Kärcher Dominator NMWU2250H, NMWC1350N Extractor Operators Manual
Below you will find brief information for Extractor Dominator NMWU2250H, Extractor Dominator NMWC1350N. The Dominator is an electric powered carpet extractor intended for commercial use. This appliance applies a cleaning solution to the carpet and then vacuums the soiled water back into the recovery tank.
Advertisement
Advertisement
Dominator 500 PSI 17 Gallon
Extractor
Operating instructions (ENG)
MODELS:
NMWU2250H
10066670
NMWC1350N
10066680
From Serial Number (Ref No. 1*)
* See Serial number page or call Manufacturer.
86399150-A 01/02/15
Machine Data Label
Overview
The Dominator is an electric powered carpet extractor intended for commercial use. This appliance applies a cleaning solution to the carpet and then vacuums the soiled water back into the recovery tank.
2
Warranty Registration
Thank you for purchasing a Kärcher North America product. Warranty registration is quick and easy. Your registration will allow us to serve you better over the lifetime of the product.
To register your product go to : http://warranty.karcherna.com/
For customer assistance:
1-800-444-7654
86399150 Operators Manual - Dominator 500 PSI 17 Gallon
Machine Data Label . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
How To Use This Manual . . . . . . . . . . . . . . . . . . . . . 4
Safety
IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . 5
HAZARD INTENSITY LEVEL . . . . . . . . . . . . . . . . . . 6
Safety Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Grounding Instructions . . . . . . . . . . . . . . . . . . . . . . . 8
Operations
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . 9
Controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Machine Operation . . . . . . . . . . . . . . . . . . . . . . . . . 11
Chemicals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Pre-Run Inspection . . . . . . . . . . . . . . . . . . . . . . . . . 12
Equipment Set-up . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Heater Operation . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Maintenance
Periodic Maintenance . . . . . . . . . . . . . . . . . . . . . . . 14
Daily/Regular Maintenance. . . . . . . . . . . . . . . . . . . 14
Vacuum Motor Replacement . . . . . . . . . . . . . . . . . 15
Solution Pump Replacement . . . . . . . . . . . . . . . . . 16
Pressure Regulator . . . . . . . . . . . . . . . . . . . . . . . . . 17
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Suggested Spare Parts. . . . . . . . . . . . . . . . . . . . . . 20
Table of Contents
86399150 Operators Manual - Dominator 500 PSI 17 Gallon 3
How To Use This Manual
This manual contains the following sections:
• How to Use This Manual
• Safety
• Operations
• Maintenance
• Suggested Spare Parts
The HOW TO USE THIS MANUAL section will tell you how to find important information for ordering correct repair parts.
Parts may be ordered from authorized dealers. When placing an order for parts, the machine model and machine serial number are important. Refer to the
MACHINE DATA box which is filled out during the installation of your machine. The MACHINE DATA box is located on the inside of the front cover of this manual.
The SAFETY section contains important information regarding hazardous or unsafe practices of the machine. Levels of hazards are identified that could result in product damage, personal injury, or severe injury resulting in death.
The OPERATIONS section is to familiarize the operator with the operation and function of the machine.
The MAINTENANCE section contains preventive maintenance to keep the machine and its components in good working condition. They are listed in this general order:
• Maintenance
• Lubrication
• Vacuum Motor Replacement
• Solution Pump Replacement
• Troubleshooting
Model:
Date of Purchase:
Serial Number:
Dealer:
Address:
Phone Number:
Sales Representative:
NOTE: If a service or option kit is installed on your machine, be sure to keep the KIT INSTRUCTIONS which came with the kit. It contains replacement parts numbers needed for ordering future parts.
NOTE: The manual part number is located on the lower right corner of the front cover.
The model and serial number of your machine is located on the back of the machine.
4 86399150 Operators Manual - Dominator 500 PSI 17 Gallon
Safety
IMPORTANT SAFETY INSTRUCTIONS
When using this machine, basic precaution must always be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE.
To reduce the risk of fire, electric shock, or injury:
Connect to a properly grounded outlet. See Grounding Instructions.
Do not leave the machine unattended. Unplug machine from outlet when not in use and before maintenance or service.
Use only indoors. Do not use outdoors or expose to rain.
Do not allow machine to be used as a toy. Close attention is necessary when used by or near children.
Use only as described in this manual. Use only manufacturer's recommended components and attachments.
Do not use damaged electrical cord or plug. Follow all instructions in this manual concerning grounding the machine. If the machine is not working properly, has been dropped, damaged, left outdoors, or dropped into water, return it to an authorized service center.
Do not pull or carry machine by electrical cord, use as a handle, close a door on cord, or pull cord around sharp edges or corners.
Do not run machine over cord. Keep cord away from heated surfaces.
Do not unplug machine by pulling on cord. To unplug, grasp the electrical plug, not the electrical cord.
Do not handle the electrical plug or machine with wet hands.
Do not operate the machine with any openings blocked. Keep openings free of debris that may reduce airflow.
This machine is intended for cleaning carpet only.
Do not vacuum anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
This machine is not suitable for picking up health endangering dust.
Turn off all controls before unplugging.
Machine can cause a fire when operating near flammable vapors or materials. Do not operate this machine near flammable fluids, dust or vapors.
This machine is suitable for commercial use, for example in hotels, schools, hospitals, factories, shops and offices for more than normal housekeeping purposes.
Maintenance and repairs must be done by qualified personnel.
If foam or liquid comes out of machine, switch off immediately.
READ AND SAVE THESE INSTRUCTIONS
86399150 Operators Manual - Dominator 500 PSI 17 Gallon 5
Safety
The following symbols are used throughout this guide as indicated in their descriptions:
HAZARD INTENSITY LEVEL
There are three levels of hazard intensity identified by signal words -WARNING and CAUTION and FOR SAFETY.
The level of hazard intensity is determined by the following definitions:
WARNING - Hazards or unsafe practices which COULD result in severe personal injury or death.
CAUTION - Hazards or unsafe practices which could result in minor personal injury or product or property damage.
FOR SAFETY: To Identify actions which must be followed for safe operation of equipment.
Report machine damage or faulty operation immediately. Do not use the machine if it is not in proper operating condition. Following is information that signals some potentially dangerous conditions to the operator or the equipment. Read this information carefully. Know when these conditions can exist. Locate all safety devices on the machine. Please take the necessary steps to train the machine operating personnel.
FOR SAFETY:
DO NOT OPERATE MACHINE:
Unless Trained and Authorized.
Unless Operation Guide is Read and understood.
In Flammable or Explosive areas.
In areas with possible falling objects
WHEN SERVICING MACHINE:
Avoid moving parts. Do not wear loose clothing; jackets, shirts, or sleeves when working on the machine. Use manufacturer approved replacement parts.
6 86399150 Operators Manual - Dominator 500 PSI 17 Gallon
Safety
Safety Labels
NOTE: These drawings indicate the location of safety labels on the machine. If at any time the labels become illegible, promptly replace them.
86399150 Operators Manual - Dominator 500 PSI 17 Gallon 7
Safety
Grounding Instructions
THIS PRODUCT IS FOR COMMERCIAL
USE ONLY.
ELECTRICAL:
In the USA this machine operates on a standard 15 amp 115V, 60 hz, A.C. power circuit. The amp, hertz, and voltage are listed on the data label found on each machine. Using voltages above or below those indicated on the data label will cause serious damage to the motors.
EXTENSION CORDS:
If an extension cord is used, the wire size must be at least one size larger than the power cord on the machine, and must be limited to 50 feet (15.5m) in length.
GROUNDING INSTRUCTIONS:
This appliance must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and grounding plug. The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
This appliance is for use on a nominal 120-volt circuit, and has a grounded plug that looks like the plug in "Fig.
A". A temporary adapter that looks like the adaptor in
"Fig. C" may be used to connect this plug to a 2-pole receptacle as shown in "Fig. B", if a properly grounded outlet is not available. The temporary adapter should be used only until a properly grounded outlet (Fig. A) can be installed by a qualified electrician. The green colored rigid ear, lug, or wire extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box cover.
Whenever the adapter is used, it must be held in place by a metal screw.
Grounding Pin
Grounded
Outlet
FIGURE A
GROUNDING CONNECTION
USING AN ADAPTOR
Grounded
Outlet Box
Adaptor
Adaptor
Metal Screw
FIGURE B
Tab for Grounding
Screw
FIGURE C
Note: Adaptors are not allowed in Canada.
Improper connection of the equipment-grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
8 86399150 Operators Manual - Dominator 500 PSI 17 Gallon
Technical Specifications
MODEL
ALL
10066670
10066680
Electrical
Solution Pump
Solution Capacity
Recovery Capacity
Height
Length
Width
Vacuum Motor
Weight- Empty
Weight-Full Solution
Power cord
Heater
Vacuum Motor
Weight- Empty
Weight-Full Solution
Power cord
ITEM
Width
MEASURE
115 Volt, 60 hz, 15A
500 psi
17 Gal
14 Gal
43 inches
32.5 inches
22.5 inches
Dual 2 Stage
139 lbs
282 lbs
2 X 25 feet
1850 watts
Single 3 Stage
122 lbs
265 lbs
1 X 40 feet inline GFCI
Length
Operations
Height
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
86399150 Operators Manual - Dominator 500 PSI 17 Gallon 9
Operations
1
2
3
4
5
6
11
10
Controls
1.
Vacuum Accessory Tool Hook-up
2.
Solution Pump Switch
3.
Vacuum 1 Switch
4.
Vacuum 2 Switch (Dual Vacuum Units Only)
5.
Heater Switch with On Light (Units w/Heat Only)
6.
Pressure Gauge
9
8
7
7.
Adjustable Pressure Relief Valve
8.
Heater Temperature Light (Units w/Heat Only)
9.
Breaker for Vacuum 2 (Dual Vacuum Units Only)
10. Breaker for Vacuum 1
11. Solution Accessory Tool Hook-up
10 86399150 Operators Manual - Dominator 500 PSI 17 Gallon
Machine Operation
Care must be exercised in the use of all chemicals.
Chemicals are poisonous and can pose a health risk.
Read and follow manufacturers instructions regarding dangers and correct usages.
Operations
Only use chemicals approved for use with this machine. Use of non-compatible chemicals may cause machine damage and will not be covered under the warranty. Carefully read ingredients on manufacturer’s label before using any product in this machine.
Do not let pump run dry.
The internal parts of the pump used in the machine are suitable for use with most carpet cleaning chemicals.
But they are susceptible to chemical attack from some cleaning substances, such as hydrocarbon solvents and chlorinated bleaches. These non-compatible materials are not of the type used for carpet cleaning.
Chemicals
Suitable Chemicals
• Alkalis
• Detergents
• Hydroxides
• Soaps
• Vinegar
Non-Compatible
• Aldehydes
• Aromatics Hydrocarbons
• SP Butyls
• Carbon Tetrachloride
• Clorox*
• Chlorinated Bleaches
• Chlorinated Hydrocarbons
• Lysol*
• Methyl Ethel Ketone (MEK)
• Perchorethylene (perc)
• Phenolics
• Trichlorethylene
• D-Limonene
Do not let pump run unattended.
*Registered Trademark
86399150 Operators Manual - Dominator 500 PSI 17 Gallon 11
Operations
Pre-Run Inspection
1.
Check all fittings and connectors for proper assembly.
2.
Check all hoses for leaks. Repair or replace any damaged hoses.
3.
Check power cord(s) for any damage. If damaged, replace.
Equipment Set-up
1.
Plug power cord from machine into properly grounded wall outlet.
2.
Turn vacuum motor switch on and off to make sure there is electrical power at machine.
3.
Using a clean container, fill the solution tank with clean hot water. Do not use water over 130°F. Mix in a non-foaming cleaning concentrate for use in hot water extraction machines, following the manufacturer's instructions printed on container.
4.
Connect priming hose to solution fitting on machine. Turn on pump and run for 30 seconds or until a steady flow of water is coming out of priming hose. Turn off pump and disconnect priming hose.
5.
Connect vacuum hose to machine. Slide the swivel cuff over the outlet on the tank.
6.
Connect the hose to your machine and wand. Pull back the knurled collar on the quick disconnect coupler and push onto the connection on the chassis. To avoid leaks, check to be that a positive connection was made.
NOTE: When using a powder cleaner, pre-mix with hot water in a clean container before adding to the solution tank.
7.
Turn pump and vacuum switch(es) to the on position.
Heater Operation
NOTE: Units with Heat Only
The solution fittings on the machine will become extremely hot during operation. Allow sufficient time to cool, or run solution through the machine with the heater turned off before disconnecting or performing any maintenance on the heater.
Plug the two power cords into separate grounded circuits. The heater draws 15 amps of current.
Turn the solution pump ON. Fully prime the solution system before turning heater on.
Turn the heater switch on. The red light on the heater switch will be on when the heater switch is on. The red heater temperature light will be on when the heater is active and will turn off when the heater reaches maximum temperature.
On initial start-up the heater will take a few minutes to reach operating temperature.
When turning the pump and heater OFF, make certain that you turn the heater off FIRST.
12 86399150 Operators Manual - Dominator 500 PSI 17 Gallon
Cleaning
Always use defoamer if foaming occurs. Foam will suspend large particles that may damage vacuum(s) as well as allow liquid into the vacuum motor(s) without activating the float shutoff.
1.
Prior to cleaning, make certain that the nozzle is functioning properly.
a.
To check, hold the wand about one foot above the surface to be cleaned and open the wand valve. A full spray should be observed from the nozzle.
b.
If the nozzle is not showing a full spray pattern, adjust nozzle for proper pattern, clean, or replace nozzle.
2.
Normally, chemical is applied on the push stroke of the wand when cleaning. Vacuuming is done on the pull stroke. For heavily soiled carpets the wand may be used in a scrubbing manner, applying chemical in both the push and pull stroke.
3.
When cleaning, keep the working opening (wand mouth) flat on the surface being cleaned. Keep the wand moving when the valve is open.
4.
The shutoff float inside the vacuum tank will impede the vacuum flow when the vacuum tank is full. When this occurs, empty the vacuum tank by opening the dump valve and dispose of the waste in a proper manner.
5.
Once the vacuum tank has been emptied, you may once again proceed with cleaning
Operations
86399150 Operators Manual - Dominator 500 PSI 17 Gallon 13
Maintenance
Periodic Maintenance
Twice a month, flush a white vinegar solution (one quart vinegar to two gallons of water) or anti-browning solution (mixed as directed) through the machine. This will prevent build-up of alkaline residue in the system.
Periodically inspect all hoses, electrical cables and connections on your machine. Frayed or cracked hoses should be repaired or replaced to eliminate vacuum or solution pressure loss. The electrical cable must be well insulated and cable connector screw kept tight. If the cable insulation is broken or frayed, repair or replace immediately. Don't take chances with electrical fire or shock.
Daily/Regular Maintenance
Before making any repairs or adjustments to the machine, disconnect the power cords from the
electrical source.
1.
Empty unused cleaning solution from the solution tank.
2.
Inspect and clean filter screen in solution tank.
3.
Flush pumping system with 1 to 2 gallons of clean water.
4.
After each use, rinse tank with fresh water. Periodically inspect the recovery tank and decontaminate if necessary, using a Hospital Grade Virucide or a
10-1 bleach to water solution. Waste water should be disposed of properly.
Do not allow machine to freeze.
SERVICE SCHEDULE
Check machine for cord damage
Check recovery dome and gasket for damage and cleanliness
Check hoses for wear, blockages, or damage
Check handles, switches, and knobs for damage
Run one gallon of water through solution system
Clean out recovery tank and check float valve to make sure it moves freely
Clean out solution tank and remove and clean vacuum intake screen
Clean outside of all tanks and check for damage
Run vac motor for at least one minute to allow motor to dry
Store with dome off tank to allow the tank to dry
Check all gaskets for wear and leakage
Check pump pressure; observe spray pattern and check with gauge if necessary
Check and clean solution screen
Check cables for fraying
Check overall performance of machine
Check vac motor carbon brushes
DAILY WEEKLY QUARTERLY
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
14 86399150 Operators Manual - Dominator 500 PSI 17 Gallon
Only qualified maintenance personnel are to perform the following repairs.
Vacuum Motor Replacement
1.
Turn off all switches and unplug machine.
2.
Remove hardware under front of machine to access component compartment.
3.
Remove vacuum motor cover and disconnect motor wires.
4.
Remove the vacuum motor.
5.
Reverse process to install vacuum motor.
Maintenance
Vacuum Motor Carbon Brushes Replacement
End Cap
Carbon
Brushes
WARNING: The green ground wire must be attached for safe operation. See wiring diagram.
If armature commutator is grooved, extremely pitted or not concentric, the motor will need to be replaced or sent to a qualified service center.
Important:
These brushes wear quicker as the length shortens due to increased heat. Spring inside brush housing will damage motor if brushes are allowed to wear away completely.
3
8
[9.5mm]
Periodically check the length of the carbon brushes.
Replace both carbon brushes when either is less than
3/8" (9.5mm) long.
86399150 Operators Manual - Dominator 500 PSI 17 Gallon 15
Operations
Solution Pump Replacement
Only qualified maintenance personnel are to perform the following repairs.
Pump Replacement Kits
500 psi
Cam & Bearing Kit
86201040
Plunger & Seals Kit
86201080
Valve & O-Rings Kit
(both sides)
86201030
16 86399150 Operators Manual - Dominator 500 PSI 17 Gallon
Only qualified maintenance personnel are to perform the following repairs.
Pressure Regulator
For best results with the pressure regulator, we recommend that you clean and lubricate the piston and u-cup with Superlube lubricant monthly or when pressure drop seems excessive.
1.
Turn unit off before lubricating.
2.
Remove cap, spring and spring retainer plate.
3.
With fingertips remove piston and u-cup.
4.
Wipe piston and u-cup clean of any film or scale.
5.
Lubricate the piston and u-cup with Superlube.
6.
Reassemble regulator.
7.
With pump ON, re-adjust pressure regulator for normal operation.
Lubricate U-Cup with Superlube Monthly.
REBUILD KIT
8.619-924.0
(GREEN 500 PSI)
Operations
86399150 Operators Manual - Dominator 500 PSI 17 Gallon 17
Maintenance
Troubleshooting
PROBLEM
Loss of Power
Electrical shock
Vac motor speed varies or doesn't run
Loss of vacuum
Pump runs no solution
Pump runs, loss of pressure
Pump will not run
Solution hose fitting hard to connect
Carpet not getting clean
Carpet too wet
Carpet browning
Solution not flowing properly
CAUSE
Unit not plugged in
Dead electrical circuit
Faulty power cord
Receptacle not grounded
Internal wiring problem
SOLUTION
Connect unit to 3 prong grounded outlet.
Check building circuit breaker or fuse box.
Replace
Contact an electrician to check building's wiring
Have a trained service technician check machine's wiring
Vacuum circuit breaker tripped
Faulty vacuum motor
Faulty switch
Loose vacuum dome
Crack in dome of poor joint
Reset Breaker
Replace
Replace
Center and seal dome over tank
Replace or repair using acrylic plastic cement only
Lint or dirt clogging vacuum screen
Loose cuffs on vacuum hose
Vac motor seals leaking
Floor tool vac chamber clogged
With power off clean screen
Tighten cuffs turning counterclockwise
Replace
Wash out with hose. Pick lint out with a wire
Replace Vacuum hose damaged
Recovery tank full / Float ball stuck in the up position
Pump inlet screen plugged
Pump not primed
Turn off power, drain recovery tank.
Clean inlet screen
Prime pump with priming hose
Internal or external solution line damaged and leaking
Replace
Internal pump components wearing out Replace, see pump kit components
Check valves in pump head for particles or cuts in seals
Take piston from BPR and lubricate with Superlube. If problem still exists change BPR kit
Faulty switch
Loose wiring
Replace
Repair or replace
Corrosion on fittings.
Severe soil conditions
Over saturation
Leaving carpet too wet
Too much chemical
Solution hose connection
Faulty pump
Faulty floor tool valve / Nozzle
Faulty pump switch
Clean with steel wool. Soak in acetic acid (white vinegar). Lubricate lightly with silicone base lubricant.
Make several passes at right angles to each other. Use a pre-spray.
Adjust solution pressure to lower settings. Make several passes without spray
Check for loss of vac pressure
Check label for correct solution concentration
Check for positive connection
Repair or replace
Repair or replace
Repair
18 86399150 Operators Manual - Dominator 500 PSI 17 Gallon
Notes
86399150 Operators Manual - Dominator 500 PSI 17 Gallon 19
Suggested Spare Parts
86334490 DECK PLATE
86007970 STRAINER
86199430 CASTOR
86135320 BRUSH SET
VACUUM
86010730 WASHER
86309790 WHEEL
86001660 HUBCAP SHAFT
86300070 HUBCAP
86201030 VALVE & O-RINGS KIT
86201040 CAM & BEARING KIT
PUMP
20 86399150 Operators Manual - Dominator 500 PSI 17 Gallon
Notes
86399150 Operators Manual - Dominator 500 PSI 17 Gallon 21

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- 500 psi pump pressure
- 17 gallon solution capacity
- 14 gallon recovery capacity
- Dual 2 stage vacuum motor
- Heater
- Commercial grade