EcoSmart POU 3.5 3.5 kW 0.5 GPM Point-of-Use Electric Tankless Water Heater Troubleshooting guide

Add to My manuals

EcoSmart ECO-6 is a 6-kilowatt tankless water heater that provides a continuous flow of hot water for your home. With its compact size and sleek design, it can be easily installed in tight spaces, making it ideal for small apartments, condos, or homes with limited space. The ECO-6 features advanced safety systems, such as overheat protection and freeze protection, to ensure safe operation. It also comes with a user-friendly digital display for easy temperature adjustment and monitoring.

advertisement

EcoSmart POU 3.5 3.5 kW 0.5 GPM Point-of-Use Electric Tankless Water Heater Troubleshooting guide | Manualzz

ECOSMART TROUBLE SHOOTING GUIDE

MODELS ECO POU 3.5 - 6

THIS STEP BY STEP TROUBLE SHOOTING GUIDE IS DESIGNED FOR

THE INSTALLER IF ANY ISSUES ARISE WITH TANKLESS WATER

HEATER.

Step by Step Trouble Shooting Guide

This Guide is for Use by Qualified Electrical Professional

This Trouble Shooting Guide will take you through simple steps to determine any problems or issues with unit. This Guide takes you through a sequence of steps that MUST be followed. Skipping around might not determine the exact problem, therefore you MUST follow the sequence.

All Ecosmart units have a simple design and are very easy to check with the use of a MULTI CLAMP METER able to measure both Voltage and Amperage.

Below is a picture of an open view of an ECO POU 3.5-6

ECOSMART TANKLESS WATER HEATER.

Follow the steps as described and write down the readings /results on the back pages so when contacting Technical Support you have the information in hand.

ECO POU 3.5@110V

ECO POU 6.0@208V

You can contact our Technical Support at 877-474-6473 Mon-Fri 8:00 am—5:00 pm. EST

DISCONNECT ALL POWER TO UNIT BEFORE REMOVING

COVER.

ELECTRICAL CONNECTION

POU ARE SUPPLIED WITH A 2 PRONE TERMINAL BLOCK AND ATTACHED

CABLES.

SUPPLIED CABLES MUST BE CONNECTED TO AN INDEPENDENT SINGLE OR

DOUBLE POLE BREAKER DEPENDING ON THE MODEL.

IN ORDER TO MAKE SURE THE WIRING IS CONNECTED CORRECTLY

PERFORM THE FOLLOWING TEST.

ONCE THE CABLES HAVE BEEN SECURELY ATTACHED TO BREAKER TURN

POWER ON TO UNIT. MEASURE THE VOLTAGE GOING TO TERMINAL

BLOCK.

IF POWER GOING TO THE UNIT IS NOT CORRECT, THE UNIT WILL NOT

OPERATE CORRECTLY, SO IT IS IMPORTANT TO PERFORM THIS TEST

FIRST, BEFORE PROCEEDING .

IF NO VOLTAGE THE PROBLEM IS NOT AT THE UNIT, BUT AT YOUR ELEC-

TRICAL PANEL , OR BREAKERS.

NOW THAT WE HAVE VERIFIED THAT THE ELECTRICAL CONNECTIONS ARE

CORRECT, LETS CONTINUE.

VERIFYING SAFETY THERMOSTATS

THE FOLLOWING STEP WILL VERIFY POWER IS GOING THROUGH THE

SAFETY THERMOSTATS.

IF THE THERMOSTAT IS DAMAGED THE HEATING ELEMENT WILL NOT

FUNCTION OR HEAT UP.

TO VERIFY THE THERMOSTAT YOU NEED TO HAVE THE BREAKER TURNED

ON. YOU WILL PERFORM THIS TEST WITH YOUR VOLT METER.

THIS TEST WILL VERIFY THAT ELECTRICAL POWER IS GOING TO THE BOTTOM AND ACROSS THE THER-

MOSTAT.

USING YOUR VOLT METER YOU NEED TO PLACE ONE PROBE AT THE BOTTOM METAL PART OF THE THER-

MOSTAT AND THE OTHER PROBE NEEDS TO BE GROUNDED.

THEN PERFORM THE SAME TEST ON THE TOP PART OF THE THERMOSTAT.

ALL READING ON THIS TEST SHOULD BE IN THE 110-115V RANGE.

AGAIN, YOU MEASURE CURRENT GOING INTO BOTTOM OF THERMOSTAT TO GROUND AND THEN THE TOP

PART OF THERMOSTAT TO GROUND TO ENSURE THE THERMOSTAT IS IN GOOD WORKING CONDITION.

VERIFYING HEATING ELEMENTS

THE FOLLOWING STEP WILL VERIFY THE HEATING ELEMENTS ARE WORKING CORRECTLY.

THE HEATING ELEMENTS WILL ONLY DRAW VOLTAGE WHEN HOT WATER IS

BEING USED . WHEN HOT WATER IS DEMANDED THE ELEMENTS WILL IN-

STANTLY DRAW VOLTAGE.

THERE ARE TWO RED WIRES CONNECTED TO THE TOP OF THE ELEMENT. IN

ORDER TO CHECK IF THE ELEMENT IS WORKING YOU MUST TURN ON A HOT

WATER TAP. THIS WAY THE ELEMENTS WILL DRAW VOLTAGE AND CAN BE

CHECKED.

ONCE YOU HAVE WATER RUNNING THROUGH THE UNIT THE LED DISPLAY

WILL LIGHT UP AND DISPLAY THE TEMPERATURE SETTING ON THE UNIT.

USING YOUR VOLT METER-PLACE ONE PROBE ON ONE SCREW AND THE

OTHER PROBE ON THE OTHER SCREW LOCATED ON THE TOP OF THE ELE-

MENT. CHECK WHAT VOLTAGE YOU ARE DRAWING.

WHEN MEASURING VOLTAGE ACROSSS THE TOP OF THE ELEMENTS YOU

WILL GET A VOLTAGE READING.

REMEMBER– YOU MUST HAVE WATER RUNNING IN ORDER FOR THE ELEMENTS TO ACTIVATE AND DRAW

POWER.

IF YOUR LED DISPLAY IS LID AND YOU HAVE WATER RUNNING THROUGH THE UNIT AND HAVE 0 VOLT-

AGE READING WHEN MEASURING WITH PROBES ON EACH SCREW -PERFORM THE SAME TEST, BUT THIS

TIME PLACING ONE PROBE ON ONE SCREW AND THE OTHER PROBE TO GROUND. DO THE SAME ON THE

OTHER SCREW. IF YOU ARE GETTING VOLTAGE READINGS WHEN TESTING ON ONE SCREW TO GROUND

BUT NO VOLTAGE WHEN MEASURING FROM SCREW TO SCREW YOUR ELEMENT MIGHT BE BAD AND MUST

BE REPLACED.

You can contact our Technical Support at 877-474-6473 Mon-Fri 8:00 am—5:00 pm. EST

AMPERAGE DRAW

THIS TEST IS TO MEASURE AMPERAGE DRAW ON ELEMENT. THIS IS

DONE BY USING THE CLAMP PORTION OF THE METER AND CLAMPING

AROUND THE RED WIRE THAT GOES TO HEATING ELEMENT.

WHILE WATER IS RUNNING GET THE AMPERAGE DRAW FOR ELEMENT.

IT IS IMPORTANT TO FOLLOW THESE STEPS AND WRITE DOWN THE

READINGS/RESULTS.

THESE STEPS WILL ASSIST IN A QUICK RESOLUTION TO ANY ISSUES

YOU MIGHT HAVE WHEN CONTACTING OUR TECHNICAL SUPPORT

DEPARTMENT.

THE LAST PAGE IS DESIGNED TO DOCUMENT ALL READINGS

SHOULD YOU HAVE ANY QUESTIONS BEFORE , DURING OR AFTER IN-

STALLATION YOU CAN CONTACT OUR TECHNICAL SUPPORT DEPARTMENT

TOLL FREE AT 877-474-6473

Email: [email protected]

Or visit our web site at www.ecosmartus.com

VOLTAGE AT TERMINAL BLOCK L1________ L1________

VOLTAGE AT THERMOSTATS

TOP__________

BOTTOM__________

VOLTAGE AND AMPERAGE AT HEATING ELEMENTS

SCREW/SCREW___________

AMPS ___________