Global-Plus Product Description

Global-Plus Product Description
GLOBAL-PLUS
TYPE AEJHTK, AFJHTK
Effective 05-01-13
Supercedes 08-01-11
APPLICATIONS:
zPumps
z Fans & Blowers
zCompressors
FEATURES:
z 800 – 2,000 hp
z 3600, 1800, 1200, 900 RPM
z Totally Enclosed Fan Cooled (IP55)
z High Efficient Design
z 36 Month Warranty from Date of Manufacture
z 60 Hz, 2300/ 4160V
z Standard with 120V Space Heaters Terminated in Separate Auxiliary Box
z Standard with 100 Ohm Platinum Stator RTDs, 2 per Phase, Terminated in Separate Auxiliary Box
z 1.15 Service Factor – Continuous
z Class F with VPI Treatment of Solventless Epoxy Varnish Insulation
z Class B Temperature Rise
z NEMA Design B Torques
z Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrances F1 Mounted.
z Designed for 40˚C Ambient Temperature - Note (1)
z Designed for 3300 ft. Elevation - Note (2)
z Cast Iron Frame, End Brackets, and Conduit Box
z Rolled Steel Fan Cover
z 1045 Carbon Steel Shaft
z Copper/ Copper Alloy Rotor Construction
z Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat
z Paint Color: Blue Gray – Munsell 7.5BG 4/ 2
z Vacuum De-Gassed Re-Greasable Ball or Roller Bearings Using Polyrex EM Grease
z Insulated Non – Drive-End Bearing on 500 Frames and Larger
z Labyrinth Type Metal Grease Flinger on Both Ends
z Dust Flinger on Both Ends
z Cast Iron Inner and Outer Bearing Caps
z Grounding Terminal Inside Main Box and on Motor Foot
z Stainless Steel Nameplate
z Suitable for Use on a VFD 2:1 CT; 4:1 VT - Notes (3)(4)(5)(6)
z 6 Leads
z CSA Approved
z Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor
by the VFD as stated per NEMA MG1, Part 31.4.4.3.
EXTRAS/ OPTIONS:
Please refer to the modifications document on our web site for a list of common modifications that can be performed.
Notes:
* Win be discontinued soon and be replaced with AFHG Line.
(1) Please consult factory for suitability in higher ambients.
(2) Please consult factory for suitability in higher elevations.
(3) Service factor is 1.0 when motor is used on a VFD.
(4) An isolation transformer or other method of mitigating common mode voltages from motor terminals must be utilized.
(5) Please contact TWMC for variable and constant torque speed ranges.
(6)
Please refer to page 132 to check out our accompanying TeamMaster starters.
www.tecowestinghouse.com or call 1-800-USE-TECO
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement