Saturated C2-C5, Oxygen, Carbon Dioxide, Nitrogen in Methane

Saturated C2-C5, Oxygen, Carbon Dioxide, Nitrogen in Methane
B
C
Page : 1
MATERIAL SAFETY DATA SHEET
Date : 24 / 3 / 2014
Supersedes : 0 / 0 / 0
SATURATED C2-C5, OXYGEN, CARBON DIOXIDE,
NITROGEN IN METHANE
Danger
Revised edition no : 0
AL709
—M
M
«
SECTION 1. Identification of the substance/mixture and of the company/undertaking
1.1. Product identifier
Trade name
SDS Nr
: SATURATED C2-C5, OXYGEN, CARBON DIOXIDE, NITROGEN IN METHANE
: AL709
1.2. Relevant identified uses of the substance or mixture and uses advised against
Relevant identified uses
: Industrial and professional. Perform risk assessment prior to use.
Test gas / Calibration gas. Laboratory use Contact supplier for more uses information
1.3. Details of the supplier of the safety data sheet
Company identification
: Air Liquide Australia Limited
Level 9 / 380 St. Kilda Road
Melbourne VIC 3004 Australia
Tel: + 61 3 9697 9888
Fax: + 61 3 9690 7107
ALAEnquiries@AirLiquide.com
1.4. Emergency telephone number
Emergency telephone number
: 1800 812 588
SECTION 2. Hazards identification
2.1. Classification of the substance or mixture
Hazard Class and Category Code Regulation EC 1272/2008 (CLP)
• Physical hazards
: Flammable gases - Category 1 - Danger - (CLP : Flam. Gas 1) - H220
Gases under pressure - Compressed gas - Warning - (CLP : Press. Gas) - H280
Classification EC 67/548 or EC 1999/45
: F+; R12
2.2. Label elements
Labelling Regulation EC 1272/2008 (CLP)
• Hazard pictograms
• Hazard pictograms code
• Signal word
• Hazard statements
• Precautionary statements
- Prevention
- Response
- Storage
— M
M
«
: GHS02 - GHS04
: Danger
: H220 - Extremely flammable gas.
H280 - Contains gas under pressure; may explode if heated.
: P210 - Keep away from heat, sparks, open flames or hot surfaces. – No smoking.
: P377 - Leaking gas fire: Do not extinguish, unless leak can be stopped safely.
P381 - Eliminate all ignition sources if safe to do so.
: P403 - Store in a well-ventilated place.
2.3. Other hazards
: None.
Air Liquide Australia Limited
Level 9 / 380 St. Kilda Road Melbourne VIC 3004 Australia
Tel: + 61 3 9697 9888
Fax: + 61 3 9690 7107
ALAEnquiries@AirLiquide.com
In case of emergency : 1800 812 588
B
C
Page : 2
MATERIAL SAFETY DATA SHEET
Revised edition no : 0
Date : 24 / 3 / 2014
Supersedes : 0 / 0 / 0
SATURATED C2-C5, OXYGEN, CARBON DIOXIDE,
NITROGEN IN METHANE
AL709
SECTION 2. Hazards identification (continued)
SECTION 3. Composition/information on ingredients
3.1. Substance / 3.2. Mixture
Mixture.
Substance name
Oxygen
:
Contents
<= 1000 PPM
CAS No
7782-44-7
EC No
231-956-9
Annex No
008-001-00-8
*1
O; R8
---------------------------------Ox. Gas 1 (H270)
Press. Gas (H280)
Classification
Carbon dioxide
:
<= 1000 PPM
124-38-9
204-696-9
-----
*1
Not classified (DSD/DPD)
---------------------------------Liq. Gas (H280)
n-Pentane
:
<= 500 PPM
109-66-0
203-692-4
601-006-00-1
-----
F+; R12
Xn; R65
R66
R67
N; R51-53
---------------------------------Flam. Liq. 1 (H224)
Asp. Tox 1 (H304)
STOT RE 3 (H336)
STOT RE (EUH066)
Aquatic Chronic 2 5H411)
Isopentane
:
<= 500 PPM
78-78-4
201-142-8
601-006-00-1
-----
F+; R12
Xn; R65
R66
R67
N; R51-53
---------------------------------Flam. Liq. 1 (H224)
Asp. Tox 1 (H304)
STOT RE 3 (H336)
STOT RE (EUH066)
Aquatic Chronic 2 5H411)
Butane n-
:
<= 0.75 %
106-97-8
203-448-7
601-004-00-0
*2
F+; R12
---------------------------------Flam. Gas 1 (H220)
Liq. Gas (H280)
Isobutane
:
<= 0.75 %
75-28-5
200-857-2
601-004-00-0
*2
F+; R12
---------------------------------Flam. Gas 1 (H220)
Liq. Gas (H280)
Ethane
:
<= 8.5 %
74-84-0
200-814-8
601-002-00-X
*2
F+; R12
---------------------------------Flam. Gas 1 (H220)
Press. Gas (H281)
Propane
:
<= 4 %
74-98-6
200-827-9
601-003-00-5
*2
F+; R12
---------------------------------Flam. Gas 1 (H220)
Liq. Gas (H280)
Nitrogen
:
<= 1 %
7727-37-9
231-783-9
-----
*1
Not classified (DSD/DPD)
---------------------------------Press. Gas (H280)
Methane
:
balance
74-82-8
200-812-7
601-001-00-4
*1
F+; R12
---------------------------------Flam. Gas 1 (H220)
Press. Gas (H280)
Contains no other components or impurities which will influence the classification of the product.
* 1: Listed in Annex IV / V REACH, exempted from registration.
* 2: Registration deadline not expired.
* 3: Registration not required: Substance manufactured or imported < 1t/y
Full text of R-phrases see chapter 16. Full text of H-statements see chapter 16
Air Liquide Australia Limited
Level 9 / 380 St. Kilda Road Melbourne VIC 3004 Australia
Tel: + 61 3 9697 9888
Fax: + 61 3 9690 7107
ALAEnquiries@AirLiquide.com
In case of emergency : 1800 812 588
B
C
Page : 3
MATERIAL SAFETY DATA SHEET
Revised edition no : 0
Date : 24 / 3 / 2014
Supersedes : 0 / 0 / 0
SATURATED C2-C5, OXYGEN, CARBON DIOXIDE,
NITROGEN IN METHANE
AL709
SECTION 4. First aid measures
4.1. Description of first aid measures
- Inhalation
- Skin contact
- Eye contact
- Ingestion
: Remove victim to uncontaminated area wearing self contained breathing apparatus. Keep
victim warm and rested. Call a doctor. Apply artificial respiration if breathing stopped.
: Adverse effects not expected from this product.
: Adverse effects not expected from this product.
: Ingestion is not considered a potential route of exposure.
4.2. Most important symptoms and effects, both acute and delayed
: In high concentrations may cause asphyxiation. Symptoms may include loss of mobility/
consciousness. Victim may not be aware of asphyxiation.
Refer to section 11.
4.3. Indication of any immediate medical attention and special treatment needed
: None.
SECTION 5. Fire-fighting measures
5.1. Extinguishing media
- Suitable extinguishing media
: All known extinguishants can be used.
5.2. Special hazards arising from the substance or mixture
Specific hazards
Hazardous combustion products
: Exposure to fire may cause containers to rupture/explode.
: None that are more toxic than the product itself.
5.3. Advice for fire-fighters
Specific methods
Special protective equipment for fire
fighters
: Do not extinguish a leaking gas flame unless absolutely necessary. Spontaneous/explosive
re-ignition may occur. Extinguish any other fire.
Coordinate fire measure to the surrounding fire. Cool endangered containers with water spray
jet from a protected position. Do not empty contaminated fire water into drains.
If possible, stop flow of product.
: In confined space use self-contained breathing apparatus.
SECTION 6. Accidental release measures
6.1. Personal precautions, protective equipment and emergency procedures
: Evacuate area.
Try to stop release.
Ensure adequate air ventilation.
Eliminate ignition sources.
Consider the risk of potentially explosive atmospheres.
6.2. Environmental precautions
: Try to stop release.
6.3. Methods and material for containment and cleaning up
: Ventilate area.
6.4. Reference to other sections
: See also sections 8 and 13.
Air Liquide Australia Limited
Level 9 / 380 St. Kilda Road Melbourne VIC 3004 Australia
Tel: + 61 3 9697 9888
Fax: + 61 3 9690 7107
ALAEnquiries@AirLiquide.com
In case of emergency : 1800 812 588
B
C
Page : 4
MATERIAL SAFETY DATA SHEET
Revised edition no : 0
Date : 24 / 3 / 2014
Supersedes : 0 / 0 / 0
SATURATED C2-C5, OXYGEN, CARBON DIOXIDE,
NITROGEN IN METHANE
AL709
SECTION 7. Handling and storage
7.1. Precautions for safe handling
Safe use of the product
Safe handling of the gas receptacle
: Take precautionary measures against static discharge.
Purge air from system before introducing gas.
Keep away from ignition sources (including static discharges).
Do not smoke while handling product.
Assess the risk of potentially explosive atmosphere and the need for explosion-proof
equipment.
Consider the use only non-sparking tools.
Use only properly specified equipment which is suitable for this product, its supply pressure
and temperature. Contact your gas supplier if in doubt.
Only experienced and properly instructed persons should handle gases under pressure.
The product must be handled in accordance with good industrial hygiene and safety
procedures.
Ensure the complete gas system was (or is regularily) checked for leaks before use.
: Refer to supplier's container handling instructions.
Do not allow backfeed into the container.
Protect cylinders from physical damage; do not drag, roll, slide or drop.
When moving cylinders, even for short distances, use a cart (trolley, hand truck, etc.)
designed to transport cylinders.
Leave valve protection caps in place until the container has been secured against either a wall
or bench or placed in a container stand and is ready for use.
If user experiences any difficulty operating cylinder valve discontinue use and contact
supplier.
Never attempt to repair or modify container valves or safety relief devices.
Damaged valves should be reported immediately to the supplier.
Keep container valve outlets clean and free from contaminates particularly oil and water.
Replace valve outlet caps or plugs and container caps where supplied as soon as container is
disconnected from equipment.
Close container valve after each use and when empty, even if still connected to equipment.
Never attempt to transfer gases from one cylinder/container to another.
Never use direct flame or electrical heating devices to raise the pressure of a container.
Do not remove or deface labels provided by the supplier for the identification of the cylinder
contents.
7.2. Conditions for safe storage, including any incompatibilities
: Segregate from oxidant gases and other oxidants in store.
All electrical equipment in the storage areas should be compatible with the risk of potentially
explosive atmosphere.
Keep away from combustible materials.
Keep container below 50°C in a well ventilated place.
Observe all regulations and local requirements regarding storage of containers.
Containers should not be stored in conditions likely to encourage corrosion.
Containers should be stored in the vertical position and properly secured to prevent toppling.
Stored containers should be periodically checked for general condition and leakage.
Container valve guards or caps should be in place.
Store containers in location free from fire risk and away from sources of heat and ignition.
7.3. Specific end use(s)
: None.
SECTION 8. Exposure controls/personal protection
8.1. Control parameters
Occupational Exposure Limits
Butane n-
:
:
:
:
:
MAK (AU) Tagesmittelwert (ml/m³) : 800
MAK (AU) Kurzzeitwerte (mg/m³) : 3800
MAK (AU) Tagesmittelwert (mg/m³) : 1900
MAK (AU) Kurzzeitwerte (ml/m³) : 1600
TLV© -TWA [ppm] : 800
Air Liquide Australia Limited
Level 9 / 380 St. Kilda Road Melbourne VIC 3004 Australia
Tel: + 61 3 9697 9888
Fax: + 61 3 9690 7107
ALAEnquiries@AirLiquide.com
In case of emergency : 1800 812 588
B
C
Page : 5
MATERIAL SAFETY DATA SHEET
Revised edition no : 0
Date : 24 / 3 / 2014
Supersedes : 0 / 0 / 0
SATURATED C2-C5, OXYGEN, CARBON DIOXIDE,
NITROGEN IN METHANE
AL709
SECTION 8. Exposure controls/personal protection (continued)
Propane
Isobutane
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
LTEL - UK [ppm] : 600
STEL - UK [mg/m³] : 750
VME - France [mg/m³] : 1900
VME - France [ppm] : 800
AGW (8h) - Germany [mg/m³] TRGS 900 : 2400
AGW (8h) - Germany [ppm] TRGS 900 : 1000
Exceeding factor AGW - Germany TRGS 900 : 4
VLA-ED - Spain [ppm] : 1000
Grænserværdier (DK) (ppm) : 500
HTP-värden (FI) - 8 H - [ppm] : 800
HTP-värden (FI) - 8 H - [mg/m³] : 1900
HTP-värden - 15min - [ppm] : 1000
Grænserværdier (DK) : 1200
HTP-värden - 15min - [mg/m³] : 2400
GV Value Limit (Norway) [ppm] : 250
GV Value Limit (Norway) [mg/m³] : 600
TLV-TWA (Belgium) (ppm) : 800
MAK (AU) Tagesmittelwert (ml/m³) : 1000
MAK (AU) Tagesmittelwert (mg/m³) : 1800
MAK (AU) Kurzzeitwerte (mg/m³) : 3600
MAK (AU) Kurzzeitwerte (ml/m³) : 2000
TLV© -TWA [ppm] : 2500
AGW (8h) - Germany [mg/m³] TRGS 900 : 1000
AGW (8h) - Germany [ppm] TRGS 900 : 1800
Exceeding factor AGW - Germany TRGS 900 : 4
VLA-ED - Spain [ppm] : 1000
Grænserværdier (DK) (ppm) : 1000
HTP-värden (FI) - 8 H - [ppm] : 800
HTP-värden (FI) - 8 H - [mg/m³] : 1500
HTP-värden - 15min - [ppm] : 1100
Grænserværdier (DK) : 1800
HTP-värden - 15min - [mg/m³] : 2000
GV Value Limit (Norway) [ppm] : 500
GV Value Limit (Norway) [mg/m³] : 900
8-Hour TWA (PL) (NDS) (mg/m³) : 1800
LTEL - UK [ppm] : 500
STEL - UK [ppm] : 750
MAK (AU) Tagesmittelwert (ml/m³) : 800
MAK (AU) Kurzzeitwerte (mg/m³) : 3800
MAK (AU) Tagesmittelwert (mg/m³) : 1900
MAK (AU) Kurzzeitwerte (ml/m³) : 1600
TLV© -TWA [ppm] : 800
AGW (8h) - Germany [mg/m³] TRGS 900 : 2400
AGW (8h) - Germany [ppm] TRGS 900 : 1000
Exceeding factor AGW - Germany TRGS 900 : 4
HTP-värden (FI) - 8 H - [ppm] : 800
HTP-värden (FI) - 8 H - [mg/m³] : 1900
HTP-värden - 15min - [ppm] : 1000
HTP-värden - 15min - [mg/m³] : 2400
Air Liquide Australia Limited
Level 9 / 380 St. Kilda Road Melbourne VIC 3004 Australia
Tel: + 61 3 9697 9888
Fax: + 61 3 9690 7107
ALAEnquiries@AirLiquide.com
In case of emergency : 1800 812 588
B
C
Page : 6
MATERIAL SAFETY DATA SHEET
Revised edition no : 0
Date : 24 / 3 / 2014
Supersedes : 0 / 0 / 0
SATURATED C2-C5, OXYGEN, CARBON DIOXIDE,
NITROGEN IN METHANE
AL709
SECTION 8. Exposure controls/personal protection (continued)
Carbon dioxide
DNEL: Derived no effect level
PNEC: Predicted no effect
concentration
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
Value 8h (CZ) [mg/m3] : 9000
ILV (EU) - 8 H - [mg/m³] : 9000
ILV (EU) - 8 H - [ppm] : 5000
TLV© -TWA [ppm] : 5000
TLV© -STEL [ppm] : 30000
AGW (8h) - Germany [mg/m³] TRGS 900 : 9100
AGW (8h) - Germany [ppm] TRGS 900 : 5000
MAK (AU) Tagesmittelwert (ml/m³) : 5000
MAK (AU) Tagesmittelwert (mg/m³) : 9000
MAK (AU) Kurzzeitwerte (ml/m³) : 10000
MAK (AU) Kurzzeitwerte (mg/m³) : 18000
VLA-ED - Spain [ppm] : 5000
VLA-ED - Spain [mg/m3] : 9150
VLA-EC - Spain [ppm] : 15000
VLA-EC - Spain [mg/m3] : 27400
NGV - [ppm] : 5000
NGV - [mg/m³] : 9000
KTV - [ppm] : 10
KTV - [mg/m³] : 10
HTP-värden (FI) - 8 H - [ppm] : 5000
HTP-värden (FI) - 8 H - [mg/m³] : 9100
Grænserværdier (DK) (ppm) : 5000
Grænserværdier (DK) (ppm) : 9000
Grænserværdier (DK) : 9000
GV Value Limit (Norway) [ppm] : 5000
GV Value Limit (Norway) [mg/m³] : 9000
8-Hour TWA (PL) (NDS) (mg/m³) : 9000
15-Minute STEL (PL)(NDSCh) (mg/m³) : 27000
Valori Limite di Soglia (IT) 8 ore [ppm] : 5000
Valori Limite di Soglia (IT) 8 ore [mg/m3] : 9000
TLV-TWA (Belgium) (ppm) : 5000
TLV-STEL (Belgium) (ppm) : 30000
Value 15min. (CZ) [mg/m3] : 45000
None available.
None available.
8.2. Exposure controls
: Systems under pressure shoud be regularily checked for leakages.
Provide adequate general and local exhaust ventilation.
Gas detectors should be used when flammable gases/vapours may be released.
Keep concentrations well below lower explosion limits.
Ensure exposure is below occupational exposure limits (where available).
Consider work permit system e.g. for maintenance activities.
8.2.2. Individual protection measures, : Consider the use of flame resistant anti-static safety clothing.
A risk assessment should be conducted and documented in each work area to assess the
e.g. personal protective equipment
risks related to the use of the product and to select the PPE that matches the relevant risk.
The following recommendations should be considered.
Wear safety glasses with side shields
Wear leather safety gloves and safety shoes when handling cylinders.
: Refer to local regulations for restriction of emissions to the atmosphere. See section 13 for
8.2.3. Environmental exposure
specific methods for waste gas treatment.
controls
8.2.1. Appropriate engineering
controls
Air Liquide Australia Limited
Level 9 / 380 St. Kilda Road Melbourne VIC 3004 Australia
Tel: + 61 3 9697 9888
Fax: + 61 3 9690 7107
ALAEnquiries@AirLiquide.com
In case of emergency : 1800 812 588
B
C
Page : 7
MATERIAL SAFETY DATA SHEET
Revised edition no : 0
Date : 24 / 3 / 2014
Supersedes : 0 / 0 / 0
SATURATED C2-C5, OXYGEN, CARBON DIOXIDE,
NITROGEN IN METHANE
AL709
SECTION 9. Physical and chemical properties
9.1. Information on basic physical and chemical properties
Appearance
- Physical state at 20°C / 101.3kPa
- Colour
Odour
Odour threshold
pH value
Molar mass [g/mol]
Melting point [°C]
Boiling point [°C]
Flash point [°C]
Evaporation rate (ether=1)
Flammability range [vol% in air]
Vapour pressure [20°C]
Relative density, gas (air=1)
Solubility in water [mg/l]
Partition coefficient n-octanol/water
Viscosity at 20°C [mPa.s]
Explosive Properties
:
:
:
:
Gas.
Colourless gas.
Hydrocarbon.
Odour threshold is subjective and inadequate to warn for overexposure.
: Not applicable for gases and gas-mixtures.
: Not applicable for gas-mixtures.
: Not applicable for gas-mixtures.
: Not applicable for gas-mixtures.
:
Not applicable.
: Lighter or similar to air.
: Not known, but considered to have low solubility.
:
Not applicable for gas-mixtures.
: Not applicable.
: Not applicable.
9.2. Other information
Other data
: None.
SECTION 10. Stability and reactivity
10.1. Reactivity
: No reactivity hazard other than the effects described in sub-sections below.
10.2. Chemical stability
: Stable under normal conditions.
10.3. Possibility of hazardous reactions
: May react violently with oxidants.
Can form explosive mixture with air.
10.4. Conditions to avoid
: Keep away from heat/sparks/open flames/hot surfaces. – No smoking.
10.5. Incompatible materials
: May react violently with combustible materials.
10.6. Hazardous decomposition products
: Under normal conditions of storage and use, hazardous decomposition products should not
be produced.
Air Liquide Australia Limited
Level 9 / 380 St. Kilda Road Melbourne VIC 3004 Australia
Tel: + 61 3 9697 9888
Fax: + 61 3 9690 7107
ALAEnquiries@AirLiquide.com
In case of emergency : 1800 812 588
B
C
Page : 8
MATERIAL SAFETY DATA SHEET
Revised edition no : 0
Date : 24 / 3 / 2014
Supersedes : 0 / 0 / 0
SATURATED C2-C5, OXYGEN, CARBON DIOXIDE,
NITROGEN IN METHANE
AL709
SECTION 11. Toxicological information
11.1. Information on toxicological effects
Acute toxicity
Rat inhalation LC50 [ppm/4h]
Skin corrosion/irritation
Serious eye damage/irritation
Respiratory or skin sensitisation
Carcinogenicity
Germ cell mutagenicity
Toxic for reproduction : Fertility
Toxic for reproduction : unborn child
STOT-single exposure
STOT-repeated exposure
Aspiration hazard
:
:
:
:
:
:
:
:
:
:
:
:
No known toxicological effects from this product.
No data available.
No known effects from this product.
No known effects from this product.
No known effects from this product.
No known effects from this product.
No known effects from this product.
No known effects from this product.
No known effects from this product.
No known effects from this product.
No known effects from this product.
Not applicable for gases and gas-mixtures.
SECTION 12. Ecological information
12.1. Toxicity
: No data available.
12.2. Persistence - degradability
: No data available.
12.3. Bioaccumulative potential
: No data available.
12.4. Mobility in soil
: No data available.
12.5. Results of PBT and vPvB assessment
: No data available.
12.6. Other adverse effects
Effect on ozone layer
Effect on the global warming
: None.
: Contains greenhouse gas(es) not covered by 842/2006/EC
SECTION 13. Disposal considerations
13.1. Waste treatment methods
: Do not discharge into areas where there is a risk of forming an explosive mixture with air.
Waste gas should be flared through a suitable burner with flash back arrestor.
Do not discharge into any place where its accumulation could be dangerous.
Ensure that the emission levels from local regulations or operating permits are not exceeded.
Refer to the code of practice of EIGA (Doc. 30/10 “Disposal of Gases, downloadable at http://
www.eiga.org) for more guidance on suitable disposal methods
Contact supplier if guidance is required.
13.2. Additional information
: None.
Air Liquide Australia Limited
Level 9 / 380 St. Kilda Road Melbourne VIC 3004 Australia
Tel: + 61 3 9697 9888
Fax: + 61 3 9690 7107
ALAEnquiries@AirLiquide.com
In case of emergency : 1800 812 588
B
C
Page : 9
MATERIAL SAFETY DATA SHEET
Revised edition no : 0
Date : 24 / 3 / 2014
Supersedes : 0 / 0 / 0
SATURATED C2-C5, OXYGEN, CARBON DIOXIDE,
NITROGEN IN METHANE
AL709
SECTION 14. Transport information
UN number
Labelling ADR, IMDG, IATA
: 1954
ó
m
: 2.1 : flammable gas.
Land transport (ADR/RID)
H.I. nr
UN proper shipping name
Transport hazard class(es)
Classification code
Packing Instruction(s)
Tunnel Restriction
HAZCHEM - Emergency Action Code
:
:
:
:
:
:
:
23
COMPRESSED GAS, FLAMMABLE, N.O.S. (Methane, Ethane)
2
1F
P200
B/D Tank carriage: Passage forbidden through tunnels of category B, C, D
2SE
2 = Fine water spray.
S = Risk of violent reaction or explosion. Recommended personal protective equipment : Full
fire kit and breathing apparatus. Appropriate measures : dilute.
E = There may be a public safety hazard outside the immediate area of the incident, and that
the following actions should be considered :
1. People should be warned to stay indoors with all doors and windows closed, preferably in
rooms upstairs and facing away from the incident. Ignition sources should be eliminated and
any ventilation stopped.
2. Effects may spread beyond the immediate vicinity. all non-essential personnel should be
instructed to move at least 250 metres away from the incident.
3. Police and fire brigade incident commanders should consult each other and with a product
expert, or with a source of product expertise.
4. The possible need for subsequent evacuation should be considered, but it should be
remembered that in most cases it will be safer to remain in a building than to evacuate.
:
:
:
:
:
COMPRESSED GAS, FLAMMABLE, N.O.S. (Methane, Ethane)
2.1
F-D
S-U
P200
:
:
:
:
:
COMPRESSED GAS, FLAMMABLE, N.O.S. (Methane, Ethane)
2.1
DO NOT LOAD IN PASSENGER AIRCRAFT.
Allowed.
200
Sea transport (IMDG)
Proper shipping name
Class
Emergency Schedule (EmS) - Fire
Emergency Schedule (EmS) - Spillage
Packing instruction
Air transport (ICAO-TI / IATA-DGR)
Proper shipping name (IATA)
Class
Passenger and Cargo Aircraft
Cargo Aircraft only
Packing instruction - Cargo Aircraft
only
Special precautions for user
: Avoid transport on vehicles where the load space is not separated from the driver's
compartment.
Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the
event of an accident or an emergency.
Before transporting product containers :
- Ensure there is adequate ventilation.
- Ensure that containers are firmly secured.
- Ensure cylinder valve is closed and not leaking.
- Ensure valve outlet cap nut or plug (where provided) is correctly fitted.
- Ensure valve protection device (where provided) is correctly fitted.
Air Liquide Australia Limited
Level 9 / 380 St. Kilda Road Melbourne VIC 3004 Australia
Tel: + 61 3 9697 9888
Fax: + 61 3 9690 7107
ALAEnquiries@AirLiquide.com
In case of emergency : 1800 812 588
B
C
Page : 10
MATERIAL SAFETY DATA SHEET
Revised edition no : 0
Date : 24 / 3 / 2014
Supersedes : 0 / 0 / 0
SATURATED C2-C5, OXYGEN, CARBON DIOXIDE,
NITROGEN IN METHANE
AL709
SECTION 15. Regulatory information
15.1. Safety, health and environmental regulations/legislation specific for the substance or mixture
EU legislation
Seveso directive 96/82/EC
: Covered
National legislation
: Ensure all national/local regulations are observed.
15.2. Chemical Safety Assessment
: A CSA does not need to be carried out for this product.
SECTION 16. Other information
: Revised safety data sheet in accordance with commisssion regulation (EU) No 453/2010
: Ensure operators understand the flammability hazard.
Receptacle under pressure.
:
R8
: Contact with combustible material may cause fire.
List of full text of R-phrases in section
R12 : Extremely flammable.
3.
R51/53 : Toxic to aquatic organisms, may cause long-term adverse effects in the aquatic
environment.
R65 : Harmful : may cause lung damage if swallowed.
R66 : Repeated exposure may cause skin dryness or cracking.
R67 : Vapours may cause drowsiness and dizziness.
: EUH066 - Repeated exposure may cause skin dryness or cracking.
List of full text of H-statements in
H220 - Extremely flammable gas.
section 3.
H224 - Extremely flammable liquid and vapour.
H270 - May cause or intensify fire; oxidizer.
H280 - Contains gas under pressure; may explode if heated.
H281 - Contains refrigerated gas; may cause cryogenic burns or injury.
H304 - May be fatal if swallowed and enters airways.
H336 - May cause drowsiness or dizziness.
H411 - Toxic to aquatic life with long lasting effects.
: Classification in accordance with calculation methods of regulation (EC) 1272/2008 CLP / (
Further information
EC) 1999/45 DPD.
This Safety Data Sheet has been established in accordance with the applicable European
Union legislation.
: Before using this product in any new process or experiment, a thorough material compatibility
DISCLAIMER OF LIABILITY
and safety study should be carried out.
Details given in this document are believed to be correct at the time of going to press. Whilst
proper care has been taken in the preparation of this document, no liability for injury or
damage resulting from its use can be accepted.
Indication of changes
Training advice
The contents and format of this SDS are in accordance with EC Commission Directive 2001/58/EC.
DISCLAIMER OF LIABILITY The information in this SDS was obtained from sources which we believe are reliable. However, the
information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of
handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other
reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way
connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this
product. If the product is used as a component in another product, this MSDS information may not be applicable.
End of document
Air Liquide Australia Limited
Level 9 / 380 St. Kilda Road Melbourne VIC 3004 Australia
Tel: + 61 3 9697 9888
Fax: + 61 3 9690 7107
ALAEnquiries@AirLiquide.com
In case of emergency : 1800 812 588
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising