Bettis Q -Series data sheet booklet

Bettis Q -Series data sheet booklet
Product data sheet
Sheet No.: BQ1.601.00 - Rev: 1
October 2015
Date:
Q-Series
Contents
Bettis Q-Series Valve Actuator 2
General Overview....................................................................................................... 2
Bettis Q-Series Actuator Torque 4
Double Acting Actuators.. - Nm & lbf.in ...................................................................... 4
Spring Return Actuators.. - Nm................................................................................... 5
Spring Return Actuators.. - lbf.in................................................................................. 6
Bettis Q-Series Valve Actuator Dimensions 7
Metric Actuators - ISO5211 / NAMUR plate................................................................ 7
Imperial Actuators - ISO5211 / NAMUR plate............................................................. 8
Metric Actuators - DIN3337 / NAMUR plate............................................................... 9
Metric Actuators - ISO5211....................................................................................... 10
Imperial Actuators - ISO5211.................................................................................... 11
Metric Actuators - DIN3337...................................................................................... 12
Bettis Q-Series Valve Actuator Options
13
Drive Inserts............................................................................................................. 13
Position Indication - Center Plate............................................................................. 14
NAMUR Plate........................................................................................................... 15
Integrated XP Control Modules 16
QC41, QC42 and QC43 (Ex d / XP)......................................................................... 16
Pneumatic Controls..................................................................................................18
Position feedback..................................................................................................... 20
Control Module Option............................................................................................. 23
Hazardous area specifications................................................................................. 24
Corrosion protection Bettis Q-Series........................................................................ 25
Control Module Configuration................................................................................... 26
Integrated Control modules
27
QC54........................................................................................................................ 27
Pneumatic Control.................................................................................................... 30
Switch Point Setting................................................................................................. 32
Control Module Options............................................................................................ 33
Wiring and Quick Connectors................................................................................... 34
Diagnostics and PlantWeb Alerts............................................................................. 35
Control Module Configuration................................................................................... 37
Miscellaneous Information
38
Parts and Materials Actuator and Modules............................................................... 38
Failure modes........................................................................................................... 40
Double acting assembly codes................................................................................. 41
Single acting (Spring Return) assembly codes........................................................ 42
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.601.01 - Rev: 0, page 1 of 2
Date:
May 2014
Q-Series
Bettis Q-Series "fully integrated" actuator
and control modules
General Overview
Description
The Bettis Q-Series package consists of an actuator with
a module for control and position feed back and forms an
integrated concept for “On/Off” valve automation.
Bettis Q-Series valve actuator with Control Module
3
6
1 Basic actuators
The basic actuator supplies the torque, required to open
and close valves and is available in various sizes (rated
47 to 1676Nm at 5.5barg or 413 to 14874 In.lb. at 80pisg).
Double acting and spring return executions are available.
The spring return execution can be equipped with multiple
spring sets to cover a pressure range from 2 to 8 barg (30
to 120 psig).
2 Control Modules
The Control Modules contain the terminal connections for
control and feedback signals, the pilot valve for directly
controlling the Pneumatic Module and indirectly controlling
the basic actuator. Three ranges of control modules are
available: The Control Modules contain the electric and
pneumatic components required to operate the actuator
to the open or closed position and generate and the end
positions a position feedback signal.
The module is available as Weather proof or Explosion
proof.
1.The enclosure is rated IP66 / NEMA 4X according IEC 60529 and is suitable for indoor and outdoor use.
2.The Explosion proof control modules are suitable for use
in potentially explosive atmospheres and comply with the
Explosion proof (XP) or Flame proof (Ex d) protection
methods as required by FM, CSA, ATEX or IECEx.
3.Both the Weather Proof and Explosion proof control
modules are available with the Fail-In-Last-Position
control function for double acting actuators and the non
intrusive switch point adjustment.
1
5
4
2
8
1 Basic Actuator
2 Control Module
3 Limit stop screws for
“Open” and “Closed”
position
4 G1/4” air connections
5 Optional: Built-in speed
control
6 Visual position indication
7 Optional: Manual Control
8 Electrical entries
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
7
Product data sheet
Sheet No.: BQ1.601.01 - Rev: 0, page 2 of 2
Date:
May 2014
Q-Series
Actuator specifications:
Construction
- Ingress protection rated IP65 / NEMA4X and suitable for
indoor and outdoor installation.
Finish
- Housing:
- Pistons:
- Pinion:
Anodized with a polyurethan powder coating
Chromate treatment.
Hard anodized
Lubrication
- Factory lubricated for the normal life of the actuator.
Temperature
- Depends on the Control Module used. See applicable data
sheets BQ1.604.xxx.
European Directives
- The basic actuator complies to PED 97/23/EC, Machinery
Directive 2006/42/EC and to ATEX 94/9/EC and is marked:
II 2 GD c IIC TX
Pressure
- Double acting:
2 to 8 bar / 30 to 120 psi
- Spring return - with maximum spring set: 6 to 8 bar / 87 to 120 psi
- with reduced spring set: 3 to 8 bar / 43 to 120 psi
Operating media
- Dry air or inert gasses, filtered to 50 microns.
- Dew point 10K below operating temperature. For subzero
applications take appropriate measures to protect the
installation.
Torque
- 40 to 1600 Nm. (300 to 11000 lbf.in ) See sheets
BQ1.602.01, BQ1.602.02 or BQ1.602.03.
Rotation
- Factory set at 90°±0.5°. Adjustable range: -3° to +15° and
+75° to 93°
- Clockwise fail-to-close action, see sheet BQ1.606.04 for
optional fail-to-open action (assembly codes).
- See BQ1.606.03 for other double acting assembly codes.
- For more info on failure modes see BQ1.606.02
+15°
-3°
Actuator data
Bore
Stroke
90°±0.5
+75°
+93°
Q-Series Valve Actuator:
Rotation and adjustable
range
Weight:
Double acting
Spring return
Cycle life
- 500.000 cycles minimum
NAMUR plate
The top flange of the Bettis Q-Series actuator is equipped
with a NAMUR (VDE/VDI 3845) drilling pattern.
The addition of a NAMUR plate makes the Bettis Q-Series
actuator suitable for mounting all kinds of NAMUR compatible
control accessories like solenoids. For more info on NAMUR
plate, see sheet BQ1.605.03.
Control Modules:
The following versions of Control modules are available.
Please check the indicated data sheet for more detailed
information.
- QC41 24VDC BQBQ1.604.10
- QC42 115VAC BQBQ1.604.10
- QC43 230VAC BQBQ1.604.10
Options
Manual Control, IECEx, ATEX, FM or CSA approvals, glands,
plugs and connector plugs.
Functions:
Double or Single Acting (spring return)
Fail-in-Last position
Actuator range:
Suitable for Q40 to Q1600 (see note below).
Enclosure :
IP66 / NEMA4X
Pneumatic connections:
G1/4”
“Breather” function:
Standard for single acting actuators
Options :
Speed control, exhaust port filters or silencers.
mm.
inch
mm.
inch
kg.
lb.
kg.
lb.
sec.
Operating time
Air consumption per stroke
at 1 atm (litres)
Central air chamber
Endcap air chambers
at 1 atm (cu. in.)
Central air chamber
Endcap air chambers
Q40
70
2,76
18,8
0,74
1,8
4,0
2,4
5,3
0,7
Q65
80
3,15
22,0
0,87
2,4
5,3
3,6
7,9
1,1
Q100
91
3,58
25,1
0,99
3,1
6,8
4,6
10
1,2
Q150
103
4,06
31,4
1,24
4,5
9,8
6,9
15,1
1,8
Q200
110
4,33
37,7
1,48
5,8
13
9,1
20
2,3
Q350
145
5,71
37,7
1,48
10,4
23
17
37
3,6
Q600
175
6,89
44,0
1,73
19
43
28
61
4,5
0,16
0,22
10
13
0,33
0,36
20
22
0,35
0,49
21
30
0,84
0,78
51
48
0,8
1
49
61
1,8
1,9
110
116
2,9
3,1
177
189
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Q950 Q1600
200
230
7,87
9,06
50,3
62,8
1,98
2,47
26
43
58
94
39
66
85
145
5,4
6,9
4,7
4,9
287
299
7,3
8,0
445
488
Product data sheet
Sheet No.: BQ1.602.01 - Rev: 1
April 2015
Date:
Q-Series
Bettis Q-Series Actuator Torque
Double Acting Actuators
Actuator
type
QD
QD
QD
QD
QD
QD
QD
QD
QD
40
65
100
150
200
350
600
950
1600
Actuator
type
QD
QD
QD
QD
QD
QD
QD
QD
QD
40
65
100
150
200
350
600
950
1600
2
17
25
38
60
82
143
243
363
600
30
153
233
344
551
754
1310
2226
3323
5493
3
25
38
57
91
124
216
368
549
907
45
231
352
520
833
1140
1981
3366
5025
8307
3.5
29
45
66
106
146
253
430
642
1061
50
257
391
579
927
1269
2205
3747
5593
9245
- Nm
4
34
51
76
122
167
290
492
735
1214
Torque (Nm)
Supply Pressure (bar g)
4.5
5
5.5
38
42
47
58
64
71
86
95
105
137
153
168
188
209
230
326
363
400
554
617
679
828
921
1014
1368
1522
1676
6
51
77
115
183
251
436
741
1107
1829
6.5
55
84
124
199
272
473
804
1200
1983
7
59
90
134
214
293
510
866
1293
2137
8
68
104
153
245
335
583
991
1479
2444
60
309
471
696
1115
1526
2652
4507
6727
11121
Torque (lbf.in)
Supply pressure (psig)
65
70
75
335
361
387
511
550
590
755
814
873
1209
1303
1397
1655
1784
1913
2876
3100
3323
4887
5267
5647
7295
7862
8430
12059
12998
13936
80
413
630
931
1491
2041
3547
6028
8997
14874
90
465
709
1049
1680
2299
3994
6788
10132
16750
100
518
789
1166
1868
2556
4442
7548
11267
18626
120
622
948
1401
2244
3071
5337
9069
13537
22379
Double acting torque diagram
START
START
END
TORQUE
END
ROTATION
Note:
1.Emerson Process Management recommends that the valve manufacturer supply the maximum required torque values
(Including any adjustments or suggested safety factors for valve service conditions or application). Additionally, the valve
manufacturer must identify at which position(s) and direction(s) of rotation (Counter Clock Wise or Clock Wise) these
maximum requirements occur.
2.If in doubt, or you require any assistance with sizing actuators, do not hesitate to contact your nearest Emerson’s
Valve Automation representative.
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.602.02 - Rev: 0
May 2014
Date:
Q-Series
Bettis Q-Series Actuator Torque
Spring Return Actuators
Spring set
nr.
Actuator
Size
QS 40
2
3
4
5
6
QS65
2
3
4
5
6
QS 100
2
3
4
5
6
QS 150
2
3
4
5
6
QS 200
2
3
4
5
6
QS 350
2
3
4
5
6
QS 600
2
3
4
5
6
QS 950
2
3
4
5
6
QS 1600 2
3
4
5
6
C
17
12
26
18
39
29
63
46
85
61
144
101
249
179
375
272
617
445
-
3
D
11
4
17
4
27
10
41
14
57
19
96
30
166
54
248
82
416
144
-
3.5
C
D
22
16
17
8
12
1
32
23
25
11
49
37
39
20
28
3
79
58
62
30
107 79
84
41
60
4
183 135
140 68
97
2
315 232
245 120
174
8
474 347
371 181
268 14
780 579
608 307
436 35
-
- Nm
Air Torque (Nm)
Supply pressure (bar g)
4
4.5
5
5.5
C
D
C
D
C
D
C
D
26
21
31
25
35
30
40
34
21
13
26
17
31
22
35
27
17
5
21
10
26
14
30
19
17
2
21
7
26
11
21
4
39
30
46
37
53
44
60
51
32
18
39
25
45
32
52
39
24
6
31
13
38
20
45
27
23
1
30
8
37
15
30
3
60
47
70
57
80
67
90
78
49
30
59
40
70
51
80
61
39
13
49
24
59
34
69
44
38
7
49
17
59
27
38
0
48
11
95
74 112 90 128 107 144 123
79
47
95
63 111 79 128 96
62
19
78
36
94
52 111 68
78
24
94
41
130 101 152 124 174 146 197 168
106 64 129 86 151 109 173 131
83
26 105 49 127 71 150 93
82
11 104 33 126 56
103 18
221 174 260 213 299 251 338 290
179 107 217 146 256 185 295 224
136 41 175 80 214 118 252 157
132 13 171 52 210 91
167 24
381 298 447 364 513 430 579 496
311 186 377 252 443 318 509 384
240 74 306 140 372 206 438 272
236 28 302 94 368 160
298 48
572 446 671 544 769 643 868 741
469 279 568 378 666 476 765 575
366 113 465 211 563 310 662 408
362 45 460 143 559 242
455 75
943 742 1106 905 1269 1068 1432 1231
771 470 934 633 1097 796 1260 959
599 198 762 361 925 523 1088 686
590 88 753 251 916 414
744 142
6
C
D
44
39
40
31
35
23
30
16
25
8
67
58
59
46
52
34
44
22
36
10
100 88
90
71
79
54
69
38
59
21
161 139
144 112
127 85
110 57
94
30
219 191
196 153
172 116
149 78
125 41
377 329
334 263
291 196
248 130
206 63
645 562
575 450
504 338
434 226
364 114
966 840
863 673
760 507
657 340
554 174
1594 1394
1423 1121
1251 849
1079 577
907 305
7
C
D
53
48
49
40
44
32
39
25
34
17
81
72
73
60
65
48
58
35
50
23
121 108
110 91
100 75
89
58
79
41
193 172
177 145
160 117
143 90
126 62
264 236
240 198
217 160
193 123
170 85
454 407
412 340
369 274
326 207
283 141
777 694
707 582
636 470
566 358
496 246
1163 1037
1060 870
957 704
854 537
751 371
1920 1719
1748 1447
1576 1175
1405 903
1233 630
Spring
Torque
(Nm)
E
F
13
8
20
12
26
17
33
21
40
25
21
13
32
20
42
26
53
33
63
40
29
18
44
27
58
36
73
46
88
55
48
29
72
44
95
58
119 73
143 88
65
41
98
61
131 82
163 102
196 123
116 74
174 112
232 149
289 186
347 223
195 122
292 183
389 245
487 306
584 367
290 179
434 269
579 359
724 448
869 538
474 299
711 449
947 598
1184 748
1421 897
Spring return
torque diagrams
C=
Start
Air stroke
D=
End
Torque
Rotation Counter
Clockwise
E=
Start
Spring stroke
F=
End
Torque
Rotation Clockwise
Note:
1.Emerson Process Management recommends that the valve manufacturer supply the maximum required torque values
(Including any adjustments or suggested safety factors for valve service conditions or application).
Additionally, the valve manufacturer must identify at which position(s) and direction(s) of rotation (Counter Clock Wise or
Clock Wise) these maximum requirements occur.
2.If in doubt, or you require any assistance with sizing actuators, do not hesitate to contact your nearest Emerson’s
Valve Automation representative.
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.602.03 - Rev: 0
April 2015
Date:
Q-Series
Bettis Q-Series Actuator Torque
Spring Return Actuators
Spring set
nr.
Actuator
Size
QS 40
2
3
4
5
6
QS 65
2
3
4
5
6
QS 100
2
3
4
5
6
QS 150
2
3
4
5
6
QS 200
2
3
4
5
6
QS 350
2
3
4
5
6
QS 600
2
3
4
5
6
QS 950
2
3
4
5
6
QS 1600 2
3
4
5
6
C
133
196
303
211
485
656
1105
1920
2898
4765
-
40
D
82
117
192
44
297
406
684
1183
1777
2988
-
C
243
201
159
364
297
230
552
460
367
884
735
587
1201
994
786
2053
1675
1297
3531
2909
2287
5303
4391
3479
8741
7220
5699
-
60
D
193
125
58
285
178
71
441
293
144
696
453
210
952
619
287
1632
1043
454
2794
1804
814
4182
2709
1236
6964
4554
2144
-
- lbf.in
Air Torque (lbf.in)
Supply pressure (psig)
80
90
C
D
C
D
354
303
409
358
312
236
367
291
270
169
325
224
227
101
283
156
241
89
533
454
617
538
466
347
550
431
398
240
482
324
331
133
415
217
348
110
801
690
926
814
709
541
833
666
616
393
740
518
523
245
648
369
430
96
555
221
1283 1094 1482 1294
1134
852 1333 1051
985
609
1185
808
837
366 1036 565
887
322
1747 1497 2020 1770
1539 1165 1812 1438
1332 832 1604 1105
1124
500 1396 772
1189
440
3001 2580 3475 3054
2623 1991 3097 2465
2245 1402 2719 1877
1866 814 2340 1288
1962 699
5142 4405 5947 5211
4520 3415 5325 4221
3898 2425 4703 3230
3276 1434 4081 2240
3459 1250
7708 6587 8910 7789
6796 5114 7998 6316
5883 3641 7086 4844
4971 2168 6174 3371
5262 1898
12716 10939 14704 12927
11195 8530 13183 10517
9675 6120 11662 8108
8154 3711 10141 5698
8621 3289
100
C
D
464
414
422
346
380
279
338
212
296
144
701
622
634
515
567
408
499
301
432
194
1050 939
957
790
865
642
772
494
679
345
1681 1493
1533 1250
1384 1007
1235 764
1087 522
2293 2043
2085 1710
1877 1378
1669 1045
1462 713
3949 3528
3571 2939
3193 2351
2814 1762
2436 1173
6753 6016
6131 5026
5509 4036
4887 3046
4265 2055
10113 8992
9201 7519
8288 6046
7376 4573
6464 3100
16692 14915
15171 12505
13650 10096
12129 7686
10608 5277
120
C
D
575
524
533
457
491
390
448
322
406
255
870
790
802
683
735
576
668
470
601
363
1299 1188
1206 1039
1114
891
1021 743
928
594
2080 1892
1931 1649
1783 1406
1634 1163
1485 920
2838 2589
2631 2256
2423 1923
2215 1591
2007 1258
4897 4476
4519 3887
4141 3299
3762 2710
3384 2121
8364 7628
7742 6637
7120 5647
6498 4657
5876 3666
12518 11396
11606 9924
10693 8451
9781 6978
8869 5505
20668 18890
19147 16481
17626 14071
16105 11662
14584 9252
Spring
Torque
(lbf.in)
E
F
117
73
176
110
234
146
293
183
351
220
186
117
279
176
372
234
465
292
558
351
258
161
387
242
516
323
646
403
775
484
423
259
634
388
845
517
1056 647
1268 776
579
362
868
542
1158
723
1447 904
1736 1085
1025 658
1537 987
2049 1317
2561 1646
3074 1975
1723 1082
2585 1624
3446 2165
4308 2706
5169 3247
2563 1587
3844 2381
5125 3175
6407 3968
7688 4762
4193 2646
6289 3970
8385 5293
10481 6616
12578 7939
Spring return
torque diagrams
C=
Start
Air stroke
D=
End
Torque
Rotation Counter
Clockwise
E=
Start
Spring stroke
F=
End
Torque
Rotation Clockwise
Note:
1.Emerson Process Management recommends that the valve manufacturer supply the maximum required torque values
(Including any adjustments or suggested safety factors for valve service conditions or application).
Additionally, the valve manufacturer must identify at which position(s) and direction(s) of rotation (Counter Clock Wise or
Clock Wise) these maximum requirements occur.
2.If in doubt, or you require any assistance with sizing actuators, do not hesitate to contact your nearest Emerson’s
Valve Automation representative.
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.603.05 - Rev: 0
May 2014
Date:
Q-Series
Bettis Q-Series Valve Actuator Dimensions
Metric Actuators - ISO5211 / NAMUR plate
M6x12
M5x8
T
E
30
F
2x 1/4"BSP
4
4
90
G
32
D
M5x8
D
4
24
60
P2
P1
C'
C
H
A (QD)
B (QS)
W1
O
P
+0.5
-0
R
S
280
234.6
92.7
K
I
W
V
±0.5
M1 M2
J
V1
N
132
M16
x 25
Note:
1.Dimensions are in mm.
2.The limit stop screws on the Q40 and Q65
are on the opposite side to those on the
larger actuators.
Dim
Bettis Q-Series actuator models
in mm.
Q40
Q65
Q100
Q150
Q200
Q 350
Q600
Q950
Q1600
A QD
145
168
181
217
242
262
327
366
447
B QS
202
249
254
311
358
391
419
460
568
C
104
117
141
150
161
191
245
276
337
C’
137
150
175
184
194
225
289
319
380
D
20
20
20
20
20
20
30
30
30
E
56
56
56
65
66
66
84
88
95
F
16
18
18
22
30
30
35
35
45
G
9,5
9
11
10
9
10
19,5
19
28,5
H
90
102
115
129
135
177
209
234
268
I
75
81
88
97
99
119
134
147
164
J
40
40
34
46
45
46
53
40
70
K
33
33
38
55
55
55
68
75
95
M1
34.5
34.5
34.5
50
50
50
52
64
82
M2
27
37
37
N
1
1
1.5
1.0
1.5
1.5
1.5
1.5
1.5
O max. 14.11
14.11
19.13
19.13
22.13
27.13
27.13
36.16
46.16
O min.
14.00
14.00
19.00
19.00
22.00
27.00
27.00
36.00
46.00
P
18.1
18.1
25.2
25.2
28.2
36.2
36.2
48.2
60.2
P1
18.1
18.1
23.1
28.5
32.1
32.1
36.5
48.5
60.5
P2
25.2
36.2
36.2
R
65
70
70
90
90
114
124
130
154
S
65
70
70
90
90
114
124
142
280
T
80
80
80
80
80
80
130
130
130
PCD F05/F07 F05/F07 F05/F07 F07/F10 F07/F10 F07/F10 F10/F12 F10/F14 F16/F25*
V
50
50
50
70
70
70
102
102
165
V1
70
70
70
102
102
102
125
140
M6x
M6x
M6x
M8x
M8x
M8x
M10x
M10x
M20x
W
10
10
10
13
13
13
16
16
30
M8x
M8x
M8x
M10x
M10x
M10x
M12x
M16x
W1
13
13
13
16
16
16
20
25
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.603.06 - Rev: 0
April 2015
Date:
Q-Series
Bettis Q-Series Valve Actuator Dimensions
Imperial Actuators - ISO5211 / NAMUR plate
M6x0.47"
10-24x0.31"
T
E
1.18"
F
0.16"
0.16"
G
2x 1/4"NPT
D
3.56" 1.26"
10-24x0.31"
0.94"
2.36"
D
0.16"
P2
P1
C'
C
H
A (QD)
B (QS)
W1
O R
P
+0.02"
S
11.02"
9.23"
3.82"
K
I
W
V
±0.02
M1 M2
J
V1
N
5.19"
5/8"-11
x.98
Note:
1.Dimensions are in inches.
2.The limit stop screws on the Q40 and
Q65 are on the opposite side to those on
the larger actuators.
Dim. in
Bettis Q-Series actuator models
inches
Q40
Q65
Q100
Q150
Q200
Q350
Q600
Q950
Q1600
A QD
5.71
6.61
7.13
8.54
9.54
10.31
12.87
14.40
17.58
B QS
7.94
9.79
9.99
12.24
14.09
15.38
16.50
18.09
22.34
C
4.09
4.59
5.55
5.91
6.34
7.52
9.65
10.87
13.27
C’
5.39
5.92
6.89
7.24
7.64
8.86
11.38
12.56
14.96
D
0.79
0.79
0.79
0.79
0.79
0.79
1.18
1.18
1.18
E
2.20
2.20
2.20
2.56
2.60
2.60
3.31
3.46
3.74
F
0.63
0.71
0.71
0.87
1.18
1.18
1.38
1.38
1.77
G
0.37
0.35
0.43
0.39
0.35
0.39
0.77
0.75
1.12
H
3.54
4.02
4.53
5.08
5.31
6.97
8.23
9.21
10.55
I
2.95
3.19
3.46
3.82
3.90
4.69
5.28
5.79
6.46
J
1.56
1.56
1.32
1.81
1.78
1.81
2.08
1.58
2.75
K
1.30
1.30
1.50
2.17
2.17
2.17
2.68
2.95
3.74
M1
1.36
1.36
1.36
1.97
1.97
1.97
2.05
2.52
3.23
M2
1.06
1.46
1.46
N
0.04
0.04
0.06
0.04
0.06
0.06
0.06
0.06
0.06
O max. 0.556
0.556
0.753
0.753
0.871
1.068
1.068
1.424
1.817
O min.
0.551
0.551
0.748
0.748
0.866
1.063
1.063
1.417
1.811
P
0.71
0.71
0.99
0.99
1.11
1.43
1.43
1.90
2.37
P1
0.71
0.71
0.91
1.12
1.26
1.26
1.44
1.91
2.38
P2
0.99
1.43
1.43
R
2.56
2.76
2.76
3.54
3.54
4.49
4.88
5.12
6.06
S
2.56
2.76
2.76
3.54
3.54
4.49
4.88
5.59
11.02
T
3.15
3.15
3.15
3.15
3.15
3.15
5.12
5.12
5.12
PCD F05/F07 F05/F07 F05/F07 F07/F10 F07/F10 F07/F10 F10/F12 F10/F14 F16/F25*
V
1.969
1.969
1.969
2.756
2.756
2.756
4.016
4.016
6.496
V1
2.756
2.756
2.756
4.016
4.016
4.016
4.921
5.512
1/4”1/4”1/4”5/16”5/16”5/16”3/8”3/8”3/4”W
20x.39 20x.39 20x.39 18x.39 18x.39 18x.39 16x.63 16x.63 10x1.14
5/16”5/16”5/16”3/8”3/8”3/8”1/2”5/8”W1
18x.39 18x.39 18x.39 16x.63 16x.63 16x.63 13x.79 11x.98
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.603.07 - Rev: 0
May 2014
Date:
Q-Series
Bettis Q-Series Valve Actuator Dimensions
Metric Actuators - DIN3337 / NAMUR plate
E
M6x12
F
M5x8
T
30
2x 1/4"BSP
4
4
32
G
D
M5x8
D
4
24
60
P2
P1
C'
C
M1 M2
J
H
A (QD)
B (QS)
V
W
P
+0.5
-0
R
S
280
234.6
M16
x25
Max. 5
I
O
97.2
N ±0.5
132
Dim
in mm.
A QD
B QS
C
C’
D
E
F
G
H
I
J
K
K1
M1
M2
N
O max.
O min.
P
P1
P2
Q
R
S
T
PCD
V
W
K1’
Q’
PCD
V’
W’
Q40
145
202
104
137
20
56
16
9,5
86
128
40
33
32
34.5
1
14.11
14.00
18.1
18.1
35
65
65
80
F05
50
M6x
10
Q65
168
249
116,5
150,4
20
56
18
14
102
141,8
40
33
32
34.5
1
14.11
14.00
18.1
18.1
70
70
80
50
F05
50
M6x
10
Q100
181
254
141
175
20
56
18
11
108
141
34
38
40
34.5
27
1.5
17.13
17.00
22.2
23.1
25.2
55
70
70
80
F07
70
M8x
13
40
55
F07
70
M8x
13
40
35
F07
70
M8x
13
32
35
F05
50
M6x
10
øK
øK1
Bettis Q-Series actuator models
Q150
Q200
Q350
Q600
217
242
262
327
311
358
391
419
150
161
191
245
184
194
225
289
20
20
20
30
65
66
66
84
22
30
30
35
10
9
10
19,5
129
128
173
207
97
149
171
187
46
45
46
53
55
55
55
68
50
54
54
68
50
50
50
52
37
37
1
1.5
1.5
1.5
17.13
22.13
22.13
27.13
17.00
22.00
22.00
27.00
22.2
28.2
28.2
36.2
28.5
32.1
32.1
36.5
36.2
36.2
55
70
70
85
90
90
114
124
90
90
114
124
80
80
80
130
F07
F10
F10
F12
70
102
102
125
M8x
M10x
M10x
M12x
13
16
16
20
Optional dimensions
54
50
50
70
55
55
F10
F07
F07
F10
102
70
70
102
M10x
M8x
M8x
M10x
16
13
13
16
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Q950
366
460
276
319
30
88
35
19
231
200
40
75
75
64
1.5
36.16
36.00
48.2
48.5
100
130
142
130
F14
140
M16x
25
Q1600
447
568
337
380
30
95
45
28,5
265
217
70
95
95
82
1.5
46.16
46.00
60.2
60.5
130
154
280
130
F16
165
M20x
30
F10
102
M10x
16
F25*
-
Product data sheet
Sheet No.: BQ1.603.08 - Rev: 0
May 2014
Date:
Q-Series
Bettis Q-Series Valve Actuator Dimensions
Metric Actuators - ISO5211
T
M5x8
4
D
G1/4"
30
C'
C
H
144
A (QD)
B (QS)
limit stops on Q40 & Q65
Pinion drive
details
Note:
1.Dimensions are metric (mm).
2.The limit stop screws on the Q40 and Q65 are on the opposite side to those
on the larger actuators.
3.Top flange according VDI/VDE 3845 (NAMUR)
P2
P1
N±0.5
M1 M2
K
W
V1
V
Flange for
W1 Q40 - Q950
O
P +0.5
-0
280
97.2
M16
x25
R
S
234.6
I
Flange for
Q1600
132
*) Four holes of the F25
ISO Drilling pattern
Dim
Bettis Q-Series actuator models
Q40
Q65
Q100
Q150
Q200
Q350
Q600
Q950
Q1600
in mm.
A QD
180
199
221
254
283
305
387
424
516
B QS
204
249
267
310
346
387
416
460
568
C
104
117
141
150
161
191
245
276
337
C’
137
150
175
184
194
225
289
319
380
D
20
20
20
20
20
20
30
30
30
E
56
56
56
65
66
66
84
88
95
F
16
18
18
22
30
30
35
35
45
G
9,5
9
11
10
9
10
19,5
19
28,5
H
90
102
115
129
135
177
209
234
268
I
212
218
225
232
235
256
272
284
301
J
40
40
34
46
45
46
53
40
70
K
33
33
38
55
55
55
68
75
95
M1
34.5
34.5
34.5
50
50
50
52
64
82
M2
27
37
37
N
1
1
1.5
1.0
1.5
1.5
1.5
1.5
1.5
O max. 14.11
14.11
19.13
19.13
22.13
27.13
27.13
36.16
46.16
O min.
14.00
14.00
19.00
19.00
22.00
27.00
27.00
36.00
46.00
P
18.1
18.1
25.2
25.2
28.2
36.2
36.2
48.2
60.2
P1
18.1
18.1
23.1
28.5
32.1
32.1
36.5
48.5
60.5
P2
25.2
36.2
36.2
R
65
70
70
90
90
114
124
130
154
S
65
70
70
90
90
114
124
142
280
T
80
80
80
80
80
80
130
130
130
PCD F05/F07 F05/F07 F05/F07 F07/F10 F07/F10 F07/F10 F10/F12 F10/F14 F16/F25*
V
50
50
50
70
70
70
102
102
165
V1
70
70
70
102
102
102
125
140
W
M6x10 M6x10 M6x10 M8x13 M8x13 M8x13 M10x16 M10x16 M20x30
W1
M8x13 M8x13 M8x13 M10x16 M10x16 M10x16 M12x20 M16x25
-
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.603.09 - Rev: 0
April 2015
Date:
Q-Series
Bettis Q-Series Valve Actuator Dimensions
Imperial Actuators - ISO5211
T
10-24x .31
0.16
D
1/4” NPT
1.18
C'
C
H
5.65”
A (QD)
I
B (QS)
limit stops on Q40 & Q65
Note:
1.Dimensions are in inches.
2.The limit stop screws on the Q40 and Q65 are on the opposite side to those
on the larger actuators.
3.Top flange according VDI/VDE 3845 (NAMUR)
Pinion drive
details
P2
P1
N±0.02
M1 M2
K
W
V1
V
Flange for
W1 Q40 - Q950
O
P +0.02
-0
S
11.02
9.23
3.83
5/8"11x.98
R
Flange for
Q1600
5.20
*) Four holes of the F25
ISO Drilling pattern
Bettis Q-Series actuator models
Dim in
inches
Q40
Q65
Q100
Q150
Q200
Q350
Q600
Q950
Q1600
A QD
7.09
7.83
8.70
10.00
11.14
12.01
15.24
16.69
20.31
B QS
8.03
9.80
10.51
12.20
13.62
15.24
16.38
18.09
22.34
C
4.09
4.59
5.55
5.91
6.34
7.52
9.65
10.87
13.27
C’
5.39
5.92
6.89
7.24
7.64
8.86
11.38
12.56
14.96
D
0.79
0.79
0.79
0.79
0.79
0.79
1.18
1.18
1.18
E
2.20
2.20
2.20
2.56
2.60
2.60
3.31
3.46
3.74
F
0.63
0.71
0.71
0.87
1.18
1.18
1.38
1.38
1.77
G
0.37
0.35
0.43
0.39
0.35
0.39
0.77
0.75
1.12
H
3.54
4.02
4.53
5.08
5.31
6.97
8.23
9.21
10.55
I
8.65
8.9
9.16
9.45
9.57
10.43
11.08
11.59
12.29
J
1.56
1.56
1.32
1.81
1.78
1.81
2.08
1.58
2.75
K
1.30
1.30
1.50
2.17
2.17
2.17
2.68
2.95
3.74
M1
1.36
1.36
1.36
1.97
1.97
1.97
2.05
2.52
3.23
M2
1.06
1.46
1.46
N
0.04
0.04
0.06
0.04
0.06
0.06
0.06
0.06
0.06
O max. 0.556
0.556
0.753
0.753
0.871
1.068
1.068
1.424
1.817
O min.
0.551
0.551
0.748
0.748
0.866
1.063
1.063
1.417
1.811
P
0.71
0.71
0.99
0.99
1.11
1.43
1.43
1.90
2.37
P1
0.71
0.71
0.91
1.12
1.26
1.26
1.44
1.91
2.38
P2
0.99
1.43
1.43
R
2.56
2.76
2.76
3.54
3.54
4.49
4.88
5.12
6.06
S
2.56
2.76
2.76
3.54
3.54
4.49
4.88
5.59
11.02
T
3.15
3.15
3.15
3.15
3.15
3.15
5.12
5.12
5.12
PCD F05/F07 F05/F07 F05/F07 F07/F10 F07/F10 F07/F10 F10/F12 F10/F14 F16/F25*
V
1.969
1.969
1.969
2.756
2.756
2.756
4.016
4.016
6.496
V1
2.756
2.756
2.756
4.016
4.016
4.016
4.921
5.512
1/4”1/4”1/4”5/16”5/16”5/16”3/8”3/8”3/4”W
20x.39 20x.39 20x.39 18x.39 18x.39 18x.39 16x.63 16x.63 10x1.14
5/16”5/16”5/16”3/8”3/8”3/8”1/2”5/8”W1
18x.39 18x.39 18x.39 16x.63 16x.63 16x.63 13x.79 11x.98
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.603.10 - Rev: 0
Date:
May 2014
Q-Series
Bettis Q-Series Valve Actuator Dimensions
Metric Actuators - DIN3337
T
M5x8
4
D
G1/4"
30
C'
C
H
144
I
A (QD)
B (QS)
limit stops on Q40 & Q65
P2
P1
Note:
1.Dimensions are metric (mm).
2.The limit stop screws on the Q40 and Q65 are on the opposite side to those
on the larger actuators.
Pinion drive details 3.Top flange according VDI/VDE 3845 (NAMUR)
and center plate
Dim
Bettis Q-Series actuator models
Q40
Q65
Q100
Q150
Q200
Q350
Q600
Q950
Q1600
in mm.
dimensions
N
±0.5
M1 M2
Max. 5
øK
øK1
V
W
O
P
+0.5
-0
Flange for
Q40 - Q950
R
S
280
234.6
97.2
M16
x25
Flange for
Q1600
132
*) Four holes of the F25
Drilling pattern
A QD
B QS
C
C’
D
E
F
G
H
I
J
K
K1
M1
M2
N
O max.
O min.
P
P1
P2
Q
R
S
T
PCD
V
W
180
204
104
137
20
56
16
9,5
86
212
40
33
32
34,5
1
14,11
14,00
18,1
18,1
35
65
65
80
F05
50
M6x10
199
249
116,5
150,4
20
56
18
14
102
218
40
33
32
34,5
1
14,11
14,00
18,1
18,1
70
70
80
50
F05
50
M6x10
K1’
Q’
PCD
V’
W’
40
55
F07
70
M8x13
40
35
F07
70
M8x13
221
267
141
175
20
56
18
11
108
225
34
38
40
34,5
27
1,5
17,13
17,00
22,2
23,1
25,2
55
70
70
80
F07
70
M8x13
254
283
305
387
424
310
360
387
477
517
150
161
191
245
276
184
194
225
289
319
20
20
20
30
30
65
66
66
84
88
22
30
30
35
35
10
9
10
19,5
19
129
128
173
207
231
232
235
256
272
284
46
45
46
53
40
55
55
55
68
75
50
54
54
68
75
50
50
50
52
64
37
37
1
1,5
1,5
1,5
1,5
17,13
22,13
22,13
27,13
36,16
17,00
22,00
22,00
27,00
36,00
22,2
28,2
28,2
36,2
48,2
28,5
32,1
32,1
36,5
48,5
36,2
36,2
55
70
70
85
100
90
90
114
124
130
90
90
114
124
142
80
80
80
130
130
F07
F10
F10
F12
F14
70
102
102
125
140
M8x13 M10x16 M10x16 M12x20 M16x25
Optional dimensions
32
54
50
50
35
70
55
55
F05
F10
F07
F07
F10
F10
50
102
70
70
102
102
M6x10 M10x16 M8x13 M8x13 M10x16 M10x16
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
516
637
337
380
30
95
45
28,5
265
301
70
95
95
82
1,5
46,16
46,00
60,2
60,5
130
154
280
130
F16
165
M20x30
F25*
-
Product data sheet
Sheet No.: BQ1.603.03 - Rev: 0
May 2014
Date:
Q-Series
Bettis Q-Series Valve Actuator Options
Drive Inserts
Description
All actuators are fitted with drive inserts. This enables
actuators to be directly mounted onto suitable valves and
eliminates the need for a bracket and coupling type mounting
kit. The use of direct mounts significantly cuts the cost of the
valve/actuator assembly.
Standard actuators are fitted with square drive inserts in
accordance with ISO 5211 (or DIN 3337), but a wide variety
of other inserts are also available. Special inserts may have
oversize or undersize squares, double-D and shaft key way
forms.
Standard available
insert shapes
Drive inserts can be supplied on factory built actuators or as
loose items and are easily replaceable at distributor or end
user level.
Where direct mounts are not possible, for instance on valves
with exposed gland packing, the use of inserts often simplifies
the design of the mounting kit.
Material :
Finish:
Optional available
insert shapes
D
Max.
sq
Max.
M1
Aluminum alloy
Anodized
Insert mounting
Insert mounting
acc. ISO 5211
acc. DIN 3337
Ø P2
Ø P2
Ø P1
Ø P1
M2
D
Max.
Q40
mm. inch
ISO5211
DIN3337
M1
M2
P1
P2
Sq max.
D max.
Q65
mm. inch
14
14
0.551
0.551
14
14
0.551
0.551
10
12
-
0.394
0.472
-
10
12
-
0.394
0.472
-
34.5
18.1
16
21
1.36
0.71
0.630
0.827
34.5
21.2
16
21
1.36
0.83
0.630
0.827
M1
M2
Center
plate
Inserts with inner-square-dimensions per actuator type
Q100
Q150
Q200
Q350
Q600
Q950
Q1600
mm. inch mm. inch mm. inch mm. inch mm. inch mm. inch mm. inch
Standard inserts dimensions
19 0.748 19 0.748 22 0.866 27 1.063 27 1.063 36 1.417 46 1.811
17 0.669 17 0.669 22 0.866 22 0.866 27 1.063 36 1.417 46 1.811
Optional insert dimensions
12 0.472 14 0.551 14 0.551 14 0.551 14 0.551 22 0.866
14 0.551 16 0.630 16 0.630 16 0.630 16 0.630
16 0.630 22 0.866 17 0.669 17 0.669 17 0.669
24 0.945 19 0.748 19 0.748 19 0.748
27 1.063 24 0.945 24 0.945 24 0.945
Maximum insert dimensions
34.5 1.36
50
1.97
50
1.97
50
1.97
50
1.97
65
2.56
81
3.19
27
1.06 37.0 1.46 37.0 1.46 37.0 1.46
23.5 0.93 28.5 1.12 32.2 1.27 32.2 1.27 36.8 1.45 48.3 1.90 60.5 2.38
25.2 0.99 36.2 1.43 36.3 1.43 36.3 1.43
19 0.748 27.0 1.063 27.0 1.063 27.0 1.063 27.0 1.063 36.0 1.417 46.0 1.811
23.6 0.929 33.6 1.323 33.6 1.323 33.6 1.323 33.6 1.323 45.0 1.772 60.0 2.362
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.606.05 - Rev: 0
May 2014
Date:
Q-Series
Bettis Q-Series Valve Actuator Options
Position Indication - Center Plate
Visual position indicator
“In line”
Bettis Q-Series valve actuators can be equipped with a large
visual position indicator which allows clear indication of the
valves position at almost any position.
The Bettis Q-Series indicator is designed for position
indication of actuators mounted “in line” with the pipe line and
mounted “cross line” with the pipe line. To do this the inner
part can be removed, turned 90° and pushed back in place.
When supplied, the position indicator will be mounted “in line”
as standard. See data sheet BQ1.606.04 for other indicator
mounting options.
Specifications:
Material disk
:
Material arrow :
“Cross line”
Nylon PA6, Black
Nylon PA6, White
Center plate for DIN3337 applications
Bettis Q-Series actuators can be equipped with a centre plate
which takes care that actuator and valve (or valve mounting
kit) are aligned when mounted. For most of the actuator sizes
two center plates are available.
Specifications:
Material plate
:
Nylon PA6, Black
Center plate
Bettis Q-Series actuator models
Q40
Q65
Std
F05
F05
Q100 Q200 Q350 Q600 Q950 Q1600
F07
F10
F10
F12
F14
F16
Option
F07
F07
F05
F07
F07
-/-
-/-
-/-
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.605.03 - Rev: 0
May 2014
Date:
Q-Series
Bettis Q-Series Valve Actuator Options
NAMUR Plate
Description
The top flange of the Bettis Q-Series actuator is standard
equipped with a NAMUR drilling pattern. The addition of a
NAMUR
adaptation plate makes the Bettis Q-Series actuator suitable
for mounting all kinds of NAMUR compatible control and
feedback accessories like solenoids, switch boxes or
positioners.
Backwards compatibility
Where the Bettis Q-Series is meant to be a integrated
concept for valve automation, there are a number of reasons
for also having NAMUR interfaces:
Emergency repairs
- When the Control Module requires immediate repair and
the process can only be stopped for a limited time, it would
be easy to mount standard available NAMUR accessories.
Future updates
- When a plant is not yet ready for digital (bus)
communication, but will be upgraded in the (near) future
towards this technology, it is easy to change from NAMUR
accessories to a Bettis Q-Series with bus communication.
Available equipment
- NAMUR compatible accessories are easy to acquire. Many
suppliers offer accessories that can be fitted to NAMUR
actuator interfaces.
Construction
The NAMUR adaptation plate is fitted in front of the actuator
Q40 - Q350 = 80 (3.15")
Q600 - Q1600 = 130 (5.12")
part of the Bettis Q-Series and replaces in fact the Pneumatic
Module.
Specifications:
Material
:Aluminum
Air connection : 1/4” BSP
Finish
: Housing :Anodized with a polyurethan
powder coating
:Pistons :Chromatized
Fasteners
: Stainless Steel
Seals
: Nitrile Rubber O-rings
Optional Temperature ranges
Special selected O-ring seals and grease makes it possible
to utilize the Bettis Q-Series actuator, with NAMUR plate, for
various temperature ranges. Three temperature ranges are
available:
-
-
-
Option code ST:80°C (176°F) / -20°C ( -4°F)
O-ring seals
:Nitrile rubber
Grease
:Castrol LMX
Option code HT:120°C(248°F) / -20°C ( -4°F)
O-ring seals
:Fluoro rubber (FPM) Viton®
Grease
:Castrol LMX
Option code LT:80°C (176°F) / -40°C (-40°F)
O-ring seals
:Silicone MVQ 70
Grease
:Castrol Optitemp TT1
Note:
Bettis Q-Series actuators fitted with Pneumatic Modules and
Control Modules are not available for high temperature or low
temperature applications.
Detailed Dimensions
See data sheets BQ1.603.05, BQ1.603.06 and BQ1.603.07.
30
(1.18")
90.5 (3.56")
2x 1/4"BSP (1/4"NPT)
32
(1.26")
M5x8
(10-24x0.31")
24 (0.94")
60 (2.36")
28 (1.10")
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.10 - Rev: 5, Page 1 of 11
Date:
April 2015
Q-Series
Integrated Control modules
QC41, QC42 and QC43
Features:
- Basic actuator functions for:
- Spring return applications, or
- Double acting applications or,
- Double acting Fail in Last Position applications.
APPROVED
- Suitable for all Bettis Q-Series actuator sizes.
- Available as "Weather Proof" for indoors or outdoors
use and "Explosion Proof" for areas with a potential
explosion hazard.
- The robust aluminum alloy enclosure (IP66 /
NEMA4X rated), protects the IPT system, pneumatic
components, the feedback switches and terminals and
makes it suitable for indoor and outdoor use.
- The Explosion Proof version is available with ATEX /
IECEx Ex d approval for use in Zone 1, 2, 21 and 22
and/or FM / CSA Explosion proof approval for use in
Class I, Division 1.
- Various feedback switch options available.
- Non-Intrusive switch point adjustment of the feedback
switches. Allows to adjust switch points without
opening the Control Module.
- Lockable Control Module cover.
- All the control and feedback connections can be wired
through one single entry to the Control Module.
- One larger entry (3/4"NPT) is available for larger multicore cables on imperial units.
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.10 - Rev: 5, Page 2 of 11
Date:
April 2015
Description:
Q-Series
Electrical safety requirements:
These Bettis Q-Series conventionally wired control modules
are the next step for the integrated concept of valve
automation.
Next to the components for feedback switches, also all
the pneumatic control components are located inside one
module housing.
Its compact and robust construction incorporates basic
control and feedback functionality and is suitable for indoor
and outdoor use.
These modules are available with ATEX and IECEx
certification for use in Zone 1, 2, 21 and 22, and additionally
FM and CSA certified for use in Class I, Division 1.
Use
Altitude
: In- and outdoor.
: Operating full power available up to 2000 meter (6000 feet).
Maximum relative
: 80% for temperatures up to 31°C
humidity (87.8°F) decreasing linearly to 50% relative humidity at 40°C (104°F).
Mains supply
: Up to ±10% of nominal voltage
fluctuation
Over voltage category : II
Pollution degree
: 2
(3 when the cover remains closed)
Construction:
The Control Module is mounted at the side of the basic
actuator housing. Inside, wiring terminals are available for
connecting control and feedback signals. Two cable entries
are available.
The pilot valves inside the control module are used to send
the actuator to its open or closed position. One pneumatic
connection is available to feed the control module.
General specifications:
Material housing:
Operating media:
Pneumatic entry:
Electrical connections:
Cable entries:
Enclosure:
Switch points:
- Adjustable range:
Finish:
Temperature range:
Dimensions:
Aluminium alloy
Air or inert gasses, filtered at 50µm
Metric units: G1/4"
Imperial units:1/4”NPT
Pilot valve(s): 6 pole terminal strip.
Switches:
6 pole terminal strip.
Metric units: 2x M20x1.5
Imperial units:1/2” and 3/4"NPT
Rated IP66 - NEMA4X
Factory set at 15° before each end
of travel (open and closed position).
Between -3° to 15° and +75° to
+93° of the end position.
Chromated, polyurethane based
coating.
Depends on the switches inside
the module and or Hazardous Area
approvals (See section "Position
feedback"
Metric:1.603.08
Imperial/UNC:1.603.09
DIN 3337:
1.603.10
Terminal
compartment
Control Module
Type Label
Option: 1 or 2
speed control
throttles
Lockable
Module cover
Pneumatic connections:
1/4”BSP or 1/4”NPT
Electrical entries:
3/4”NPT
or M20
Option: Additional Local
Manual Control for “Fail in
Last Position”
Option: Local Manual
Control
1/2”NPT
or M20
Switch
terminals
Pilot valve
terminals
Control module overview
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Non-Intrusive switch
point adjustment
Product data sheet
Sheet No.: BQ1.604.10 - Rev: 5, Page 3 of 11
Date:
April 2015
Q-Series
Pneumatic control
Pneumatic control variations
The Control Module contains all the necessary pneumatic
components to control the actuator and control the
incoming and outgoing airflow. Pneumatically the modules
are available for three applications:
1 Spring return or
2 Double acting or
3 Double Acting - "Fail-in-Last-Position".
To achieve these functions, each Control Module can be
fitted with one or two pilot valves depending on the required
functionality:
Pilot valve 1
Cable range:
0.2 - 2.5mm2 or
30-12AWG
One default pilot valve and wiring connections
1 One pilot valve is default and suitable for normal
operation of double acting or spring return actuators
2 Two pilot valves are required to achieve a "Fail-in-LastPosition" functionality on double acting actuators.
Pilot valve 1
Table 1: Pilot valve specifications
Module
Voltages
Power
QC41
24VDC (±10%)
1W
Frequency
NA
QC42
115 VAC (±10%)
3VA
50/60Hz
QC43
230 VAC (±10%)
3VA
50/60Hz
Pilot valve 2
Cable range:
0.2 - 2.5mm2 or
30-12AWG
FILP = Fail in Last Position
Wiring diagram shown, is applicable for actuators with assembly code “CW”.
For actuators with assembly code “CC” (reverse acting) the “Open” and
“Closed” pilot valve connections are also reversed.
Pneumatic cartridge
Pilot valve cartridge
Pilot valve
terminals
Two pilot valves and wiring connections for Fail in Last
Position
Pilot valve and pneumatic cartridge
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.10 - Rev: 5, Page 4 of 11
Date:
April 2015
Pneumatic components
The pneumatic components inside the module consist
out of one or two pilot valves and a 3/2 spool valve or 5/2
bistable spool valve. The spool valves are pneumatically
operated by the pilot valves.
To assure trouble-free operation, the spool valves are
equipped with big ports. This enables a large air flow and
makes it less sensitive for contamination of the internals.
The large air flow also fast cycle times and enables it to be
utilized for the entire Bettis Q-Series actuator range.
Internal corrosion protection:
The spring return models have standard a built in “Breather”
function. During the spring stroke, the exhaust air from the
center chamber (A-Port) is first fed to the spring chamber
(B-port) preventing air from outside from being sucked into
the spring chamber. This reduces the possibility of internal
corrosion and maximizes the actuators’ working life.
Pneumatic options
Q-Series
Fail safe
(spring return)
A-port
B-port
Option: Throttle 1
3/2 Spool valve
Option: LMC
Ps
Ra
Pilot valve 1
Double acting
Speed Control
The Bettis Q-Series can be supplied with a Speed Control
option. One throttle is required for Spring Return actuators
and up to two for Double Acting actuators.
The speed control throttle controls the air flow in and out
of an air chamber and as such limits the speed of the
“Opening” and “Closing” stroke simultaneously.
Silencers and vents
A-port
B-port
Option:
Throttle 1
Option:
Throttle 2
5/2 Spool valve
Option: LMC
Rb
Ps
Ra
The exhaust ports Ra and Rb on the module are shipped
from the factory with transport protection.
The module can be equipped with either silencers or vents.
Pilot valve 1
Manual Control
For commissioning, emergency or maintenance purposes,
the Bettis Q-Series can be supplied with Manual Control
options. These options can operate the actuator when there
is air pressure available, but no control signal or power
supply.
- For normal operation the module should be fitted with
one Manual Control.
- For Double Acting with a Fail-in-Last-Position function,
two Manual Control can be fitted.
Double Acting
Fail in Last
Position
A-port
Option:
Throttle 1
Option:
Throttle 2
5/2 Spool valve
Maximum Flow rates of Q-Series modules
The maximum flow rates depends mainly on the flow rates
of the Bettis Q-Series modules. You can use Kv 0.33 (m3/h)
or Cv value of 0.28 (US gall/min 1Psi) for approximate
operating speed calculations.
B-port
Option: LMC 1
Option: LMC 2
Ps
Rb
Ra
Pilot valve 1
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Pilot valve 2
Product data sheet
Sheet No.: BQ1.604.10 - Rev: 5, Page 5 of 11
Date:
April 2015
Q-Series
Position feedback
Non-Intrusive switch point adjustment
The position feedback is achieved by switch cartridges in
the module. These cartridges contain switching elements
which sense the open or closed position and are pre
wired to the terminal strip. These easily exchangeable
switch cartridges are available with various mechanical or
proximity switching elements.
If required the switches can be adjusted without opening the
module. This, so called, Non-Intrusive switch adjustment is
located at the front of the module behind a locable (1) shield
(2). Two adjustment screws are available for adjusting the
Closed (3) and Open (4) position indication.
N WHEN E
NING N
PE
O WAR
!-
G
ER
IZED
DO NO
T
Switch cartridges
Terminal strip position
feedback switches
3
4
1
2
Switch cartridge
Switch cartridges
"Closed"
Switch point adjustment
"Open"
Switch point adjustment
Non-Intrusive switch point adjustment
Important:
- The above "Closed" and "Open" marked adjustment
screws will adjust the valve's "Closed" or "Open" switch
point, if the valve closes after a Clock Wise (CW) rotation.
- If the valve closes after a Counter Clock Wise (CCW)
rotation, the "Closed" marked adjustment screw will adjust
the "Open" switch point. Similar, the "Open" marked
adjustment screw will adjust the "Closed" switch point.
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.10 - Rev: 5, Page 6 of 11
Date:
April 2015
Q-Series
Mechanical switches
2-Wire Proximity switches
Specification
Description
Specification
Description
Option code
M
Option code
N
Option code
G (gold contacts)
Type
2-wire inductive, normally closed
Type
Mechanical
Voltage
8 VDC nominal
Voltage
M: 277 VAC or 250VDC (maximum)
Output
Unswitched , > 3 mA
Temperature range
Switched , < 1 mA
-25°C to +65°C / -13°C to +149°F
For use in hazardous areas, see table 7
DIN EN 60947-5-6 (NAMUR)
Table 2: Mechanical switches
Table 4: 2-wire NAMUR proximity switches
G: 125 VAC or 30VDC (maximum)
Contacts
Temperature range
NO and NC
-25°C to +65°C / -13°C to +149°F
For use in hazardous areas, see table 7
Table 3: Maximum currents
Switch voltage
M type switch
G type switch
125 VAC
10 A (3 A1)
0.1 A 2
250 VAC
10 A (3 A1)
-
30 VDC
0.5 A
0.1 A 2
125 VDC
0.5 A
-
250 VDC
0.25 A
-
Note:
1. The mechanical (M-type) switches are rated for 3 A with
inductive load.
2 The mechanical (G-type) switches have gold contacts.
For applications where the benefits of gold contacts are
required, the maximum current is 1 A.
3. For applications below -20°C (-4°F), the base actuator
must be equipped with Low temperature seals.
Compliant to
Table 5: 2-Wire 230V proximity switches
Specification
Description
Option code
H
20...250VAC / 10...300VDC
(50...60 Hz AC)
Maximum
100 mA
Voltage
Current
Peak
Leakage
Temperature range
Note:
1 For applications below -20°C (-4°F), the base actuator
must be equipped with Low temperature seals.
Wiring diagram:
Wiring diagram:
- 2-Wire NAMUR proximity switches
- 2-Wire 115V proximity switches
- M = Mechanical
- G = Mechanical, gold contacts
1 L- 2
Open
0,9A (20ms / 0,5Hz),
< 1.7 mA
-25°C to +65°C / -13°C to +149°F
For use in hazardous areas, see table 7
Close
Cable range : 0.2 - 2.5mm2 or 30-12AWG
Wiring diagram is shown in the actuators mid-stroke position.
Wiring diagram for mechanical switches
L+ 3
4 L- 5
2
2
1
1
Open
L+ 6
Close
Cable range : 0.2 - 2.5mm or 30-12AWG
2
Wiring diagram for 2-Wire proximity switches
Important:
- The above "Closed" and "Open" marked adjustment terminals will indicate the valve's "Closed" or "Open" switch
point, if the valve closes after a Clock Wise (CW) rotation.
- If the valve closes after a Counter Clock Wise (CCW) rotation, the "Closed" marked adjustment terminals will indicate
the "Open" switch point. Similar, the "Open" marked adjustment terminals will indicate the "Closed" switch point.
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.10 - Rev: 5, Page 7 of 11
Date:
April 2015
Q-Series
3-Wire Proximity switches
Table 4: 3-wire proximity switches
Specification
Description
Option code
O, V3 PNP
Option code
C, V3 NPN
Function
Make
Voltage
10 - 30V
Current
100 mA maximum
Off-state current
0 ... 0.5 mA typical
-25°C to +65°C / -13°C to +149°F
For use in hazardous areas, see table 7
Temperature range
Note:
1 For applications below -20°C (-4°F), the base actuator
must be equipped with Low temperature seals.
Wiring diagram:
3-Wire proximity "O" type switches PNP
L-
2
1
L+
3
L-
5
4
3
4
1
L+
6
L+
6
3
4
1
PNP
Open
Close
Wiring diagram:
3-Wire proximity "C" type switches NPN
L-
2
1
L+
3
3
4
1
L-
5
4
3
4
1
NPN
Open
Close
Cable range : 0.2 - 2.5mm2 or 30-12AWG
Wiring diagram for 3-Wire proximity switches
Important:
- The above "Closed" and "Open" marked adjustment terminals will indicate the valve's "Closed" or "Open" switch
point, if the valve closes after a Clock Wise (CW) rotation.
- If the valve closes after a Counter Clock Wise (CCW) rotation, the "Closed" marked adjustment terminals will indicate
the "Open" switch point. Similar, the "Open" marked adjustment terminals will indicate the "Closed" switch point.
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.10 - Rev: 5, Page 8 of 11
Date:
April 2015
Q-Series
Control Module Options
QC41, QC42 and QC43
Local Manual Control
Speed Control
Description
Description
For commissioning, emergency or maintenance purposes,
the Bettis Q-Series can be supplied with one or two
Manual Control options. These can operate the pilot
valve(s) inside the module and as such operate the
actuator, when there is air pressure available, but no
control signal or power supply.
The Bettis Q-Series can be supplied with a Speed Control
option. One throttle is required for Spring Return actuators
and up to two for Double Acting actuators.
The speed control throttle controls the air flow in and
out of an air chamber and as such limits the speed of
the “Opening” and “Closing” stroke simultaneously. This
throttle consists of :
1 Nut cover
2 Main throttle with set screw.
Notes:
- One Local Manual Control is required for normal
operation of Double acting or Spring return actuators.
- For Double acting actuator with a Fail-in-last position
function, a second Local Manual Control can be
mounted.
- These options can be ordered together with the Control
Module or as a kit to be mounted later.
- For option ordering codes, see page 7
Note:
- For Spring Return actuators with one speed control
throttle, it is not possible to set both the stroke cycle
times to an equal time.
- Four Double Acting actuators it is possible to mount two
speed control throttles.
- The actual stroke cycle times depend on the actual load
on the actuator during the different strokes.
Spring Return:
Top entry only.
Double Acting:
Bottom and/or top entries.
Location for 2nd
Local Manual Control
Lock
45°
Default location of
Local Manual Control
Unlock
On
1
Off
Local Manual Control option
Speed control options
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
2
Product data sheet
Sheet No.: BQ1.604.10 - Rev: 5, Page 9 of 11
Date:
April 2015
Q-Series
Hazardous area specifications
Modules QC41, QC42 and QC43
Below specification are applicable for QC41, QC42 and QC43 modules with a hazardous area approval.
Hazardous area product marking;
FM hazardous or Classified Location:
IECEx hazardous or Classified Location:
APPROVED
Ex d IIB+H2 T4/T6 Gb
Ex t IIIC T80°C Db
IECEx DEK 15.0034X
CL I, II, III, DIV 1
Groups BCDEFG, T4/T6, Type 4X/6
CL l, ZN 1, IIB+H2, T4/T6
CSA hazardous or Classified Location:
ATEX hazardous or Classified Location:
Class I, II, III, DIV 1
Groups CDEFG, T4/T6, Type 4X/6
Ex d IIB+H2 T4/T6
DIP A21 TA 80°C
1180
II 2G Ex db IIB+H2 T4/T6
II 2D Ex tb IIIC T80°C
DEKRA 15ATEX0055X
Notes:
1 Each control module is marked with the applicable ambient temperature marking.
2 Metric control modules are marked with ATEX and IECEx markings.
3 Imperial control modules are marked with ATEX, IECEx, FM and CSA markings.
Temperature rating
Table 7: Temperature rating for use in areas with a potential explosion hazard.
Configuration
Module type
Switch cartridge
QC41 (24VDC)
QC42, QC43 (115 or 230VAC)
QC42, QC43 (115 or 230VAC)
Notes:
M, G
O, C, N, H
Temperature (°C)
Pneumatic
Max. Power
Min.
Max.
Max.
action
dissipation
ambient
ambient
Surface
S,D,F
3.6W (2
-25°C (-13°F)
+60
+80
T6/T4
S,D
3.6W (2
-25°C (-13°F)
+60
+80
T6/T4
F
7.2W (3
-25°C (-13°F)
+60
+80
T6/T4
1 1x or 2x 24VDC pilot valves, or 1x 115/230 VAC
pilot valve
2 2x 115 or 230 VAC pilot valves
Switch cartridge
M = Mechanical switches
G = Mechanical switches (gold contacts)
C = 3 wire PNP proximity switch
O = 3 wire NPN proximity switch
N = 2 wire proximity switch
H = 2 wire proximity switch
Pneumatic action
S = Spring Return (Single acting).
D = Double acting.
F = Double acting (Fail in Last Position)
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Class
Product data sheet
Sheet No.: BQ1.604.10 - Rev: 5, Page 10 of 11
Date:
April 2015
Q-Series
Corrosion protection Bettis Q-Series
Modules QC41, QC42 and QC43
Description
Technical data base actuator
The corrosion protection system of Bettis Q-Series
actuators consist of the following treatments or materials:
Finish:
Polyurethane powder coating
Thickness:
80 to 160 micrometer (3.1 to 6.2 mils).
Salt spray test: 1000 hours (ASTM B117)
Color:Yellow
Materials:
Housing:
Anodized aluminium alloy
Pistons:Chromatized
Pinion: High grade aluminum alloy,
hard anodized
Fasteners: Stainless steel or coated
alloy steel.
Type plate: Stainless steel
1 Pretreatment
The actuator housings are anodized inside and outside, to
give them a durable and superb protection against wear
and corrosion.
2 De-greasing.
All aluminum parts are de-greased before the coating is
applied by washing with an alkaline solution to assure
the best bonding between the aluminum surface and the
coating.
3 Finish
3.1 Actuator
Polyurethane powder coating for exterior use.
The powder coating is applied cold using automatic
electrostatic spray equipment and is cured for about 10
minutes at minimum 200°C (392°F) offering excellent light
and weather resistance.
3.2 Module
Polyurethane coating for exterior use.
The coating offers excellent light and weather resistance.
Good chemical resistance against most bases, acids,
solvents, alkalis and oils at normal temperatures.
Excellent exterior mechanical durability.
Technical data Control Module
Finish:
2 Component with an epoxy primer and
polyurethane enamel top coating.
Thickness: 80 to 160 micrometer (3.1 to 6.2 mils).
Salt spray test: 1000 hours (ASTM B117)
Color: Yellow
Materials: Housing: Anodized aluminium alloy
Fasteners: Stainless steel or coated
alloy steel.
Type plate: Vinyl
Base
actuator
4 High grade & hard anodized aluminum pinion.
Module
Actuators with high grade & hard anodized aluminum
pinions, passed a 1000 hours salt spray test.
5 Stainless steel or coated steel parts.
External parts are stainless steel or coated alloy steel.
6 Corrosion protected springs on Spring Return
actuators
All the springs of spring return actuator are Deltatone®
or epoxy (black) coated to prevent the corrosion of the
springs and assure a long cycle life.
Stainless steel
Fasteners
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.10 - Rev: 5, Page 11 of 11
Date:
April 2015
Q-Series
Control Module Configuration:
Modules QC41, QC42 and QC43
Sample code:
QC41 • UWPM S K 1 • 0040 INS 0 IP
Pneumatic exhaust
Manual Control
Speed control
Mounting Options
IPT Device size actuator
Language Code
Future Expansions Code
Action
Control module options
Protection method
Conduit connections
Control module
Control module
QC41
Control module with 24 VDC pilot valve
QC42
Control module with 115 VAC pilot valve
QC43
Control module with 230 VAC pilot valve
Connections
M
Metric
U
NPT
Protection method
WP
Weather Proof IP66/NEMA4X
P5
Flame- or Explosion proof approval (see note 1)
Control module options (position feedback)
M
Mechanical switch
G
Mechanical switch (Gold Plated)
O
3-wire prox. switch PNP
C
3-wire prox. switch NPN
N
2-wire prox. switch (NAMUR)
H
2-wire prox. switch (20-140 VAC/10-140 VDC)
Action
S
D
F
Single acting actuator
Double acting actuator
Double Acting - Fail-In-Last-Position
Future Expansions Code
K
Standard
Language Code
1
English
QC41 • UWPMSA1 • 0150INS0IP
- Control module with 24 VDC pilot valve
•
- Imperial unit with 1/2"NPT and 3/4"NPT
electrical entries and 1/4"NPT pneumatic
entry.
- Weather proof module (IP66/NEMA4x)
- Mechanical feedback switches
- Suitable for Spring Return actuators
•
- With IPT probe for Q150 size actuator
- Not installed to actuator (separate
Control module)
- No speed control option
- No manual control option
- With IP65/NEMA4 exhaust
IPT Device size for actuator:
0040
Q40 actuator
0065
Q65 actuator
0100
Q100 actuator
0150
Q150 actuator
0200
Q200 actuator
0350
Q350 actuator
0600
Q600 actuator
0950
Q950 actuator
1600
Q1600 actuator
0000
No IPT probe
Mounting Options
U
Uninstalled
I
Installed/Tested to actuator
Speed control
NS
No Speed Control
N1
Spring Return (1x throttle)
N2
Double acting (2x throttle)
Manual Control
0
No Manual Control
1
1x "Push&Lock", anodized aluminum
2
2x "Push&Lock", anodized aluminum
Pneumatic exhaust
IP
IP65/NEMA4 rated exhaust
IN
Non metalic exhaust / Check valve
ZZ
Special exhaust
Note: 1 Metric control modules are marked with ATEX and IECEx markings.
2 Imperial control modules are marked with ATEX, IECEx, FM and CSA markings.
3 The options below are all options available. Not all options apply to all configurations.
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.12 - Rev: 0, Page 1 of 11
October 2015
Date:
Q-Series
Integrated Control modules
QC54 with FOUNDATION™ Fieldbus digital communication.
Features:
- Basic actuator functions for:
- Spring return applications, or
- Double acting applications or,
- Double acting Fail in Last Position applications.
- Suitable for all Q-Series actuator sizes.
- FOUNDATION™-Fieldbus digital communication.
- IPT-technology (Intelligent Position Tracking).
- Initialization by FOUNDATION™- Fieldbus or Push
Button for easy setup of the actuator.
- Press and confirm press the "Auto-Init" button starts
auto-initialization procedure.
- Initialization sets automatically the switch points for the
position feedback of the actuator.
- Initialization checks if the actuator and control
module configuration match. This procedure will
detect the action type (Fail-Open, Fail-Close or Fail
in last position) and generate an alert if there is a
configuration issue.
- Readjustable or Reversible position feedback using
the re-reassignment buttons or by FOUNDATION™
Fieldbus.
- Adjustable switch points can be adjusted from 5% to
30% before the end of the stroke by FOUNDATION™
Fieldbus.
- Three indication LED's for "Status", "Open" and
"Closed" position. Status LED indicates:
- Initialization procedure running (blinking),
- Successful initialization procedure (LED is on) or
- No or failed initialization (flashing) or
- A particular unit in the field.
Fig. 1. Control module QC54 with
FOUNDATION™-Fieldbus bus communication
- Available as "Weather Proof" for indoors or
outdoors use.
- The robust aluminum alloy enclosure (IP66/
NEMA4X rated), protects the IPT system, pneumatic
components, the feedback switches and terminals and
makes it suitable for indoor and outdoor use.
- Lockable Control Module cover.
- One larger entry (3/4"NPT) is available for larger multicore cables on imperial units.
- Control Module can be easily mounted to the actuator
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.12 - Rev: 0, Page 2 of 11
October 2015
Date:
Q-Series
Description:
This Q-Series QC54 Control Module offers an
integrated concept for valve automation. Its compact
and robust construction incorporates basic control and
feedback functionality and communicates through the
FOUNDATION™- Fieldbus protocol.
All electrical and pneumatic control components are
located inside one module housing making it a compact
and robust construction incorporating basic control and
feedback functionality and is suitable for indoor and
outdoor use.
Construction:
The Control Module is mounted at the side of the basic
actuator housing. Inside, wiring terminals are available
for connecting the FOUNDATION™- Fieldbus signals. Two
cable entries are available.
One pneumatic connection is available to feed the control
module. The pilot valves inside the control module are
used to send the actuator to its open or closed position.
Terminal
compartment
Control Module
Type Label
Option: 1 or 2
speed control
throttles
Lockable
Module cover
Pneumatic connections:
1/4”BSP or 1/4”NPT
Button board
Electrical entries:
3/4”NPT
or M20
1/2”NPT
or M20
Terminals
bus signal
Option: Local
Manual Control
Option: Additional Local
Manual Control for “Fail in
Last Position”
Fig. 2. Control module overview
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.12 - Rev: 0, Page 3 of 11
October 2015
Date:
Q-Series
General specifications:
Communication Protocol:
Material housing:
Aluminium alloy
Operating media:
Air or inert gasses, filtered at 5µm
Pneumatic entry:
Metric units: G1/4"
Imperial units:1/4”NPT
Electrical connections : Internal 3 pole terminal strip for
bus signal
Internal and external earth
connection
Optional quick connectors: 7/8" or
M12 connector (see page 9)
Cable entries:
Metric units: 2x M20x1.5
Imperial units:1/2” and 3/4"NPT
Enclosure:
Rated IP66 - NEMA4X
Switch points:
Factory set at 15° before each
end of travel (open and closed
position).
- Adjustable range:
Between -3° to 15° and +75° to
+93° of the end position.
Finish:
Chromated with polyurethane
based coating.
Temperature range: -20°C to +50°C (-4°F to +122°F)
Protocol :
Transmission : Maximum current : Required external : protection current Dimensions:
Metric:
Imperial/UNC:
DIN 3337:
See data sheet 1.603.08
See data sheet 1.603.09
See data sheet 1.603.10
Electrical safety requirements:
Use:
Altitude:
Maximum relative:
humidity
In- and outdoor.
Operating full power available up
to 2000 meter (6000 feet).
80% for temperatures up to 31°C
(87.8°F) decreasing linearly to
50% relative humidity at 40°C
(104°F).
Up to ±10% of nominal voltage
FOUNDATION™-Fieldbus
H1, IEC 61158-2
18mA from bus
Restrict the power supply
to <600mA.
Function blocks
The Control Module provides the following function blocks:
- Resource Block (RB)
- Transducer Block (TB)
- Analog Input (AI) Function Block
- Discrete Output (DO) Function Block
- 2x Discrete Input (DI) Function Block
- PID Function Block
Diagnostics and Alerts
Standard FOUNDATION™- Fieldbus diagnostics and
alerts provided meets Emerson PlantWeb Alerts standard.
Applicable diagnostics include:
- Travel times for the Open stroke, Close stroke and
Average travel times.
- Cycle Counters for Control Module, Pneumatic
Module, Actuator and Valve
- Time in Position
- Various internal electronic health tests.
- Instrument temperature.
For more detailed information on diagnostics see page 10
and 11.
Mains supply:
fluctuation
Over voltage category: II
Pollution degree:
2 (3 when the cover remains
closed)
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.12 - Rev: 0, Page 4 of 11
October 2015
Date:
Q-Series
Pneumatic control
Pneumatic control variations
The Control Module contains all the necessary pneumatic
components to control the actuator and control the
incoming and outgoing airflow. Pneumatically the modules
are available for three applications:
1 Spring return or
2 Double acting or
3 Double Acting - "Fail-in-Last-Position".
To achieve these functions, each Control Module can
be fitted with one or two pilot valves depending on the
required functionality:
1 One pilot valve is default and suitable for normal
operation of double acting or spring return actuators
2 Two pilot valves are required to achieve a "Fail-inLast-Position" functionality on double acting actuators.
Terminals
FOUNDATION
Field bus
Cartridge
Pilot valve 1
Cable range:
0.2 - 2.5mm2 or 30-12AWG
Fig. 4. One pilot valve and wiring connections for standard
Double Acting or Spring Return applications
Terminals
FOUNDATION
Field bus
Cartridge
Pilot valve 1
Pilot valve 2
Cable range:
0.2 - 2.5mm2 or 30-12AWG
Pneumatic cartridge
FOUNDATION™
Fieldbus cartridge
Terminals
bus signal
Fig. 5. Two pilot valves and wiring connections for Double
Acting "Fail in Last Position" applications
Fig. 3. Pilot valve and pneumatic cartridge
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.12 - Rev: 0, Page 5 of 11
October 2015
Date:
Pneumatic components
The pneumatic components inside the module consist
out of one or two pilot valves and a 3/2 spool valve or 5/2
bistable spool valve. The spool valves are pneumatically
operated by the pilot valves.
To assure trouble-free operation, the spool valves are
equipped with big ports. This enables a large air flow and
makes it less sensitive for contamination of the internals.
The large air flow also fast cycle times and enables it to be
utilized for the entire Q-Series Series actuator range.
Internal corrosion protection:
The spring return models have standard a built in
“Breather” function. During the spring stroke, the exhaust
air from the center chamber (A-Port) is first fed to the
spring chamber (B-port) preventing air from outside from
being sucked into the spring chamber. This reduces
the possibility of internal corrosion and maximizes the
actuators’ working life.
Q-Series
Fail safe
(spring return)
A-port
B-port
Option: Throttle 1
3/2 Spool valve
Option: LMC
Ps
Ra
Pilot valve 1
Double acting
Pneumatic options
Speed Control
The QC54 control module can be supplied with a Speed
Control option. One throttle is required for Spring Return
actuators and up to two for Double Acting actuators.
The speed control throttle controls the air flow in and out
of an air chamber and as such limits the speed of the
“Opening” and “Closing” stroke simultaneously.
A-port
5/2 Spool valve
Rb
Ps
Ra
Pilot valve 1
The exhaust ports Ra and Rb on the module are shipped
from the factory with transport protection.
The module can be equipped with either silencers or
vents.
For commissioning, emergency or maintenance purposes,
the QC54 control module can be supplied with Manual
Control options. These options can operate the actuator
when there is air pressure available, but no control signal
or power supply.
- For normal operation the module should be fitted with
one Manual Control.
- For Double Acting with a Fail-in-Last-Position function,
two Manual Control can be fitted.
Option:
Throttle 2
Option: LMC
Silencers and vents
Manual Control
B-port
Option:
Throttle 1
Double Acting
Fail in Last
Position
A-port
Option:
Throttle 1
B-port
Option:
Throttle 2
5/2 Spool valve
Option: LMC 1
Option: LMC 2
Ps
Rb
Ra
Pilot valve 1
Fig. 6. Pneumatic operation
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Pilot valve 2
Product data sheet
Sheet No.: BQ1.604.12 - Rev: 0, Page 6 of 11
October 2015
Date:
Q-Series
Switch point setting
The QC54 control modules are equipped with a button
board that allows you to set or readjust the switch points
for the position feed back.
Closed reassignment button
Status LED
Press and
confirm press
Open reassignment button
on
LED = Flashing
off
Auto-Initialization
Initialization sets automatically the switch points for
the position feedback of the actuator and checks if the
actuator and control module configuration match. This
procedure will detect the action type (Fail-Open, FailClose or Fail in last position) and generate an alert if
there are configuration issues.
This process is done automatically, by the module,
however, the user must start it and the unit must be wired
and powered.
Digital communication is not required but power supply is
necessary (9V to 32V DC). The initialization process can
be started in one of two ways:
1. Initialization using the local buttons (see fig. 7).
2. Initialization using a bus command (see Reference
manual QC54, DOC.RM.QC54.E)
Indication LED's
on
LED = Blinking
off
Time
* The default setting of The reassignment buttons is: enabled when
the unit is in “Out of Service”.
* ”Open” and “Closed” LED are disabled.
Fig. 7. Button board
Button board functions:
Initialization button:
Start Auto-Initialization procedure
Re-adjustment of the "Closed" switch point
Close button:
Set to factory settings
Re-adjustment of the "Closed" switch point
Open button:
Set to factory settings
End stop
offsets
End stop offsets
Recognize Function
An additional function of the Status LED is the recognize
function. To recognzie a particular unit in the plant, the
"Recognizing LED" function can be activated in the
transducer block. When this function is activated, the
Status LED will blink for 300 seconds (5 minutes).
Changing Switch Point Setting
Readjustment of switch points
10°max
“Close”
end
position
±40°
±40°
Three indication LED's for "Status", "Open" and "Closed"
position are available. The status LED indicates:
- Initialization procedure running (blinking),
- Successful initialization procedure (LED is on) or
- No or failed initialization (flashing)
10°max
When switch point re-adjustment is required but it is
not allowed that the actuator/valve unit cycles, the new
switch point can be set by pressing the corresponding
"Open" or "Closed" button.
Factory settings
Pressing both the Open and Close reassignment buttons,
while powering up, will set the module back to its factory
settings.
“Open”
end position
Factory settings
Setting after initialization
Fig. 8. Switch point setting
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.12 - Rev: 0, Page 7 of 11
October 2015
Date:
Q-Series
Control Module Options
Local Manual Control
Speed Control
Description
Description
For commissioning, emergency or maintenance purposes,
the QC54 control module can be supplied with one or
two Manual Control options. These can operate the
pilot valve(s) inside the module and as such operate the
actuator, when there is air pressure available, but no
control signal or power supply.
The QC54 control module can be supplied with a Speed
Control option. One throttle is required for Spring Return
actuators and up to two for Double Acting actuators.
The speed control throttle controls the air flow in and
out of an air chamber and as such limits the speed of
the “Opening” and “Closing” stroke simultaneously. This
throttle consists of :
1 Nut cover
2 Main throttle with set screw.
Notes:
-
-
-
-
One Local Manual Control is required for normal
operation of Double acting or Spring return actuators.
For Double acting actuator with a Fail-in-last position
function, a second Local Manual Control can be
mounted.
These options can be ordered together with the
Control Module or as a kit to be mounted later.
For option ordering codes, see page 7
Note:
-
-
-
For Spring Return actuators with one speed control
throttle, it is not possible to set both the stroke cycle
times to an equal time.
Four Double Acting actuators it is possible to mount
two speed control throttles.
The actual stroke cycle times depend on the actual
load on the actuator during the different strokes.
Spring Return:
Top entry only.
Double Acting:
Bottom and/or top entries.
Location for 2nd
Local Manual Control
Lock
Default location of
Local Manual Control
45°
Unlock
On
1
Off
Fig. 9. Local Manual Control option
Fig. 10. Speed control options
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
2
Product data sheet
Sheet No.: BQ1.604.12 - Rev: 0, Page 8 of 11
October 2015
Date:
Q-Series
Wiring and Quick Connectors
FOUNDATION™ Fieldbus terminal wiring
Wiring for hazardous areas
The QC54 module can be connected to the system
by hard wiring the module to the terminals The QC54
Module can optionally be equipped with prewired quick
connectors. Two versions are available: 7/8” or M12 (male
chassis part).
Detailed safe area, Intrinsically safe or Non-Incendive/
Non-Sparking wiring instructions, will be shipped with the
product, see Installation Guide : DOC.IG.BQC54.1
Field wiring
Quick connectors, as shown are excluded for nonIncendive or non-sparking use in hazardous area’s
classified as Zone 2 or 22 or Cl I, II, III, Div. 2.
Actuator wiring
+ 1
FF
Power
supply
Quick connectors
Wiring dimensions
2
- 3
Solid wire Stranded wire
:2.5mm2 max.
:0.2-3.3mm2 or 24-12 AWG
Quick connector pinouts:
(male chassis part)
1
3
2
4
7/8" UNC
4
1
3
2
2
4
1
Blue
1
Brown
2
Green/Yellow
M12
Quick
connector
3
Terminal
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.12 - Rev: 0, Page 9 of 11
October 2015
Date:
Q-Series
Diagnostics and PlantWeb Alerts
QC54 FOUNDATION™ Fieldbus
Diagnostics
PlantWeb Alerts
The Q-Series QC54 Control Module with FOUNDATION™
Fieldbus communication has diagnostic capabilities.
These process parameters can give information about
communication condition, valve and/or actuator unit.
It enables to predict failures in advance and makes
maintenance easier to schedule. The following diagnostics
are available for the QC54 control module:
PlantWeb Alerts are alerts that have been predefined and
categorized for the user. These device alerts can be used
to help troubleshoot the instrument (see also page 4).
There are three categories:
-
Failed alerts,
A failed alert indicates a failure within the device that
will make the device, or some part of the device, nonoperational.
1 Timer parameters:
1
Open and Closed travel time
2
High and low limits of Open and Closed
travel time
3
Average travel times of last 30 strokes of
Open and Closed travel.
4
High and low limits of average Open and
Closed travel time
-
Maintenance alerts
A maintenance alert indicates that the device, or some
part of the device, needs maintenance soon.
-
Advisory alerts
An advisory alert indicates a condition that does not
have a direct impact on the device’s primary function.
If the condition is ignored, the device will eventually
fail.
2 Cycle Counters
1.
Control Module - Counts how many times
the Control Module cycles (read only).
2.
Pneumatic Module - Counts how many times
the Pneumatic Module cycles.
3.
Actuator - Counts how many times the
actuator cycles.
4.
Valve - Counts how many times the valve
cycles.
These alerts, when enabled, can participate in the DeltaV
alarm interface tools such as the alarm banner, alarm list,
and alarm summary.
3 Time In Position
5 Various internal electronic health tests.
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.12 - Rev: 0, Page 10 of 11
October 2015
Date:
Q-Series
Diagnostics and PlantWeb Alerts
Alerts & recommended actions
Alert default setting
Advisory
Alerts
Recommended actions
bit 0
Reserved
bit 1
Internal alerts, bad position sensor
bit 4
Internal alerts, bad temperature
sensor
Internal alerts, Specified system
temperature exceeded
Internal alerts, Software error
bit 5
Internal alert, travel deviation
bit 6
Internal alerts, Shutdown is set
bit 7
Internal alerts, Undefined error
Counter alerts, Control Module life
cycle exceeded
Counter alerts, Pneumatic Module
life cycle exceeded
Counter alerts, Actuator life cycle
exceeded
Counter alerts, Valve life cycle
exceeded
bit 2
bit 3
bit 8
bit 9
bit 10
bit 11
bit 12
Timer alerts: time in position limit
bit 16
Timer alerts: open travel time limit
exceeded
Timer alerts: close travel time limit
exceeded
Initialization Failed (reason from
AUTO_INITIALIZATION STATUS)
Reserved Primary Value Failure
bit 18
Reserved HW/SW Incompatibility
bit 13
bit 14
bit 15
Feedback problem, replace control
module when possible
Temperature sensor problem, replace
Control Module when possible
Take corrective actions to bring temperature within specified range.
Lost position, Check air pressure
Internal communications problem,
check shutdown configuration for
restart, Replace Control Module.
Control Module life cycle exceeded,
Replace Control Module
Pneumatic Module life cycle exceeded, Replace Pneumatic Module.
Actuator life cycle exceeded, Replace actuator.
Valve life cycle exceeded, take Valve
requires maintenance.
Time in position exceeded, appropriate action.
Open travel timer exceeded, check
valve system.
Close travel timer exceeded, check
valve system.
Check air pressure, check actuator
sizing, check valve system.
Internal communications are lost,
Reserved IO Failure (FF card lost IO
bit 19
device will act according to shutdown
board)
configuration.
bit 20
Reserved Mechanical Failure
Maintenance
Fail
enable
mask *
enable
mask *
enable
mask *
n
n
y
y
n
n
n
y
y
n
n
n
y
y
n
n
n
y
n
n
n
y
y
n
n
n
n
n
n
n
n
y
n
n
y
n
n
n
n
y
y
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
y
y
n
n
n
n
n
n
n
n
y
y
n
n
n
n
n
n
y
n
n
n
n
n
n
n
n
n
n
n
bit 21
Reserved TB NV Memory Failure
bit 22
Reserved RB NV Memory Failure
y
y
n
n
n
n
bit 23
Reserved TB Electronics Failure
y
n
n
n
n
n
bit 24
Reserved RB Electronics Failure
y
y
n
n
n
n
*) Mask “n” indicates masked out (not visible).
For more detailed information about the configuration of the QC54 Foundation Fieldbus Module see Reference Manual
DOC.RM.BQC54.E. This manual is available for download from www.Bettis.com.
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.604.12 - Rev: 0, Page 11 of 11
October 2015
Date:
Q-Series
Control Module Configuration:
QC54.UWPG SK1.0040 INS0 IP 01
Sample code:
QC54 • UWPSSK1 • 0150INS0IP01
Top entry glands and plugs
-Control module with
Bottom entry glands and plugs
FOUNDATION™ Fieldbus
Pneumatic exhaust
•
Manual Control
-Imperial unit with 1/2"NPT and
Speed control
3/4"NPT electrical entries and
Mounting Options
1/4"NPT pneumatic entry.
-Weather Proof
IPT Device size actuator
-Standard control module
Language
-Suitable for Spring Return actuators
Future Expansions
•
Action
-With IPT probe for Q0150 size
Control module options
actuator
-Installed to actuator.
Protection method
-No speed control option
Conduit connections
-No manual control option
Control module
-With IP65/NEMA4 exhaust
-Transport plug in bottom entry
-Metal blind plug in top entry
Control Module Type
QC54 Foundation Fieldbus communication
●
Conduit connections
M
2x M20 x 1.5
U
Top: 3/4"NPT, Bottom: 1/2" NPT
Protection method
WP
Weatherproof: IP66/NEMA4X (no approvals)
Control Module Switch Type
S
Standard configuration (only for QC54)
Module Action
S
Single acting
D
Double acting
F
Double Acting Fail in Last Position
Future Expansion
K
Standard Orange
Language Code
1
English
●
IPT probe size for actuator
0040 Q40 actuator
0065 Q65 actuator
0100 Q100 actuator
0150 Q150 actuator
0200 Q200 actuator
0350 Q350 actuator
0600 Q600 actuator
0950 Q950 actuator
1600 Q1600 actuator
0000 No IPT probe
Mounting Options
I
Installed On Actuator
U
Uninstalled
Speed control
NS
No Speed Control
N1
Spring Return (1x throttle)
N2
Double acting (2x throttle)
Manual Control
0
No Manual Control
1
1 x Manual Control (Push&Lock)
2
2 x Manual Control (Push&Lock)
Pneumatic exhaust
IP
IP65/NEMA4 rated exhaust
IN
Non metalic exhaust / Check valve
ZZ
Special exhaust
Glands & Plugs (see note 1)
Bottom entry
0
Transport plug
1
Metal blind plug
2
Plastic Gland
3
Metal Gland
4
Eurofast (M12)
5
Minifast (7/8”)
Top entry
0
Transport plug
1
Metal blind plug
2
Plastic Gland
3
Metal Gland
4
Eurofast (M12)
5
Minifast (7/8”)
Note:
1 The options below are all options available. Not all options apply to
all configurations.
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.606.01 - Rev: 0, Page 1 of 2
May 2014
Date:
Q-Series
Bettis Q-Series valve actuator
Parts and materials Actuator and Modules
Qty.
Description
Specification
Body
Description
1
Aluminum Alloy
EN AC-AlSi10Mg (Cu)
Notes
Pinion
1
Aluminum Alloy
EN AW 7075 T6
2
Upper pinion part
1
Aluminum Alloy
EN AW 7075 T6
2
Guide band housing
2*
Nylatron
PA6.6 + MoS2
-
Washer pinion
2*
CRMZX100
-
-
Bearing ring
2*
Delrin®POM
-
Limit stop cam
1
Steel
42CrMo4V
-
Piston
2
Aluminum Alloy
EN AC-AlSi7Mg
6
End cap QS
2
Aluminum Alloy
EN AC-AlSi7Mg
1
End cap QD
2
Aluminum Alloy
EN AC-AlSi7Mg
1
Guide band piston
2*
PTFE, Carbon filled
PTFE + 25% C
-
O-ring piston
2*
Nitrile Rubber
NBR
-
O-ring end cap
2*
Nitrile Rubber
NBR
-
O-ring upper pinion part
1*
Nitrile Rubber
NBR
-
O-ring pinion top
1*
Nitrile Rubber
NBR
-
O-ring pinion bottom
1*
Nitrile Rubber
NBR
-
O-ring B-port
2*
Nitrile Rubber
NBR
-
O-ring retainer bolt
4*
Nitrile Rubber
NBR
-
O-ring limit stop bolt
2*
Nitrile Rubber
NBR
-
Outer spring
2
Carbon Spring Steel
EN 10270-1 SH
3
Middle spring
2
Carbon Spring Steel
EN 10270-1 SH
3
Inner spring
2
Carbon Spring Steel
EN 10270-1 SH
3
Spring retainer
2
Steel
St. DC01 EN10139
4
Washer springpack
2
Steel
C35
4
Springpack retainer bolt
2
Stainless Steel
AISI 304 (DIN W nr 1.4301)
-
Washer
4*Nylon
PA6
-
Nut
4
Stainless Steel
AISI 304 (DIN W nr 1.4301)
-
Nut cover
2
Polyethylene
PE
-
End cap screws
8
Stainless Steel
AISI 304 (DIN W nr 1.4301)
-
Retaining ring pinion large
1*
Carbon Spring Steel
C45, DIN 17200
3
Retaining ring pinion small
1*
Carbon Spring Steel
C45, DIN 17200
3
Limit stop screw
1
Stainless Steel
AISI 304 (DIN W nr 1.4301)
-
Indicator cap
1
Nylon
PA6
-
Indicator arrow
1
Nylon
PA6
-
Indicator insert
1
Nylon
PA6
-
Type plate
1
Stainless Steel
AISI 303 (DIN W nr 1.4305)
-
Hammer drive
1
Stainless Steel
AISI 303 (DIN W nr 1.4305)
-
Insert
1
Aluminum Alloy
EN AW 6082 T5
5
1/5
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Notes
1 See Corrosion protection
below
2 Hard anodized.
3Deltatone® or Epoxy
(black) coating.
4 Zinc plated and
passivated.
5Anodized.
6Chromatized
Control & Pneumatic
Modules
For material specification of
the Pneumatic Modules see
page 2
Corrosion protection
The applied paint system
has passed a 1000 hour salt
spray test as detailed by
ASTM B117. For a detailed
description of the Corrosion
protection system see data
sheet BQ1.606.05.
Temperature ranges
The temperature range of
Bettis Q-Series actuators
with NAMUR plates depends
on the O-ring seals and the
utilized grease.
For a detailed description of
posible temperature ranges
and applied parts, see data
sheet BQ1.605.03
Repair kit
Parts marked with an * are
included in the repair kit
Product data sheet
Sheet No.: BQ1.606.01 - Rev: 0, Page 2 of 2
Date:
May 2014
Q-Series
Bettis Q-Series actuator
Parts and materials - Modules
Base Materials
Bodies:Aluminium
Finish:
2 Component with an epoxy
primer and polyurethane enamel
top coating.
Pneumatic cartridge: Aluminium
Valve seats
NBR
Fasteners
Stainless Steel
3
External parts
1 Plug
NPT:
2 Exhaust Base :
Cover:
Steel, Nickel plated
Nylon PA6
Zinc Nickel plated and transparent
passivated
Option: Plastic silencer (nylon)
3 Speed Control:
Stainless Steel (AISI 303)
4 Manual Control:
Red anodized aluminum
5 Nut Covers:
Nylon PA6
1
2
4
Modules QC41, QC42 and QC43
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Product data sheet
Sheet No.: BQ1.606.02 - Rev: 0
May 2014
Date:
Q-Series
Bettis Q-Series valve actuator
Failure modes
Valve rotation
Closed
Valves are normally manufactured so that:
1 The valve is closed
2 The valve is open
*) = views from above
:after a clock wise rotation*
:after a counter clock wise
rotation*
Open
Position after a failure
The position of the actuator after a failure depends on:
1 Principles of operation Spring Return or Double Acting
2 Actuator assembly code
See BQ1.606.03 for Double Acting
See BQ1.606.04 for Spring Return
3 Kind of failure See table.
Principle
of
operation:
Assembly
code :
CW
Double acting
actuator
CC
Single acting
actuator
(Spring Return)
CW
CC
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
Kind
of
failure :
Pressure
not defined
Signal
Closed
Supply voltage
Closed
Pressure
not defined
Signal
Open
Supply voltage
Open
Pressure
Closed
Position :
Signal
Closed
Supply voltage
Closed
Pressure
Open
Signal
Open
Supply voltage
Open
Product data sheet
Sheet No.: BQ1.606.03 - Rev: 0
May 2014
Date:
Q-Series
B
B
A
A
Actuator assembly codes
Double acting assembly codes
2
Standard assembly code:
1
CW
(= Clock Wise Rotation)
Visual indicator mounted:
Optional assembly code:
2
1
A
2
2
A
A
B
2
2
1
I
B
Position
indicator
B
CC
Visual indicator mounted:
(= for In line position indication
Pinion
B
2
(= Counter Clock Wise Rotation)
I
(= for In line position indication
A
2
1
2
2
B
1
1
2
2
B
A
A
Pistons
2
1
Optional assembly code:
A
2
2
2
1
2
1
A
A
B
B
2
2
2
1
- Central air chamber (1) pressurized
- End cap air chambers (2) pressurized
All views are from above. Pistons are shown in inner position
2
2
1
C
A
1
2
A= Pilot valve operated in Control Module B= Pilot valve
not operated in Control Module B
CC
(= Counter Clock Wise Rotation)
Visual indicator mounted:
B (= for Cross line position indication
C
2
A
2
Optional assembly code:
CW
(= Clock Wise Rotation)
A
Visual indicator mounted:
(= for CrossBline position indication
B
2
2
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)
2
Product data sheet
Sheet No.: BQ1.606.04 - Rev: 0
May 2014
Date:
Q-Series
B
B
A
A
Actuator assembly codes
Single acting (Spring Return) assembly codes
2
Standard assembly code:
2
CW
1
(= Clock Wise Rotation / Spring to Close)
Visual indicator mounted:
Optional assembly code:
I
(= for In line position indication
Visual indicator mounted:
(= for In line position indication
Pinion
B
B
2
I
A
A
B
2
2
2
B
2
1
1
2
A
B
CW
C
2
A
B
(= Counter Clock Wise Rotation/ Spring
to Open)
Visual indicator mounted:
(= for Cross line position indication
2
2
1
1
2
A
Pilot valve operated in Control Module PilotBvalve not operated in Control Module CC
A
B
B
1
2
2
2
1
- Central air chamber (1) pressurized
- Spring stroke (2)
2
1
CC
A
All views are from above. Pistons are shown in inner position
2
2
Optional assembly code:
B
A=
B =
A
2
1
(= Clock Wise Rotation / Spring to Close)
A
Visual indicator mounted:
(= for Cross line position indication
B
2
2
2
Optional assembly code:
2
21
1
Pistons
A
CC
B
Position
indicator
A
A
2 Spring
(= Counter Clock Wise 1Rotation/
to Open)
2
2
www.emersonprocess.com/bettis
Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained
from our web site www.emersonprocess.com/bettis or from your nearest Valve Automation Center:
America’s: +1 281 477 4100 (fax 477 2809) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 650 14 600 (fax +65 626 80 028)