Product Data Sheet: Damcos DPHS, PHS and P3

Product Data Sheet: Damcos DPHS, PHS and P3
Product Data Sheet
February 2015
SD 3100-0E05
Damcos DPHS, PHS and P3
™
Accessories for valve/actuator area
TM
43
PHS-Block G1/4"
Damcos DPHS,
PHS and P3
5
6
February 2015
33
Description
12
18
69
The following accessories for valve and actuator area are available for typical applications as described below.
14,5
Unit
Typical Application
Block with single quick connection and
stop valve. The block has connection
tread G3/8” or G1/4”.
For emergency operation of 1-line actuators
(spring return) by means of portable hand
pump. The block is pipe mounted.
Plate for cross - connecting ports P and
A, respectively B and T of a Cetop-3/NG
6 stack.
Whenever a Cetop-3/NG 6 mounting block
is used for mounting of control equipment
on the actuator, a P3 plate is necessary to
close the Cetop-3 “sandwich”.
Bleed pipe from actuator can be connected to block.
For emergency operation of 1-line submerged actuator (fail close) by means of
portable hand pump. The block is pipe
mounted.
PHS Bleeder Fail Open, submerged
Bleed pipe from actuator can be connected to block.
For emergency operation of 1-line submerged actuator (fail open) by means of
portable hand pump. The block is pipe
mounted.
DPHS Pipe Block, submerged
For emergency operation of 2-line
actuator by means of portable hand
pump. The block is pipe mounted.
For emergency operation of 2-line actuator
or system consisting LPU, both S and D, by
means of portable hand pump.
DPHS Flushing Block for Manifold
Used for shutting off connection to
manifold when flushing or connecting
and operating acturators by portable
hand pump from outside the deck-box.
The block has connection tread G3/8”
(G1/4” in manifolds).
Two versions one for brass manifold and
one for acid proof manifold.
Installation requirements: Damcos Brass
manifold or acid proof manifold 75 mm
pitch only.
For use of shutting off connection to manifold when flushing, connecting and operating actuators by portable hand pump from
outside the deck-box.
11
30
49
S-Block with bleeder, Fail Close
Description
20
PHS Pipe Block
13
24
30
38
G1/4”
G3/8”
14
40
14
71,5
P3 Cross-Over Plate
bleeder fail open
60
11
38
49
30
71,5
40
16
14
11
38
PHS Bleeder Fail Close, submerged
40
60
16
27
49
40
S-Block
71,5
60
40
14
30
60
16
38
49
40
2
11
Damcos DPHS, PHS and P3
February 2015
Technical Specification
PHS
Maximum operation pressure
Maximum test pressure
Flow rate at 100 bar (50 cSt
visc.) l/min
Temperature range
Weight approx. kg/lb
Seals
Housing
Screws
Quick connection
P3
PHS - bleed
fail close
PHS - bleed
fail open
135 bar/2000 PSI
225 bar/3250 PSI
6
DPHS
pipe block
DPHS*
flushing block
Brass / SS
6
7/5
1.1 / 2.4
1.6 / 3.5
MS 58 / AISI
316L
A4-80
MS 58 / AISI
316L
6
20
6
0.6 / 1.3
NBR
MS 58 or
AISI 316L
None
MS 58 or
AISI 316L
0.2 / 0.4
1.1 / 2.4
MS 58
MS 58
MS 58
MS 58
None
MS 58
None
MS 58
None
MS 58
None
MS 58
-20°C to +80°C
1.1 / 2.4
*) Versions made for 60 bar is good for burst pressure 445 bar!
Hydraulic diagram
PHS Block
3
Damcos DPHS, PHS and P3
Hydraulic diagram
PHS block with bleeder for fail close
PHS block with bleeder for fail open
4
February 2015
February 2015
Damcos DPHS, PHS and P3
DPHS Flushing Block for Manifold
5
Damcos DPHS, PHS and P3
February 2015
Main dimensions
PHS
PHS Pipe Block G3/8”
PHS Bleeder Fail Open
PHS Pipe Block G1/4”
PHS Bleeder Fail Close
M8 x 12/16
6
Damcos DPHS, PHS and P3
February 2015
P3
DPHS Pipe Block
DPHS Mounting on Manifold
7
Damcos DPHS, PHS and P3
Product Data Sheet
SD 3100-0E05
February 2015
©2014 Emerson Process Management. All rights reserved.
Emerson Process Management
Damcos A/S
Aaderupvej 41
DK-4700 Naestved
T +45 5578 7200
F +45 5578 7272
www.EmersonProcess.com/mtm
TM
The Emerson logo is a trademark and service mark of Emerson Electric Co. Damcos® and the
Damcos logotype are registered trademarks of Damcos A/S.
The contents of this publication are presented for information purposes only, and while effort has
been made to ensure their accuracy, they are not to be construed as warranties or guarantees,
expressed or implied, regarding the products or services described herein or their use or
applicability. Standard Terms and Conditions of Sale can be issued by contacting Damcos A/S. We
reserve the right to modify or improve the designs and specifications of our products at any time
without notice.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement