Heating
EHPT15-30X-UKHCW
FTC5 Pre-plumbed Standard Cylinders
for Ecodan Monobloc Units
Energy
Monitoring
NOW
INCLUDED
Pre-plumbed space
heating and domestic
hot water cylinder for
Ecodan monobloc air
source heat pumps
The pre-plumbed standard cylinder comes complete
with integrated hydraulic components and advanced
controls.
Designed to integrate with the Ecodan monobloc air source
heat pump range, the standard cylinder provides improved
performance and faster heat up times through the use of
plate heat exchanger technology. Fast commissioning via an
SD card and energy monitoring functions are now included.
Key Features
Simple graphical control
Optional 2-zone energy efficient space heating control
Compatible with Mitsubishi Electric wireless room controllers
Pre-plumbed and wired for faster installation
Hybrid function, for use with conventional boilers
SD card commissioning
Energy monitoring as standard
Product Information
Heating
EHPT15-30X-UKHCW
FTC5 Pre-plumbed Standard Cylinders
for Ecodan Monobloc Units
AdvAnCEd ConTrollEr – WiTH EnErgy MoniToring
Mitsubishi Electric’s fifth generation controller (FTC5) includes intelligent room temperature control as standard.
This together with advanced weather compensation ensures the system delivers efficient, comfortable heating
regardless of the season. FTC5 now also includes energy monitoring showing consumed and produced energy.
CylindEr
EHPT15X-UKHCW EHPT17X-UKHCW EHPT21X-UKHCW EHPT25X-UKHCW EHPT30X-UKHCW
NOMINAL HOT WATER VOLUME (LITRES)
ErP RATING
HEAT LOSS (kWh/24hrs)
HEAT LOSS (W)
WATER
Flow Rate (l/min) W50 - W85 - W112 - HW140
Primary Pump
Sanitary Hot Water Pump
WATER SAFETY
DEVICES
Water Circuit
DHW Cylinder
DIMENSIONS (mm)
WEIGHT EMPTY / FULL (kg)
CYLINDER MATERIAL Cylinder
Insulation
ELECTRICAL DATA
Control Board
optionally
powered by
outdoor unit
Immersion
Heater
210
C
1.57
65.4
14.3 - 25.8 - 32.1 - 40.1
2 x Grundfos UPS2 25-60
170
B
1.32
55.0
150
B
1.19
49.6
Connection Size (mm) Heating / DHW (mm)
Primary Expansion Vessel (Litres)
Charge Pressure (MPa (Bar))
Control Thermistor (°C)
Pressure Relief Valve (MPa (Bar))
Expansion Relief Valve (Cold)
Control Thermistor
High Limit Stat (°C)
Temp and Pressure Relief Valve (°C) / (MPa (Bar))
Width
Depth
Height
Cylinder Material
Insulation Type
Insulation Thickness (mm)
Standing Heat Loss (kWh/24hrs)
GWP of Insulation
ODP of Insulation
Electrical Supply
Phase
Fuse Rating - MCB Sizes (A)*1
Electrical Supply
Phase
Capacity (kW)
Max Running Current (A)
Fuse Rating - MCB Sizes (A)*1
300
C
1.89
78.8
250
C
1.67
69.6
22
12
0.35 (3.5)
1 - 80
0.3 (3)
0.8 (8)
40-70
Mechanical 80
90 / 1.0 (10)
712
691
1113
56 / 206
Stainless Steel
Grundfos UPSO 15-60 CIL2
22
22
22
24
18
18
0.35 (3.5)
0.35 (3.5)
0.35 (3.5)
1 - 80
1 - 80
1 - 80
0.3 (3)
0.3 (3)
0.3 (3)
0.8 (8)
0.8 (8)
0.8 (8)
40-70
40-70
40-70
Mechanical 80
Mechanical 80
Mechanical 80
90 / 1.0 (10)
90 / 1.0 (10)
90 / 1.0 (10)
712
712
712
691
691
691
1743
1491
1239
77 / 327
69 / 279
62 / 232
Stainless Steel
Stainless Steel
Stainless Steel
CFC / HCFC-free flame-retardant expanded Polyurethane
22
24
0.35 (3.5)
1 - 80
0.3 (3)
0.8 (8)
40-70
Mechanical 80
90 / 1.0 (10)
712
691
2057
87 / 387
Stainless Steel
60
1.19
3.1
0
220-240v, 50Hz
Single
10
220-240v, 50Hz
Single
3
13
16
60
1.32
3.1
0
220-240v, 50Hz
Single
10
220-240v, 50Hz
Single
3
13
16
60
1.67
3.1
0
220-240v, 50Hz
Single
10
220-240v, 50Hz
Single
3
13
16
60
1.89
3.1
0
220-240v, 50Hz
Single
10
220-240v, 50Hz
Single
3
13
16
MECHANICAL ZONES
OPTIONAL SIMPLIFIED WIRELESS ROOM THERMOSTAT AND WIRELESS RECEIVER
60
1.57
3.1
0
220-240v, 50Hz
Single
10
220-240v, 50Hz
Single
3
13
16
DHW and 1 Heating Zone*2
PAR-WT50-E Controller and PAR-WR51-E Receiver
Cylinder includes: Flow Temperature Controller (FTC5) with Main Controller and Temperature Sensors, Magnetic & Cyclonic Filter, Pumps & Valves for Zone 1 and DHW use, Flow Sensor, Plate Heat Exchanger, Scale Trap, 3kW Immersion Heater and Expansion Vessel.
*1 MCB Sizes BS EN60898-2 & BS EN60947-2 *2 Optional 2 zone accessory pack available
diMEnSionS
580
Side View
Upper View
OVERALL HEIGHT
691
Front View
712
Model
1113
EHPT17X-UKHCW
1239
EHPT21X-UKHCW
1491
EHPT25X-UKHCW
1743
EHPT30X-UKHCW
2057
Telephone: 01707 282880
email: [email protected] web: heating.mitsubishielectric.co.uk
UNITED KINGDOM Mitsubishi Electric Europe Living Environmental Systems Division
Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, England General Enquiries Telephone: 01707 282880 Fax: 01707 278881
IRELAND Mitsubishi Electric Europe Westgate Business Park, Ballymount, Dublin 24, Ireland
Telephone: Dublin (01) 419 8800 Fax: Dublin (01) 419 8890 International code: (003531)
Country of origin: United Kingdom – Japan – Thailand – Malaysia. ©Mitsubishi Electric Europe 2015. Mitsubishi and Mitsubishi Electric are trademarks of Mitsubishi Electric Europe B.V. The company reserves the
right to make any variation in technical specification to the equipment described, or to withdraw or replace products without prior notification or public announcement. Mitsubishi Electric is constantly developing
and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All goods are supplied subject to
the Company’s General Conditions of Sale, a copy of which is available on request. Third-party product and brand names may be trademarks or registered trademarks of their respective owners.
Printed in August 2015 SAP No. 282530
overall Height
EHPT15X-UKHCW
*All dimensions in mm
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement