SIM900R_Safety_Test Report

SIM900R_Safety_Test Report
Test Report issued under the responsibility of:
TEST REPORT
IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006
Information technology equipment – Safety –
Part 1: General requirements
Report Reference No. ....................:
SH11070685-001
Date of issue ....................................:
2011-7-8
Total number of pages ......................
45 pages
CB/CCA Testing Laboratory..........:
Intertek Testing Services Shanghai Limited
Address ............................................:
Building No.86, 1198 Qinzhou Road (North), Shanghai 200233,
China
Applicant’s name............................:
Shanghai Simcom Ltd.
Address ............................................:
Build A, No. 633 JinZhong Rd., ChangNing District Shanghai, PRC
China
Manufacturer’s name .....................:
Shanghai Simcom Ltd.
Address ............................................:
Build A, No. 633 JinZhong Rd., ChangNing District Shanghai, PRC
China
Factory’s name ...............................:
Shanghai Simcom Ltd.
Address ............................................:
Build A, No. 633 JinZhong Rd., ChangNing District Shanghai, PRC
China
Test specification:
Standard...........................................:
IEC 60950-1:2005 (2nd Edition) + A1:2009 and/or
EN 60950-1:2006 + A11:2009 + A1:2010
Test procedure .................................:
CE
Non-standard test method…………..:
N/A
Test Report Form No. ....................:
IECEN60950_1C
Test Report Form(s) Originator ........:
SGS Fimko Ltd
Master TRF ......................................:
Dated 2007-06
Copyright © 2007 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme
procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended
to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
If this Test Report Form is used by non-CCA members, the CIG logo and the reference to the CCA Procedure shall be
removed.
This report is not valid as a CCA Test Report unless signed by an approved CCA Testing Laboratory and
appended to a CCA Test Certificate issued by an NCB in accordance with CCA
Page 2 of 45
Test item description .....................:
GSM/GPRS Module
Trade Mark ....................................... :
SIMCom
Manufacturer .................................... :
Shanghai Simcom Ltd.
Model/Type reference ...................... :
SIM900R
Ratings ............................................. :
(3.4-4.5)Vd.c.
Report No.SH11070685-001
Page 3 of 45
Report No.SH11070685-001
Testing procedure and testing location:
CB/CCA Testing Laboratory:
Testing location/ address ...................... :
Intertek Testing Services Shanghai Limited
Building No.86, 1198 Qinzhou Road (North), Shanghai
200233, China
Associated CB Laboratory:
Testing location/ address ...................... :
Tested by (name + signature) ..... :
Valiant Sun
Approved by (+ signature)........... :
Justin Yu
Testing procedure: TMP
Tested by (name + signature) ..... :
Approved by (+ signature)............ :
Testing location/ address ...................... :
Testing procedure: WMT
Tested by (name + signature) ..... :
Witnessed by (+ signature) .......... :
Approved by (+ signature)........... :
Testing location/ address ...................... :
Testing procedure: SMT
Tested by (name + signature) ..... :
Approved by (+ signature)............ :
Supervised by (+ signature) ........ :
Testing location/ address ................:
Testing procedure: RMT
Tested by (name + signature) ..... :
Approved by (+ signature)............ :
Supervised by (+ signature) ........ :
Testing location/ address ...................... :
TRF No. IECEN60950_1C
Page 4 of 45
Report No.SH11070685-001
Summary of testing:
Tests performed (name of test and test clause):
Testing location:
The sample tested complies with the requirements of IEC
60950-1:2005 and EN 60950-1:2006+A11:2009+A1:2010
Intertek Testing Services Shanghai Limited
Summary of compliance with National Differences:
Copy of marking plate
SIM900R marking plate:
TRF No. IECEN60950_1C
Building No.86, 1198 Qinzhou Road (North),
Shanghai 200233, China
Page 5 of 45
Report No.SH11070685-001
Test item particulars .................................................. :
Equipment mobility .................................................... : [] movable [] hand-held
[] transportable
[] stationary [x] for building-in [] direct plug-in
Connection to the mains ........................................... : [] pluggable equipment [] type A [] type B
[] permanent connection
[] detachable power supply cord
[] non-detachable power supply cord
[x] not directly connected to the mains
Operating condition ................................................... : [x] continuous
[] rated operating / resting time:
Access location ........................................................ : [x] operator accessible
[] restricted access location
Over voltage category (OVC) ................................... : [x] OVC I
[] other:
[] OVC II
[] OVC III
[] OVC IV
Mains supply tolerance (%) or absolute mains supply N/A
values ....................................................................... :
Tested for IT power systems .................................... : [] Yes
[x] No
IT testing, phase-phase voltage (V) ......................... : N/A
Class of equipment ................................................... : [] Class I [] Class II
[] Not classified
[x] Class III
Considered current rating (A) ................................... :
Pollution degree (PD) ............................................... : [] PD 1
[x] PD 2
[] PD 3
IP protection class .................................................... : IPX0
Altitude during operation (m) .................................... : Max. 5000m
Altitude of test laboratory (m) ................................... : Max. 50m
Mass of equipment (kg) ............................................ : Approx. 3.4g
Possible test case verdicts:
- test case does not apply to the test object .................: N/A
- test object does meet the requirement.......................: P (Pass)
- test object does not meet the requirement.................: F (Fail)
Testing ..........................................................................:
Date of receipt of test item ............................................: 2011-6-27
Date(s) of performance of tests ....................................: 2011-6-27 ~ 2011-7-8
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.
"(See Enclosure #)" refers to additional information appended to the report.
"(See appended table)" refers to a table appended to the report.
Note: This TRF includes EN Group Differences together with National Differences and Special
National Conditions, if any. All Differences are located in the Appendix to the main body of this TRF.
Throughout this report a comma (point) is used as the decimal separator.
TRF No. IECEN60950_1C
Page 6 of 45
Report No.SH11070685-001
General product information:
The equipment submitted for tests is a GSM/GPRS module (Type ) which is mounted on a circuit board.
TRF No. IECEN60950_1C
Page 7 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
1
GENERAL
1.5
Components
1.5.1
General
Components which were
found to affect safety aspects
comply with the requirements
of this standard or within the
safety aspects of the relevant
IEC/EN component
standards.
Pass
Comply with IEC 60950-1 or relevant component
standard
(see appended table 1.5.1)
Pass
1.5.2
Evaluation and testing of components
Components which are
certified to IEC and/or
national standards are used
correctly within their ratings.
Components not covered by
IEC standards are tested
under the conditions present
in the equipment.
Pass
1.5.3
Thermal controls
No thermal controls.
N/A
1.5.4
Transformers
See Annex C-Transformers.
N/A
1.5.5
Interconnecting cables
No such device within the EUT
N/A
1.5.6
Capacitors bridging insulation
No such component used.
N/A
1.5.7
Resistors bridging insulation
No such component used.
N/A
1.5.7.1
Resistors bridging functional, basic or
supplementary insulation
N/A
1.5.7.2
Resistors bridging double or reinforced insulation
between a.c. mains and other circuits
N/A
1.5.7.3
Resistors bridging double or reinforced insulation
between a.c. mains and antenna or coaxial cable
N/A
1.5.8
Components in equipment for IT power systems
1.5.9
Surge suppressors
1.5.9.1
General
1.5.9.2
Protection of VDRs
N/A
N/A
1.5.9.3
Bridging of functional insulation by a VDR
N/A
1.5.9.4
Bridging of basic insulation by a VDR
N/A
1.5.9.5
Bridging of supplementary, double or reinforced
insulation by a VDR
N/A
TRF No. IECEN60950_1C
Result - Remark
Verdict
Pass
Not used for IT power
systems.
No surge suppressors used
N/A
N/A
Page 8 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
1.6
Power interface
1.6.1
AC power distribution systems
No primary circuit existed.
N/A
1.6.2
Input current
N/A
1.6.3
Voltage limit of hand-held equipment
No connection to mains
Class III equipment.
1.6.4
Neutral conductor
No primary circuit existed.
N/A
1.7
Marking and instructions
1.7.1
Power rating
N/A
N/A
Pass
See below.
N/A
Rated voltage(s) or voltage range(s) (V) .............. :
N/A
Symbol for nature of supply, for d.c. only .............. :
N/A
Rated frequency or rated frequency range (Hz) ... :
DC input.
N/A
Rated current (mA or A) ........................................ :
N/A
Manufacturer’s name or trade-mark or identification Shanghai Simcom Ltd.
mark ...................................................................... :
Pass
Model identification or type reference ................... :
SIM900R
Pass
Symbol for Class II equipment only ...................... :
Class Ⅲ
N/A
Other markings and symbols ................................ :
No other markings and
symbols
The specification provided
that contains all necessary
safety information such as the
maximum ambient
temperature etc.
N/A
1.7.2
Safety instructions and marking
Pass
1.7.2.1
General
1.7.2.2
Disconnect devices
1.7.2.3
Overcurrent protective device
N/A
1.7.2.4
IT power distribution systems
N/A
1.7.2.5
Operator access with a tool
1.2.7.6
Ozone
1.7.3
Short duty cycles
Continuous operation.
N/A
1.7.4
Supply voltage adjustment ................................... :
No voltage/frequency setting.
N/A
N/A
No disconnect devices
No need.
N/A
N/A
N/A
Methods and means of adjustment; reference to
installation instructions ......................................... :
N/A
1.7.5
Power outlets on the equipment .......................... :
No standard power outlets.
N/A
1.7.6
Fuse identification (marking, special fusing
characteristics, cross-reference) .......................... :
No fuse used.
N/A
1.7.7
Wiring terminals
No wiring terminals used.
N/A
1.7.7.1
Protective earthing and bonding terminals .......... :
Class III equipment.
N/A
TRF No. IECEN60950_1C
Page 9 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
1.7.7.2
Terminals for a.c. mains supply conductors
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
N/A
1.7.8
Controls and indicators
1.7.8.1
Identification, location and marking ..................... :
N/A
1.7.8.2
Colours ................................................................ :
N/A
1.7.8.3
Symbols according to IEC 60417 ........................ :
N/A
1.7.8.4
Markings using figures ....................................... :
N/A
1.7.9
Isolation of multiple power sources ..................... :
N/A
1.7.10
Thermostats and other regulating devices .......... :
No such devices.
N/A
1.7.11
Durability
The label was subjected to
the permanence of marking
test.
N/A
No safety relevant control or
indicator used.
Verdict
N/A
The label was rubbed with
cloth soaked with water for
15s and then again for 15s
with the cloth soaked with
petroleum spirit.
After this test, there was no
damage to the label. The
marking on the label did not
fade. There was no curling
nor lifting of the label edge.
1.7.12
Removable parts
1.7.13
Replaceable batteries ......................................... :
1.7.14
No removable parts
N/A
Language(s) ........................................................ :
English
Equipment for restricted access locations ........... :
Not intended for use in
restricted access locations.
TRF No. IECEN60950_1C
N/A
⎯
N/A
Page 10 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
2
PROTECTION FROM HAZARDS
Pass
2.1
Protection from electric shock and energy hazards
N/A
2.1.1
Protection in operator access areas
2.1.1.1
Access to energized parts
N/A
Test by inspection ................................................. :
N/A
Test with test finger (Figure 2A) ............................ :
N/A
Test with test pin (Figure 2B) ................................ :
N/A
Test with test probe (Figure 2C) ........................... :
N/A
Class III equipment.
Verdict
N/A
2.1.1.2
Battery compartments
No TNV circuits provided
N/A
2.1.1.3
Access to ELV wiring
Class III equipment.
N/A
⎯
Working voltage (Vpeak or Vrms); minimum
distance through insulation (mm)
2.1.1.4
Access to hazardous voltage circuit wiring
Class III equipment.
N/A
2.1.1.5
Energy hazards ..................................................... :
Class III equipment.
N/A
2.1.1.6
Manual controls
No conductive handles,
knobs.
N/A
2.1.1.7
Discharge of capacitors in equipment
Class III equipment.
N/A
Measured voltage (V); time-constant (s)................ :
(see appended table 2.1.1.7)
Energy hazards – d.c. mains supply
No energy hazards existed
2.1.1.8
⎯
N/A
a) Capacitor connected to the d.c. mains supply .. :
N/A
b) Internal battery connected to the d.c. mains
supply .................................................................... :
N/A
2.1.1.9
Audio amplifiers ..................................................... :
No Audio amplifiers used.
N/A
2.1.2
Protection in service access areas
No energy hazards existed
N/A
2.1.3
Protection in restricted access locations
The unit is not intended to be
used in restricted locations.
N/A
2.2
SELV circuits
2.2.1
General requirements
SELV circuit does not exceed
42.4 V peak or 60 V dc under
normal operation or single
fault condition.
Pass
2.2.2
Voltages under normal conditions (V) ................... :
Between any SELV circuits
42.4V peak or 60VDC are not
exceeded. (see appended
table)
Pass
TRF No. IECEN60950_1C
Pass
Page 11 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
2.2.3
Voltages under fault conditions (V) ....................... :
2.2.4
Connection of SELV circuits to other circuits ...... :
Limits of 71V peak and 120V
DC were not exceed and
SELV limits not for longer
than 0.2 seconds. (see
appended table)
No direct connection between
SELV and any primary
circuits.
2.3
TNV circuits
2.3.1
Limits
Verdict
Pass
Pass
N/A
No TNV circuits.
N/A
Type of TNV circuits............................................... :
⎯
2.3.2
Separation from other circuits and from accessible
parts
N/A
2.3.2.1
General requirements
N/A
2.3.2.2
Protection by basic insulation
N/A
2.3.2.3
Protection by earthing
N/A
2.3.2.4
Protection by other constructions ......................... :
N/A
2.3.3
Separation from hazardous voltages
N/A
⎯
Insulation employed ............................................... :
2.3.4
Connection of TNV circuits to other circuits
N/A
⎯
Insulation employed ............................................... :
2.3.5
Test for operating voltages generated externally
N/A
2.4
Limited current circuits
N/A
2.4.1
General requirements
2.4.2
Limit values
No such limited current
circuits.
(See appended table 2.4.2)
N/A
Frequency (Hz) ...................................................... :
(See appended table 2.4.2)
⎯
Measured current (mA) .......................................... :
(See appended table 2.4.2)
⎯
Measured voltage (V)............................................. :
(See appended table 2.4.2)
⎯
Measured circuit capacitance (nF or µF) ............... :
N/A
⎯
2.4.3
Connection of limited current circuits to other
circuits
N/A
2.5
Limited power sources
N/A
a) Inherently limited output
N/A
b) Impedance limited output
N/A
TRF No. IECEN60950_1C
Page 12 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
c) Regulating network limited output under normal
operating and single fault condition
(See appended table 2.5)
d) Overcurrent protective device limited output
Max. output voltage (V), max. output current (A),
max. apparent power (VA) ..................................... :
Verdict
N/A
N/A
(See appended table 2.5)
⎯
⎯
Current rating of overcurrent protective device (A) .:
2.6
Provisions for earthing and bonding
N/A
2.6.1
Protective earthing
2.6.2
Functional earthing
N/A
2.6.3
Protective earthing and protective bonding
conductors
N/A
2.6.3.1
General
N/A
2.6.3.2
Size of protective earthing conductors
Class III equipment.
N/A
2
⎯
Rated current (A), cross-sectional area (mm ),
AWG....................................................................... :
2.6.3.3
N/A
Size of protective bonding conductors
N/A
2
⎯
Rated current (A), cross-sectional area (mm ),
AWG....................................................................... :
Protective current rating (A), cross-sectional area
(mm2), AWG........................................................... :
(see appended table 2.6.3.4)
2.6.3.4
Resistance of earthing conductors and their
terminations; resistance (Ω), voltage drop (V), test
current (A), duration (min)...................................... :
2.6.3.5
Colour of insulation ................................................ :
N/A
2.6.4
Terminals
N/A
2.6.4.1
General
N/A
2.6.4.2
Protective earthing and bonding terminals
N/A
Rated current (A), type, nominal thread diameter
(mm)....................................................................... :
N/A
⎯
2.6.4.3
Separation of the protective earthing conductor
from protective bonding conductors
N/A
2.6.5
Integrity of protective earthing
N/A
2.6.5.1
Interconnection of equipment
N/A
2.6.5.2
Components in protective earthing conductors and
protective bonding conductors
N/A
2.6.5.3
Disconnection of protective earth
N/A
2.6.5.4
Parts that can be removed by an operator
N/A
2.6.5.5
Parts removed during servicing
N/A
TRF No. IECEN60950_1C
Page 13 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
2.6.5.6
Corrosion resistance
N/A
2.6.5.7
Screws for protective bonding
N/A
2.6.5.8
Reliance on telecommunication network or cable
distribution system
N/A
2.7
Overcurrent and earth fault protection in primary circuits
N/A
2.7.1
Basic requirements
N/A
Class III equipment.
Verdict
Instructions when protection relies on building
installation
N/A
2.7.2
Faults not simulated in 5.3.7
N/A
2.7.3
Short-circuit backup protection
N/A
2.7.4
Number and location of protective devices ........... :
N/A
2.7.5
Protection by several devices
N/A
2.7.6
Warning to service personnel ................................ :
N/A
2.8
Safety interlocks
N/A
2.8.1
General principles
2.8.2
Protection requirements
N/A
2.8.3
Inadvertent reactivation
N/A
2.8.4
Fail-safe operation
N/A
2.8.5
Moving parts
N/A
2.8.6
Overriding
N/A
2.8.7
Switches and relays
N/A
2.8.7.1
Contact gaps (mm) ................................................ :
N/A
2.8.7.2
Overload test
N/A
2.8.7.3
Endurance test
N/A
2.8.7.4
Electric strength test
N/A
2.8.8
Mechanical actuators
N/A
2.9
Electrical insulation
Pass
2.9.1
Properties of insulating materials
2.9.2
Humidity conditioning
No safety interlock.
Natural rubber, asbestos or
hygroscopic materials are not
used.
Grade of insulation
2.9.4
Separation from hazardous voltages
TRF No. IECEN60950_1C
Pass
N/A
⎯
Relative humidity (%), temperature (°C) ............... :
2.9.3
N/A
Function insulation
N/A
N/A
Page 14 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
⎯
Method(s) used ..................................................... :
2.10
Clearances, creepage distances and distances through insulation
N/A
2.10.1
General
See 2.10.3, 2.10.4 and
2.10.5.
N/A
2.10.1.1
Frequency ............................................................. :
Class III equipment.
N/A
2.10.1.2
Pollution degrees .................................................. :
N/A
2.10.1.3
Reduced values for functional insualtion
N/A
2.10.1.4
Intervening unconnected conductive parts
N/A
2.10.1.5
Insulation with varying dimensions
N/A
2.10.1.6
Special separation requirements
N/A
2.10.1.7
Insulation in circuits generating starting pulses
N/A
2.10.2
Determination of working voltage
2.10.2.1
General
N/A
2.10.2.2
RMS working voltage
N/A
2.10.2.3
Peak working voltage
N/A
2.10.3
Clearances
2.10.3.1
General
N/A
2.10.3.2
Mains transient voltages
N/A
a) AC mains supply ............................................... :
Class III equipment.
See below.
Not connected to a AC mains
supply.
N/A
N/A
N/A
b) Earthed d.c. mains supplies .............................. :
N/A
c) Unearthed d.c. mains supplies .......................... :
N/A
d) Battery operation ............................................... :
N/A
2.10.3.3
Clearances in primary circuits
(see appended table 2.10.3
and 2.10.4)
N/A
2.10.3.4
Clearances in secondary circuits
(see appended table 2.10.3
and 2.10.4)
N/A
2.10.3.5
Clearances in circuits having starting pulses
(see appended table 2.10.3
and 2.10.4)
N/A
2.10.3.6
Transients from a.c. mains supply ........................ :
N/A
2.10.3.7
Transients from d.c. mains supply ........................ :
N/A
2.10.3.8
Transients from telecommunication networks and
cable distribution systems ..................................... :
N/A
2.10.3.9
Measurement of transient voltage levels
N/A
a) Transients from a mains suplply
N/A
For an a.c. mains supply ....................................... :
N/A
TRF No. IECEN60950_1C
Page 15 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
For a d.c. mains supply ......................................... :
N/A
b) Transients from a telecommunication network :
N/A
2.10.4
Creepage distances
N/A
2.10.4.1
General
N/A
2.10.4.2
Material group and caomparative tracking index
N/A
⎯
CTI tests ................................................................. :
2.10.4.3
Minimum creepage distances
2.10.5
Solid insulation
N/A
2.10.5.1
General
N/A
2.10.5.2
Distances through insulation
2.10.5.3
Insulating compound as solid insulation
N/A
2.10.5.4
Semiconductor devices
N/A
2.10.5.5.
Cemented joints
N/A
2.10.5.6
Thin sheet material – General
N/A
2.10.5.7
Separable thin sheet material
N/A
Number of layers (pcs)........................................... :
(see appended table 2.10.3
and 2.10.4)
(see appended table 2.10.5)
See annex C
N/A
N/A
⎯
2.10.5.8
Non-separable thin sheet material
N/A
2.10.5.9
Thin sheet material – standard test procedure
N/A
⎯
Electric strength test
2.10.5.10
Thin sheet material – alternative test procedure
N/A
⎯
Electric strength test
2.10.5.11
Insulation in wound components
2.10.5.12
Wire in wound components
N/A
Working voltage .................................................... :
N/A
a) Basic insulation not under stress ...................... :
N/A
b) Basic, supplemetary, reinforced insulation ....... :
N/A
c) Compliance with Annex U ................................. :
N/A
Two wires in contact inside wound component;
angle between 45° and 90° ................................... :
N/A
Wire with solvent-based enamel in wound
components
N/A
2.10.5.13
Electric strength test
2.10.5.14
No wound components.
(see appended table 2.10.5)
N/A
⎯
Routine test
N/A
Additional insulation in wound components
N/A
Working voltage .................................................... :
N/A
TRF No. IECEN60950_1C
Page 16 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
- Basic insulation not under stress ........................ :
N/A
- Supplemetary, reinforced insulation ................... :
N/A
2.10.6
Construction of printed boards
N/A
2.10.6.1
Uncoated printed boards
(see appended table 2.10.3
and 2.10.4)
N/A
2.10.6.2
Coated printed boards
No coated printed board
used.
N/A
2.10.6.3
Insulation between conductors on the same inner
surface of a printed board
Not multi-layer printed board.
N/A
2.10.6.4
Insulation between conductors on different layers of No such printed board use.
a printed board
N/A
Distance through insulation
N/A
Number of insulation layers (pcs) .......................... :
N/A
2.10.7
Component external terminations
N/A
2.10.8
Tests on coated printed boards and coated
components
2.10.8.1
Sample preparation and preliminary inspection
N/A
2.10.8.2
Thermal conditioning
N/A
2.10.8.3
Electric strength test
2.10.8.4
Abrasion resistance test
N/A
2.10.9
Thermal cycling
N/A
2.10.10
Test for Pollution Degree 1 environment and
insulating compound
N/A
2.10.11
Tests for semiconductor devices and cemented
joints
N/A
2.10.12
Enclosed and sealed parts
N/A
TRF No. IECEN60950_1C
No coated printed boards and
coated components.
(see appended table 5.2)
N/A
N/A
Page 17 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
3
WIRING, CONNECTIONS AND SUPPLY
Pass
3.1
General
N/A
3.1.1
Current rating and overcurrent protection
3.1.2
Protection against mechanical damage
N/A
3.1.3
Securing of internal wiring
N/A
3.1.4
Insulation of conductors
3.1.5
Beads and ceramic insulators
N/A
3.1.6
Screws for electrical contact pressure
N/A
3.1.7
Insulating materials in electrical connections
N/A
3.1.8
Self-tapping and spaced thread screws
N/A
3.1.9
Termination of conductors
N/A
10 N pull test
N/A
3.1.10
Sleeving on wiring
N/A
3.2
Connection to a mains supply
N/A
3.2.1
Means of connection
3.2.1.1
Connection to an a.c. mains supply
N/A
3.2.1.2
Connection to a d.c. mains supply
N/A
3.2.2
Multiple supply connections
N/A
3.2.3
Permanently connected equipment
N/A
No primary circuits exist.
(see appended table 5.2)
Class III equipment.
Verdict
N/A
N/A
N/A
⎯
Number of conductors, diameter of cable and
conduits (mm) ....................................................... :
3.2.4
Appliance inlets
N/A
3.2.5
Power supply cords
N/A
3.2.5.1
AC power supply cords
Type ...................................................................... :
2
Rated current (A), cross-sectional area (mm ),
AWG ..................................................................... :
(see appended table 1.5.1)
N/A
(see appended table 1.5.1)
⎯
(see appended table 1.5.1)
⎯
3.2.5.2
DC power supply cords
N/A
3.2.6
Cord anchorages and strain relief
N/A
Mass of equipment (kg), pull (N) ......................... :
⎯
Longitudinal displacement (mm) ........................... :
⎯
3.2.7
Protection against mechanical damage
N/A
3.2.8
Cord guards
N/A
TRF No. IECEN60950_1C
Page 18 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
Diameter or minor dimension D (mm); test mass (g)
............................................................................... :
⎯
Radius of curvature of cord (mm) .......................... :
⎯
3.2.9
Supply wiring space
N/A
3.3
Wiring terminals for connection of external conductors
N/A
3.3.1
Wiring terminals
N/A
3.3.2
Connection of non-detachable power supply cords
N/A
3.3.3
Screw terminals
N/A
3.3.4
Conductor sizes to be connected
N/A
No wiring terminals used.
⎯
Rated current (A), cord/cable type, cross-sectional
area (mm2) ............................................................. :
3.3.5
Wiring terminal sizes
N/A
⎯
Rated current (A), type, nominal thread diameter
(mm) ...................................................................... :
3.3.6
Wiring terminal design
N/A
3.3.7
Grouping of wiring terminals
N/A
3.3.8
Stranded wire
N/A
3.4
Disconnection from the mains supply
N/A
3.4.1
General requirement
N/A
3.4.2
Disconnect devices
N/A
3.4.3
Permanently connected equipment
N/A
3.4.4
Parts which remain energized
N/A
3.4.5
Switches in flexible cords
N/A
3.4.6
Number of poles - single-phase and d.c. equipment
N/A
3.4.7
Number of poles - three-phase equipment
N/A
3.4.8
Switches as disconnect devices
N/A
3.4.9
Plugs as disconnect devices
N/A
3.4.10
Interconnected equipment
N/A
3.4.11
Multiple power sources
N/A
3.5
Interconnection of equipment
Pass
3.5.1
General requirements
Pass
3.5.2
Types of interconnection circuits .......................... :
Interconnection for SELV.
Pass
3.5.3
ELV circuits as interconnection circuits
No ELV interconnections.
N/A
TRF No. IECEN60950_1C
Page 19 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
3.5.4
Data ports for additional equipment
TRF No. IECEN60950_1C
Result - Remark
Verdict
N/A
Page 20 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
4
PHYSICAL REQUIREMENTS
N/A
4.1
Stability
N/A
Angle of 10°
N/A
Test force (N) ........................................................ :
N/A
4.2
Mechanical strength
Pass
4.2.1
General
Class III Equipment.
N/A
4.2.2
Steady force test, 10 N
No hazard.
N/A
4.2.3
Steady force test, 30 N
No hazard.
N/A
4.2.4
Steady force test, 250 N
No hazard.
N/A
4.2.5
Impact test
N/A
Fall test
See above.
N/A
Swing test
See above.
N/A
4.2.6
Drop test; height (mm) .......................................... :
N/A
4.2.7
Stress relief test
N/A
4.2.8
Cathode ray tubes
No such tube.
N/A
Picture tube separately certified ........................... :
N/A
4.2.9
High pressure lamps
N/A
4.2.10
Wall or ceiling mounted equipment; force (N) ...... :
N/A
4.3
Design and construction
Pass
4.3.1
Edges and corners
N/A
4.3.2
Handles and manual controls; force (N) .............:
No such components
N/A
4.3.3
Adjustable controls
No such components
N/A
4.3.4
Securing of parts
N/A
4.3.5
Connection by plugs and sockets
No such components
No such components
4.3.6
Direct plug-in equipment
Class III Equipment.
N/A
N/A
Torque .................................................................. :
⎯
Compliance with the relevant mains plug standard
.............................................................................. :
N/A
4.3.7
Heating elements in earthed equipment
No heating elements.
N/A
4.3.8
Batteries
No batteries
N/A
- Overcharging of a rechargeable battery
N/A
- Unintentional charging of a non-rechargeable
battery
N/A
TRF No. IECEN60950_1C
Page 21 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
- Reverse charging of a rechargeable battery
N/A
- Excessive discharging rate for any battery
N/A
4.3.9
Oil and grease
4.3.10
Dust, powders, liquids and gases
4.3.11
Containers for liquids or gases
4.3.12
Flammable liquids ................................................ :
Insulation is not exposed to
oil, grease etc.
Equipment in intended use
not considered to be exposed
to dust, powders, liquids or
gases.
The equipment does not
contain liquid.
No flammable liquids in this
unit.
N/A
N/A
N/A
N/A
Quantity of liquid (l) .............................................. :
N/A
Flash point (°C) .................................................... :
N/A
4.3.13
Radiation
4.3.13.1
General
N/A
4.3.13.2
Ionizing radiation
N/A
4.3.13.3
No ionizing radiation.
N/A
Measured radiation (pA/kg) ................................. :
⎯
Measured high-voltage (kV) ................................. :
⎯
Measured focus voltage (kV) ............................... :
⎯
CRT markings ...................................................... :
⎯
Effect of ultraviolet (UV) radiation on materials
N/A
Part, property, retention after test, flammability
classification ......................................................... :
N/A
4.3.13.4
Human exposure to ultraviolet (UV) radiation ...... :
N/A
4.3.13.5
Laser (including LEDs)
N/A
Laser class ........................................................... :
⎯
4.3.13.6
Other types .......................................................... :
N/A
4.4
Protection against hazardous moving parts
N/A
4.4.1
General
4.4.2
Protection in operator access areas .................... :
N/A
4.4.3
Protection in restricted access locations ............. :
N/A
4.4.4
Protection in service access areas
N/A
4.5
Thermal requirements
Pass
4.5.1
General
Pass
4.5.2
Temperature tests
TRF No. IECEN60950_1C
No hazardous moving parts.
(see appended table 4.5)
N/A
Pass
Page 22 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Normal load condition per Annex L ...................... :
L7
4.5.3
Temperature limits for materials
(see appended table 4.5)
Pass
4.5.4
Touch temperature limits
(see appended table 4.5)
Pass
4.5.5
Resistance to abnormal heat ............................... :
(see appended table 4.5.5)
N/A
4.6
Openings in enclosures
4.6.1
Top and side openings
⎯
N/A
No internal hazardous live or
engergy hazard part.
N/A
⎯
Dimensions (mm) ................................................. :
4.6.2
Verdict
Bottoms of fire enclosures
N/A
⎯
Construction of the bottomm, dimensions (mm) .. :
(see appended table 4.6.1
and 4.6.2)
4.6.3
Doors or covers in fire enclosures
No door or covers provided in
the fire enclosure.
4.6.4
Openings in transportable equipment
N/A
4.6.4.1
Constructional design measures
N/A
N/A
⎯
Dimensions (mm) ................................................. :
4.6.4.2
Evaluation measures for larger openings
N/A
4.6.4.3
Use of metallized parts
N/A
4.6.5
Adhesives for constructional purposes
No adhesives used.
⎯
Conditioning temperature (°C), time (weeks) ....... :
4.7
Resistance to fire
4.7.1
Reducing the risk of ignition and spread of flame
N/A
Pass
Method 1 used.
Pass
Method 1, selection and application of components (see appended table 4.7)
wiring and materials
Pass
Method 2, application of all of simulated fault
condition tests
N/A
4.7.2
Conditions for a fire enclosure
4.7.2.1
Parts requiring a fire enclosure
4.7.2.2
Parts not requiring a fire enclosure
4.7.3
Materials
4.7.3.1
General
4.7.3.2
Materials for fire enclosures
TRF No. IECEN60950_1C
(see appended table 4.7)
N/A
N/A
Components are mounted on
materials of flammability
Class V-0
Pass
Pass
The PCB board is of
flammability V-0
Pass
N/A
Page 23 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
4.7.3.3
Materials for components and other parts outside
fire enclosures
4.7.3.4
Materials for components and other parts inside
fire enclosures
PCB rated V-0
4.7.3.5
Materials for air filter assemblies
No air filter assemblies.
N/A
4.7.3.6
Materials used in high-voltage components
No high-voltage components
N/A
TRF No. IECEN60950_1C
Result - Remark
Verdict
N/A
Pass
Page 24 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
Pass
5.1
Touch current and protective conductor current
N/A
5.1.1
General
5.1.2
Configuration of equipment under test (EUT)
N/A
5.1.2.1
Single connection to an a.c. mains supply
N/A
5.1.2.2
Redundant multiple connections to an a.c. mains
supply
N/A
5.1.2.3
Simultaneous multiple connections to an a.c. mains
supply
N/A
5.1.3
Test circuit
N/A
5.1.4
Application of measuring instrument
N/A
5.1.5
Test procedure
N/A
5.1.6
Test measurements
N/A
Class III equipment.
Verdict
N/A
Supply voltage (V) ................................................ :
⎯
Measured touch current (mA) .............................. :
⎯
Max. allowed touch current (mA) ......................... :
⎯
Measured protective conductor current (mA) ...... :
⎯
Max. allowed protective conductor current (mA) .. :
⎯
5.1.7
Equipment with touch current exceeding 3,5 mA
N/A
5.1.7.1
General ................................................................. :
N/A
5.1.7.2
Simultaneous multiple connections to the supply
N/A
5.1.8
Touch currents to telecommunication networks and Not connected to a
cable distribution systems and from
telecommunication network or
telecommunication networks
a cable distribution system.
N/A
5.1.8.1
Limitation of the touch current to a
telecommunication network or to a cable
distribution system
N/A
5.1.8.2
5.2
Supply voltage (V) ................................................ :
⎯
Measured touch current (mA) .............................. :
⎯
Max. allowed touch current (mA) ......................... :
⎯
Summation of touch currents from
telecommunication networks
N/A
a) EUT with earthed telecommunication ports ..... :
N/A
b) EUT whose telecommunication ports have no
reference to protective earth
N/A
Electric strength
N/A
TRF No. IECEN60950_1C
Page 25 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
5.2.1
General
(see appended table 5.2)
5.2.2
Test procedure
N/A
5.3
Abnormal operating and fault conditions
Pass
5.3.1
Protection against overload and abnormal
operation
Pass
5.3.2
Motors
No motor
N/A
5.3.3
Transformers
N/A
5.3.4
Functional insulation ............................................. :
5.3.5
Electromechanical components
5.3.6
Audio amplifiers in ITE ......................................... :
(see appended table 5.3 and
Annex C)
Method c).
Short Circuit tests, result see
appended table 5.3.
No electromechanical
components.
No such component.
N/A
5.3.7
Simulation of faults
(see appended table 5.3)
Pass
5.3.8
Unattended equipment
No such component used.
N/A
5.3.9
Compliance criteria for abnormal operating and
fault conditions
Pass
5.3.9.1
During the tests
Pass
5.3.9.2
After the tests
Pass
TRF No. IECEN60950_1C
Verdict
N/A
N/A
N/A
Page 26 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
6
CONNECTION TO TELECOMMUNICATION NETWORKS
N/A
6.1
Protection of telecommunication network service persons, and users of other
equipment connected to the network, from hazards in the equipment
N/A
6.1.1
Protection from hazardous voltages
N/A
6.1.2
Separation of the telecommunication network from earth
N/A
6.1.2.1
Requirements
N/A
(see appended table 5.2)
Verdict
Supply voltage (V) ................................................ :
⎯
Current in the test circuit (mA) ........................... :
⎯
6.1.2.2
Exclusions ............................................................ :
N/A
6.2
Protection of equipment users from overvoltages on telecommunication networks
N/A
6.2.1
Separation requirements
N/A
6.2.2
Electric strength test procedure
N/A
6.2.2.1
Impulse test
(see appended table 5.2)
N/A
6.2.2.2
Steady-state test
(see appended table 5.2)
N/A
6.2.2.3
Compliance criteria
N/A
6.3
Protection of the telecommunication wiring system from overheating
N/A
Max. output current (A) ........................................ :
⎯
Current limiting method ........................................ :
⎯
TRF No. IECEN60950_1C
Page 27 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
7
CONNECTION TO CABLE DISTRIBUTION SYSTEMS
N/A
7.1
General
N/A
7.2
Protection of cable distribution system service
persons, and users of other equipment connected
to the system, from hazardous voltages in the
equipment
N/A
7.3
Protection of equipment users from overvoltages
on the cable distribution system
N/A
7.4
Insulation between primary circuits and cable
distribution systems
N/A
7.4.1
General
N/A
7.4.2
Voltage surge test
(see appended table 5.2)
N/A
7.4.3
Impulse test
(see appended table 5.2)
N/A
TRF No. IECEN60950_1C
Result - Remark
The equipment doesn’t intend
to be connected to cable
distribution system.
Verdict
Page 28 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
A
ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE
N/A
A.1
Flammability test for fire enclosures of movable
equipment having a total mass exceeding 18 kg,
and of stationary equipment (see 4.7.3.2)
N/A
A.1.1
Samples ................................................................ :
⎯
Wall thickness (mm).............................................. :
⎯
A.1.2
Conditioning of samples; temperature (°C) ......... :
N/A
A.1.3
Mounting of samples ............................................ :
N/A
A.1.4
Test flame (see IEC 60695-11-3)
N/A
Flame A, B, C or D ............................................... :
Verdict
⎯
A.1.5
Test procedure
N/A
A.1.6
Compliance criteria
N/A
Sample 1 burning time (s)..................................... :
⎯
Sample 2 burning time (s)..................................... :
⎯
Sample 3 burning time (s)..................................... :
⎯
A.2
Flammability test for fire enclosures of movable equipment having a total mass not
exceeding 18 kg, and for material and components located inside fire enclosures
(see 4.7.3.2 and 4.7.3.4)
A.2.1
Samples, material ................................................. :
⎯
Wall thickness (mm).............................................. :
⎯
A.2.2
Conditioning of samples; temperature (°C) ......... :
N/A
A.2.3
Mounting of samples ............................................ :
N/A
A.2.4
Test flame (see IEC 60695-11-4)
N/A
Flame A, B or C ................................................... :
N/A
⎯
A.2.5
Test procedure
N/A
A.2.6
Compliance criteria
N/A
A.2.7
Sample 1 burning time (s)..................................... :
⎯
Sample 2 burning time (s)..................................... :
⎯
Sample 3 burning time (s)..................................... :
⎯
Alternative test acc. to IEC 60695-11-5, cl. 5 and 9
N/A
Sample 1 burning time (s)..................................... :
⎯
Sample 2 burning time (s)..................................... :
⎯
Sample 3 burning time (s)..................................... :
⎯
A.3
Hot flaming oil test (see 4.6.2)
N/A
A.3.1
Mounting of samples
N/A
TRF No. IECEN60950_1C
Page 29 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
A.3.2
Test procedure
N/A
A.3.3
Compliance criterion
N/A
B
ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS (see 4.7.2.2 and
5.3.2)
N/A
B.1
General requirements
N/A
Position ................................................................ :
⎯
Manufacturer ........................................................ :
⎯
Type ..................................................................... :
⎯
Rated values ....................................................... :
⎯
B.2
Test conditions
N/A
B.3
Maximum temperatures
(see appended table 5.3)
N/A
B.4
Running overload test
(see appended table 5.3)
N/A
B.5
Locked-rotor overload test
N/A
Test duration (days) ............................................. :
⎯
Electric strength test: test voltage (V) .................. :
⎯
B.6
Running overload test for d.c. motors in secondary
circuits
N/A
B.6.1
General
N/A
B.6.2
Test procedure
N/A
B.6.3
Alternative test procedure
N/A
B.6.4
Electric strength test; test voltage (V) .................. :
N/A
B.7
Locked-rotor overload test for d.c. motors in
secondary circuits
N/A
B.7.1
General
N/A
B.7.2
Test procedure
N/A
B.7.3
Alternative test procedure
N/A
B.7.4
Electric strength test; test voltage (V) ................. :
N/A
B.8
Test for motors with capacitors
(see appended table 5.3)
N/A
B.9
Test for three-phase motors
(see appended table 5.3)
N/A
B.10
Test for series motors
Operating voltage (V) ........................................... :
C
ANNEX C, TRANSFORMERS (see 1.5.4 and 5.3.3)
N/A
⎯
N/A
Position ................................................................ :
⎯
Manufacturer ........................................................ :
⎯
TRF No. IECEN60950_1C
Page 30 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
Type ..................................................................... :
⎯
Rated values ....................................................... :
⎯
Method of protection ............................................. :
⎯
C.1
Overload test
(see appended table 5.3)
N/A
C.2
Insulation
(see appended table 5.2)
N/A
Protection from displacement of windings ............:
N/A
D
ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS
(see 5.1.4)
N/A
D.1
Measuring instrument
N/A
D.2
Alternative measuring instrument
N/A
E
ANNEX E, TEMPERATURE RISE OF A WINDING (see 1.4.13)
N/A
F
ANNEX F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES
(see 2.10 and Annex G)
N/A
G
ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM
CLEARANCES
N/A
G.1
Clearances
N/A
G.1.1
General
N/A
G.1.2
Summary of the procedure for determining
minimum clearances
N/A
G.2
Determination of mains transient voltage (V)
N/A
G.2.1
AC mains supply .................................................. :
N/A
G.2.2
Earthed d.c. mains supplies ................................. :
N/A
G.2.3
Unearthed d.c. mains supplies ............................ :
N/A
G.2.4
Battery operation .................................................. :
N/A
G.3
Determination of telecommunication network
transient voltage (V) ............................................. :
N/A
G.4
Determination of required withstand voltage (V)
N/A
G.4.1
Mains transients and internal repetitive peaks .... :
N/A
G.4.2
Transients from telecommunication networks ..... :
N/A
G.4.3
Combination of transients
N/A
G.4.4
Transients from cable distribution systems
N/A
G.5
Measurement of transient voltages (V)
N/A
a) Transients from a mains supply
N/A
TRF No. IECEN60950_1C
Page 31 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
For an a.c. mains supply
N/A
For a d.c. mains supply
N/A
b) Transients from a telecommunication network
N/A
G.6
Determination of minimum clearances ................ :
N/A
H
ANNEX H, IONIZING RADIATION (see 4.3.13)
N/A
J
ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6)
N/A
⎯
Metal(s) used ....................................................... :
K
ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.8)
N/A
K.1
Making and breaking capacity
N/A
K.2
Thermostat reliability; operating voltage (V) ........ :
N/A
K.3
Thermostat endurance test; operating voltage (V)
.............................................................................. :
N/A
K.4
Temperature limiter endurance; operating voltage
(V) ........................................................................ :
N/A
K.5
Thermal cut-out reliability
N/A
K.6
Stability of operation
L
ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL
BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.2)
Pass
L.1
Typewriters
N/A
L.2
Adding machines and cash registers
N/A
L.3
Erasers
N/A
L.4
Pencil sharpeners
N/A
L.5
Duplicators and copy machines
N/A
L.6
Motor-operated files
N/A
L.7
Other business equipment
Pass
M
ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1)
N/A
M.1
Introduction
N/A
M.2
Method A
N/A
M.3
Method B
N/A
M.3.1
Ringing signal
N/A
M.3.1.1
Frequency (Hz) .................................................... :
TRF No. IECEN60950_1C
(see appended table 5.3)
N/A
⎯
Page 32 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
M.3.1.2
Voltage (V) ........................................................... :
⎯
M.3.1.3
Cadence; time (s), voltage (V) ............................. :
⎯
M.3.1.4
Single fault current (mA) ...................................... :
⎯
M.3.2
Tripping device and monitoring voltage ............... :
N/A
M.3.2.1
Conditions for use of a tripping device or a
monitoring voltage
N/A
M.3.2.2
Tripping device
N/A
M.3.2.3
Monitoring voltage (V) .......................................... :
N/A
N
ANNEX N, IMPULSE TEST GENERATORS (see 1.5.7.2, 1.5.7.3, 2.10.3.9, 6.2.2.1,
7.3.2, 7.4.3 and Clause G.5)
N/A
N.1
ITU-T impulse test generators
N/A
N.2
IEC 60065 impulse test generator
N/A
P
ANNEX P, NORMATIVE REFERENCES
Q
ANNEX Q, Voltage dependent resistors (VDRs) (see 1.5.9.1)
N/A
a) Preferred climatic categories ........................... :
N/A
b) Maximum continuous voltage .......................... :
N/A
c) Pulse current .................................................... :
N/A
R
ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL
PROGRAMMES
N/A
R.1
Minimum separation distances for unpopulated
coated printed boards (see 2.10.6.2)
N/A
R.2
Reduced clearances (see 2.10.3)
N/A
S
ANNEX S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3)
N/A
S.1
Test equipment
N/A
S.2
Test procedure
N/A
S.3
Examples of waveforms during impulse testing
N/A
T
ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER
(see 1.1.2)
N/A
⎯
See separate test report
TRF No. IECEN60950_1C
Verdict
⎯
Page 33 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
U
ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED
INSULATION (see 2.10.5.4)
See separate test report
Verdict
N/A
⎯
V
ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1)
N/A
V.1
Introduction
N/A
V.2
TN power distribution systems
N/A
W
ANNEX W, SUMMATION OF TOUCH CURRENTS
N/A
W.1
Touch current from electronic circuits
N/A
W.1.1
Floating circuits
N/A
W.1.2
Earthed circuits
N/A
W.2
Interconnection of several equipments
N/A
W.2.1
Isolation
N/A
W.2.2
Common return, isolated from earth
N/A
W.2.3
Common return, connected to protective earth
N/A
X
ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS (see clause
C.1)
N/A
X.1
Determination of maximum input current
N/A
X.2
Overload test procedure
N/A
Y
ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see 4.3.13.3)
N/A
Y.1
Test apparatus ..................................................... :
N/A
Y.2
Mounting of test samples ..................................... :
N/A
Y.3
Carbon-arc light-exposure apparatus .................. :
N/A
Y.4
Xenon-arc light exposure apparatus .................... :
N/A
Z
ANNEX Z, OVERVOLTAGE CATEGORIES (see 2.10.3.2 and Clause G.2)
N/A
AA
ANNEX AA, MANDREL TEST (see 2.10.5.8)
N/A
BB
ANNEX BB, CHANGES IN THE SECOND EDITION
TRF No. IECEN60950_1C
⎯
Page 34 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
1.5.1
TABLE: List of critical components
Object/part No.
PCB
Result - Remark
Manufacturer/
trademark
CHINA
CIRCUIT
TECHNOLOGY
(SHANTOU)
CORP
Verdict
Pass
Type/model
Technical data
2
Standard
(Edition / year)
EN 60950-1
1.0mm
thickness
6 layer, FR4
Mark(s) of
conformity1)
UL E99006 and
test with
appliance
105 ℃;V-0
1
) An asterisk indicates a mark which assures the agreed level of surveillance
Supplementary information:--
1.6.2
TABLE: Electrical data (in normal conditions)
U (V)
--
I (A)
--
Irated (A)
--
P (W)
Fuse #
--
--
N/A
Ifuse (A)
--
Condition/status
--
Supplementary information:--
2.10.3 and
2.10.4
TABLE: Clearance and creepage distance measurements
Clearance (cl) and creepage
distance (cr) at/of/between:
U peak
(V)
U r.m.s.
(V)
Required cl
(mm)
N/A
cl
(mm)
Required cr
(mm)
cr
(mm)
---
--
--
--
--
--
--
Supplementary information:--
2.10.5
TABLE: Distance through insulation measurements
Distance through insulation (DTI) at/of:
U peak
(V)
--
--
Supplementary information:--
TRF No. IECEN60950_1C
U rms
(V)
--
N/A
Test
voltage
(V)
Required DTI
(mm)
--
--
DTI
(mm)
--
Page 35 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
4.3.8
TABLE: Batteries
Result - Remark
Verdict
N/A
The tests of 4.3.8 are applicable only when appropriate battery
data is not available
--
--
Is it possible to install the battery in a reverse polarity position?
--
--
Non-rechargeable batteries
Discharging
Meas.
current
Manuf.
Specs.
Rechargeable batteries
Unintentional
charging
Charging
Meas.
current
Discharging
Manuf.
Specs.
Meas.
current
Reversed
charging
Manuf.
Specs.
Max.
current
during
normal
condition
--
--
--
--
--
--
--
Meas.
Manuf.
current Specs.
---
Max.
current
during
fault
condition
--
--
--
--
--
--
--
--
--
-Test results:
--
Verdict
- Chemical leaks
--
--
- Explosion of the battery
--
--
- Emission of flame or expulsion of molten metal
--
--
- Electric strength tests of equipment after completion of tests
--
--
Supplementary information:--
4.5
TABLE: Thermal requirements
Pass
Supply voltage (V) .......................... : A: 3.4Vd.c. B: 4.5Vd.c.
⎯
Ambient Tmin (°C) ............................. :
⎯
Ambient Tmax (°C) ............................ :
⎯
Maximum measured temperature T of part/at::
Allowed
Tmax
(°C)
T (°C)
PCB
32.1
32.7
105
ambient
25
25
--
Supplementary information:
Temperature T of winding:
-TRF No. IECEN60950_1C
t1 (°C)
--
R1 (Ω)
--
t2 (°C)
--
R2 (Ω)
--
T (°C)
--
Allowed
Tmax (°C)
Insulatio
n class
--
--
Page 36 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
Supplementary information:
The temperatures were measured by thermal couple method under worst case normal mode as described
in 1.6.2 at voltage described in 1.4.5.
With max. ambient temperature specified as 25°C, therefore, the maximum temperature is as follows:
Components with:
- PCB Tmax = 105°C
-Tamb=25°C
4.5.5
TABLE: Ball pressure test of thermoplastic parts
N/A
Allowed impression diameter (mm) .....................: ≤ 2 mm
⎯
Part
Test temperature Impression diameter
(mm)
(°C)
--
--
--
Supplementary information:--
4.7
TABLE: Resistance to fire
Part
N/A
Manufacturer of
material
--
--
Type of material
--
Thickness Flammability
(mm)
class
--
--
Evidence
--
Supplementary information:--
5.2
TABLE: Electric strength tests, impulse tests and voltage surge tests
Test voltage applied between:
N/A
Voltage shape Test voltage
(AC, DC,
(V)
impulse, surge)
Breakdow
n
Yes / No
Functional:
--
--
--
--
--
--
--
--
--
--
Basic/supplementary:
-Reinforced:
-Supplementary information:--
5.3
TABLE: Fault condition tests
Ambient temperature (°C) ...................................:
TRF No. IECEN60950_1C
Pass
25
⎯
Page 37 of 45
Report No.SH11070685-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
⎯
Power source for EUT: Manufacturer, model/type,
output rating .........................................................:
Component
No.
C142
Fault
Short-circuit
Supply
voltage
(V)
In the
Test
time
Fuse #
1min
--
Fuse
current
(A)
--
Observation
No high temperature. No hazard.
module
Supplementary information:
S-C: short circuit, O-C: open circuit, O/L: overload
During fault condition where the fuse opened, the same result was obtained with all fuse types.
During fault condition where the fuse not opened, the test was repeated three times.
TRF No. IECEN60950_1C
Page 38 of 45
Report No. SH11010071-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
Appendix
Amendment A11 to EN 60950-1:2009
ZA
Annex ZA (normative) - Normative references to international publications with their
corresponding European publications
N/A
ZB
Annex ZB (normative) - Special national conditions
N/A
1.2.13.14 In Norway and Sweden, for requirements see
1.7.2.1 and 7.3 of this annex.
N/A
1.5.7.1
Replace:
In Finland, Norway and Sweden, resistors
bridging BASIC INSULATION in CLASS I PLUGGABLE
EQUIPMENT TYPE A must comply with the
requirements in 1.5.7.1. In addition when a single
resistor is used, the resistor must withstand the
resistor test in 1.5.7.2.
N/A
1.7.2.1
In Norway and Sweden, the screen of the cable
distribution system is normally not earthed at the
entrance of the building and there is normally no
equipotential bonding system within the building.
Therefore the protective earthing of the building
installation need to be isolated from the screen of a
cable distribution system.
It is however accepted to provide the insulation
external to the equipment by an adapter or an
interconnection cable with galvanic isolator, which
may be provided by e.g. a retailer.
The user manual shall then have the following or
similar information in Norwegian and Swedish
language respectively, depending on in what
country the equipment is intended to be used in:
“Equipment connected to the protective earthing
of the building installation through the mains
connection or through other equipment with a
connection to protective earthing – and to a
cable distribution system using coaxial cable,
may in some circumstances create a fire hazard.
Connection to a cable distribution system has
therefore to be provided through a device
providing electrical isolation below a certain
frequency range (galvanic isolator, see EN
60728-11).”
N/A
NOTE In Norway, due to regulation for installations of cable
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz,
for 1 min.
Translation to Norwegian (the Swedish text will
also be accepted in Norway):
TRF No. IECEN60950_1C
Page 39 of 45
Report No. SH11010071-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet utstyr –
og er tilkoplet et kabel-TV nett, kan forårsake
brannfare. For å unngå dette skal det ved
tilkopling av utstyret til kabel-TV nettet
installeres en galvanisk isolator mellom utstyret
og kabel- TV nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via
jordat vägguttag och/eller via annan utrustning
och samtidigt är kopplad till kabel-TV nät kan i
vissa fall medfőra risk főr brand. Főr att undvika
detta skall vid anslutning av utrustningen till
kabel-TV nät galvanisk isolator finnas mellan
utrustningen och kabel-TV nätet.”
1.7.5
Add for Denmark:
For CLASS II EQUIPMENT the socket outlet shall be in
accordance with Standard Sheet DKA 1-4a.
N/A
7.3
Delete the existing SNC for Norway and Sweden
N/A
Add for Norway and Sweden:
In Norway and Sweden, for requirements see
1.2.13.14 and 1.7.2.1 of this annex
N/A
ZC
Annex ZC (normative) – A-deviations
N/A
1.5.1
Sweden
Delete the A-deviation.
N/A
1.7.2.1
Denmark
Delete the A-deviation.
Denmark
Delete the A-deviation.
N/A
Denmark
Delete the A-deviation.
N/A
1.7.5
5.1.7.1
N/A
Amendment A1 to IEC 60950-1:2009 / EN 60950-1:2010
1.5.9.4
Resistors bridging functional insulation, basic
insulation or supplementary insulation
Resistors bridging double insulation or reinforced
insulation between the a.c.
mains supply and other circuits
Bridging of basic insulation by a VDR
1.7
Markings and instructions
1.5.7.1
1.5.7.2
TRF No. IECEN60950_1C
N/A
N/A
N/A
Page 40 of 45
Report No. SH11010071-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
1.7.1
Power rating
N/A
1.7.1
Power rating and identification markings
N/A
1.7.1.1
Power rating markings
N/A
Power rating markings
N/A
Rated voltage(s) or voltage range(s) (V) .............:
N/A
Symbol for nature of supply, for d.c. only ............:
N/A
Rated frequency or rated frequency range (Hz) ..:
N/A
Rated current (mA or A) .......................................:
N/A
Additonal markings and symbols .........................:
N/A
Identification markings
N/A
Manufacturer's name or trade-mark or identification
mark .....................................................................:
N/A
Manufacturer's model identification or type
reference ..............................................................:
N/A
Symbol for Class II equipment only, except where it
is forbidden ..........................................................:
N/A
Additional identification markings ........................:
N/A
1.7.7.1
Protective earthing and bonding terminals
N/A
2.1.1.5
Energy hazards ....................................................:
N/A
2.1.1.7
Discharge of capacitors in equipment
N/A
1.7.1.2
Measured voltage (V); time-constant (s) .............:
2.1.1.8
⎯
Energy hazards - d.c. mains supplies
N/A
A hazardous energy level exists if the voltage, U, is
2 V or more, and the stored energy, E, is 20 J or
more
N/A
2.4.1
General requirements
N/A
2.5
Limited power sources
N/A
b) a linear or non-linear impedance limits the
output
N/A
c) a regulating network, or an integrated circuit (IC)
current limiter, limits the output
N/A
Functional earthing
N/A
2.6.2
TRF No. IECEN60950_1C
Page 41 of 45
Report No. SH11010071-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
2.6.5.6
Corrosion resistance
N/A
2.8.4
Fail-safe operation
N/A
2.8.7
Switches, relays and their related circuits
N/A
2.8.7.1
Separation distances for contact gaps and their
related circuits
N/A
2.8.7.2
Overload test
N/A
2.8.7.3
Endurance test
N/A
2.8.7.4
Electric strength test
N/A
2.9.2
Humidity conditioning
N/A
Relative humidity (%), temperature (°C) ................ :
⎯
2.10.5.5
Cemented joints
N/A
4.2.1
General
N/A
4.2.5
Impact test
N/A
4.2.6
Drop test height (mm) ........................................... :
N/A
4.2.7
Stress relief test
N/A
4.2.11
Rotating solid media
N/A
4.3.13.3
Effect of ultraviolet (UV) radiation on materials
N/A
4.3.13.4
Human exposure to ultraviolet (UV) radiation
N/A
4.3.13.5
Lasers (including laser diodes) and LEDs
N/A
4.3.13.5.1 Lasers (including laser diodes)
N/A
4.3.13.5.2 Light emitting diodes (LEDs)
N/A
4.4.1
General
N/A
4.4.2
Protection in operator access areas
N/A
4.4.5
Protection against moving fan blades
N/A
4.4.5.1
General
N/A
4.4.5.2
Protection for users
N/A
4.4.5.3
Protection for service persons
N/A
TRF No. IECEN60950_1C
Page 42 of 45
Report No. SH11010071-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
6.1.2.1
Requirements
N/A
6.2.1
Separation requirements
N/A
6.2.2.1
Impulse test
N/A
B
Annex B – Motor tests under abnormal conditions
N/A
B.1
General requirements
N/A
D
Annex D – Measuring instruments for touch current tests
N/A
F
Annex F – Measurement of clearances and creepage distances
N/A
G
Annex G – Alternative method for determining minimum clearances
N/A
G.1.2
Summary of the procedure for determining
minimum clearances
N/A
G.6
Determination of minimum clearances
N/A
J
Annex J – Table of electrochemical potentials
N/A
Metal(s) used ......................................................... :
⎯
M
Annex M – Criteria for telephone ringing signals
N/A
M.2
Method A
N/A
P
Annex P – Normative references
N/A
U
Annex U – Insulated winding wires for use without interleaved insulation
N/A
Y
Annex Y – Ultraviolet light conditioning test
N/A
Y.1
Test apparatus ....................................................... :
N/A
Y.3
Carbon-arc light-exposure apparatus .................... :
N/A
Y.4
Xenon-arc light-exposure apparatus ..................... :
N/A
CC
Annex CC (normative) - Evaluation of integrated circuit (IC) current limiters
N/A
CC.1
Integrated circuit (IC) current limiters
N/A
TRF No. IECEN60950_1C
Page 43 of 45
Report No. SH11010071-001
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
CC.2
Test program 1
N/A
CC.3
Test program 2
N/A
DD
N/A
DD.1
Annex DD (normative) - Requirements for the mounting means of rack-mounted
equipment
General
DD.2
Mechanical strength test, variable N
N/A
DD.3
N/A
DD.4
Mechanical strength test, 250 N, including end
stops
Compliance
N/A
EE
Annex EE (normative) - Household and home/office document/media shredders
N/A
EE.1
General
N/A
EE.2
Markings and instructions
N/A
EE.3
Inadvertent reactivation
N/A
EE.4
Disconnection of power to hazardous moving parts
N/A
EE.5
Protection against hazardous moving parts
N/A
ZA
Annex ZA (normative) - Normative references to international publications with their
corresponding European publications
N/A
ZB
Annex ZB (normative) - Special national conditions
N/A
1.5.7.1
In Finland, Norway and Sweden
No changes needed
N/A
6.1.2.1
In Finland, Norway and Sweden, add the
following text between the first and second
paragraph of the compliance clause:
If this insulation is solid, including insulation
forming part of a component, it shall at least
consist of either
- two layers of thin sheet material, each of which
shall pass the electric strength test below, or
- one layer having a distance through insulation of
at least 0,4 mm, which shall pass the electric
strength test below.
N/A
TRF No. IECEN60950_1C
N/A
N/A
Page 44 of 45
Report No. SH11010071-001
IEC/EN 60950-1
Clause
Requirement + Test
Alternatively for components, there is no distance
through insulation requirement for the insulation
consisting of an insulating compound completely
filling the casing, so that CLEARANCES and
CREEPAGE DISTANCES do not exist, if the component
passes the electric strength test in accordance with
the compliance clause below and in addition
- passes the tests and inspection criteria of 2.10.11
with an electric strength test of 1,5 kV multiplied by
1,6 (the electric strength test of 2.10.10 shall be
performed using 1,5 kV), and
- is subject to ROUTINE TESTING for electric strength
during manufacturing, using a test voltage of 1,5
kV.
It is permitted to bridge this insulation with an
optocoupler complying with 2.10.5.4 b).
It is permitted to bridge this insulation with a
capacitor complying with EN 60384-14:2005,
subclass Y2.
A capacitor classified Y3 according to EN 6038414:2005, may bridge this insulation under the
following conditions:
- the insulation requirements are satisfied by
having a capacitor classified Y3 as defined by EN
60384-14, which in addition to the Y3 testing, is
tested with an impulse test of 2,5 kV defined in EN
60950-1:2006, 6.2.2.1;
- the additional testing shall be performed on all the
test specimens as described in EN 60384-14;
- the impulse test of 2,5 kV is to be performed
before the endurance test in EN 60384-14, in the
sequence of tests as described in EN 60384-14.
TRF No. IECEN60950_1C
Result - Remark
Verdict
N/A
N/A
N/A
Page 45 of 45
Photograph
For model SIM900R:
Report No. SH11070685-001
PHOTO NO.1
PHOTO NO.2
TRF No. IECEN60950_1C
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project