Friedrich Submittal

Add to my manuals
2 Pages

advertisement

Friedrich Submittal | Manualzz

PURCHASER

PROJECT

ENGINEER

SUBMITTED BY

ITEM PLAN DESIGNATION QUANTITY

Wallmaster

®

Thru-the-wall

Air Conditioners, Heat Pumps & Electric Heat models

DATE P.O. #

LOCATION

ARCHITECT

FOR APPROVAL FOR REFERENCE

COOLING BTU/H VOLTAGE FRIEDRICH MODEL

Comfort & Convenience

• Easy-to-reach, top mount controls

• Remote control

• 24 hour programmable timer

• Smart Fan auto-adjusts fan speed to maintain desired temperature

• 3 speed fan

• Washable, antimicrobial filter

• Auto restart

• Electronic defrost control

• Insect barrier

• Reversible louver allows a second airflow option

Energy Savings

• Money Saver® setting saves money by operating the fan only when needed

• Six Energy Star models

Durability & Quality

• Rotary compressors provide quiet, dependable performance

• Premium stamped exterior grille

• Dense blower insulation

• Rifled copper tubing

• Impact resistant front cover

• High tech fins with sine wave lanced louvers increase energy efficiency by increasing surface area for heat exchange

Installation Features

• Mounts flush with the exterior wall for a neat appearance

• Ideal for thicker wall installations, where side fins don’t fit

• A high efficiency replacement for 27” sleeves including Fedders A and B*.

Sleeve measures 27” W x 16 3/4” H

Accessories

• WSD sleeve (sleeve is required for new installation and is sold and shipped separately)

• Architectural grille

• Drain kit

• Interior drain kit

• Subbase

• Baffle adapter kit

Sleeve Dimensions

Height (inches)

Width (inches)

Depth (inches)

Friedrich

WSD Sleeve

16 3/4

27

16 3/4

Fedders

A Sleeve

16 3/4

27

16 3/4

Fedders

B Sleeve*

16 3/4

27

19 3/4

Thru-the-wall_WallMaster_Submittal_2013

Specifications

Model Cooling Btu

WALLMASTER ®

Cool only

 WS08C10

 WS10C10

 WS12C10C

7800

9700

11500

 WS10C30

 WS12C30

9500/9200

11500/11200

WS16C30

Heat Pump

 WY09C33

15600/15000

9300/9000

WY12C33 12000/11800

Cool with Electric Heat

WE10C33 9500/9200

WE12C33 11500/11200

WE16C33 15600/15000

Heating Btu

NA

NA

NA

NA

NA

NA

7300/7300

9350/9200

11000/9100

11000/9100

11000/9100

Volts

Rated

Cooling

Amps

Cooling

Watts

115

115

7.1

10.0

115 11.5

230/208 4.5/4.7

230/208 5.5/6.0

230/208 8.3/8.9

788

1032

1223

989/958

1223/1191

1835/1765

230/208 4.4/4.7

230/208 6.1/6.4

989/957

1395/1372

Heating

Amps

NA

NA

NA

NA

NA

NA

3.8/4.0

4.8/5.1

Heating

Watts

NA

NA

NA

NA

NA

NA

839/793

1062/1010

230/208 4.5/4.7

230/208 5.5/6.0

230/208 8.3/8.9

989/957 16.0/14.7

1123/1191 16.0/14.7

1835/1765 16.0/14.7

3550/2950

3550/2950

3550/2950

 E nErgy

S tar

® qualified

Energy

Efficiency

Ratio

EER

Estimated

Yearly

Operating

Cost

Moisture

Removal

Pints/HR CFM Sleeve

Net

Weight

Lbs.

Ship

Weight

Lbs

9.9

9.4

9.4

9.6/9.6

9.4/9.4

8.5/8.5

9.4/9.4

8.6/8.6

9.6/9.6

9.4/9.4

8.5/8.5

$82

$98

$79

$98

$144

$79

$111

$79

$98

$140

1.2

2.4

3.1

1.5

3.0

4.2

2.1

2.6

1.5

3.0

4.2

250

260

320

300

320

290

250

275

300

320

290

WSD

WSD

WSD

WSD

WSD

WSD

WSD

WSD

WSD

WSD

WSD

93

103

112

101

109

119

103

111

121

107

116

97

107

116

105

113

123

107

115

125

111

120

WallMaster Heat Pump heating information indicates heat pump heating performance. WallMaster Electric Heat heating information indicates electric heat strip performance. For WallMaster Heat Pump electric heating performance refer to corresponding WallMaster Electric Heat model.

WALLMASTER HEAT PUMP

HEATING PERFORMANCE: Change-over from heat pump operation to resistance operation on models indicated is automatic at a preset outside ambient temperature of approximately 35°F.

Calculate the heat loss of the space to be heated. As long as the heat loss does not exceed the resistance heating capacity rating of the unit, the heating performance will be satisfactory.

Note: all models will produce condensate. If condensate disposal is desired, an optional drain kit is available.

DEFROST CONTROL: Initiated at 30°F (outdoor coil temperature) and terminated at 43°F (outdoor coil temperature). During defrost, the compressor stops and the electric heat starts, then operates with the fan to maintain indoor comfort. Below

43°F, the unit remains in electric heat mode.

During electric heat mode, the unit will achieve the following ratings: 11000/9100

BTU/h, 16.0/14.7 amps, and 3550/2950 watts.

DEFROST DRAIN: Drain automatically opens at approximately 50°F to prevent condensate from freezing inside drain pan.

Plug Face/ Circuit Rating

WallMaster

Model Number

WS08C10, WS10C10,

WS12C10

WS10C30, WS13C30,

WS16C30

WE10C33, WE13C33,

WE16C33, WY09C33, WY12C33

Circuit Rating

Breaker

or T-D Fuse

125V - 15A

250V - 15A

250V - 20A

Power cords are located on front left of WallMaster models.

Plug Face

(NEMA#)

5 - 15P

6 - 15P

6 - 20P

Sleeve/Chassis Dimensions

Power Cord

Length (ft.)

Wall

Outlet

Appearance

6

4

4

Model

WallMaster

WSD Sleeve 16 3/4" 27" 16 3/4"

Chassis

Height Width

15 3/4" 26 1/2"

Depth

21"

Depth with

Front

23"

22”

Minimum

Extension

Into Room

7 1/2"

Minimum

Extension

Outside

Thru-the-wall

Finished Hole

Height Width Max. Depth

9/16"

17 1/4" 27 1/4"

– –

15 5/16"

Chassis requires WSD sleeve (sold and shipped separately)

*Installation in Fedders B sleeve requires a baffle kit. See BAK accessory under accessories.

Model

WallMaster ®

WSD Sleeve

Chassis

Uni-Fit ®

USC Sleeve

US Chassis

UE Chassis

Carton Dimensions

INCHES

Height Width Depth

18" 27 1/4" 18"

18 1/2" 30 1/2" 29"

17 7/8" 28" 19 1/4"

17 1/4" 27 3/4" 22 1/4”

17 1/4" 27 3/4” 22 1/4”

LISTED

ROOM AIR CONDITIONERS

183H

As an E nErgy

S tar

E nErgy

S tar

®

® partner, Friedrich Air Conditioning Co. has determined that the selected

models meet the E nErgy

S tar

® guidelines for energy efficiency.

Thru-the-wall_WallMaster_Submittal_2013

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement