Mitsubishi | Mr. Slim NH41NAD | Mitsubishi Residential Ductless Air Conditioners

Mitsubishi Residential Ductless Air Conditioners
Mr.Slim
®
Ductless Air Conditioning And
Heat Pump Product Guide
MITSUBISHI ELECTRONICS AMERICA, INC.
H VA C D I V I S I O N
3 1 0 0 AVA L O N R I D G E P L . S T E . 2 0 0 , N O R C R O S S , G A 3 0 0 7 1
C A L L : 7 7 0 - 6 1 3 - 5 8 4 0 O R 8 0 0 - 4 3 3 - 4 8 2 2 ( P R E S S 3 ) , FA X : 8 0 0 - 8 8 9 - 9 9 0 4
®
Mr.Slim
DUCTLESS AIR CONDITIONERS
AND HEAT PUMPS
Mr. Slim systems are unlike any other
products in the HVAC category. Actually they’re
a category in themselves because Mr. Slim is
probably the most unique innovation in air
comfort in two decades and one that has made
us the worldwide leader in ductless.
We designed Mr. Slim air conditioners and
heat pumps to solve cooling and heating
problems that other systems have never
addressed, specifically spot or zone cooling
and heating especially in retrofit situations.
These are voids in comfort that central air and
room air simply can’t fill economically and
attractively.
Where Mr. Slim Fits.
You’ll often encounter a hot or cold spot in
existing buildings that already have large
central systems. Is the answer to remodel and
make way for more ductwork? Obviously that’s
a small fortune. Should you opt for room air?
It’s unsightly at best, expensive to run, and a
real security hazard.
Now you’re beginning to see how Mr. Slim
fits in. It’s the ideal supplemental system for
cooling or heating those smaller zones with
absolutely no ductwork, no remodeling, and
few disruptions to business and traffic.
Our system is energy
efficient and whisper quiet.
Its remote control keeps all
operating functions and
data within a glance and
in easy reach. And it
neatly tucks away into
corners, blending in
with the room’s decor.
How Mr. Slim
Works.
Basically Mr. Slim is two units: an indoor air
handler and an outdoor compressor unit.
The two connect via refrigerant lines
through a three inch diameter opening in the
wall or ceiling. In fact that’s the toughest part of
installation: one hole.
You can locate the compact outdoor
compressor unit anywhere up to 164 feet away
from the air handler on select models: in many
cases. Many models have a front service panel
that clearly exposes all connections.
The indoor air handler is as easy to install
as a ceiling fan. And both the indoor and
outdoor units are microprocessor controlled.
Simple remotes let you control all functions.
COMFORT MADE SIMPLE.
1
MITSUBISHI ELECTRONICS
HVAC DIVISION
®
Mr.Slim WALL AND FLOOR MOUNTED UNITS
Light-to-medium capacity cooling and heating for
small area residential and commercial applications
MS/MSH/MF
2
SMALL AREA COOLING AND HEATING MADE SIMPLE.
The I Feel Remote Controller
At Mitsubishi we believe that
advancement in design is often a
matter of simplification. This wireless LCD remote controller is a
superb example. It lets the user
adjust the temperature instantly with
one tap of a button. And the
command language couldn’t be
easier. There’s a button for TOO
COOL and TOO WARM.
Swing
Remote
Auto
Air Flow
This series provides whisper-quiet operation
with airflow direction adjustments in both
vertical and horizontal directions.
Auto Cooling Mode
• Operation Mode Setting (I Feel, Cool, Dry, Heat)
• Computerized dehumidification in the dry mode
• Three Speed or Automatic Fan Control
• Twenty-Four Hour On/Off Timer
• Vane Control (automatically adjusts angle)
• Self-Diagnostic Display
Outdoor Compressor Unit
Mr. Slim outdoor compressor units are
extremely efficient and reliable and true spacesavers.
These models can be installed up to sixty
five feet away from the indoor unit. They
connect simply through a single three inch
opening in the wall or ceiling. No ductwork or
remodeling is necessary.
A continuous airflow from a horizontal vane
is the most efficient arrangement for air
conditioning to reach an ideal temperature in
the shortest time.
Remote Control
Using the remote controller you can select
from five different vertical airflow settings to
match the room layout and the location of
people.
Swing Mode
Swing mode ensures that a natural,
comfortable flow of air reaches every corner of
the room. Unnecessary cooling is avoided,
therefore contributing to economical operation.
The vent cover closes automatically when the
unit is turned off, leaving a sleek unit that is
pleasing to the eye.
Simplified Installation
Mr. Slim’s streamlined designs make indoor
units adaptable to an almost infinite variety of
room configurations. They’re simple to mount,
and they require a minimum of wiring. Naturally
they’re not only efficient but whisper-quiet, too.
You’ll hardly hear them running.
3
®
Mr.Slim
M SERIES AIR CONDITIONERS
AND HEAT PUMPS
Air Conditioners
MS17NN
Cooling capacity: 16,100 BTU/h
SEER: 10.2
Dimensions: W:39-15/16” D:7-1/2” H:12-5/8”
Floor Standing Air Conditioners
MS09NW
MS09NW
Cooling capacity: 8,500 BTU/h
SEER: 10.2
Dimensions: W:32-1/16” D:7-3/16” H:10-13/16”
MS12NN
Cooling capacity: 12,600 BTU/h
SEER: 11.3
Dimensions: W:39-15/16” D:7-1/2” H:12-5/8”
MS15NN
Cooling capacity: 14,600 BTU/h
SEER: 10.5
Dimensions: W:39-15/16” D:7-1/2” H:12-5/8”
Heat Pumps
MSH09NW
MSH09NW
Cooling capacity: 8,800 BTU/h
SEER: 10.0
Heating capacity: 10,500 BTU/h
HSPF: 6.8
Dimensions: W:32-1/16” D:7-3/16” H:10-13/16”
MF12EN
MF12EN
Cooling capacity: 12,000 BTU/h
SEER: 10.3
Dimensions: W:36-1/4” D:8-1/8” H:23-7/16”
MF15EN
Cooling capacity: 14,500 BTU/h
SEER: 10.0
Dimensions: W:36-1/4” D:8-1/8” H:23-7/16”
MSH12NN
Cooling capacity: 12,900 BTU/h
SEER: 10.2
Heating capacity: 13,500 BTU/h
HSPF: 6.8
Dimensions: W:39-15/16” D:7-1/2” H:12-5/8”
MSH15NN
Cooling capacity: 14,600 BTU/h
SEER 10.7
Heating capacity: 14,800 BTU/h
HSPF: 6.8
Dimensions: W:39-15/16” D:7-1/2” H:12-5/8”
MSH17NN
Cooling capacity: 16,200 BTU/h
SEER: 10.4
Heating capacity: 17,200 BTU/h
HSPF: 6.8
Dimensions: W:39-15/16 “ D:7-1/2” H:12-5/8”
Warranty
Mitsubishi is so confident of the reliability of Mr. Slim® Systems that we offer a six year
warranty on the compressor and a one year warranty on all other parts.
4
ITEM
Capacity
MS09NW
Cooling
*BTU/h
Heating 47° *BTU/h
Cooling
*1 W
Heating
*1 W
Cooling
MS12NN
8,500
12,600
—
—
Power
840
1,130
Consumption
—
—
EER
10.1
11.2
SEER
10.2
11.3
HSPF
—
—
COP
47° *1
—
—
INDOOR UNIT
MS09NW
MS12NN
External Finish
White
White
Power Supply
V, phase, Hz
115, 1, 60
115, 1, 60
Max. Fuze Size (time delay) A
15
15
Min. Ampacity
0.5
0.6
Fan Motor
F.L.A.
0.37
0.43
Airflow Lo-Hi
Dry
CFM
210-265-330 360-395-450
Wet
CFM
175-225-280 315-340-390
Moisture Removal
Pints/h
2.3
3.2
Sound Level
dB(A)
42
42
Cond. Drain Connection OD
in.
5/8
5/8
W
in.
32-1/16
39-15/16
Dimensions
D
in.
7-3/16
7-1/2
H
in.
10-13/16
12-5/8
Weight
18
31
OUTDOOR UNIT
MU09NW
MU12NN
External Finish
Sound Level
dB(A)
46
52
Power Supply
V, phase, Hz
115, 1, 60
208/230, 1, 60
Max. Fuse Size (time delay) A
15
15
Min. Ampacity
14
12
Fan Motor
F.L.A.
0.66
0.52
Model (type)
KH122WES RH167NHDT
Compressor
R.L.A.
10
9
L.R.A.
37
29
Refrigerant Control
Defrost method
—
—
W
in. 30-11/16
33-7/16
Dimensions
D
in.
10-1/16
11-7/16
H
in.
21-1/4
23-13/16
Weight
lbs.
