Krendl 5200-P Owner's Manual
Advertisement
Advertisement
Fiber Moving Equipment
OWNERS MANUAL
MODEL #5200-P
50 YEARS OF QUALITY AND SERVICE
KRENDL MACHINE COMPANY • 1201 SPENCERVILLE AVE
DELPHOS, OHIO 45833 • TELEPHONE 419-692-3060 • FAX 419-695-9301
E - MAIL: [email protected] • WEB SITE: www.krendlmachine.com
MODEL #5200-P
CONGRATULATIONS ON YOUR PURCHASE OF KRENDL EQUIPMENT
THIS IS YOUR
MODEL #5200-P OWNER'S MANUAL
FOR ASSURED SAFETY AND CONFIDENCE, PLEASE READ THIS
MANUAL CAREFULLY BEFORE INSTALLING AND OPERATING YOUR
MACHINE.
KRENDL E-MAIL ADDRESS IS: [email protected]
KRENDL WEB SITE IS: www.krendlmachine.com
MODEL #5200-P
Table of Contents
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
UNPACKING & INSPECTING EQUIPMENT . . . . . . . . . . . . 2
GENERAL SAFETY INFORMATION . . . . . . . . . . . . . . . . . 2-5
DECALS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7
WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
RETURNED GOODS PROCEDURE . . . . . . . . . . . . . . . . . . 9
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
BASIC COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-13
OPERATING INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . 14-17
GENERAL MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . 18-21
ELECTRICAL SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . 23-24
SPARE PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25-31
GLOSSARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
SERVICE RECORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
MODEL #5200-P
INTRODUCTION
Thank you for purchasing a KRENDL FIBER MOVING MACHINE. With over fifty years experience in manufacturing fiber moving equipment, we have designed and built your machine with the highest quality parts and workmanship to provide years of reliable service.
This manual has been prepared to help you obtain the maximum efficiency and service from your
Krendl equipment. This machine is designed to blow cellulose, fiberglass and rockwool into attics. Our primary objective is to build equipment which will provide complete satisfaction so that you may confidently recommend Krendl to others.
We do not manufacture or sell fiber. Our interest lies only in the proper performance of the equipment we manufacture. The fiber material manufacturer’s instructions prevail when it comes to applying their product, since they guarantee the final results.
This manual contains important information regarding the safe assembly and operation of your machine. We urge you to read it carefully and THOROUGHLY before putting your machine to work. If your questions are not answered in this manual, please contact us. We want you to be able to operate this equipment safely and confidently.
Upon receipt of this machine, check it carefully for any shipping damage. If there is damage or if any of the parts are missing, notify the delivery trucking company immediately and file a claim for damages, saving all packaging materials for inspection. Our warranty covers manufacturer’s defects only. If Krendl Machine Company delivered or set up your machine and any parts are missing or damaged, notify the authorized representative before they leave.
Krendl Machine Company
1201 Spencerville Avenue
Delphos, Ohio 45833 U.S.A.
Telephone: 419-692-3060
Fax:
E-Mail:
Web Site:
419-695-9301 [email protected]
www.krendlmachine.com
For your protection in the event of theft or loss, please fill in the information requested for your own records. This information will be needed for in-warranty repairs. You may also want to attach a copy of your invoice.
Machine Model No. __________________________________________________________________
Machine Serial No. __________________________________________________________________
Engine Manufacturer ________________________________________________________________
Engine Model No. , Serial No. _________________________________________________________
Blower Manufacturer ________________________________________________________________
Blower Model No., Serial No. __________________________________________________________
Blower Clutch Manufacturer __________________________________________________________
Blower Clutch Model No., Serial No. ____________________________________________________
Airlock Clutch Manufacturer ___________________________________________________________
Airlock Clutch Model No., Serial No. _____________________________________________________
Rev. Date: 12/14/10 Page 1
MODEL #5200-P
UNPACKING AND INSPECTING EQUIPMENT
RECEIVING YOUR MODEL #5200-P KRENDL MACHINE:
Immediately check the condition of your Model #5200-P machine when it is received. It should be received in the same condition that it was shipped to you. If there are any visible prob- lems with your machine or any other items in the shipment, it is imperative that you place any
claim with the delivery carrier. Please save all packaging materials for inspection. The delivery carrier should also contact our office before leaving the premises to notify us of a claim. The ownership to your machine and all other items in the shipment were transferred to your name as soon as the shipment left our premises, thus it is your responsibility to contact us with any claims. Contact the truck line to arrange for an independent inspector to come out to inspect the damage and to prepare the inspection report. It is imperative that this inspection is done prior to unpacking or using any of the equipment. Please contact us for assistance or with any questions you may have regarding the claim process.
UNPACKING:
Handle all cartons with care to avoid damage from dropping or bumping. Completely remove machine from the packaging and from any shipping pallet or skid to which it might be attached. In addition, completely remove all shipping materials from inside the machine. Check that all parts are included as stated on the list below.
ACCESSORIES INCLUDED:
• 150’ REMOTE CONTROL CORD
• MULTIMETER
• SPANNER WRENCH FOR BELT TENSIONERS
• #50 CHAIN MASTER LINK
• SECTION OF CHAIN FOR CHANGING SHREDDER DIRECTION
• 5/16 ALLEN WRENCH FOR ADJUSTMENT OF CHAIN IDLERS
• OWNERS MANUAL
GENERAL SAFETY INFORMATION
Important: Read all instructions before operating this equipment. This equipment can be potentially dangerous and must be used in strict accordance with instructions.
Disclaimer Notice: The manufacturer will not be legally responsible for any injury or damage resulting from the improper use of this equipment or the failure to follow instructions.
Unpacking
Handle cartons with care to avoid damage from dropping or bumping. Completely remove the machine from the packaging and from any shipping pallet or skid to which it may be attached. In addition, completely remove all shipping materials from the inside of the machine.
Important: Please recheck inside the hopper for any loose items or damaged equipment.
Injury may occur when equipment is started with foreign material in the hopper.
Rev. Date: 12/14/10 Page 2
MODEL #5200-P
General Safety
1.
Read this manual carefully and become familiar with your machine. It is important to know it’s applications, limitations, and any hazards involved prior to operating the machine.
2.
This machine was designed and manufactured for blowing cellulose, fiberglass and rockwool. Do not attempt to modify the unit or use it for any application it was not designed for. If you have any questions about your intended use or the machine’s suitability, ask your dealer/distributor or consult the factory. The manufacturers could not possibly anticipate every circumstance that might involve a hazard. For that reason, warnings in the manual and warning tags or decals affixed to the unit, are not all-inclusive. If you intend to handle, operate, or service the unit by a procedure or a method not specifically recommended by the manufacturer, first make sure that such a procedure or method will not render this equipment unsafe or pose a threat to you and others.
3.
Do not disable any of the safety features on the equipment. These features are for your protection and safety.
4.
Read and obey all safety and operating instructions in the manual and on the machine.
5.
Equipment is to be operated and/or maintenanced by TRAINED & QUALIFIED personnel ONLY!!
6.
BEFORE PERFORMING ANY MAINTENANCE ON THE MACHINE, YOU MUST FIRST:
#1 TURN THE DISCONNECT SWITCH TO THE “OFF” POSITION
#2 DISENGAGE PTO AND TURN THE TRUCK OFF
#3 TURN THE IGNITION TO THE “OFF” POSITION AND REMOVE KEY
7.
Do not operate the machine without all guards and safety equipment installed in the proper location and in working order. Always follow the proper shut down procedures outlined in Item 6 when guards are removed from the machine or when compartment or electrical control doors need to be opened.
8.
If a malfunction occurs while running the machine, turn it off immediately, follow the directions under item 6 and correct the problem prior to restarting the machine.
9.
Keep body and all clothing away from rotating equipment. Rotating shafts can be dangerous.
10. Always wear proper safety equipment when operating the machine. This includes steel toed shoes, safety glasses and a respirator.
11. Under no circumstances should your hand, a stick or a broom be used to force material down into the hopper. The machine is a self feeding design and requires no outside assistance.
12. Stand on the floor, not a platform while operating the machine. The operator may lose balance and fall while loading bags of material.
All Model #5200 Machines are factory equipped with side, front, and main drive belt guards. The top of the machine is not guarded since it poses no safety threat for normal insulation blowing operations when mounted as shown in the installation guide. The machine is designed to be mounted in the van body of the contractor’s truck and the rear of the machine against the wall of the van body.
Always turn the main power switch (located on the electrical box) to off and unplug the remote cord from the receptacle for any type of machine maintenance or adjustments. An additional safety feature is the ability to adjust the material slide gate from the outside of the machine. Rotate the adjustment handle clockwise to open the slide to the desired setting, no entrance into the machine is required.
All safety features are incorporated into the machine to protect everyone from serious injury. Operate your machine according to the outlined instructions in the manual with all guards in place and securely latched. Operation with any guards removed can result in injury to or loss of fingers, hands, arms, toes, feet, legs, hair, and even your eyes.
Rev. Date: 12/14/10 Page 3
MODEL #5200-P
Electrical Safety
• The National Electric Code (NEC) in the United States and many international electrical codes require frame and external electrically conductive parts of this machine to be properly connected to an approved earth ground. Local electrical codes may also require proper grounding of machine. Consult with local electricians for grounding requirements in your area.
• Never handle any kind of electrical cord or device while standing in water, while barefoot or while hands or feet are wet. Dangerous electrical shock will result.
• Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area. (metal decking or steel work)
• Reference NFPA 79, 70E, or OSHA safe work practices when preforming energized work procedures.
Safety/Caution
• Be Safe - Keep away from moving parts.
• Be Safe - Make sure all guards and hopper extensions are in proper place before operating machine.
Guards and safety devices/switches should not be removed, modified or by-passed.
Hands should never pass between rotating parts.
• Be Safe - Make sure remote control hand pendant switch is in off position before connecting the power supply to the machine.
• Be Safe - Make sure machine is properly grounded. Protect all electrical supply cords from sharp objects, moisture, and other potentially hazardous materials. Keep power cords in good repair. Electrical service must be performed by a qualified electrician.
• Be Safe - Disconnect power supply before inspecting or adjusting unit.
• Be Safe - Consult a qualified technician to answer questions before attempting to operate, or injury may result.
• Be Safe - Emergency Kill Switch - In case of emergencies, always use red stop button located on the front of Main Control Panel and on the side of the hopper. It will stop all feeding and agitation.
• Be Safe - Do not remove motors or lift hopper when unit is connected to power supply.
• Be Safe - Do not operate machine alone.
• Be Safe - Do not leave machine unattended and energized.
• Be Safe - Turn machine off and disconnect electricity before clearing and feeding jam or attempting to remove any object dropped in the hopper.
• Be Safe - Keep hands, loose clothing, jewelry and hair away from agitators, gears, chains and other moving parts.
• Be Safe - Use proper lifting when moving fibers and loading machine.
• Be Safe - Keep work area clear of debris.
• Be Safe - Wear proper safety equipment, including protective gear, such as respirators, eye and ear protection.
• Be Safe - Violation of the Owner's Manual or safety precautions may void warranty.
Rev. Date: 12/14/10 Page 4
MODEL #5200-P
Make Sure!
• Hopper is empty of foreign objects before starting.
• Adequate electrical power is supplied or damage to unit will result.
• Machine must be on before adding fiber.
• Blower filter is kept clean and in place when blower is on.
• Machine is turned off immediately if hose is plugged, or blower will overheat.
• Blower must be on, when agitators are running, or machine will bind.
• Agitator motor is not run with hopper empty for more than a few minutes, or damage to seals will result.
• Sprockets, chains, belts and pulleys are correctly aligned and tensioned.
• Pieces of bag are not left in the machine as this can bind and stall your machine.
• This machine should only be used with good quality fibers that are dry, undamaged and that meet a certain industry specification or quality standards.
IF THERE ARE ANY QUESTIONS WITH YOUR KRENDL MACHINE, DO NOT HESITATE TO
CONTACT US AT: 1-800-459-2069
DECALS
Indicates that the electrical box on the machine is in compliance with UL codes.
General safety information intended to reduce the risk of serious injury or death
Indicates which employee inspected equipment and on what date.
Electrical maintenance information and schedule provided here.
Rev. Date: 12/14/10
Indicates if blower is off, on, or on with agitator.
Page 5
MODEL #5200-P
Keeping the filter clean will result in longer blower life and better performances.
Rotating parts can be dangerous! You can snag clothes, skin, hair, hands, etc. This can cause serious injury or death.
Manufacturer information is provided here along with machine model, and serial number.
Opens and closes the material feed gate which in turn controls the production.
Emergency stop button for machine.
Made in the U.S.A.
Read manual before operating machine for assured safety.
Take caution when handling electrical cords or electrical shock or death may result.
Machine should be used with these products.
Rev. Date: 12/14/10
Identifies position of material feed gate.
Page 6
Operating machine at specified voltage will result in longer machine life and better performance.
MODEL #5200-P
KMC-01234
Part number for identification and tracking.
Rotating parts will be moving in this direction.
Indicates that this outlet is intended for only the remote control outlet. Each time machine cycle starts, an audible alarm warns the operator that the machine is about to come on.
Identifies if machine is in remote mode, manual mode, or off position. In manual mode this switch operates machine. In remote mode the hand pendant operates machine. Each time machine cycle starts, an audible alarm warns the operator that the machine is about to come on.
Indicates that this outlet is intended for only the wireless remote. Each time machine cycle starts, an audible alarm warns the operator that the machine is about to come on.
Indicates if the latches on the access door are locked or unlocked
Keeping the door closed will keep bystanders safe from rotating parts.
Rev. Date: 12/14/10 Page 7
MODEL #5200-P
WARRANTY:
Krendl Machine Company (Company) warrants to each original purchaser (Buyer) of its equipment or accessories that such products will be free of manufacturing defects for a period of 12 months from the date of shipment to the Buyer.
No warranty is made with respect to:
1. Components or accessories manufactured and warranted by others. Warranties for purchased component parts as supplied from vendor such as engine, electric motor, blower, gearbox, transmission, etc., if furnished by the manufacturer of the component, are on file at the Company’s main office and copies will be furnished at request of Buyer.
Component(s), shipping costs prepaid, shall be sent to Company who in turn shall forward to vendor for evaluation and warranty determination.
2. Any defect caused by repair, alteration and/or adjustment performed by Buyer or customer/vendor of Buyer without the express written authorization of the Company.
3. The labor costs of replacing parts by parties other than the Company.
4. Any machine that has not been operated and/or maintained in accordance with normal industry practice and the written recommendations of the Company. (e.g. machine operated with an improperly sized, worn or damaged hose, improper or inattention to preventative maintenance, etc.)
5. The product has been subjected to misuse, negligence or accident or results of any application or use of the blowing equipment not in accordance with the Company recommendations.
This limited warranty does not cover the free replacement of component parts that become inoperative due to wear and usage and need to be replaced on a regular basis, including but not limited to: airlock seal(s), agitator(s), shredder(s), auger(s), fuse(s), switch(es), clutch(es), hose(s), shaft seal(s), chain(s), belt(s), sprocket(s), pulley(s), bearing(s), cable(s), battery(ies), filter(s), fan(s), etc.
The Company’s obligation under this warranty is limited to repairing or replacing (at Company option) any part that is determined by the Company to be suffering from a manufacturing defect.
The Company (at Company option) will provide any required parts and labor to the Buyer. If the equipment or parts must be returned to the Company for repair, all transportation costs shall be the Buyer’s responsibility.
THIS LIMITED WARRANTY IS EXPRESSLY IN LIEU OF ANY OTHER GUARANTEES AND / OR
WARRANTIES, ORAL OR WRITTEN, EXPRESSED OR IMPLIED, INCLUDING WITHOUT LIMITA-
TION, THE IMPLIED WARRANTY OF MERCHANTABILITY. NO WARRANTY, EXPRESS OR
IMPLIED, OTHER THAN THE AFORESAID WARRANTY IS MADE OR AUTHORIZED BY COM-
PANY. COMPANY SHALL NOT BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES TO PROPERTY OR INJURY TO ANY PERSON OR COSTS
ASSOCIATED WITH LOSS OF PRODUCTION RESULTING IN LOSS OF REVENUE, PROFITS
OR LOSS OF EQUIPMENT THROUGH THE USE OF THIS EQUIPMENT.
Note: Special job circumstances incurring costs for specialized repair and next day delivery of parts will not be reimbursed by the manufacturer unless authorized by factory.
Rev. Date: 12/14/10 Page 8
MODEL #5200-P
RETURNED GOODS PROCEDURE
IF MACHINE WAS NOT PURCHASED DIRECTLY FROM KRENDL MACHINE COMPANY, CON-
TACT YOUR SUPPLIER / DISTRIBUTOR.
When returning products to Krendl for repair, first obtain a return goods authorization (RGA), at which time you will be given shipping instructions. The product must be shipped PREPAID:
Krendl Machine Company
1201 Spencerville Ave.
Delphos, Ohio 45833 U.S.A.
Telephone: 419-692-3060
Fax: 419-695-9301
E-mail:[email protected]
Web Site: www.krendlmachine.com
Once the unit is received, it will be inspected. In-warranty units will be repaired and returned immediately. An estimate of repair charges will be provided for out-of-warranty units.
SPECIFICATIONS
MODELS:
MACHINE:
#5200-P
14” Diameter x 18” Length airlock feeder electromagnetic clutches on agitator and blower in line helical gearbox (driving the machine)
HEIGHT:
LOAD HEIGHT:
WIDTH (DEPTH):
LENGTH:
WEIGHT:
ELECTRICAL:
BLOWER VOLUME:
BLOWER PRESSURE:
HOSE OUTPUT:
MAXIMUM FEED RATES:
CELLULOSE: 5200 lbs./hr.
83.00 inches
59.00 inches
43.00 inches
80.00 inches
2000 pounds
12VDC remote control system (6000 watt generator supplying
120VAC to convenience outlets & accessories)
250 CFM
6.0 PSI maximum
4” diameter
FIBERGLASS: 2300 lbs./hr.
WARNING:Recommended hose size, type and length must be used to achieve maximum results. Krendl cannot guarantee performance of the #5200-P machine if hoses are undersized, worn, damaged, or hoses other than those we recommend are used.
BEFORE YOU RUN THIS MACHINE...PLEASE READ THE REST OF THIS MANUAL!!
Rev. Date: 12/14/10 Page 9
MODEL #5200-P
BASIC COMPONENTS
This is a view of the basic components of your Model #5200-P machine. It shows the location of each item and gives the function of each. Use this as a guide throughout the manual.
(Illustration 1)
A) Base Unit - Lower frame unit supporting blower box, speed reducer, motor, airlock and hopper.
B) Airlock - Traps air and fiber while providing a metered flow.
C) Shredder System - Increases production and coverage on all fiber products while reducing clumps that may exist in various fibers.
D) Slidegate - Meters the amount of fiber dropping into the airlock by controlling size of airlock opening.
E) Speed Reducer - Increases output power while decreasing speed of agitator/airlock drive motor.
F) Agitator - Conditions fiber in the hopper.
G) Hopper - Upper unit of machine holding fiber.
(Illustration 2)
H) Main Control Panel - Connects with main power, allowing operation of unit at machine or
Remote Cord.
I) Kill Switch - Safety device for immediate stopping of machine.
J) Blower - Provides the air necessary to move fiber from the airlock.
K) Hydraulic Motor - Provides driving power for speed reducer, blower, generator, and agitator/ airlock system.
L) Generator - Provides power to all auxiliary electrical components.
M) Hopper Extension - Increases overall hopper capacity.
Illustration 2
Illustration 1
Rev. Date: 12/14/10 Page 10
MODEL #5200-P
INSTALLATION
MACHINE DRIVE AND TRUCK SPECIFICATIONS:
Your Model #5200-P Krendl Machine can be mounted in any truck and chassis configuration. We recommend a minimum chassis rating of 26,000 GVWR. We also recommend a minimum 22 feet van body. The body should have a full width rear door. The Krendl Model #5200-P Machine can be mounted anywhere in the truck body. The factory recommended positions are shown in Illustration 3.
TOOLS NEEDED:
1/2” Heavy Duty Drill
Drill Bits: 9/16” for bolts
Fork Lift (means to lift the machine)
Pry Bars
Basic Wrenches
5” hole saw & 2” hole saw
CUSTOMER SUPPLIED ITEMS:
1/2” Bolts, washers, locknuts for fastening machine
INSTALLATION INSTRUCTIONS:
1) Place the machine in either of the two locations so that the machine will not be in the way of the truck’s doors and you are still able to open the hood of the machine.
2) Using illustration 3 as a reference, check under the truck body that the opening will not interfere with any truck components underneath. If there is any interference with any of the truck parts, then you will need to adjust the position of the machine to clear the obstruction. The holes for the blower inlet and machine hold down do not have much room for adjustment. However, the holes for the hydraulic lines do have room for slight adjustments.
Illustration 3
3) Remove the machine after the holes are located.
Rev. Date: 12/14/10 Page 11
4) Cut the following holes: (Using illustration 4 as reference ONLY) a. Blower Inlet: 5” b. Hydraulic Lines: 2”I
MODEL #5200-P
B
A
B
A
Illustration 4
5) Place the machine in the truck lining it up with the holes.
6) Locate and drill 9/16” holes for the four hold down holes located in the bottom of the base flange.
Again, check the underside of the truck body for any obstructions. Use 1/2” bolts and nuts to bolt the base to the truck floor.
7) Run hydraulic lines to the machine.
8) Attach hydraulic lines to the hydraulic motor. Note: The shaft on the hydraulic motor should be running counter clockwise. If the motor is running in the wrong direction, disconnect the hydraulic lines and reverse the hook-up.
Hydraulic Lines
Rev. Date: 12/14/10 Page 12
MODEL #5200-P
10) Coming off of the positive terminal on the truck battery, attach a 15 amp inline circuit breaker.
15 Amp Circuit Breaker
11) Run power from the truck battery to the machines electrical box.
White wire from battery to block three (3)
Red wire from battery to power distribution block
12) Attach 4” hose to the filter box inlet so that the hose sticks through the 5” hole cut into the floor of the truck.
If you need more information, please call your sales agent. Your Krendl Model #5200-P Machine is now ready for operation.
Your Krendl Model #5200-P Machine was checked and thoroughly run before it was shipped but it is always a good idea to check all belts and chains for proper tension and that all fluid levels are checked and topped off where required.
Rev. Date: 12/14/10 Page 13
MODEL #5200-P
OPERATING INSTRUCTIONS
Starting Your Krendl Model 5200-P Machine:
1) After installing your Model #5200-P according to the installation instructions, it is now time to start your machine. Again, check all fluid levels, belt tension, and that all guards are installed properly.
2) Attach the blowing hose to the machine and run the hose into the building.
3) Run the remote control cord into the building.
4) Make sure the Control Switch on the remote control cord is in the OFF position. Now, you may plug in the remote control cord.
5) With truck engine running engage PTO. Make sure PTO is running at proper speed. (With Main
Disconnect ON generator voltmeter should read 120 volts.)
6) Your machine is now ready for operation.
Note: Agitator motor and blower should only be operated with steady or constant flow of electricity between 110-120 volts.
Note: When using extension cords, wire gauge size should not be less than input cord on unit and not exceed 50' in length. (See Voltage Drop Chart Below.)
Ex: A two-wire 20-ampere circuit using 12 AWG with a one-way distance of 25 feet will drop 1.98 volts;
120 volts - 1.98 volts = 118.02 volts as the load voltage.
Rev. Date: 12/14/10 Page 14
MODEL #5200-P
Electrical Operation:
NOTE: PRESS KILL SWITCH TO IMMEDIATELY STOP MACHINE AT ANY TIME!
1. Make sure Kill Switch is out by twisting clockwise/right. (See illustration 5)
2. Turn red Main Disconnect Switch to ON position. (See illustration 5)
3. Set 4-Position Selector Switch to OFF. (See illustration 5)
4. Press green start Button. Machine will not run unless start button is pressed after Kill Switch
is out and red Main Disconnect Switch is on. (See illustration 5)
5. Select operating mode on 4-Position Selector Switch from one of the following options:
Remote:
Off:
Remote control hand pendant will control machine.
Machine will not run. (overrides remote hand pendant)
Blower: Only the blower will run continuously. (manual control at machine)
Agitator-Feed/Blower: Both the blower and the agitator-feed will run continuously. (manual control at machine)
Main Control Panel (lid closed)
Illustration 5
Main Control Panel (back)
Illustration 6
Rev. Date: 12/14/10 Page 15
MODEL #5200-P
6. When operating in Remote mode, the 4-Position Selector Switch must be set to Remote position. (See illustration 5 on page 15.)
7. Remote control hand pendant positions will be selected from the following:
BLOWER-FEED - operates both blower and agitator-feed simultaneously
OFF - (middle position) all functions stop
BLOWER - operates the blower only
8. Use the Auxiliary Outlet on the Main Control Panel for supplying continuous power (while red Main
Disconnect Switch is ON) to accessories.
Stopping Your Machine:
1) Switch the Remote Switch to “AIR ONLY” and wait until the hose is clear of all material.
2) Turn the Control Switch on the remote control cord to the OFF position.
3) Turn the Main Disconnect Switch to the OFF position.
4) Disengage the PTO.
SAFETY NOTE:
DO NOT FILL THE HOPPER TO CAPACITY AT THE END OF THE DAY. THE MATERIAL
WILL COMPRESS AND CAN CAUSE MACHINE LOCKUP DURING THE NEXT START-UP.
Mechanical Settings:
The controls of your machine contain the blower and slidegate controls to adjust your machine for each application and type of fiber. (See illustration 7 on page 17.) Blower control (air) and slidegate
(material feed) are adjusted according to:
TYPE OF MATERIAL:
HOSE:
Cellulose and fiberglass have different textures and densities that respond to machine settings.
Corrugations or roughness of interior surface, diameter, length and elevation of hose will also require varying adjustments.
WEATHER CONDITIONS: Temperature and humidity may require day to day adjustment of machine settings.
Blower Control and Slidegate General Settings:
Blower control can increase or decrease the amount of air in the system, affecting the velocity
(speed) and spread rate (coverage) of fiber. (See illustration 7 on page 17.) The blower control valve is used for controlling air pressure and amount of air flow.
Opening or closing slidegate (material feed) controls the amount of fiber dropping into the airlock which changes the production rate (lbs. per hour). (See illustration 7 on page 17.) For calibration purposes the scale located on the machine indicates how many inches the airlock slidegate is opened.
Rev. Date: 12/14/10 Page 16
MODEL #5200-P
The blower and slidegate controls working together affect the distance fiber can be blown through a hose without plugging. These controls also affect the accurate blowing of fibers for spraying applications.
These settings control the following:
• Density of fiber blown in application.
• Velocity of material impact when spraying.
• Dust on open blow.
• Material spread rate or coverage.
• Production rate (lbs. per hour blown).
Illustration 7
General Blower Control and Slidegate Settings for Open Blow:
With the slidegate closed and blower control valve on low (valve open), turn agitator-feed and
blower on. Fill hopper with insulation and adjust blower valve and slidegate. Move controls proportional to each other. (i.e. If blower valve is half open, slidegate should be half open.) As hose length is increased, air pressure/volume is increased by closing off the blower valve while closing the slidegate proportionally. This will increase the distance fiber can be blown through the hose, while decreasing the blowing production rate (lbs. per hour blown). (See illustration 7)
Shredder Assembly:
This unit is supplied with a shredder assembly; airlock/agitator speeds are preset at the factory. No further sprocket setting speeds are needed, as this system will accommodate most fibers and applications. However, the shredder and agitator direction can be adjusted as described below.
Shredder & Agitator Adjustment:
Illustration 8 Illustration 9
Unidirectional Rotation (See illustration 8) is preferred as an all-around setting for a combination of materials and applications. This setting provides the greatest coverage and best control for internal wetting (stabilized) and open blow applications.
Center-Down Rotation (See illustration 9) force feeds the fiber into the airlock at a faster rate. This direction provides the greatest production for cellulose fibers in an open attic blow application although coverage may decrease.
Rev. Date: 12/14/10 Page 17
MODEL #5200-P
GENERAL MAINTENANCE
Your Krendl Model #5200-P Machine is designed to be used with minimal maintenance for all its components. The following is only a guide; experience is the best guide for the right maintenance schedule for you.
DESCRIPTION EACH SHIFT 40
HOURS
200
HOURS
CHECK GUARDS
CHECK DRIVE ALIGNMENT & TENSION
VISUALLY INSPECT COUPLING
ELEMENTS FOR FATIGUE CRACKS
X
X
GREASE BLOWER BEARINGS
LUBRICATE DRIVE CHAINS WITH A DRY
X
(OVER 1/2”) (located behind hydraulic motor)
CLEAN BLOWER AIR FILTER
CHECK BLOWER OIL LEVEL
X
X
(needs to be changed after first 100 hours of operation and thereafter every 1000 hours)
X
LUBRICANT
GREASE SHREDDER, AIRLOCK,
AGITATOR, & JACK SHAFT BEARINGS
CHANGE BLOWER OIL
X
X
(needs to be changed after first 100 hours of operation and thereafter every 1000 hours)
1000
HOURS
X
NOTE: When further maintenance is needed, please refer back to other manufacturer’s manuals for additional assistance!
SAFETY NOTE
WHEN MAINTENANCE IS TO BE PERFORMED ON THE MACHINE ALWAYS:
1) STOP THE ENGINE COMPLETELY.
2) TURN THE IGNITION TO THE “OFF” POSITION AND REMOVE THE KEY.
Rev. Date: 12/14/10 Page 18
RECOMMENDED LUBRICATION
MODEL #5200-P
Shredder 4
(2 per side)
ALL BEARINGS:
DRIVE CHAIN:
BLOWER:
AIRLOCK REDUCER:
GREASE: MOBILITH AW-2 (NLGI grade #2)
DRY LUBRICANT (EG: DRY GRAPHITE)
OIL: PNEULUBE (Refer to blower manual)
GREASE: MOBILITH AW-2 (NLGI grade #2)
OIL: KLUBERSYNTH UH1 6-460
Agitator 6
(3 per side)
Bearing Grease Zerks
Blower 2
Jack Shaft 2
Airlock 2
(1 per side)
PTO Shaft 2
Rev. Date: 12/14/10 Page 19
MODEL #5200-P
Airlock: (Seal Replacement)
The purpose of the airlock seal is to trap air and fiber until it rotates 180 O to the 6:00 o'clock position.
At this point, fiber is pushed by air from the blower, out of the chamber. Worn or damaged seals allow air and fiber to escape back into hopper, thus reducing production and coverage. When it is necessary to replace seals, follow these directions:
Remove chain and air hoses from both input and output of airlock. Using a 9/16” socket, remove hold down bolts from airlock. Lower the front of the airlock down by loosening the jamb nuts and turning the liftbolts counter clockwise. Slide the airlock out of the machine. (See illustration 10) Airlock rotor plates that are damaged (bent) will need replaced. (Refer to Rotor Plate Replacement below.)
Take out rubber seal by removing seven plate fastening bolts and nuts and top plate. The base plate will remain attached to airlock shaft. To install a new seal, reverse procedure. Seal should be inserted tight against the back base plate, pressing the lower tabs of the seal down under the adjacent seal with a flat blade screwdriver. Make sure all bolt holes are aligned while each side of seal is equally pressed against the end plates, before tightening bolts. Seal should be bent forwards for counter clockwise rotation. (See illustration 12)
Airlock
Chain
Lift Bolt &
Jamb Nut
Hold Down Bolts Air Hose & clamps
Illustration 10
Base Plate Replacement:
1. Remove damaged baseplate assembly from shaft using ratchet drive wrench with extension and 9/16" socket.
2. Check seal for wear and damage. (Installing seal and top plate on the bench is quick and easy). Remove bolts from plate assembly and replace with new seal. Make sure seal and top plate are assembled on correct side of base plate before assembling in airlock. Seal should press backward towards top plate when installed correctly into airlock chamber. (Illustration 12)
3. Install the rotor plate assembly into the airlock. The airlock runs counter clockwise viewing it from the sprocket drive shaft. (Illustration 12) Align the base plate with holes on airlock shaft using a tapered punch. Cau-
tion: Do not mount rotor plate backwards. If installed
Rev. Date: 12/14/10
Illustration 11
Illustration 12
(Note: Entire rotor plate assembly may be removed and replaced. This procedure maybe easier than replacing just the seals.)
Page 20
MODEL #5200-P improperly, damage to seals will result and put undue stress on agitator motor. This causes overheating and poor production. Seal should be bent backward to allow for a clockwise rotation of rotor.
5. As rotor plate is installed, press bottom tab of seal under adjacent seal with flat blade screwdriver. (See illustration 12 on page 20)
Chain:
(Adjustment) (#50 Nickel Plated)
A smooth operating chain drive should have a slight sag on the idler side of the chain. New chains should be installed under slight tension as they will elongate a small amount due to seating of pins and bushings during the first few days of operation. Chain should be kept in good condition by proper lubrication (use dry film lubricant Dow 321) and occasional cleaning. Soaking chain in container of 10 weight oil will provide for internal lubrication of pins and bushings. However, excess oil must be drained and wiped away as excessive lubrication will cause fiber accumulation on chain. Worn out chain should be replaced. When chain is replaced, worn sprockets should also be replaced, preventing further damage to new chain.
Sprockets:
Check Sprockets For Wear. Misalignment and/or loose sprockets and improper chain tension causes the premature wear of chain and sprockets. All sprockets, except speed reducer and idler sprockets, have been secured with a medium grade Loctite (general purpose thread locker), to prevent gradual movement. The set screws and key are also inserted with a medium grade Loctite. If sprocket is difficult to remove, it may be heated with a propane torch to loosen.
Caution: Do not overheat sprocket or damage to bearing will result. A pulley or bearing puller can then be used to remove the sprocket and key. Replace new sprocket on shaft with key and medium grade Loctite applied to shaft. Align sprocket with corresponding sprocket, using a straightedge placed along face of teeth and tighten set screws.
Bearings:
Agitator Bearings in hopper are double-sealed, self aligning ball bearings. They have grease fittings and should be periodically lubricated. At least every 3 months. If bearings produce noise or heat (too-
hot-to-touch), the bearings should be replaced.
Agitator Bearing Replacement:
Spray area with rust penetrant (WD-40). Remove sprocket (See SPROCKET section above).
Remove the four bolts from bearing flange. Loosen set screws on bearing hub at each end of agitator shaft. Since all set screws are installed with a medium grade Loctite, a propane torch may be used to assist in removing them. Do not overheat unit, causing shaft to expand. Using a rubber mallet, drive agitator shaft an inch in one direction, creating a space between hopper and bearing unit. A bearing puller can then be used to remove the bearing. Eliminate any metal burrs from shaft with file and install new bearings with felt seals. Use a medium grade Loctite on set screws before securing bearing to shaft. (Check shaft diameter before ordering bearings)
Rev. Date: 12/14/10 Page 21
ELECTRICAL SYSTEM
MODEL #5200-P
Rev. Date: 12/14/10 Page 22
MODEL #5200-P
TROUBLESHOOTING
WARRANTY
This unit is backed by a warranty for manufacturer’s defects. If your machine needs service during the warranty time period, call your supplier immediately. DO NOT attempt to service the machine, as this voids the warranty!
IMPORTANT
At any signs of trouble with your machine, stop immediately, disconnect power and call your supplier. Refer to the GENERAL MAINTENANCE section of this manual for further details. Always disconnect the electrical power before making any inspections or repairs.
TROUBLESHOOTING
PROBLEM
1.) PTO will not engage
CORRECTIVE ACTION
A. See truck manufacturer’s PTO accessory manual.
2.) Engine starts or PTO engages but there are no other machine functions - no electrical power to the front panel
3.) Engine starts or PTO engages - but the blower will not operate
A. Check for loose or damaged wires, ground shorts.
which may be caused from machine vibration.
B. Turn off all power to machine before opening the panel box.
A. Check to see if the blower clutch is operating
B. Check clutch electrical connections.
C. Check belts, adjust or replace as required.
D. Check battery, clutch will not cycle or will slip if battery is not fully charged.
E. Check that blower can be turned by hand. If not, blower may be tied up.
F. Weak/Worn clutch- replace or rebuild as required.
4.) Insufficient air - clutch is operating
Air Filter
Illustration 14
Blower Control
A. Check that the blower control valve isn’t fully open.
Close or adjust the handle control as needed.
You should be able to get over 4 p.s.i. of air on gauge. See illustration 14.
B. Check that the blower relief valve is not stuck open.
See illustration 15 on page 24.
C. Check if blower air filter and intake hose is clogged.
See illustration 14.
D. Check airstream and bypass air hose connections, clamps, etc.
E. Check that the one way air check valve isn’t stuck closed. See illustration 15 on page 24.
Rev. Date: 12/14/10 Page 23
Check Valve Relief Valve
Illustration 15
5.) No material flow - clutch is operating
MODEL #5200-P
F. Check belts, adjust /replace as required and check for missing keys under drive pulleys.
G. Fiber hose plugged. Make sure the air bypass valve is completely closed, then switch machine to blower only to blow out the hose. If problems still occur, try hitting the hose where it is plugged to release the material.
H. If the airlock seals and/or airlock components are worn or damaged, replace all the parts as needed.
A. Check material level in main hopper.
B. If the material slide gate is closed or adjusted in too far for material feed rate, open the slidegate.
C. Check the belts coming from the main drive shaft pulley to the reducer shaft drive pulley and blower shaft drive pulley. Adjust or replace belts as required. Check for missing keys under the drive pulleys.
D. Check chains, adjust or replace as required.
Check for missing keys under drive sprockets.
E. Fiber hose plugged. Make sure the air bypass valve is completely closed, then switch machine to blower only to blow out the hose. If problems still occur, try hitting the hose where it is plugged to release the material.
SPARE PARTS LIST
The following is a recommended spare parts list. To keep your machine up and running, these are the parts we suggest you keep on hand for your Model #5200 Krendl Machine.
PART
NUMBER
250503-8
8036-2
8065-2
1032
5200-72
5200-38
5200-37
5200-9M
150526
DESCRIPTION
AGITATOR BEARINGS
SHREDDER BEARINGS
AIRLOCK BEARINGS
JACK SHAFT BEARINGS
V-BELT PTO SHAFT TO GENERATOR
V-BELT PTO SHAFT TO JACKSHAFT
V-BELT JACKSHAFT TO BLOWER
AIRLOCK SEALS
#50 MASTER LINK
QUANTITY
REQUIRED
1
6
4
2
2
1
1
6
4
Rev. Date: 12/14/10 Page 24
PARTS LIST
#5200 Exploded Parts View
MODEL #5200-P
Rev. Date: 12/14/10
Unidirectional Center - Down
Page 25
#5200 Exploded Parts View
MODEL #5200-P
Rev. Date: 12/14/10 Page 26
#5200 Exploded Parts View
MODEL #5200-P
Rev. Date: 12/14/10 Page 27
19
19-1
19-2
19-3
20
21
22
23
15
16
17
18
12
13
13
14
Item#
1
2
2-1
3
8
9
10
11
4
5
6
7
36
37
38
39
32
33
34
35
39-1
39-2
39-3
40
41
28
29
30
31
24
25
26
27
Rev. Date: 12/14/10
109809
109801
5200-112
2502028
5200-5
5200-6
5200-9-ASSY
5200-7
5200-9M-2PLYF
5200-8
8065-3
8065-2
5200-43
5200-54
339A
RM-OTH095-MI
Part#
5200-1
4000-15
4000-29
5200-47
250503-7
250503-8
5200-42
250504
250505-1
40052
150513
FSB120
561
109806
5200-10
5200-11-A
5200-11-B
517-7
8036-2
8037
448
5200-3
5200-98
5200-102
5200-87
5200-86
5200-89
5200-99
16-2 SJ
434
5200-114
250325
5200-111
#5200 Exploded Parts List
Description
Base, (Upper&Lower Portion)
Agitator, Hopper, 16 Tine
Agitator, Middle & Shredder, 17 Tine (2)
Guard, Chain
Seal, Felt, 1 1/4”
Bearing, Flange, 4-Bolt, 1 1/4” (6)
Sprocket, #50 40T x 1 1/4”HT (2)
Sprocket, #50 20T x 1 1/4” (3)
Sprocket, #50 25T x 1 1/4” (2)
Nut, 1” x 1” x 1/2” (Plated)
Sprocket #50, Idler, 15HT x 5 (5)
5/8” X 3/4” Shoulder Bolt (5)
1/4” x 1/4” x 1” Key (3)
Chain, #50 x 47 1/4”Long (Center Down)
Chain, #50 x 55” Long (Unidirectional)
Chain, #50 x 38 1/2” Long
Chain, #50 x 80” Long
Chain, #50 x 41” Long
Chamber, Airlock, 5200
Shaft, Airlock, 5200
Seal Assy, 5200, 18” (2 PLY/FAB) (6)
Plate, Top, Airlock (6)
Seal, Airlock (6)
Plate, Bottom, Airlock (6)
Felt Seal, 1 1/2” (2)
Bearing, 4-Bolt, 1 1/2” (2)
Sprocket, #50 20T x 1 1/2”
3/8” Square Stock, 1 1/2” Long
Clamp, Hose, 3” (12)
Hose, Radiator, 3” x 23”
Shredder Box
Shredder Agt., Short (18 Tine)
Shredder Agt., Long (20 Tine)
Seal, Felt Airlock 1” Bore (4)
Bearing, 2-Bolt, 1” (4)
Sprocket, #50, 11T x 1” (2)
Key, 3/16” x 3/16” x 7/8”
Mount, Reducer, 5200
Reducer, 5200
Bushing, JA 3/4”
Hub, F/E4 Element (2)
Element, Coupling, E4
Bushing, JA 1”
Clutch, Shaft Mount, 5 Groove
Wire, 16-2 SJ00W, 18” long
Plug, NEMA# L6-15P
Spring, 9/16 x 6 x .072 (2)
Key, 1/4” x 1/4” x 2” Long (5)
Jack Shaft, Reducer
MODEL #5200-P
Page 28
5200-25
5200-104
5200-109
150314
5200-31
5200-95
5200-94
5200-110
4200-4
250300-1
5200-101
16-2 SJ
1538
5200-37
8306SB-1
5200-76
5200-61
4200-12
RM-OTH095-MI
5200-62
250539
5200-66
5200-65
IWS-32
IWS-25A
Part#
1032
5200-51
5200-38
5200-20
2100-8
5200-28
5200-30
5200-72
5200-57-A-R1
5200-56
5200-59
5200-64
8051
81-1063
5200-63
FN014
5200-81
5200-106
RM-OTH103-MI
H440
5200-105
5200-22
5200-97
5200-96
5200-108
86
87
88
89
79
80
81
82
83
84
85
75
76
77
77-1
77-2
78
71
72
73
74
67
68
69
70
61
62
63
64
65
66
54
55
56
57
58
59
60
47
48
49
50
51
52
53
Item#
42
43
44
45
46
Rev. Date: 12/14/10
#5200 Exploded Parts List
Description
Bearing, 1” P.B. (2)
Shim, Bearing (2)
Belt, 3/3VX425
Generator, 6000 watt
Mount, Motor
Pulley, 3GR3V3.65 SH
Bushing, SH 1 1/8”
V-Belt, 3/3VX475
Panel Box Assy
Filter Box
Guage, Pressure, 0-10 PSI
Elbow, 2”, 90 Street
Ball Valve, 2”
Filter, F/250300-2-R1 (Blue)
Cover, Filter
5/16-18 Locknut-Crimped
Adapter, 2” Barb
Muffler Clamp (2)
Pipe, Exhaust Flex (70”)
Hose, 3” Master Flex (44”)
Idler Bracket (2)
Tensioner, H.D., Rotary (2)
Idler, 3GR3V3.35
Idler, 2GR3V3.35
Motor, Hydraulic Pump
Pulley, 8GR3V4.75
Bushing, SK 1 1/2” (2)
Mount, Hydraulic Pump Motor
Bearing, P.B. 1 1/2” (2)
Bushing, SK 1”
Hub, F/E-20 Element (2)
Element, Coupling,E-20
Shaft, Drive, PTO
Blower Mount
Blower, Rotary, 10HP, #4007
Clutch, Shaft Mount, 2 Groove
Wire, 16-2 SJ00W, 13” long
Plug, NEMA# L5-15P
Belt, 2/3VX450
Nipple, 3”x4” (Painted)
Elbow, 3” 90 Black Pipe (Painted)
Pressure Relief Tube
Pressure Reflief Valve
3” Heater Hose, 19” long
Adapter, 2” Long, Male
Check Valve, 3”
Elbow, Pressure Guage
Elbow, Inlet
Male Connector (2)
Water Line, 1/4” x 6’ w/swivel
MODEL #5200-P
Page 29
Part#
IWS-H-1/4
IWS-29
5200-45
5200-46
5200-60
FSB078
FN015
5200-58
5200-74
5200-67
5200-69
5200-68
5200-2
109078-1E
102020
109078-1D
109078-1-1
109078-1-2
5200-49
5200-48
5200-50
340
RM-OTH108-MI
5200-12-B
541
FSB080
8065-6
8076
508-1
508-2
543-M-18
4000-47
543-M-75
190
Item#
89-1
89-2
108
109
110
111
112
113
114
115
101
102
103
104
105
106
107
116
117
118
119
120
121
94
95
96
97
98
99
100
90
91
92
93
#5200 Exploded Parts List
Description
1/4” Hose
Swivel, SAE 37
Slidegate, 5200
Crankrod w/ Handle Bracket
Handle
Pin, Cotter, 1/8” x 1”
N 3/8-16 Lock Nut-Crimped
Support, Crankrod
Cover, Slidegate Cable 18 1/4”
Cable, Slidegate, Indicator, 33”
Mount, Indicator Cable
Cover, Slidegate Indicator
Hopper Extension, 5200
Finger Bracket RH
Latch Finger (2)
Finger Bracket, LH
Clevis Pin (3)
Roll Pin (3)
Guard, Side (Back Side)
Guard, Side (Crankrod Side)
Tube, Output
4” Hose Clamp (4)
4 1/4” Radiator Hose, 5” long
Hood, PTO
Hinge Pin (2)
Roll Pins (2)
Compression Latch (3)
Enclosure
Contact Block
Killswitch
Connector, Conduit, 1/2” Straight
Spacer Block
Conduit, 1/2” Flexible, 5ft long
Link, Chain, 1/2 #50 NP (Not Shown)
MODEL #5200-P
Rev. Date: 12/14/10 Page 30
MODEL #5200-P
12 V.D.C Electrical Exploded Parts View
12 V.D.C.
50-30
50-31
50-32
50-33
50-34
50-35
50-36
50-37
50-38
50-39
50-22
50-23
50-24
50-25
50-26
50-27
50-28
50-29
Item #
50-1
50-2
50-3
50-4
50-5
50-6
50-7
50-8
50-9
50-10
50-11
50-12
50-13
50-14
50-15
Part #
5200-57-1
1563
1542-A
KMC-021
1542-B
KMC-015
543-M-2
KMC-022
151080-49
ELU07-C
151080-61
Description
Box, Electrical
Plate, Backing, 9” x 11 1/8”
Receptacle, NEMA# L5-15R
Decal, Blower Motor (not shown)
Receptacle, NEMA# L6-15R
Decal, Agitator (not shown)
Receptacle, RC Plug #509-1050 (remote)
KMCS-024 Decal, (SP) Remote Control
132-B Receptacle, NEMA# 6-15R (2)
KMCS-131 Decal,(SP) 12 Volt D.C. Outlet
1531-B Voltmeter, 0-300V
Decal, Do Not Operate Below 120V
Clamp, f/1 3/8” Din Rail (4)
Dinrail, 1 3/8”, 8 1/2” Long
Terminal Block, Small (3)
50-16 543-M-33-D* Operator Handle Assembly
50-17 543-M-33-D Switch, Disconnect 40A #XA324BY
50-18
50-19
543-M-22
543-M-15
Switch, 4-position Selector
Contact Block, for Selector Switch(white) #KA-1 (not shown)
50-20
50-21
543-M-16
KMC-068
Contact Block for Selector Switch(red) #KA-3 (3) (not shown)
Decal, (Remote/Manual - 4-Position)
543-M-59
543-M-60
260302-4
251080-5
433-E
543-M-38
508-2
8075-1
Switch, Pushbutton ON
Start Legend Plate
Cover Plate, Weatherproof
GFCI Outlet
Manual Reset, 15 AMP
Alarm for Pre-Alarm System, 24V
Switch, Kill
Contactor, Kill Switch (not shown)
KMCS-012 Decal, (SP) Kill Switch (not shown)
4000-32-3 Socket, (4)
4000-32-7
4000-32-8
Timer, On Delay
Clip, Timer Relay
4000-32-2
4000-32-4
543-M-18
121
Relay, 12VDC Cube (3)
Relay Clips (3)
Connector, Conduit,1/2" Straight (2)
Cord Clamp, 3/4"
KMCS-132 Decal,(SP) 12 Volt D.C. ON/OFF Outlet
1534 Terminal Board
Rev. Date: 12/14/10 Page 31
MODEL #5200-P
BRIDGING
CFM
CHECK VALVE
COMMERCIAL
SPRAY-ON
COVERAGE
NEW CONSTRUCTION
WALL CAVITY SPRAY
PSI
PRODUCTION RATE
RPM
R-VALUE
RETRO-SIDEWALL
SETTLED DENSITY
SETTLING
Rev. Date: 12/14/10
GLOSSARY
A tendency for fiber to cling in the hopper forming an air pocket above the airlock. This hinders the normal feeding process of the machine.
(Cubic feet per minute). A measurement of volume or quantity of air flowing at a certain rate, or air moving capability, of a blower. It is the volume of air moved per minute. Higher volume provides increased coverage and velocity of fiber as it leaves the hose.
A valve that allows air to flow in one direction only. When mounted on the outlet of the blower, it protects the blower from fiber contamination through the air hose when using one blower. When the blower stops, the valve closes.
The application of fiber with adhesive to a surface which will remain exposed. The application must therefore be impacted in a smooth, uniform manner.
Refers to the amount of fiber coverage, usually measured in square feet, according to the R-value desired. This information is given on the fiber package.
The spray application of fiber with water or adhesive into an exposed wall cavity to later be covered with drywall sheathing, etc.
Pounds of pressure per square inch of force exerted on a surface by air or liquid. High-pressure blowers push the fiber through the hose.
Higher pressure provides less hose plugging and increased compaction in side wall.
Pounds of fiber blown per hour.
(Revolutions per minute). Speed at which the shaft of a rotating device
(i.e. blower fan, agitator) is moving.
Resistance value. A precise measurement of the insulation’s resistance to heat transfer. The higher the resistance value, the slower the heat will transfer through the insulating material.
This refers to the installation of fiber into an unexposed wall cavity. Fiber is usually installed through holes drilled into the exterior siding.
The point at which the fiber will not continue to settle further. Any insulation blown will have a certain amount of progressive settling that occurs over a period of time. Following the fiber manufacturer’s recommendations for bag rate coverage will provide useful information to accommodate for settling.
Compression or compaction of insulation fibers caused by the weight of the material, vibration of structure, temperature, and humidity cycles.
Page 32
DATE
MODEL #5200-P
SERVICE RECORD
MAINTENANCE PERFORMED COMPONENTS REQUIRED
Rev. Date: 12/14/10 Page 33

Public link updated
The public link to your chat has been updated.
Advertisement