YORK DR 036, 048, 060, 072 Air Conditioning Unit Technical Guide
The YORK Sunline MagnaDRY™ units are convertible single package air conditioners with a common cabinet and a common roof curb for the 3, 4, 5 and 6 ton sizes. The units were designed for light commercial and commercial applications. They can easily be installed on a roof curb, slab, roof jack or frame. They can be easily converted for bottom or side air discharge configuration. All units are manufactured under the quality standards of ISO9001.
PDF
Download
Document
Advertisement
Advertisement
036-21685-002-A-1105 ® DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE YORK Sunline MagnaDRY™ units are convertible single package air conditioners with a common cabinet and a common roof curb for the 3, 4, 5 and 6 ton sizes. The units were designed for light commercial and commercial applications. They can easily be installed on a roof curb, slab, roof jack or frame. All units include: AIR CONDITIONERS • Powder Paint finish that meets ASTM-B-117 1000 hour salt spray standards • Permanently lubricated motors • Bottom or side air discharge configuration capability (field convertible) • Manufactured under the quality standards of ISO9001 • SimplicityTM Control Board • Copper tube/aluminum fin coils • Easy access to all components • Rigging holes in base rails for lifting • Fork lift slots on three sides • Single point power connection • Complete factory package - tested, charged and wired • CSA agency listing on all units DR 036, 048, 060 and 072 3, 4, 5 and 6 NOMINAL TONS 13.0 SEER 10.4 EER WARRANTY • Factory Limited Parts Warranty • One-year parts warranty • A Five-year parts warranty on the compressor and electric heat elements. • Ten-year parts warranty on the gas-fired heat exchangers. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 036-21685-002-A-1105 TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Tbl. # PRODUCT NOMENCLATURE . . . . . . . . . . . . . . . . . 4 7 DR048 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED INLET) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 8 DR048 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED DISCHARGE) . . . . . . . . . . . . . . . . . . . . . . . 19 9 DR060 & 072 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED INLET) . . . . . . . . . . . . . . . . 20 FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 FACTORY-INSTALLED OPTIONS . . . . . . . . . . . . . 13 FIELD-INSTALLED ACCESSORIES . . . . . . . . . . . 14 GUIDE SPECIFICATIONS . . . . . . . . . . . . . . . . . . . 52 LIST OF FIGURES Fig. # Pg. # 10 DR060 & 072 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED DISCHARGE) . . . . . . . . . . 20 11 DR060 & 072 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED INLET) . . . . . . . . . . . . . . . . . . 21 Pg. # 1 UNIT CUTAWAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 12 DR060 & 072 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED DISCHARGE) . . . . . . . . . . . . . 21 2 DR036 MOISTURE REMOVAL - REHEAT MODE . . 31 13 CAPACITY RATINGS . . . . . . . . . . . . . . . . . . . . . . . . 22 3 DR048 MOISTURE REMOVAL - REHEAT MODE . . 31 14 GAS HEAT RATINGS . . . . . . . . . . . . . . . . . . . . . . . . 22 4 DR060 MOISTURE REMOVAL - REHEAT MODE . . 32 15 2 STAGE GAS HEAT RATINGS . . . . . . . . . . . . . . . . 22 5 DR072 MOISTURE REMOVAL - REHEAT MODE . . 32 6 TYPICAL FIELD POWER & CONTROL WIRING . . . 45 16 DR036 COOLING CAPACITIES (3 TON) NORMAL MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 7 UNIT DIMENSIONS (3 - 6 TON COOLING ONLY/ ELECTRIC HEAT) FRONT VIEW . . . . . . . . . . . . . . . 46 8 UNIT DIMENSIONS (3 - 6 TON COOLING/GAS HEAT) FRONT VIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 9 UNIT WITH ECONOMIZER RAINHOOD . . . . . . . . . . 47 10 UNIT WITH FIXED OUTDOOR AIR/MOTORIZED DAMPER RAINHOOD . . . . . . . . . . . . . . . . . . . . . . . . 47 11 UNIT DIMENSIONS (REAR VIEW) . . . . . . . . . . . . . . 48 12 DISCONNECT/BLOWER ACCESS LOCATION . . . . 48 13 TYPICAL APPLICATIONS . . . . . . . . . . . . . . . . . . . . . 49 14 FOUR AND SIX POINT LOADING . . . . . . . . . . . . . . 50 15 ROOF CURB DIMENSIONS . . . . . . . . . . . . . . . . . . . 51 LIST OF TABLES Tbl. # 1 2 3 17 DR036 COOLING CAPACITIES (3 TON) REHEAT MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 18 DR048 COOLING CAPACITIES (4 TON) NORMAL MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 19 DR048 COOLING CAPACITIES (4 TON) REHEAT MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 20 DR060 COOLING CAPACITIES (5 TON) NORMAL MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 21 DR060 COOLING CAPACITIES (5 TON) REHEAT MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 22 DR072 COOLING CAPACITIES (6 TON) NORMAL MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 23 DR072 COOLING CAPACITIES (6 TON) REHEAT MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 24 SUPPLY AIR BLOWER PERFORMANCE (DR036 BELT DRIVE) - SIDE DUCT APPLICATION . . . . . . . 33 Pg. # DR036 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED INLET) . . . . . . . . . . . . . . . . 16 DR036 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED DISCHARGE) . . . . . . . . . . 16 DR036 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED INLET) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 25 SUPPLY AIR BLOWER PERFORMANCE (DR036 BELT DRIVE) - BOTTOM DUCT APPLICATION . . . . 34 26 SUPPLY AIR BLOWER PERFORMANCE (DR048 BELT DRIVE) - SIDE DUCT APPLICATION . . . . . . . 35 27 SUPPLY AIR BLOWER PERFORMANCE (DR048 BELT DRIVE) - BOTTOM DUCT APPLICATION . . . . 36 28 SUPPLY AIR BLOWER PERFORMANCE (DR060 & DR072 BELT DRIVE) - SIDE DUCT APPLICATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 4 DR036 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED DISCHARGE) . . . . . . . . . . . . . . . . . . . . . . . 17 5 DR048 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED INLET) . . . . . . . . . . . . . . . . 18 29 SUPPLY AIR BLOWER PERFORMANCE (DR060 & DR072 BELT DRIVE) - BOTTOM DUCT APPLICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 6 DR048 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED DISCHARGE) . . . . . . . . . . 18 30 BELT DRIVE BLOWER MOTOR AND DRIVE DATA 39 2 Unitary Products Group 036-21685-002-A-1105 LIST OF TABLES - CONTINUED Tbl. # Pg. # Tbl. # Pg. # 31 STATIC RESISTANCES . . . . . . . . . . . . . . . . . . . . . . 39 37 PHYSICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 32 ELECTRIC HEATER CFM LIMITATIONS . . . . . . . . . 39 38 ELECTRIC HEAT CORRECTION FACTORS . . . . . . 44 33 ELECTRICAL DATA - DR036 AND DR048 W/O POWERED CONVENIENCE OUTLET . . . . . . . . . . . 40 39 VOLTAGE LIMITATIONS . . . . . . . . . . . . . . . . . . . . . 44 34 ELECTRICAL DATA - DR060 AND DR072 W/O POWERED CONVENIENCE OUTLET . . . . . . . . . . . 41 41 MINIMUM CLEARANCES . . . . . . . . . . . . . . . . . . . . . 48 35 ELECTRICAL DATA - DR036 AND DR048 WITH POWERED CONVENIENCE OUTLET . . . . . . . . . . . 42 36 ELECTRICAL DATA - DR060 AND DR072 WITH POWERED CONVENIENCE OUTLET . . . . . . . . . . . 43 Unitary Products Group 40 UTILITIES ENTRY . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 42 DR 4 AND 6 POINT LOADS WEIGHT DISTRIBUTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 43 CENTER OF GRAVITY . . . . . . . . . . . . . . . . . . . . . . . 50 44 OPERATING WEIGHTS (LBS.) . . . . . . . . . . . . . . . . . 51 3 036-21685-002-A-1105 PRODUCT NOMENCLATURE 7RQ6XQOLQH0DJQD'5<0RGHO1XPEHU1RPHQFODWXUH ' 5 1 $ $ $$ 3URGXFW*HQHUDWLRQ 3URGXFW&DWHJRU\ )LUVW*HQHUDWLRQ ' $LU&RQG6LQJOH3DFNDJH 9ROWDJH 3URGXFW,GHQWLILHU 5 5+LJK(IILFLHQF\5HKHDW 1RPLQDO&RROLQJ &DSDFLW\0%+ ,QVWDOODWLRQ2SWLRQV $ 1R2SWLRQV,QVWDOOHG % 2SWLRQ & 2SWLRQ ' 2SWLRQV ( 2SWLRQ ) 2SWLRQ * 2SWLRQV + 2SWLRQV - 2SWLRQV . 2SWLRQV / 2SWLRQV 0 2SWLRQV 1 2SWLRQV 3 2SWLRQV 4 2SWLRQV 5 2SWLRQV 6 2SWLRQ 7 2SWLRQV 8 2SWLRQV 9 2SWLRQV : 2SWLRQV ; 2SWLRQV < 2SWLRQV = 2SWLRQV 7RQ 7RQ 7RQ 7RQ +HDW7\SH1RPLQDO+HDW&DSDFLW\ & &RROLQJ2QO\6XLWDEOHIRUILHOGLQVWDOOHGHOHFWULFKHDW *DV+HDW2SWLRQV 1 1 1 1 ' ' 6 6 6 6 7 7 0%+2XWSXW$OXPLQL]HG6WHHO6WDJH 0%+2XWSXW$OXPLQL]HG6WHHO6WDJH 0%+2XWSXW$OXPLQL]HG6WHHO6WDJH 0%+2XWSXW$OXPLQL]HG6WHHO6WDJH 0%+2XWSXW$OXPLQL]HG6WHHO6WDJH 0%+2XWSXW$OXPLQL]HG6WHHO6WDJH 0%+2XWSXW6WDLQOHVV6WHHO6WDJH 0%+2XWSXW6WDLQOHVV6WHHO6WDJH 0%+2XWSXW6WDLQOHVV6WHHO6WDJH 0%+2XWSXW6WDLQOHVV6WHHO6WDJH 0%+2XWSXW6WDLQOHVV6WHHO6WDJH 0%+2XWSXW6WDLQOHVV6WHHO6WDJH 6HH1H[W3DJH 2SWLRQV (OHFWULF+HDW2SWLRQV ( ( ( ( ( ( $GGLWLRQDO2SWLRQV N:(OHFWULF+HDW N:(OHFWULF+HDW N:(OHFWULF+HDW N: (OHFWULF+HDW N:(OHFWULF+HDW N:(OHFWULF+HDW 'LVFRQQHFW 1RQ3ZU G&RQY2XOWHW 6PRNH'HWHFWRU6$ 6PRNH'HWHFWRU5$ 3ZU G&RQY2XWOHW '7 0%+2XWSXWRQ0RGHOV $LUIORZ 1 3 5 < 4 %HOW'ULYH %HOW'ULYH6LQJOH,QSXW(FRQR %HOW'ULYH0RWRUL]HG'DPSHU %HOW'ULYH%$65HDG\(FRQ1R%$6&RQWUROOHUZ3OHDWHG)LOWHUV Unitary Products Group 036-21685-002-A-1105 PRODUCT NOMENCLATURE - Continued 3-6T Sunline Model Number Nomenclature Standard Cabinet AA AB AC AD AE AF AG AH AJ AK AL AM AN AS CA CB CC CD CE CF CG CH CJ CK CL CM CN CP CQ CR CS CT CU CV CW CX JA JB JC JD JE JF JG JH JJ JK JL JM JN JP None Phase Monitor Coil Guard Dirty Filter Switch Phase Monitor & Coil Guard Phase Monitor & Dirty Filter Switch Coil Guard & Dirty Filter Switch Phase Monitor, Coil Guard, & Dirty Filter Switch SS Drain Pan SS Drain Pan & Phase Monitor SS Drain Pan & Coil Guard SS Drain Pan & Dirty Filter Switch SS Drain Pan, Phase Monitor, Coil Guard & Dirty Filter Switch Bottom Drain Connection CPC Controller with Dirty Filter Switch & Air Proving Switch CPC Controller, DFS, APS & Phase Monitor CPC Controller, DFS, APS & Coil Guard CPC Controller, DFS, APS, Phase Monitor, & Coil Guard CPC Controller, DFS, APS & Technicoat Cond. Coil CPC Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor CPC Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard CPC Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard CPC Controller, DFS, APS & Technicoat Evap. Coil CPC Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor CPC Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard CPC Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard CPC Controller, DFS, APS & Technicoat Evap. & Cond Coils CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard CPC Controller, DFS, APS, SS Drain Pan CPC Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard CPC Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils CPC Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil CPC Controller, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils CPC Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Johnson UNT Controller with Dirty Filter Switch & Air Proving Switch Johnson UNT Controller, DFS, APS & Phase Monitor Johnson UNT Controller, DFS, APS & Coil Guard Johnson UNT Controller, DFS, APS, Phase Monitor, & Coil Guard Johnson UNT Controller, DFS, APS & Technicoat Cond. Coil Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard Johnson UNT Controller, DFS, APS & Technicoat Evap. Coil Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard Johnson UNT Controller, DFS, APS & Technicoat Evap. & Cond Coils Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor Unitary Products Group 5 036-21685-002-A-1105 Standard Cabinet JQ JR JS JT JU JV JW JX HA HB HC HD HE HF HG HH HJ HK HL HM HN HP HQ HR HS HT HU HV HW HX NA NB NC ND NE NF NG NH NJ NK NL NM NN NP NQ NR NS NT NU NV NW NX TA TB 6 Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard Johnson UNT Controller, DFS, APS, SS Drain Pan Johnson UNT Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils Johnson UNT Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Honeywell Excel 10 Controller with Dirty Filter Switch & Air Proving Switch Honeywell Excel 10 Controller, DFS, APS & Phase Monitor Honeywell Excel 10 Controller, DFS, APS & Coil Guard Honeywell Excel 10 Controller, DFS, APS, Phase Monitor, & Coil Guard Honeywell Excel 10 Controller, DFS, APS & Technicoat Cond. Coil Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. Coil Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. & Cond Coils Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils Honeywell Excel 10 Controller,DFS, APS, SS Drain Pan, & Technicoat Evap Coil Honeywell Excel 10 Controller,DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils Honeywell Excel 10 Controller,DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Novar ETC-3 Controller with Dirty Filter Switch & Air Proving Switch Novar ETC-3 Controller, DFS, APS & Phase Monitor Novar ETC-3 Controller, DFS, APS & Coil Guard Novar ETC-3 Controller, DFS, APS, Phase Monitor, & Coil Guard Novar ETC-3 Controller, DFS, APS & Technicoat Cond. Coil Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard Novar ETC-3 Controller, DFS, APS & Technicoat Evap. Coil Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard Novar ETC-3 Controller, DFS, APS & Technicoat Evap. & Cond Coils Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard Novar ETC-3 Controller, DFS, APS, SS Drain Pan Novar ETC-3 Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard Novar ETC-3 Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils Novar ETC-3 Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil Novar ETC-3, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils Novar ETC-3 Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Technicoat Condenser Coil Technicoat Condenser Coil & Phase Monitor Unitary Products Group 036-21685-002-A-1105 Standard Cabinet TC TD TE TF TG TH TJ TK TL TM TN TP TQ TR TS TT TU TV TW TX TY TZ T1 T3 T4 T6 T7 T9 LA LB LC LD LE LF LG LH LJ LK LL LM LN LP LQ LR LS LT LU LV LW LX WA WB WC WD Technicoat Condenser Coil & Coil Guard Technicoat Condenser Coil & Dirty Filter Switch Technicoat Condenser Coil, Phase Monitor, & Coil Guard Technicoat Condenser Coil, Phase Monitor, & Dirty Filter Switch Technicoat Condenser Coil, Coil Guard, & Dirty Filter Switch Technicoat Condenser Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch Technicoat Evaporator Coil Technicoat Evaporator Coil & Phase Monitor Technicoat Evaporator Coil & Coil Guard Technicoat Evaporator Coil & Dirty Filter Switch Technicoat Evaporator Coil, Phase Monitor, & Coil Guard Technicoat Evaporator Coil, Phase Monitor, & Dirty Filter Switch Technicoat Evaporator Coil, Coil Guard, & Dirty Filter Switch Technicoat Evaporator Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch Technicoat Evaporator & Condenser Coils Technicoat Evaporator & Condenser Coils & Phase Monitor Technicoat Evaporator & Condenser Coils & Coil Guard Technicoat Evaporator & Condenser Coils & Dirty Filter Switch Technicoat Evaporator & Condenser Coils, Phase Monitor, & Coil Guard Technicoat Evaporator & Condenser Coils, Phase Monitor, & Dirty Filter Switch Technicoat Evaporator & Condenser Coils, Coil Guard, & Dirty Filter Switch Technicoat Evaporator & Condenser Coils, Phase Monitor, Coil Guard, & Dirty Filter Switch Technicoat Condenser & SS Drain Pan Technicoat Condenser Coil, SS Drain Pan, Phase Monitor, Coil Guard, & Dirty Filter Switch Technicoat Evaporator & SS Drain Pan Technicoat Evaporator Coil, SS Drain Pan, Phase Monitor, Coil Guard, & Dirty Filter Switch Technicoat Evaporator & Condenser Coils & SS Drain Pan Technicoat Evaporator & Condenser Coils, SS Drain Pan, Phase Monitor, Coil Guard, & Dirty Filter Switch Simplicity Intelli-Comfort Controller Simplicity Intelli-Comfort Controller, & Phase Monitor Simplicity Intelli-Comfort Controller, & Coil Guard Simplicity Intelli-Comfort Controller, Phase Monitor, & Coil Guard Simplicity Intelli-Comfort Controller, & Technicoat Cond. Coil Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, & Phase Monitor Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, & Coil Guard Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, Phase Monitor, & Coil Guard Simplicity Intelli-Comfort Controller, & Technicoat Evap. Coil Simplicity Intelli-Comfort Controller, Technicoat Evap. Coil, & Phase Monitor Simplicity Intelli-Comfort Controller, Technicoat Evap. Coil, & Coil Guard Simplicity Intelli-Comfort Controller, Technicoat Evap. Coil, Phase Monitor, & Coil Guard Simplicity Intelli-Comfort Controller, & Technicoat Evap. & Cond Coils Simplicity Intelli-Comfort Controller, Technicoat Evap. & Cond Coils, & Phase Monitor Simplicity Intelli-Comfort Controller, Technicoat Evap. & Cond Coils, & Coil Guard Simplicity Intelli-Comfort Controller, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard Simplicity Intelli-Comfort Controller, SS Drain Pan Simplicity Intelli-Comfort Controller, SS Drain Pan, Phase Monitor, & Coil Guard Simplicity Intelli-Comfort Controller, SS Drain Pan, & Technicoat Cond Coils Simplicity Intelli-Comfort Controller, SS Drain Pan, & Technicoat Evap Coil Simplicity Intelli-Comfort Controller, SS Drain Pan, & Technicoat Evap and Cond Coils Simplicity Intelli-Comfort Controller, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Intelli-Comfort w/Mod Link Controller Intelli-Comfort w/Mod Link Controller, & Phase Monitor Intelli-Comfort w/Mod Link Controller, & Coil Guard Intelli-Comfort w/Mod Link Controller, Phase Monitor, & Coil Guard Unitary Products Group 7 036-21685-002-A-1105 Standard Cabinet WE WF WG WH WJ WK WL WM WN WP WQ WR WS WT WU WV WW WX Intelli-Comfort w/Mod Link Controller, & Technicoat Cond. Coil Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, & Phase Monitor Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, & Coil Guard Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, Phase Monitor, & Coil Guard Intelli-Comfort w/Mod Link Controller, & Technicoat Evap. Coil Intelli-Comfort w/Mod Link Controller, Technicoat Evap. Coil, & Phase Monitor Intelli-Comfort w/Mod Link Controller, Technicoat Evap. Coil, & Coil Guard Intelli-Comfort w/Mod Link Controller, Technicoat Evap. Coil, Phase Monitor, & Coil Guard Intelli-Comfort w/Mod Link Controller, & Technicoat Evap. & Cond Coils Intelli-Comfort w/Mod Link Controller, Technicoat Evap. & Cond Coils, & Phase Monitor Intelli-Comfort w/Mod Link Controller, Technicoat Evap. & Cond Coils, & Coil Guard Intelli-Comfort w/Mod Link Controller, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard Intelli-Comfort w/Mod Link Controller, SS Drain Pan Intelli-Comfort w/Mod Link Controller, SS Drain Pan, Phase Monitor, & Coil Guard Intelli-Comfort w/Mod Link Controller, SS Drain Pan, & Technicoat Cond Coils Intelli-Comfort w/Mod Link Controller, SS Drain Pan, & Technicoat Evap Coil Intelli-Comfort w/Mod Link Controller, SS Drain Pan, & Technicoat Evap and Cond Coils Intelli-Comfort w/Mod Link Controller, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Cabinet BA BB BC BD BE BF BG BH BJ BK BL BM BN BS DA DB DC DD DE DF DG DH DJ DK DL DM DN DP DQ DR DS DT DU DV 8 Hinged Filter Door & Toolless Access Panels Phase Monitor, Hinged Filter Door & Toolless Access Panels Coil Guard, Hinged Filter Door & Toolless Access Panels Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels Phase Monitor & Coil Guard, Hinged Filter Door & Toolless Access Panels Phase Monitor & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels Coil Guard & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels SS Drain Pan & Hinged Filter Door & Toolless Access Panels SS Drain Pan & Phase Monitor, Hinged Filter Door & Toolless Access Panels SS Drain Pan & Coil Guard, Hinged Filter Door & Toolless Access Panels SS Drain Pan & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels SS Drain Pan & Phase Monitor & Coil Guard, Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels Bottom Drain Connection, Hinged Filter Door & Toolless Access Panels CPC Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS & Technicoat Evap. Coil, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS & Technicoat Evap. & Cond Coils, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, SS Drain Pan Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil Hinged Filter Door & Toolless Access Panels Unitary Products Group 036-21685-002-A-1105 Hinged Filter Door & Toolless Access Cabinet DW CPC Controller, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels DX CPC Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels EA Johnson UNT Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Toolless Access Panels EB Johnson UNT Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Toolless Access Panels EC Johnson UNT Controller, DFS, APS & Coil Guard, Hinged Filter Door & Toolless Access Panels ED Johnson UNT Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels EE Johnson UNT Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels EF Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels EG Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels EH Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels EJ Johnson UNT Controller, DFS, APS & Technicoat Evap. Coil, Hinged Filter Door & Toolless Access Panels EK Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels EL Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels EM Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels EN Johnson UNT Controller, DFS, APS & Technicoat Evap. & Cond Coils, Hinged Filter Door & Toolless Access Panels EP Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Toolless Access Panels EQ Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Toolless Access Panels ER Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels ES Johnson UNT Controller, DFS, APS, SS Drain Pan Hinged Filter Door & Toolless Access Panels ET Johnson UNT Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard Hinged Filter Door & Toolless Access Panels EU Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils Hinged Filter Door & Toolless Access Panels EV Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil Hinged Filter Door & Toolless Access Panels EW Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels EX Johnson UNT Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels GA Honeywell Excel 10 Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Toolless Access Panels GB Honeywell Excel 10 Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Toolless Access Panels GC Honeywell Excel 10 Controller, DFS, APS & Coil Guard, Hinged Filter Door & Toolless Access Panels GD Honeywell Excel 10 Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels GE Honeywell Excel 10 Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels GF Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels GG Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels GH Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels GJ Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. Coil, Hinged Filter Door & Toolless Access Panels GK Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels GL Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels GM Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels GN Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. & Cond Coils, Hinged Filter Door & Toolless Access Panels GP Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Toolless Access Panels GQ Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Toolless Access Panels GR Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels GS Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan GT Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard GU Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils GV Honeywell Excel 10 Controller,DFS, APS, SS Drain Pan, & Technicoat Evap Coil GW Honeywell Excel 10 Controller,DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils GX Honeywell Excel 10 Controller,DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils PA Novar ETC-3 Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Toolless Access Panels Unitary Products Group 9 036-21685-002-A-1105 Hinged Filter Door & Toolless Access Cabinet PB PC PD PE PF PG PH PJ PK PL PM PN PP PQ PR Novar ETC-3 Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS & Technicoat Evap. Coil, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS & Technicoat Evap. & Cond Coils, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels PS Novar ETC-3 Controller, DFS, APS, SS Drain Pan PT Novar ETC-3 Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard PU Novar ETC-3 Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils PV Novar ETC-3 Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil PW Novar ETC-3, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils PX Novar ETC-3 Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils UA Technicoat Condenser Coil, Hinged Filter Door & Toolless Access Panels UB Technicoat Condenser Coil & Phase Monitor, Hinged Filter Door & Toolless Access Panels UC Technicoat Condenser Coil & Coil Guard, Hinged Filter Door & Toolless Access Panels UD Technicoat Condenser Coil & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UE Technicoat Condenser Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels UF Technicoat Condenser Coil, Phase Monitor, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UG Technicoat Condenser Coil, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UH Technicoat Condenser Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UJ Technicoat Evaporator Coil, Hinged Filter Door & Toolless Access Panels UK Technicoat Evaporator Coil & Phase Monitor, Hinged Filter Door & Toolless Access Panels UL Technicoat Evaporator Coil & Coil Guard, Hinged Filter Door & Toolless Access Panels UM Technicoat Evaporator Coil & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UN Technicoat Evaporator Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels UP Technicoat Evaporator Coil, Phase Monitor, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UQ Technicoat Evaporator Coil, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UR Technicoat Evaporator Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels US Technicoat Evaporator & Condenser Coils, Hinged Filter Door & Toolless Access Panels UT Technicoat Evaporator & Condenser Coils & Phase Monitor, Hinged Filter Door & Toolless Access Panels UU Technicoat Evaporator & Condenser Coils & Coil Guard, Hinged Filter Door & Toolless Access Panels UV Technicoat Evaporator & Condenser Coils & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UW Technicoat Evaporator & Condenser Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels UX Technicoat Evaporator & Condenser Coils, Phase Monitor, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UY Technicoat Evaporator & Condenser Coils, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UZ Technicoat Evaporator & Condenser Coils, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels U1 Technicoat Condenser & SS Drain Pan, Hinged Filter Door & Toolless Access Panels U3 Technicoat Condenser Coil, SS Drain Pan, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels U4 Technicoat Evaporator & SS Drain Pan, Hinged Filter Door & Toolless Access Panels U6 Technicoat Evaporator Coil, SS Drain Pan, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels U7 Technicoat Evaporator & Condenser Coils & SS Drain Pan, Hinged Filter Door & Toolless Access Panels U9 Technicoat Evaporator & Condenser Coils, SS Drain Pan, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels QA Simplicity Intelli-Comfort Controller with Hinged Filter Door & Toolless Access Panels QB Simplicity Intelli-Comfort Controller, & Phase Monitor, Hinged Filter Door & Toolless Access Panels 10 Unitary Products Group 036-21685-002-A-1105 Hinged Filter Door & Toolless Access Cabinet QC QD QE QF QG QH QJ QK QL QM QN QP QQ QR QS QT QU QV QW QX Simplicity Intelli-Comfort Controller, & Coil Guard, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Simplicity Intelli-Comfort Controller, & Technicoat Evap. Coil, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Simplicity Intelli-Comfort Controller, & Technicoat Evap. & Cond Coils, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Toolless Access Pan Simplicity Intelli-Comfort Controller, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolles Simplicity Intelli-Comfort Controller, SS Drain Pan Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, SS Drain Pan, Phase Monitor, & Coil Guard Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, SS Drain Pan, & Technicoat Cond Coils Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, SS Drain Pan, & Technicoat Evap Coil Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, SS Drain Pan, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels XA Intelli-Comfort w/Mod Link Controller, Hinged Filter Door & Toolless Access Panels XB Intelli-Comfort w/Mod Link Controller, & Phase Monitor, Hinged Filter Door & Toolless Access Panels XC Intelli-Comfort w/Mod Link Controller, & Coil Guard, Hinged Filter Door & Toolless Access Panels XD Intelli-Comfort w/Mod Link Controller, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels XE Intelli-Comfort w/Mod Link Controller, & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels XF Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels XG Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels XH Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access XJ Intelli-Comfort w/Mod Link Controller, & Technicoat Evap. Coil, Hinged Filter Door & Toolless Access Panels XK Intelli-Comfort w/Mod Link Controller, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels XL Intelli-Comfort w/Mod Link Controller, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels XM Intelli-Comfort w/Mod Link Controller, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access XN Intelli-Comfort w/Mod Link Controller, & Technicoat Evap. & Cond Coils, Hinged Filter Door & Toolless Access Panels XP Intelli-Comfort w/Mod Link Controller, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Toolless Access Pan XQ Intelli-Comfort w/Mod Link Controller, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Toolless Access Panels XR Intelli-Comfort w/Mod Link Controller, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolles XS Intelli-Comfort w/Mod Link Controller, SS Drain Pan Hinged Filter Door & Toolless Access Panels XT Intelli-Comfort w/Mod Link Controller, SS Drain Pan, Phase Monitor, & Coil Guard Hinged Filter Door & Toolless Access Panels XU Intelli-Comfort w/Mod Link Controller, SS Drain Pan, & Technicoat Cond Coils Hinged Filter Door & Toolless Access Panels XV Intelli-Comfort w/Mod Link Controller, SS Drain Pan, & Technicoat Evap Coil Hinged Filter Door & Toolless Access Panels XW Intelli-Comfort w/Mod Link Controller, SS Drain Pan, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels XX Intelli-Comfort w/Mod Link Controller, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels Unitary Products Group 11 036-21685-002-A-1105 FEATURES gas valve, if applicable, and the temperature limit switch on gas heat units. The unit control board will alarm on ignition failures, compressor lockouts and repeated limit switch trips. All models are available with a wide variety of factorymounted options such as stainless steel heat exchangers, electric heaters, phase monitor, convenience outlet, dirty filter switch, disconnect switch, smoke detectors, and coil guard to make them suitable for almost every application. All units are self-contained and assembled on full perimeter base rails with forklift holes on three sides and holes for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to simplify the field installation and to provide years of dependable operation. All models (including those with an economizer) are suitable for either bottom or horizontal duct connections. For bottom duct, remove the sheet metal panels from the supply and return air openings through the base of the unit. For horizontal duct, remove the supply and return air panels on the rear of the unit. All models are available with these “factory mounted” outdoor air damper options: • Single enthalpy economizer • Motorized outdoor air damper • • Anti-Short Cycle Protection - To aid compressor life, an anti-short cycle delay is incorporated into the standard controls. Compressor reliability is further ensured by programmable minimum run times. For testing, the anti short cycle delay can be temporarily overridden with the push of a button. • Fan Delays - Fan on and fan off delays are fully programmable and are independent of one another. All units are programmed with default values based upon their configuration of cooling and heat. • 12 Low Ambient - An integrated low-ambient control allows all units to operate in the cooling mode down to 0ºF outdoor ambient without additional assistance. Optionally, the control board can be programmed to lockout the compressors when the outdoor air temperature is low or when free cooling is available. Safety Monitoring - The control board monitors the high and low-pressure switches, the freezestats, the • On Board Diagnostics - Each alarm will energize a trouble light on the thermostat, if so equipped, and flash an alarm code on the control board LED. Each high and low-pressure switch alarm as well as each freezestat alarm has its own flash code. The control board saves the five most recent alarms in memory, and these alarms can be reviewed at any time. Alarms and programmed values are retained through the loss of power. All models are CSA listed. • Warranty - All models include a one-year limited parts warranty on the complete unit. Compressors and electric heater elements carry a five-year warranty. Gas heat exchangers carry a 10-year parts warranty. • Gas Heat Operation - All single phase models with gas heat have minimum annual fuel utilization efficiency (AFUE) of 80%. All three phase models with gas heat have minimum steady state efficiency of 80%. Each section includes a durable heat exchanger with aluminized steel or optional stainless steel tubes, a redundant gas valve, spark ignition, power venting, an ignition module for 100% shut-off and all of the safety controls required to meet the latest ANSI standards. Simplicity™ Controls - Simplicity™ control boards have standardized a number of features previously available only as options or by utilizing additional controls. • Nuisance Trip Protection- To prevent nuisance trouble calls, the control board uses a “three strikes, you’re out” philosophy. The high and low-pressure switches and the freezestats must trip three times within two hours before the unit control board will lock out the compressor. All units have long lasting powder paint cabinets with 1000 hour salt spray test approval under ASTM-B117 procedures. Supply air blowers are equipped with a belt drive that can be adjusted to meet the exact requirements of the job. All compressors are equipped with internal pressure relief. Every refrigerant circuit includes a liquid line filter-drier, a high pressure switch and a suction line with a freezestat and low pressure/loss of charge switch to protect all system components. • The gas supply piping can be routed into the heating compartment through a hole in the base pan of the unit or through a knockout in the piping panel on the front of the unit. • Electric Heat Operation - All electric heat models are wired for a single power source and include a bank of nickel chromium elements mounted at the discharge of the supply air blower to provide a high velocity and uniform distribution of air across the heating elements. Every element is fully protected against excessive temperature by thermal limit switches. The power supply wiring can be routed into the control box through a threaded pipe connection (field supplied) in the base pan of the unit or through a knockout in the wiring panel on the side of the unit. • BAS Controls - York’s Sunline™ series units offer factory mounted BAS controls such as SImplicity™ INTELLIComfort™, Novar, Honeywell, Johnson, and CPC. Unitary Products Group 036-21685-002-A-1105 FIGURE 1 - UNIT CUTAWAY FACTORY-INSTALLED OPTIONS • SINGLE INPUT ELECTRONIC ENTHALPY ECONOMIZERS - Includes a slide-in / plug-in damper assembly with fully modulating spring-return motor actuator capable of introducing up to 100% outdoor air with nominal 1% leakage type dampers. The enthalpy system contains one sensor that monitors the outdoor air and determines when the air is cool enough and dry enough to provide free cooling. The rainhood is painted to match the basic unit and must be field-assembled before installing. • MOTORIZED OUTDOOR AIR INTAKE DAMPER Includes a slide-in / plug-in damper assembly with a 2position, spring return motor actuator which opens to a pre-set position whenever the supply air blower is operating and will drive fully closed when the blower unit shuts down. The rain hood is painted to match the basic unit and must be field assembled before installing. • PHENOLIC COATED EVAPORATOR AND CONDENSER COILS - Special coating process that utilizes Technicoat 10-1TM processes. Coating is applied by total immersion of the complete coil for maximum protection. Unitary Products Group • ELECTRIC HEATERS - Wired for single point power supply. These nickel chromium heater elements are provided with limit and automatic reset capability to prevent operation at excessive temperatures. • FILTER OPTIONS - Standard units are shipped with 1” throw-away filters installed. 2” pleated filters are offered as a factory installed option. • CONVENIENCE OUTLET - This 110 volt outlet can be “powered” by the unit with a stepdown transformer or the unit may be ordered with a “non-powered” convenience outlet that can be wired in the field. • DISCONNECT SWITCH - For gas heat units and cooling units with electric heat, a HACR breaker sized to the unit is provided. For cooling only units, a switch sized to the largest electric heat available for the particular unit is provided. Factory installed option only. • BAS - Building Automation System Controls Simplicity™ INTELLI-Comfort™ CONTROL - The York® Simplicity™ INTELLI-Comfort™ control is factory installed. It includes a supply air sensor, a return air sensor, and an outside air sensor. There are provisions for a field installed dirty filter indicator switch, an air-proving switch, an Outside Air Humidity sensor, a Return Air Humidity sensor, an Inside IAQ sensor, and an Outside Air IAQ sensor. Construction mode operation, 365-day real time clock with 7 day programming plus holiday 13 036-21685-002-A-1105 scheduling is built-in. Two different modes of demand ventilation are achieved through the INTELLI-Comfort™using CO2 sensors. It uses an inside CO2 sensor to perform Demand Ventilation. It can also use an Outside CO2 sensor to perform Differential Demand Ventilation. It uses a Patented Comfort Ventilation algorithm to provide comfortable ventilation air temperature. The patented economizer-loading algorithm will protect the equipment when harsh operating conditions exist. Humidity in the occupied space or return duct can be monitored and controlled via humidity sensors and the on-board connection for hot gas re-heat system. It uses the INTELLI-Start™ algorithm to maximize energy savings by recovering the building from the Unoccupied Setpoints to the Occupied Setpoints just in time for the Occupied Time Period to begin. The Simplicity™ INTELLI-Comfort™ balances space temperature, ventilation air temperature, CO2 and humidity for ultimate comfort. • Simplicity™ INTELLI-Comfort™ with MOD LINK CONTROL - The York® Simplicity™ INTELLI-Comfort™ with Mod Link control is factory installed. It includes all the features of the INTELLI-Comfort™ control with an additional control to translate communications from MODBUS to the BACnet MSTP protocol. • Novar® BAS CONTROL - The Novar® ETC-3 building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch, and air proving switch. • JOHNSON CONTROLS BAS CONTROL - The Johnson Control YK-UNT-1126 building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch, and air proving switch. • • STAINLESS STEEL HEAT EXCHANGER - For applications in corrosive environments, this option provides a full stainless steel heat exchanger assembly. • STAINLESS STEEL DRAIN PAN - An optional rustproof stainless steel drain pan is available to provide years of trouble-free operation in corrosive environments. • BOTTOM DRAIN CONNECTION - An optional bottom drain connection is available for inside the curb connections for applications in cold environments to reduce freezing drain lines. • PHASE MONITORS - Designed to prevent unit damage. The phase monitor will shut the unit down in an out-ofphase condition. • DIRTY FILTER SWITCH - This kit includes a differential pressure switch that energizes the fault light on the unit thermostat, indicating that there is an abnormally high pressure drop across the filters. Factory installed option or field installed accessory. • HINGED FILTER DOOR/“TOOLLESS” BLOWER AND ACCESS PANELS (not hinged) - This option allows for easy access and maintenance. NOTE:Knobs are shipped inside the unit to prevent shipping damage. These must be field installed for tool-less operation. FIELD-INSTALLED ACCESSORIES • CPC BAS CONTROL - The Computer Process Controls Model 810-3060 ARTC Advanced Rooftop building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch and air proving switch. HONEYWELL BAS CONTROL - The Honeywell W7750C building automation system controller is factory installed. Includes air supply sensor, return air sensor, dirty filter indicator switch, and air proving switch. • SMOKE DETECTORS - (supply air & return air) The smoke detectors stop operation of the unit by interrupting power to the control board if smoke is detected within the air compartment. • COIL GUARD - Customers can purchase a coil guard kit to protect the condenser coil from damage. This is not a hail guard kit. 14 • SINGLE INPUT ELECTRONIC ENTHALPY ECONOMIZERS - Includes a slide-in / plug-in damper assembly with fully modulating spring-return motor actuator capable of introducing up to 100% outdoor air with nominal 1% leakage type dampers. The enthalpy system contains one sensor that monitors the outdoor air and determines when the air is cool enough and dry enough to provide free cooling. The rainhood is painted to match the basic unit and must be field-assembled before installing. • MOTORIZED OUTDOOR AIR INTAKE DAMPER Includes a slide-in / plug-in damper assembly with a 2position, spring return motor actuator which opens to some pre-set position whenever the supply air blower is operating and will drive fully closed when the blower unit shuts down. The rain hood is painted to match the basic unit and must be field assembled before installing. • ELECTRIC HEATERS wired for single point power supply. These nickel chromium heater elements are provided with limit and automatic reset capability to prevent operation at excessive temperatures. Unitary Products Group 036-21685-002-A-1105 • ROOF CURBS - Eight and fourteen-inch high roof curbs provide a water-tight seal between the unit and the finished roof. These full perimeter curbs meet the requirements of the National Roofing Contractors Association (NRCA) and are shipped knocked-down for field assembly. Roof curbs are designed to fit inside the base rails of the unit and include both a wood nailing strip and duct hanger supports. • HIGH ALTITUDE NATURAL GAS - Burner orifices and pilot orifices are provided for proper furnace operation at altitudes up to 6,000 feet. • PROPANE - Burner orifices, pilot orifices and gas valve parts are provided to convert a natural gas furnace to propane. • HIGH ALTITUDE PROPANE - Burner orifices and pilot orifices are provided for proper furnace operation at altitudes up to 6,000 feet. This accessory supplements the basic propane conversion kit. • LOW NOX KIT- Required to reduce the emission of nitrogen oxides below 40 nanograms per joule. • POWER EXHAUST - Our single input economizer options are available with power exhaust. Whenever the outdoor air intake dampers are opened for free cooling, the exhaust fan will be energized to prevent the conditioned space from being over-pressurized during economizer operation. • FLUE EXHAUST EXTENSION KIT - In locations with wind or weather conditions which may interfere with proper exhausting of furnace combustion products, this kit can be installed to prevent the flue exhaust from entering nearby fresh air intakes. • CO2 SENSOR - Senses CO2 levels and automatically overrides the economizer when levels rise above the present limits. • COIL GUARD - Customers can purchase a coil guard kit to protect the condenser coil from damage. This is not a hail guard kit. • HAIL GUARD - Hail guard kit is available to prevent unit from hail damage. This is a sloped hood that fits above the coil. • GAS PIPING KIT - This kit supplies all necessary fittings and shut off valve. REHEAT MODE SEQUENCE OF OPERATION • STANDARD A/C MODE: INPUT: Y1 ON, Y2 OFF, HUMIDISTAT OPEN - During normal cooling operation, a Y1 call from the thermostat will bring on the unit in the standard cooling mode. Since the humidistat is open, the liquid line solenoid (SLL) will be open and the hot gas solenoid (SHG) will be closed allowing the unit to operate in the standard cooling mode. • REHEAT MODE: INPUT: Y1 ON, Y2 OFF, HUMIDISTAT CLOSED - During reheat mode, the Y1 signal will bring on the compressor and will send the 24V signal through the humidistat, through the normally closed contacts of the hot gas relay (RHG) and will energize both the liquid line and the hot gas solenoids which directs hot gas through part of the indoor coil and decreases the sensible capacity of the unit. • STANDARD A/C MODE: INPUT: Y1 ON, Y2 ON, HUMIDISTAT OPEN OR CLOSED - If there is a call for Y1 and Y2, the unit will be in normal cooling mode regardless of the humidistat input. The Y2 signal will energize the hot gas relay (RHG) which will keep the liquid line solenoid (SLL) open and the hot gas solenoid (SHG) closed and the unit will operate in the normal cooling mode. The power exhaust option can only be used on bottom duct configurations. • BAROMETRIC RELIEF DAMPER - This damper accessory can be used to relieve internal building air pressure on units with an economizer without power exhaust. This accessory includes a rain hood, a bird screen and a fully assembled damper. With bottom duct connections, the damper should be mounted over the opening in the return air panel. With horizontal ductwork, the accessory should be mounted on the return air duct. • ENTHALPY ACCESSORY CONTROL KIT - This kit contains the required components to convert a single enthalpy economizer to dual enthalpy. • BURGLAR BARS - Mount in the supply and return openings to prevent entry into the duct work. Unitary Products Group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±,'EORZHUFRPSUHVVRUDQGRXWGRRUIDQRSHUDWLQJ 7HVW'XFW'LPHQVLRQLQZLGH[LQKLJK[IWORQJP[P[P 7HVWGXFWWHUPLQDWLRQLVIOXVKZLWKUHYHUEHUDWLRQURRPZDOO 'XFWHQGVRXQGUHIOHFWLRQFRUUHFWLRQG%DWNNN+] TABLE 2: DR036 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED DISCHARGE) UNIT DESCRIPTION / MODEL CONFIGURATION Indoor Blower Speed (RPM) Blower Static Pressure (IWG) Airflow (CFM) Blower Motor BHP Octave Center Freq. 63 125 250 500 1000 2000 4000 8000 630 0.2 1116 0.41 Cooling ID Blower Operation2 Only (dB) (dB) 80 84 74 77 58 61 48 51 41 45 39 41 41 41 45 45 DR036 / 3 Ton / Belt Drive Horizontal Ducted Discharge 631 879 885 0.3 0.2 0.7 928 1979 1020 0.37 0.76 0.53 Cooling Cooling Cooling ID Blower ID Blower ID Blower Operation2 Operation2 Operation2 Only (dB) Only (dB) Only (dB) (dB) (dB) (dB) 80 83 85 87 84 87 74 76 80 82 80 83 58 61 68 68 63 65 47 50 58 58 53 54 39 43 55 55 49 50 37 39 53 53 46 47 38 38 55 55 49 49 44 44 52 53 47 47 1. Tested in accordance with ARI Standard 260. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment . 2. Cooling Operation – ID blower, compressor and outdoor fan operating. 3. Test Duct Dimension: 12 in. wide x 18 in. high x 8 ft. long (0.30m x 0.46m x 2.44m). 4. Test duct termination is flush with reverberation room wall. 5. Duct end (sound reflection) correction: (11, 6, 3, 1, 0, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 4k, 8k) Hz. 16 Unitary Products Group 036-21685-002-A-1105 TABLE 3: DR036 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED INLET) UNIT DESCRIPTION / MODEL CONFIGURATION Indoor Blower Speed (RPM) Blower Static Pressure (IWG) Airflow (CFM) Blower Motor BHP Octave Center Freq. 63 125 250 500 1000 2000 4000 8000 632 0.2 1069 0.36 Cooling ID Blower Operation2 Only (dB) (dB) 78 82 70 75 55 60 47 50 40 43 37 40 36 37 44 44 DR036 / 3 Ton / Belt Drive Vertical Ducted Inlet 632 881 883 0.3 0.2 0.7 870 1903 917 0.33 0.71 0.49 Cooling Cooling Cooling ID Blower ID Blower ID Blower Operation2 Operation2 Operation2 Only (dB) Only (dB) Only (dB) (dB) (dB) (dB) 78 82 80 85 80 84 70 74 71 80 71 79 55 60 59 61 58 62 47 50 52 53 49 52 39 43 50 51 45 46 37 39 45 46 41 43 36 37 45 46 40 40 44 44 45 47 44 44 1. Tested in accordance with ARI Standard 260. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment . 2. Cooling Operation – ID blower, compressor and outdoor fan operating. 3. Test Duct Dimension: 12 in. wide x 18 in. high x 8 ft. long (0.30m x 0.46m x 2.44m). 4. Test duct termination is flush with reverberation room wall. 5. Duct end (sound reflection) correction: (11, 6, 3, 1, 0, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 4k, 8k) Hz. TABLE 4: DR036 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED DISCHARGE) UNIT DESCRIPTION / MODEL CONFIGURATION Indoor Blower Speed (RPM) Blower Static Pressure (IWG) Airflow (CFM) Blower Motor BHP Octave Center Freq. 63 125 250 500 1000 2000 4000 8000 632 0.2 1069 0.36 Cooling ID Blower Operation2 Only (dB) (dB) 80 83 78 79 55 60 48 51 41 44 37 40 38 39 44 45 DR036 / 3 Ton / Belt Drive Vertical Ducted Discharge 632 881 883 0.3 0.2 0.7 870 1903 917 0.33 0.71 0.49 Cooling Cooling Cooling ID Blower ID Blower ID Blower Operation2 Operation2 Operation2 Only (dB) Only (dB) Only (dB) (dB) (dB) (dB) 80 83 83 86 82 85 77 78 80 83 79 82 54 59 63 63 58 62 46 50 58 59 52 53 39 43 54 55 48 49 35 38 50 50 42 44 36 37 52 53 44 44 44 44 49 50 45 45 1. Tested in accordance with ARI Standard 260. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment . 2. Cooling Operation – ID blower, compressor and outdoor fan operating. 3. Test Duct Dimension: 12 in. wide x 18 in. high x 8 ft. long (0.30m x 0.46m x 2.44m). 4. Test duct termination is flush with reverberation room wall. 5. Duct end (sound reflection) correction: (11, 6, 3, 1, 0, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 4k, 8k) Hz. Unitary Products Group 17 036-21685-002-A-1105 TABLE 5: DR048 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED INLET) UNIT DESCRIPTION / MODEL CONFIGURATION Indoor Blower Speed (RPM) Blower Static Pressure (IWG) Airflow (CFM) Blower Motor BHP Octave Center Freq. 63 125 250 500 1000 2000 4000 8000 766 0.2 1484 0.67 Cooling ID Blower Operation2 Only (dB) (dB) 74 97 70 86 53 58 49 55 42 42 40 44 38 44 42 43 DR048 / 4 Ton / Belt Drive Horizontal Ducted Inlet 769 1077 1087 0.5 0.4 1.0 993 2270 1406 1.24 0.90 0.54 Cooling Cooling Cooling ID Blower ID Blower ID Blower Operation2 Operation2 Operation2 Only (dB) Only (dB) Only (dB) (dB) (dB) (dB) 74 95 77 90 77 90 69 86 73 78 72 77 52 57 60 61 58 61 47 54 54 56 51 53 38 39 50 55 45 45 38 43 48 51 45 46 36 41 48 52 43 45 42 44 45 48 44 45 1. Tested in accordance with ARI Standard 260. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment . 2. Cooling Operation – ID blower, compressor and outdoor fan operating. 3. Test Duct Dimension: 12 in. wide x 18 in. high x 8 ft. long (0.30m x 0.46m x 2.44m). 4. Test duct termination is flush with reverberation room wall. 5. Duct end (sound reflection) correction: (11, 6, 3, 1, 0, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 4k, 8k) Hz. TABLE 6: DR048 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED DISCHARGE) UNIT DESCRIPTION / MODEL CONFIGURATION Indoor Blower Speed (RPM) Blower Static Pressure (IWG) Airflow (CFM) Blower Motor BHP Octave Center Freq. 63 125 250 500 1000 2000 4000 8000 766 0.2 1484 0.67 Cooling ID Blower Operation2 Only (dB) (dB) 77 97 72 86 60 62 53 56 47 47 45 46 46 47 47 47 DR048 / 4 Ton / Belt Drive Horizontal Ducted Discharge 769 1077 1087 0.5 0.4 1.0 993 2270 1406 0.54 1.24 0.90 Cooling Cooling Cooling ID Blower ID Blower ID Blower Operation2 Operation2 Operation2 Only (dB) Only (dB) Only (dB) (dB) (dB) (dB) 75 95 84 91 82 91 69 85 81 83 78 80 57 59 71 71 66 67 49 54 60 61 55 56 42 43 58 59 52 52 40 43 54 55 50 50 40 42 57 58 52 52 45 45 54 54 48 49 1. Tested in accordance with ARI Standard 260. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment . 2. Cooling Operation – ID blower, compressor and outdoor fan operating. 3. Test Duct Dimension: 12 in. wide x 18 in. high x 8 ft. long (0.30m x 0.46m x 2.44m). 4. Test duct termination is flush with reverberation room wall. 5. Duct end (sound reflection) correction: (11, 6, 3, 1, 0, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 4k, 8k) Hz. 18 Unitary Products Group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±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±,'EORZHUFRPSUHVVRUDQGRXWGRRUIDQRSHUDWLQJ 7HVW'XFW'LPHQVLRQLQZLGH[LQKLJK[IWORQJP[P[P 7HVWGXFWWHUPLQDWLRQLVIOXVKZLWKUHYHUEHUDWLRQURRPZDOO 'XFWHQGVRXQGUHIOHFWLRQFRUUHFWLRQG%DWNNN+] Unitary Products Group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±,'EORZHUFRPSUHVVRUDQGRXWGRRUIDQRSHUDWLQJ 7HVW'XFW'LPHQVLRQLQZLGH[LQKLJK[IWORQJP[P[P 7HVWGXFWWHUPLQDWLRQLVIOXVKZLWKUHYHUEHUDWLRQURRPZDOO 'XFWHQGVRXQGUHIOHFWLRQFRUUHFWLRQG%DWNNN+] TABLE 10: DR060 & 072 INDOOR SOUND POWER LEVELS (HORIZONTAL DUCTED DISCHARGE) UNIT DESCRIPTION / MODEL CONFIGURATION Indoor Blower Speed (RPM) Blower Static Pressure (IWG) Airflow (CFM) Blower Motor BHP Octave Center Freq. 63 125 250 500 1000 2000 4000 8000 840 0.2 1695 0.67 Cooling ID Blower Operation2 Only (dB) (dB) 82 87 75 76 69 69 64 64 59 60 55 55 58 58 55 55 DR060 & 072 / 5 & 6 Ton / Belt Drive Horizontal Ducted Discharge 845 1166 1188 0.3 1.3 0.6 2618 1323 1100 0.80 0.50 1.51 Cooling Cooling Cooling ID Blower ID Blower ID Blower Operation2 Operation2 Operation2 Only (dB) Only (dB) Only (dB) (dB) (dB) (dB) 79 88 88 89 82 87 72 74 82 83 78 78 66 66 79 79 73 73 60 60 72 72 66 66 55 56 68 68 61 61 50 50 65 65 57 57 52 52 68 68 60 60 49 49 66 67 56 56 1. Tested in accordance with ARI Standard 260. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment . 2. Cooling Operation – ID blower, compressor and outdoor fan operating. 3. Test Duct Dimension: 12 in. wide x 18 in. high x 8 ft. long (0.30m x 0.46m x 2.44m). 4. Test duct termination is flush with reverberation room wall. 5. Duct end (sound reflection) correction: (11, 6, 3, 1, 0, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 4k, 8k) Hz. 20 Unitary Products Group 036-21685-002-A-1105 TABLE 11: DR060 & 072 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED INLET) UNIT DESCRIPTION / MODEL CONFIGURATION Indoor Blower Speed (RPM) Blower Static Pressure (IWG) Airflow (CFM) Blower Motor BHP Octave Center Freq. 63 125 250 500 1000 2000 4000 8000 834 0.2 1525 0.61 Cooling ID Blower Operation2 Only (dB) (dB) 77 86 69 70 56 63 50 52 48 51 43 47 47 49 46 47 DR060 & 072 / 5 & 6 Ton / Belt Drive Vertical Ducted Inlet 840 1171 1194 0.6 0.2 1.3 1019 2624 1256 0.44 1.43 0.83 Cooling Cooling Cooling ID Blower ID Blower ID Blower Operation2 Operation2 Operation2 Only (dB) Only (dB) Only (dB) (dB) (dB) (dB) 79 88 81 86 83 87 70 72 71 73 72 72 56 58 64 72 63 69 48 49 57 59 53 56 44 45 57 58 49 52 39 41 54 57 47 50 40 41 55 61 47 52 44 45 51 57 47 49 1. Tested in accordance with ARI Standard 260. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment . 2. Cooling Operation – ID blower, compressor and outdoor fan operating. 3. Test Duct Dimension: 12 in. wide x 18 in. high x 8 ft. long (0.30m x 0.46m x 2.44m). 4. Test duct termination is flush with reverberation room wall. 5. Duct end (sound reflection) correction: (11, 6, 3, 1, 0, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 4k, 8k) Hz. TABLE 12: DR060 & 072 INDOOR SOUND POWER LEVELS (VERTICAL DUCTED DISCHARGE) UNIT DESCRIPTION / MODEL CONFIGURATION Indoor Blower Speed (RPM) Blower Static Pressure (IWG) Airflow (CFM) Blower Motor BHP Octave Center Freq. 63 125 250 500 1000 2000 4000 8000 834 0.2 1525 0.61 Cooling ID Blower Operation2 Only (dB) (dB) 83 88 78 78 66 67 59 60 57 58 51 52 54 54 52 52 DR060 & 072 / 5 & 6 Ton / Belt Drive Vertical Ducted Discharge 840 1171 1194 0.6 0.2 1.3 1019 2624 1256 0.44 1.43 0.83 Cooling Cooling Cooling ID Blower ID Blower ID Blower Operation2 Operation2 Operation2 Only (dB) Only (dB) Only (dB) (dB) (dB) (dB) 82 88 91 91 85 88 75 76 85 85 79 79 62 62 77 78 70 72 54 54 70 70 61 61 51 51 68 68 57 58 45 45 62 63 52 53 47 47 65 66 55 56 46 47 65 66 52 53 1. Tested in accordance with ARI Standard 260. Refer to 2001 Standard for Sound Rating of Ducted Air Moving and Conditioning Equipment . 2. Cooling Operation – ID blower, compressor and outdoor fan operating. 3. Test Duct Dimension: 12 in. wide x 18 in. high x 8 ft. long (0.30m x 0.46m x 2.44m). 4. Test duct termination is flush with reverberation room wall. 5. Duct end (sound reflection) correction: (11, 6, 3, 1, 0, 0, 0, 0) dB at (63, 125, 250, 500, 1k, 4k, 8k) Hz. Unitary Products Group 21 036-21685-002-A-1105 TABLE 14: GAS HEAT RATINGS1 TABLE 13: CAPACITY RATINGS UNIT SIZE (MBH) COOLING PERFORMANCE SOUND RATING3 SEER4 EER5 DECIBELS DR036 36.0 1 13.01 11.5 84 DR048 45.51 13.01 11.5 83 DR060 56.5 1 1 13.0 11.5 81 DR072 70.02 - 10.42 84 MBH 1. Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240. 2. Certified in accordance with the Unitary Large Equipment certification program, which is based on ARI Standard 340/360. 3. Rated in accordance with ARI Standard 270. 4. SEER = Seasonal Energy Efficiency Ratio - the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. 5. EER = Energy Efficiency Ratio - the cooling capacity in BTU’s per hour (BTUH) divided by the power input in watts at any given set of rating conditions, expressed in BTUH per watt (BTUH/watt). MODEL MBH INPUT MBH OUTPUT AFUE (%) TEMP RISE ºF DR036N04 DR036N08 50 100 40 80 80.9 80.5 15 - 45 40 - 70 DR048N06 DR048N10 75 125 60 100 80.9 80.3 25 - 55 45 - 75 DR060N08 DR060N10 100 125 80 100 80.5 80.3 25 - 55 35 - 65 DR072N08 DR072N10 100 125 80 100 80.5 80.3 25 - 55 35 - 65 1. All units are single-stage heating. TABLE 15: 2 STAGE GAS HEAT RATINGS MODEL1 MBH INPUT MBH OUTPUT 1ST STAGE 2ND STAGE 1ST STAGE 2ND STAGE STEADY STATE EFFICIENCY RISE 1ST STAGE 2ND STAGE MIN. MAX. MINIMUM HEATING AIRFLOW (CFM) 790 DR036D06 45 75 35.8 60.8 79.4 81.1 35 70 DR036D10 69 115 55.2 92 80.0 80.2 55 90 950 DR048D06 45 75 35.7 60.8 79.4 81.1 25 70 790 DR048D10 75 125 60.4 100.6 80.5 80.5 45 75 1230 DR060D06 45 75 35.8 60.8 79.4 81.1 35 70 1010 DR060D10 75 125 60.4 100.6 80.5 80.5 45 75 1230 DR072D06 45 75 35.8 60.8 79.4 81.1 35 70 1230 DR072D10 75 125 60.4 100.6 80.5 80.5 45 75 1230 1. Models are 3Ø only. 22 Unitary Products Group 036-21685-002-A-1105 TABLE 16: DR036 COOLING CAPACITIES (3 TON) - NORMAL MODE Temperature of Air on Condenser Coil Air on Evaporator Coil 75°F CFM 900 1050 1200 1350 1500 900 1050 1200 1350 1500 900 1050 1200 1350 1500 WB (°F) Total Total Cap.1 Input (MBH) (kW) 85°F * 2 Sensible Capacity (MBH) Return Dry Bulb (°F) 86 83 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 49.0 43.1 38.1 37.2 51.1 44.9 39.7 38.7 53.2 46.8 41.4 40.3 54.4 47.8 42.3 41.2 55.6 48.9 43.2 42.1 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.4 2.4 2.3 2.3 2.4 2.4 2.4 2.4 24.5 29.7 35.5 37.2 26.9 32.6 38.4 38.7 29.4 35.6 41.4 40.3 31.5 38.1 42.3 41.2 33.6 40.6 43.2 42.1 22.4 27.6 33.1 37.2 24.5 30.2 36.9 38.7 26.7 32.9 40.7 40.3 28.5 35.1 41.9 41.2 30.3 37.3 43.2 42.1 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 40.1 35.9 31.3 30.8 41.5 37.1 32.3 31.8 42.8 38.3 33.4 32.9 43.2 38.6 33.7 33.2 43.6 39.0 33.9 33.4 2.8 2.8 2.7 2.7 2.8 2.8 2.7 2.7 2.8 2.8 2.8 2.7 2.8 2.8 2.8 2.7 2.8 2.8 2.8 2.7 21.0 26.4 31.3 30.8 22.9 28.8 32.3 31.8 24.9 31.2 33.4 32.9 26.7 33.4 33.7 33.2 28.6 35.6 33.9 33.4 18.9 24.3 29.5 30.8 20.6 26.4 31.4 31.8 22.3 28.5 33.4 32.9 23.8 30.5 33.7 33.2 25.4 32.5 33.9 33.4 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 32.9 28.4 25.4 24.2 33.3 28.7 25.7 24.5 33.6 29.0 25.9 24.8 33.6 29.0 25.9 24.7 33.5 28.9 25.8 24.7 3.2 3.2 3.1 3.1 3.3 3.2 3.1 3.1 3.3 3.2 3.2 3.1 3.3 3.2 3.2 3.1 3.3 3.2 3.2 3.2 16.8 22.0 25.4 24.2 18.4 24.1 25.7 24.5 20.1 26.2 25.9 24.8 21.6 27.5 25.9 24.7 23.0 28.9 25.8 24.7 14.8 20.0 25.4 24.2 16.2 21.8 25.6 24.5 17.6 23.6 25.9 24.8 18.8 25.3 25.9 24.7 20.1 27.0 25.8 24.7 80 20.3 25.5 31.0 34.5 22.1 27.8 33.9 37.6 24.0 30.2 36.7 40.8 25.5 32.1 39.9 41.5 27.0 34.0 43.2 42.1 95°F 16.8 22.2 27.4 29.5 18.2 24.0 29.7 31.9 19.6 25.9 32.0 34.4 20.9 27.6 33.0 33.9 22.2 29.3 33.9 33.4 115°F 12.8 18.0 23.4 24.2 13.9 19.6 25.4 27.1 15.0 21.1 27.4 30.0 16.1 22.6 26.6 27.3 17.1 24.0 25.8 24.7 Sensible Capacity (MBH)* Return Dry Bulb (°F) † Total Total Cap.* Input (MBH) (kW) 77 74 71 68 86 83 18.2 23.4 28.9 32.4 19.7 25.5 31.5 35.3 21.3 27.5 34.0 38.1 22.5 29.1 37.0 38.5 23.8 30.8 39.9 38.9 16.1 21.4 26.9 30.3 17.3 23.1 29.1 32.9 18.6 24.8 31.3 35.4 19.5 26.1 34.0 35.5 20.5 27.5 36.7 35.6 19.3 24.8 28.3 20.7 26.7 30.5 22.0 28.6 32.7 23.1 31.0 32.5 24.2 33.4 32.3 17.2 22.7 26.2 18.3 24.3 28.1 19.3 25.8 30.0 20.2 28.0 29.5 21.0 30.2 29.1 44.6 39.5 34.7 34.0 46.3 41.0 36.0 35.3 48.0 42.5 37.4 36.6 48.8 43.2 38.0 37.2 49.6 43.9 38.6 37.8 2.6 2.5 2.5 2.5 2.6 2.6 2.5 2.5 2.6 2.6 2.6 2.5 2.6 2.6 2.6 2.5 2.6 2.6 2.6 2.5 22.7 28.0 33.4 34.0 24.9 30.7 35.4 35.3 27.1 33.4 37.4 36.6 29.1 35.7 38.0 37.2 31.1 38.1 38.6 37.8 20.6 25.9 31.3 34.0 22.6 28.3 34.2 35.3 24.5 30.7 37.0 36.6 26.2 32.8 37.8 37.2 27.8 34.9 38.6 37.8 14.7 20.1 25.3 27.4 15.8 21.7 27.3 29.6 17.0 23.2 29.3 31.7 18.0 24.7 30.1 31.0 19.0 26.1 30.8 30.3 12.6 18.0 23.2 25.3 13.5 19.3 25.0 27.2 14.3 20.6 26.7 29.1 15.1 21.8 27.1 28.1 15.9 22.9 27.6 27.1 15.9 21.2 23.2 16.9 22.6 24.8 18.0 24.1 26.5 18.9 24.2 25.2 19.8 24.4 23.9 13.8 19.1 21.1 14.6 20.2 22.5 15.3 21.4 23.8 16.0 21.3 22.3 16.6 21.2 20.7 36.5 32.1 28.3 27.5 37.4 32.9 29.0 28.2 38.2 33.6 29.6 28.8 38.4 33.8 29.8 28.9 38.5 33.9 29.9 29.1 3.0 3.0 2.9 2.9 3.0 3.0 2.9 2.9 3.1 3.0 3.0 2.9 3.1 3.0 3.0 2.9 3.1 3.0 3.0 2.9 18.9 24.2 28.3 27.5 20.7 26.4 29.0 28.2 22.5 28.7 29.6 28.8 24.1 30.5 29.8 28.9 25.8 32.3 29.9 29.1 16.8 22.1 27.4 27.5 18.4 24.1 28.5 28.2 19.9 26.1 29.6 28.8 21.3 27.9 29.8 28.9 22.7 29.7 29.9 29.1 10.9 16.1 21.4 22.3 11.7 17.3 23.2 23.5 12.5 18.6 24.9 24.8 13.3 19.8 23.9 23.2 14.2 21.1 22.9 21.7 8.9 14.1 19.5 20.3 9.4 15.1 20.9 22.5 10.0 16.1 22.3 24.8 10.6 17.1 21.1 21.8 11.2 18.1 19.9 18.8 12.1 17.5 18.4 12.8 18.7 20.4 13.5 19.8 22.4 14.4 18.4 19.1 15.2 17.0 15.8 10.2 15.6 16.4 10.6 16.4 18.1 11.0 17.3 19.9 11.6 15.7 16.4 12.2 14.0 12.8 29.3 24.7 22.5 21.0 29.2 24.5 22.3 20.8 29.0 24.4 22.2 20.7 28.8 24.1 22.0 20.5 28.5 23.9 21.8 20.3 3.5 3.4 3.3 3.3 3.5 3.4 3.3 3.3 3.5 3.4 3.4 3.3 3.5 3.4 3.4 3.3 3.6 3.5 3.4 3.4 14.7 19.8 22.5 21.0 16.2 21.7 22.3 20.8 17.7 23.7 22.2 20.7 19.0 24.1 22.0 20.5 20.3 23.9 21.8 20.3 12.8 17.9 22.5 21.0 14.0 19.5 22.3 20.8 15.2 21.2 22.2 20.7 16.3 22.7 22.0 20.5 17.4 23.9 21.8 20.3 80 18.6 23.9 29.2 32.0 20.2 25.9 31.8 34.8 21.8 28.0 34.3 37.6 23.2 29.8 36.5 37.7 24.6 31.7 38.6 37.8 105°F 14.8 20.1 25.4 26.9 16.1 21.8 27.6 29.5 17.3 23.5 29.7 32.2 18.5 25.1 29.8 30.6 19.7 26.7 29.9 29.1 125°F 10.9 16.0 21.4 21.0 11.8 17.3 22.3 20.8 12.7 18.7 22.2 20.7 13.7 20.1 22.0 20.5 14.6 21.4 21.8 20.3 77 74 71 68 16.5 21.8 27.1 29.9 17.8 23.6 29.4 32.4 19.1 25.4 31.7 34.9 20.3 26.9 33.5 34.7 21.4 28.4 35.4 34.6 14.4 19.7 25.1 27.8 15.4 21.2 27.0 30.0 16.4 22.7 29.0 32.2 17.3 24.0 30.6 31.8 18.2 25.2 32.1 31.3 17.6 23.0 25.7 18.8 24.6 27.6 20.0 26.3 29.6 21.0 27.6 28.8 22.0 28.9 28.1 15.5 20.9 23.7 16.4 22.3 25.3 17.3 23.6 26.9 18.1 24.7 25.9 18.8 25.7 24.9 12.8 18.1 23.4 24.8 13.8 19.5 25.3 26.5 14.7 20.9 27.1 28.2 15.7 22.3 27.0 27.1 16.6 23.6 26.8 26.0 10.8 16.1 21.4 22.8 11.5 17.2 22.9 24.9 12.2 18.3 24.5 26.9 12.8 19.4 24.1 24.9 13.5 20.5 23.8 22.9 14.0 19.3 20.8 14.9 20.6 22.6 15.7 21.9 24.4 16.6 21.3 22.1 17.5 20.7 19.9 12.0 17.3 18.8 12.6 18.3 20.3 13.2 19.4 21.8 13.8 18.5 19.3 14.4 17.6 16.8 9.0 14.1 19.5 19.7 9.6 15.2 21.1 20.5 10.3 16.3 22.2 20.7 11.0 17.4 20.8 19.4 11.7 18.6 18.9 17.4 7.1 12.2 17.6 17.8 7.4 13.0 18.9 20.2 7.8 13.8 20.2 20.7 8.3 14.8 18.1 18.6 8.9 15.7 16.1 14.6 10.3 15.7 15.9 10.8 16.7 18.1 11.3 17.7 20.4 12.1 15.5 16.1 12.9 13.3 11.7 8.4 13.8 14.0 8.6 14.5 16.0 8.8 15.2 17.9 9.4 12.8 13.4 10.0 10.4 8.9 1. The capacities are gross ratings. For net capacity, deduct indoor blower motor, MBH=3.415 x kW. Refer to the appropriate Blower Performance table for the kW of the supply air blower motor. 2. These ratings include the condensate fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. Unitary Products Group 23 036-21685-002-A-1105 TABLE 17: DR036 COOLING CAPACITIES (3 TON) - REHEAT MODE Temperature of Air on Condenser Coil Air on Evaporator Coil 75°F CFM 900 1050 1200 1350 1500 900 1050 1200 1350 1500 900 1050 1200 1350 1500 WB (°F) Total Total Cap.1 Input (MBH) (kW) 85°F * 2 Sensible Capacity (MBH) Return Dry Bulb (°F) 86 83 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 36.2 29.7 28.8 26.9 37.0 30.5 29.5 27.6 37.9 31.2 30.2 28.2 40.1 33.0 31.9 29.8 42.2 34.8 33.6 31.4 2.2 2.3 2.1 2.2 2.3 2.3 2.2 2.2 2.3 2.4 2.3 2.3 2.3 2.4 2.2 2.2 2.2 2.3 2.2 2.2 15.4 17.1 20.4 26.9 16.8 18.7 22.3 27.6 18.3 20.4 24.3 28.2 19.6 21.9 26.0 29.8 20.9 23.3 27.8 31.4 14.6 16.2 19.5 26.9 15.9 17.7 21.4 27.6 17.2 19.3 23.2 28.2 18.4 20.6 24.8 29.8 19.6 22.0 26.5 31.4 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 28.4 25.0 22.0 20.0 29.2 25.6 22.6 20.5 30.0 26.3 23.2 21.1 30.1 26.5 23.4 21.2 30.3 26.7 23.5 21.3 2.6 2.6 2.5 2.5 2.7 2.6 2.6 2.5 2.7 2.6 2.6 2.6 2.7 2.7 2.6 2.6 2.7 2.7 2.6 2.6 13.7 16.7 19.6 20.0 13.8 16.7 19.7 20.5 13.8 16.8 19.7 21.1 14.3 17.4 20.4 21.2 14.8 18.0 21.1 21.3 12.8 15.8 18.7 20.0 12.8 15.8 18.7 20.5 12.9 15.8 18.7 21.1 13.3 16.3 19.3 21.2 13.7 16.9 20.0 21.3 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 22.2 19.0 16.2 14.9 22.8 19.4 16.6 15.2 23.4 19.9 17.0 15.6 23.2 19.8 16.9 15.5 23.1 19.7 16.8 15.5 3.0 2.9 2.9 2.8 3.0 3.0 2.9 2.9 3.1 3.0 2.9 2.9 3.1 3.0 2.9 2.9 3.1 3.0 3.0 2.9 8.3 10.8 13.4 14.9 8.8 11.4 14.2 15.2 9.3 12.0 15.0 15.6 9.5 12.3 15.4 15.5 9.8 12.7 15.8 15.5 7.6 10.1 12.8 14.9 8.0 10.6 13.5 15.2 8.5 11.2 14.2 15.6 8.7 11.5 14.5 15.5 8.9 11.8 14.9 15.5 80 13.7 15.3 18.7 26.0 14.9 16.8 20.4 27.1 16.1 18.2 22.1 28.2 17.2 19.4 23.6 29.8 18.3 20.7 25.2 31.4 95°F 11.9 14.9 17.8 20.0 11.9 14.8 17.8 21.0 11.9 14.8 17.7 22.0 12.2 15.3 18.3 21.7 12.6 15.8 18.9 21.3 115°F 6.9 9.4 12.1 14.9 7.3 9.9 12.7 16.2 7.7 10.4 13.4 17.6 7.8 10.7 13.7 16.5 8.0 10.9 14.0 15.5 Sensible Capacity (MBH)* Return Dry Bulb (°F) † Total Total Cap.* Input (MBH) (kW) 77 74 71 68 86 83 12.8 14.5 17.8 25.1 13.9 15.8 19.4 26.1 15.0 17.1 21.0 27.1 16.0 18.2 22.4 28.6 17.0 19.4 23.8 30.0 12.0 13.6 17.0 24.3 12.9 14.8 18.4 25.1 13.9 16.0 19.9 26.0 14.8 17.0 21.2 27.4 15.6 18.0 22.5 28.7 12.8 16.1 23.4 13.8 17.5 24.2 14.9 18.8 24.9 15.8 20.0 26.2 16.7 21.2 27.4 11.9 15.3 22.6 12.9 16.5 23.2 13.8 17.7 23.8 14.6 18.8 25.0 15.4 19.9 26.1 32.3 27.3 25.4 23.5 33.1 28.0 26.1 24.1 33.9 28.7 26.7 24.6 35.1 29.7 27.6 25.5 36.3 30.7 28.6 26.4 2.4 2.4 2.3 2.3 2.5 2.5 2.4 2.4 2.5 2.5 2.4 2.4 2.5 2.5 2.4 2.4 2.5 2.5 2.4 2.4 14.6 16.9 20.0 23.5 15.3 17.7 21.0 24.1 16.1 18.6 22.0 24.6 17.0 19.6 23.2 25.5 17.9 20.7 24.4 26.4 13.7 16.0 19.1 23.5 14.4 16.8 20.0 24.1 15.0 17.5 21.0 24.6 15.8 18.5 22.1 25.5 16.7 19.4 23.2 26.4 11.0 13.9 16.9 19.1 10.9 13.9 16.8 20.0 10.9 13.8 16.7 21.0 11.2 14.2 17.2 20.6 11.5 14.6 17.8 20.2 10.0 13.0 15.9 18.1 10.0 12.9 15.8 19.1 9.9 12.8 15.8 20.0 10.1 13.2 16.2 19.6 10.4 13.5 16.6 19.1 12.1 15.0 17.2 12.0 14.9 18.1 11.8 14.8 19.0 12.1 15.2 18.5 12.4 15.5 18.0 11.1 14.1 16.3 11.0 13.9 17.2 10.9 13.8 18.1 11.1 14.1 17.5 11.3 14.4 16.9 25.3 22.0 19.1 17.4 26.0 22.5 19.6 17.9 26.7 23.1 20.1 18.3 26.7 23.1 20.1 18.4 26.7 23.2 20.2 18.4 2.8 2.8 2.7 2.7 2.8 2.8 2.7 2.7 2.9 2.8 2.8 2.7 2.9 2.8 2.8 2.8 2.9 2.9 2.8 2.8 11.0 13.7 16.5 17.4 11.3 14.1 16.9 17.9 11.5 14.4 17.3 18.3 11.9 14.9 17.9 18.4 12.3 15.3 18.4 18.4 10.2 12.9 15.7 17.4 10.4 13.2 16.1 17.9 10.7 13.5 16.5 18.3 11.0 13.9 16.9 18.4 11.3 14.3 17.4 18.4 6.2 8.7 11.4 14.2 6.5 9.2 12.0 14.9 6.9 9.6 12.6 15.6 7.0 9.8 12.9 15.1 7.1 10.0 13.1 14.6 5.6 8.0 10.7 13.5 5.8 8.4 11.3 14.6 6.1 8.8 11.8 15.6 6.2 9.0 12.0 14.7 6.3 9.2 12.3 13.7 7.4 10.0 12.8 7.7 10.5 14.0 8.0 11.0 15.2 8.1 11.2 14.0 8.3 11.4 12.8 6.7 9.4 12.2 6.9 9.8 13.3 7.2 10.2 14.4 7.3 10.3 13.2 7.4 10.5 12.0 19.1 16.0 13.2 12.3 19.6 16.3 13.5 12.6 20.1 16.7 13.9 12.9 19.8 16.5 13.7 12.7 19.5 16.3 13.5 12.5 3.2 3.1 3.0 3.0 3.2 3.1 3.1 3.0 3.3 3.2 3.1 3.1 3.3 3.2 3.1 3.1 3.3 3.2 3.1 3.1 5.5 7.8 10.3 12.3 6.3 8.7 11.5 12.6 7.0 9.6 12.6 12.9 7.1 9.8 12.9 12.7 7.3 10.0 13.1 12.5 5.0 7.2 9.8 12.3 5.6 8.1 10.8 12.6 6.3 8.9 11.9 12.9 6.4 9.1 12.1 12.7 6.5 9.2 12.4 12.5 80 12.8 15.1 18.2 23.0 13.4 15.8 19.1 24.1 14.0 16.5 19.9 25.1 14.7 17.4 21.0 25.7 15.4 18.2 22.0 26.4 105°F 9.4 12.1 14.9 17.4 9.6 12.4 15.2 18.6 9.8 12.6 15.6 19.8 10.0 13.0 16.0 19.1 10.3 13.3 16.4 18.4 125°F 4.4 6.7 9.2 12.3 5.0 7.4 10.2 12.6 5.6 8.2 11.2 12.9 5.6 8.3 11.4 12.7 5.7 8.5 11.6 12.5 77 74 71 68 11.9 14.2 17.3 22.1 12.4 14.8 18.1 23.1 12.9 15.5 18.9 24.1 13.6 16.2 19.8 24.6 14.2 17.0 20.8 25.1 11.0 13.3 16.4 21.2 11.5 13.9 17.1 22.1 11.9 14.4 17.8 23.0 12.5 15.1 18.7 23.5 13.0 15.8 19.6 23.9 12.4 15.6 20.3 12.9 16.2 21.1 13.4 16.8 22.0 14.0 17.6 22.3 14.6 18.4 22.7 11.5 14.7 19.4 11.9 15.2 20.2 12.3 15.7 20.9 12.8 16.4 21.2 13.4 17.1 21.5 8.6 11.3 14.1 16.6 8.7 11.5 14.4 17.5 8.9 11.7 14.7 18.3 9.1 12.0 15.1 17.9 9.3 12.3 15.4 17.4 7.8 10.5 13.3 15.8 7.9 10.7 13.5 16.8 8.0 10.8 13.8 17.8 8.2 11.1 14.1 17.1 8.3 11.3 14.5 16.4 9.7 12.5 15.0 9.8 12.7 16.1 9.9 12.9 17.1 10.1 13.2 16.3 10.4 13.5 15.4 8.9 11.7 14.2 9.0 11.9 15.2 9.0 12.0 16.2 9.2 12.2 15.3 9.4 12.5 14.4 3.9 6.1 8.7 11.7 4.4 6.8 9.6 12.3 4.9 7.5 10.5 12.9 4.9 7.6 10.7 12.3 5.0 7.7 10.8 11.8 3.3 5.6 8.1 11.2 3.7 6.2 9.0 12.3 4.2 6.8 9.8 12.9 4.2 6.9 9.9 12.2 4.2 7.0 10.1 11.0 5.0 7.6 10.6 5.6 8.3 11.9 6.1 9.1 12.9 6.1 9.2 11.7 6.2 9.3 10.2 4.5 7.0 10.1 4.9 7.7 11.3 5.4 8.4 12.5 5.4 8.5 11.0 5.4 8.6 9.5 1. The capacities are gross ratings. For net capacity, deduct indoor blower motor, MBH=3.415 x kW. Refer to the appropriate Blower Performance table for the kW of the supply air blower motor. 2. These ratings include the condensate fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. 24 Unitary Products Group 036-21685-002-A-1105 TABLE 18: DR048 COOLING CAPACITIES (4 TON) - NORMAL MODE Temperature of Air on Condenser Coil Air on Evaporator Coil CFM 1200 1400 1600 1800 2000 1200 1400 1600 1800 2000 1200 1400 1600 1800 2000 WB (°F) 75°F Total Total2 Cap.1 Input (MBH) (kW) 85°F Sensible Capacity (MBH)* Return Dry Bulb (°F) 86 83 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 57.4 53.2 48.8 48.4 58.5 54.2 49.7 49.3 59.6 55.2 50.7 50.2 61.7 57.2 52.5 52.0 63.9 59.1 54.3 53.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.9 2.9 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 2.8 33.0 39.3 48.1 48.4 36.3 43.1 49.4 49.3 39.6 47.0 50.7 50.2 42.3 50.5 52.5 52.0 45.0 54.0 54.3 53.8 30.1 36.3 43.9 45.5 33.0 39.8 47.3 47.9 35.9 43.2 50.7 50.2 38.2 46.1 52.5 52.0 40.6 48.9 54.3 53.8 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 49.1 45.2 41.7 41.2 50.5 46.5 42.9 42.4 51.9 47.8 44.1 43.6 52.0 47.8 44.1 43.7 52.1 47.9 44.2 43.7 3.4 3.4 3.3 3.3 3.4 3.4 3.3 3.3 3.4 3.4 3.3 3.4 3.4 3.4 3.4 3.4 3.5 3.4 3.4 3.4 30.5 35.8 41.7 41.2 33.5 39.2 42.9 42.4 36.5 42.7 44.1 43.6 39.0 45.3 44.1 43.7 41.6 47.9 44.2 43.7 27.7 33.0 40.2 39.8 30.3 36.0 42.1 41.7 32.9 39.1 44.1 43.6 35.1 41.7 44.1 43.7 37.3 44.3 44.2 43.7 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 43.1 38.0 35.2 35.3 43.8 38.5 35.7 35.8 44.4 39.1 36.2 36.3 44.2 38.9 36.0 36.2 44.0 38.7 35.8 36.0 4.0 3.9 3.8 3.8 4.0 3.9 3.8 3.9 4.0 3.9 3.9 3.9 4.1 4.0 3.9 3.9 4.1 4.0 4.0 4.0 25.2 32.6 35.2 35.3 27.8 35.8 35.7 35.8 30.5 39.1 36.2 36.3 32.6 38.9 36.0 36.2 34.8 38.7 35.8 36.0 22.3 29.8 33.3 33.4 24.6 32.7 34.8 34.9 26.8 35.7 36.2 36.3 28.6 37.2 36.0 36.2 30.4 38.7 35.8 36.0 80 27.2 33.4 41.0 42.6 29.6 36.4 44.7 46.4 32.1 39.5 48.4 50.2 34.1 42.0 51.3 52.0 36.2 44.5 54.3 53.8 95°F 24.8 30.1 37.4 37.0 27.1 32.8 40.7 40.3 29.3 35.5 44.1 43.6 31.1 37.8 44.1 43.7 33.0 40.0 44.2 43.7 115°F 19.5 26.9 30.5 30.6 21.3 29.5 33.3 33.4 23.1 32.0 36.2 36.3 24.6 34.0 36.0 36.2 26.1 36.1 35.8 36.0 Total Total† Cap.* Input (MBH) (kW) Sensible Capacity (MBH)* Return Dry Bulb (°F) 77 74 71 68 86 83 24.2 30.5 38.1 39.6 26.3 33.1 41.3 43.0 28.3 35.7 44.6 46.5 30.0 37.9 47.2 47.9 31.8 40.1 49.8 49.4 21.3 27.6 35.1 36.7 22.9 29.7 38.0 39.7 24.5 31.9 40.8 42.7 25.9 33.8 43.1 43.8 27.4 35.7 45.4 45.0 24.6 32.2 33.8 26.4 34.6 36.3 28.1 37.0 38.9 29.7 39.0 39.7 31.3 41.0 40.6 21.7 29.3 30.8 23.0 31.3 33.0 24.3 33.2 35.1 25.6 34.9 35.6 26.9 36.6 36.2 53.3 49.2 45.2 44.8 54.5 50.3 46.3 45.9 55.8 51.5 47.4 46.9 56.9 52.5 48.3 47.8 58.0 53.5 49.2 48.8 3.1 3.1 3.0 3.0 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 31.7 37.5 44.9 44.8 34.9 41.2 46.1 45.9 38.1 44.9 47.4 46.9 40.7 47.9 48.3 47.8 43.3 51.0 49.2 48.8 28.9 34.6 42.0 42.6 31.6 37.9 44.7 44.8 34.4 41.2 47.4 46.9 36.7 43.9 48.3 47.8 38.9 46.6 49.2 48.8 22.0 27.3 34.6 34.2 23.9 29.6 37.5 37.1 25.7 31.9 40.5 40.0 27.2 33.9 40.2 39.7 28.7 35.8 39.9 39.4 19.2 24.5 31.7 31.4 20.7 26.4 34.3 33.9 22.1 28.4 36.9 36.4 23.3 29.9 36.3 35.8 24.5 31.5 35.6 35.2 21.7 28.9 28.5 23.2 31.1 30.7 24.8 33.3 32.8 26.0 32.3 31.9 27.2 31.3 30.9 18.9 26.1 25.7 20.0 27.9 27.5 21.2 29.7 29.2 22.0 28.4 27.9 22.9 27.1 26.6 46.1 41.6 38.4 38.3 47.2 42.5 39.3 39.1 48.2 43.4 40.1 40.0 48.1 43.4 40.1 39.9 48.0 43.3 40.0 39.8 3.7 3.6 3.5 3.6 3.7 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.8 3.7 3.6 3.7 3.8 3.7 3.7 3.7 27.8 34.2 38.4 38.3 30.6 37.5 39.3 39.1 33.5 40.9 40.1 40.0 35.8 42.1 40.1 39.9 38.2 43.3 40.0 39.8 25.0 31.4 36.7 36.6 27.4 34.4 38.4 38.3 29.8 37.4 40.1 40.0 31.9 39.5 40.1 39.9 33.9 41.5 40.0 39.8 16.6 24.1 27.6 27.7 18.0 26.2 30.1 30.2 19.5 28.3 32.5 32.6 20.6 30.0 32.0 32.1 21.8 31.7 31.5 31.6 13.8 21.2 24.8 24.9 14.8 22.9 26.8 26.9 15.8 24.6 28.8 29.0 16.6 26.0 28.0 28.1 17.4 27.4 27.2 27.3 18.4 21.9 22.0 19.7 23.5 23.7 20.9 25.2 25.3 22.0 24.0 24.1 23.1 22.8 23.0 15.5 19.1 19.2 16.4 20.3 20.4 17.3 21.5 21.6 18.0 20.0 20.1 18.7 18.5 18.6 40.2 34.3 31.9 32.3 40.4 34.5 32.1 32.5 40.6 34.7 32.3 32.7 40.3 34.4 32.0 32.4 39.9 34.1 31.7 32.1 4.2 4.1 4.0 4.1 4.3 4.2 4.1 4.1 4.3 4.2 4.1 4.2 4.4 4.3 4.2 4.2 4.5 4.3 4.2 4.3 22.5 31.0 31.9 32.3 25.0 34.1 32.1 32.5 27.5 34.7 32.3 32.7 29.4 34.4 32.0 32.4 31.4 34.1 31.7 32.1 19.6 28.2 29.9 30.2 21.7 31.1 31.1 31.5 23.8 34.0 32.3 32.7 25.4 34.4 32.0 32.4 27.0 34.1 31.7 32.1 80 26.0 31.8 39.2 39.8 28.3 34.6 42.7 43.3 30.7 37.5 46.2 46.9 32.6 39.9 47.7 47.8 34.6 42.3 49.2 48.8 105°F 22.2 28.5 33.9 33.8 24.2 31.1 37.0 36.9 26.2 33.8 40.1 40.0 27.9 35.9 40.1 39.9 29.6 38.1 40.0 39.8 125°F 16.8 25.3 27.0 27.4 18.4 27.8 29.6 30.0 20.1 30.2 32.3 32.7 21.3 32.2 32.0 32.4 22.6 34.1 31.7 32.1 77 74 71 68 23.1 28.9 36.3 36.9 25.1 31.4 39.4 40.1 27.0 33.8 42.5 43.2 28.6 35.9 43.7 43.8 30.3 37.9 44.9 44.4 20.3 26.0 33.4 34.0 21.8 28.1 36.1 36.8 23.3 30.1 38.8 39.5 24.6 31.9 39.7 39.8 25.9 33.6 40.5 40.1 23.2 30.6 31.2 24.8 32.9 33.5 26.4 35.2 35.9 27.8 35.7 35.8 29.3 36.2 35.7 20.3 27.7 28.3 21.5 29.6 30.2 22.7 31.5 32.2 23.8 31.7 31.8 24.9 31.8 31.4 19.3 25.7 31.1 30.9 20.9 27.9 33.8 33.6 22.6 30.1 36.5 36.3 23.9 31.9 36.1 35.9 25.2 33.8 35.7 35.5 16.5 22.9 28.2 28.1 17.7 24.7 30.6 30.4 18.9 26.5 32.9 32.7 19.9 28.0 32.1 32.0 20.9 29.4 31.4 31.2 20.0 25.4 25.3 21.4 27.3 27.2 22.9 29.2 29.1 24.0 28.2 28.0 25.1 27.1 26.9 17.2 22.6 22.4 18.2 24.1 23.9 19.2 25.6 25.4 20.0 24.2 24.0 20.8 22.8 22.6 13.9 22.4 24.1 24.5 15.1 24.5 26.3 26.7 16.3 26.5 28.5 29.0 17.3 28.1 27.9 28.4 18.3 29.7 27.3 27.7 11.0 19.6 21.3 21.6 11.8 21.2 23.0 23.4 12.6 22.8 24.8 25.2 13.3 24.1 23.9 24.3 13.9 25.4 22.9 23.4 16.7 18.4 18.8 17.9 19.7 20.1 19.0 21.1 21.5 20.0 19.8 20.3 21.0 18.6 19.0 13.8 15.5 15.9 14.6 16.4 16.8 15.3 17.4 17.8 16.0 15.8 16.2 16.6 14.2 14.6 1. The capacities are gross ratings. For net capacity, deduct indoor blower motor, MBH=3.415 x kW. Refer to the appropriate Blower Performance table for the kW of the supply air blower motor. 2. These ratings include the condensate fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. Unitary Products Group 25 036-21685-002-A-1105 TABLE 19: DR048 COOLING CAPACITIES (4 TON) - REHEAT MODE Temperature of Air on Condenser Coil Air on Evaporator Coil CFM 1200 1400 1600 1800 2000 1200 1400 1600 1800 2000 1200 1400 1600 1800 2000 WB (°F) 75°F Total Total2 Cap.1 Input (MBH) (kW) 85°F Sensible Capacity (MBH)* Return Dry Bulb (°F) 86 83 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 41.4 37.6 33.8 30.4 43.7 39.6 35.6 32.0 45.9 41.7 37.4 33.7 47.4 43.0 38.7 34.8 48.9 44.4 39.9 35.9 2.8 2.7 2.7 2.6 2.8 2.7 2.7 2.7 2.8 2.7 2.7 2.7 2.8 2.8 2.7 2.7 2.9 2.8 2.8 2.7 18.5 24.2 26.7 30.4 20.4 26.7 29.5 32.0 22.4 29.1 32.2 33.7 23.1 30.1 33.2 34.8 23.8 31.0 34.1 35.9 17.3 22.9 25.5 29.3 19.0 25.2 28.0 31.5 20.8 27.6 30.6 33.7 21.4 28.3 31.5 34.8 22.0 29.1 32.3 35.9 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 36.6 32.6 29.9 27.5 38.0 33.8 31.1 28.5 39.3 35.1 32.2 29.5 40.3 35.9 33.0 30.2 41.2 36.8 33.7 30.9 3.2 3.1 3.1 3.0 3.3 3.2 3.1 3.0 3.3 3.2 3.1 3.1 3.3 3.2 3.2 3.1 3.4 3.3 3.2 3.1 17.1 21.2 25.1 27.5 18.4 22.8 26.9 28.5 19.6 24.3 28.7 29.5 20.8 25.7 30.3 30.2 21.9 27.1 32.0 30.9 15.9 20.0 23.9 27.2 17.0 21.4 25.5 28.4 18.2 22.8 27.2 29.5 19.2 24.1 28.7 30.2 20.2 25.4 30.3 30.9 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 30.2 27.4 24.3 23.7 31.4 28.5 25.3 24.6 32.6 29.6 26.3 25.5 33.0 30.0 26.6 25.9 33.5 30.4 27.0 26.2 3.7 3.5 3.4 3.4 3.7 3.6 3.5 3.4 3.8 3.6 3.5 3.5 3.8 3.7 3.5 3.5 3.8 3.7 3.6 3.5 13.7 17.8 21.3 23.7 15.0 19.5 23.2 24.6 16.4 21.1 25.2 25.5 17.4 22.5 26.1 25.9 18.5 23.9 27.0 26.2 12.7 16.7 20.2 22.8 13.8 18.3 22.0 24.2 15.0 19.8 23.8 25.5 15.9 21.0 25.4 25.9 16.9 22.3 26.9 26.2 80 16.0 21.7 24.2 28.0 17.6 23.8 26.6 30.9 19.2 26.0 29.1 33.7 19.7 26.6 29.8 34.8 20.2 27.3 30.5 35.9 95°F 14.7 18.9 22.7 26.1 15.7 20.1 24.2 27.8 16.7 21.4 25.7 29.5 17.6 22.6 27.1 30.2 18.5 23.7 28.6 30.9 115°F 11.6 15.7 19.1 21.7 12.6 17.0 20.8 23.6 13.6 18.4 22.5 25.5 14.5 19.6 23.9 25.9 15.3 20.7 25.3 26.2 Total Total† Cap.* Input (MBH) (kW) Sensible Capacity (MBH)* Return Dry Bulb (°F) 77 74 71 68 86 83 14.7 20.4 22.9 26.8 16.2 22.4 25.2 29.4 17.6 24.4 27.5 32.1 18.0 24.9 28.1 33.1 18.3 25.5 28.7 34.1 13.5 19.1 21.7 25.5 14.8 21.0 23.8 28.0 16.0 22.8 25.9 30.5 16.3 23.2 26.4 31.4 16.5 23.6 26.8 32.3 17.9 20.4 24.3 19.6 22.4 26.6 21.2 24.3 28.9 21.5 24.7 29.7 21.8 25.0 30.4 16.6 19.1 23.0 18.1 20.9 25.2 19.6 22.7 27.4 19.8 23.0 28.0 20.0 23.2 28.6 39.0 35.1 31.8 28.9 40.8 36.7 33.3 30.3 42.6 38.4 34.8 31.6 43.9 39.5 35.8 32.5 45.1 40.6 36.8 33.4 3.0 2.9 2.9 2.8 3.0 2.9 2.9 2.8 3.1 3.0 2.9 2.9 3.1 3.0 3.0 2.9 3.1 3.0 3.0 2.9 17.8 22.7 25.9 28.9 19.4 24.7 28.2 30.3 21.0 26.7 30.5 31.6 21.9 27.9 31.8 32.5 22.9 29.0 33.0 33.4 16.6 21.5 24.7 28.3 18.0 23.3 26.8 29.9 19.5 25.2 28.9 31.6 20.3 26.2 30.1 32.5 21.1 27.3 31.3 33.4 13.5 17.7 21.5 24.9 14.4 18.8 22.9 26.5 15.2 19.9 24.2 28.1 16.0 21.0 25.6 28.7 16.8 22.1 26.9 29.3 12.3 16.5 20.3 23.7 13.0 17.4 21.5 25.1 13.7 18.4 22.8 26.6 14.4 19.4 24.0 27.1 15.2 20.4 25.2 27.6 15.3 19.1 22.5 16.1 20.2 23.8 16.9 21.3 25.1 17.8 22.4 25.5 18.7 23.5 25.9 14.1 18.0 21.3 14.8 18.9 22.5 15.4 19.8 23.6 16.2 20.8 23.9 17.0 21.8 24.2 33.4 30.0 27.1 25.6 34.7 31.2 28.2 26.6 36.0 32.3 29.2 27.5 36.7 33.0 29.8 28.1 37.3 33.6 30.4 28.6 3.4 3.3 3.2 3.2 3.5 3.4 3.3 3.2 3.5 3.4 3.3 3.3 3.6 3.4 3.4 3.3 3.6 3.5 3.4 3.3 15.4 19.5 23.2 25.6 16.7 21.1 25.1 26.6 18.0 22.7 26.9 27.5 19.1 24.1 28.2 28.1 20.2 25.5 29.5 28.6 14.3 18.4 22.0 25.0 15.4 19.8 23.8 26.3 16.6 21.3 25.5 27.5 17.6 22.6 27.0 28.1 18.6 23.9 28.6 28.6 10.5 14.6 18.0 20.6 11.4 15.8 19.6 22.4 12.3 17.0 21.1 24.2 13.0 18.1 22.4 24.4 13.7 19.1 23.7 24.7 9.4 13.5 17.0 19.6 10.2 14.6 18.4 21.2 10.9 15.7 19.8 22.8 11.5 16.6 20.9 22.9 12.2 17.5 22.1 23.1 12.4 15.9 18.5 13.4 17.1 20.0 14.3 18.4 21.4 15.1 19.5 21.5 16.0 20.5 21.5 11.4 14.8 17.4 12.1 15.9 18.7 12.9 17.0 20.1 13.7 18.0 20.0 14.4 19.0 19.9 27.0 24.8 21.5 21.8 28.1 25.8 22.4 22.7 29.2 26.9 23.3 23.5 29.4 27.0 23.5 23.7 29.6 27.2 23.6 23.9 3.9 3.7 3.6 3.6 3.9 3.8 3.7 3.6 4.0 3.9 3.7 3.7 4.0 3.9 3.7 3.7 4.0 3.9 3.7 3.7 12.1 16.1 19.4 21.8 13.4 17.8 21.4 22.7 14.7 19.5 23.3 23.5 15.7 20.9 23.5 23.7 16.7 22.2 23.6 23.9 11.0 15.1 18.4 20.6 12.2 16.7 20.3 22.1 13.4 18.2 22.2 23.5 14.3 19.5 23.5 23.7 15.2 20.7 23.6 23.9 80 15.4 20.3 23.4 27.1 16.7 22.0 25.4 29.3 17.9 23.7 27.4 31.6 18.6 24.6 28.5 32.5 19.3 25.5 29.5 33.4 105°F 13.2 17.3 20.9 23.9 14.1 18.6 22.5 25.7 15.1 19.9 24.1 27.5 16.0 21.1 25.5 28.1 16.9 22.2 26.9 28.6 125°F 10.0 14.1 17.3 19.6 11.1 15.5 19.1 21.6 12.1 16.9 20.9 23.5 12.9 18.1 22.3 23.7 13.7 19.2 23.6 23.9 77 74 71 68 14.1 19.0 22.2 25.8 15.3 20.6 24.0 28.0 16.4 22.1 25.9 30.1 17.0 23.0 26.8 30.9 17.6 23.8 27.8 31.7 12.9 17.8 21.0 24.6 13.9 19.2 22.7 26.6 14.9 20.6 24.3 28.5 15.4 21.3 25.2 29.2 15.8 22.0 26.0 29.9 16.6 19.8 23.4 17.8 21.3 25.2 19.1 22.8 27.0 19.7 23.5 27.6 20.2 24.3 28.2 15.4 18.5 22.2 16.5 19.9 23.8 17.5 21.3 25.5 18.0 21.9 25.9 18.5 22.5 26.4 12.0 16.1 19.8 22.8 12.9 17.3 21.2 24.4 13.7 18.5 22.7 26.1 14.5 19.5 24.0 26.5 15.3 20.6 25.3 27.0 10.9 15.0 18.6 21.6 11.6 16.0 19.9 23.2 12.3 17.0 21.3 24.7 13.0 18.0 22.5 25.0 13.7 19.0 23.7 25.3 13.9 17.5 20.5 14.7 18.7 21.9 15.6 19.8 23.3 16.5 20.9 23.5 17.3 22.0 23.7 12.7 16.4 19.4 13.5 17.4 20.6 14.2 18.4 21.8 14.9 19.4 21.9 15.7 20.4 22.1 9.0 13.0 16.3 18.5 9.9 14.3 17.9 20.4 10.8 15.6 19.6 22.2 11.5 16.6 20.8 22.3 12.2 17.7 22.1 22.4 8.0 12.0 15.3 17.5 8.7 13.2 16.8 19.2 9.5 14.3 18.3 20.9 10.1 15.2 19.4 20.9 10.7 16.1 20.6 20.8 11.0 14.3 16.5 12.0 15.6 18.1 13.0 16.9 19.6 13.8 18.0 19.5 14.6 19.1 19.3 10.0 13.2 15.5 10.8 14.4 16.9 11.7 15.6 18.3 12.4 16.6 18.1 13.1 17.5 17.8 1. The capacities are gross ratings. For net capacity, deduct indoor blower motor, MBH=3.415 x kW. Refer to the appropriate Blower Performance table for the kW of the supply air blower motor. 2. These ratings include the condensate fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. 26 Unitary Products Group 036-21685-002-A-1105 TABLE 20: DR060 COOLING CAPACITIES (5 TON) - NORMAL MODE Temperature of Air on Condenser Coil Air on Evaporator Coil CFM 1500 1750 2000 2250 2500 1500 1750 2000 2250 2500 1500 1750 2000 2250 2500 WB (°F) 75°F Total Total2 Cap.1 Input (MBH) (kW) 85°F Sensible Capacity (MBH)* Return Dry Bulb (°F) 86 83 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 68.8 63.4 57.5 56.0 70.4 64.9 58.8 57.3 71.9 66.3 60.2 58.6 73.5 67.8 61.5 59.9 75.1 69.3 62.8 61.2 3.4 3.4 3.3 3.3 3.4 3.4 3.3 3.3 3.4 3.4 3.3 3.3 3.4 3.4 3.3 3.3 3.5 3.4 3.3 3.3 38.3 47.2 57.0 56.0 40.8 50.1 58.6 57.3 43.2 53.0 60.2 58.6 47.2 57.9 61.5 59.9 51.1 62.8 62.8 61.2 34.9 43.9 52.9 56.0 36.9 46.2 56.0 57.3 38.8 48.6 59.0 58.6 42.5 53.2 60.9 59.9 46.2 57.9 62.8 61.2 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 63.0 57.3 52.4 51.4 64.1 58.3 53.3 52.4 65.3 59.4 54.3 53.3 66.8 60.7 55.5 54.5 68.3 62.1 56.7 55.7 4.3 4.2 4.2 4.2 4.3 4.2 4.2 4.2 4.3 4.3 4.2 4.2 4.3 4.3 4.2 4.2 4.3 4.3 4.2 4.2 35.1 44.3 52.4 51.4 37.4 47.0 53.3 52.4 39.6 49.6 54.3 53.3 43.3 54.3 55.5 54.5 47.0 58.9 56.7 55.7 31.8 41.0 49.7 51.4 33.6 43.2 52.0 52.4 35.3 45.3 54.3 53.3 38.7 49.7 55.5 54.5 42.0 54.0 56.7 55.7 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 56.0 50.4 46.6 46.3 56.7 51.0 47.2 46.9 57.4 51.7 47.8 47.5 58.6 52.7 48.8 48.4 59.7 53.7 49.7 49.4 5.3 5.3 5.2 5.2 5.3 5.3 5.2 5.2 5.3 5.3 5.2 5.2 5.4 5.3 5.2 5.2 5.4 5.3 5.3 5.3 32.3 41.2 46.6 46.3 34.2 43.4 47.2 46.9 36.0 45.6 47.8 47.5 39.5 49.7 48.8 48.4 43.1 53.7 49.7 49.4 29.0 37.9 46.6 46.3 30.4 39.7 47.2 46.9 31.8 41.4 47.8 47.5 35.1 45.6 48.8 48.4 38.3 49.9 49.7 49.4 80 31.6 40.6 49.6 54.4 33.0 42.4 51.8 56.8 34.4 44.2 54.1 59.3 37.9 48.6 58.4 60.3 41.3 53.0 62.8 61.2 95°F 28.4 37.6 46.3 49.1 29.7 39.3 48.4 51.4 31.0 41.0 50.5 53.6 34.1 45.1 53.6 54.6 37.1 49.1 56.7 55.7 115°F 25.7 34.6 44.0 44.4 26.7 35.9 45.7 46.0 27.7 37.3 47.4 47.7 30.6 41.2 48.5 48.6 33.5 45.1 49.7 49.4 Total Total† Cap.* Input (MBH) (kW) Sensible Capacity (MBH)* Return Dry Bulb (°F) 77 74 71 68 86 83 28.3 37.2 46.3 51.1 29.2 38.5 48.0 53.0 30.1 39.8 49.7 54.9 33.2 43.9 53.8 55.6 36.4 48.1 57.9 56.3 24.9 33.9 42.9 47.7 25.3 34.7 44.1 49.1 25.7 35.4 45.3 50.5 28.6 39.3 49.1 51.0 31.5 43.1 53.0 51.4 30.6 39.6 44.4 30.8 40.3 45.3 31.1 40.9 46.1 34.7 44.5 46.3 38.2 48.1 46.5 27.2 36.3 41.0 26.9 36.4 41.4 26.7 36.5 41.7 30.0 39.9 41.7 33.3 43.2 41.6 65.9 60.3 54.9 53.7 67.2 61.6 56.1 54.9 68.6 62.9 57.2 56.0 70.2 64.3 58.5 57.2 71.7 65.7 59.8 58.5 3.8 3.8 3.8 3.7 3.9 3.8 3.8 3.8 3.9 3.8 3.8 3.8 3.9 3.8 3.8 3.8 3.9 3.8 3.8 3.8 36.7 45.8 54.7 53.7 39.1 48.5 55.9 54.9 41.4 51.3 57.2 56.0 45.2 56.1 58.5 57.2 49.0 60.9 59.8 58.5 33.4 42.4 51.3 53.7 35.2 44.7 54.0 54.9 37.1 47.0 56.6 56.0 40.6 51.5 58.2 57.2 44.1 55.9 59.8 58.5 25.1 34.3 43.0 45.8 25.9 35.5 44.6 47.5 26.7 36.7 46.2 49.3 29.5 40.4 49.0 50.0 32.2 44.2 51.8 50.8 21.7 30.9 39.6 42.4 22.1 31.7 40.8 43.7 22.4 32.4 41.9 45.0 24.8 35.8 44.4 45.4 27.3 39.2 46.9 45.9 27.6 36.3 39.1 27.8 37.0 39.9 28.1 37.6 40.7 31.2 39.8 40.8 34.3 42.0 40.9 24.2 32.9 35.7 24.0 33.1 36.0 23.8 33.3 36.4 26.6 35.2 36.2 29.4 37.0 36.0 59.5 53.8 49.5 48.8 60.4 54.7 50.3 49.6 61.4 55.5 51.0 50.4 62.7 56.7 52.1 51.5 64.0 57.9 53.2 52.6 4.8 4.7 4.7 4.7 4.8 4.8 4.7 4.7 4.8 4.8 4.7 4.7 4.8 4.8 4.7 4.7 4.8 4.8 4.7 4.7 33.7 42.8 49.5 48.8 35.8 45.2 50.3 49.6 37.8 47.6 51.0 50.4 41.4 52.0 52.1 51.5 45.0 56.3 53.2 52.6 30.4 39.5 48.1 48.8 32.0 41.4 49.6 49.6 33.6 43.4 51.0 50.4 36.9 47.7 52.1 51.5 40.2 51.9 53.2 52.6 22.5 31.4 40.8 41.1 23.0 32.2 42.0 42.3 23.5 33.1 43.2 43.6 26.1 36.7 44.1 44.1 28.7 40.3 44.9 44.6 19.2 28.1 37.5 37.8 19.3 28.5 38.3 38.6 19.4 28.9 39.1 39.4 21.7 32.2 39.6 39.6 23.9 35.5 40.2 39.8 24.8 34.2 34.5 24.8 34.5 34.9 24.8 34.9 35.3 27.8 35.1 35.2 30.8 35.4 35.1 21.5 30.9 31.2 21.1 30.8 31.2 20.6 30.7 31.1 23.3 30.7 30.7 26.0 30.6 30.3 52.5 46.9 43.7 43.7 53.0 47.4 44.1 44.1 53.5 47.8 44.5 44.6 54.5 48.7 45.4 45.4 55.5 49.6 46.2 46.2 5.9 5.8 5.7 5.7 5.9 5.8 5.7 5.7 5.9 5.8 5.7 5.8 5.9 5.8 5.8 5.8 5.9 5.8 5.8 5.8 30.9 39.7 43.7 43.7 32.5 41.6 44.1 44.1 34.2 43.5 44.5 44.6 37.7 47.3 45.4 45.4 41.1 49.6 46.2 46.2 27.6 36.4 43.7 43.7 28.9 37.9 44.1 44.1 30.1 39.4 44.5 44.6 33.3 43.6 45.4 45.4 36.4 47.8 46.2 46.2 80 30.0 39.1 48.0 51.8 31.4 40.9 50.1 54.1 32.7 42.6 52.3 56.4 36.0 46.8 56.0 57.5 39.2 51.0 59.8 58.5 105°F 27.1 36.1 45.2 46.8 28.2 37.6 47.1 48.7 29.4 39.1 49.0 50.6 32.3 43.1 51.1 51.6 35.3 47.1 53.2 52.6 125°F 24.4 33.2 42.9 42.0 25.2 34.3 44.1 43.4 26.0 35.4 44.5 44.6 28.9 39.2 45.4 45.4 31.7 43.1 46.2 46.2 77 74 71 68 26.7 35.8 44.6 48.4 27.5 37.0 46.3 50.2 28.4 38.3 48.0 52.1 31.3 42.2 51.4 52.8 34.3 46.1 54.9 53.6 23.3 32.4 41.3 45.1 23.7 33.2 42.5 46.4 24.1 33.9 43.6 47.7 26.7 37.6 46.8 48.2 29.4 41.2 49.9 48.6 29.1 37.9 41.7 29.3 38.6 42.6 29.6 39.3 43.4 32.9 42.2 43.6 36.3 45.0 43.7 25.7 34.6 38.4 25.5 34.8 38.7 25.3 34.9 39.1 28.3 37.5 38.9 31.4 40.1 38.8 23.8 32.8 41.9 43.4 24.4 33.9 43.3 44.9 25.1 34.9 44.7 46.4 27.8 38.6 46.5 47.1 30.5 42.2 48.4 47.7 20.5 29.5 38.6 40.1 20.7 30.1 39.5 41.2 20.9 30.7 40.5 42.2 23.3 34.0 42.0 42.5 25.6 37.4 43.5 42.8 26.2 35.2 36.8 26.3 35.8 37.4 26.5 36.3 38.0 29.5 37.5 38.0 32.5 38.7 38.0 22.9 31.9 33.5 22.5 32.0 33.6 22.2 32.0 33.7 25.0 32.9 33.4 27.7 33.8 33.1 21.1 29.9 39.6 38.7 21.5 30.6 40.7 39.7 21.9 31.3 41.7 40.7 24.5 34.8 41.6 41.1 27.0 38.4 41.5 41.5 17.9 26.6 36.4 35.5 17.9 26.9 37.0 36.1 17.9 27.2 37.6 36.6 20.1 30.4 37.2 36.7 22.3 33.7 36.8 36.8 23.4 33.1 32.2 23.3 33.3 32.4 23.1 33.5 32.6 26.0 32.8 32.3 29.0 32.1 32.1 20.1 29.9 29.0 19.6 29.7 28.7 19.0 29.5 28.5 21.7 28.4 27.9 24.3 27.4 27.4 1. The capacities are gross ratings. For net capacity, deduct indoor blower motor, MBH=3.415 x kW. Refer to the appropriate Blower Performance table for the kW of the supply air blower motor. 2. These ratings include the condensate fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. Unitary Products Group 27 036-21685-002-A-1105 TABLE 21: DR060 COOLING CAPACITIES (5 TON) - REHEAT MODE Temperature of Air on Condenser Coil Air on Evaporator Coil CFM 1500 1750 2000 2250 2500 1500 1750 2000 2250 2500 1500 1750 2000 2250 2500 WB (°F) 75°F Total Total2 Cap.1 Input (MBH) (kW) 85°F Sensible Capacity (MBH)* Return Dry Bulb (°F) 86 83 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 49.3 45.3 40.9 36.1 49.9 45.9 41.4 36.6 50.6 46.5 41.9 37.0 52.3 48.1 43.4 38.3 54.1 49.7 44.9 39.5 3.4 3.3 3.3 3.2 3.3 3.3 3.2 3.2 3.3 3.2 3.2 3.1 3.3 3.2 3.2 3.1 3.3 3.2 3.2 3.1 35.4 42.0 47.9 36.1 30.4 36.0 41.1 36.6 25.4 30.0 34.3 37.0 26.9 31.8 36.4 38.3 28.4 33.6 38.5 39.5 33.4 40.0 46.4 36.7 28.5 34.2 39.5 36.9 23.7 28.3 32.7 37.1 25.2 30.1 34.7 38.3 26.7 31.8 36.7 39.5 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 42.9 39.0 35.7 33.2 44.4 40.4 36.9 34.3 45.9 41.7 38.1 35.4 47.6 43.3 39.6 36.8 49.4 44.9 41.0 38.2 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.2 4.1 4.1 4.1 4.2 4.2 4.1 4.1 20.3 24.5 28.7 33.2 21.3 25.7 30.0 34.3 22.4 26.9 31.4 35.4 23.9 28.7 33.6 36.8 25.5 30.6 35.8 38.2 19.1 23.2 27.4 32.5 19.9 24.3 28.6 34.0 20.8 25.3 29.8 35.4 22.3 27.1 32.0 36.8 23.8 28.9 34.1 38.2 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 38.3 34.5 31.7 29.3 39.3 35.5 32.6 30.1 40.4 36.4 33.4 31.0 41.7 37.6 34.5 32.0 43.0 38.8 35.6 33.0 5.2 5.2 5.1 5.2 5.2 5.2 5.1 5.2 5.2 5.2 5.1 5.2 5.2 5.2 5.1 5.2 5.2 5.2 5.1 5.2 17.3 21.4 25.5 29.3 18.1 22.5 26.7 30.1 19.0 23.5 27.9 31.0 20.4 25.2 29.9 32.0 21.7 26.9 31.9 33.0 16.1 20.3 24.4 28.7 16.9 21.2 25.4 29.8 17.6 22.1 26.5 31.0 18.9 23.7 28.4 32.0 20.2 25.4 30.4 33.0 80 31.3 38.0 44.3 38.0 26.7 32.3 37.7 37.1 22.1 26.7 31.0 36.2 23.5 28.4 33.0 37.9 24.9 30.1 35.0 39.5 95°F 17.8 22.0 26.2 31.3 18.5 22.9 27.2 32.6 19.3 23.8 28.3 33.8 20.7 25.5 30.4 36.0 22.1 27.2 32.4 38.2 115°F 15.0 19.2 23.2 27.5 15.6 19.9 24.1 28.6 16.2 20.7 25.0 29.7 17.4 22.2 26.9 31.3 18.6 23.8 28.8 33.0 Total Total† Cap.* Input (MBH) (kW) Sensible Capacity (MBH)* Return Dry Bulb (°F) 77 74 71 68 86 83 29.3 35.9 42.3 35.9 24.9 30.5 35.9 35.2 20.5 25.0 29.4 34.5 21.8 26.7 31.3 36.2 23.2 28.3 33.3 37.8 27.3 33.9 40.3 33.9 23.1 28.7 34.0 33.4 18.8 23.4 27.8 32.9 20.1 25.0 29.6 34.5 21.4 26.6 31.5 36.1 31.9 38.3 31.9 26.8 32.2 31.6 21.8 26.1 31.3 23.3 28.0 32.8 24.9 29.8 34.3 29.9 36.2 29.9 25.0 30.4 29.7 20.1 24.5 29.6 21.6 26.3 31.1 23.1 28.0 32.6 46.1 42.2 38.3 34.6 47.2 43.1 39.2 35.4 48.2 44.1 40.0 36.2 50.0 45.7 41.5 37.5 51.7 47.3 42.9 38.9 3.7 3.7 3.7 3.6 3.7 3.7 3.7 3.6 3.7 3.7 3.7 3.6 3.7 3.7 3.7 3.6 3.7 3.7 3.7 3.6 27.8 33.2 38.3 34.6 25.9 30.8 35.6 35.4 23.9 28.4 32.9 36.2 25.4 30.3 35.0 37.5 26.9 32.1 37.1 38.9 26.2 31.6 36.9 34.6 24.2 29.2 34.1 35.4 22.3 26.8 31.3 36.2 23.7 28.6 33.3 37.5 25.2 30.4 35.4 38.9 16.6 20.8 25.0 30.1 17.2 21.5 25.9 31.2 17.7 22.2 26.7 32.3 19.0 23.9 28.7 34.4 20.4 25.6 30.7 36.5 15.4 19.5 23.7 28.9 15.8 20.1 24.5 29.8 16.2 20.7 25.2 30.7 17.4 22.3 27.1 32.7 18.7 23.9 29.1 34.8 18.3 22.5 27.6 18.7 23.1 28.4 19.1 23.6 29.2 20.6 25.5 31.1 22.2 27.4 33.1 17.1 21.3 26.4 17.3 21.7 27.0 17.6 22.1 27.6 19.0 23.9 29.5 20.5 25.7 31.4 40.6 36.8 33.7 31.3 41.9 37.9 34.7 32.2 43.1 39.0 35.8 33.2 44.7 40.4 37.1 34.4 46.2 41.8 38.3 35.6 4.7 4.7 4.6 4.6 4.7 4.7 4.6 4.6 4.7 4.7 4.6 4.6 4.7 4.7 4.6 4.6 4.7 4.7 4.6 4.6 18.8 23.0 27.1 31.3 19.7 24.1 28.4 32.2 20.7 25.2 29.6 33.2 22.1 27.0 31.8 34.4 23.6 28.8 33.9 35.6 17.6 21.8 25.9 30.6 18.4 22.7 27.0 31.9 19.2 23.7 28.2 33.2 20.6 25.4 30.2 34.4 22.0 27.1 32.3 35.6 13.9 18.1 22.1 26.4 14.3 18.6 22.8 27.3 14.7 19.2 23.6 28.3 15.9 20.8 25.4 29.8 17.1 22.3 27.3 31.4 12.7 16.9 21.0 25.3 13.0 17.4 21.6 26.1 13.3 17.8 22.2 26.8 14.4 19.3 24.0 28.4 15.5 20.7 25.7 29.9 15.8 19.8 24.2 16.1 20.3 24.8 16.4 20.7 25.4 17.8 22.5 26.9 19.2 24.2 28.4 14.7 18.7 23.0 14.8 19.0 23.5 14.9 19.3 24.0 16.3 21.0 25.4 17.6 22.7 26.8 36.0 32.3 29.7 27.4 36.8 33.0 30.4 28.1 37.6 33.7 31.1 28.7 38.8 34.7 32.0 29.6 39.9 35.8 32.9 30.4 5.8 5.7 5.6 5.7 5.8 5.7 5.6 5.7 5.8 5.7 5.6 5.7 5.8 5.7 5.6 5.7 5.8 5.7 5.6 5.7 15.7 19.9 23.9 27.4 16.5 20.9 25.0 28.1 17.3 21.9 26.1 28.7 18.6 23.5 28.1 29.6 19.8 25.1 30.0 30.4 14.7 18.9 22.8 26.7 15.3 19.7 23.8 27.7 16.0 20.5 24.8 28.7 17.2 22.0 26.6 29.6 18.4 23.6 28.5 30.4 80 24.6 30.0 35.3 34.6 22.6 27.6 32.5 34.8 20.7 25.2 29.7 35.0 22.1 26.9 31.7 36.9 23.5 28.7 33.7 38.9 105°F 16.4 20.6 24.7 29.4 17.1 21.4 25.7 30.6 17.7 22.2 26.7 31.7 19.0 23.9 28.7 33.7 20.3 25.5 30.6 35.6 125°F 13.6 17.8 21.7 25.7 14.1 18.5 22.6 26.6 14.6 19.1 23.4 27.6 15.7 20.6 25.2 29.0 16.9 22.1 27.0 30.4 77 74 71 68 23.0 28.4 33.6 33.0 21.0 26.0 30.9 33.2 19.1 23.6 28.1 33.4 20.4 25.3 30.0 35.3 21.8 26.9 32.0 37.1 21.3 26.7 32.0 31.4 19.4 24.4 29.2 31.6 17.5 22.0 26.5 31.8 18.8 23.6 28.4 33.6 20.1 25.2 30.3 35.4 25.1 30.4 29.8 22.8 27.6 30.0 20.4 24.9 30.2 22.0 26.7 32.0 23.5 28.6 33.7 23.5 28.8 28.1 21.2 26.0 28.4 18.8 23.3 28.6 20.3 25.1 30.3 21.8 26.9 32.0 15.2 19.4 23.5 28.2 15.7 20.1 24.4 29.3 16.2 20.7 25.2 30.3 17.5 22.3 27.1 32.1 18.7 23.9 29.0 34.0 14.1 18.2 22.4 27.1 14.4 18.7 23.0 27.9 14.7 19.2 23.7 28.8 15.9 20.8 25.5 30.6 17.1 22.3 27.4 32.3 17.1 21.2 25.9 17.4 21.7 26.6 17.7 22.2 27.3 19.2 24.0 29.0 20.7 25.8 30.7 15.9 20.0 24.7 16.1 20.3 25.2 16.3 20.7 25.8 17.7 22.4 27.4 19.1 24.2 29.1 12.5 16.7 20.7 24.6 12.9 17.2 21.3 25.4 13.2 17.8 22.0 26.2 14.3 19.2 23.8 27.6 15.4 20.6 25.6 28.9 11.4 15.6 19.6 23.5 11.6 16.0 20.1 24.2 11.9 16.4 20.7 24.9 12.9 17.8 22.4 26.2 13.9 19.2 24.1 27.5 14.5 18.5 22.4 14.8 18.9 23.0 15.0 19.3 23.5 16.3 21.0 24.7 17.7 22.6 26.0 13.4 17.4 21.3 13.5 17.7 21.7 13.6 17.9 22.1 14.9 19.5 23.3 16.2 21.1 24.5 1. The capacities are gross ratings. For net capacity, deduct indoor blower motor, MBH=3.415 x kW. Refer to the appropriate Blower Performance table for the kW of the supply air blower motor. 2. These ratings include the condensate fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. 28 Unitary Products Group 036-21685-002-A-1105 TABLE 22: DR072 COOLING CAPACITIES (6 TON) - NORMAL MODE Temperature of Air on Condenser Coil Air on Evaporator Coil CFM 1800 2100 2400 2700 3000 1800 2100 2400 2700 3000 1800 2100 2400 2700 3000 WB (°F) 75°F Total Total2 Cap.1 Input (MBH) (kW) 85°F Sensible Capacity (MBH)* Return Dry Bulb (°F) 86 83 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 84.4 76.3 69.0 67.6 87.4 79.0 71.4 70.0 90.3 81.6 73.8 72.3 92.1 83.3 75.2 73.8 93.9 84.9 76.7 75.2 4.8 4.6 4.5 4.4 4.8 4.6 4.5 4.5 4.8 4.6 4.5 4.5 4.8 4.7 4.5 4.5 4.8 4.7 4.5 4.5 45.5 55.3 66.0 67.6 48.7 59.0 69.9 70.0 51.8 62.7 73.8 72.3 55.0 66.5 75.2 73.8 58.1 70.2 76.7 75.2 41.9 51.7 62.4 67.6 44.6 54.9 66.2 70.0 47.2 58.1 70.0 72.3 49.9 61.4 73.3 73.8 52.6 64.7 76.7 75.2 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 75.3 69.4 62.1 61.7 77.6 71.5 64.0 63.6 79.9 73.6 65.9 65.5 81.0 74.6 66.8 66.4 82.0 75.6 67.7 67.3 5.8 5.6 5.5 5.5 5.8 5.7 5.6 5.5 5.8 5.7 5.6 5.6 5.8 5.7 5.6 5.6 5.8 5.7 5.6 5.6 41.6 52.0 61.8 61.7 44.4 55.4 63.9 63.6 47.3 58.8 65.9 65.5 50.0 62.0 66.8 66.4 52.7 65.3 67.7 67.3 38.0 48.4 58.2 61.7 40.4 51.4 61.7 63.6 42.8 54.3 65.2 65.5 45.0 57.1 66.4 66.4 47.3 59.8 67.7 67.3 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 65.4 60.3 53.6 53.9 68.1 62.7 55.7 56.0 70.7 65.1 57.9 58.2 70.8 65.2 58.0 58.3 70.9 65.3 58.1 58.4 7.2 7.0 6.9 6.9 7.2 7.0 6.9 6.9 7.2 7.0 6.9 6.9 7.2 7.1 7.0 6.9 7.3 7.1 7.0 7.0 38.2 48.5 53.6 53.9 40.8 51.7 55.7 56.0 43.4 54.9 57.9 58.2 45.8 57.7 58.0 58.3 48.1 60.6 58.1 58.4 34.6 45.0 53.6 53.9 36.7 47.6 55.7 56.0 38.9 50.3 57.9 58.2 40.8 52.7 58.0 58.3 42.7 55.1 58.1 58.4 80 38.3 48.1 58.7 63.7 40.4 50.8 62.0 67.3 42.6 53.5 65.3 70.8 44.8 56.3 68.8 73.0 47.1 59.2 72.3 75.2 95°F 34.5 44.9 54.7 58.7 36.4 47.3 57.7 61.9 38.3 49.8 60.7 65.0 40.1 52.1 63.5 66.2 41.8 54.4 66.3 67.3 115°F 31.1 41.4 50.7 53.2 32.7 43.6 53.3 56.0 34.3 45.7 55.9 58.7 35.8 47.7 57.0 58.6 37.2 49.6 58.1 58.4 Total Total† Cap.* Input (MBH) (kW) Sensible Capacity (MBH)* Return Dry Bulb (°F) 77 74 71 68 86 83 34.6 44.4 55.1 60.1 36.3 46.6 57.9 63.1 37.9 48.8 60.7 66.2 39.8 51.3 63.8 68.0 41.6 53.7 66.8 69.7 31.0 40.8 51.5 56.4 32.2 42.5 53.8 59.0 33.3 44.2 56.1 61.6 34.7 46.2 58.7 62.9 36.1 48.2 61.3 64.2 37.2 47.9 52.8 38.4 49.7 54.9 39.6 51.4 56.9 41.1 53.6 57.8 42.7 55.8 58.7 33.6 44.2 49.2 34.3 45.5 50.7 34.9 46.8 52.3 36.1 48.6 52.7 37.2 50.3 53.2 79.9 72.8 65.5 64.7 82.5 75.2 67.7 66.8 85.1 77.6 69.8 68.9 86.5 78.9 71.0 70.1 88.0 80.2 72.2 71.2 5.3 5.1 5.0 5.0 5.3 5.1 5.0 5.0 5.3 5.2 5.0 5.0 5.3 5.2 5.1 5.0 5.3 5.2 5.1 5.1 43.6 53.6 63.9 64.7 46.6 57.2 66.9 66.8 49.6 60.8 69.8 68.9 52.5 64.3 71.0 70.1 55.4 67.7 72.2 71.2 40.0 50.1 60.3 64.7 42.5 53.1 63.9 66.8 45.0 56.2 67.6 68.9 47.5 59.2 69.9 70.1 49.9 62.3 72.2 71.2 31.0 41.3 51.2 55.1 32.4 43.3 53.7 57.8 33.7 45.3 56.1 60.5 35.1 47.1 58.5 61.2 36.4 49.0 60.9 61.8 27.4 37.8 47.6 51.6 28.3 39.3 49.6 53.8 29.2 40.7 51.6 56.0 30.1 42.2 53.6 56.2 31.0 43.6 55.5 56.4 34.3 44.1 48.0 35.2 45.6 49.8 36.2 47.1 51.5 37.2 48.6 51.3 38.2 50.1 51.0 30.7 40.6 44.5 31.2 41.6 45.7 31.7 42.6 47.0 32.2 43.6 46.3 32.8 44.7 45.6 70.4 64.8 57.9 57.8 72.8 67.1 59.9 59.8 75.3 69.4 61.9 61.9 75.9 69.9 62.4 62.3 76.5 70.5 62.9 62.8 6.5 6.3 6.2 6.2 6.5 6.3 6.2 6.2 6.5 6.3 6.2 6.2 6.5 6.4 6.3 6.3 6.6 6.4 6.3 6.3 39.9 50.2 57.7 57.8 42.6 53.5 59.8 59.8 45.4 56.8 61.9 61.9 47.9 59.9 62.4 62.3 50.4 62.9 62.9 62.8 36.3 46.7 55.9 57.8 38.6 49.5 58.7 59.8 40.8 52.3 61.5 61.9 42.9 54.9 62.2 62.3 45.0 57.5 62.9 62.8 27.5 37.8 47.1 49.6 28.6 39.5 49.2 51.9 29.7 41.1 51.3 54.2 30.7 42.7 52.0 53.5 31.8 44.2 52.6 52.9 23.9 34.3 43.5 46.1 24.5 35.4 45.1 47.8 25.1 36.6 46.8 49.6 25.7 37.7 47.0 48.5 26.3 38.7 47.2 47.5 30.7 40.0 42.5 31.4 41.1 43.8 32.0 42.2 45.0 32.6 41.9 43.5 33.3 41.7 42.0 27.2 36.4 38.9 27.3 37.0 39.7 27.4 37.6 40.4 27.6 36.9 38.5 27.8 36.2 36.6 60.5 55.7 49.3 50.0 63.3 58.3 51.6 52.3 66.1 60.9 53.9 54.6 65.7 60.5 53.6 54.3 65.4 60.2 53.2 53.9 7.9 7.7 7.6 7.6 7.9 7.7 7.6 7.6 7.9 7.6 7.6 7.6 7.9 7.7 7.6 7.6 8.0 7.8 7.7 7.7 36.5 46.8 49.3 50.0 39.0 49.9 51.6 52.3 41.5 52.9 53.9 54.6 43.7 55.6 53.6 54.3 45.9 58.2 53.2 53.9 32.9 43.3 49.3 50.0 34.9 45.8 51.6 52.3 36.9 48.3 53.9 54.6 38.7 50.5 53.6 54.3 40.4 52.7 53.2 53.9 80 36.4 46.5 56.7 61.2 38.4 49.1 59.9 64.6 40.4 51.6 63.0 67.9 42.5 54.2 66.2 69.6 44.5 56.8 69.3 71.2 105°F 32.8 43.1 52.7 55.9 34.5 45.4 55.5 58.9 36.3 47.7 58.3 61.9 37.9 49.9 60.2 62.4 39.5 52.0 62.2 62.8 125°F 29.3 39.7 48.6 50.0 30.8 41.7 51.1 52.3 32.3 43.7 53.6 54.6 33.6 45.5 53.6 54.3 34.9 47.3 53.2 53.9 77 74 71 68 32.8 42.9 53.1 57.6 34.3 45.0 55.8 60.5 35.8 47.0 58.4 63.4 37.4 49.2 61.2 64.6 39.0 51.4 63.9 65.8 29.2 39.3 49.6 54.0 30.2 40.9 51.7 56.4 31.3 42.5 53.9 58.8 32.4 44.2 56.1 59.6 33.6 45.9 58.4 60.3 35.7 46.0 50.4 36.8 47.6 52.3 37.9 49.3 54.2 39.2 51.1 54.5 40.4 53.0 54.9 32.2 42.4 46.8 32.7 43.5 48.2 33.3 44.7 49.6 34.1 46.1 49.5 35.0 47.5 49.4 29.2 39.6 49.1 52.4 30.5 41.4 51.4 54.9 31.7 43.2 53.7 57.3 32.9 44.9 55.3 57.4 34.1 46.6 56.8 57.4 25.7 36.0 45.6 48.8 26.4 37.3 47.4 50.8 27.2 38.7 49.2 52.8 27.9 39.9 50.3 52.4 28.7 41.2 51.3 52.0 32.5 42.0 45.3 33.3 43.3 46.8 34.1 44.7 48.2 34.9 45.3 47.4 35.7 45.9 46.5 28.9 38.5 41.7 29.3 39.3 42.7 29.6 40.1 43.7 29.9 40.3 42.4 30.3 40.5 41.1 25.8 36.1 45.0 46.9 26.7 37.6 47.0 48.9 27.7 39.1 49.0 51.0 28.6 40.4 48.7 49.7 29.5 41.8 48.4 48.5 22.2 32.5 41.5 43.3 22.6 33.5 42.9 44.8 23.1 34.5 44.3 46.4 23.5 35.4 43.7 44.7 24.0 36.3 43.0 43.0 28.9 37.9 39.7 29.4 38.8 40.7 29.9 39.7 41.8 30.3 38.6 39.6 30.8 37.5 37.5 25.4 34.3 36.2 25.3 34.7 36.7 25.3 35.1 37.2 25.3 33.6 34.6 25.3 32.0 32.0 1. The capacities are gross ratings. For net capacity, deduct indoor blower motor, MBH=3.415 x kW. Refer to the appropriate Blower Performance table for the kW of the supply air blower motor. 2. These ratings include the condensate fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. Unitary Products Group 29 036-21685-002-A-1105 TABLE 23: DR072 COOLING CAPACITIES (6 TON) - REHEAT MODE Temperature of Air on Condenser Coil Air on Evaporator Coil 75°F CFM 1800 2100 2400 2700 3000 1800 2100 2400 2700 3000 1800 2100 2400 2700 3000 WB (°F) Total Total Cap.1 Input (MBH) (kW) 85°F * 2 Sensible Capacity (MBH) Return Dry Bulb (°F) 86 83 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 57.6 53.4 47.4 44.6 61.1 56.7 50.3 47.3 64.6 60.0 53.2 50.0 65.5 60.8 54.0 50.7 66.4 61.6 54.7 51.4 4.3 4.2 4.2 4.1 4.3 4.3 4.2 4.1 4.4 4.3 4.2 4.1 4.4 4.3 4.2 4.1 4.4 4.3 4.3 4.2 27.1 33.2 37.8 41.0 29.0 35.6 40.5 43.9 31.0 37.9 43.2 46.9 31.6 38.7 44.0 47.7 32.3 39.4 44.7 48.5 25.6 31.8 36.4 39.6 27.4 34.0 38.9 42.4 29.2 36.2 41.4 45.1 29.7 36.8 42.0 45.8 30.2 37.3 42.7 46.4 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 53.0 48.7 44.4 34.2 56.1 51.6 47.0 36.2 59.2 54.5 49.6 38.2 60.1 55.2 50.3 38.8 60.9 56.0 51.0 39.3 5.4 5.3 5.2 5.1 5.5 5.4 5.2 5.1 5.5 5.4 5.3 5.2 5.5 5.4 5.3 5.2 5.6 5.5 5.3 5.2 24.3 30.3 35.0 32.6 26.0 32.5 37.5 35.0 27.7 34.7 40.0 37.3 28.3 35.2 40.6 37.9 28.8 35.8 41.2 38.5 22.8 28.9 33.6 31.2 24.5 30.9 35.9 33.4 26.1 33.0 38.3 35.6 26.4 33.4 38.7 36.0 26.8 33.8 39.1 36.4 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 47.7 43.8 38.7 36.6 50.3 46.3 40.9 38.7 53.0 48.7 43.0 40.7 53.4 49.2 43.4 41.1 53.9 49.6 43.8 41.4 6.7 6.6 6.4 6.2 6.7 6.7 6.5 6.3 6.8 6.8 6.6 6.4 6.8 6.7 6.6 6.4 6.8 6.7 6.5 6.4 21.0 27.3 31.5 36.6 22.5 29.3 33.8 38.7 24.1 31.3 36.1 40.7 24.4 31.6 36.5 41.1 24.8 32.0 36.8 41.4 19.6 25.9 30.1 35.5 21.1 27.8 32.3 38.0 22.5 29.7 34.5 40.6 22.6 29.8 34.7 40.7 22.8 30.0 34.8 40.8 80 24.2 30.3 34.9 38.2 25.9 32.4 37.3 40.8 27.5 34.5 39.7 43.4 27.8 34.9 40.1 43.8 28.1 35.2 40.6 44.3 95°F 21.4 27.5 32.2 29.8 22.9 29.4 34.4 31.9 24.4 31.3 36.6 33.9 24.5 31.5 36.8 34.1 24.7 31.7 37.1 34.4 115°F 18.3 24.6 28.8 34.1 19.6 26.3 30.9 36.6 20.9 28.1 32.9 39.0 20.8 28.0 32.9 38.9 20.8 28.0 32.8 38.8 Sensible Capacity (MBH)* Return Dry Bulb (°F) † Total Total Cap.* Input (MBH) (kW) 77 74 71 68 86 83 22.8 28.9 33.5 36.8 24.3 30.8 35.7 39.2 25.8 32.7 37.9 41.6 25.9 32.9 38.2 41.9 26.0 33.1 38.5 42.2 21.4 27.5 32.1 35.3 22.7 29.2 34.1 37.6 24.0 31.0 36.2 39.9 24.0 31.0 36.3 40.0 23.9 31.0 36.4 40.1 26.1 30.7 33.9 27.7 32.6 36.0 29.3 34.5 38.2 29.1 34.4 38.1 29.0 34.3 38.0 24.6 29.2 32.5 26.1 31.0 34.5 27.5 32.7 36.4 27.2 32.5 36.2 26.9 32.2 35.9 55.3 51.1 45.9 39.4 58.6 54.1 48.7 41.8 61.9 57.2 51.4 44.1 62.8 58.0 52.1 44.8 63.7 58.8 52.9 45.4 4.9 4.8 4.7 4.6 4.9 4.8 4.7 4.6 4.9 4.9 4.8 4.7 5.0 4.9 4.8 4.7 5.0 4.9 4.8 4.7 25.7 31.8 36.4 36.8 27.5 34.0 39.0 39.4 29.4 36.3 41.6 42.1 30.0 37.0 42.3 42.8 30.6 37.6 43.0 43.5 24.2 30.3 35.0 35.4 25.9 32.5 37.4 37.9 27.7 34.6 39.9 40.4 28.1 35.1 40.4 40.9 28.5 35.5 40.9 41.4 20.0 26.1 30.7 28.4 21.4 27.9 32.8 30.3 22.7 29.6 34.9 32.3 22.7 29.6 35.0 32.3 22.6 29.6 35.0 32.3 18.6 24.7 29.3 27.0 19.8 26.3 31.3 28.8 21.1 28.0 33.3 30.6 20.8 27.8 33.1 30.4 20.6 27.6 33.0 30.2 23.2 27.9 25.6 24.8 29.8 27.2 26.3 31.6 28.9 25.9 31.2 28.6 25.5 30.9 28.2 21.8 26.5 24.1 23.2 28.2 25.7 24.6 29.9 27.2 24.0 29.4 26.7 23.5 28.8 26.1 50.3 46.3 41.6 35.4 53.2 49.0 43.9 37.4 56.1 51.6 46.3 39.5 56.8 52.2 46.9 39.9 57.4 52.8 47.4 40.4 6.0 5.9 5.8 5.7 6.1 6.0 5.9 5.7 6.2 6.1 5.9 5.8 6.2 6.1 5.9 5.8 6.2 6.1 5.9 5.8 22.6 28.8 33.2 34.6 24.3 30.9 35.6 36.8 25.9 33.0 38.0 39.0 26.4 33.4 38.5 39.5 26.8 33.9 39.0 39.9 21.2 27.4 31.9 33.3 22.8 29.4 34.1 35.7 24.3 31.3 36.4 38.1 24.5 31.6 36.7 38.4 24.8 31.9 37.0 38.6 16.9 23.2 27.4 32.8 18.1 24.8 29.4 35.1 19.3 26.5 31.3 37.4 19.0 26.2 31.0 37.1 18.8 26.0 30.8 36.8 15.5 21.8 26.1 31.4 16.6 23.4 27.9 33.6 17.7 24.9 29.7 35.8 17.2 24.4 29.2 35.3 16.8 24.0 28.8 34.8 20.5 24.7 30.0 21.9 26.4 32.1 23.3 28.1 34.2 22.6 27.4 33.5 22.0 26.8 32.8 19.1 23.4 28.7 20.4 24.9 30.6 21.7 26.5 32.6 20.8 25.6 31.7 20.0 24.8 30.8 45.0 41.4 35.9 37.8 47.5 43.6 37.8 39.9 49.9 45.9 39.7 42.0 50.1 46.1 39.9 42.2 50.4 46.3 40.1 42.5 7.3 7.3 7.0 6.8 7.4 7.3 7.1 6.9 7.5 7.4 7.2 7.0 7.4 7.4 7.2 7.0 7.4 7.4 7.1 6.9 19.3 25.7 29.8 37.8 20.8 27.7 32.0 39.9 22.3 29.6 34.2 42.0 22.5 29.8 34.4 42.2 22.8 30.0 34.6 42.5 18.0 24.4 28.4 37.6 19.4 26.2 30.5 39.9 20.7 28.0 32.6 42.0 20.8 28.0 32.6 42.2 20.8 28.0 32.6 42.5 80 22.8 28.9 33.5 34.0 24.4 30.9 35.8 36.3 25.9 32.9 38.2 38.7 26.2 33.2 38.5 39.0 26.4 33.5 38.8 39.3 105°F 19.8 26.0 30.5 32.0 21.2 27.9 32.6 34.2 22.6 29.7 34.8 36.5 22.7 29.8 34.8 36.5 22.7 29.8 34.9 36.6 125°F 16.7 23.1 27.1 36.3 17.9 24.8 29.1 38.9 19.1 26.5 31.1 41.6 19.0 26.3 30.9 41.3 18.8 26.1 30.6 41.1 77 74 71 68 21.4 27.5 32.1 32.6 22.8 29.3 34.3 34.8 24.2 31.2 36.4 37.0 24.3 31.3 36.6 37.1 24.3 31.4 36.7 37.3 20.0 26.1 30.7 31.1 21.3 27.8 32.7 33.2 22.5 29.5 34.7 35.2 22.4 29.4 34.7 35.2 22.2 29.3 34.7 35.2 24.7 29.3 29.7 26.2 31.2 31.6 27.8 33.0 33.5 27.5 32.8 33.3 27.2 32.6 33.1 23.2 27.9 28.3 24.7 29.6 30.1 26.1 31.3 31.8 25.6 30.9 31.4 25.2 30.5 31.0 18.5 24.6 29.1 30.6 19.7 26.3 31.1 32.7 21.0 28.1 33.1 34.8 20.9 27.9 33.0 34.7 20.7 27.8 32.9 34.6 17.1 23.3 27.7 29.2 18.2 24.8 29.6 31.2 19.4 26.4 31.5 33.2 19.0 26.1 31.2 32.9 18.7 25.8 30.9 32.5 21.9 26.3 27.8 23.3 28.1 29.7 24.8 29.9 31.6 24.3 29.3 31.0 23.7 28.8 30.5 20.5 24.9 26.4 21.8 26.6 28.2 23.1 28.2 29.9 22.4 27.5 29.2 21.7 26.8 28.5 15.4 21.8 25.8 34.9 16.5 23.3 27.6 37.5 17.6 24.9 29.5 40.0 17.2 24.5 29.1 39.6 16.9 24.1 28.7 39.1 14.0 20.4 24.5 33.6 15.0 21.9 26.2 36.0 16.0 23.3 27.9 38.4 15.4 22.7 27.3 37.8 14.9 22.1 26.7 37.1 19.1 23.1 32.3 20.4 24.7 34.6 21.8 26.4 36.8 21.0 25.5 36.0 20.2 24.7 35.2 17.8 21.8 31.0 19.0 23.3 33.1 20.2 24.8 35.3 19.2 23.8 34.2 18.2 22.8 33.2 1. The capacities are gross ratings. For net capacity, deduct indoor blower motor, MBH=3.415 x kW. Refer to the appropriate Blower Performance table for the kW of the supply air blower motor. 2. These ratings include the condensate fan motors (total 1 kW) and the compressor motors but not the supply air blower motor. 30 Unitary Products Group 036-21685-002-A-1105 DR036 Moisture Removal @ 1200 cfm Reheat Mode @ Various Indoor (dry bulb / wet bulb) Conditions Moisture Removal Rate (lbs Water/Hour) 25 20 15 10 5 0 65 75 85 Outdoor Temperature (ºF) 95 75db/71wb 80db/71wb 75db/67wb 85db/71wb 80db/67wb 85db/67wb 105 FIGURE 2 - DR036 MOISTURE REMOVAL - REHEAT MODE DR048 Moisture Removal @ 1600 cfm Reheat Mode @ Various Indoor (dry bulb / wet bulb) Conditions Moisture Removal Rate (lbs Water/Hour) 30 25 20 15 10 5 0 65 75 85 Outdoor Temperature (ºF) 95 75db/71wb 80db/71wb 75db/67wb 85db/71wb 80db/67wb 85db/67wb 105 FIGURE 3 - DR048 MOISTURE REMOVAL - REHEAT MODE Unitary Products Group 31 036-21685-002-A-1105 DR060 Moisture Removal @ 2000 cfm Reheat Mode @ Various Indoor (dry bulb / wet bulb) Conditions 35 Moisture Removal Rate (lbs Water/Hour) 30 25 20 15 10 5 0 65 75 85 Outdoor Temperature (ºF) 95 75db/71wb 80db/71wb 75db/67wb 85db/71wb 80db/67wb 85db/67wb 105 FIGURE 4 - DR060 MOISTURE REMOVAL - REHEAT MODE DR072 Moisture Removal @ 2400 cfm Reheat Mode @ Various Indoor (dry bulb / wet bulb) Conditions 40 Moisture Removal Rate (lbs Water/Hour) 35 30 25 20 15 10 5 0 65 75 85 Outdoor Temperature (ºF) 95 75db/71wb 80db/71wb 75db/67wb 85db/71wb 80db/67wb 85db/67wb 105 FIGURE 5 - DR072 MOISTURE REMOVAL - REHEAT MODE 32 Unitary Products Group 036-21685-002-A-1105 TABLE 24: SUPPLY AIR BLOWER PERFORMANCE (DR036 BELT DRIVE) - SIDE DUCT APPLICATION AVAILABLE EXTERNAL STATIC PRESSURE - IWG1 AIR FLOW CFM RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS 800 ---- ---- ---- ---- ---- ---- 696 357 0.38 743 389 0.42 786 422 0.45 900 ---- ---- ---- 656 353 0.38 706 385 0.41 753 417 0.45 797 450 0.48 1000 ---- ---- ---- 671 376 0.40 722 408 0.44 768 440 0.47 812 473 0.51 0.2 0.3 0.4 0.5 0.6 BHP 1100 634 364 0.39 690 398 0.43 741 431 0.46 787 463 0.50 831 496 0.53 1200 656 389 0.42 712 423 0.45 763 455 0.49 809 488 0.52 853 520 0.56 1300 681 418 0.45 737 452 0.49 787 485 0.52 834 517 0.55 877 550 0.59 1400 707 454 0.49 763 488 0.52 813 520 0.56 860 552 0.59 903 585 0.63 1500 735 496 0.53 791 530 0.57 841 562 0.60 887 594 0.64 931 627 0.67 1600 763 545 0.58 819 579 0.62 870 612 0.66 916 644 0.69 960 677 0.73 1700 793 602 0.65 849 636 0.68 900 669 0.72 946 701 0.75 990 734 0.79 1800 824 667 0.72 880 701 0.75 930 733 0.79 977 765 0.82 1021 798 0.86 1900 855 739 0.79 911 773 0.83 962 806 0.86 1008 838 0.90 1052 871 0.93 2000 887 819 0.88 943 853 0.92 994 886 0.95 1040 918 0.98 1084 951 1.02 AVAILABLE EXTERNAL STATIC PRESSURE - IWG1 AIR FLOW CFM RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP 800 829 457 0.49 872 495 0.53 916 538 0.58 964 586 0.63 1017 642 0.69 900 839 485 0.52 882 524 0.56 927 566 0.61 975 615 0.66 1027 670 0.72 1000 854 508 0.55 897 547 0.59 942 589 0.63 990 638 0.68 1043 693 0.74 1100 874 531 0.57 916 569 0.61 961 612 0.66 1009 660 0.71 1062 715 0.77 1200 896 555 0.60 938 594 0.64 983 636 0.68 1031 685 0.73 1084 740 0.79 1300 920 585 0.63 963 623 0.67 1007 666 0.71 1055 714 0.77 1108 770 0.83 1400 946 620 0.67 989 659 0.71 1034 701 0.75 1082 750 0.80 ---- ---- ---- 1500 974 662 0.71 1017 701 0.75 1061 743 0.80 1109 792 0.85 ---- ---- ---- 1600 1003 712 0.76 1045 750 0.80 1090 793 0.85 ---- ---- ---- ---- ---- ---- 1700 1032 769 0.82 1075 807 0.87 ---- ---- ---- ---- ---- ---- ---- ---- ---- 1800 1063 833 0.89 1106 872 0.94 ---- ---- ---- ---- ---- ---- ---- ---- ---- 1900 1094 906 0.97 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2000 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 0.7 0.8 0.9 1.0 1.1 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. Factory Installed AK74 blower sheave and A39 belt. AK61 blower sheave and A36 belt - Field installation required. Unitary Products Group 33 036-21685-002-A-1105 TABLE 25: SUPPLY AIR BLOWER PERFORMANCE (DR036 BELT DRIVE) - BOTTOM DUCT APPLICATION AVAILABLE EXTERNAL STATIC PRESSURE - IWG1 AIR FLOW CFM RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS 800 ---- ---- ---- ---- ---- ---- ---- ---- ---- 749 384 0.41 791 422 0.45 900 ---- ---- ---- ---- ---- ---- 720 364 0.39 764 404 0.43 806 443 0.47 1000 ---- ---- ---- 690 346 0.37 739 388 0.42 783 429 0.46 824 467 0.50 1100 657 334 0.36 711 376 0.40 760 417 0.45 804 458 0.49 845 497 0.53 1200 681 369 0.40 735 410 0.44 784 452 0.49 828 493 0.53 869 532 0.57 0.2 0.3 0.4 0.5 0.6 BHP 1300 707 409 0.44 761 451 0.48 809 493 0.53 854 534 0.57 895 572 0.61 1400 735 456 0.49 789 498 0.53 837 540 0.58 882 581 0.62 923 619 0.66 1500 765 509 0.55 819 550 0.59 867 592 0.64 911 633 0.68 953 672 0.72 1600 796 567 0.61 850 609 0.65 899 651 0.70 943 692 0.74 984 730 0.78 1700 829 631 0.68 883 673 0.72 932 715 0.77 976 756 0.81 1017 794 0.85 1800 863 701 0.75 918 743 0.80 966 785 0.84 1010 826 0.89 1051 864 0.93 1900 899 776 0.83 953 818 0.88 1001 860 0.92 1045 901 0.97 1087 939 1.01 2000 936 857 0.92 990 899 0.96 1038 941 1.01 1082 981 1.05 ---- ---- ---- AVAILABLE EXTERNAL STATIC PRESSURE - IWG1 AIR FLOW CFM RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP 800 831 456 0.49 871 486 0.52 914 509 0.55 961 525 0.56 1012 532 0.57 900 846 477 0.51 886 507 0.54 929 530 0.57 976 546 0.59 1027 553 0.59 1000 864 502 0.54 905 531 0.57 947 555 0.60 994 571 0.61 1046 578 0.62 1100 885 531 0.57 926 561 0.60 969 584 0.63 1015 600 0.64 1067 607 0.65 1200 909 566 0.61 950 596 0.64 992 619 0.66 1039 635 0.68 1091 642 0.69 1300 935 607 0.65 976 636 0.68 1018 660 0.71 1065 676 0.72 ---- ---- ---- 1400 963 654 0.70 1004 683 0.73 1046 707 0.76 1093 722 0.77 ---- ---- ---- 1500 993 706 0.76 1033 736 0.79 1076 759 0.81 ---- ---- ---- ---- ---- ---- 1600 1024 765 0.82 1065 794 0.85 1108 818 0.88 ---- ---- ---- ---- ---- ---- 1700 1057 829 0.89 1098 859 0.92 ---- ---- ---- ---- ---- ---- ---- ---- ---- 1800 1091 899 0.96 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1900 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2000 0.7 0.8 0.9 1.0 1.1 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. Factory Installed AK74 blower sheave and A39 belt. AK61 blower sheave and A36 belt - Field installation required. 34 Unitary Products Group 036-21685-002-A-1105 TABLE 26: SUPPLY AIR BLOWER PERFORMANCE (DR048 BELT DRIVE) - SIDE DUCT APPLICATION AVAILABLE EXTERNAL STATIC PRESSURE - IWG1 AIR FLOW 0.2 0.3 0.4 0.5 0.6 0.7 CFM RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP 1000 ---- ---- ---- ---- ---- ---- ---- ---- ---- 789 527 0.57 831 567 0.61 874 602 1100 ---- ---- ---- ---- ---- ---- ---- ---- ---- 811 559 0.60 854 599 0.64 896 634 0.65 0.68 1200 ---- ---- ---- ---- ---- ---- 791 548 0.59 833 592 0.63 876 632 0.68 918 667 0.72 1300 ---- ---- ---- 772 539 0.58 813 584 0.63 855 628 0.67 898 668 0.72 940 703 0.75 1400 ---- ---- ---- 795 579 0.62 836 624 0.67 878 668 0.72 920 708 0.76 963 744 0.80 1500 779 578 0.62 819 624 0.67 860 669 0.72 902 713 0.77 944 753 0.81 987 789 0.85 1600 804 629 0.67 844 675 0.72 885 720 0.77 927 764 0.82 970 804 0.86 1013 839 0.90 1700 831 685 0.74 871 731 0.78 913 777 0.83 955 820 0.88 997 861 0.92 1040 896 0.96 1800 860 748 0.80 901 794 0.85 942 839 0.90 984 883 0.95 1026 923 0.99 1069 958 1.03 1900 891 817 0.88 931 862 0.92 973 908 0.97 1015 951 1.02 1057 992 1.06 1100 1027 1.10 2000 924 891 0.96 964 937 1.01 1005 982 1.05 1047 1026 1.10 1090 1066 1.14 1133 1102 1.18 2100 959 972 1.04 999 1018 1.09 1040 1063 1.14 1082 1107 1.19 1125 1147 1.23 1167 1182 1.27 2200 996 1059 1.14 1036 1104 1.18 1077 1150 1.23 1119 1194 1.28 1162 1234 1.32 ---- ---- ---- 2300 1034 1151 1.24 1075 1197 1.28 1116 1243 1.33 1158 1286 1.38 ---- ---- ---- ---- ---- ---- 2400 1075 1250 1.34 1115 1296 1.39 1156 1341 1.44 ---- ---- ---- ---- ---- ---- ---- ---- ---- 2500 1118 1354 1.45 1158 1400 1.50 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- AVAILABLE EXTERNAL STATIC PRESSURE - IWG1 AIR FLOW 0.8 0.9 1.0 1.1 1.2 1.3 CFM RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP 1000 917 631 0.68 959 651 0.70 1001 660 0.71 1041 658 0.71 1081 642 0.69 1119 611 0.66 1100 939 663 0.71 981 683 0.73 1023 692 0.74 1064 690 0.74 1103 674 0.72 1141 643 0.69 1200 961 696 0.75 1003 716 0.77 1045 725 0.78 1086 723 0.78 1125 707 0.76 1163 676 0.73 1300 983 732 0.79 1025 752 0.81 1067 761 0.82 1108 759 0.81 1147 743 0.80 1185 712 0.76 1400 1006 772 0.83 1048 792 0.85 1090 801 0.86 1130 799 0.86 1170 783 0.84 ---- ---- ---- 1500 1030 817 0.88 1072 837 0.90 1114 847 0.91 1154 844 0.91 1194 829 0.89 ---- ---- ---- 1600 1055 868 0.93 1098 888 0.95 1139 897 0.96 1180 895 0.96 ---- ---- ---- ---- ---- ---- 1700 1083 924 0.99 1125 944 1.01 1166 954 1.02 ---- ---- ---- ---- ---- ---- ---- ---- ---- 1800 1112 987 1.06 1154 1007 1.08 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1900 1142 1055 1.13 1185 1075 1.15 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2000 1175 1130 1.21 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2100 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2200 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2300 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2400 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2500 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. Factory Installed AK61 blower sheave and A36 belt. AK56 blower sheave and A36 belt - Field installation required. Unitary Products Group 35 036-21685-002-A-1105 TABLE 27: SUPPLY AIR BLOWER PERFORMANCE (DR048 BELT DRIVE) - BOTTOM DUCT APPLICATION AVAILABLE EXTERNAL STATIC PRESSURE - IWG1 AIR FLOW 0.2 0.3 0.4 0.5 0.6 0.7 CFM RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP 1000 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 833 564 0.61 879 605 0.65 1100 ---- ---- ---- ---- ---- ---- ---- ---- ---- 809 549 0.59 854 592 0.63 900 633 0.68 1200 ---- ---- ---- ---- ---- ---- 786 538 0.58 830 581 0.62 875 623 0.67 920 664 0.71 1300 ---- ---- ---- 766 535 0.57 808 574 0.62 851 617 0.66 896 659 0.71 942 700 0.75 1400 749 541 0.58 789 576 0.62 830 616 0.66 874 658 0.71 918 701 0.75 964 742 0.80 1500 774 587 0.63 813 622 0.67 855 662 0.71 898 705 0.76 943 747 0.80 989 788 0.85 1600 801 639 0.69 840 674 0.72 881 714 0.77 925 757 0.81 970 799 0.86 1015 840 0.90 1700 830 697 0.75 869 732 0.79 911 772 0.83 954 814 0.87 999 857 0.92 1045 898 0.96 1800 862 760 0.81 901 795 0.85 943 835 0.90 986 877 0.94 1031 920 0.99 1077 960 1.03 1900 897 828 0.89 936 863 0.93 977 903 0.97 1021 945 1.01 1066 988 1.06 1111 1029 1.10 2000 934 901 0.97 973 936 1.00 1015 976 1.05 1058 1018 1.09 1103 1061 1.14 1149 1102 1.18 1180 1.27 2100 974 979 1.05 1013 1014 1.09 1055 1054 1.13 1098 1097 1.18 1143 1139 1.22 1189 2200 1017 1063 1.14 1056 1098 1.18 1098 1138 1.22 1141 1180 1.27 1186 1223 1.31 ---- ---- ---- 2300 1063 1151 1.23 1102 1186 1.27 1144 1226 1.31 1187 1268 1.36 ---- ---- ---- ---- ---- ---- 2400 1111 1243 1.33 1151 1278 1.37 1192 1318 1.41 ---- ---- ---- ---- ---- ---- ---- ---- ---- 2500 1163 1340 1.44 1202 1376 1.48 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- AVAILABLE EXTERNAL STATIC PRESSURE - IWG1 AIR FLOW 0.8 0.9 1.0 1.1 1.2 1.3 CFM RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP 1000 925 642 0.69 971 673 0.72 1017 696 0.75 1061 708 0.76 1103 708 0.76 1144 693 0.74 1100 946 670 0.72 992 701 0.75 1037 723 0.78 1082 736 0.79 1124 735 0.79 1165 721 0.77 1200 967 701 0.75 1013 732 0.79 1058 755 0.81 1102 767 0.82 1145 767 0.82 1185 752 0.81 ---- 1300 988 737 0.79 1034 768 0.82 1079 791 0.85 1123 803 0.86 1166 803 0.86 ---- ---- 1400 1010 779 0.84 1056 809 0.87 1102 832 0.89 1146 844 0.91 1188 844 0.91 ---- ---- ---- 1500 1035 825 0.89 1081 856 0.92 1126 879 0.94 1170 891 0.96 ---- ---- ---- ---- ---- ---- 1600 1062 877 0.94 1108 908 0.97 1153 931 1.00 1197 943 1.01 ---- ---- ---- ---- ---- ---- 1700 1091 935 1.00 1137 966 1.04 1182 988 1.06 ---- ---- ---- ---- ---- ---- ---- ---- ---- 1800 1123 997 1.07 1169 1028 1.10 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1900 1157 1066 1.14 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2000 1195 1139 1.22 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2100 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2200 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2300 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2400 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2500 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. Factory Installed AK61 blower sheave and A36 belt. AK56 blower sheave and A36 belt - Field installation required. 36 Unitary Products Group 036-21685-002-A-1105 TABLE 28: SUPPLY AIR BLOWER PERFORMANCE (DR060 & DR072 BELT DRIVE) - SIDE DUCT APPLICATION AVAILABLE EXTERNAL STATIC PRESSURE - IWG1 AIR FLOW 0.2 0.3 0.4 0.5 0.6 0.7 CFM RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP 1200 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 876 632 0.68 918 667 0.72 1300 ---- ---- ---- ---- ---- ---- ---- ---- ---- 855 628 0.67 898 668 0.72 940 703 0.75 1400 ---- ---- ---- ---- ---- ---- 836 624 0.67 878 668 0.72 920 708 0.76 963 744 0.80 1500 ---- ---- ---- 819 624 0.67 860 669 0.72 902 713 0.77 944 753 0.81 987 789 0.85 1600 ---- ---- ---- 844 675 0.72 885 720 0.77 927 764 0.82 970 804 0.86 1013 839 0.90 1700 831 685 0.74 871 731 0.78 913 777 0.83 955 820 0.88 997 861 0.92 1040 896 0.96 1800 860 748 0.80 901 794 0.85 942 839 0.90 984 883 0.95 1026 923 0.99 1069 958 1.03 1900 891 817 0.88 931 862 0.92 973 908 0.97 1015 951 1.02 1057 992 1.06 1100 1027 1.10 2000 924 891 0.96 964 937 1.01 1005 982 1.05 1047 1026 1.10 1090 1066 1.14 1133 1102 1.18 2100 959 972 1.04 999 1018 1.09 1040 1063 1.14 1082 1107 1.19 1125 1147 1.23 1167 1182 1.27 2200 996 1059 1.14 1036 1104 1.18 1077 1150 1.23 1119 1194 1.28 1162 1234 1.32 ---- ---- ---- 2300 1034 1151 1.24 1075 1197 1.28 1116 1243 1.33 1158 1286 1.38 ---- ---- ---- ---- ---- ---- 2400 1075 1250 1.34 1115 1296 1.39 1156 1341 1.44 ---- ---- ---- ---- ---- ---- ---- ---- ---- 2500 1118 1354 1.45 1158 1400 1.50 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- AVAILABLE EXTERNAL STATIC PRESSURE - IWG1 AIR 0.8 0.9 1.0 1.1 1.2 1.3 FLOW CFM RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP 1200 961 696 0.75 1003 716 0.77 1045 725 0.78 1086 723 0.78 1125 707 0.76 1163 676 0.73 1300 983 732 0.79 1025 752 0.81 1067 761 0.82 1108 759 0.81 1147 743 0.80 1185 712 0.76 1400 1006 772 0.83 1048 792 0.85 1090 801 0.86 1130 799 0.86 1170 783 0.84 ---- ---- ---- 1500 1030 817 0.88 1072 837 0.90 1114 847 0.91 1154 844 0.91 1194 829 0.89 ---- ---- ---- 1600 1055 868 0.93 1098 888 0.95 1139 897 0.96 1180 895 0.96 ---- ---- ---- ---- ---- ---- 1700 1083 924 0.99 1125 944 1.01 1166 954 1.02 ---- ---- ---- ---- ---- ---- ---- ---- ---- 1800 1112 987 1.06 1154 1007 1.08 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1900 1142 1055 1.13 1185 1075 1.15 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2000 1175 1130 1.21 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2100 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2200 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2300 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2400 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2500 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. Factory Installed AK56 blower sheave and A36 belt. Unitary Products Group 37 036-21685-002-A-1105 TABLE 29: SUPPLY AIR BLOWER PERFORMANCE (DR060 & DR072 BELT DRIVE) - BOTTOM DUCT APPLICATION AVAILABLE EXTERNAL STATIC PRESSURE - IWG1 AIR FLOW 0.2 0.3 0.4 0.5 0.6 0.7 CFM RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP 1000 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 862 453 0.49 901 498 1100 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 883 494 0.53 922 539 0.53 0.58 1200 ---- ---- ---- ---- ---- ---- ---- ---- ---- 866 489 0.53 904 536 0.58 943 581 0.62 1300 ---- ---- ---- ---- ---- ---- 850 488 0.52 889 535 0.57 928 581 0.62 967 627 0.67 1400 ---- ---- ---- 836 491 0.53 875 537 0.58 913 584 0.63 952 631 0.68 991 676 0.73 1500 ---- ---- ---- 862 545 0.58 901 591 0.63 940 638 0.68 978 685 0.73 1017 730 0.78 1600 851 559 0.60 890 604 0.65 928 650 0.70 967 697 0.75 1006 744 0.80 1045 789 0.85 1700 880 624 0.67 919 668 0.72 958 714 0.77 996 761 0.82 1035 808 0.87 1074 853 0.92 1800 911 694 0.74 949 738 0.79 988 785 0.84 1027 832 0.89 1066 878 0.94 1105 923 0.99 1900 942 770 0.83 981 814 0.87 1020 860 0.92 1059 907 0.97 1097 954 1.02 1136 999 1.07 2000 976 851 0.91 1014 895 0.96 1053 941 1.01 1092 989 1.06 1130 1035 1.11 1169 1080 1.16 2100 1010 938 1.01 1049 982 1.05 1087 1028 1.10 1126 1075 1.15 1165 1122 1.20 1204 1167 1.25 2200 1046 1030 1.11 1084 1075 1.15 1123 1121 1.20 1162 1168 1.25 1200 1215 1.30 ---- ---- ---- 2300 1082 1128 1.21 1121 1172 1.26 1160 1219 1.31 1198 1266 1.36 ---- ---- ---- ---- ---- ---- 2400 1120 1231 1.32 1159 1276 1.37 1198 1322 1.42 ---- ---- ---- ---- ---- ---- ---- ---- ---- 2500 1159 1340 1.44 1198 1384 1.48 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- AVAILABLE EXTERNAL STATIC PRESSURE - IWG1 AIR 0.8 0.9 1.0 1.1 1.2 1.3 FLOW CFM RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP RPM WATTS BHP 1000 940 541 0.58 980 579 0.62 1019 613 0.66 1059 641 0.69 1099 662 0.71 1140 674 1100 961 582 0.62 1000 621 0.67 1040 654 0.70 1080 682 0.73 1120 703 0.75 1161 715 0.72 0.77 1200 983 624 0.67 1022 663 0.71 1062 697 0.75 1101 725 0.78 1142 745 0.80 1182 758 0.81 1300 1006 669 0.72 1045 708 0.76 1085 742 0.80 1125 770 0.83 1165 791 0.85 ---- ---- ---- 1400 1030 718 0.77 1070 757 0.81 1109 791 0.85 1149 819 0.88 1190 840 0.90 ---- ---- ---- 1500 1057 772 0.83 1096 811 0.87 1136 845 0.91 1176 873 0.94 ---- ---- ---- ---- ---- ---- 1600 1084 831 0.89 1124 870 0.93 1163 904 0.97 1203 932 1.00 ---- ---- ---- ---- ---- ---- 1700 1113 896 0.96 1153 935 1.00 1192 969 1.04 ---- ---- ---- ---- ---- ---- ---- ---- ---- 1800 1144 966 1.04 1183 1005 1.08 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 1900 1175 1042 1.12 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2000 1209 1123 1.20 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2100 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2200 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2300 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2400 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- 2500 1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications. Factory Installed AK56 blower sheave and A36 belt. 38 Unitary Products Group 036-21685-002-A-1105 TABLE 30: BELT DRIVE BLOWER MOTOR AND DRIVE DATA MOTOR1 ADJUSTABLE MOTOR PULLEY BELT (NOTCHED) FIXED BLOWER PULLEY MODEL SIZE BLOWER RANGE (RPM) HP FRAME DESIGNATION OUTSIDE DIA. (IN.) PITCH DIA. (IN.) BORE (IN.) DESIGNATION OUTSIDE DIA. (IN.) PITCH DIA. (IN.) BORE (IN.) DESIGNATION PITCH LENGTH (IN.) QTY. 3 TON 790/1120 1 1/2 56 1VL40 2.7-3.7 2.4-3.4 7/8 AK74 7.25 7.2 1 A39 40.3 1 4 TON 790/1120 1 1/2 56 1VL40 2.7-3.7 2.4-3.4 7/8 AK61 5.9 5.7 1 A36 37.3 1 5, 6 TON 850/1220 1 1/2 56 1VL40 2.7-3.7 2.4-3.4 7/8 AK56 5.4 5.2 1 A35 36.3 1 1. All motors have solid bases and are inherently protected. these motors can be selected to operate into their service factor because they are located in the moving air, upstream of any heating device. TABLE 31: STATIC RESISTANCES RESISTANCE, IWG DESCRIPTION CFM 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 0.07 0.08 0.09 0.11 0.13 0.15 0.17 0.20 0.23 0.26 0.30 7-15KW 0.04 0.05 0.06 0.07 0.08 0.10 0.12 0.14 0.16 0.19 0.22 20-30KW 0.06 0.07 0.08 0.09 0.11 0.13 0.15 0.17 0.20 0.23 0.26 2 0.08 0.10 0.12 0.14 0.16 0.18 0.20 0.23 0.26 0.29 0.32 1,3 ECONOMIZER ELECTRIC HEATERS1 COOLING ONLY 1. Deduct these resistance values from the available external static pressure shown in SUPPLY AIR BLOWER PERFORMANCE Tables. 2. Add these resistance values to the available static resistance values on SUPPLY AIR BLOWER PERFORMANCE Tables. 3. The pressure through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct system is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. TABLE 32: ELECTRIC HEATER CFM LIMITATIONS MINIMUM SUPPLY AIR CFM UNITMODEL SIZE NOMINAL TONS VOLTAGE HEATER SIZE NOMINAL KW 5 7 10 15 20 30 208/230-1-60 1100 1100 1200 1200 1300 - 208/230-3-60 1100 1100 1200 1200 1300 - 460-3-60 - 1100 1200 1200 1300 - 575-3-60 - - 1200 1200 1300 - 208/230-1-60 1300 1300 1300 1300 1300 - 208/230-3-60 1300 1300 1300 1300 1300 - 460-3-60 - 1300 1300 1300 1300 - 575-3-60 - - 1300 1300 1400 - 208/230-1-60 1600 1600 1600 1600 1600 1600 208/230-3-60 1600 1600 1600 1600 1600 1600 460-3-60 1600 1600 1600 1600 1600 1600 575-3-60 - 1600 1600 1600 1600 1800 208/230-3-60 1800 1800 1800 1800 1800 1800 460-3-60 1800 1800 1800 1800 1800 1800 575-3-60 - - 1800 1800 1800 1800 3 4 5 6 Unitary Products Group 39 036-21685-002-A-1105 TABLE 33: ELECTRICAL DATA - DR036 AND DR048 W/O POWERED CONVENIENCE OUTLET COMPRESSORS MODEL TONNAGE VOLTAGE RLA EACH LRA EACH OD FAN MOTOR FLA ID BLOWER MOTOR FLA CONV OUTLET FLA 208-1-60 11.8 68.0 2.3 7.6 0.0 230-1-60 11.8 68.0 2.3 7.6 0.0 208-3-60 8.3 68 2.3 5.2 0.0 230-3-60 8.3 68 2.3 5.2 0.0 460-3-60 5.1 34 1.3 2.6 0.0 575-3-60 3.2 26.0 1.3 2.0 0.0 208-1-60 15.4 86.0 2.3 7.6 0.0 230-1-60 15.4 86.0 2.3 7.6 0.0 208-3-60 11.5 84 2.3 5.2 0.0 230-3-60 11.5 84 2.3 5.2 0.0 460-3-60 5.8 42 1.3 2.6 0.0 575-3-60 5.1 34 1.3 2 0.0 DR036 DR048 ELECTRIC HEATER HEATER HEATER MODEL NO. KW AMPS None 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 None 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 None 2CE045107462 2CE045110462 2CE045115462 2CE045120462 None 2CE04511058 2CE04511558 2CE04512058 None 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 None 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 None 2CE045107462 2CE045110462 2CE045115462 2CE045120462 None 2CE04511058 2CE04511558 2CE04512058 -4.0 5.6 8.0 11.9 15.9 -5.3 7.5 10.6 15.9 21.2 -4.0 5.6 8.0 11.9 15.9 -5.3 7.5 10.6 15.9 21.2 -6.8 10.1 13.6 19.5 -10.6 15.9 21.2 -4.0 5.6 8.0 11.9 15.9 -5.3 7.5 10.6 15.9 21.2 -4.0 5.6 8.0 11.9 15.9 -5.3 7.5 10.6 15.9 21.2 -6.8 10.1 13.6 19.5 -10.6 15.9 21.2 -19.2 26.9 38.5 57.2 76.4 -22.1 31.3 44.2 66.3 88.3 -11.1 15.5 22.2 33.0 44.1 -12.7 18.0 25.5 38.2 51.0 -8.2 12.1 16.4 23.5 -10.2 15.3 20.4 -19.2 26.9 38.5 57.2 76.4 -22.1 31.3 44.2 66.3 88.3 -11.1 15.5 22.2 33.0 44.1 -12.7 18.0 25.5 38.2 51.0 -8.2 12.1 16.4 23.5 -10.2 15.3 20.4 MIN. MAX. FUSE/ CIRCUIT BRKR1 SIZE AMPACITY (AMPS) (AMPS) 24.6 30 33.5 35 43.2 45 57.6 60 81.0 90 105.1 110 24.6 30 37.1 40 38.6 50 64.7 70 92.3 100 119.9 125 17.9 25 20.4 25 25.9 30 34.3 35 47.8 50 61.7 70 17.9 25 22.4 25 29.1 30 38.4 40 54.3 60 70.2 80 10.3 15 13.5 15 18.4 20 23.7 25 32.6 35 7.0 15 15.2 20 21.6 25 28.0 30 29.1 35 33.5 40 43.2 45 57.6 60 81.0 90 105.1 110 29.1 35 37.1 50 48.6 50 64.7 70 92.3 100 119.9 125 21.9 30 21.9 30 25.9 30 34.3 35 47.8 50 61.7 70 21.9 30 22.4 30 29.1 30 38.4 40 54.3 60 70.2 80 11.1 15 13.5 15 18.4 20 23.7 25 32.6 35 9.4 15 15.2 20 21.6 25 28.0 30 1. HACR Typer Per NEC. 2. These electric heaters DO NOT include a fuse box. If a fuse box is required to meet a local code (e.e. Chicago), the fuse block accessories 2FB04700825 and 2FB04700846 are available for field installation. 40 Unitary Products Group 036-21685-002-A-1105 TABLE 34: ELECTRICAL DATA - DR060 AND DR072 W/O POWERED CONVENIENCE OUTLET COMPRESSORS MODEL TONNAGE VOLTAGE RLA EACH LRA EACH OD FAN MOTOR FLA ID BLOWER MOTOR FLA CONV OUTLET FLA 208-1-60 25.0 150.0 2.3 7.6 0.0 230-1-60 25.0 150.0 2.3 7.6 0.0 208-3-60 17.3 123 2.3 5.2 0.0 230-3-60 17.3 123 2.3 5.2 0.0 460-3-60 8.4 70 1.3 2.6 0.0 575-3-60 7 53 1.3 2 0.0 208-3-60 18.6 156 2.3 5.2 0.0 230-3-60 18.6 156 2.3 5.2 0.0 460-3-60 9 75 1.3 2.6 0.0 575-3-60 7.4 54 1.3 2 0.0 DR060 DR072 ELECTRIC HEATER HEATER HEATER MODEL NO. KW AMPS None 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 2CE04513006 None 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 2CE04513006 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 2CE04513025 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 2CE04513025 None 2CE045107462 2CE045110462 2CE045115462 2CE045120462 2CE045130462 None 2CE04511058 2CE04511558 2CE04512058 2CE04513058 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 2CE04513025 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 2CE04513025 None 2CE045107462 2CE045110462 2CE045115462 2CE045120462 2CE045130462 None 2CE04511058 2CE04511558 2CE04512058 2CE04513058 -4.0 5.6 8.0 11.9 15.9 22.2 -5.3 7.5 10.6 15.9 21.2 29.6 -4.0 5.6 8.0 11.9 15.9 22.2 -5.3 7.5 10.6 15.9 21.2 29.6 -6.8 10.1 13.6 19.5 28.8 -10.6 15.9 21.2 30.4 -4.0 5.6 8.0 11.9 15.9 22.2 -5.3 7.5 10.6 15.9 21.2 29.6 -6.8 10.1 13.6 19.5 28.8 -10.6 15.9 21.2 30.4 -19.2 26.9 38.5 57.2 76.4 106.7 -22.1 31.3 44.2 66.3 88.3 123.3 -11.1 15.5 22.2 33.0 44.1 61.6 -12.7 18.0 25.5 38.2 51.0 71.2 -8.2 12.1 16.4 23.5 34.6 -10.2 15.3 20.4 29.3 -11.1 15.5 22.2 33.0 44.1 61.6 -12.7 18.0 25.5 38.2 51.0 71.2 -8.2 12.1 16.4 23.5 34.6 -10.2 15.3 20.4 29.3 MIN. MAX. FUSE/ CIRCUIT BRKR1 SIZE AMPACITY (AMPS) (AMPS) 41.2 45 41.2 45 43.2 60 57.6 60 81.0 90 105.1 110 142.9 150 41.2 45 41.2 45 48.6 60 64.7 70 92.3 100 119.9 125 163.7 175 29.1 35 29.1 35 29.1 35 34.3 45 47.8 50 61.7 70 83.5 90 29.1 35 29.1 35 29.1 35 38.4 45 54.3 60 70.2 80 95.5 100 14.4 20 14.4 20 18.4 20 23.7 25 32.6 35 46.6 50 11.8 15 15.2 20 21.6 25 28.0 30 39.1 40 30.8 40 30.8 40 30.8 40 34.3 45 47.8 50 61.7 70 83.5 90 30.8 40 30.8 40 30.8 40 38.4 45 54.3 60 70.2 80 95.5 100 15.1 20 15.1 20 18.4 20 23.7 25 32.6 35 46.6 50 12.3 15 15.2 20 21.6 25 28.0 30 39.1 40 1. HACR Typer Per NEC. 2. These electric heaters DO NOT include a fuse box. If a fuse box is required to meet a local code (e.e. Chicago), the fuse block accessories 2FB04700825 and 2FB04700846 are available for field installation. Unitary Products Group 41 036-21685-002-A-1105 TABLE 35: ELECTRICAL DATA - DR036 AND DR048 WITH POWERED CONVENIENCE OUTLET COMPRESSORS MODEL TONNAGE VOLTAGE RLA EACH LRA EACH OD FAN MOTOR FLA ID BLOWER MOTOR FLA CONV OUTLET FLA 208-1-60 11.8 68.0 2.3 7.6 10.0 230-1-60 11.8 68.0 2.3 7.6 10.0 208-3-60 8.3 68 2.3 5.2 10.0 230-3-60 8.3 68 2.3 5.2 10.0 460-3-60 5.1 34 1.3 2.6 5.0 575-3-60 3.2 26.0 1.3 2.0 4.0 208-1-60 15.4 86.0 2.3 7.6 10.0 230-1-60 15.4 86.0 2.3 7.6 10.0 208-3-60 11.5 84 2.3 5.2 10.0 230-3-60 11.5 84 2.3 5.2 10.0 460-3-60 5.8 42 1.3 2.6 5.0 575-3-60 5.1 34 1.3 2.0 4.0 DR036 DR048 ELECTRIC HEATER HEATER HEATER MODEL NO. KW AMPS None 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 None 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 None 2CE045107462 2CE045110462 2CE045115462 2CE045120462 None 2CE04511058 2CE04511558 2CE04512058 None 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 None 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 None 2CE045107462 2CE045110462 2CE045115462 2CE045120462 None 2CE04511058 2CE04511558 2CE04512058 -4.0 5.6 8.0 11.9 15.9 -5.3 7.5 10.6 15.9 21.2 -4.0 5.6 8.0 11.9 15.9 -5.3 7.5 10.6 15.9 21.2 -6.8 10.1 13.6 19.5 -10.6 15.9 21.2 -4.0 5.6 8.0 11.9 15.9 -5.3 7.5 10.6 15.9 21.2 -4.0 5.6 8.0 11.9 15.9 -5.3 7.5 10.6 15.9 21.2 -6.8 10.1 13.6 19.5 -10.6 15.9 21.2 -19.2 26.9 38.5 57.2 76.4 -22.1 31.3 44.2 66.3 88.3 -11.1 15.5 22.2 33.0 44.1 -12.7 18.0 25.5 38.2 51.0 -8.2 12.1 16.4 23.5 -10.2 15.3 20.4 -19.2 26.9 38.5 57.2 76.4 -22.1 31.3 44.2 66.3 88.3 -11.1 15.5 22.2 33.0 44.1 -12.7 18.0 25.5 38.2 51.0 -8.2 12.1 16.4 23.5 -10.2 15.3 20.4 MIN. MAX. FUSE/ CIRCUIT BRKR1 SIZE AMPACITY (AMPS) (AMPS) 34.7 45 46.0 50 55.7 60 70.1 80 93.5 100 117.6 125 34.7 45 49.6 50 61.1 70 77.2 80 104.8 110 132.4 150 28.3 35 32.9 35 38.4 40 46.8 50 60.3 70 74.2 80 32.3 40 34.9 40 41.6 45 50.9 60 66.8 70 82.7 90 15.3 20 19.7 20 24.7 25 29.9 30 38.8 40 12.2 15 20.2 25 26.6 30 33.0 35 39.1 50 46.0 50 55.7 60 70.1 80 93.5 100 117.6 125 39.1 50 49.6 50 61.1 70 77.2 80 104.8 110 132.4 150 31.9 40 32.9 40 38.4 40 46.8 50 60.3 70 74.2 80 31.9 40 34.9 40 41.6 45 50.9 60 66.8 70 82.7 90 16.1 20 19.7 20 24.7 25 29.9 30 38.8 40 13.4 15 20.2 25 26.6 30 33.0 35 1. HACR Typer Per NEC. 2. These electric heaters DO NOT include a fuse box. If a fuse box is required to meet a local code (e.e. Chicago), the fuse block accessories 2FB04700825 and 2FB04700846 are available for field installation. 42 Unitary Products Group 036-21685-002-A-1105 TABLE 36: ELECTRICAL DATA - DR060 AND DR072 WITH POWERED CONVENIENCE OUTLET COMPRESSORS MODEL TONNAGE VOLTAGE RLA EACH LRA EACH OD FAN MOTOR FLA ID BLOWER MOTOR FLA CONV OUTLET FLA 208-1-60 25.0 150.0 2.3 7.6 10.0 230-1-60 25.0 150.0 2.3 7.6 10.0 208-3-60 17.3 123 2.3 5.2 10.0 230-3-60 17.3 123 2.3 5.2 10.0 460-3-60 8.4 70 1.3 2.6 5.0 575-3-60 7.0 53 1.3 2.0 4.0 208-3-60 18.6 156 2.3 5.2 10.0 230-3-60 18.6 156 2.3 5.2 10.0 460-3-60 9.0 75 1.3 2.6 5.0 575-3-60 7.4 54 1.3 2.0 4.0 DR060 DR072 ELECTRIC HEATER HEATER HEATER MODEL NO. KW AMPS None 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 2CE04513006 None 2CE04510506 2CE04510706 2CE04511006 2CE04511506 2CE04512006 2CE04513006 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 2CE04513025 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 2CE04513025 None 2CE045107462 2CE045110462 2CE045115462 2CE045120462 2CE045130462 None 2CE04511058 2CE04511558 2CE04512058 2CE04513058 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 2CE04513025 None 2CE045105252 2CE045107252 2CE04511025 2CE04511525 2CE04512025 2CE04513025 None 2CE045107462 2CE045110462 2CE045115462 2CE045120462 2CE045130462 None 2CE04511058 2CE04511558 2CE04512058 2CE04513058 -4.0 5.6 8.0 11.9 15.9 22.2 -5.3 7.5 10.6 15.9 21.2 29.6 -4.0 5.6 8.0 11.9 15.9 22.2 -5.3 7.5 10.6 15.9 21.2 29.6 -6.8 10.1 13.6 19.5 28.8 -10.6 15.9 21.2 30.4 -4.0 5.6 8.0 11.9 15.9 22.2 -5.3 7.5 10.6 15.9 21.2 29.6 -6.8 10.1 13.6 19.5 28.8 -10.6 15.9 21.2 30.4 -19.2 26.9 38.5 57.2 76.4 106.7 -22.1 31.3 44.2 66.3 88.3 123.3 -11.1 15.5 22.2 33.0 44.1 61.6 -12.7 18.0 25.5 38.2 51.0 71.2 -8.2 12.1 16.4 23.5 34.6 -10.2 15.3 20.4 29.3 -11.1 15.5 22.2 33.0 44.1 61.6 -12.7 18.0 25.5 38.2 51.0 71.2 -8.2 12.1 16.4 23.5 34.6 -10.2 15.3 20.4 29.3 MIN. MAX. FUSE/ CIRCUIT BRKR1 SIZE AMPACITY (AMPS) (AMPS) 51.2 70 51.2 70 44.7 70 70.1 80 93.5 100 117.6 125 155.4 175 51.2 70 51.2 70 61.1 70 77.2 80 104.8 110 132.4 150 176.2 200 39.1 50 39.1 50 39.1 50 46.8 50 60.3 70 74.2 80 96.0 100 39.1 50 39.1 50 41.6 50 50.9 60 66.8 70 82.7 90 108.0 110 19.4 25 19.7 25 24.7 25 29.9 30 38.8 40 52.8 60 15.8 20 20.2 25 26.6 30 33.0 35 44.1 45 40.8 50 40.8 50 40.8 50 46.8 50 60.3 70 74.2 80 96.0 100 40.8 50 40.8 50 41.6 50 50.9 60 66.8 70 82.7 90 108.0 110 20.1 25 20.1 25 24.7 25 29.9 30 38.8 40 52.8 60 16.3 20 20.2 25 26.6 30 33.0 35 44.1 45 1. HACR Typer Per NEC. 2. These electric heaters DO NOT include a fuse box. If a fuse box is required to meet a local code (e.e. Chicago), the fuse block accessories 2FB04700825 and 2FB04700846 are available for field installation. Unitary Products Group 43 036-21685-002-A-1105 TABLE 37: PHYSICAL DATA DR MODELS EVAPORATOR BLOWER 036 048 060 072 Centrifugal Blower (Dia. x Wd. in.) 12 X 10 12 X 10 12 X 10 12 X 10 Fan Motor HP (Belt Drive) 1 1/2 1 1/2 1 1/2 1 1/2 Rows Deep 3 4 4 4 Fins Per Inch 13 13 13 13 Face Area (Sq. Ft.) 5.1 5.1 5.1 5.1 Propeller Dia. (in.) 24 24 24 24 Fan Motor Hp 1/2 1/2 1/2 1/2 4500 EVAPORATOR COIL CONDENSER FANS Nom. CFM 4500 4500 4500 Rows Deep 2 2 2 2 Fins Per Inch 18 18 18 18 Face Area (Sq. Ft.) 17.1 17.1 17.1 17.1 Qty / Type 1/Recip 1/Recip 1/Scroll 1/Scroll Quantity Per Unit (15” X 20” X 1” or 2“) 2 2 2 2 Quantity Per Unit (14” X 25” X 1” or 2“) 1 1 1 1 Total Face Area (sq. ft.) 6.6 6.6 6.6 6.6 Refrigerant 22 (lbs./oz.) 10/8 10/0 10/0 10/0 CONDENSER COILS COMPRESSOR (Qty. Per Unit) AIR FILTERS CHARGE TABLE 38: ELECTRIC HEAT CORRECTION FACTORS NOMINAL VOLTAGE VOLTAGE kW CAP. MULTIPLIER 208 208 1.00 TABLE 39: VOLTAGE LIMITATIONS1 VOLTAGE POWER SUPPLY MIN. MAX. 208/230-1-60 187 252 240 230 0.92 480 460 0.92 208/230-3-60 187 252 600 575 0.92 460-3-60 432 504 575-3-60 540 630 1. Utilization Range “A” in accordance with ARI Standard 110. 44 Unitary Products Group 036-21685-002-A-1105 TYPICAL POWER WIRING REFER TO THE ELECTRICAL DATA TABLES TO SIZE THE DISCONNECT SWITCH, OVERCURRENT PROTECTION AND WIRING. TYPICAL CONTROL WIRING &22/,1*+($7,1*92/7 7+(50267$7 &22/,1*21/<92/7 7+(50267$7 7+(50267$7 7(50,1$/6 7+(50267$7 81,7 7(50,1$/ 7(50,1$/6 675,3 7% 59 5 <& < $'' -803(5 92/7 75$16)250(5 5+ 81,77(50,1$/ 675,37% 5& 5 < < < < : : * *) 92/7 75$16)250(5 : & * * '(+80,',67$7 <(/ ` <(/ :,5(6/2&$7(',1 81,7&21752/%2; /2:92/7$*(6(&7,21 & 92/7 7+(50267$77+72&21752/ 7+((&2120,=(5 216(&21'67$*(&22/,1*86(7+( 7+(50267$77+ '(+80,',67$7 '(+80,',67$7&/26(6215,6(,1+80,',7< &22/,1*+($7,1*(/(&7521,&7+(50267$7 08/7,67$*( 7+(50267$7 7(50,1$/6 81,77(50,1$/ 675,37% 5& $'' -803(5 5+ 5 < < < * % & /(' /(' &20 $'' -803(5 ; 127 86(' 7+(50267$7 7(50,1$/6 5+ $'' -803(5 2&& 81,77(50,1$/ 675,37% 5& 5 < < : : * * & $ 92/7 75$16)250(5 $ 725(027(6(1625 7+,)86(' 7 7 '(+80,',67$7 <(/ <(/ :,5(6/2&$7(',1 '(+80,',67$7 ` 81,7&21752/%2; /2:92/7$*(6(&7,21 (/(&7521,&352*5$00$%/(7+(50267$7(7,1&/8'(668%%$6( <(/ <(/ :,5(6/2&$7(',1 ` 81,7&21752/%2; /2:92/7$*(6(&7,21 72&21752/7+((&2120,=(5216(&21'67$*(&22/,1*86(7+(50267$7 7+ 6(&21'67$*(&22/,1*,61275(48,5('2181,76/(66(&2120,=(5 6(&21'67$*(+($7,1*,621/<5(48,5('2181,76:,7+$7:267$*( (/(&75,&+($7(5257:267$*(*$6+($7 5(029(-803(5-)5207(50,1$/6$1'21-803(53/8*&211(&725 32181,76:,7+(&2120,=(57(50,1$/6 $ $1' $3529,'($5(/$< 287387 72&/26(7+(287'225(&2120,=(5'$03(56:+(17+( 7+(50267$76:,7&+(672 7+(6(7%$&.326,7,21 (/(&7521,&352*5$00$%/(7+(50267$7(7,1&/8'(668%%$6( :,5(6/2&$7(',1 ` 81,7&21752/%2; /2:92/7$*(6(&7,21 &22/,1*+($7,1*(/(&7521,&7+(50267$7 6,1*/(67$*( 92/7 75$16)250(5 : * <(/ '(+80,',67$7&/26(6215,6(,1+80,',7< : : <(/ 92/7 7+(50267$7(7 72&21752/ 7+((&2120,=(5217+(6(&21' 67$*(&22/,1*2572+$9($1(/(&75,&+($7$&&(6625< :,7+ 7:267$*(62) +($786(7+(50267$77+ < : '(+80,',67$7&/26(6215,6(,1+80,',7< '(+80,',67$7&/26(6215,6(,1+80,',7< FIGURE 6 - TYPICAL FIELD POWER & CONTROL WIRING Unitary Products Group 45 036-21685-002-A-1105 FIGURE 7 - UNIT DIMENSIONS (3 - 6 TON COOLING ONLY/ELECTRIC HEAT) FRONT VIEW FIGURE 8 - UNIT DIMENSIONS (3 - 6 TON COOLING/GAS HEAT) FRONT VIEW 46 Unitary Products Group 036-21685-002-A-1105 DETAIL “A” FIGURE 9 - UNIT WITH ECONOMIZER RAINHOOD DETAIL “B” FIGURE 10 - UNIT WITH FIXED OUTDOOR AIR/MOTORIZED DAMPER RAINHOOD Unitary Products Group 47 036-21685-002-A-1105 FIGURE 11 - UNIT DIMENSIONS (REAR VIEW) TABLE 41: MINIMUM CLEARANCES FILTER ACCESS LOCATION CLEARANCE Front 24” (Cooling/Electric Heat) 32” (Gas Heat) Rear 12” (Less Economizer) 36” (With Economizer or Fixed Air/ Motorized Damper) Left Side (Filter Access) 24” (Less Economizer) 36” (With Economizer) Right Side (Cond. Coil) 24” BLOWER MOTOR ACCESS DOT PLUGS FIELD-SUPPLIED DISCONNECT SWITCH LOCATION MOUNTING BRACKET FOR DICONNECT SWITCH (Shipped attached to the blower housing inside the blower compartment) A,B WIRING ENTRY (See Detail “B”) CONTROL BOX ACCESS DISCONNECT SWITCH LOCATION AND MOTOR ACCESS PANEL FOR UNIT WITH “BELT-DRIVE” OPTION FIGURE 12 - DISCONNECT/BLOWER ACCESS LOCATION Below Unit1 0” Above Unit2 72” (For Condenser Air Discharge) 1. Units may be installed on combustible floors made from wood or class A, B, or C roof covering material. 2. Units must be installed outdoors. Overhanging structures or shrubs should not obstruct condenser air discharge outlet. TABLE 40: UTILITIES ENTRY HOLE OPENING SIZE (DIA.) USED FOR A 7/8” KO1 Control Wiring2 B 2” KO1 Power Wiring C 1-5/8” KO Gas Piping (Front) D 1-1/2” KO Gas Piping (Bottom) Side Bottom Side Bottom 1. Opening in the bottom to the unit can be located by the side in the insulation. 2. Do not remove the 2” knockout ring. 48 Unitary Products Group 036-21685-002-A-1105 FIGURE 13 - TYPICAL APPLICATIONS Unitary Products Group 49 036-21685-002-A-1105 BACK OF UNIT A 447/8 BACK OF UNIT A 447/8 821/4 821/4 D B F X X B APPROXIMATE CENTER OF GRAVITY CONDENSER COIL END OF UNIT C Y FRONT OF UNIT C E APPROXIMATE CENTER OF GRAVITY CONDENSER COIL END OF UNIT D Y FRONT OF UNIT FIGURE 14 - FOUR AND SIX POINT LOADING TABLE 42: DR 4 AND 6 POINT LOADS WEIGHT DISTRIBUTION UNIT TOTAL 4-Point Loading (lb) 6-Point Loading (lb) A B C D A B C D E F DR036 Cooling/ Electric 569 133 120 150 166 90 84 79 98 105 113 DR036N04 609 143 129 160 178 97 90 84 105 112 120 DR036D06 619 145 131 163 180 98 92 86 107 114 122 DR036N08 629 147 133 165 183 100 93 87 108 116 124 DR036D10 639 150 135 168 186 102 95 89 110 118 126 DR048 Cooling/ Electric 566 133 120 149 165 90 84 78 97 104 112 DR048(D,N)06 616 144 130 162 180 98 91 85 106 114 122 DR048(D,N)10 636 149 134 167 185 101 94 88 110 117 126 DR060 Cooling/ Electric 580 136 123 152 169 92 86 80 100 107 115 DR060D06 630 148 133 166 184 100 93 87 109 116 125 DR060N08 640 150 135 168 187 102 95 89 110 118 127 DR060(D,N)10 650 152 137 171 189 103 96 90 112 120 129 DR072 Cooling/ Electric 582 136 123 153 170 93 86 81 100 107 115 DR072D06 632 148 134 166 184 100 94 88 109 116 125 DR072N08 642 150 136 169 187 102 95 89 111 118 127 DR072(D,N)10 652 153 138 171 190 104 97 90 112 120 129 TABLE 43: CENTER OF GRAVITY DIMENSION 3 - 6 TON X 44” Y 19-¾” 50 Unitary Products Group 036-21685-002-A-1105 TABLE 44: OPERATING WEIGHTS (LBS.) MODEL SIZE 3 TON 4 TON 5 TON 6 TON 569 566 580 582 N04 609 - - - N06 - 616 - - N08 629 - 640 642 N10 - 636 650 652 D06 619 616 630 632 D10 639 636 650 652 DR (Cooling Only) BASIC UNIT DR (Gas/Electric) Economizer 50 Motorized Damper OPTIONS Electric Heater ACCY. 26 5 - 7 kW 18 10 - 15 kW 23 20 - 30 kW 28 Roof Curb 92 Barometric Relief / Fixed Air Damper 10 FIGURE 15 - ROOF CURB DIMENSIONS Unitary Products Group 51 036-21685-002-A-1105 GUIDE SPECIFICATIONS GENERAL Units shall be manufactured by York International Unitary Products Group in an ISO 9001 certified facility. York's Sunline MagnaDRYTM units are convertible single packageunits. Although the units are primarily designed for curb mounting on a roof, they can also be slab-mounted at ground level or set on steel beams above a finished roof. Cooling only, cooling with gas heat and cooling with electric heat models are available with a wide variety of factory-mounted options and field-installed accessories to make them suitable for almost every application. All units are self-contained and assembled on full perimeter base rails with holes in the four corners for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to simplify the field installation and to provide years of dependable operation. All models (including those with an economizer) are suitable for either bottom or horizontal duct connections. Models with power exhaust are suitable for bottom duct connections only. For bottom duct, remove the sheet metal panels from the supply and return air openings through the base of the unit. For horizontal duct, remove the supply and return air panels on the rear of the unit. All compressors have internal pressure relief. Every refrigerant circuit includes a liquid line filter-drier, a discharge line high pressure switch and a suction line with a freezestat and low pressure/loss of charge switch.The unit control circuit includes a 75 VA transformer, a 24-volt circuit breaker and a relay board with a compressor lockout circuit, a terminal strip for thermostat wiring, plus an additional set of pin connectors to simplify the interface of additional field controls. All models are CSA listed. All models include a 1-year limited warranty on the complete unit. Compressors and electric heater elements carry a 5-year warranty. Aluminized steel and Stainless steel tubular heat exchangers carry a 10-year warranty. DESCRIPTION Units shall be factory-assembled, single packaged, Electric Cooling/Gas Heat, Electric Cooling/Optional Electric Heat and designed for outdoor mounted installation. The 3, 4 and 5 ton units have SEER ratings of 13.0 and the 6 ton unit is rated at 10.4 EER. They shall have built-in field convertible duct connections for down discharge supply/ return or horizontal discharge supply/return, and be available with factory installed options or field installed accessories. The units shall be factory wired, piped, charged with R-22 refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. All units the cooling performance shall be rated in accordance with ARI test procedures. Units shall be CSA listed, classified to ANSI Z21.47, UL 1995/CSA No. 236 standards. 52 UNIT CABINET Unit cabinet shall be constructed of G90 galvanized steel, with exterior surfaces coated with a non-chalking, powdered paint finish, certified at 1000 hours salt spray test per ASTMB117 standards. Indoor blower section shall be insulated with a minimum 1/2” thick insulation, coated on the airside. Aluminum foil faced insulation shall be used in the furnace compartment and be fastened with ridged fasteners to prevent insulation from entering the air stream. Cabinet panels shall be “large” size, easily removable for servicing and maintenance. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging and proper sealing on roof curb applications. Disposable 1" filters shall be furnished and be accessible through a removable access door, sealed airtight. Units filter track shall be designed to accommodate either 1” or 2” filters. Fan performance measuring ports shall be provided on the outside of the cabinet to allow accurate air measurements of evaporator fan performance without removing panels or creating air bypass of the coils. Condensate pan shall be internally sloped and conform to ASHRAE 62-89 self-draining standards. Condensate connection shall be a minimum of 3/4” I.D. female and be a ridged mount connection. INDOOR (EVAPORATOR) FAN ASSEMBLY The indoor fan shall be a factory installed belt drive assembly that includes an adjustable pitch motor pulley. Job site selected (B.H.P.) brake horsepower shall not exceed the motors nameplate horsepower rating, plus the service factor. Units shall be designed not to operate above service factor. Fan wheel shall be double-inlet type with forward-curved blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant air volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. OUTDOOR (CONDENSER) FAN ASSEMBLY The outdoor fan shall be of the direct-driven propeller type, discharge air vertically, have aluminum blades riveted to a corrosion resistant steel spider bracket and shall be dynamically balanced for smooth operation. The outdoor fan motor shall be totally enclosed with permanently lubricated bearings, internally protected against overload conditions and staged independently. REFRIGERANT COMPONENTS Compressor: a. Shall be internally protected with internal high-pressure relief and over temperature protection. b. Shall have internal spring isolation and sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, independent mounting. Unitary Products Group 036-21685-002-A-1105 Coils: GAS HEATING SECTION (SINGLE OR 2 STAGE) a. Evaporator and condenser coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed. Special Phenolic coating shall be available as a factory option. b. Evaporator and Condenser coils shall be of the direct expansion, draw-thru, design. Refrigerant Circuit and Refrigerant Safety Components shall include: Shall be designed with induced draft combustion with post purge logic, energy saving direct spark ignition, and redundant main gas valve. Venter wheel shall be constructed of stainless steel for corrosion resistance. The heat exchanger shall be of the tubular type, constructed of T1-40 aluminized steel for corrosion resistance and allowing minimum mixed air entering temperature of 25°F. Burners shall be of the inshot type, constructed of aluminum coated steel and contain air mixture adjustments. All gas piping shall enter the unit cabinet at a single location through either the side or curb, without any field modifications. Integrated control boards shall provide timed control of evaporator fan functioning and burner ignition. Heating section shall be provided with the following minimum protection: a. Thermal expansion devices (TXV’s). b. Filter drier/strainer to eliminate any moisture or foreign matter. c. Accessible service gage connections on both suction and liquid lines to charge, evacuate, and measure refrigerant pressure during any necessary servicing or troubleshooting without losing charge. a. Primary and auxiliary high-temperature limit switches. b. Induced draft motor speed sensor. c. Flame roll out switch. The refrigeration system shall provide at least 15°F of sub-cooling at design conditions. d. Flame proving controls. d. UNIT CONTROLS ELECTRIC HEATING SECTION a. Unit shall be complete with self-contained low-voltage control circuit protected by a resetable circuit breaker on the 24-volt transformer side. b. Unit shall incorporate a lockout circuit which provides reset capability at the space thermostat or base unit, should any of the following standard safety devices trip and shut off compressor. c. Loss-of-charge/Low-pressure switch. An electric heating section, with nickel chromium elements, shall be provided in a range of 5 thru 30 KW, offering two stages of capacity - 16 KW and above on 208/230 volt heaters and 20 KW and above on 460 and 575 volt heaters. The heating section shall have a primary limit control(s) and automatic reset to prevent the heating element system from operating at an excessive temperature. The heating section assembly shall slide out of the unit for easy maintenance and service. Units with Electric Heating shall be wired for a single point power supply with branch circuit fusing (where required). d. High-pressure switch. UNIT OPERATING CHARACTERISTICS e. Freeze-protection thermostat, evaporator coil. f. If any of the above safety devices trip, a LED (lightemitting diode) indicator shall flash a diagnostic code that indicates which safety switch has tripped. g. Unit shall incorporate “AUTO RESET” compressor over temperature, over current protection. h. Unit shall operate with conventional thermostat designs and have a low voltage terminal strip for easy hook-up. i. Unit control board shall have on-board diagnostics and fault code display. j. Standard controls shall include anti-short cycle and low voltage protection, and permit cooling operation down to 0°F. k. Control board shall monitor each refrigerant safety switch independently. l. Control board shall retain last 5 fault codes in non volatile memory, which will not be lost in the event of a power loss. OPTIONAL OUTDOOR AIR (Shall be made available by Unitary Products Group a. Unit shall be capable of starting and running at 125°F outdoor temperature, exceeding maximum load criteria of ARI Standard 210/240. The compressor, with standard controls, shall be capable of operation down to 0°F outdoor temperature. Unit shall be provided with fan time delay to prevent cold air delivery before heat exchanger warms up (Gas heat only). ELECTRICAL REQUIREMENTS All unit power wiring shall enter unit cabinet at a single factory provided location and be capable of side or bottom entry, to minimize roof penetrations and avoid unit field modifications. Separate side and bottom openings shall be provided for the control wiring. STANDARD LIMITED WARRANTIES • Compressor 5 Years • Heat Exchanger 10 Years • Electric Heat Element 5 Years • Other Parts 1 Year either/or): 53 036-21685-002-A-1105 • • ELECTRONIC ENTHALPY AUTOMATIC ECONOMIZER- Outdoor and return air dampers that are interlocked and positioned by a fully-modulating, spring return damper actuator. The maximum leakage rate for the outdoor air intake dampers shall not exceed 2% when dampers are fully closed and operating against a pressure differential of 0.5 IWG. A unit-mounted potentiometer shall be provided to adjust the outdoor and return air damper assembly to take in CFM of outdoor air to meet the minimum ventilation requirement of the conditioned space during normal operation. During economizer operation, a mixed-air temperature control shall modulate the outdoor and return air damper assembly to prevent the supply air temperature from dropping below 55°F. Changeover from compressor to economizer operation shall be provided by an integral electronic enthalpy control that feeds input into the basic module. The outdoor intake opening shall be covered with a rain hood that matches the exterior of the unit. Water eliminator/filters shall be provided. Simultaneous economizer/compressor operation is also possible. Dampers shall fully close on power loss. MOTORIZED OUTDOOR AIR DAMPERS - Outdoor air dampers are positioned by a 2-position, spring-return damper actuator. The maximum leakage rate for the outdoor air intake dampers shall not exceed 2% when dampers are fully closed and operating against a pressure differential of 0.5 IWG. A unit-mounted potentiometer shall be provided to adjust the outdoor damper assembly to take in the design CFM of outdoor air to meet the ventilation requirements of the conditioned space during normal operation. Whenever the indoor fan motor is energized, the dampers open up to one of two pre-selected positions - regardless of the outdoor air enthalpy. Dampers return to the fully closed position when the indoor fan motor is de-energized. Dampers shall fully close on power loss. • HIGH ALTITUDE - PROPANE GAS - Contains orifices required for applications between 2000 and 6000 feet altitude. Must be used with propane conversion kit. • LOW NOX - Required to reduce the emission of nitrogen oxides below 40 nanograms per joule. • GAS PIPING - Contains 1/2” pipe nipples, fittings and gas cock (including panel assess gaskets) required for bottom gas supply connection with external shut off. • POWER EXHAUST OPTION - To work in conjunction with economizers. • ELECTRIC HEATERS • ECONOMIZER/MOTORIZED DAMPER RAIN HOOD Contains all hood panels and the hardware for assembling. • MANUAL OUTDOOR AIR DAMPER • COIL GUARD KIT - Guard for cooling coil. • HAIL GUARD • FLUE EXHAUST EXTENSION OTHER FACTORY INSTALLED OPTIONS • POWER EXHAUST OPTION - To work in conjunction with economizers. • STAINLESS STEEL HEAT EXCHANGER • STAINLESS STEEL DRAIN PAN • BOTTOM DRAIN CONNECTION • TECHNICOAT PHENOLIC COATED CONDENSER AND EVAPORATOR COIL • ELECTRONIC SINGLE ENTHALPY ECONOMIZER • DIRTY FILTER SWITCH • PHASE MONITOR OTHER PRE-ENGINEERED ACCESSORIES AVAILABLE • COIL GUARD • ROOF CURB - 14"and 8” high, full perimeter curb with wood nailer (shipped knocked-down). • POWERED GFI CONVENIENCE OUTLET • NON-POWERED GFI CONVENIENCE OUTLET BAROMETRIC RELIEF DAMPER - Contains a rain hood, air inlet screen, exhaust damper and mounting hardware. Used to relieve internal air pressure through the unit. • BAS CONTROLS (Simplicity™ INTELLI- Comfort™, CPC, JOHNSON, HONEYWELL, NOVAR) • BAS READY ECONOMIZER (BELIMO ACTUATOR WITHOUT A CONTROLLER) • HINGED FILTER DOOR ACCESS AND TOOLESS ACCESS PANELS • 2" PLEATED FILTERS • DISCONNECT SWITCH • SUPPLY AIR SMOKE DETECTOR • RETURN AIR SMOKE DETECTOR • • PROPANE CONVERSION KIT - Contains new orifices and gas valve parts to convert from natural to L.P. gas. One per unit required. • HIGH ALTITUDE - NATURAL GAS - Contains orifices required for applications between 2000 and 6000 feet altitude. 54 Unitary Products Group 036-21685-002-A-1105 Unitary Products Group 55 Subject to change without notice. Printed in U.S.A. Copyright © 2005 by Unitary Products Group. All rights reserved. Unitary Products Group 5005 York Drive 036-21685-002-A-1105 Supersedes: 036-21685-001-B-0805 Norman OK 73069 ">
Advertisement
Key features
- Convertible air discharge
- Common cabinet & curb
- Powder paint finish
- Permanently lubricated motors
- Simplicity™ Control Board
- Copper tube/aluminum fin coils
- Easy access to components
- Rigging holes in base rails for lifting
- Fork lift slots on three sides
- Single point power connection
Frequently asked questions
The units have a SEER rating of 13.0.
There is a five-year parts warranty on the compressor and electric heat elements.
There is a ten-year parts warranty on the gas-fired heat exchangers.