DC/DC CONVERTER

MODEL

VTC305MS SERIES

STEP-UP CONVERTER

Benefits

• Ultra-Quiet

• Power sensitive electronics without interference

• Rugged & Reliable

• Ensure years of safe and trouble free operation

Design Features

• Vibration proof output voltage adjustment by 3 position DIP switch

• Audible & visual indicators for constant current, low input voltage, low output voltage & over-temperature

• Extremely rugged and well suited for marine and other demanding environments

• High tolerance for shock and vibration

• Ultra-quiet low EMI operation

• Current limiting protection

• Reverse input protection

• Output over-voltage crowbar

• Dry contact output fail relay

• Remote control option

• Wide-Temperature operation

• Parallel output diodes available

• Conformal Coating and Harsh Environment Ruggedized

• 2 years parts and labour warranty

Description

Step up a 12 VDC battery to between 13.5 and 17.0 or 24.0 and 27.5

VDC in 0.5 VDC increments (via 3 position DIP switch), or stabilize a

12 or 24 VDC power system.

Military Option

Most of the products manufactured by Analytic Systems can be adapted for military use (Commercial Off The Shelf).

Safety features include reverse input protection, low input voltage alarm, low output voltage alarm, over temperature shutdown and alarm, a dry contact alarm relay output and output overvoltage crowbar. If the input voltage exceeds the regulated output voltage, the unit simply passes the voltage through with full LC filtering and a single schottky diode drop (0.5 VDC or less). Optional features include remote panel monitoring with On/Off control.

We provide four different levels of ruggedization; most often, a product in military use will use the extra-wide temperature range components to allow operation from -40°C to +55°C.

The printed circuit boards are also protected against condensation and are enhanced with vibration protection that meets or exceeds

MIL-STD810F, Method 514-3 and Cat-1 Proc 1.

C.O.T.S. products are designed to meet various levels of EMC radiated and conducted emissions MIL-STD 461F.

Applications include temporarily brightening 12 volt headlights or work lights, increasing voltage into an automotive or marine ignition system for hotter spark and/or prevention of failures due to voltage drop during engine start, stabilizing 12V and 24 VDC power systems in marine, automotive or aeronautical environments and more.

All C.O.T.S. products are manufactured in accordance with IPC-A-610.

Applications: Military, Electric Utilities, Substations, Base Station Power,

Industrial Controls and OEM Applications.

An ISO9001 and AS9100 Registered Company Battery Chargers • Inverters • Power Supplies • Voltage Converters

8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 800.668.3884 (US/CANADA)

www.analyticsystems.com

DC/DC

CONVERTER

Electrical (Input)

Input Volts (DC)

Input Amps (max)

Input Fuse (AGC)

Noise on Input

Low Input Voltage Alarm

Current Limit

Electrical (Output)

Output Nominal (op)

Output Volts (DC)

Output Current (Amps)

Output Crowbar

Output Ripple & Noise

Low Output Voltage Alarm

Transient Response

Regulation (Line & Load)

Duty Cycle

Efficiency

Environment Specification

Operating Temp. Range

MODEL

VTC305MS SERIES STEP-UP CONVERTER

10.5-18

30

20 x 2 Amp

< 25 mV

10.5 VDC

30 Amps in

10.5-28

12

Input - 1V or 13.5 to 17.0

Whichever is greater

* 27

Programmed Output Volts x 1.2

< 25 mV

Programmed Output Voltage minus 2.5 VDC

24

Input - 1V or 24.0 to 27.5

Whichever is greater

< 1V for 50% Surge

< +/- 0.5%

Continuous 100% for 24 hrs per day

> 90% @ Maximum Output

Humidity

Audible Noise

Typical Service Life

Isolation

Mechanical Specification

Length

Width

Height

Material

Finish

Fastenings

Weight

Connections

Warranty

-40°C to +55°C @ maximum output

Derate Linearly 2.5% per °C from 55°C

0 - 95% Relative Humidity (non-condensing)

NONE Ødb @ 3 ft

> 10 yrs. (87,600 hrs)

Any Input or Output to Case 500 VDC

Input to Output – Common Negative

9.1 in / 23.1 cm

7.8 in / 19.8 cm

2.5 in / 6.4 cm

Marine Grade Aluminium

Black Anodize / Powder Epoxy Coat

All 18-8 Stainless Steel

4.0 lb / 1.8 kg

Four contact output terminals

2 years

*The actual output current capability depends upon the input/output voltage ratio. To obtain the actual output current capability at any given input voltage, use the following formula:

Output Amps = Input Volts/Output Volts x 2

For example, at 11 VDC in and 13.6 VDC out, the output current = 11/13.6 x 27 = 22.8 amps

Note: Specifications are subject to change without notice.

An ISO9001 and AS9100 Registered Company Battery Chargers • Inverters • Power Supplies • Voltage Converters

8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 800.668.3884 (US/CANADA)

www.analyticsystems.com

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement