Athena RMB-6 Brochure

Athena RMB-6 Brochure
11153 Athena RMB6_900M244U00_11129 ATH 2/8/13 10:36 AM Page 1
RMB/6 Non-Modular Hot Runner Controller
Hot Runner Temperature Control for 6 Zones
Athena’s new RMB/6 Non-Modular Hot Runner control
system offers 6 zones of microprocessor-based control.
The system delivers more functionality with a full
featured easy-to-use Operator Keypad/LCD display
and 6 discrete indicators of Heat, Boost, Closed Loop,
Open Loop, Idle, and Alarm.
▲ Compact package design
▲ 6 zones of control with 15 amps per zone
▲ Accepts “J’ or “K” thermocouple input, grounded
or ungrounded
▲ CompuStep bake out feature prevents moisture
at startup
▲ Built-in loop break, short, open, and reverse
thermocouple
▲ Adjustable set point limits
▲ “Boost” mode for temporary % of power
output increase
▲ Remote input standby function
▲ Remote alarm output contacts
▲ Fan cooled
Ordering Information
R M B
6
0
Communications
Market
Zone Count
0 = None
D = Domestic
X = Export
E = CE
06 = 6
Future
Options
Consult Factory
11153 Athena RMB6_900M244U00_11129 ATH 2/8/13 10:36 AM Page 2
RMB/6 Non-Modular Hot Runner Controller
Technical Specifications
Technical Operating Limits
Input Specifications
Absolute Voltage Limits
240 Vac +10/-20%
Input Line Voltage
Nominal 100 to 240 Vac
Ambient Temperature
Thermocouple (T/C Sensor)
Type “J” or “K” grounded
or ungrounded
32 to 122°F (0 to 50 °C)
External T/C Resistance
Max 100 ohms for rated
accuracy
Relative Humidity
Tolerance
90% non-condensing
T/C Isolation
Frequency
50-60 Hz
Channel to channel
common mode
voltage ± 1.5 Vdc
Cold Junction
Compensation
Performance Specifications
Auto Control Mode
CompuCycle system
(PWM, 200 msec)
Control Accuracy
± 0.1°F (± 0.1°C)
dependant on the total
thermal system
Temperature Stability
± 0.5% of full scale over the
ambient range
Calibration Accuracy
Better than 0.2% of full scale
Power Response Time
Better than 400 ms
Process Sampling
100 ms
°F/°C
Field Configurable
Input Impedance
10 megohms
Input Protection
Diode clamp RC filter
Input Dynamic Range
Greater than 999°F (537°C)
Common Mode
Rejection Ratio
Greater than 100 db
Power Supply
Rejection Ratio
Greater than 70 db
Output Specifications
Voltages
240 Vac nominal, single
phase 100 Vac available
Power Capability
15 amperes, 3600 watts @
240 Vac per zone
Overload Protection
Triac and load use high
speed fuses, Type (ABC)
Power Line Isolation
a: T/C open, T/C reverse
Shutdown and open heater
override CompuStep
Optically and transformer
isolated from ac lines.
Isolation voltage is greater
than 2500 volts
Output Drive
Internal solid state Triac
b: Manual mode overrides
T/C open, T/C reverse
Human Interface (HMI)
CompuStep System
Control Mode
PWM
CompuStep System
Duration
Approximately 5 min
CompuStep System
Output Voltage
PWM % with zero cross
CompuStep System
Override Temp
200°F (93°C)
Operation Mode Priority
Automatic, better than 0.02°
F/°F (0.03°C/°C)
Operator Keypad
Dimensions
8 Control Switches, 6 Status LED’s per zone
Height
6˝
Width
17-1/4˝
Depth
13-1/2˝
Weight
17 lbs.
Degrees “F” and “C” Status indicators
LCD Display, 2 Line x 24 Characters
Athena Controls, Inc.
5145 Campus Drive • Plymouth Meeting, PA 19462-1129 USA
Toll free: 1.800.782.6776 • Tel: 1.610.828.2490
Fax: 1.610.828.7084 • E-mail: [email protected]
www.athenacontrols.com
©Copyright, Athena Controls, Inc., 2013
Printed in USA
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement