWAYS keep people and objects away from the gate.
NO ONE SHOULD CROSS THE PATH OF THE MOVING
GATE.
4. Test the gate operator monthly. The gate MUST reverse
on contact with a rigid object or stop when an object
activates the non-contact sensors. After adjusting the
force or the limit of travel, retest the gate operator.
Failure to adjust and retest the gate operator properly
can increase the risk of INJURY or DEATH.
5. Use the emergency release ONLY when the gate is not
moving.
6. KEEP GATES PROPERLY MAINTAINED. Read the
owner’s manual. Have a qualified service person make
repairs to gate hardware.
7. The entrance is for vehicles ONLY. Pedestrians MUST
use separate entrance.
8. Disconnect ALL power BEFORE performing ANY
maintenance.
9. ALL maintenance MUST be performed by a LiftMaster
professional.
10.
SAVE THESE INSTRUCTIONS.
MAINTENANCE
CHECK AT LEAST ONCE EVERY
TASK
MONTH
External entrapment
protection systems
Check for proper operation
Gate warning signs
Make sure they are present
Manual disconnect
Check and operate
Gate
Inspect for wear or damage
Accessories
Check all for proper operation
Electrical
Inspect all wire connections
Frame bolts
Check for tightness
Total unit
Inspect for wear or damage
NOTES:
1. Disconnect power before servicing.
2. Severe or high cycle usage will require more frequent
maintenance checks.
3. Inspection and service should always be performed anytime a
malfunction is observed or suspected.
4. When servicing, please do some “house cleaning” of the
operator and the area around the operator. Pick up any debris
in the area. Clean the operator as needed.
5. It is suggested that while at the site voltage readings be taken
at the operator. Using a Digital Voltmeter, verify that the
incoming voltage to the operator it is within ten percent of the
operators rating.
3 MONTHS
6 MONTHS
12 MONTHS
Complete Check Out
DESCRIPTION
WARNING
CAUTION
To reduce the risk of FIRE or INJURY to persons, use ONLY
Chamberlain part #K74-30762 for replacement batteries.
23
WARNING
WARNING
WARNING
CAUTION
To avoid SERIOUS personal INJURY or DEATH from
electrocution, DISCONNECT electrical power to operator
BEFORE proceeding.
To reduce the risk of FIRE or INJURY to persons, use ONLY
Chamberlain part #K74-30762 for replacement batteries.
BATTERY REPLACEMENT
1. Disconnect power to operator.
2. Open the control box cover.
3. Remove all quick connect terminals in use to the control
board. Remember location of all wire connections for
reinstallation.
4. Remove control board and mounting plate.
5. Disconnect terminals leads to both batteries.
6. Replace both batteries and connect red wires to the positive
(+) terminals (red). Connect black wires to the negative (-)
terminals (black).
7. Install control board and mounting plate.
8. Reconnect all quick connect terminals to the control board.
9. Close cover of control box.
10. Reconnect power to operator.
Batteries
Control Board
and Mounting Plate
MANUAL RELEASE
The drive mechanism can be released. The gate can then be
operated manually (power failure). With a new drive mechanism,
the release action may sometimes feel stiff/jerky. This is normal
and has no effect on function.
Release
1. Insert the key into the lock.
2. Turn the key counter-clockwise 180°.
3. Turn the release lever counter-clockwise 180°.
4. Done! Operator is in manual mode.
Engage
1. Turn the release lever clockwise 180°. This engages the
motor.
2. Turn the key clockwise 180°. This locks the release lever.
3. Remove the key and store in a safe place.
4. Done! Back in automatic mode.
24
L A 4 0 0 S W I N G G AT E A C C E S S O R I E S
SOLKIT12V
Solar Panel Kit with battery box:
Improved solar solution with battery box
(battery not included).
02101
1-Button Station:
Steel enclosure wired station will allow for a
Open, Close, Stop command of the gate.
377LM
SECURITY✚® Keyless Entry:
Enables homeowner to operate gate by entering
a password on a specially designed keyboard.
Also can add a temporary password for visitors
or service persons. This temporary password
can be limited to a programmable number of
hours or entries.
EMX202
Vehicle Detecting Driveway Probe:
One piece outdoor buried vehicle motion
detector with sensing probe is housed in a
small relay type housing. Provides for free exit.
GC824
Gate Solenoid Lock:
Heavy all steel construction. Failsafe operation
keeps gate locked if power is lost. Can be
welded onto gate or post. 115V operation,
solenoid-activated release. Can be released
in case of an emergency.
GC838
Magnetic Gate Lock:
Incredible 1,200 Lb. holding force. Operates
on 12 or 24Vdc. Low power consumption.
Universal mounting holes for ease of
installation. Automatically releases when
power is lost.
50-19509
6" Post Mounting Kit for control box
50-19511
4" Post Mounting Kit for control box
50-19512
2 1/2" Post Mounting Kit for control box
OPEN
370LM
3-Button Mini-Remote Control
with SECURITY✚®:
With key ring and fastening strip.
373LM
3-Button SECURITY✚® Remote
Control:
Includes visor clip.
86LM
Remote Antenna Mounting Kit:
Kit contains antenna bracket and 15' (4.6 m)
of cable. Recommended for increasing the
effective range of transmitters.
50-19503
Push to Open Bracket
25
WIRING DIAGRAM
1. ANTENNA INPUT
2. CLOSE EDGE
3. OPEN EDGE/PHOTO EYE
4. OPEN PHOTO EYE
5. CLOSE PHOTO EYE
6. 24VDC ACCESSORY OUTPUT
7. CONTROL INPUTS/EXIT LOOP
8. LOOP INPUTS, SAFETY/SHADOW
9. TRANSFORMER INPUT/SOLAR INPUT (OPTIONAL)
10. SECOND - OPERATOR ARM CONNECTION
11. 24VDC ACCESSORY OUTPUT
12. MASTER OPERATOR ARM CONNECTION
Flashing Strobe
(optional)
Siren
(optional)
Fault Alarm
ANTENNA
CONNECTION
1
Solenoid Lock
(optional)
P2
R223
P1
14
K6
J1
K5
MAGLOCK
17
NO
J18
OFF
OFF
SINGLE
NO
NO
S8
R2
LEARN
XMITTER
R1
10A 32V
2
GATE 1
B LU
CLOSE
PHOTO
GATE 1
Z12
SET
CLOSE
LIMIT
SET
OPEN
LIMIT
R9ÿ
21
R1ÿ 1
W HT
BRN
R1ÿÿ
GRN
F4
YE L
B LU
FORCE
24
BIPART
DELAY
COM OVLD
OVLD
CONTROL
INPUTS
TIMER TO SINGLE
BUTTON
CLOSE
OPEN (EXIT LOOP)
OPEN
SINGLE BUTTON
RESET
STOP
RESET
MAX
OFF
MAX
OFF
MAX
25
STOP
COMMON (+24VDC)
COMMON (+24VDC)
COM
F5
BLU
COM
D21
RED
C12
D27 Z3
F7
Z4
Q22
7
D9
D8
GATE 2
10
POWER
R35
K3
C13
D22
LOOP
INPUTS
C4
SHADOW
SHADOW LOOP
U3
R196
J4
F6
F2
MOV2
R9
MOV1
YELLOW/GREEN
JMPR1
YELLOW
BLACK
9
BLUE
BATT 2
8
BATT 1
D6
GROUND
NOTE: Yellow/green wire must
be disconnected when earth
ground rod is installed.
FUSE
OPEN
D2
U2
DB1
F1 20A 32V
D4
D1
C64
JMPR2
16
15
RED
24 VAC/
SOLAR
INPUT
BLACK
C2
COMMON (+24VDC)
COM
CHGR
OVLD
RED
R4
INTERRUPT LOOP
INTERRUPT
C11
D15
(OR OPTIONAL EARTH GROUND WIRE)
PHOTO
SWITCHED
ACCESSORY
POWER
SINGLE BUTTON
MIN
OR
24VDC OUTPUT
SWITCHED OFF
IN LOW POWER MODE
6
24V
22
TIMER
RUNNING
23
K4
YEL
RED
PULSING PHOTO
5
PHOTO
20
ACCESSORY
OVLD
10A 32V
WHT
OR
PHOTO
OR
LEARN
LIMITS
GATE 2
24V
GRN
GATE 2
Z8
BLU
BRN
OR
PHOTO
19
DIAGNOSTIC
K1 Q9
EDGE
PULSING PHOTO
R93
ACCESSORY
POWER
11
4
OR
R94
RED
12
Z9
OPEN
PHOTO
OR
EDGE
EDGE
Z22
R92
U4
R91
YEL
RED
SAVE
MAGLOCK
MODE
EDGE
PHOTO
18
K2
WHT
YE L
GATE 1
D1ÿ
GRN
ON
ON
DUAL
NC
NC
EDGE
PULSING PHOTO
OR
R224
S1
F3
BRN
W HT
1 2 3 4 5
1
NC
O
N
C
OR
EDGE
3
OPEN EDGE/
PHOTO
L1
Z1
GRN
EDGE
Z2ÿ
R227
C
Maglock
(optional)
BRN
OR
R2ÿ 7
NO
13
2
CLOSE
EDGE
J19
ALARM
13. MAGLOCK/SOLENOID OUTPUT
14. FAULT ALARM OUTPUT
15. BATTERY INPUT #1
16. BATTERY INPUT #2
17. DIP SWITCH, S1
18. LEARN XMITTER
19. MASTER GATE JOG
20. LIMIT SET
21. SECOND GATE JOG
22. SBC (SINGLE BUTTON CONTROL)
23. FORCE SET
24. BIPART DELAY SET
25. TIMER TO CLOSE SET
NOTE: Batteries must be connected
to operate.
OR
To protect against fire and electrocution:
• DISCONNECT power and battery BEFORE
installing or servicing operator.
• Replace ONLY with fuse of same type and rating.
26
TROUBLESHOOTING
FAULT
POSSIBLE CAUSE
FIX
OPERATOR IS DEAD
When power is supplied to
the control board, no LED
turns ON.
1) Battery fuse is blown.
2) Battery or Run Transformer
connection is loose.
3) Dead battery.
4) Bad control board.
➤ Replace battery fuse. Use only 20A, ATC style fuse.
➤ Check battery and transformer connections.
OPERATOR DOES NOT
RUN
Unit does not respond to a
Radio command.
1) Low battery.
2) Radio (remote) not programmed.
3) STOP button connection loose.
STOP LED is OFF.
4) There is an obstruction blocking
photoelectric eyes in direction
of movement.
5) Safety edge is damaged or on an
obstruction.
6) Interrupt loop is obstructed.
7) Bad control board.
8) Motor fuse is blown.
➤ Measure voltage across battery > 23V.
➤ See Programming Remote section for programming instructions.
➤ Check STOP button connections (STOP and COM) to make sure they
are secure.
➤ Check gate area to ensure photoelectric eyes are not blocked.
➤ Measure voltage across battery > 23V.
➤ Replace control board.
➤ Check gate area to ensure safety edge is not resting on an obstruction.
Check safety edge wiring and connections.
➤ Check gate area to ensure path is unobstructed.
➤ Replace control board.
➤ Replace motor fuse. Use only 15A, ATC style fuse.
OPERATOR DOES NOT
RUN
Unit does not respond to
SBC command.
1) Low battery.
➤ Measure voltage across battery > 23V.
2) SBC button connection loose.
➤ Check SBC and COM connections to ensure they are secure.
3) STOP button connection loose.
➤ Check STOP button connections (STOP and COM) to make sure they
STOP LED is OFF.
are secure.
4) Obstruction is blocking the photoelectric ➤ Check gate area to ensure photoelectric eyes are not blocked.
eyes in the direction of movement.
5) The safety edge is damaged
➤ Check gate area to ensure safety edge is not resting on an obstruction.
or on an obstruction.
Check safety edge wiring and connections.
6) Interrupt loop is obstructed.
➤ Check gate area to ensure path is unobstructed.
7) Bad control board.
➤ Replace control board.
8) Motor fuse is blown.
➤ Replace motor fuse. Use only 15A, ATC style fuse.
MOTOR DOES NOT RUN
Relays ‘click’ when Radio
or SBC signal is given, but
the operator does not
move.
1) Bad motor.
2) Cable wiring between control and
operator arm disconnected or loose.
3) Bad control board.
4) Batteries not connected.
➤ Replace motor.
➤ Replace control board.
GATE STOPS AND
REVERSES RIGHT AFTER
IT STARTS MOVING
1) A fault has occurred.
➤ Check gate for obstructions.
2) Force set too low.
➤ Adjust FORCE setting until gate completes a full open/close cycle
without reversing. The force setting may need to be adjusted in cold
weather, as the gate will not move as freely.
GATE STOPS RUNNING
RIGHT AFTER IT STARTS
MOVING (BATTERY RUN)
1) Battery voltage low or near low
voltage cut-off.
➤ Charge batteries. If problem persists, they may be near the end of their
life. Replace batteries. NOTE: Replace both batteries at the same time.
Use only Chamberlain part #K74-30762 for replacement batteries.
2) A fault has occurred.
➤ Check gate for obstructions.
1) An input is continuously activated.
➤ Verify that all inputs are functioning properly.
GATE OPENS BUT DOES
NOT CLOSE
➤ Replace control board.
➤ Connect batteries.
2) Entry system output is connected to
➤ Verify Entry system connections and operation.
the Open input, and is “stuck” opening.
27
TROUBLESHOOTING
FAULT
GATE RUNS TOO SLOW
GATE DOES NOT CLOSE
AUTOMATICALLY
POSSIBLE CAUSE
FIX
1) Open and Close Limits are set too
close together.
➤ If the Open and Close Limits are set within the ramp down distance of
each other, the gate will run at slow speed all the time.
2) The gate is starting within the ramp
down distance from the Open or
Close Limit.
➤ Gate will run slow to limits if motion is started within the ramp-down
distance from the limit.
1) Verify that the Timer-to-Close is
➤ Verify that the Timer-to-Close is ON and set.
turned OFF.
2) Gate opened by an obstruction reversal. ➤ Check gate area to ensure path is unobstructed.
3) The Interrupt Loop is obstructed.
4) Obstructed close photoelectric eye or edge.
➤ Check the Open Loop area to ensure all obstructions are removed. If an
5) The Open input is “stuck”.
external opening device or entry or entry system is attached, check for
proper operation of that system.
GATE WON’T STAY OPEN
WHEN USING FIRE INPUT
Fire Input switch should be
a constant contact key
switch connected to Open
Loop input
(Open only).
1) Fire Input switch is a momentary
contact.
➤ Make sure the Fire Input switch is constant contact. If it is not, replace
with a constant contact switch.
INTERRUPT LOOP DOES
NOT ACT PROPERLY
1) Bad loop sensor or loop detector.
➤ Replace loop sensor or loop detector.
2) Bad connection between loop sensor,
loop detector, and the control board.
➤ Check connections to make sure they are secure.
1) Bad loop sensor or detector.
2) Bad connection between the loop
sensor, loop detector, and the
control board.
3) The Shadow Loop is obstructed.
4) An Open photoelectric eye or safety
edge is obstructed.
➤ Replace loop sensor or loop detector.
➤ Check connections to make sure they are secure.
1) Bad connection between the Maglock,
its power supply, and the control board.
2) Bad Maglock or Maglock power supply.
3) Large gap between gates.
4) Bad control board.
➤ Check connections between the Maglock, its power supply, and
the control board to make sure they are secure.
➤ Replace Maglock or Maglock power supply.
➤ Reduce the gap between the gates.
➤ Replace the control board.
EXIT LOOP (FREE EXIT)
DOES NOT OPEN GATE
MAGLOCK DOES NOT
WORK
Maglock does not hold
gates locked
➤ Check the gate area to make sure all obstructions are removed.
➤ Check the gate area to make sure all obstructions are removed.
DIAGNOSTIC CODES
# OF BLINKS
1
2
3
4
5
6
7
8
9
10
MEANING
No Stop Switch Connected
Gate 1 Arm Disengaged
Gate 2 Arm Disengaged
Both Gate Arms Disengaged
RPM Reversal
Force Reversal
Processor Reset
ROM Check Failed
RAM Check Failed
EEPROM Check Failed
28
REPAIR PARTS
Refer to the parts lists below for replacement parts available for your operator. If optional modifications and/or accessories are included
with your operator, certain components may be added or removed from these lists.
CONTROL BOX LA400-CONT
ITEM
1
2
3
4
5
6
7
8
Not Shown
PART #
K001A6039
K75-15480
DESCRIPTION
Control Board
Control Box & Cover
with Gasket
Control Board Bracket
Reset Switch
Antenna
Battery
Transformer
Alarm
ATC Fuse Kit Includes
20 Amp (1), 15 Amp (2)
K75-30764
K23-19380
K74-19499
K74-30762
K74-30763
K76-19446
K74-30941
8
2
7
3
4
6
1
5
29
QTY
1
1
1
1
1
2
1
1
REPAIR PARTS
ACTUATOR ARM KITS
ITEM
1
2
3
4
Not Shown
PART #
DESCRIPTION
41ASWG-442SA
41ASWG-438SA
41ASWG-0014SA
41ASWG-489
41ASWG-0119
Release Lever
Motor with Limit Switch Harness
Rear Connector
Cable 24V with Connector
Release Key
2
1
3
4
30
QTY
1
1
1
1
1
O P E R AT O R N O T E S
31
WARRANTY POLICY AND SERVICE
LIFTMASTER® TWO YEAR LIMITED WARRANTY
The Chamberlain Group, Inc. warrants to the first retail purchaser of this product, for the structure in which this product is originally
installed, that it is free from defect in materials and/or workmanship for a period of two years from the date of purchase. The proper
operation of this product is dependent on your compliance with the instructions regarding installation, operation, maintenance and
testing. Failure to comply strictly with those instructions will void this limited warranty in its entirety.
If, during the limited warranty period, this product appears to contain a defect covered by this limited warranty, call 1-800-528-2806,
toll free, before dismantling this product. Then send this product, pre-paid and insured, to our service center for warranty repair. You
will be advised of shipping instructions when you call. Please include a brief description of the problem and a dated proof-of-purchase
receipt with any product returned for warranty repair. Products returned to Seller for warranty repair, which upon receipt by Seller are
confirmed to be defective and covered by this limited warranty, will be repaired or replaced (at Seller’s sole option) at no cost to you
and returned pre-paid. Defective parts will be repaired or replaced with new or factory-rebuilt parts at Seller’s sole option.
ALL IMPLIED WARRANTIES FOR THE PRODUCT, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE TWO YEAR LIMITED
WARRANTY PERIOD SET FORTH ABOVE, AND NO IMPLIED WARRANTIES WILL EXIST OR APPLY AFTER SUCH PERIOD. Some
States do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. THIS LIMITED
WARRANTY DOES NOT COVER NON-DEFECT DAMAGE, DAMAGE CAUSED BY IMPROPER INSTALLATION, OPERATION OR CARE
(INCLUDING, BUT NOT LIMITED TO ABUSE, MISUSE, FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE,
UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO THIS PRODUCT), LABOR CHARGES FOR REINSTALLING A REPAIRED OR
REPLACED UNIT, OR REPLACEMENT OF BATTERIES.
THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH, OR RELATING TO, THE GARAGE DOOR OR GARAGE DOOR
HARDWARE, INCLUDING BUT NOT LIMITED TO THE DOOR SPRINGS, DOOR ROLLERS, DOOR ALIGNMENT OR HINGES. THIS
LIMITED WARRANTY ALSO DOES NOT COVER ANY PROBLEMS CAUSED BY INTERFERENCE. ANY SERVICE CALL THAT
DETERMINES THE PROBLEM HAS BEEN CAUSED BY ANY OF THESE ITEMS COULD RESULT IN A FEE TO YOU.
UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES ARISING IN
CONNECTION WITH USE, OR INABILITY TO USE, THIS PRODUCT. IN NO EVENT SHALL SELLER’S LIABILITY FOR BREACH OF
WARRANTY, BREACH OF CONTRACT, NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE PRODUCT COVERED HEREBY.
NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS PRODUCT.
Some states do not allow the exclusion or limitation of consequential, incidental or special damages, so the above limitation or
exclusion may not apply to you. This limited warranty gives you specific legal rights, and you may also have other rights which vary
from state to state.
HOW TO ORDER REPAIR PARTS
OUR LARGE SERVICE ORGANIZATION
SPANS AMERICA
FOR INSTALLATION AND SERVICE INFORMATION,
CALL OUR TOLL FREE NUMBER
1-800-528-2806
www.liftmaster.com
WHEN ORDERING REPAIR PARTS
PLEASE SUPPLY THE FOLLOWING INFORMATION:
PART NUMBER DESCRIPTION MODEL NUMBER
ADDRESS ORDER TO:
THE CHAMBERLAIN GROUP, INC.
Technical Support Group
6020 S. Country Club Road
Tucson, AZ 85706
01-19244D
©2007, The Chamberlain Group, Inc.
All Rights Reserved

advertisement

Key Features

  • Medium duty swing gate operator
  • 24Vdc motor
  • Maximum gate width: 16 ft
  • Maximum gate weight: 550 lbs
  • Can operate for up to 4 minutes
  • Travel time: 14-18 seconds for 90 degree opening

Frequently Answers and Questions

What is the maximum gate width and weight that the LA400 can handle?
The LA400 can handle a maximum gate width of 16 ft (4.9 m) and a maximum gate weight of 550 lbs (249.5 kg).
How long does it take the LA400 to open a gate?
The LA400 has a travel time of 14-18 seconds for a 90 degree opening.
Can the LA400 be used in residential, commercial, and industrial applications?
Yes, the LA400 can be used in all three types of applications. The operator is UL325 compliant and meets the entrapment protection requirements for each class.

Related manuals

Download PDF

advertisement