64
92
REMOTE CONTROLLER
Control Voltage (by built- in transformer)
REFRIGERANT PIPING SIZE
1/4x3/8
MS15NN
MS17NN
MSH09NW MSH12NN MSH15NN MSH17NN
14,600
—
1,400
—
10.4
10.5
—
—
MS15NN
White
115, 1, 60
15
0.6
0.43
360-395-450
295-320-365
4.7
42
5/8
39-15/16
7-1/2
12-5/8
31
MU15NN
16,100
8,800
—
10,500
1,600
890
—
890
10.1
9.9
10.2
10
—
6.8
—
3.5
MS17NN MSH09NW
White
White
115, 1, 60 115, 1, 60
15
15
0.7
0.5
0.51
0.37
405-440-500 210-265-330
345-375-415 175-225-280
5.1
2.3
45
42
5/8
5/8
39-15/16
32-1/16
7-1/2
7-3/16
12-5/8
10-13/16
31
18
MU17NN MUH09NW
Munsell 5Y 6.5/1
52
52
49
208/230, 1, 60 208/230, 1, 60 115, 1, 60
20
20
20
14
15
16
0.52
0.52
0.7
RH207NHDT RH231NHDT RH140WGJT
10
11
12
35
38
42
12,900
14,600
16,200
13,500
14,800
17,200
1,310
1,380
1,580
1,250
1,300
1,570
9.8
10.6
10.3
10.2
10.7
10.4
6.8
6.8
6.8
3.2
3.3
3.2
MSH12NN MSH15NN MSH17NN
White
White
White
115, 1, 60 115, 1, 60
115, 1, 60
15
15
15
0.6
0.6
0.7
0.43
0.43
0.51
360-395-450 360-395-450 405-440-490
310-340-390 295-320-365 340-370-415
3.3
4.7
5.1
42
42
45
5/8
5/8
5/8
39-15/16
39-15/16
39-15/16
7-1/2
7-1/2
7-1/2
12-5/8
12-5/8
12-5/8
31
31
31
MUH12NN MUH15NN MUH17NN
Munsell 5Y 7/1
53
53
53
208/230, 1, 60 208/230, 1, 60 208/230, 1, 60
15
20
20
14
14
15
0.52
0.52
0.75
RH189NHDT RH207NHDT RH231NHDT
10
10
11
35
35
38
Capillary tube
—
33-7/16
11-7/16
23-13/16
92
1/4x5/8
—
Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle
33-7/16
30-11/16
33-7/16
33-7/16
34-1/4
11-7/16
10-1/16
11-7/16
11-7/16
11-5/8
23-13/16
21-1/4
23-13/16
23-13/16
33-1/2
97
80
99
99
97
Wireless type
DC12V
1/4x3/8
1/4x5/8
Note: For units using 208/230 volt the above ratings are at 230 volts.
5
MODEL
MF12EN
MF15EN
ITEM
Cooling Capacity
*1 BTU/h
12,000
14,500
Power Consumption
*1 W
1,180
1,470
EER
*1
10.2
9.9
SEER
10.3
10.0
INDOOR UNIT
MF12EN
MF15EN
External Finish
White
White
Power Supply
V, phase, Hz
115, 1, 60
Max. Fuse Size (time delay)
A
15
15
Min. Ampacity
0.5
0.5
Fan Motor
F.L.A.
0.4
0.4
Airflow Hi-Med-Lo
Dry
CFM 370-340-280
370-340-280
Wet
CFM 330-300-250
330-300-250
Moisture Removal
Pints/h
2.4
3.6
Sound Level
dB(A)
46
47
Cond. Drain Connection OD in.
5/8
W
in.
36-1/4
Dimensions
D
in.
8-1/8
H
in.
23-7/16
Weight
lbs.
59
OUTDOOR UNIT
ITEM
External Finish
Sound Pressure Level
dB(A)
Power Supply
V, phase, Hz
Max. Fuze Size (time delay) A
Min. Ampacity
Fan Motor
F.L.A.
Model (type)
R.L.A.
Compressor
L.R.A.
Refrigerant Control
W
in.
D
in.
Dimensions
H
in.
Weight
lbs.
REMOTE CONTROLLER
Control Voltage (by built- in transformer)
REFRIGERANT PIPING SIZE
MF12EN
MF15EN
Munsell 5Y 6.5/1
54
54
230, 1, 60
15
11
0.4
RH167NAB
8
29
20
13
0.4
RH207NAB
10
33
Capillary tube
33-1/2
11-7/16
23-7/8
99
Wireless type
DC12V
1/4, 1/2
* For 208 volt applications refer to Technical And
Service Manual for ratings.
®
Mr.Slim MULTI-SYSTEM
Light-to-medium capacity cooling for multi-area
residential and light commercial applications
MSM
6
®
Mr.Slim
MULTI-AREA COOLING
MADE SIMPLE.
Mr. Slim’s Multi-System allows two to three indoor units to operate from a single unit. It’s a lot
of cooling power in just a little space.
Two-To-One Cooling Multi-System
Two MS09NW indoor units operate from a single
outdoor unit.
MS09NW
Cooling capacity for single and double units: 8,500
BTU/h each
SEER: 10.2 each
Dimensions: W: 32-1/16”, D: 7-3/16”, H: 10-13/16”
MS09NW
MS09NW
MUM18NW
Dimensions: W: 33-1/2”, D: 11-7/16”, H: 23-7/8”
7
Features:
Warranty
• I Feel Remote Controller
• Simplified Installation
• Outdoor Compressor Unit
Mitsubishi is so confident of the reliability
of Mr. Slim® Systems that we offer a six year
warranty on the compressor and a one year
warranty on all other parts.
MODEL
MSM18NW
ITEM
Capacity
Cooling *1 BTU/h
Power
Cooling *1 W
Single
Double
OUTDOOR UNIT
MUM18NW
8,500
8,500x2
External Finish
Munsell 5Y 6.5/1
850
1,700
Sound Pressure Level
Consumption
Power Supply
dB(A)
EER
9.9
9.9
Max. Fuze Size (time delay)
SEER
10.2
10.2
Min. Ampacity
INDOOR UNIT
MS09NW (each)
External Finish
Power Supply
V, phase, Hz
Max. Fuze Size (time delay)
F.L.A.
Airflow Hi-Med-Lo
CFM
210-265-330
Wet
CFM
175-225-280
Pints/h
Sound Pressure Level
Cond. Drain Connection OD
Dimensions
in.
Capillary Tube
W
in.
33-1/2
D
in.
11-7/16
in.
23-7/8
H
lbs.
REMOTE CONTROLLER
Wireless type
12V DC
5/8
REFRIGERANT PIPING SIZE
1/4, 3/8
in.
D
in.
7-3/16
H
in.
10-13/16
32-1/16
lbs.
18
MSM30NN
ITEM
Triple-unit
A+B+C
Dbl.-unit
A+B A+C
or
B+C
Single-unit
A or B
C
Triple-unit
A+B+C
Cooling Capacity
*BTU/h
28,400
16,400 20,600 8,200 12,400 OUTDOOR UNIT
Power Consumption
*1W
2,870
1,830 2,060
980
Munsell 5Y 7/1
9.9
Sound Pressure Level
SEER (Triple unit operation)
10.2
Power Supply
A+B:MS09NWx2
C: MS15NN
C:MF15EN
Max. Fuze Size (time delay)
External Finish
White
White
White
Min. Ampacity
V, phase, Hz
A
Min. Ampacity
15
Compressor
F.L.A.
0.6
0.5
0.43
0.4
Dry
CFM
210-265-330
360-395-450
370-340-280
Wet
CFM
175-225-280
295-320-365
330-300-250
Pints/h
3.0
5.5
3.6
dB(A)
42X2
43
47
Weight
REMOTE CONTROLLER
Cond. Drain Connection OD
in.
Dimensions
W
in.
37-7/16
D
in.
15-3/8
in.
45-5/16
H
lbs.
5/8
5/8
5/8
39-15/16
36-1/4
Control Voltage (by built - in transformer)
7-1/2
8-1/8
REFRIGERANT PIPING SIZES
12-5/8
23-7/16
in.
D
in.
7-3/16
H
in.
10-13/16
18
31
59
lbs.
Capillary tube
Refrigerant Control
32-1/16
W
0.8+0.7
L.R.A
0.5
Sound Pressure Level
30
A
R.L.A.
0.37
Moisture Removal
Weight
Fan Motor
15
57
230, 1, 60 (3-wire)
25
F.L.A.
Fan Motor
Airflow Hi-Med-Lo
115,1,60
15
dB(A)
V, phase, Hz
INDOOR UNIT
Max. Fuze Size (time delay)
Dbl.-unit
Single-unit
A+B A+C A or B C
or
B+C
MUM30NN
1,220 External Finish
EER (Triple unit operation)
Dimensions
122
Control Voltage (by built- in transformer)
MODEL
Power Supply
10x2
42
W
Weight
1.0
R.L.A.
Weight
2.3 / Unit
dB(A)
14+13
37x2
Dimensions
0.37
Dry
Moisture Removal
F.L.A.
Refrigerant Control
0.5
Fan Motor
15x2
L.R.A.
15
Min. Ampacity
A
Compressor
115, 1, 60
A
230, 1, 60 (3-wire)
14
Fan Motor
White
56.5
V, phase, Hz
240
Wireless Type
DC 12V
MS09: 1/4, 3/8 MS15: 1/4, 5/8
* For 208 volt applications refer to Technical And Service Manual for ratings.
8
®
Mr.Slim
M SERIES HEAT PUMPS
WITH AUXILIARY HEAT
Heat Pumps
MSH09EW
MSH09EW
Cooling capacity: 8,800 BTU/h
SEER: 10.0
Heating capacity: 10,300 BTU/h
(13,700 w/ aux. booster heat)
HSPF: 6.8
Dimensions:
W:31-1/8” D:5-3/8” H:14-3/16”
MSH12EN
Cooling capacity: 12,500 BTU/h
SEER: 10.0
Heating capacity: 12,500 BTU/h
(17,600 w/ aux. booster heat)
HSPF: 6.8
Dimensions:
W:39-3/8 “ D:7” H:14-3/16”
The I Feel Remote Controller
At Mitsubishi we believe that
advancement in design is often a
matter of simplification. This wireless
LCD remote controller is a superb
example. It lets the user adjust the
temperature instantly with one tap of a
button. And the command language
couldn’t be easier. There’s a blue
button for TOO COOL, green for
OKAY and red for TOO WARM.
• Operation Mode Setting (Cool, Dry, Heat)
• Three Speed or Automatic Fan Control
• Twelve Hour On/Off Timer
• Vane Control (automatically adjusts angle)
9
MSH15EN
Cooling capacity: 14,200 BTU/h
SEER 10.0
Heating capacity: 14,500 BTU/h
(19,600 w/ aux. booster heat)
HSPF: 6.8
Dimensions:
W:39-3/8” D:7” H:14-3/16”
Hot Start System
Mr. Slim heat pumps provide warmth right
from the beginning. At the start of heating and
during defrosting, a very low fan speed
prevents the unit from blowing cold air into the
room. And a microprocessor controlled booster
heater speeds the warming process on some
models.
Warranty
Mitsubishi is so confident of the
reliability of Mr. Slim® Systems that we offer
a six year warranty on the compressor and
a one year warranty on all other parts.
ITEM
Capacity
Cooling
*BTU/h
Heating 47° *BTU/h
MSH09EW
MSH12EN
MSH15EN
8,800
12,500
14,200
10,300(13,700)
12,500(17,600)
14,500(19,600)
1,210/1,260
1,380/1,430
Power
Cooling
*1 W
890
Consumption
Heating
*1 W
920(1,920)
1,150(2,650)
1,340(2,840)
9.9
9.9
9.9
SEER
10.0
10.0
10.0
HSPF
6.8
6.8
6.8
EER
COP
*1
47° *1
INDOOR UNIT
3.3
3.2
3.2
MSH09EW
MSH12EN
MSH15EN
External Finish
White
White
White
Power Supply
115, 1, 60
115, 1, 60
115, 1, 60
15
20
20
12
17
17
V, phase, Hz
Max. Fuze Size (time delay)
A
Min. Ampacity
Fan Motor
F.L.A.
Auxiliary Heater
Airflow Lo-Hi
A (kW)
Dry
Wet
Moisture Removal
Sound Level
0.5
0.5
13.0(1.5)
13.0(1.5)
CFM
175-200-260
280-375-425
280-375-425
CFM
150-175-230
265-355-405
265-355-405
Pints/h
2.9
3.4
4.4
dB(A)
43
48
48
in.
5/8
5/8
5/8
W
in.
31-1/8
39-3/8
39-3/8
D
in.
5-3/8
7
7
in.
14-3/16
14-3/16
14-3/16
Cond. Drain Connection OD
Dimensions
0.3
8.7(1.0)
H
Weight
OUTDOOR UNIT
24
37.5
37.5
MUH09EW
MUH12EN
MUH15EN
Munsell 5Y 6.5/1
External Finish
Sound Level
dB(A)
Power Supply
V, phase, Hz
Max. Fuse Size (time delay)
A
49
54
55
115, 1, 60
230, 1, 60
230, 1, 60
20
15
20
Min. Ampacity
16
12
14
Fan Motor
0.7
0.5
0.5
RH140WJK
RH185NFL
RH207NFL
R.L.A.
12
8.8
10
L.R.A.
42
30
35
F.L.A.
Model (type)
Compressor
Capillary tube
Refrigerant Control
Defrost method
Dimensions
Reverse Cycle
Reverse Cycle
Reverse Cycle
33-1/2
33-1/2
W
in.
30-11/16
D
in.
10-1/16
11-7/16(12-5/8)
11-7/16(12-5/8)
in.
21-1/4
23-7/8
23-7/8
104
104
H
Weight
lbs.
79
Wireless type
REMOTE CONTROLLER
Control Voltage (by built- in transformer)
1/4, 3/8
1/4, 5/8
REFRIGERANT PIPING SIZE
* For 208 volt applications refer to Technical And Service Manual for ratings.
10
Mr.Slim WALL MOUNTED UNITS
®
11
Medium-to-large capacity cooling and heating for
large area residential commercial applications
PK/PKH
LARGE AREA COOLING AND HEATING MADE SIMPLE.
Intelligent Remote Controller
Highly advanced microprocessor technology is
one reason why Mitsubishi leads the air comfort
category. This ultrathin microprocessor remote
controller with LCD display gives you a variety of
functions and options to keep room comfort
perfectly balanced. It lets
you check Mr. Slim’s
operating conditions with
just a glance. In the rare
case of a malfunction the
self-diagnostic system even
indicates specific problems
for easy repair.
• Computerized Dehumidification
• Operation Mode Setting (Heat, Auto, Cool/Dry)
• Temperature Setting (in units of two
degrees fahrenheit.)
• Self-Diagnostic Display
• Room Temperature Display
• Twenty-Four Hour On/Off Timer
• Fan Speed Indicator
• Auto/Swing Vane Operation
• Memory (for storing operation functions)
• Low Ambient Operation
• Whisper-Quiet Operation
• EMS Gateway Available To Management System
Via RS-232 Cable
Outdoor Compressor Unit
Mr. Slim outdoor compressor units are
extremely efficient and reliable, and true spacesavers.
These models can be installed up to 164
feet away from the indoor unit. They connect
simply with a single three to four inch conduit
through the wall or ceiling. No ductwork or
remodeling is necessary. As many as ten units
can be installed in a row for major space
savings.
Outdoor units are designed with
a front-access service panel that
provides easy access to all
maintenance points.
These
units
operate
in
temperatures as low as zero
fahrenheit when the optional wind
installed. So you can cool spaces
computer rooms year round.
outdoor
degrees
baffle is
such as
Mr. Slim heat pumps also feature automatic
cooling/heating changeover for simple control
and lower maintenance. You never have to
readjust the unit.
Swing
Auto Control Or Swing
Heating Mode
Redi-Charged System
Mr. Slim “P” Series features the industry’s
first redi-charged refrigerant system. There is
no need to adjust the amount of refrigerant to
match the piping length on-site unless lines
exceed 100 feet. You’ll see a major reduction in
installation time and labor costs. Plus you can
always count on Mr. Slim’s reliability from day
one because they’re thoroughly charged and
tested at the factory. You know it’s going to
work.
Hot Start System
Mr. Slim heat pumps provide warmth right
from the beginning. At the start of heating and
after defrosting, a very low fan speed prevents
the unit from blowing cold air into the room. And
a microprocessor controlled booster heater
speeds the warming process.
12
Air Conditioners
Heat Pumps
PK12FK
PKH 18FK
PK12FK
Cooling capacity: 12,500 BTU/h
SEER: 11.5
Dimensions:
W:49-7/32” D:7-7/8” H:11-13/16”
PKH18FK
Cooling capacity: 18,000 BTU/h
SEER: 11.1
Heating capacity:
18,600 BTU/h (25,100 w/ aux. booster heat)
HSPF: 7.2
Dimensions:
W:55-1/8” D:9-1/4” H:13-3/8”
PK18FK
Cooling capacity: 18,500 BTU/h
SEER: 11.3
Dimensions:
W:55-1/8” D:9-1/4” H:13-3/8”
PK24FK
Cooling capacity: 24,000 BTU/h
SEER: 10.6
Dimensions:
W:55-1/8” D:9-1/4” H:13-3/8”
PK30FK
Cooing capacity: 30,000 BTU/h
SEER: 10.7
Dimensions:
W:66-5/32” D:9-1/4” H:13-3/8”
PK36FK
Cooing capacity: 34,200 BTU/h
SEER: 10.2
Dimensions:
W:66-5/32” D:9-1/4” H:13-3/8”
Simplified Installation
Mr. Slim’s streamlined design makes indoor
units adaptable to an almost infinite variety of
room configurations. They’re simple to mount,
and they require a minimum of wiring. Naturally
they’re not only efficient but also whisper-quiet.
You’ll hardly hear them running.
Refrigerant lines may be connected to the
outdoor unit from the front, rear, or side, or
13
PKH24FK
Cooling capacity: 24,000 BTU/h
SEER: 10.2
Heating capacity:
25,000 BTU/h (31,500 w/ aux. booster heat)
HSPF: 6.8
Dimensions:
W:55-1/8” D:9-1/4” H:13-3/8”
PKH30FK
Cooling capacity: 30,000 BTU/h
SEER: 10.6
Heating capacity:
33,000 BTU/h (40,500 w/ aux. booster heat)
HSPF: 7.1
Dimensions:
W:66-5/32” D:9-1/4” H:13-3/8”
PKH36FK
Cooling capacity: 34,200 BTU/h
SEER: 10.5
Heating capacity:
38,000 BTU/h (45,500 w/ aux. booster heat)
HSPF: 6.9
Dimensions:
W:66-5/32” D:9-1/4” H:13-3/8”
beneath the base. This easy-access design lets
you arrange and install a number of units in a
small area.
Warranty
Mitsubishi is so confident of the
reliability of Mr. Slim® Systems that we offer
a six year warranty on the compressor and a
one year warranty on all other parts.
ITEM
MODEL
PK12FK PK18FK PK24FK PK30FK PK36FK PKH18FK PKH24FK PKH30FK PKH36FK
18,500
24,000
30,000
34,200
18,000
Cooling *1 BTU/h 12,500
—
—
—
—
—
18,600(24,100/25,100)
Heating *1 BTU/h
—
—
—
—
—
10,700(16,200/17,200)
Heating *2 BTU/h
1.2
1.75
2.34
3.06
3.47
1.79
Power
Cooling
*1 W
—
—
—
—
—
1.56(3.16/3.46)
Consumption Heating
*1 W
—
—
—
—
—
1.34(2.94/3.24)
Heating
*2 W
10.3
10.6
10.3
9.8
9.9
10.1
EER
Cooling
11.5
11.3
10.6
10.7
10.2
11.1
SEER
—
—
—
—
—
7.2
HSPF
—
—
—
—
—
3.5
COP
Heating
*1 W
—
—
—
—
—
2.3
Heating
*2 W
INDOOR UNIT
PK12FK PK18EK
PK24FK
PK30FK
PK36FK
PKH18FK
External Finish
Munsell 3.4Y7.7/0.8
Power Supply
V, phase, Hz
115, 1, 60
Max. Fuse Size (time delay) A
15
15
15
15
15
15
Min. Ampacity
1
1
1
2
2
12
Fan Motor
F.L.A.
0.7
0.7
0.7
1.0
1.0
0.5
Auxiliary Heater
A (kW)
—
—
—
—
—
7.6/8.4(1.6/1.9)
Airflow Hi-Lo
Dry
CFM
490-350
710-530
710-530
990-780
990-780
710-530
Wet
CFM
440-320
640-480
640-480
890-700
890-700
640-480
Moisture Removal
Pints/h
3.8
5.3
7.2
9.6
10.5
5.3
Sound Pressure Level Hi-Lo dB(A)
45-38
43-35
43-35
46-41
46-41
43-35
Cond. Drain Connection OD in.
1
1
1
1
1
1
W
in.
49-7/32
55-1/8
55-1/8
66-5/32
66-5/32
55-1/8
Dimensions
D
in.
7-7/8
9-1/4
9-1/4
9-1/4
9-1/4
9-1/4
H
in.
11-13/16
13-3/8
13-3/8
13-3/8
13-3/8
13-3/8
Weight
37
53
53
62
62
57
OUTDOOR UNIT
PU12EK PU18EK PU24EK PU30EK PU36EK
PUH18EK
External Finish
Munsell 5Y 7/1
Sound Pressure Level
dB(A)
50
53
55
55
55
53
Power Supply
V, phase, Hz
208/230, 1, 60
Max. Fuse Size (time delay) A
15
20
20
30
30
20
Min. Ampacity
11
16
16
20
22
16
Fan Motor
F.L.A.
0.65
0.75
0.65+0.65 0.65+0.65 0.75+0.75
0.75
Model (Type)
RH167NAB RH247NAB NH33NBD
NH41NAD
NH47NAD
RH247NAB
Compressor
R.L.A.
8.9
12
11.5
14
17.5
12
L.R.A.
29
37
54
73
87
37
Crankcase Heater
A(W) 0.11/0.12(23/28) 0.11/0.12(23/28) 0.16/0.17(33/39) 0.16/0.17(33/39) 0.16/0.17(33/39) 0.11/0.12(23/28)
Refrigerant Control
—
Capillary Tube
Defrost method
—
W
in.
34-1/4
34-1/4
34-1/4
34-1/4
38-3/16
34-1/4
Dimensions
D
in.
11-5/8
11-5/8
11-5/8
11-5/8
13-9/16
11-5/8
H
in.
25-9/16
33-1 /2
49-9/16
49-9/16
49-9/16
33-1/2
Weight
lbs.
105
154
207
208
220
131
REMOTE CONTROLLER
With indoor unit
Control Voltage (by built-in transformer)
Indoor unit-outdoor unit: DC 12V
REFRIGERANT PIPING SIZE
3/8x5/8
1/2x3/4
3/8x5/8
Capacity
24,000
30,000
34,200
25,000(30,500/31,500) 33,000(39,100/40,500) 38,000(44,100/45,500)
14,700(20,200/21,200) 19,000(25,100/26,500) 19,600(25,700/27,100)
2.36
3.12
3.44
2.37(3.97/4.27) 3.02(4.82/5.22) 3.54(5.34/5.74)
1.92(3.52/3.82) 2.48(4.28/4.68) 2.65(4.45/4.85)
10.2
9.6
9.9
10.2
10.6
10.5
6.8
7.1
6.9
3.1
3.2
3.1
2.2
2.2
2.2
PKH24FK
PKH30FK PKH36FK
208/230, 1, 60
15
15
15
12
13
13
0.5
0.6
0.6
7.6/8.4(1.6/1.9) 8.7/9.6(1.8/2.2) 8.7/9.6(1.8/2.2)
710-530
990-780
990-780
640-480
890-700
890-700
7.0
9.1
10.5
43-35
46-41
46-41
1
1
1
55-1/8
66-5/32
66-5/32
9-1/4
9-1/4
9-1/4
13-3/8
13-3/8
13-3/8
57
66
66
PUH24EK PUH30EK PUH36EK
55
55
55
20
16
0.65+0.65
NH33NBD
11.5
54
30
20
0.75+0.75
NH41NAD
14
73
30
22
0.75+0.75
NH47NAD
17.5
87
0.16/0.17(33/39)
0.16/0.17(33/39)
0.16/0.17(33/39)
Reverse Cycle
34-1/4
38-3/16
11-5/8
13-9/16
49-9/16
49-9/16
202
245
38-3/16
13-9/16
49-9/16
246
1/2x3/4
*1 Rating conditions (cooling): Indoor: 80°F DB, 67°F WB,Outdoor: 95°F DB, 75°F WB, (heating) - indoor: 70°
DB, 60°F WB Outdoor: 47°F DB, 43°F WB
*2 Rating conditions (heating): Indoor: 70°F DB, 60°F WB,Outdoor: 47°F DB, 43°F WB
*3 Heating capacity and power consumption in () include auxiliary electric heater operation at 208/230v.
Figures in parentheses include auxiliary heat. * For 208 volt applications refer to Technical And Service Manual
for ratings. Specifications are subject to change without notice.
14
General Specifications
Notes: For MS/MSH, MF, MSM
*1. Rating conditions (cooling)_____ Indoor: 80˚F DB, 67˚F WB Outdoor: 95˚F DB, 75˚F WB
(heating)_____ Indoor: 70˚F DB, 60˚F WB Outdoor: 47˚F DB, 43˚F WB
*2. Include auxiliary electric heater operations at 115V. (MSH09EW, MSH12EN, MSH15EN)
*3. Rated voltage of compressor and fan motor is 115V. (MUM18EW)
*4. Values are for each indoor unit.
*5. Depth of outdoor unit ( ) includes thickness of fan grille.
Operating Range
Indoor air intake temperature
MODEL
Maximum
Minimum
Maximum
Minimum
Cooling
Heating
95˚F
67˚F
80˚F
70˚F
DB,
DB,
DB,
DB,
71˚F
57˚F
67˚F
60˚F
Outdoor air intake temperature
WB
WB
WB
WB
115˚F DB
67˚F DB
75˚F DB, 65˚F WB
17˚F DB, 15˚F WB
Notes: For PK/PKH, PC/PCH, PL/PLH
* 1. Rating conditions (cooling)_____ Indoor: 80˚F DB, 67˚F WB Outdoor: 95˚F DB, 75˚F WB
(heating)_____ Indoor: 70˚F DB, 60˚F WB Outdoor: 47˚F DB, 43˚F WB
* 2. Rating conditions (heating)_____ Indoor: 70˚F DB, 60˚F WB Outdoor: 17˚F DB, 15˚F WB
* 3. Heating capacity and power consumption in [ ] include auxiliary electric heater operation at 208/230V.
Operating Range
Indoor air intake temperature
MODEL
Cooling
Heating
Maximum
Minimum
Maximum
Minimum
95˚F
67˚F
80˚F
70˚F
DB,
DB,
DB,
DB,
71˚F
57˚F
67˚F
60˚F
Outdoor air intake temperature
WB
WB
WB
WB
115˚F DB
*5
0˚F DB
75˚F DB, 65˚F WB
17˚F DB, 15˚F WB
*5 With Wind Baffle installed.
REFRIGERANT TUBING SIZE
Refrigerant Tubing
MODEL
Max. Height
Difference (ft)
Max. Tubing
Length (ft)
25
49
MS09EW
(MS09EWX2•MS15ENX1) MS15EN
25
65
MS12EN, MS15EN, MSH12EN, MSH15EN
25
49
PK18EK, PKH18EK, PL18FK, PLH18FK,
PK12EK, PL12FK
130
130
Tubing (OD)/N
Liquid
3/8
MS09EW, MSH09EW, MSM18EW
MF12EN, MF15EN
MSM30EN
1/2
1/4
3/8
5/8
Flared
3/8
5/8
1/2
3/4
PK24EK, PKH24EK, PC24EK, PCH24FK,
PL24FK, PK24EK
PK30EK, PKH30EK, PL30FK, PLH30FK,
PC30EK, PCH30EK, PL36FK, PLH36FK,
PC36EK, PCH36EK, PL42FK2, PC42EK
PLH42FK, PCH42EK
Gas
Connection
Method
164
164
7/8
*For more details refer to Technical And Service Manual. All specifications are subject to change without notice.
MITSUBISHI ELECTRONICS AMERICA, INC.
HVAC DIVISION
3100 AVALON RIDGE PL. STE. 200, NORCROSS, GA 30071
CALL: 770-613-5840 OR 800-433-4822 (PRESS 3) FAX: 800-889-9904
Form No. MIT-MRS-24-97
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising