PROFIBUS DP Scanner Features For the Allen-Bradley PLC-5 Controller

PROFIBUS DP Scanner  Features For the Allen-Bradley PLC-5 Controller
The BradCommunications™ SST™ PROFIBUS® scanner
connects your Allen-Bradley® PLC-5® controller to
PROFIBUS DP.
PROFIBUS DP Scanner
Features
• BradCommunications SST
For the Allen-Bradley PLC-5 Controller
PROFIBUS DP Master Configuration
Software
•
Supports all standard PROFIBUS
baud rates (up to 12 Mbaud)
•
Simultaneous operation of
PROFIBUS DP Master and Slave
•
Flash memory for storage of
DP Master I/O configuration
•
Fast, easy set up into PLC-5
backplane, PROFIBUS I/O data is
automatically transferred into the
PLC-5 processor’s integer (N) files
of choice
•
Supports exported configuration
files from the BradCommunications
SST DP configuration software
Protocols
• PROFIBUS DP Master V0-Class 1&2
•
Overview
The BradCommunications SST PROFIBUS scanner connects your
Allen-Bradley PLC-5 controller to PROFIBUS as a master or slave to scan or
emulate PROFIBUS DP I/O.
PROFIBUS DP Slave V0
Typical Applications
• Process application, e.g. waste
water treatment
• Real-time control in steel industry
• Brewery applications
The BradCommunications SST PROFIBUS scanner fastens onto the side of any
PLC-5 processor that supports a side car and functions with the Allen-Bradley
PLC-5 as a co-processor.
A 9-pin serial port included on the scanner provides for firmware upgrades in the
field and the upload of I/O configurations.
The PLC-5 processor logic scan and the PROFIBUS I/O scan are independent of
each other. The PLC-5 processor reads the scanner input data during its input
scan and writes the output data during its output scan. The scanner continues
reading input data from the slaves and writing output data to the slaves
independent of what the PLC-5 is doing. Slave status, diagnostic status
information on all slaves, network diagnostic counters and DP Master diagnostic
counters are maintained by the scanner.
PROFIBUS® DP Scanner
Diagnostic & Software Tools
BradCommunications™ SST™
Configuration Software
• Browse your DP network for slave
devices you want to include in your
DP Master configuration using the
DPView component
Scanner Software
•
•
Maintains slave status, diagnostic
status information on all slaves,
network diagnostic counters, and
DP Master diagnostic counters
Maintains network and I/O module
status information including:
• Active Slave Station Bit table
• Configured Slave Station Bit
table
• Network diagnostic counters
• DP Master diagnostic counters
Diagnostic LEDs
•
COMM, SYS and OK LEDs provide
immediate notification of network
and system errors
Other PROFIBUS® Products
•
PROFIBUS modules for
Allen-Bradley® ControlLogix® and
SLC™ 500
•
PROFIBUS network interface cards
(PCI, C-PCI, PC/104, ISA, VME64,
PCMCIA) with many user interfaces
(DLL, OPC, ActiveX…)
•
PROFIBUS gateways to ASi, Serial
and Ethernet networks
•
IP67 PROFIBUS I/O modules
(M8/M12 connectors)
•
Full metal PROFIBUS connector
•
•
•
IDC-technique provides quick
and error-free connection
Optional diagnostic LED
reduces downtime
PROFIBUS media
•
Cable, cordsets, receptacles
Network Specifications
Protocol
LAN Controller
Slaves Supported
I/O per Slave
I/O Mapping
®
(for PLC-5 )
•
•
•
•
•
•
•
•
•
Cable
•
•
•
Connector
•
Data Rate
PROFIBUS DP Master V0, class 1&2
PROFIBUS DP Slave V0
Siemens ASPC2
Maximum of 125
Maximum of 244 bytes in/out
Choose integer file (N) in PLC-5 for all card inputs
Choose a different integer file (N) for all card outputs
Maximum 1000 words in, 1000 words out
Mapping depends on the addresses assigned in the
configuration you create
All standard PROFIBUS data rates up to 12 Mbps
Belden 3079A
™
®
BradConnectivity Brad Harrison 85-0001
PVR2 conductor with shield, UL-listed
DB9 female connector
Hardware Specifications
Bus Interface
Processor
Memory
Diagnostics
Backplane
Current Consumption
Operating Temperature
Storage Temperature
Relative Humidity
Allen-Bradley PLC-5
Intel i960
512 KB of local i960 RAM
256 KB of onboard shared memory
512 KB of sectored flash memory
for storage of program and configuration data
Three LEDs indicate:
1. health of the PROFIBUS network (COMM)
2. communication status with PROFIBUS slaves (SYS)
3. that initialization is complete and the module is ok
(OK)
1.5A @ 5V from a supply delivering Separated Extra Low
Voltage (SELV)
0ºC (32ºF) up to +70ºC (158ºF)
-25ºC (-13°F) up to +70ºC (158°F)
5% to 95% non-condensing
Ordering Information
Part Number
Description
SST-PFB-PLC5
PROFIBUS Scanner for Allen-Bradley PLC-5
SST-PFB-CLX-RLL
PROFIBUS Scanner for Allen-Bradley ControlLogix,
includes Remote Link Library
SST-PFB-SLC
PROFIBUS Scanner for SLC 500 series
APP-ESP-GTW
Gateway for PROFIBUS to serial/Ethernet
SST-PB3-PCU
PROFIBUS PCI interface card
TBDPB-4xxx-B8U
IP67 PROFIBUS I/O compact block 4 ports, 8 channels
PA9D01-42
PA9S01-42
PROFIBUS connector with integrated diagnostics, vertical
PROFIBUS connector, vertical
MA9D00-42
PROFIBUS connector with integrated diagnostics,
horizontal
PBSTRIP
Cable stripping tool for use with PROFIBUS connector
85-001
PROFIBUS cable
To contact us: www.woodhead.com
Reference Number: DW2006135
Date Published: April 2006
North America: US + 1 800 225 7724 -Canada, +1 519 725 5136
Europe:
France, +33 2 32 96 04 20 – Germany, +49 711 782 3740 – Italy, +39 010 59 30 77 –
United Kingdom, +44 1495 356300
Asia:
China, +86 21 50328080 – Singapore, +65 261 6533 – Japan, +81 45 224 3560
Brad Harrison is a registered trademark and BradConnectivity, BradCommunications and SST are trademarks of
Woodhead Industries, Inc. © 2006 Woodhead Industries, Inc.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement