FXDQ-A_Slim Concealed Ceiling Unit_UKEPLEN15-944

FXDQ-A_Slim Concealed Ceiling Unit_UKEPLEN15-944
Slim concealed ceiling unit
Ducted - VRV indoor unit
FXDQ-A
Applications from hotels to retail to offices
The slim concealed unit has a very wide range of
capacities to suit an array of applications from hotels
to retail to offices.
The Daikin VRV indoor unit range is one of the widest
on the market, offering no less than 26 stylish and
elegant models in 116 different variants – all designed
to maximise comfort, minimise operating noise and
simplify installation and servicing.
Designed to fit rooms of any size and shape, Daikin
indoor units are also user friendly, ultra reliable, easy
to control and quiet in operation.
All indoors units comply with the Ecodesign
legislation by adopting DC fans in all indoor units,
improving their energy efficiency.
Features and benefits:
> Compact dimensions, can easily be mounted in a ceiling void of only 240mm
> Blends unobtrusively with any interior décor: only the suction and discharge
grilles are visible
> 15 class unit especially developed for small or well-insulated rooms,
such as hotel bedrooms and small offices
> Low energy consumption thanks to DC inverter fans
> Medium external static pressure means units can be used with flexible ducts
of varying lengths
> Standard drain pump with 750mm lift
750 mm
200mm
FXDQ15-32A
BRC1E52A/B
BRC4C65
Slim concealed ceiling unit
FXDQ-A
Indoor unit
Cooling capacity
Heating capacity
Power input - 50Hz
Casing Colour
Dimensions
Required ceiling void >
Weight
Fan-Air flow rate - 50Hz
Fan-External static
pressure - 50Hz
Nom.
Nom.
Cooling
Heating
Nom.
Nom.
Unit
HxWxD
FXDQ15A
FXDQ20A
FXDQ25A
FXDQ32A
FXDQ40A
FXDQ50A
FXDQ63A
1.7
1.9
2.2
2.5
2.8
3.2
3.6
4.0
4.5
5.0
0.078
0.075
5.6
6.3
0.099
0.096
7.1
8.0
0.110
0.107
kW
kW
kW
kW
0.071
0.068
Galvanised steel / Non painted
Unit
Cooling
High/Nom.
High/Nom./Low
mm
mm
kg
m³/min
Pa
Sound power level
Sound pressure level
Refrigerant
Piping connections
Cooling
Nom.
Cooling
High/Nom./Low
Type
Liquid/OD/Gas/OD/Drain
dBA
dBA
Power supply
Current - 50Hz
Phase/Frequency/Voltage
Maximum fuse amps (MFA)
Hz/V
A
200x750x620
200x950x620
200x1,150x620
26
29
16.5/14.5/13.0
240
22
7.5/7.0/6.4
8.0/7.2/6.4
10.5/9.5/8.5
12.5/11.0/10.0
44/15
51
33/31/27
52
34/32/28
53
35/33/29
30/10
50
32/31/27
R-410A
6.35/12.7/VP20
(I.D. 20/O.D. 26)
mm
54
36/34/30
9.52/15.9/VP20
(I.D. 20/O.D. 26)
1~/50/ 220-240
16
Options & accessories
FXDQ 15~63A

*4
BRC4C65






KRCS01-4B
K.RSS
-
Other options
Decoration panel (obligatory for cassette units, optional for others,
rear panel for FXLQ)
Kit for mounting of decoration panel direct onto unit
Panel spacer for reducing required installation height
Sealing kit for 3-directional or 2 directional air discharge
Fresh air intake kit
Air discharge adapter for round duct
Filter chamber for bottom suction
Replacement long life filter
Drain pump kit
Sensor kit
Noise filter (for electromagnetic use only)
FXDQ 15~63A
standard
KEK26-1A
*4 Not recommended because of the limitation of the functions
KRP4A54
KRP2A53
KRP1B56
DTA114A61
DTA10A53
KRP1B101
KJB212A
KJB311A
-
The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin
UK. Daikin UK has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty
is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products
and services presented therein. Specifications are subject to change without prior notice. Daikin UK explicitly
rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or
interpretation of this leaflet. All content is copyrighted by Daikin UK.
Daikin Airconditioning UK Limited The Heights Brooklands Weybridge Surrey KT13 0NY Tel 0845 6419000 Fax 0845 6419009 daikin.co.uk
UKEPLEN15-944 / 02.15 / DesignHQ / Copyright 2015 Daikin
Adapters and controls
BRC1E52A/B Premium wired remote control with full
text interface and back light
BRC1D52 Standard wired remote control with weekly
timer
Infrared remote control including receiver
BRC2E52A Simplified wired remote control for heat
recovery
BRC3E52A Simplified wired remote control for heat
pump
DCS302C51 Central remote control
DCS301B51 Unified ON/OFF control
DST301B51 Schedule timer
DCM601A51 Inteligent Touch Manager
External wired temperature sensor
External wireless temperature sensor
Adaptor for wiring (interlock for fresh air intake fan)
Wiring adapter for external monitoring/control via dry
contacts and setpoint control via 0-140 Ω
Wiring adapter for external central monitoring /
control (controls 1 entire system)
Wiring adapter with 4 output signals (compressor /
Error, Fan, Aux. heater, Humidifier output)
Wiring adapter with 2 output signals (compressor /
Error, Fan)
Adapter for multi-tenant (24VAC PCB power interface)
External control adapter for outdoor unit
Installation box / Mounting plate for adapter PCBs
(For units where there is no space in the switchboard)
Connector for forced-off contact
Connection to centralised control
Electrical box with earth terminal (2 blocks)
Electrical box with earth terminal (3 blocks)
Electrical box with earth terminal
Digital input adapter
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement