Halsey Taylor HCRFER.A Water Coolers-Drinking Fountain Owner Manual
Halsey Taylor HCRFER.A is a refrigerated fountain with a back panel that can be used to provide chilled drinking water in various settings. It features a remote chiller that can be conveniently placed to save space and reduce noise, while the fountain itself can be mounted on a wall or frame for easy access. The fountain has a push-button activation and a bubbler that delivers a steady stream of chilled water. It also includes a drain tube for easy disposal of excess water. With its durable construction and user-friendly design, the Halsey Taylor HCRFER.
Advertisement
Advertisement
HCRFERQ - A
Halsey Taylor Owners Manual
Refrigerated Fountain with Back Panel
HCRF - ER
Installer
To assure you install this model easily and correctly,
PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE
INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH
PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave these instructions inside the fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK
INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN
INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING
THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER
SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING
PLUMBING SYSTEM.
1/4" O.D. TUBE
WATER INLET
TO COOLER
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY
BUILDING WATER INLET
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS
SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
FIG. 1
NOTE: WATER FLOW
DIRECTION SERVICE STOP
(NOT FURNISHED)
FIG. 2
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
97806C (Rev. A - 04/02)
HCRFERQ - A
HCRF-ER ROUGH-IN
LEGEND:
A = 3/8" O.D. TUBE WATER OUTLET
B = 3/8" O.D. TUBE WATER INLET
C = 1-1/4" O.D. WASTE TUBE (INCLUDED)
D = ELECTRICAL INLET
97806C (Rev. A - 04/02)
FIG. 3
PAGE 2
HCRFERQ - A
HCRF - ER COOLER INSTALLATION
1. Install remote chiller. Remove front panel of chiller. Remove and discard cardboard inner pack from between compressor and
side panel. Slide chiller onto the shelf and position it to the left within the guides on the shelf.
NOTE: Building construction must allow for adequate air flow on both sides, top, and back of chiller. A minimum of 4" (102mm) on
both sides and top are required. See chiller instructions for additional instructions.
2. Make water supply connections. Attach an uplated copper water inlet line and service stop (not provided) to the chiller.
Inlet port is marked on the chiller (3/8" O.D. copper tube). Bend the copper tube (provided) at an appropriate length from chiller
to opening in frame. Install a 3/8" O.D. tube union fitting (provided) on the marked chiller outlet port. Turn on the water supply
and flush the line thoroughly.
3. Hang the upper panel on the mounting frame hanger. Align holes in the panel with the holes in the mounting frame.
Be sure that panel is engaged with hanger at top of frame before releasing it.
4. Install the fountain. Remove access cover plate on underside of fountain and save the screws. Mount the fountain to the
upper panel and the wall frame with (4) 5/16" x 3/4" (19mm) long bolts and nuts (provided). Tighten securely.
5. Insert waste tube (provided) into drain on fountain. Attach waste tube (1 1/4" O.D.) to 1 1/4" O.D. slip trap (provided by others).
6. Make connections between remote chiller outlet tube and fountain strainer. Insert the water inlet line into inlet side
of strainer by pushing it in until it reaches a positive stop, approximately 3/4" (19mm). Turn on the water supply and check
for leaks. DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO THE O-RINGS MAY RESULT.
7. These products are designed to operate on 20-105 PSIG supply line pressure. If inlet pressure is above 105 PSIG, a
pressure regulator must be installed in the supply line. Any damage caused by reason of connecting these products to supply line
pressures lower than 20 PSIG or higher than 105 PSIG is not covered by warranty.
8. Make electrical connections to the chiller. See chiller instructions.
9. Check stream height from bubbler. Stream height is factory set at 45-50 PSI. If supply pressure varies greatly from this,
remove items 3 & 4 and adjust the screw on regulator (Item 8). Clockwise adjustment will raise stream height and counter-
clockwise will lower stream height. For best adjustment stream height should be approximately 1 1/2" (38mm)above the
bubbler guard. (See Figure 6)
10. Mount lower panel. Loosen the (2) #10-24 x 5/8" (16mm) screws at frame bottom lip. Slide upper tongue of lower panel under
lower edge of already installed upper panel. Tighten previously loosened screws securely.
11. Replace bottom access panel to fountain basin using screws provided. Tighten securely.
TROUBLE SHOOTING AND MAINTENANCE
1. Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed
from orifice with a small round file not over 1/8" diameter or a small diameter wire.
CAUTION: Do not file or cut orifice materials.
2. Stream Regulator: If orifice is clean, regulate flow as in "START UP" instructions. If replacement is necessary, see parts
list for correct regulator part number.
3. Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an o-ring water
seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing (See Fig. 2)
To insert tubing, push tube straight into the fitting until it reaches a positive stop, approximately 3/4".
TO BUBBLER
HCRF - ER
TUBE ROUTING
11
20
19
CHILLER
OUTLET
CHILLER
INLET
FIG. 4
PAGE 3 97806C (Rev. A - 04/02)
ITEM NO.
25
26
27
28
29
NS
NS
21
22
23
24
17
18
19
20
13
14
15
16
9
10
11
12
7
8
5
6
3
4
1
2
PART NO.
45716C
15005C
45662C
45737C
50986C
51544C
15008C
61313C
70022C
110711942550
55996C
55001130
55000665
28280C
40045C
70055C
28291C
28281C
70745C
70870C
56092C
62095C
45717C
45728C
75588C
75589C
50074C
100322740560
45736C
111577243890
111577343890
PARTS LIST
DESCRIPTION
Drain
Retaining Nut
Push Button
Push Button Sleeve
Regulator Holder
Bubbler Assy
Bubbler - Nipple
Regulator
Setscrew - #6-32 x .31"
Screw - #8-32 x .38" TH
Strainer
Fountain Arm
Bottom Cover Plate
Back Panel
Hex Nut
Speed Nut
Regulator Mounting Bracket
Lower Panel
Union - 3/8 x 1/4
Union - 3/8 x 3/8
Poly Tubing (Cut To Length)
Tube - Water In
Drain Tube
Drain Ferrule
Nut - Slip Joint
Washer - Seal
Gasket - Tail Pipe
Gasket
Nut-Regulator Mounting
Screw - Mach 5/16-18 x 3/4
Nut - Hex 5/16-18
HCRFERQ - A
FIG. 5
FIG. 6
3 4
9
15 2
17
8 29 5
6
28
7
FIG. 7
FIG. 8
7
6
12
21
SEE FIG. 6
SEE FIG. 5
11
22
10, 13, 16 1, 24, 25, 26, 27 23
2222 CAMDEN COURT
OAK BROOK, IL 60523
630.574.3500
97806C (Rev. A - 04/02)
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
PAGE 4
14
18
PRINTED IN U.S.A.

Public link updated