Multi-Channel Antenna Calibration Reference Solution

Multi-Channel Antenna Calibration Reference Solution
Keysight Technologies
Multi-Channel Antenna
Calibration, Reference Solution
Configuration
Guide
02 | Keysight | Multi-Channel Antenna Calibration Reference Solution - Configuration Guide
OVERVIEW
This configuration guide contains information to help you configure your Keysight Technologies, Inc. Multi-Channel Antenna Calibration
(MAC), Reference Solution and tailor the system to meet your requirements.
Table of contents
Page number
A: Configure the M9703A AXIe digitizer.........................................................................................................................................3
B: Configure the M9362AD01 PXIe quad downconverter.............................................................................................................3
C: Add M9352A PXIe hybrid IF amplifier/attenuator......................................................................................................................4
D: Select and configure the LO for the M9362AD01 PXIe quad downconverter..........................................................................4
E: Select and configure a RF/microwave source for antenna receive calibration .......................................................................5
F: Select and configure AXIe chassis..............................................................................................................................................6
G: Select and configure PXIe chassis.............................................................................................................................................6
H: Select and configure embedded or external controller............................................................................................................7
H1: For M9037A high-performance PXIe embedded controller.........................................................................................7
H2: For M9536A AXIe embedded controller........................................................................................................................8
H3: For external controller....................................................................................................................................................8
I: Select solution start-up kit and example software.....................................................................................................................9
J: Reference solution block diagram..............................................................................................................................................9
K: Physical computer and PCIe® connections...............................................................................................................................10
L: Select services...........................................................................................................................................................................11
M: Related literature......................................................................................................................................................................12
03 | Keysight | Multi-Channel Antenna Calibration Reference Solution - Configuration Guide
A. Configure the M9703A AXIe digitizer (occupies 1 AXIe slot)
Recommended options for Multi-Channel Antenna Calibration, Reference Solution indicated below.
Not all M9703A product options are shown below. See www.keysight.com/find/M9703A for more detail.
Step 1. Start with M9703A AXIe digitizer base configuration (select quantity required)
Qty 1
The M9703A includes:
Number of digitizer channels: 8
Bandwidth: 650 MHz
Sample rate: 1 GSa/s
Memory, per channel: 64 MSa
Software, example programs, and product information on CD
Return to Keysight warranty 3 years
Step 2. Choose sample rate
Qty 1
M9703A-SR1
1 GSa/s
M9703A-SR2
1.6 GSa/s
M9703A-DDC
Real-time DDC
Included in base configuration of M9703A
Step 3. Add DDC
Qty 1
Step 4. Choose frequency range
Qty 1
M9703A-F05
650 MHz maximum
M9703A-F10
1 GHz path enabled
M9703A-M10
1 GB, 64 MS/channel
M9703A-M40
4 GB, 256 MS/channel
M9703A-M16
16 GB, 1024 MS/channel
Included in base configuration of M9703A
Step 5. Choose memory
Qty 1
Included in base configuration of M9703A
Step 6. Add specification optimization
Increases dynamic range
M9703A-FRF
High frequency specs optimization
B. Configure the M9362AD01 PXIe quad downconverter (occupies 3 PXIe slots)
Recommended options for Multi-Channel Antenna Calibration, Reference Solution indicated below.
Step 1. Start with M9362AD01 base configuration (add and configure two M9362AD01 for each M9703A)
Qty 2
The M9362AD01 includes:
Number of downconverter channels: 4 each
Bandwidth: 1.5 GHz
Software, example programs, and product information on CD
Return to Keysight warranty 3 years
Step 2. Choose frequency range
Qty 2
M9362AD01-F26
10 MHz − 26.5 GHz
M9362AD01-F40
10 MHz − 40 GHz
04 | Keysight | Multi-Channel Antenna Calibration Reference Solution - Configuration Guide
C. Add the M9352A PXIe hybrid IF amplifier/attenuator (occupies 1 PXIe slot)
Step 1. Add one M9352A-H01 amplifier for each M9362AD01 quad downconverter
Qty 2
The M9352A-H01 includes:
Number of amplifier channels: 4 each
Bandwidth: 1 GHz
Software, example programs, and product information on CD
Return to Keysight warranty 1 year
D. Select and configure the LO for the M9362AD01 PXIe quad downconverter
Recommended options for Multi-Channel Antenna Calibration, Reference Solution indicated below. Not all N5183B or N5193A product
options are shown below. See www.keysight.com/find/N5183B or www.keysight.com/find/N5193A for more detail.
Step 1. Select LO base configuration
Qty 1
N5183B MXG microwave signal generator
N5193A UXG agile signal generator
Other microwave signal generator
Step 2. Choose frequency range
For N5183B:
Qty 1
N5183B-520
9 kHz − 20 GHz
N5183B-532
9 kHz − 31.8 GHz
N5183B-540
9 kHz − 40 GHz
N5193A-520
10 MHz to 20 GHz
N5193A-540
10 MHz to 40 GHz
For N5193A:
Step 3. Select other options as needed
For N5183B:
Qty 1
N5183B-1E1
Step attenuator
N5183B-1EA
High output power
N5183B-UNY
Low phase noise
N5183B-UNZ
Fast frequency switching
1CM010A
4U rack mount kit
N5193A-EP1
Enhanced phase noise
N5193A-FR1
1 Hz frequency resolution
N5193A-SS1
1 µs switching speed
N5193A-SS2
250 ns switching speed
34192A
3U rack mount kit
For N5193A:
Standard product includes installation guide, electronic documentation set (CD-ROM), adapters, country specific power cord
and return to Keysight 3 year warranty.
05 | Keysight | Multi-Channel Antenna Calibration Reference Solution - Configuration Guide
E. Select and configure a RF/microwave source for antenna calibration
Recommended options for Multi-Channel Antenna Calibration, Reference Solution indicated below. Not all N5193A or E8257D product
options are shown below. See www.keysight.com/find/N5193A or www.keysight.com/find/E8257D for more detail.
Step 1. Select source base configuration
Qty 1
N5193A UXG agile signal generator
E8257D PSG microwave signal generator
Standard product includes installation guide, electronic documentation set (CD-ROM), adapters, country specific power cord
and return to Keysight 3 year warranty.
Other microwave signal generator
Step 2. Choose frequency range
For N5193A:
Qty 1
N5193B-520
10 MHz to 20 GHz
N5193A-540
10 MHz to 40 GHz
E8257D-520
9 kHz − 20 GHz
E8257D-532
9 kHz − 31.8 GHz
E8257D-540
9 kHz − 40 GHz
For E8257D:
Step 3. Select other options as needed
For N5193A:
N5193A-AT1
Mechanical and solid-state attenuator
N5193A-EP1
Enhanced phase noise
N5193A-FR1
1 Hz frequency resolution
Qty 1
N5193A-PM1
Pulse modulation
Qty 1
N5193A-SS1
1 µs switching speed
N5193A-SS2
250 ns switching speed
N5193A-UNT
AM, FM, phase modulation, and narrowband chirp
34192A
3U rack mount kit
E8257D-1E1
Step attenuator
E8257D-1EA
High output power
E8257D-UNX
Ultra-low phase noise
E8257D-UNY
Enhanced ultra-low phase noise
1CM014A
4U rack mount kit
Qty 1
Qty 1
For E8257D:
06 | Keysight | Multi-Channel Antenna Calibration Reference Solution - Configuration Guide
F. Select and configure AXIe chassis
Recommended options for Multi-Channel Antenna Calibration, Reference Solution indicated below. Not all M9502A and M9505A product
options are shown below. See www.keysight.com/find/M9502A or www.keysight.com/find/M9505A for more detail.
Step 1. Select AXIe chassis to fit number of M9703A AXIe digitizers selected
Qty 1
The M9502A AXIe chassis (supports up to 2 M9703As for a total of 16 channels) includes:
Number of AXIe slots: 2
AXIe filler module
Software, example programs, and product information on CD
Return to Keysight warranty 3 years
The M9505A AXIe chassis (supports up to 5 M9703As for a total of 40 channels) includes:
Number of AXIe slots: 5
AXIe filler modules
Software, example programs, and product information on CD
Return to Keysight warranty 3 years
The M9514A AXIe chassis (supports up to 13 M9703As for a total of 104 channels) includes:
Number of AXIe slots: 13
Software, example programs, and product information on CD
Return to Keysight warranty 3 years
AXIe filler modules must be ordered separately
Step 2. Select rack mount hardware (optional)
Y1225A
Rack mount kit for M9502A
Y1226A
Rack mount kit for M9505A
Y1229A
Rack mount kit for M9514A
Step 3. Select AXIe filler modules for M9514A (required if using M9514A)
Order one filler module for each empty slot
Y1221A
AXIe filler module: single slot
Step 4. Select power cable for M9514A (required if using M9514A)
Y1235A
1-phase without neutral, 250 VAC, NEMA L6-30
Y1236A
3-phase WYE with neutral, 240/415 VAC, IEC 60309
Y1237A
3-phase DELTA with neutral, 250 VAC, NEMA L15-30
Y1238A
3-phase WYE with neutral, unterminated
G. Select and configure PXIe chassis (17 instrument slots)
Recommended options for Multi-Channel Antenna Calibration, Reference Solution indicated below. Not all M9018A product options
are shown below. See www.keysight.com/find/M9018A for more detail.
Step 1. Select PXIe chassis to fit number of slots required for attenuators and downconverters selected
Qty 1
The M9018A PXIe chassis includes:
Standard (non-EMC) PXI blank filler panel kit
Software, example programs, and product information on CD
Return to Keysight warranty 3 years
Step 2. Select rack mount kit (optional)
Y1215B
Flush mount kit for M9018A
Y1216A
Recess mount kit for M9018A
Y1217A
Rack rail kit for M9018A
Step 3. Select EMC filler panels (optional)
Y1213A
PXI EMC filler panel kit - 5 slots
07 | Keysight | Multi-Channel Antenna Calibration Reference Solution - Configuration Guide
H. Select and configure embedded or external controller (PC host)
Select one of the following: M9037A (H1), M9536A (H2), or external PC (H3)
H1. For M9037A high-performance PXIe embedded controller (occupies 1 PXIe system slot)1
Recommended options for Multi-Channel Antenna Calibration, Reference Solution that includes both an AXIe and PXIe chassis,
indicated below. See www.keysight.com/find/pxie-multichassis for alternate configuration methods.
Step 1. Select M9037A PXIe embedded controller
Qty 1
The M9037A includes:
Intel i7-4700EQ quad-core processor, 2.4 GHz, 8 thread, 4 GB RAM and 240 GB SSD
Two DisplayPort, four USB 2.0, two USB 3.0, GP-IB, two Ethernet, PXI Trigger
Front Panel x8 PCIe for connecting a second PXIe or AXIe chassis
Software, example programs, and product information on CD
Return to Keysight warranty 3 years
Step 2. Choose memory
Qty 1
M9037A-M04
Standard 4 GB
M9037A-M08
Memory upgrade from 4 GB to 8 GB RAM
M9037A-M16
Memory upgrade from 4 GB to 16 GB RAM
Step 3. Choose an operating system
Qty 1
M9037A-WE3
Microsoft Windows Embedded Standard 7 (32-bit)
M9037A-WE6
Microsoft Windows Embedded Standard 7 (64-bit)
Step 4. Select accessories (optional)
Y1206A
USB keyboard and mouse
Y1260A
GP-IB cable
Y1261A
DisplayPort to DVI adapter
Y1262A
DisplayPort cable
Y1263A
DisplayPort to VGA adapter
Y1264A
Spare SSD with carrier: WES 7/32
Y1265A
Spare SSD with carrier: WES 7/64
1. The M9037A embedded controller occupies the M9018A system slot and the empty space to the left of the system slot.
08 | Keysight | Multi-Channel Antenna Calibration Reference Solution - Configuration Guide
H2. For M9536A AXIe embedded controller (occupies slot #1 of the AXIe chassis)
Recommended options for Multi-Channel Antenna Calibration, Reference Solution that only uses an AXIe chassis (with no PXIe chassis), indicated
below.
Step 1. Select M9536A AXIe embedded controller
The M9536A includes:
Intel Xeon L5518 quad-core processor, 2.13 GHz, 8 GB RAM and 160 GB SSD
One VGA, three USB 2.0, two Ethernet, serial port
Software, example programs, and product information on CD
Return to Keysight warranty 3 years
Step 2. Upgrade memory (optional)
M9536A-M16
Memory upgrade from 8 GB to 16 GB RAM
Step 3. Choose an operating system
Qty 1
M9536A-WE3
Microsoft Windows Embedded Standard 7 (32-bit)
M9536A-WE6
Microsoft Windows Embedded Standard 7 (64-bit)
Step 4. Select accessories (optional)
Y1206A
USB keyboard and mouse
Y1207A
Spare SSD: WES 7/32
Y1208A
Spare SSD: WES 7/64
H3. For an external controller 2
It is recommended that the external PC controller have at least two PCIe slots, one for each primary chassis (AXIe and PXIe) .
See www.keysight.com/find/pxie-multichassis for alternate configuration methods.
Step 1. Select external PC
Select external PC with quad core processor, 8 GB RAM, Windows 7 64-bit, recommended
Step 2. Select hardware for AXIe chassis
M9048A
PCIe desktop adaptor
Y1202A
2m PCIe cable
Step 3. Select hardware for PXIe chassis
M9048A
PCIe desktop adaptor
Y1202A
2m PCIe cable
M9021A
PCIe cable interface (installed in PXIe system slot)
2. For a list of qualified external controllers, please see Tested Computer List Technical Note, literature number 5990-7632EN. See physical connection diagram on page 10.
09 | Keysight | Multi-Channel Antenna Calibration Reference Solution - Configuration Guide
I. Select solution start-up kit and example software
Step 1. Choose solution level start-up kit and example software
Qty 1
Y1299A-003
Multi-channel antenna calibration, reference solution kit
Includes documentation and example software
J. Reference solution block diagram
10 | Keysight | Multi-Channel Antenna Calibration Reference Solution - Configuration Guide
K. Physical computer and PCIe connections
See multi-chassis configuration website for alternate configuration methods or if multiple PXIe chassis are required
www.keysight.com/find/pxie-multichassis
EMBEDDED CONTROLLER
EXTERNAL CONTROLLER
AXIe System 3
M9037A Embedded
Controller
Y1202A PCIe Cable
M9048A Desktop
Adapter
M9037A Embedded Controller, M9352A Amplifier,
M9362AD01 Downconverter installed in M9018A PXI
Chassis
Y1202A PCIe Cable
Y1202A PCIe Cable
M9048A Desktop Adapter
M9021A PCIe
Cable Interface 3
PXIe System 3
M9703A Digitizers installed in M9502A AXIe Chassis
3. An external controller may be used to connect to an AXIe or AXIe and PXIe chassis. If connecting to both, two M9048A desktop adapter modules and
Y1202A cables will be needed. Other configurations are possible. See www.keysight.com/find/pxie-multichassis for more information.
11 | Keysight | Multi-Channel Antenna Calibration Reference Solution - Configuration Guide
L. Select services
R-51B-001-C
Return to Keysight warranty - 1 year
Included with M9352A, M9048A
R-51B-001-3Z
Return to Keysight warranty - 3 years
R-51B-001-5Z
Return to Keysight warranty - 5 years
E8257D-UK6
Commercial calibration certificate with test data
Included with E8257D, M9018A, M9021A, M9037A, M9362AD01,
M9502A, M9505A, M9536A, M9703A, N5183B, N5193A
Available for E8257D, M9018A, M9021A, M9037A, M9362AD01, M9502A,
M9505A, M9536A, M9703A, N5183B, N5193A
Calibration certificate with measurement results available only at time of
purchase.
M9703A-UK6
Commercial calibration certificate with test data
Calibration certificate with measurement results available only at time of
purchase.
N5183B-UK6
Commercial calibration certificate with test data
Calibration certificate with measurement results available only at time of
purchase.
N5193A-UK6
Commercial calibration certificate with test data
Calibration certificate with measurement results available only at time of
purchase.
R-51B-001-3X
Express warranty - 5 day turnaround
For 3 years
Available for M9018A in the US, Japan, China and many EU countries
R-51B-001-5X
Express warranty - 5 day turnaround
For 5 years
Available for M9018A in the US, Japan, China and many EU countries
Global warranty
Calibration services
Keysight Technologies, Inc. provides the peace of mind that today’s
high tech industry requires. Your investment is protected by Keysight’s global reach in more than 100 countries (either directly or
through distributors). The warranty gives you convenient standard
coverage for the country in which the product is used, eliminating the need to ship equipment back to the country of purchase.
Keysight’s warranty service provides:
The modular products are factory calibrated and shipped with
an ISO-9002, NIST-traceable calibration certificate. A one year
calibration cycle is recommended.
–– All parts and labor necessary to return your investment to full
specified performance
–– Recalibration for products supplied originally with a
calibration certificate
–– Return shipment
Express warranty
Reduce downtime with the fastest repair service in the industry. The
express warranty upgrades the global warranty to provide:
–– 5 day typical turnaround repair service in the US, Japan,
China and many EU countries or up to a 10 day improvement
in turnaround time in the rest of the world
–– Priority return shipment
Product Information: www.keysight.com/find/contactus
Or call: 1 800 829-4444 US
Repair and Calibration: www.keysight.com/find/infoline
For all modular products: www.keysight.com/find/modular
12 | Keysight | Multi-Channel Antenna Calibration Reference Solution - Configuration Guide
M. Related literature
For more detailed product and specification information refer to the following literature and web pages:
–– Multi-Channel Antenna Calibration, Reference Solution Brochure (literature no. 5991-4537EN)
–– Tested Computer List Technical Note (literature no. 5990-7632EN)
–– Increase Multi-Antenna Array Test Throughput with the Keysight M9703A Digitizer Application Brief (literature no. 5991-1351EN)
–– How to Use the M9703A Digitizer-Based Solution to Perform Multi-Antenna Array Measurements Application Note (literature no.
5991-2543EN).
–– E8257D Microwave Analog Signal Generator Data Sheet (literature no. 5989-0698EN)
–– M9018A PXIe 18-Slot Chassis Data Sheet (literature no. 5990-6583EN)
–– M9037A PXIe High-Performance Embedded Controller Data Sheet (literature no. 5991-3661EN)
–– M9048A PCIe Desktop PC Adaptor Flyer (literature no. 5991-0356EN)
–– M9352A PXI Hybrid Amplifier/Attenuator Data Sheet (literature no. 5990-9964EN)
–– M9362AD01 PXI Quad Downconverter Data Sheet (literature no. 5990-9968EN)
–– M9502A/M9505A AXIe 2 and 5 Slot Chassis Data Sheet (literature no. 5990-6584EN)
–– M9514A AXIe 14 Slot Chassis Data Sheet (literature no. 5991-3980EN)
–– M9536A AXIe Embedded Controller Data Sheet (literature no. 5990-7756EN)
–– M9703A AXIe High-Speed Digitizer Data Sheet (literature no. 5990-8507EN)
–– N5183B Microwave Analog Signal Generator Data Sheet (literature no. 5991-3131EN)
–– N5193A Agile Signal Generator Brochure (literature no. 5992-0091EN)
13 | Keysight | Multi- Channel Antenna Calibration, Reference Solution - Configuration Guide
myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
www.pxisa.org
PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a
rugged, PC-based high-performance measurement and automation system.
www.axiestandard.org
AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an
open standard that extends the AdvancedTCA for general purpose and
semiconductor test. Keysight is a founding member of the AXIe consortium.
ATCA®, AdvancedTCA®, and the ATCA logo are registered US trademarks of
the PCI Industrial Computer Manufacturers Group.
www.lxistandard.org
LAN eXtensions for Instruments puts the power of Ethernet and the
Web inside your test systems. Keysight is a founding member of the LXI
consortium.
Keysight Assurance Plans
www.keysight.com/find/AssurancePlans
Up to five years of protection and no budgetary surprises to ensure your
instruments are operating to specification so you can rely on accurate
measurements.
www.keysight.com/quality
Keysight Technologies, Inc.
DEKRA Certified ISO 9001:2008
Quality Management System
Keysight Channel Partners
www.keysight.com/find/channelpartners
Get the best of both worlds: Keysight’s measurement expertise and product
breadth, combined with channel partner convenience.
For more information on Keysight
Technologies’ products, applications or
services, please contact your local Keysight
office. The complete list is available at:
www.keysight.com/find/contactus
Americas
Canada
Brazil
Mexico
United States
(877) 894 4414
55 11 3351 7010
001 800 254 2440
(800) 829 4444
Asia Pacific
Australia
China
Hong Kong
India
Japan
Korea
Malaysia
Singapore
Taiwan
Other AP Countries
1 800 629 485
800 810 0189
800 938 693
1 800 112 929
0120 (421) 345
080 769 0800
1 800 888 848
1 800 375 8100
0800 047 866
(65) 6375 8100
Europe & Middle East
Austria
Belgium
Finland
France
Germany
Ireland
Israel
Italy
Luxembourg
Netherlands
Russia
Spain
Sweden
Switzerland
PCI-SIG®, PCIe® and the PCI Express® are US registered trademarks and/or
service marks of PCI-SIG.
United Kingdom
www.keysight.com/find/modular
www.keysight.com/find/solution-mac
0800 001122
0800 58580
0800 523252
0805 980333
0800 6270999
1800 832700
1 809 343051
800 599100
+32 800 58580
0800 0233200
8800 5009286
0800 000154
0200 882255
0800 805353
Opt. 1 (DE)
Opt. 2 (FR)
Opt. 3 (IT)
0800 0260637
For other unlisted countries:
www.keysight.com/find/contactus
(BP-07-10-14)
This information is subject to change without notice.
© Keysight Technologies, 2014 - 2015
Published in USA, September 8, 2015
5991-4583EN
www.keysight.com