TM DMP Virtual Keypad App We make your company valuable MORE NOW, with Video Verification SCHEDULES ACCESS CAMERAS ARMED ALL ALARM NOTIFICATION LOCKDOWN/A OUTPUTS USER SETTINGS THERMOSTATS UPGRADE YOUR IMAGE! Introducing the all-new line of SecureCom Video Cameras suitable for both commercial and residential applications. For more information go to dmp.com/Video © 2015 Digital Monitoring Products LT - 0898 10/15 C TO LIC TU K C R N OR PA NE GE R fall 2015 ORDER ONLINE buy.dmp.com The DMP website offers the information to answer any question you may have. Search through our complete document library, read current press releases, view DMP product approval listings and place orders online. ORDER BY PHONE DMP INFORMATION • CALL TOLL FREE CUSTOMER SERVICE - 866-266-2826 Or you can order by email [email protected] INSIDE SALES - 877-757-4367 • [email protected] C O R P O R AT E O F F I C E 417-831-9362 TECHNICAL SUPPORT CALL TOLL FREE 888-4DMPTEC (888-436-7832) [email protected] FOLLOW D M P Search DMPAlarms ELECTRONIC FUNDS TRANSFER This convenient service not only saves you money on the expense of checks and postage, but more importantly, it saves you valuable time. Banks, insurance companies, State and Federal governments, and large corporations save millions annually by using EFT. You can enjoy free domestic ground freight if you sign up for EFT. Ask Accounts Receivable for more details. FREE FREIGHT Dealers who qualify can receive Free Domestic Ground Freight on any orders over $1,500.00. For more information about this exciting program, contact your Dealer Development Manager or Customer Service. SPONSORS HID Global...................................................................... 92 Tane Alarm Products.................................................... 123 Nortek.......................................................................... 127 Kwikset......................................................................... 133 3 FAX: 800.743.5724 CUSTOMER SERVICE: 866.266.2826 4 TABLE OF CONTENTS Let us help promote YOUR business! SPECIFICATION SHEETS In today’s economy marketing may be the edge you need to jumpstart your business. And with the DMP Dealer Marketing Support Program you have the customizable tools at a fraction of traditional costs to promote your business! DMP offers: • BROCHURES • DOOR HANGERS • ADS • AND VIDEOS ...all customizable for our dealers with YOUR company logo, YOUR profile, YOUR photos and YOUR contact information. Residential and commercial brochures in both full page and tri-fold sizes. Virtual Keypad™ app die cut brochure XTL Series .....................................................................................................6 XT Series ......................................................................................................10 XR150 Series ...............................................................................................16 XR550 Series ...............................................................................................20 263C/263H ....................................................................................................26 XR150FC/XR550FC .....................................................................................30 Digital Cellular Communicators ..............................................................34 CellComSL....................................................................................................38 Thinline Series Keypads ...........................................................................40 Graphic Touchscreen Keypads ...............................................................44 734N/734N-WiFi .........................................................................................48 1100 Series Wireless Receivers ..............................................................50 1100 Series Wireless Transmitter ..........................................................52 1100 Series Wireless Life Safety Devices .............................................56 Mobile Platforms ........................................................................................58 MyVirtualKeypad.com................................................................................62 738Z Z-Wave® .............................................................................................66 Video Products ...........................................................................................70 Entré..............................................................................................................72 SCS-1R .........................................................................................................78 SCS-VR .........................................................................................................80 SYSTEM DESIGN XT Series ......................................................................................................14 XR550 Series................................................................................................24 Entré..............................................................................................................76 PRODUCTS Control Panels Panels......................................................................................................83 Enclosures..............................................................................................84 Packages and Kits.................................................................................88 Access Control Credentials..............................................................................................89 Accessories............................................................................................90 Readers...................................................................................................91 Software..................................................................................................93 Keypads Wireless Series......................................................................................94 Aqualite Series.......................................................................................95 Thinline Series.......................................................................................96 Designer™ Series...................................................................................98 Icon Series..............................................................................................99 Graphic Touchscreen Series...............................................................99 Fire Command Series....................................................................... 100 Accessories......................................................................................... 100 Modules and Expansion Auxiliary Modules............................................................................... 103 Expansion Modules............................................................................ 105 Power Supplies Batteries............................................................................................... 108 Power Supplies................................................................................... 109 Transformers...................................................................................... 109 Fire Devices Detectors.............................................................................................. 111 Pull Stations......................................................................................... 112 Intrusion Devices Accessories......................................................................................... 114 Bank/Vault Detectors......................................................................... 119 Contacts................................................................................................ 119 Glassbreak Detectors........................................................................ 122 Panic/Holdup Detectors.................................................................... 122 PIR Detectors....................................................................................... 124 Wireless Products 1100 Series.......................................................................................... 125 Z-Wave® Products.............................................................................. 132 Cameras............................................................................................... 134 Central Station Products Receiver Products.............................................................................. 135 Software............................................................................................... 137 Communication Products Network Communication.................................................................. 139 Cellular Communication.................................................................... 139 CellComSL........................................................................................... 141 Promotional/Literature Promotional Items.............................................................................. 143 Sales Literature.................................................................................. 144 Training................................................................................................ 149 CHARTS/REFERENCE Feature Comparison................................................................................ 150 Product Compatibility.............................................................................. 152 Terms and Conditions............................................................................. 154 Index........................................................................................................... 156 Canvas neighborhoods with unique customized door hangers. Professional quality videos for both residential and commercial customers. 5 Give us a call to get your marketing jump started! 800-641-4282. E-mail us via [email protected] or visit our website www.dmp.com/dealerdirect, on custom marketing support tab. FAX: click 800.743.5724 CUSTOMER SERVICE: 866.266.2826 6 WIRELESS INTRUSION PANELS XTL SERIES RECEIVER 1 & 2 OPERATION Select one or two receivers for messages regarding alarms, supervisory/trouble, opening/ closing, and test reports. Send all messages to both receivers or identify one receiver for alarms and second for reports or trouble messages to alert only the proper responder. IT’S SIMPLY FASTER TO INSTALL This compact panel is perfect for residential and small commercial installations ON-BOARD CELLULAR, NETWORK, OR WIFI COMMUNICATION The XTLC works on CDMA data networks in the USA. Cellular connections can’t be cut, providing greater security than traditional land-line dial-up connections. Cellular transmission is a great solution for installation sites without a land line or currently using VOIP lines. XTL SERIES SPEC Place Your Logo Here Actual • • • • • • Size Designed for fast, reliable installations Increase your RMR with cellular, network, or WiFi communication 28 wireless zones with pre-named zones Supports up to 8 two-way wireless key fobs or two-way wireless outputs Supports 4 fully functional two-way wireless keypads Supports fully functional two-way wireless sirens XTLC/XTLN/XTLN-WIFI™ WIRELESS BURGLARY CONTROL PANEL SYSTEM FEATURES • XTLC - CDMA Technology uses Cellular Services from SecureCom Wireless • XTLN & XTLN-WIFI offer network connectivity • Plastic enclosure can be easily wall mounted or located on a shelf and can be customized with your logo printed on the light pipe • Supports up to four two-way wireless LCD 9000 Series keypads • Arm only, ambush code, and temporary user code options • Built-in standby battery • Selectable automatic arming and disarming • Remote control via MyAccess™ & DMP App • Open/Close schedules with Closing Check • All/Perimeter, Home/Sleep/Away or Area system • 30 user codes with authority levels • 100-event memory 7 FAX: 800.743.5724 DIRECT DATA TRANSMISSION The digital cellular communicators transmit IP data packets directly from the panel over the CDMA wireless data network. All of the messages being sent by the control panel are received directly by the DMP Central Station receiver. There is no retransmission or reinterpretation of the information. Direct reporting means faster response, with no concerns about signals not being properly relayed or intermediate communication links failing. FULLY SUPERVISED You’re kept fully informed of system status. The unit sends full reporting messages including Zones, Areas, and Users, with all names and details included. Full supervision ensures that the cellular communication path is intact and functional. ONE-STOP CELLULAR SecureCom Wireless provides a reliable wireless solution for the XTL’s transmission of alarm signals to the Central Station receiver. • Built-in English text programming from any LCD keypad • Provides recurring revenue opportunities • EASYconnect™ connection for the Virtual Keypad™ App when used with a network connection The XTLN control panel includes a builtin network communicator for the fastest and most secure alarm communication available. XTLN-WiFi includes built-in network WiFi communication to provide you with all the options you may need. • Late to Open/Early to Close and Traffic Count features for retail installations • Attrition Detection™ monitors system for arming activity • Programmable User Inactivity Monitor watches for on-site activity • Remote program/download with Remote Link™ over cell, network, or WiFi using SecureCom Wireless TECHNOLOGY EASYconnect enables the control panel to establish an outbound connection to SecureCom over the network. This allows for an effortless installation of network panels, without any customer router programming, providing extremely quick App connection times. SIMPLE ARMING XTL provides multiple arming configurations: Area arming with six separate areas; All/ Perimeter arming with perimeter and interior areas; or Home/Sleep/Away arming with perimeter, interior, and bedroom areas. Users can arm the perimeter and interior at night while leaving the bedroom area disarmed. REMOTE CONTROL VIA MYACCESS: SMS MESSAGING DMP MyAccess lets users send commands via text messages to their panel. Residential and smaller commercial users can now remotely control their systems, including the ability to arm or disarm their system, control outputs, retrieve system status, and perform other functions. Each command received by the panel is acknowledged back to the user via return SMS Message. CHECK SYSTEM STATUS Users can be informed of alarm system activity and status. The panel transmits text messages regarding alarms, troubles, and arming/disarming events. SMS messages can be directed to as many as three cell phone numbers. Messaging can be configured via Remote Link™ or from the keypad. VIRTUAL KEYPAD™ APP The DMP App provides users with the ability to access a number of system functions remotely via a cellular or internet connection. As a dealer, the App provides the opportunity to brand it using your company logo. • At a glance, check system status including programmed areas. • Arm or disarm the system in an instant • Tap any programmed outputs to turn them on or off. • Adjust lighting/thermostats/locks. • Video capability - up to 6 cameras, remote viewing. • View, add, edit, and delete system schedules for arming/disarming and favorites, outputs, and doors • Users can click on the Alarm Push Notification and open the App to view a list of available camera views, giving them the ability to verify the alarm based on the video clips and live thumbnails. • Users can watch real time device activation when clicking on hotspots embedded in the associated video stream with Rooms with a View MYVIRTUALKEYPAD.COM Users can access their security system via internet connection on a tablet or computer. Customers log into myvirtualkeypad.com with their login and system user code. ON-BOARD WIRELESS The XTL Control Panel includes a Wireless Receiver on-board supporting the 1100 Series wireless devices. These 900MHz frequency-hopping, spread-spectrum devices feature two-way communication for superior operation, supervision, and battery life. Two-way communication minimizes repetitive signaling and helps to quickly identify missing transmitters. With 28 wireless zones the transmitter options are more than sufficient for most installs. The industry’s only PIRs that are configurable over the air, 8 key fob zones or 8 wireless outputs including arm/alarm LED, wireless sirens, and wireless relays make the XTL a perfect choice for residential or small commercial applications. 1135 WIRELESS SIRENS The 1135 Wireless Siren Series makes it possible to quickly and easily place one or more sirens as part of an installation. With both residential and commercial end users, this battery powered siren is an easy, add-on sale to customers who want the extra security provided by locating sirens in several interior locations. The 1135 includes a cover tamper and survey LED, and comes with batteries. The 1135 has a volume of 100 dB, while the 1135dB offers 110 dB. CUSTOMER SERVICE: 866.266.2826 8 WIRELESS INTRUSION PANELS 9000 SERIES WIRELESS KEYPAD The 9060 and 9063 Wireless Keypads are fully functioning, supervised keypads that provide installation flexibility. These full-feature keypads include four 2-button panic keys and an internal speaker. The backlit keyboard is easy to read, and both the keyboard and logo turn Red in alarm conditions, providing a visual alert. Both Keypads have a 32-character display, and can be programmed with a 16-character home or business name. The 9063 keypad also includes a built-in proximity reader for codeless arming and disarming. BUILT-IN PROGRAMMER An internal English-text programmer enables technicians to easily program and test the panel from any keypad. A lockout code restricts access to only authorized persons. KEYPAD SHORTCUT KEYS Keypad shortcut keys simplify operation and allow the user to more quickly arm, check in, monitor, exit, or reset the system. One-button arming creates the simplest keypad operation available. Use the one-button shortcut keys for common functions or use the ATM style menu for advanced functions, whichever method meets the user’s needs or level of expertise with the system. USER CODES Program up to 30 codes. Assign a Standard or Master Authority level to control each user’s level of access to the system, with scheduled and limited users. ATTRITION DETECTION™ PROMPTS YOU TO CALL YOUR CUSTOMER FALSE ALARM FEATURES Providing end users with a way to reduce false alarms, both Cancel/Verify™ and the False Alarm Question features prompt end users to validate whether an alarm has occurred after entering their code. In a Home/Sleep/Away or All/Perimeter system, the user can either press VERIFY or YES to manually confirm a valid burglar alarm and an alarm is then sent to the Central Station. HOME/SLEEP/AWAY For residential applications, the homeowner can press one button to select each of three separate system arming options. They can select HOME to arm the perimeter of the home, but allow for movement within the house. Select SLEEP to arm the perimeter and only specified areas inside their home, leaving sensors near bedrooms disarmed. Selecting AWAY fully arms all elements of the system. ALL/PERIMETER In business applications, system users can quickly select ALL to completely arm the system as they leave the facility for the day. They also have the option to select PERIMETER, arming all exterior sensors at doors and windows, but disarming all interior sensors so employees can move freely around the facility. 9 The exclusive DMP Attrition Detection feature gives you advance warning that a customer may be preparing to cancel their monitoring contract. With this feature activated, you will receive a notification if there has been no system activity for the number of days you select. CROSS ZONING This powerful, false-alarm-reduction feature allows zones to be cross-zoned and report alarms only when two or more zones fault within a programmable time of 4 to 250 seconds. Should just one zone trip, only a zone fault report is sent to the Central Station. EVENT MEMORY The XTL panel logs up to 100 user and system events that you can view at any time through a keypad User Menu option. The Display Events feature allows users to view stored events such as openings and closings, zone events, user code changes, and supervisory events. FAX: 800.743.5724 ZONE INACTIVITY With Zone Inactivity, you can easily monitor a person living alone. If there is no activity at the premises within the programmed number of hours, the system transmits an SMS message to your PDA and/or cell phone. The Central Station also receives an alert. It’s a valuable feature for customers looking after aging adults. ZONE AUDIT The Zone Audit feature allows programming the panel to send an alert when the sensor fails to trip within the specified number of days. This feature helps identify potential sensor problems, including sensors deactivated to bypass faults or blocked sensors. WIRELESS KEYPAD ASSOCIATION KEYPADS COMPUTER SOFTWARE 9060-W Wireless Keypad 9060-W/699 Wireless Keypad with Deskstand 9063-W Wireless Keypad with Prox Reader 9063-W/699 Wireless Keypad with Prox Reader and Deskstand 9862-W Wireless Touchscreen 699 Keypad Deskstand DMP WIRELESS Remote Link Programming Software System Link End-User Management Software Link Server Application MOBILE APPLICATIONS Virtual Keypay™ App MyAccess™ MyVirtualKeypad.com CENTRAL STATION RECEIVERS SCS-1R SCS-VR Security Control Receiver Software Receiver XTLN XTLC This is a great time-saver for installers. Any keypads not associated with another panel are accepted and assigned to the first open keypad address available. Keypads are automatically assigned based upon the order in which they are detected. A maximum of four keypads may be associated with a panel. REMOTE PROGRAMMING Remotely program panels using DMP Remote Link software. Upload panel programming, make the necessary programming change, and then download the revised programming into the panel. FOR RETAIL INSTALLATIONS The Late to Open/Early to Close feature sends a message to the Central Station if the facility isn’t opened on time or closed before the scheduled time. The Traffic Count sends a daily tally of trips for the specified zone. With the Receiver 1 & 2 operation, Auxiliary 1 & 2 Zone messages can be sent to a specific receiver, enabling retail clients to alert a specific guard station of potential shoplifting in a certain area or other type of notifications. POWERING THE PANEL The panel is powered by a small 12V plugin power supply with standby battery operation. XTLN-WIFI 1100R 1101 Repeater Universal Transmitter Internal and External Contacts 1102 Universal Transmitter External Contact 1103 Universal Transmitter Internal and External Contacts 1106 Universal Transmitter Internal and External Contacts 1107 Micro Window Transmitter 1114 Four-Zone Expander 1116 Relay Output 1117 LED Annunciator 1119 Door Sounder 1121 Pet Immune PIR Motion Detector 1126R 360 Ceiling Mount PIR 1127C Wall Mount Curtain PIR 1127W Wall Mount Wide Angle PIR 1129 Glassbreak Detector 1131 Recessed Contact 1135 Siren 1137 LED Emergency Light 1135DB Siren 1139 Bill Trap 1141 Wall Button 1142 Two-Button Hold-up Transmitter 1142BC Two-Button Belt Clip Hold-up Transmitter 1145-4-B Four-Button Key Fob 1145-2-B Two-Button Key Fob 1145-1-B One-Button Key Fob 1148 Personal Pendant 1161 Smoke with Sounder 1162 Smoke and Heat Detector 1164 Smoke Detector with Synchronized Sounder 1165 Commercial Smoke Detector 1183-135F Heat Detector 1183-135R Heat Detector 1184 Carbon Monoxide Detector 738Z Z-Wave Module LISTINGS AND APPROVALS ETL (All Models) ANSI/UL 1023 Household Burglar ANSI/UL 985 Household Fire Warning ANSI/UL 1610 Central Station Burglar California State Fire Marshal (CSFM) FCC Cellular Listings FCC ID: MIVCNN0301 (XTLC Only) Industry Canada: 4160A-CNN0301 (XTLC Only) FCC WiFi Listings FCC ID: XM5-SMD2144SMT Industry Canada: 8516A-SM2144SMT FCC Wireless Listings FCC ID: CCKPC0117 Industry Canada: 5251A-PC0117. Underwriters Laboratories (UL) Listed (XTLN/XTLN-WIFI) ANSI/UL 1023 Household Burglar ANSI/UL 985 Household Fire Warning ANSI/UL 1610 Central Station Burglar For additional information, access www.dmp.com and select Compliance. SYSTEM SPECIFICATIONS Primary Power 12 VDC (Model 372-500) Secondary Power 3.7 VDC lion Polymer Battery Enclosure ABS Plastic Dimensions: 5.5” W x 3.75” H x 1” D CUSTOMER SERVICE: 866.266.2826 10 INTRUSION PANELS XT SERIES RECEIVER 1 & 2 OPERATION ONE PANEL OFFERS EVERYTHINGYOU WANT — Two-way Wireless Receiver, along with Network, Cellular, and Dialer Communications Select one or two receivers via Network, Cellular or Dialer for messages regarding Alarms, Supervisory/Trouble, Opening/Closing, and Test Reports. Send all messages to both receivers, or identify one receiver for alarms and second for trouble messages to alert only the proper responder. FLEXIBILITY WHEN ORDERING This extremely powerful panel is highly customizable, giving you the flexibility to tailor the panel in a configuration that meets the needs of both you and your customer. You get many of the features and technology expected in a larger panel with all of the quality and innovation you expect from DMP. • Choose your preferred configuration for communications: Network and/or Dialer, both on-board • On-Board Wireless Receiver (XT50) • Add technology later to expand capabilities, including wireless or cellular (CDMA, or HSPA+) XT SERIES SPEC • XT30 supports 10 hard-wired on-board zones and 28 expansion zones — wireless (with 1100D Series) or hard-wired XT30/XT50 comes mounted inside your choice of a small or medium gray enclosure • XT50 supports 10 hard-wired on-board zones, and up to 28 hard-wired zones. Up to 28 wireless expansion zones when using an external 1100 Series receiver. 48 wireless expansion zones when using the on-board wireless receiver. XT SERIES™ — BURGLARY/FIRE/DOOR ACCESS CONTROL PANELS SYSTEM FEATURES • DMP Network and Cellular Communications • 16-character zone, user, and area names • MyAccess - Remote control via SMS messaging • 100-event (XT30) or 200-event (XT50) memory ™ • Virtual Keypad App - Compatible with Apple and Android smartphones and tablets. ™ ® ® • Late to Open/Early to Close and Traffic Count features for retail installations • Door Access feature can be added with the 734 Wiegand module or DMP Thinline™ and Aqualite™ keypads with built-in proximity reader and relay. Codeless arming/disarming with proximity reader • Backward and forward compatibility with a variety of DMP products • Supports DMP LCD keypads including the Thinline, Aqualite, Icon, and 9000 Series wireless keypads • 500mA auxiliary output • 100mA switched smoke detector • Built-in English text programming from any LCD keypad • Eight keypad addresses • Open/Close schedules with Closing Check • 30 (XT30) / 99 (XT50) 4-digit user codes with authority levels • Attrition Detection™ monitors system for arming activity • All/Perimeter, Home/Sleep/Away or six Area System • User Check in allows you to monitor latchkey children • One two-wire smoke detector zone • Remote program/download with Remote Link™ • Arm only, ambush code, and temporary user code options • Programmable User Inactivity Monitor watches for on-site activity • Four on-board and eight wireless outputs for annunciation and control applications • EASYconnect™ connection for the Virtual Keypad™ App when used with a network connection 11 FAX: 800.743.5724 Factory-configurable options give you the freedom to order the panels to match your system and customer requirements with dialer, network, and cellular connection options. Knowing in advance what options you require saves time and money, helping make this the most affordable allin-one security control panel available! The XT Series also offers the freedom to add on a cellular module or connect a wireless receiver and devices to the panel at a later date. ™ COMMUNICATION FLEXIBILITY IN PROGRAMMING As the industry’s first all-in-one control panel, the XT Series enables you to program up to three different communication paths, including digital dialer, on-board 10/100 Ethernet, or cellular communication to a SCS-1R or SCS-VR Receiver. This provides one primary path and up to two backup communication paths, using the same proven technology that secures countless banks and other high-security applications. For added flexibility, the Receiver 1 & 2 Operation feature allows specific messages to be transmitted to one of two receivers, or both. REMOTE CONTROL VIA MYACCESS: SMS MESSAGING DMP MyAccess lets users send commands via text messages to their panel. Residential and smaller commercial users can now remotely control their systems, including the ability to arm or disarm their system, control outputs, retrieve system status, and perform other functions. Each command received by the panel is acknowledged back to the user via return SMS Message. VIRTUAL KEYPAD™ APP The DMP App provides users with the ability to access a number of system functions remotely via a cellular or internet connection. As a dealer, the App provides the opportunity to brand it using your company logo. • At a glance, check system status including programmed areas. • Arm or disarm the system in an instant • Tap any programmed outputs to turn them on or off. • Adjust lighting/thermostats/locks. • Video capability - up to 6 cameras, remote viewing. • View, add, edit, and delete system schedules for arming/disarming and favorites, outputs, and doors • Users can click on the Alarm Push Notification and open the App to view a list of available camera views, giving them the ability to verify the alarm based on the video clips and live thumbnails. ON-BOARD WIRELESS The XT50 Control Panel offers an 1100 Series Wireless Receiver on-board, supporting 1100 Series Wireless devices. The 900MHz frequency-hopping spread-spectrum 1100 Series wireless features two-way communication for superior operation, supervision, and battery life. Two-way communication minimizes repetitive signaling and helps to quickly identify missing transmitters. Simple keypad access can be used to verify that wireless device zones are in working order 1100 SERIES WIRELESS ADD-ON Add any 1100D Series Wireless Receiver for up to 28 wireless transmitters on the XT30 and up to 48 wireless transmitters on the XT50. 9000 SERIES WIRELESS KEYPAD The 9060 and 9063 Wireless Keypads are fully functioning, supervised keypads that provide installation flexibility. These fullfeature keypads include four 2-button panic keys and an internal speaker. The backlit keypad is easy to read, and both the keypad and logo turn Red in alarm conditions, providing a visual alert. Both keypads have a 32-character display, and can be programmed with a 16-character home or business name. The 9063 keypad also includes a built-in proximity reader for codeless arming and disarming. • Users can watch real time device activation when clicking on hotspots embedded in the associated video stream with Rooms with a View MYVIRTUALKEYPAD.COM Users can access their security system via internet connection on a tablet or computer. Customers log into myvirtualkeypad.com with their login and system user code. 263 SERIES CELLULAR ADD-ON Want to add Cellular later? Simply install the 263C or 263H Digital Cellular Communicator plug-on expansion card. There is no additional enclosure, power supply, battery, cabling, or conduit required. 263C CUSTOMER SERVICE: 866.266.2826 12 INTRUSION PANELS COMPATIBILITY USER CHECK IN Like all DMP products, the XT Series was designed to provide extensive backward and forward compatibility with DMP wired and wireless keypads, expansion modules, and software including Remote Link and System Link. SIMPLE ARMING XT Series panels provide multiple arming configurations: Area arming with six separate areas; All/Perimeter arming with perimeter and interior areas; or Home/ Sleep/Away arming with perimeter, interior, and bedroom areas. Users can arm the perimeter and interior at night while leaving the bedroom area disarmed. 7800/9800 GRAPHIC KEYPAD Provides Touchscreen control for all keypad functions. Slim profile in stylish gloss black or white finish with a 5 inch, full-color display. Your Logo Here With User Check in you can easily monitor latchkey children and know that they are safe at home, checked in by receiving an email/SMS message to your computer, PDA, or cell phone. USER CODES Program up to 30 user codes with the XT30, and 99 codes with the XT50 Series panels. Assign a Standard or Master Authority level to control each user’s level of access to the system. Additionally, the XT50 provides scheduled and limited users. ATTRITION DETECTION™ PROMPTS YOU TO CALL YOUR CUSTOMER The exclusive DMP Attrition Detection feature gives you advance warning that a customer may be preparing to cancel their monitoring contract. With this feature activated, you will receive a notification if there is no system activity for the number of days you select. CROSS ZONING This powerful, false-alarm-reduction feature allows multiple zones to be crosszoned and report alarms only when two or more zones fault within a programmable time of 4 to 250 seconds. Should just one zone trip, only a zone fault report is sent to the Central Station. 7800 Graphic Keypad FALSE ALARM FEATURES Providing end users with a way to reduce false alarms, both Cancel/Verify™ and the False Alarm Question features prompt end users to validate whether an alarm has occurred after entering their code. In a Home/Sleep/Away or All/Perimeter system, the user can either press VERIFY or YES to manually confirm a valid burglar alarm and an alarm is then sent to the Central Station. KEYPAD SHORTCUT KEYS Keypad shortcut keys are provided to simplify operation and allow the user to more quickly arm, check in, monitor, exit, or reset the system. One-button arming creates the simplest keypad available. Use the one-button shortcut keys for common functions. 13 EVENT MEMORY The XT30 logs up to 100 and the XT50 logs up to 200 user and system events that you can view at any time through a keypad User Menu option. The Display Events feature allows users to view stored events such as openings and closings, zone events, user code changes, and supervisory events. BUILT-IN PROGRAMMER An internal English-text programmer enables technicians to easily program and test the panel from any keypad. A lockout code restricts access to only authorized persons. PROGRAMMABLE OUTPUTS Four open collector outputs can be used for a variety of remote control and annunciation applications. Each output is rated for 50mA maximum. Add the Model 860 Relay Output module to provide four Form C relay contacts. FAX: 800.743.5724 ZONE INACTIVITY With Zone Inactivity, you can easily monitor a person living alone. If there is no activity at the premises within the programmed number of hours, the system transmits an email/SMS message to your computer, PDA, and/or cell phone. The Central Station also receives an alert. It’s the perfect companion for customers looking after aging adults. ZONE AUDIT The Zone Audit feature allows programming the panel to send an alert when the sensor fails to trip within the specified number of days. This feature helps identify potential sensor problems, including sensors deactivated to bypass faults. REMOTE PROGRAMMING Remotely program panels using DMP Remote Link software. Upload panel programming, make the necessary programming change, and then download the revised programming into the panel. DOOR ACCESS FEATURE Door Access can be added to any XT Series system by using a 734 Wiegand module or DMP Thinline or Aqualite keypad containing an on-board proximity reader and relay. These allow users to simply present their proximity credentials to the keypad to gain access to a protected area and provide system door control, arming, and disarming using proximity devices. KEYPADS 7000 7000A 7300 7800 9000 9800 Series Thinline Keypads Series Aqualite Keypads Series Icon Keypads Touchscreen Keypads Wireless Keypads Wireless Touchscreen Keypads EXPANSION MODULES 708 710 711 712-8 714 714-8 714-16 715 715-8 715-16 CELLULAR 263C 263H 380-400 381-12 381-25 383 387-1 387-2 387-3 Bus Extender Bus Splitter/Repeater Single Zone Expansion 8-zone Expansion 4-zone Class B Expansion 8-zone Class B Expansion 16-zone Class B Expansion 4-zone 2-wire smoke Expansion 8-zone 2-wire smoke Expansion 16-zone 2-wire smoke Expansion CDMA Cellular Communicator (Verizon) HSPA+ Cellular Communicator (AT&T, T-Mobile) Replacement Level 400 SIM Card 12’ SMA Coax Cable Extension 25’ SMA Coax Cable Extension Rubber Duck Antenna 3dB Fiberglass Antenna 2dB Attack Enclosure Antenna 3dB MEG Antenna INTRUSION DETECTORS Sentrol® Contacts and Sensors Optex PIRs Potter Contacts and Sensors Tane Contacts and Water Sensors Virtually any other Intrusion Detectors FOR RETAIL INSTALLATIONS Late to Open/Early to Close feature sends a message to the central station if the facility isn’t opened on time or closed before the scheduled time. The Traffic Count sends a daily tally of trips for the specified zone. With the Receiver 1 & 2 operation, Auxiliary 1 & 2 Zone messages can be sent to a specific receiver, enabling retail clients to alert a specific guard station of potential shoplifting in a certain area or other type of notifications. DOOR ACCESS 734 Wiegand Interface Module OP-08CB REX Motion Detector PB-2 Request-to-Exit Button Proximity Readers and Credentials DMP ProxPatch CENTRAL STATION RECEIVERS SCS-1R Security Control Receiver SCS-105 Single-Line DMP Serial 3 Receiver Compatible with Receivers that accept Standard CID, DMP Serial 3 or Network messaging. 1129 1131 1135 1135dB 1137 1139 1141 1142 1142BC COMPUTER SOFTWARE 1145-4-B 1145-2-B 1145-1-B 1148 1161 1162 1164 DMP WIRELESS 1165 1183-135F 1183-135R 1184 SCS-VR (Virtual Receiver) Software only solution that runs on a server for network IP and cellular communications. Remote Link Programming Software System Link End-User Management Software Link Server Application 1100D 1100DI 1100DH 1100R 1101 1102 1103 1106 1107 1114 1116 1117 1119 1121 1126R 1127C 1127W Receiver In-line Receiver High Power Receiver Repeater Universal Transmitter,Internal and External Contacts Universal Transmitter, External Contact Universal Transmitter, Internal and External Contact Universal Transmitter, Internal and External Contact Micro Window Transmitter Four-Zone Expander Relay Output LED Annunciator Door Sounder Pet Immune PIR Motion Detector 360 Ceiling Mount PIR Wall Mount Curtain PIR Wall Mount Wide Angle PIR ORDERING INFORMATION SYSTEM SPECIFICATIONS Primary Power Secondary Power Outputs Auxiliary Alarm Smoke Annunciator (4) Enclosures: Material Model 340 (Gray) Model 349 (Gray) Model 349A (Gray Attack) DMP WIRELESS CONT. Cold-rolled steel 12.5” W x 9.5” H x 2.75” D 12.25” W x 11.75” H x 3.125” D 13.25” W x 11.3” H x 3.6” D OTHER WIRELESS 738A 738I 738Z Ademco 32-point Expansion Module ITI 96-point Expansion Module Z-Wave Interface Module ACCESSORIES 300 307 307-S 335 370 399 300-9800-4 861 Four-wire Harness Clip-On Tamper Switch Screw-On Tamper Switch Intrusion Siren Lightning Suppressor Programming Harness Four-wire Replacement Harness Power Distribution Module MOBILE APPLICATIONS Virtual Keypad™ App MyAccess™ MyVirtualKeypad.com LISTINGS AND APPROVALS 16.5 VAC, 40 VA transformer (Model 321) 12 VDC Battery 500mA at 12 VDC 1.5 Amps at 12 VDC 100mA at 12 VDC 50mA each (switched ground) Glassbreak Detector Recessed Contact Siren, 100dB Siren, 110dB LED Emergency Light Bill Trap Wall Button Two-Button Hold-up Transmitter Two-Button Belt Clip Hold-up Transmitter Four-Button Key Fob Two-Button Key Fob One-Button Key Fob Personal Pendant Residential Smoke Detector Residential Smoke/Heat Detector Smoke Detector with Synchronized Sounder Commercial Smoke Detector Heat Detector Heat Detector Carbon Monoxide Detector California State Fire Marshal (CSFM) ETL: ANSI/SIA CP-01-2010 False Alarm Reduction ANSI/UL 1023 Household Burglar ANSI/UL 985 Household Fire Warning ANSI/UL 1635 Digital Burglar ANSI/UL 1610 Central Station Burglar FCC Part 15 ID: CCKPC0096 FCC Part 68 Registration ID CCKAL00BXT50 Industry Canada ID: 5251A-PC0096 Refer to the XT Series Installation Guide, Programming Guide and specific compliance listings for installation and programming requirements necessary to meet a particular approval. For additional information, access www.dmp.com and select Compliance. CUSTOMER SERVICE: 866.266.2826 14 XT SERIES SYSTEM DESIGN Cell J19 Cellular Antenna XT30/XT50 Panel J7 RJ Supervision J3 Phone Line J20 Wireless Antenna connection J24 Cellular header for 263C/263H connection NETWORK/INTERNET J11 J1 Ethernet Virtual Keypad App USER Network 1 2 3 4 Outputs J16 Reset Dialer Battery Negative Battery Positive Wire into DMP Model 320 wire-in or 321 plug-in Transformers Bell Zones 1 to 9 1K Ohm EOL on each zone Zone 10 3.3K Ohm EOL CENTRAL STATION AUTOMATION Keypad Bus Use 22 or 18 AWG 4-conductor unshielded wire up to 2,500 ft Additional Keypad Bus Devices Built-in Prox Reader 734 Interface Module 7063 Thinline Keypad External or Built-in Reader 15 7800 Graphic Touchscreen Keypad 9800 Wireless Graphic Touchscreen Keypad DMP KEYPAD BUS DEVICES 7000 Series Thinline Keypads 7000A Series Aqualite Keypads 7300 Series Icon Keypads 7800 Touchscreen Keypads 9800 Wireless Touchscreen Keypads 734 Wiegand Interface Module FAX: 800.743.5724 HARDWARE EXPANSION MODULES 708 Bus Extender 710 Bus Splitter/Repeater 711 Single Zone Expansion 712-8 8-zone Expansion 714 4-zone Class B Expansion 714-8 8-zone Class B Expansion 714-16 16-zone Class B Expansion 715 4-zone 2-wire smoke Expansion 715-8 8-zone 2-wire smoke Expansion 715-16 16-zone 2-wire smoke Expansion TWO WAY DMP WIRELESS DEVICES 1100D Receiver 1100DI In-line Receiver 1100DH High Power Receiver 1100R Repeater 1101 Universal Transmitter, Internal and External Contact 1102 Universal Transmitter, External Contact 1103 Universal Transmitter, Internal and External Contact 1106 Universal Transmitter, Internal and External Contact 1107 Micro Window Transmitter 1114 Four-Zone Expander 1116 Relay Output 1117 LED Annunciator 1118R Remote Indicator Light 1119 Door Sounder 1121 Pet Immune PIR Motion Detector 1126R 360 Ceiling Mount PIR 1127C Wall Mount Curtain PIR 1127W Wall Mount Wide Angle PIR 1129 Glassbreak Detector 1131 1135 1137 1135DB 1139 1141 1142 1142BC 1145-4-B 1145-2-B 1145-1-B 1148 1161 1162 1164 1165 1183-135F 1183-135R 1184 9000 9800 Recessed Contact Siren, 100 dB LED Emergency Light Siren, 110 dB Bill Trap Wall Button Two-Button Hold-up Transmitter Two-Button Belt Clip Hold-up Transmitter Four-Button Key Fob Two-Button Key Fob One-Button Key Fob Personal Pendant Residential Smoke Detector Residential Smoke/Heat Detector Smoke Detector with Synchronized Sounder Commercial Smoke Detector Heat Detector Heat Detector Carbon Monoxide Detector Wireless Keypad Wireless Touchscreen Keypad CUSTOMER SERVICE: 866.266.2826 16 INTRUSION PANELS XR150 FLEXIBLE COMMUNICATION The XR150 has transitioned from dialerfocused communications to a true network and cellular communications approach by providing stronger, multi-layered panel communications that ensure a constant link between the panel and Central Station. Installers have the ability to create, configure and manage up to eight communication paths. The unique DMP Serial 3 format supports 32-character user, zone and area names to decrease the central station response time and limit dependence on automation literal tables for message conversion. XR150 SPEC NETWORK OR CELLULAR COMMUNICATION Built-in 10/100 auto-sensing Ethernet connection enhances both standard and encrypted line security options. Both UDP and TCP are supported. The network option can be used as the primary or backup path to the digital dialer or cellular option. • On-Board 10/100 Network Communication • Plug-in cellular communicators allow for MyAccess™, Virtual Keypad™ App, and Central Station connection • Flash Updateable: No more firmware chips to replace • Adaptive Technology™ — Cost-effective supervised cellular backup • Up to 100 DMP 1100 Series Wireless or Wired LX Bus • Up to 99 schedules for areas, doors, outputs, holidays, Z-Wave Favorites, and profiles DMP XR150 Series™ Panels meet all your Burglary, Fire, and Access Control needs. The 263C/263H plug-in Digital Cellular Communicators can be used as the primary path, providing installation flexibility where no land lines are available. It can be used as a stand-alone communicator without the need for a backup. When used as the backup path, the 263C/263H provides the security of a communication link that continues to function, even when landlines are cut or compromised. This interface works on digital Cellular CDMA or HSPA+ data networks over a variety of carriers in the USA and Canada. ADAPTIVE TECHNOLOGY XR150 SERIES ACCESS/BURGLARY/FIRE 142-ZONE PANEL SYSTEM FEATURES • Select Area, All/Perimeter, or Home/Sleep/Away operation • Flexible system arming features, with Instant Arming option • 8 individual reporting areas, with common areas • Lock Down operation from keypad or remotely • Up to 8 supervised door access-points and/or keypads • Up to 130 two-wire smoke detector or fire-initiating zones • 32 character names available for user, zone, area, profiles and group names • 10,000 user codes with 99 profiles • Up to 4 profiles per user • Fully supervised 10/100 network and CDMA/HSPA+ cellular communication • Communications Diagnostics check network and cellular communication status from the keypad. • Eight communication paths between the panel and Central Station • Guest operation allows up to two separate protected systems 17 FAX: 800.743.5724 • Mobile platform support via text and the Virtual Keypad™ App • 12,000 event buffer • Built-in phone line monitor • Multi-lingual menus available by user • 1.5 Amps 12 VDC smoke and auxiliary output with OVC protection • EASYconnect™ connection for the Virtual Keypad™ App when used with a network connection ZONE AUDIT DAYS If a current primary communication path becomes unavailable, Adaptive Technology directs the panel to make a seamless transition from one communication path to another, ensuring that no check-in or supervision messages are missed. This allows a system to be fully supervised when the primary communication path is unavailable, while minimizing expensive cell traffic when all paths are good. The panel is constantly checking the failed path to enable the panel to revert back to the primary path COMMUNICATION FUNCTION when communication is restored. DIAGNOSTICS TECHNOLOGY FALSE ALARM FEATURES A valuable auditing tool to determine Providing end users with a way to reduce whether a zone or device has not been false alarms, both Cancel/Verify™ and tripped within a certain number of the False Alarm Question features prompt days, whether the system is armed or end users to validate whether an alarm disarmed.0 - 365 days can elapse without has occurred after entering their code. the zone being tripped. Each time the zone In a Home/Sleep/Away or All/Perimeter is tripped, the counter restarts. After the system, the user can either press CANCEL/ countdown expires, a fault message is sent VERIFY or YES/NO to confirm alarm status and the Zone Audit Days timer restarts and and send to the Central Station. begins the countdown again as per the GUEST OPERATION prorammed days. Using the Home/Sleep/Away with Guest EIGHT COMMUNICATIONS PATHS House operation, create up to two separate Create, configure, and manage up to eight systems (main and one guest). Keypads communication paths between the panel and in each system can selectively arm the Central Station. Each path has its own panel perimeter, interior, or bedrooms for only communication programming parameters, their protected areas. Main system users and can be identified as either primary or can add authorized users to all protected backup. This enables installers to configure a areas, but guests can add users only for reliable communication link, offering greater their protected system. confidence that the panel will always be connected to the Central Station. AREAS Program up to 8 areas with a variety MOBILE PLATFORMS of options, including independent arming. DMP mobile platforms provide you with the Each area has a unique name and may tools you need to build strong connections have its own account number. with your customers. Common areas automatically arm when • MyAccess™ enables end users to the last independent area is armed and monitor and manage their systems disarm when the first independent area remotely from any mobile phone using is disarmed. This is ideal for lobbies or simple SMS texting. areas where users need common access to specific areas only. • The Virtual Keypad™ App puts a keypad on the user’s Apple iPhone®, iPad™, or DMP WIRELESS Android compatible devices. DMP wireless communication MYVIRTUALKEYPAD.COM employs 900MHz frequencyhopping spread-spectrum to Users can access their security system via ensure clear and accurate internet connection on a tablet or computer. signal transmissions without interference Customers log into myvirtualkeypad.com in practically any environment.Receivers are with their login and system user code. alerted of transmitters that go missing with Two-Way communication. Each wireless Z-WAVE® SUPPORT transmitter communicates with the receiver Add up to 232 Z-Wave devices with the using supervision messages. 738Z module for mobile control of lights, locks, and thermostats. Up to 20 favorites The on-board LED on all 1100 Series allows users to program multiple devices Transmitters provides built-in survey to respond to a single command or panel capability to allow for single-person events like arming and disarming. Z-Wave installations, eliminating the requirement for devices can be controlled with both an external survey kit. MyAccess™ and the DMP App. The enhanced diagnostic menu enables technicians to check network and cellular communication status, and cell signal strength from the keypad. EASYconnect enables the control panel to establish an outbound connection to SecureCom over the network. This allows ACCESS CONTROL for an effortless installation of network BURGLARY INTEGRATION The XR150 is an integrated burglary, fire panels, without any customer router and access control system that can be programming, providing extremely quick configured for users to gain access and App connection times. disarm the area using a single card read! Exclusive DMP Wireless features include Sensitivity, Pulse Count, Walk Test, & Disarm Disable. Motion sensors can be configured from the panel, allowing for simple, fast, oneperson installation. Adjustable sensitivity via panel programming, battery-saving Disarm Disable, pulse count programming that allows multiple triggers before an alarm is initiated, and Walk Test Mode for sensor setup. Wireless Receivers and repeaters are authorized for wireless Commercial Burglary and Commercial Fire applications. CUSTOMER SERVICE: 866.266.2826 18 INTRUSION PANELS LOCK DOWN REAL-TIME STATUS ENHANCES VALUABLE VISUAL For emergency situations, a lock down 3RD-PARTY INTEGRATION ALARM INDICATOR command can be issued from the keypad Alarm systems are increasingly being In a normal state, both the keypad and logo menu or via remote command and locks integrated with environmental control and backlighting remain Blue on Aqualite all doors designated as public. home automation systems. With real-time keypads or Green on Thinline keypads. status information from zones, doors, and However, during an alarm state, the TEMPORARY CODES other outputs, XR150 Series panels are keypad and logo turn Red. The change in Temporary codes are user codes that can readily integrated with these third-party color allows persons on-site to instantly be entered with a finite date and specific control and automations systems. See recognize an alarm condition. time to expire. dmp.com/Integration_Partners. ZONE EXPANSION The XR150 provides up to 142 zones, programmable for burglary, fire, and access applications. • 10 On-Board Zones • 8 Keypads = 32 Zones • 1 built-in LX Bus (100 zones) ONE-MAN WALK TEST KEYPAD SHORTCUT KEYS Time-saving shortcut keys provide onebutton access to system control, making frequently used functions like system arming, fast and simple. The shortcut keys enable users to arm, monitor zones, test, or reset the system and perform a variety of other functions faster and easier. Shortcut keys included are: All, Reset, Home, Chime, Perim, and Sleep. Red Backlighting for Alarm Conditions A special code is also available for installers to test the system. The One-Man Walk Test ACCESS CONTROL 7800/9800 GRAPHIC KEYPAD feature allows a single technician to check The XR150 system can restrict access by Provides Touchscreen control for all the panel response to burglary, fire, panic, schedule, arming level, or other criteria. keypad functions. Slim profile in stylish and supervisory zones. The specific reason for access denial can be gloss black or white finish with a 5 inch, displayed on the keypad, stored in events, OUTPUTS full-color display. sent to the central station, DMP Advanced The XR150 provides up to 106 outputs that Your Logo Here Reporting, and Entré software. Anti-passback can be activated by zone or system events, feature also available. by schedule, through the User Menu or when a card is presented. Output Groups 8 INDEPENDENT ACCESS allow multiple outputs to activate with a CONTROL DOORS single event and/or can be assigned to a Any access control reader with a Wiegand particular user profile. output can be connected to the XR150 Series panel. Attach card reader inputs to MULTI-LINGUAL DISPLAY OPTION up to 8 different locations. XR150 Series systems may be programmed to display the User Menu and Status Display THINLINE™ AND 7800 Graphic Keypad text in multiple languages. FLEXIBILITY IN SCHEDULES Enhanced scheduling for areas, doors, outputs, and holiday schedules offer flexibility for your customers. 99 programmable schedules are available and can be assigned to an area, door, or output. The same schedule may be assigned to more than one area, door, or output, making them reusable. A LIST key facilitates browsing through the list of stored names on the keypad. • Up to 8 schedules per profile • Up to 8 schedules per door • Up to 8 schedules per area • Up to 8 schedules per output • Up to 40 holiday dates AQUALITE™ KEYPADS The stylish and sleek 7000 Series keypads 9000 SERIES WIRELESS KEYPAD provide three 2-button Panic keys, AC The 9060 and 9063 Wireless Keypads are supervised keypads that provide power and Armed LEDs, 32-character installation flexibility. These full-feature display, backlit logo and keyboard plus an keypads include four 2-button panic keys internal speaker. Aqualite Series keypads and an internal sounder. The backlit offer a brilliant Aqua colored LCD display keypad is easy to read, and both the keypad and backlighting. The 7063 keypad also and logo turn Red in alarm conditions, includes a built-in proximity reader for providing a visual alert. Both Keypads have codeless arming and disarming. a 32-character liquid crystal display, and can be programmed with a 16-character home or business name. The 9063 keypad also includes a built-in proximity reader for codeless arming and disarming. Aqualite/Thinline Keypad 9000 Wireless Keypad 19 FAX: 800.743.5724 KEYPADS 630F 7000 7000A 7800 9060 9063 9800 LCD Remote Fire Command Series Thinline Keypads Series Aqualite Keypads Graphic Touchscreen Keypads Wireless Keypad Wireless Keypad w/ Prox Reader Wireless Touchscreen Keypads EXPANSION MODULES 708 710 711 712-8 714 714-8 714-16 715 715-8 715-16 716 717 736P 738A 738I Bus Extender Bus Splitter/Repeater Single Zone Expansion 8-zone Expansion 4-zone Class-B Expansion 8-zone Class-B Expansion 16-zone Class-B Expansion 4-zone 2-wire smoke Expansion 8-zone 2-wire smoke Expansion 16-zone 2-wire smoke Expansion Output Expansion, 4 Form C relays, 4 open collector outputs Graphic Annunciator: 20 open collector outputs Radionics Interface Ademco Interface Module ITI Interface Module CELLULAR COMMUNICATORS 263C 263H CDMA Cellular Communicator HSPA+ Cellular Communicator AUXILIARY MODULES 860 865 866 867 869 893A Relay Output Module Style W/X Notification Circuit Module Style W Notification Circuit Module LX-Bus Notification Circuit Module Style D Initiating Circuit Module Dual Phone Line Module POWER SUPPLIES 505-12LX 505-12L 505-12A 5 Amps @ 12 VDC Amps @ 12 VDC Amps @ 12 VDC SMOKE/HEAT DETECTORS 2W-BLX 2WT-BLX Conventional Smoke Conventional Smoke/Heat INTRUSION DETECTORS Sentrol® Contacts and Sensors Optex PIRs Potter Contacts and Sensors Tane Contacts and Water Sensors Virtually any other Intrusion Detectors ACCESS CONTROL 734 Wiegand Interface Module 734N Network Wiegand Interface Module 734N-WIFI WiFi Wiegand Interface Module OP-08CB/W REX Motion Detector PB-2 Request-to-Exit Button Proximity Readers and Credentials DMP ProxPatch CENTRAL STATION RECEIVERS SCS-1R SCS-105 Security Control Receiver Single-Line DMP Serial 3 Receiver Compatible with Central Station Receivers that accept Standard CID, DD, or DMP Serial 3 messaging SCS-VR (Virtual Receiver) Software only solution that runs on a server for network IP and cellular communications DMP WIRELESS 1100X 1100XH 1100R 1101 1102 1103 1106 1107 1114 1116 1117 1118 1119 1121 1126R 1127C 1127W 1129 DMP WIRELESS CONTINUED 1131 1135 1137 1135DB 1139 1141 1142 1142BC 1145-4-B 1145-2-B 1145-1-B 1148 1161 1162 1164 1165 1165H 1165HS 1183-135F 1183-135R 1184 Recessed Contact Siren, 100 dB LED Emergency Light Siren, 110 dB Bill Trap Wall Button Two-Button Hold-up Transmitter Two-Button Belt Clip Hold-up Transmitter Four-Button Key Fob Two-Button Key Fob One-Button Key Fob Personal Pendant Residential Smoke Detector Residential Smoke/Heat Detector Smoke Detector with Synchronized Sounder Commercial Smoke Detector Commercial Smoke/Heat Detector Commercial Smoke/Heat Detector with Sounder Heat Detector (Fixed) Heat Detector (Rate of Rise) Carbon Monoxide Detector ACCESSORIES Receiver High Power Receiver Repeater Universal Transmitter, Internal and External Contacts Universal Transmitter, External Contact Universal Transmitter, Internal and External Contacts Universal Transmitter, Internal and External Contact Micro Window Transmitter Four-Zone Expander Relay Output LED Annunciator Remote Indicator Light Door Sounder Pet Immune PIR Motion Detector 360 Ceiling Mount PIR Wall Mount Curtain PIR Wall Mount Wide Angle PIR Glassbreak Detector 270 277 300 303 305 306 307-S 3012 335 370 374 431 738Z 861 300-9800-4 Network Transient Suppressor Commercial Fire Buzzer Module Four-wire Harness Silence/Reset Push-Button Plug-in Output Relay Tamper Harness Screw-On Tamper Switch Clip-On Tamper Switch Intrusion Siren Lightning Suppressor Surge Voltage Suppressor Output Harness Z-Wave Interface Module Power Distribution Module Four-Wire Replacement Harness COMPUTER SOFTWARE Remote Link Programming Software System Link End-User Management Software Link Server Application Entré Access Control Software MOBILE APPLICATIONS DMP App MyAccess™ MyVirtualKeypad.com SYSTEM SPECIFICATIONS LISTINGS AND APPROVALS Primary Power (included) Secondary Power Models Output Rating Bell Smoke and Auxiliary Current Draw Enclosures: Material Model 350 (Gray or Red) Model 350A (Gray) Model 352X (Gray) Model 341 (Gray) New York FDNY FCC Part 68 FCC Part 15 Underwriters Laboratories (UL) Listed: UL Standard Line Security Underwriters Laboratories Canada (ULC) Listed California State Fire Marshal (CSFM) 16.5 VAC 50 VA transformer 12 VDC Battery 364, 365, 366, 368 or 369 1.5 Amps at 12 VDC 1.5 Amps at 12 VDC 180mA Cold-rolled steel 17.5” W x 13.5” H x 3.5” D 17.5” W x 13.5” H x 3.75” D 14.5” W x 32” H x 34” D 12.75” W x 6.55” H x 3.15” D For additional approval information, access www.dmp.com and select Compliance. CUSTOMER SERVICE: 866.266.2826 20 INTRUSION PANELS XR550 FLEXIBLE COMMUNICATION The XR550 has transitioned from dialerfocused communications to a true network and cellular communications approach by providing stronger, multilayered panel communications that ensure a constant link between the panel and Central Station. Installers have the ability to create, configure and manage up to eight communication paths. XR550 in 352X Enclosure (Sold separately) The unique DMP Serial 3 format supports 32-character user, zone and area names to decrease the central station response time and limit dependence on automation literal tables for message conversion. NETWORK OR CELLULAR COMMUNICATION XR550 SPEC • On-Board 10/100 Network Communication • Plug-in cellular communicators allow for MyAccess™, DMP App, and Central Station connection • Flash Updateable: No more firmware chips to replace • Adaptive Technology™ — Cost-effective supervised cellular backup • Up to 500 DMP 1100 Series Wireless or Wired LX Bus • Up to 99 schedules for areas, doors, outputs, Z-Wave Favorites, and profiles DMP XR550 Series™ Panels meet all your Burglary, Fire, and Access Control needs. XR550 in 350 Enclosure XR550 SERIES ACCESS/BURGLARY/FIRE 574-ZONE PANEL SYSTEM FEATURES • Select Area, All/Perimeter, or Home/Sleep/Away operation • 506 Outputs • 32 individual reporting areas, with common areas • 12,000 event buffer • Up to 16 supervised door access-points and/or keypads • Built-in phone line monitor • 32 character names available for user, zone, area, profiles and group names • Multi-lingual menus available by user • Up to 4 profiles per user • Fully supervised 10/100 network and cellular communication • Communications Diagnostics check network and cellular communication status from the keypad. • Eight communication paths between the panel and Central Station • Guest operation allows up to three separate protected systems • Flexible system arming features, with Instant Arming option • Card plus pin and temporary codes • Lock Down operation from keypad or remotely • 1.5 Amps 12 VDC smoke and auxiliary output with OVC protection • User inactivity audit • EASYconnect™ connection for the DMP App when used with a network connection XR550DN/XR550DE SYSTEM FEATURES • Bank, Safe and Vault Operation • Two Man Rule, Panic Button Test and Early Morning Ambush XR550DE SYSTEM FEATURES • 128 & 256 Bit AES (Advanced Encryption Standard) Encryption • Up to 562 two-wire smoke detector or fire-initiating zones • NIST Certified • 10,000 user codes with 99 profiles • Meets ICPG 705 21 FAX: 800.743.5724 Built-in 10/100 auto-sensing Ethernet connection enhances both standard and encrypted line security options. Both UDP and TCP are supported. The network option can be used as the primary or backup path to the digital dialer or cellular option. The 263C/263H plug-in Digital Cellular Communicator can be used as the primary path, providing installation flexibility where no land lines are available. It can be used as a stand-alone communicator without the need for a backup. When used as the backup path, the 263C/263H provides the security of a communication link that continues to function, even when landlines are cut or compromised. This interface works on digital Cellular CDMA or HSPA+ data networks over a variety of carriers in the USA and Canada. ADAPTIVE TECHNOLOGY If a current primary communication path becomes unavailable, Adaptive Technology directs the panel to make a seamless transition from one communication path to another, ensuring that no check-in or supervision messages are missed. This allows a system to be fully supervised when the primary communication path is unavailable, while minimizing expensive cell traffic when all paths are good. The panel is constantly checking the failed path to enable the panel to revert back to the primary path when communication is restored. TECHNOLOGY EASYconnect enables the control panel to establish an outbound connection to SecureCom over the network. This allows for an effortless installation of network panels, without any customer router programming, providing extremely quick App connection times. ZONE AUDIT DAYS FALSE ALARM FEATURES A valuable auditing tool to determine Providing end users with a way to reduce whether a zone or device has not been false alarms, both Cancel/Verify™ and tripped within a certain number of days, the False Alarm Question features prompt whether the system is armed or disarmed. end users to validate whether an alarm 0 - 365 days can elapse without the zone has occurred after entering their code. being tripped. Each time the zone is In a Home/Sleep/Away or All/Perimeter tripped, the counter restarts. After the system, the user can either press CANCEL/ countdown expires, a fault message is sent VERIFY or YES/NO to confirm alarm status and the Zone Audit Days timer restarts and and send to the Central Station. begins the countdown again as per the AREAS programmed days. Program up to 32 areas with a variety USER INACTIVITY of options, including independent arming. The User Inactivity audit provides notification Each area has a unique name and may of user codes or credentials not used over a have its own account number. programmable period of time. For example, Common areas automatically arm when employees or service provides that haven’t the last independent area is armed and used their PIN code or access credentials disarm when the first independent area during a defined period of time. This is disarmed. This is ideal for lobbies or notification promotes the purging of user areas where users need common access and access rights as a result of employee to specific areas only. termination or service provider changes. This option is found in System Options DMP WIRELESS Programming. DMP wireless communication EIGHT COMMUNICATIONS PATHS employs 900MHz frequencyCreate, configure, and manage up to eight hopping spread-spectrum communication paths between the panel and to ensure clear and accurate Central Station. Each path has its own panel signal transmissions without interference communication programming parameters, in practically any environment.Receivers and can be identified as either primary or are alerted of transmitters that go missing backup. This enables installers to configure a with Two-Way communication. Each reliable communication link, offering greater wireless transmitter communicates with confidence that the panel will always be the receiver using supervision messages. connected to the Central Station. The on-board LED on all 1100 Series MOBILE PLATFORMS Transmitters provides built-in survey DMP mobile platforms provide you with the capability to allow for single-person tools you need to build strong connections installations, eliminating the requirement with your customers. for an external survey kit. • MyAccessTM enables end users to Exclusive DMP Wireless features include monitor and manage their systems Sensitivity, Pulse Count, Walk Test, remotely from any mobile phone using & Disarm Disable. Motion sensors can simple SMS texting. be configured from the panel, allowing • The Virtual KeypadTM App puts a for simple, fast, one-person installation. keypad on the user’s Apple iPhone®, Adjustable sensitivity via panel iPadTM, or Android compatible devices. programming, battery-saving Disarm Disable, pulse count programming that Dealers can offer these much-appreciated allows multiple triggers before an alarm services to their customers and realize the is initiated, and Walk Test Mode for sensor benefits of additional recurring revenue setup. Wireless Receivers and repeaters COMMUNICATION are authorized for wireless Commercial Burglary and Commercial Fire applications. FUNCTION DIAGNOSTICS The enhanced diagnostic menu enables WIRELESS ONE BUTTON KEYFOB technicians to check network and cellular WITH PROX PATCH communication status, and cell signal The 1145-1-BP is a wearable and portable strength from the keypad. panic button fob, programmable to function ACCESS CONTROL in multiple locations, with alerts for lost fobs, late to test, and lower battery power. BURGLARY INTEGRATION The XR550 is an integrated burglary, fire and access control system that can be configured for users to gain access and disarm the area using a single card read! CUSTOMER SERVICE: 866.266.2826 22 INTRUSION PANELS LOCK DOWN REAL-TIME STATUS ENHANCES VALUABLE VISUAL For emergency situations, a lock down 3RD-PARTY INTEGRATION ALARM INDICATOR Alarm systems are increasingly being command can be issued from the keypad In a normal state, both the keypad and integrated with environmental control and menu or via remote command and locks logo backlighting remain Blue on Aqualite home automation systems. With real-time all doors designated as public. keypads or Green on Thinline keypads. status information from zones, doors, and However, during an alarm state, the other outputs, XR550 Series panels are TEMPORARY CODES keypad and logo turn Red. The change in readily integrated with these third-party Temporary codes are user codes that can color allows persons on-site to instantly control and automations systems. See be entered with a finite date and specific recognize an alarm condition. dmp.com/Integration_Partners. time to expire. KEYPAD SHORTCUT KEYS ZONE EXPANSION The XR550 provides up to 574 zones, programmable for burglary, fire, and access applications. • 10 On-Board Zones • 16 Keypads = 64 Zones • 5 built-in LX Bus (100 zones per LX) ONE-MAN WALK TEST Time-saving shortcut keys provide onebutton access to system control, making frequently used functions like system arming, fast and simple. The shortcut keys enable users to arm, monitor zones, test, or reset the system and perform a variety of other functions faster and easier. Shortcut keys included are: All, Reset, Home, Chime, Perim, and Sleep. Red Backlighting for Alarm Conditions A special code is also available for installers ACCESS CONTROL to test the system. The One-Man Walk Test The XR550 system can restrict access by schedule, arming level, or other criteria. 7800/9800 GRAPHIC KEYPAD feature allows a single technician to check The specific reason for access denial can the panel response to burglary, fire, panic, Provides Touchscreen control for all keypad be displayed on the keypad, stored in and supervisory zones. functions. Slim profile in stylish gloss black events, sent to the central station, and or white finish with a 5 inch, full-color display. DMP Advanced Reporting. Anti-passback OUTPUTS feature also available. The XR550 provides up to 506 outputs that Your Logo Here can be activated by zone or system events, Z-WAVE® SUPPORT by schedule, through the User Menu or Add up to 232 Z-Wave devices with the when a card is presented. Output Groups 738Z module for mobile control of lights, allow multiple outputs to activate with a locks, and thermostats. Up to 20 favorites single event and/or can be assigned to a allows users to program multiple devices to respond to a single command or panel particular user profile. events like arming and disarming. Z-Wave MULTI-LINGUAL DISPLAY OPTION devices can be controlled with the 7800 Touchscreen Keypad or MyAccess™ and XR550 Series systems may be programmed the DMP App. to display the User Menu and Status Display 7800 Graphic Keypad text in multiple languages. 16 INDEPENDENT ACCESS FLEXIBILITY IN SCHEDULES CONTROL DOORS Any access control reader with a Wiegand Enhanced scheduling for areas, doors, output can be connected to the XR550 outputs, and holiday schedules offer Series panel. Attach card reader inputs to flexibility for your customers. 99 up to 16 different locations. programmable schedules are available and can be assigned to an area, door, THINLINE™ AND or output. The same schedule may be AQUALITE™ KEYPADS assigned to more than one area, door, The stylish and sleek 7000 Series keypads provide three 2-button Panic keys, AC or output, making them reusable. A LIST power and Armed LEDs, 32-character key facilitates browsing through the list of display, backlit logo and keyboard plus an stored names on the keypad. internal sounder. Aqualite Series keypads • Up to 8 schedules per profile offer a brilliant Aqua colored LCD display • Up to 8 schedules per door and backlighting. The 7063 keypad also includes a built-in proximity reader for • Up to 8 schedules per area codeless arming and disarming. • Up to 8 schedules per output • Up to 40 holiday dates 9000 SERIES WIRELESS KEYPAD 9000 series wireless keypad The 9060 and 9063 Wireless Keypads are supervised keypads that provide installation flexibility. These full-feature keypads include four 2-button panic keys and an internal sounder. The backlit keypad is easy to read, and both the keypad and logo turn Red in alarm conditions, providing a visual alert. Both Keypads have a 32-character liquid crystal display, and can be programmed with a 16-character home or business name. The 9063 keypad also includes a built-in proximity reader for codeless arming and disarming. 9000 Wireless Keypad ENCRYPTION The XR550DE provides encrypted data transmission and is ideal for secure environments where encrypted data is required. Using AES (Advanced Encryption Standard) Encryption ensures secure data transmission by using a unique alphanumeric passphrase. 23 9000 Wireless Keypad Aqualite/Thinline Keypad FAX: 800.743.5724 KEYPADS INTRUSION DETECTORS 630F 7000 7000A 7800 9060 9063 9800 DMP WIRELESS CONTINUED LCD Remote Fire Command Sentrol® Contacts and Sensors 1131 Recessed Contact Series Thinline Keypads Optex PIRs 1135 Siren, 100 dB Series Aqualite Keypads Potter Contacts and Sensors 1135DB Siren, 110 dB Graphic Touchscreen Keypads Tane Contacts and Water Sensors 1137 LED Emergency Light Wireless Keypad Virtually any other Intrusion Detectors 1139 Bill Trap Wireless Keypad w/ Prox Reader 1141 Wall Button Wireless Touchscreen Keypads ACCESS CONTROL 1142 Two-Button Hold-up Transmitter 734 Wiegand Interface Module 1142BC Two-Button Belt Clip 734N Network Wiegand EXPANSION MODULES Interface Module Hold-upTransmitter 708 Bus Extender 734N-WIFI WiFi Wiegand Interface Module 710 Bus Splitter/Repeater 1145-4-B Four-Button Key Fob OP-08CB REX Motion Detector 711 Single Zone Expansion 1145-2-B Two-Button Key Fob PB-2 Request-to-Exit Button 712-8 8-zone Expansion 1145-1-B One-Button Key Fob Proximity Readers and Credentials 714 4-zone Class B Expansion 1148 Personal Pendant DMP ProxPatch 714-8 8-zone Class B Expansion 1161 Residential Smoke Detector 714-16 16-zone Class B Expansion 1162 Residential Smoke/Heat Detector 715 4-zone 2-wire smoke Expansion CENTRAL STATION RECEIVERS 1165 Commercial Smoke Detector SCS-1R Security Control Receiver 715-8 8-zone 2-wire smoke Expansion SCS-105 Single-Line DMP Serial 1165H Commercial Smoke/Heat Detector 715-16 16-zone 2-wire smoke Expansion 3 Receiver Compatible with 1165HS Commercial Smoke/Heat 716 Output Expansion, 4 Form C Receivers that accept Detector with Sounder relays, 4 open collector outputs Standard CID, DD, or DMP 717 Graphic Annunciator: 20 open 1183-135F Heat Detector (Fixed) Serial 3 messaging collector outputs 1183-135R Heat Detector (Rate of Rise) SCS-VR (Virtual Receiver) 736P Radionics Interface Software only solution that 1184 Carbon Monoxide Detector runs on a server for network CELLULAR COMMUNICATORS IP and cellular communications ACCESSORIES 263C CDMA Cellular Communicator 270 Network Transient Suppressor 263H 4G HSPA+ Cellular Communicator DMP WIRELESS 277 Commercial Fire Buzzer Module 1100X Receiver 300 Four-wire Harness AUXILIARY MODULES 1100XH High Power Receiver 860 Relay Output Module 303 Silence/Reset Push-Button 1100R Repeater 865 Style W/X Notification 305 Plug-in Output Relay 1101 Universal Transmitter, Circuit Module Internal and External Contacts 306 Tamper Harness 866 Style W Notification 1102 Universal Transmitter, 307-S Screw-On Tamper Switch Circuit Module External Contact 3012 Clip-On Tamper Switch 867 LX-Bus Notification 1103 Universal Transmitter, Internal Circuit Module 335 Intrusion Siren and External Contact 869 Style D Initiating 370 Lightning Suppressor 1106 Universal Transmitter, Internal Circuit Module and External Contact 374 Surge Voltage Suppressor 893A Dual Phone Line Module 1107 Micro Window Transmitter 431 Output Harness 1114 Four-Zone Expander 738Z Z-Wave Interface Module POWER SUPPLIES 1116 Relay Output 861 Power Distribution Module 505-12/LX 5 Amps @ 12 VDC 1117 LED Annunciator 300-9800-4 Four-Wire Replacement Harness 505-12L 5 Amps @ 12 VDC 1118 Remote Indicator Light 505-12A 5 Amps @ 12 VDC 1119 Door Sounder COMPUTER SOFTWARE 1121 Pet Immune PIR Motion Detector SMOKE/HEAT DETECTORS Remote Link Programming Software 1126R 360 Ceiling Mount PIR 2W-BLX Conventional Smoke System Link End-User Management Software 2WT-BLX Conventional Smoke/Heat 1127C Wall Mount Curtain PIR Link Server Application 1127W Wall Mount Wide Angle PIR Entré Access Control Software 1129 Glassbreak Detector MOBILE APPLICATIONS DMP App MyAccess™ MyVirtualKeypad.com SYSTEM SPECIFICATIONS LISTINGS AND APPROVALS Primary Power (included) Secondary Power Models Output Rating Bell Smoke and Auxiliary Current Draw Enclosures: Material Model 350 (Gray or Red) Model 350A (Gray) Model 352X (Gray) Model 341 (Gray) New York FDNY FCC Part 68 FCC Part 15 Underwriters Laboratories (UL) Listed NIST Validated Certificate #2350 & #2595 Underwriters Laboratories Canada (ULC) Listed California State Fire Marshal (CSFM) 16.5 VAC 50 VA transformer 12 VDC Battery 364, 365, 366, 368 or 369 1.5 Amps at 12 VDC 1.5 Amps at 12 VDC 180mA Cold-rolled steel 17.5” W x 13.5” H x 3.5” D 17.5” W x 13.5” H x 3.75” D 14.5” W x 32” H x 34” D 12.75” W x 6.55” H x 3.15” D For additional approval information, access www.dmp.com and select Compliance. CUSTOMER SERVICE: 866.266.2826 24 XR550 SYSTEM DESIGN Cell USER NETWORK/INTERNET ª Virtual Keypad App Network Dialer Wire into DMP Model 322/323/324/324P wire-in or 327 plug-in Transformers CENTRAL STATION AUTOMATION Additional Keypad Bus Devices Use 22 or 18 AWG 4-conductor unshielded wire up to 2,500 ft Built-in Prox Reader DMP WIRELESS 1100X 1100XH 1100R 1101 1102 7063 Thinline Keypad 7800 Graphic Touchscreen Keypad 9800 Wireless Graphic Touchscreen Keypad 734 Interface Module DMP BUS DEVICES External or Built-in Reader 630F LCD Remote Fire Command 7000 Series Thinline Keypads 7000A Series Aqualite Keypads 7800 Touchscreen Keypads 734 Interface Module 734N Network Wiegand Interface Module 734N-WIFI WiFi Wiegand Interface Module EXPANSION MODULES 708 710 711 712-8 714 714-8 714-16 715 715-8 715-16 716 717 736P 25 FAX: 800.743.5724 Bus Extender Bus Splitter/Repeater Single Zone Expansion 8-zone Expansion 4-zone Class B Expansion 8-zone Class B Expansion 16-zone Class B Expansion 4-zone 2-wire smoke Expansion 8-zone 2-wire smoke Expansion 16-zone 2-wire smoke Expansion Output Expansion, 4 Form C relays, 4 open collector outputs Graphic Annunciator: 20 open collector outputs Radionics Interface 1103 1106 1107 1114 1116 1117 1118 1119 1121 1126R 1127C 1127W 1129 1131 1135 Receiver High Power Receiver Repeater Universal Transmitter, Internal and External Contacts Universal Transmitter, External Contact Universal Transmitter, Internal and External Contact Universal Transmitter, Internal and External Contact Micro Window Transmitter Four-Zone Expander Relay Output LED Annunciator Remote Indicator Light Door Sounder Pet Immune PIR Motion Detector 360 Ceiling Mount PIR Wall Mount Curtain PIR Wall Mount Wide Angle PIR Glassbreak Detector Recessed Contact Siren, 100 dB 1135DB 1137 1139 1141 1142 1142BC 1145-4-B 1145-2-B 1145-1-B 1148 1161 1162 1165 1165H 1165HS 1183-135F 1183-135R 1184 9000 9800 Siren, 110 dB LED Emergency Light Bill Trap Wall Button Two-Button Hold-up Transmitter Two-Button Belt Clip Hold-upTransmitter Four-Button Key Fob Two-Button Key Fob One-Button Key Fob Personal Pendant Residential Smoke Detector Residential Smoke/Heat Detector Commercial Smoke Detector Commercial Smoke/Heat Detector Commercial Smoke/Heat Detector with Sounder Heat Detector (Fixed) Heat Detector (Rate of Rise) Carbon Monoxide Detector Wireless Keypad Wireless Touchscreen Keypad CUSTOMER SERVICE: 866.266.2826 26 FIRE COMMUNICATIONS DIRECT REPORTING 263C/263H UL LISTED CDMA & HSPA+ CELLULAR COMMUNICATION FOR FIRE ALARM CONTROL PANELS 263C/263H SPEC The 263C/263H, when installed with a DMP XR150/XR150FC or XR550/XR550FC Panel, is UL approved as a primary (standalone) fire communicator with no backup, and is approved as a fire slave communicator, compatible with any FACP. The 263C/263H provides a dependable communications link between your alarm system panel and Central Station. • Compared to a dialup communication link, cellular can save significantly in annual telecommunication costs • UL Listed as the Primary Communicator and Fire Slave Input for the XR150/XR550 in Fire Applications under ANSI/UL 864 Commercial Fire (Meets NFPA 72) • Works on digital cellular data networks over a variety of carriers DIGITAL CELLULAR FIRE COMMUNICATORS FEATURES • 263C/263H enhances system security that conforms with NFPA and UL requirements • Direct reporting to the DMP Central Station receiver, with no relaying of alarm signals • Fire Slave Input option of the XR150/XR550 with 263C/263H approved for any FACP • Modular solution means easily updated for newer technologies • Eight-path redundancy with multiple message delivery available • DMP Adaptive Technology™ switches communication paths while maintaining supervision if the current path becomes unavailable 27 FAX: 800.743.5724 • 263C/263H uses power from panel with low current draw for long standby battery life • Can be equipped with local or remote antenna, offering more flexibility when installing • Ability to check signal strength indication at the keypad • Messaging features transmit alarms/alerts to users via SMS text messages, and allow users to remotely control their panel via text commands FULLY SUPERVISED ADAPTIVE TECHNOLOGY™ The digital cellular communicators You’re kept fully informed of system If the primary communication path is transmit IP data packets directly from the status. The unit sends full reporting compromised or becomes unavailable, panel’s processor over the wireless data messages including Zones, Areas, Adaptive Technology almost instantly network. All of the messages that are and Users, with all names and details switches to a designated backup path. capable of being sent by the control panel included. Full supervision ensures that the Where multiple backups are available, are received directly by the DMP Central cellular communication path is intact and communications can be programmed to Station receiver. There are no intermediary functional. switch to another path as necessary. servers or network operation centers, and The check in frequency and programming no retransmission or reinterpretation of EIGHT-PATH REDUNDANCY for a backup path adapt to the check in Feel more secure with up to eight paths of the information. Direct reporting means programming of the primary path. When communication redundancy. Select from faster response, with no concerns about the primary path becomes available, TCP, UDP, CDMA, HSPA+, Single Line signals not being properly relayed or normal communications are restored. Dialer, Dual Line Dialer with multiple IP intermediate communication links failing. Adaptive Technology provides additional numbers, and multiple telephone numbers. confidence in the integrity of your system, ADD-ON TO XR150/XR550 PANEL You identify and configure your redundant while protecting you from unexpected communication links via Remote Link. The 263C/263H works as an easy-to-install cellular service charges. XR150/XR550 expansion card, with plugA DACT (digital alarm communicator REDUCED EQUIPMENT NEEDS and-play ease of installation. No extra transmitter) system may be configured as: programming is required. It provides full With other cellular backup equipment, you data delivery of DMP Zones, Areas, and need to purchase additional enclosures, • Path 1 Type DD Primary and Path 2 Users, with all names and details included. power supplies, batteries, cabling, and Type DD Backup The remarkably compact 263C/263H conduit connections. The 263C/263H won’t take up a lot of space in your reduces the number of pieces of equipment • Path 1 Type DD Primary and Path 2 communications closet. The unit directly you have to purchase. It comes ready to Type CELL Backup installs in the panel expansion card slot, mount, reducing your initial costs and • Path 1 Type DD Primary and Path 2 which is mounted inside a sturdy UL-listed simplifying both installation and ongoing Type NET Backup metal cabinet. Tamper protection is also operation. available for added security. REDUCED COMMUNICATION COSTS A NET or CELL system may be UL LISTED configured as: Adding the cellular communicator to the DMP XR150/XR550 fire alarm control panel Install the DMP 263C/263H Digital Cellular • Path 1 Type NET Primary with no Backup can lower costs significantly compared Communicator in an XR150/XR550 Series • Path 1 Type CELL Primary with no Backup to dial-up connections. Fire systems panel to create a UL listed, primary typically require two dial-up lines that can communication path for commercial fire • Path 1 Type NET Primary and Path 2 be eliminated and replaced with a single installations. The Fire Slave Input option of Type DD Backup cellular connection. the XR150/XR550 has also been approved • Path 1 Type NET Primary and Path 2 under ANSI/UL 864 (NFPA 72 2007 & SLAVE COMMUNICATORS 2010), allowing it to be used as a Slave Type CELL Backup XR150/XR550 panels operate as slave Communicator for any FACP. • Path 1 Type CELL Primary and Path 2 communicators via cellular communication Type NET Backup in fire installations compatible with an FACP. In addition to standard hardwire slave communications that connect via inputs to the DMP panel, 1103 Wireless Transmitters can be installed to communicate FACP status. ANTENNA PLACEMENT The unit includes both local and remote SMA (S-band multiple access) antenna connections, giving you added freedom and flexibility during installation. 263H CUSTOMER SERVICE: 866.266.2826 28 FIRE COMMUNICATIONS LOW CURRENT DRAIN ENHANCED FIRE PROTECTION With its extremely low current drain and long standby battery life, the 263C/263H will continue to provide a communications link for an extended period of time, even during a power failure. It draws half the current of other comparable units. SIMPLE TO INSTALL AND PROGRAM Connect the 263C or 263H to your panel, attach the antenna and power, and installation is complete. Programming the 263C/263H is fast and simple, accomplished within the panel itself. After programming the 263C/263H cellular communications path via Remote Link, you will be presented with the Activate SIM/MEID window to activate your cellular plan. Once activated, the wireless backup connection is immediately online protecting your communications link. No separate programming utility is required. SECURECOM CELLULAR SERVICES Compared to dial-up connections, a digital cellular communication link provides greater reliability, protection from sabotage, and is less prone to being knocked out by weather. Unlike mobile cellular connections, the 263C/263H creates a fixed network connection that minimizes hand-offs and the chance for dropped connections. When trouble conditions occur, they can be more quickly diagnosed and often corrected remotely. The NFPA 72 code requires a test of the entire communications path every five minutes. The DMP Model XR150/XR550 Panel used with DMP 263C/263H Digital Cellular Communicator meets this requirement when check-in and fail time settings are programmed for five minutes. The net result is a higher level of system reliability in comparison with traditional systems that rely on redundant phone lines and the substantially less frequent 24-hour supervision reports associated with that approach. MYACCESS™ SMS Your customers can send many of the most common system commands to their residential or commercial systems via text messages. They can also choose to have alerts sent to them each time there’s an arm/disarm, an alarm, or other selected events. Alerts can be transmitted by the panel as text messages to up to three phones. Users can also use MyAccess to interact with any Z-Wave devices programmed through their DMP panel, enabling them to control lights, thermostats, and more via text commands. Use any model of cell phone for The 263H comes standard with a SIM UPDATEABLE In addition to being able to change cellular Messaging Features (Subscriber Identity Module) card ready to carriers, you will also be ready to take use SecureCom Wireless Cellular Service advantage of technical improvements as from DMP. The 263C does not include they occur. The unit’s modular architecture a SIM Card and is activated with the enables seamless upgrades as improved MEID number. With the 263C/263H and technology becomes available. SecureCom, you have a one-stop resource THE VIRTUAL KEYPAD APP for both hardware and cellular service. MOBILE PLATFORMS Dealers can invite their customers to begin DMP mobile platforms provide you using their APP to give them control of with the tools you need to build strong their security system. The Virtual Keypad connections with your customers. allows them to arm or disarm, and to check the status of their cellular connected DMP security system from anywhere • MyAccess™ enables end users to they have cell service. They can also monitor and manage their systems access any Z-Wave home control devices remotely from any mobile phone using programmed through their DMP panel and simple SMS texting. DMP cameras. • The Virtual Keypad™ App puts a keypad on the user’s Apple iPhone®, iPad™, or Android compatible devices. Dealers can offer these much-appreciated services to their customers and realize the benefits of additional recurring revenue. DMP WIRELESS DEVICES FOR ANSI/UL 864 COMMERCIAL FIRE Complete your fire system with other DMP wireless devices that are ANSI/UL 864 Listed for Fire Protective Signaling Systems. TWO-WAY COMMUNICATION Superior to traditional wireless devices that just broadcast until the zone is restored, DMP 1100 Series require an acknowledgement from the 1100 Series Receiver, indicating successful communication. This smart technology ensures that each and every communication is received and efficiently processed at the panel. With the 900MHz frequency-hopping spread-spectrum technology, clear and accurate signal transmissions without interference in practically any environment is to be expected. 1103 UNIVERSAL TRANSMITTER 1165/1165H/1165HS COMMERCIAL SMOKE DETECTORS 1100 SERIES RECEIVERS The Model 1165 Smoke Detector, 1165H Smoke/Heat Detector, and 1165HS Smoke/ Heat Detector with Sounder include a tamper switch that sends a trouble signal if the detector is removed from the mounting base. The 1100 Series Receivers: 1100X and 1100XH allow you to add up to 500 transmitters and is required for wireless capability in both regular and harsh environments. ACCESSORIES SPECIFICATIONS Primary Power Current Draw (263C) Standby Alarm Current Draw (263H) Standby Alarm 12 VDC from panel 13mA 13mA 24mA 28mA COMPATIBILITY DMP XR150 | XR550 Series Panels (A 381 cable is required for the XR150 | XR550 Series) ORDERING INFORMATION 263C 263C/381-2 263H 263H/381-2 1164 RESIDENTIAL/COMMERCIAL Model 1103 Universal Transmitter is SMOKE DETECTOR typically used in commercial fire or The Model 1164 smoke detector includes burglary door/ window applications. It synchronized sounders so when more offers the same look and features as than one 1164 is installed on a system, the the 1101 transmitter, with the addition alarm cadence will synchronize. Any fire of a 470k end-of-line resistor and wall zone tripped on the panel will cause the tamper switch. sounders to initiate. The 1164 also includes a tamper switch that sends a trouble signal when the detector is removed from the mounting base. Up to 572 units can be installed on one system. CDMA Cellular Communicator (Verizon) CDMA Cellular Communicator w/ 381-2 Cable (Verizon) HSPA+ Cellular Communicator (AT&T, T-Mobile, (263HCAN - Rogers)) HSPA+ Cellular Communicator w/ 381-2 Cable (AT&T, T-Mobile, (263HCAN - Rogers)) 318 381-2 381-12 381-25 383 386 387-1 387-2 387-3 387-25 387-50 Battery Harness 18" Coax Extension 12' Coax Extension 25' Coax Extension Rubber Duck Antenna Wall Mount Antenna Bracket 3dB Fiberglass Antenna w/bracket 2dB Attack Enclosure Antenna 3dB MEG Antenna SMA TO N CABLE, 25FT, LMR195 SMA TO N CABLE, 50FT, LMR195 LISTINGS AND APPROVALS New York FDNY California State Fire Marshal (CSFM) Underwriters Laboratories (UL) Listed Underwriters Laboratories Canada (ULC) Listed For additional approval information, access www.dmp.com and select Compliance. 29 FAX: 800.743.5724 CUSTOMER SERVICE: 866.266.2826 30 FIRE PANELS The XR150DFC and XR550DFC provide basic fire monitoring for any single site application. The XR150DNFC and XR550DNFC panels provide all the same basic fire monitoring as the XR150DFC and XR550DFC enhanced by the on-board Ethernet connection that allows the use of Network Monitoring™. Both panels come fully assembled from the factory with the following components: XR150FC/XR550FC CONTROL PANEL The XR150FC and XR550FC Series addressable fire panels provides complete system control for local NAC operation and DACT, NET, or Cell communication to the central station. The microprocessor based panel also provides input for Class A zone expansion, conventional and addressable smoke detectors, pull stations, and heat detectors. ENCLOSURE The enclosure is comprised of cold rolled steel in Red to distinguish it for fire operation. For added security, the enclosure comes with a lock and key. KEYPAD ANNUNCIATOR FIRE PANEL SPEC The Fire Command Center mounted in the door offers a 32-character full text LCD readout that displays system events and menu prompts, making it efficient and easy-to-use. TRANSFORMER AND ENCLOSURE POWERFUL ADDRESSABLE FIRE SYSTEM The 16 VAC, 56 VA wire-in transformer is factory installed and features a built-in PTC for power circuit protection. • Proven reliability suitable for commercial and industrial installations 12 or 24 VDC NAC 1 • On-Board 10/100 Network Communication • Full range of zone expansion, communication, and relay output capability 12 or 24 VDC NAC 1 • Flash Updateable: No more firmware chips to replace • Adaptive Technology™ — Cost-effective supervised cellular backup Sync Module Strobe Mini-Horn 12 or 24 VDC NAC 2 Sync Module Power Supply Digital SLC Loop 2 Any expansion device can operate on SLC Loop 1 or 2 505-12 or other 12/24VDC UL Commercial Fire Approved Power Supplies Digital SLC Loop 1 Digital Annunciator Bus 630F Fire Command Center XR150FC/XR550FC SERIES COMMERCIAL FIRE PANELS FLEXIBLE COMMUNICATION FEATURES • Up to 562 two-wire smoke detector or fire initiating zones on XR550FC • Up to 142 two-wire smoke detector or fire initiating zones on XR150FC • Up to .5 Amps 12 VDC smoke and auxiliary output with OVC protection • Up to .7 Amps 12 VDC supervised bell output • Up to 506 fully-programmable Form C relays • Serial 3 Digital Dialer or CID reporting to multiple receivers • Eight communication paths between the panel and Central StationBuilt-in remote or on-site feature upgrade capability • 12,000 event buffer • Multi-lingual menus available by user 31 FAX: 800.743.5724 • • • • Multiple on-board status LEDs Up to 100 output schedules to control relays and panel outputs 32 individual reporting areas, with common areas Output Groups: Maximum functionality–Minimum programming XR150DNFC/XR550DNFC SYSTEM FEATURES • • • • All above listed System Features On-board Ethernet connection for Network Monitoring™ Customizable check-in time and retry time Suitable for multi-site applications where the Internet or LAN/WAN is available Horn Strobe NETWORK OR CELLULAR XR550DNFC COMMUNICATION The XR150DNFC and has transitioned from dialer-focused communications to a true network and cellular communications approach by providing stronger, multi-layered panel communications that ensure a constant link between the panel and Central Station. Installers have the ability to create, configure and manage up to eight communication paths. The unique DMP Serial 3 format supports 16 or 32-character user, zone and area names to decrease the central station response time and limit dependence on automation literal tables for message conversion. Built-in 10/100 auto-sensing Ethernet connection enhances both standard and encrypted line security options. Both UDP and TCP are supported. The network option can be used as the primary or backup path to the digital dialer or cellular option. The XR150FC and XR550FC Series Panels may be used with the 263C or 263H Digital Cellular Communicator as the primary path (no backup required) for commercial fire installations. 12 or 24 VDC NAC 2 Motor Bell Additional 630F Fire Command Centers The check-in and fail time settings are programmed for five minutes. As the backup path, the 263C or 263H provides the security of a communication link that continues to function, even when land lines are cut or compromised. The communicators can be used as a standalone communicator without the need for a backup. This interface works on digital Cellular data networks over a variety of carriers in the USA and Canada. CUSTOMER SERVICE: 866.266.2826 32 FIRE PANELS EIGHT COMMUNICATION PATHS NOTIFICATION CIRCUIT Create, configure, and manage up to eight EXPANSION communication paths between the panel and Easily add NAC outputs to the XR150FC/ Central Station. Each path has its own panel XR550FC system. Up to three Class B communication programming parameters, modules can be mounted within the FACP. and can be identified as either primary or Model 865 or 866 Class B NAC Modules backup. This enables installers to configure a may be combined with a power supply to reliable communication link, offering greater provide additional 4 Amp NAC outputs. Use confidence that the panel will always be an 867 on the SLC Loop to further expand connected to the Central Station. NAC circuits. COMMUNICATION FUNCTION DIAGNOSTICS The enhanced diagnostic menu enables technicians to check network and cellular communication status, cell signal strength, and email status from the keypad. FIRE DRILL AND ONE-MAN WALK TEST OUTPUTS The XR150FC and XR550FC allow the use of two SPDT relay outputs and four open collector outputs, that may be activated by zone or system events, by schedule, through the User Menu or when a card is presented. Output Groups allow multiple outputs to activate with a single event and/or can be assigned to a particular user profile. OUTPUT SCHEDULES Achieve maximum system flexibility with 100 programmable schedules that simplify planning and operations. Control any contact-activated device with schedules that automatically regulate relays and switched-ground outputs. Users can test fire notification bells using the Fire Drill feature. A special code is also available for installers to test the system. The one-man walk test feature allows a single technician to check the MULTI-LINGUAL DISPLAYS FIRE ZONE PROGRAMMING panel response to fire, burglary, panic and For additional flexibility, keypads Program zones for fire, fire verify, fire supervisory zones. attached to the XR150FC and XR550FC retard, presignal, cross zoning, or fire panels can display keypad Status List supervisory. This flexibility allows the ability BUILT-IN PROGRAMMER and User Menu text using multiple to match individual zone characteristics to AND DIAGNOSTICS languages. The user has the option to the needs of any area in the fire installation. No programming device is required, select the language to use. enabling installers and service technicians ZONE EXPANSION to fully program the system and run STATUS LIST The XR150FC and XR550FC provide up to diagnostics from any DMP LCD keypad. To provide maximum system flexibility, 570 zones, programmable for a variety of Check the electrical state of zones, find fire zones may be programmed to fire applications. The system provides Class individual zone numbers, check the display at a specific keypad. In this B 12 VDC powered zones, two on-board LX-Bus for Missing, Overlapping and/or manner, all fire zones can be monitored and four on the 715 Module, plus eight Extra zones, and much more, all from any in one location and other zones can be panel burglary zones. Up to 60 zones are DMP LCD keypad. programmed to display and be monitored available on 15 keypad addresses and up at different keypad locations. to 100 zones are available on each built‑in FLASH UPDATEABLE LX-Bus™ using Expansion Modules. The XR150FC and XR550FC panels accept 12,000 EVENT MEMORY FIRE VERIFY Used primarily for smoke detector circuits to verify the existence of an actual fire condition. When a Fire Verify zone initiates an alarm, the panel performs a Sensor Reset. If any Fire Verify zone initiates an alarm within 120 seconds after the reset, an alarm is indicated. If an alarm is initiated after another 120 seconds, the cycle is repeated. software updates from a remote location using Remote Link™ software. When new XR150FC/XR550FC feature updates release, perform the flash update remotely. Allows the user to view the last 10,000 door accesses or 2,000 system events that occurred over the past 45 days. REMOTE LINK The Remote Link programming software takes advantage of the easy-to-use simplicity of Microsoft® Windows™. The XR150FC and XR550FC include an interface connection for installers to use to connect a laptop computer. KEYPADS 630F POWER SUPPLIES LCD Remote Fire Command EXPANSION MODULES 710 711 714 714-8 714-16 715 715-8 715-16 716 505-12/LX 505-12L 505-12A 5 Amps @ 12 VDC 5 Amps @ 12 VDC 5 Amps @ 12 VDC DMP WIRELESS 1100X 1100XH 1100R 1103 Receiver High Power Receiver Repeater Universal Transmitter, External Contact 1165 Commercial Smoke Detector 1165H Commercial Smoke/Heat Detector 1165HS Commercial Smoke/Heat Detector with Sounder 1183-135F Heat Detector 1183-135R Heat Detector 1184 Carbon Monoxide Detector Bus Splitter/Repeater Single Zone Expansion PULL STATIONS 4-zone Class-B Expansion 850 Series Pull Stations 8-zone Class-B Expansion SMOKE/HEAT DETECTORS 16-zone Class-B Expansion 2W-BLX Conventional Smoke 4-zone 2-wire smoke Expansion 2WT-BLX Conventional Smoke/Heat 8-zone 2-wire smoke Expansion 16-zone 2-wire smoke Expansion ACCESSORIES 270 Network Transient Suppressor Output Expansion, 4 Form C 277 Commercial Fire Buzzer Module relays, 4 open collector outputs 300 Four-wire Harness 717 Graphic Annunciator: 20 open collector outputs COMPUTER SOFTWARE 303 Silence/Reset Push-Button Remote Link Upload/Download 305 Plug-in Output Relay CELLULAR COMMUNICATORS Programming Software 306 Tamper Harness 263C CDMA Cellular Communicator System Link End-User Management Software 307-S Screw-On Tamper Switch 263H HSPA+ Cellular Communicator Alarm Monitoring Module 3012 Clip-On Tamper Switch AUXILIARY MODULES Command Center Module 335 Intrusion Siren 860 Relay Output Module Advanced Reporting Module 370 Lightning Suppressor 865 Style W/X Notification Account Groups Module 374 Surge Voltage Suppressor Circuit Module Link Server Application 381-2 18" Coax Extension 866 Style W Notification 431 Output Harness Circuit Module 861 Power Distribution Module 867 LX-Bus Notification CENTRAL STATION RECEIVERS Circuit Module SCS-1R Network Enabled Receiver 869 Style D Class A Initiating Compatable with Central Station Circuit Module Receivers that accept Standard CID, 893A Dual Phone Line Module DD, or DMP Serial 3 messaging SCS-VR (Virtual Receiver) Software only solution that runs on a server for network IP and cellular communications SYSTEM SPECIFICATIONS LISTINGS AND APPROVALS Primary Power (included) 16 VAC 56 VA transformer California State Fire Marshal (CSFM) Secondary Power 12 VDC Battery New York FDNY Models 365, 366, 368 or 369 Refer to the XR150FC/XR550FC Compliance Guide Output Rating (LT-1330) and specific compliance listings for installation and Bell Up to .7 Amps at 12 VDC programming requirements necessary to meet a particular Smoke and Auxiliary Up to .5 Amps at 12 VDC approval. For installations, total bell, smoke, and auxiliary cannot exceed 1.2 FCC Part 68 Amps using a 56 VA transformer. FCC Part 15 Current Draw 180mA Underwriters Laboratories (UL) Listed Enclosure: ANSI/UL 864 Fire Protective Signaling Material Cold-rolled steel (Red) For approval information, access www.dmp.com and select Compliance. ORDERING INFORMATION XR150DFC-R XR150DNFC-R XR550DFC-R XR550DNFC-R 33 FAX: 800.743.5724 XR150 Fire Control Panel XR150 Fire Control Panel with Network XR550 Fire Control Panel XR550 Fire Control Panel with Network CUSTOMER SERVICE: 866.266.2826 34 CELLULA DIGITAL CELLULAR COMMUNICATORS PRIMARY OR BACKUP PATH YOUR SOURCE FOR CELLULAR SOLUTIONS The switch is on to cellular for many reasons. In isolated locations, cellular may be the best primary communications path option. Where land lines could go down, cellular provides a reliable backup path. In critical installations where you need to eliminate the risk of cut phone or network lines, cellular is the solution. Whatever your need, DMP has the technology to create reliable panel-to-central station digital cellular communications. • Direct cellular communication enables a direct path for alarm signals from the panel to the monitoring station • Uses digital cellular CDMA, or HSPA+ data networks in the US and Canada • Transmits email (HSPA+ only) and SMS status messages to multiple recipients XR550 and 263H HSPA+ Shown with 383 Rubberduck Antenna. DIGITAL CELLULAR COMMUNICATORS CDMA & HSPA+ SYSTEM FEATURES 35 FAX: 800.743.5724 Cellular is the right choice for locations not easily reached by phone or land lines, or where there are concerns that physical communication links might be tampered with. Or, use your cellular communicator as a backup communication path, providing the security of a communication link that continues to function, even when land lines are cut or compromised. The battery backup provides continued communications even when power is lost. FULLY SUPERVISED You’re kept fully informed of system status. The unit sends full reporting messages including Zones, Areas, and Users, with all names and details included. Full supervision ensures that the cellular communication path is intact and functional. ADAPTIVE TECHNOLOGY™ XT30 and 263C CDMA Shown with 383 Rubberduck Antenna. (not to scale) • Modular add-on to XT or XR Series Panels • Plug-and-play installation and activation of add-on communication modules • Power from panel or separate power supply, with low current draw for long standby battery life • Fully supervised to ensure the health of communication • DMP Adaptive Technology™ switches communication paths while maintaining supervision if the current path becomes unavailable on the XR Series™ panels • Direct reporting to any DMP Central Station receiver with no relaying or intermediary retransmission of alarm signals Configure your DMP digital cellular communicator as the primary path, providing installation flexibility and economical options of digital cellular communication. For commercial fire applications, the 263C/263H can be used as a stand-alone communicator without the need for a backup. • Can be equipped with local or remote antenna • Check signal strength indication at the keypad • MyAccess™ Messaging features, including text message alerts from the panel, and ability to send commands to the panel via text messages • Supports the DMP App If the primary communication path is compromised or becomes unavailable, Adaptive Technology almost instantly switches to a designated backup path. Where multiple backups are available, communications can be programmed to switch to another path as necessary. The check in frequency and programming for a backup path adapt to the check in programming of the primary path. When the primary path becomes available, normal communications are restored. Adaptive Technology provides additional confidence in the integrity of your system, while protecting you from unexpected cellular service charges. DIRECT DATA TRANSMISSION COMMUNICATION REMOTE CONTROL VIA DMP APP The digital cellular communicators The App provides Apple© iPhone and transmit IP data packets directly from iPad owners, as well as Android users, the panel’s processor over the CDMA or with the ability to access a number of HSPA+ wireless data network. All of the system functions remotely via cellular messages that are capable of being sent connection. As a dealer, the App provides by the control panel are received directly the opportunity to load a company logo into by the DMP Central Station receiver. There the App. are no intermediary servers or network operation centers, and no retransmission For both residential and commercial or reinterpretation of the information. system owners, the attractive interface Direct reporting means faster response, provides fast, easy access to the most with no concerns about signals not commonly used system functions. being properly relayed or intermediate APP CAPABILITIES communication links failing. • At a glance, check system status CELLULAR SERVICE FLEXIBILITY including programmed areas. With SecureCom Cellular Service from • Arm or disarm the system in an instant DMP, you have a one-stop resource for both hardware and cellular service. DMP • Select from the Home/Sleep/Away digital cellular communicators, whether arming options for home systems. selected as original equipment in a new • Select from the All/Perimeter arming panel or added to an existing panel via an options for office systems expansion card, the unit is ready to use the SecureCom service. • Select from Area Arming Options • Tap any programmed outputs to turn After installing the panel or card, activate the them on or off. unit via Remote Link™. After programming the panel, Remote Link recommends the • Adjust lighting/thermostat/locks optimum data plan based on the level • Video capability – up to six cameras, of security, desired communication path remote viewing. configuration, and specific programming for the account. XTL SERIES The XTLC (CDMA) is available with on-board REMOTE CONTROL VIA cellular which allows for MyAccess™ MYACCESS™: SMS MESSAGING Messaging SMS message commands to DMP MyAccess lets users send be sent directly to the panel. It is also commands via text messages to available with on-board network or WiFi their panel. Residential and smaller allowing for mobile App Control. commercial users can now remotely control their systems, including the ability This powerful burglary, residential fire, to arm /disarm, control outputs, retrieve and door access panel provides cellular system status, and perform automation communication with built-in two-way functions. Each command received by the wireless. panel is acknowledged back to the user via return SMS Message. Use any model of cell phone for MyAccess Messaging. • XR500E/XR550E provides privacy for your data with DMP encryption technology • XR100FC/XR500FC have FDNY approval for network or cell primary communication CUSTOMER SERVICE: 866.266.2826 36 CELLULA 263C/263H DIGITAL CELLULAR COMMUNICATOR For existing XT & XR150|XR550 Series panels not originally configured with cellular communications, the 263 Series expansion cards let you add cellular capabilities. The 263C/263H allows alarm messages to be communicated to an SCS-1R or SCS-VR Receiver over their respective CDMA or HSPA+ networks. It provides a fully supervised alarm communication path over the network. The 263C/263H is installed in the panel enclosure and powered by the panel so no additional enclosure, power supply or battery back-up is needed*. Plug-and-play installation makes upgrading your panel quick and easy. The 263H includes a SIM card. The 263C does not include a SIM card and is activated with the MEID number. All modules are ready for activation with SecureCom Wireless. *A 381 cable is required for the XR150 | XR550 Series. The XR150FC/XR550FC Series Fire panels used with the 263C/263H Digital Cellular Communicator has earned the UL 864 listing when used as the primary path (no backup required) for commercial fire installations per NFPA 72. The check-in and fail time settings are programmed for five minutes. When used as the backup path, the 263C/263H provides the security of a communication link that continues to function, even when land lines are cut or compromised. This interface works on the CDMA/HSPA+ data networks over a variety of carriers in the USA and Canada. TECHNOLOGY OPTIONS Selecting the right Cellular Communicator Built-in CDMA XT30/XT50 XTLC 263C/263H X X XR150 | XR550 Series 37 COMMUNICATION 263C/263H SPECIFICATIONS Primary Power 12 VDC from panel Current Draw (263C) Standby 13mA Alarm13mA Current Draw (263H) Standby 24mA Alarm28mA LISTINGS AND APPROVALS 263C/263H California State Fire Marshal (CSFM) 263C FCC ID: MIVCNN0301 Industry Canada: 4160A-CNN0301 263C Verizon Certified 263H 263C/263H COMPATIBILITY PTCRB Certified (AT&T) XT Version 112 or higher & XR150 | XR550 Series Panels 263C/263H (A 381 cable is required for the XR150 | XR550 Series) New York FDNY 263H ACCESSORIES FCC ID: RI7HE910NA 381-2 18" Coax Extension Industry Canada: 5131A-HE910NA 381-12 12' Coax Extension Underwriters Laboratories (UL) Listed 381-25 25' Coax Extension 263C/263H 383 Rubber Duck Antenna ANSI/UL 294 Access Control System Units 386 Wall Mount Antenna Bracket 387-1 3dB Fiberglass Antenna w/bracket ANSI/UL 636 Holdup Alarms Units and Systems Accessory 387-2 2dB Attack Enclosure Antenna ANSI/UL 985 Household Fire Warning 387-3 3dB MEG Antenna ANSI/UL 1023 Household Burglar 387-4 4' SMA to N Extension Cable ANSI/UL 1076 Proprietary Burglar Alarm Units & Systems 387-8 8' SMA to N Extension Cable ANSI/UL 1610 Central Station Burglary 387-25 SMA TO N CABLE, 25FT, LMR195 ANSI/UL 1635 Digital Burglar 387-50 SMA TO N CABLE, 50FT, LMR195 ANSI/UL 864 Fire-Protective Signaling 9th Edition ORDERING INFORMATION (XR150 | XR550 Series Panels only) Underwriters Laboratories Canada (ULC) Listed 263C CDMA Cellular Communicator (Verizon) 263C/381-2 CDMA Cellular Communicator 263H (XR150 | XR550 Series Panels only) w/ 381-2 Cable (Verizon) ULC S304-06 Central Station Burglar 263H HSPA+ Cellular Communicator ULC Subject-C1023 Household Burglar (AT&T, T-Mobile, (263HCAN - Rogers)) ULC/ORD-C1076 Proprietary Burglar 263H/381-2 HSPA+ Cellular Communicator w/ 381-2 Cable ULC S545 Household Fire (AT&T, T-Mobile, (263HCAN - Rogers)) ULC S559-04 Equipment for Fire Receiving Centers and Systems For additional information, access www.dmp.com and select Compliance. X FAX: 800.743.5724 CUSTOMER SERVICE: 866.266.2826 38 CELLCOMSL™ ADD NETWORK COMMUNICATION TO ANY PANEL Extend the life and expand the capabilities of older panels by adding the power of advanced, digital cellular communication. With this simple communications add-on, almost every panel can take advantage of revenue-building remote system management and control features. CELLCOM SPEC • Provide central station communication over cell for any burglary, commercial fire or residential fire panel • Use Contact ID capture, 4 zones, or Bell Monitoring • CellComSLC™ and CellComSLCF enables basic remote panel control via Virtual Keypad App™ • Provides end user alerts of arming/ disarming, alarm, and other events • Add Z-Wave control of lights, locks, and thermostats with CellComSLCZ™ CELLCOMSL SERIES UNIVERSAL ALARM COMMUNICATOR SYSTEM FEATURES • Fully supervised universal alarm communication over CDMA • Fully supervised universal fire alarm communication over CDMA • Program your own account number to easily work around locked panels • Contact ID dialer capture 39 FAX: 800.743.5724 • • • • • • • Four zones or Bell Monitoring Wiring for Ademco ECP Bus Communicates with DMP SCS-1R and SCS-VR Receivers Builds customer loyalty; creates new RMR Armed/disarmed status LED Private labeling available on the rubber logo insert Two outputs WORKS WITH MOST PANELS MULTIPLE CONNECTION OPTIONS ENABLE VIDEO ON THE APP If the existing panel supports Contact ID, CellComSL communicators can be Video is no longer an expensive option. then it’s a candidate for upgrading with attached to the existing panel in a With the CellComSLC communicators, the CellComSLC or CellComSLCZ. There variety of ways. It can capture Contact you can easily add up to six wireless are no issues with lockout codes. Simply ID messages from the dialer, or connect cameras. Via the Virtual Keypad App, add the CellComSL unit to the existing the four input zones from outputs on end users can do a remote visual survey installation and program in your own the panel; or it can sense the output of their premises to confirm an alarm account number. of the bell of an existing alarm and or simply check in on children or senior communicate the appropriate message adults. Users can also capture still or AVAILABLE MODELS to the Central Station. video images. The CellComSLC provides control of basic panel security functions and video. FOUR ZONES The CellComSLCZ adds the ability to Each of the CellComSL models provide remotely interact with Z-Wave devices, four zones for connection to burglary enabling a variety of home automation control panel outputs. Zone 4 is intended features including control of lights, door for connection to the control panel bell locks, thermostats and more. output. FIRE COMMUNICATION EASY UPGRADE FOR DIALERThe CellComSLCF offers cellular fire ONLY PANELS communication on any fire control panel Older, dial-up panels have new life with via Contact ID Captures or Zone Inputs. the addition of cellular communication. Meets NFPA 72 Standard for Single Earn customer loyalty by extending the life of their existing panels, enabling Communication Technology. them to increase the ROI on their system investment and build satisfaction with the purchase decision. FULLY SUPERVISED BUILD CUSTOMER LOYALTY COMMUNICATION Avoid the possibility of customers Provides a fully supervised alarm seeking mobile intrusion alarm features communication path for burglary control from a competitor by enabling those panels over the CDMA network providing features on their existing panel with a higher speeds. CellComSL allows alarm minimal additional cost. They are less messages to be communicated to an likely to switch systems and cancel their MOBILE SYSTEM CONTROL SCS-1R or SCS-VR Receiver over the contract. When the time does come to With CellComSL communicators you CDMA network. replace the panel, they are more likely can easily update your older residential • CDMA operates on the Verizon network. to rely on you. and commercial customers to the latest FIELD PANEL UPDATES cellular communication links. With The app can be branded with your The Model 400 USB Flash Module allows cellular in place, end users can remotely organization’s logo and contact you to easily field update firmware for access their panels via the Virtual information to provide a daily reminder panels that would otherwise require Keypad App™. This makes it possible of your services. the use of a computer and a Model 399 to use their mobile device not only to Programming Harness. OUTPUTS control basic arm/disarm functions Use outputs to connect to an arming and receive alerts, but also to control zone of an existing panel for control of Z-Wave home automation devices for that panel via the App. lights, door locks, thermostats, and more with CellComSLCZ. SPECIFICATIONS Dimensions: 5.5" W x 3.75" H x 1" D Color:White Open-Collector Outputs: 2 Zones: 4 Primary Power (iComSL/SLZ): 12VDC Primary Power (iComSLF): 12-24VDC Current Draw: Alarm 210 mA Standby 210 mA ORDERING INFORMATION iComSL Network Alarm Communicator iComSLF Network Fire Alarm Communicator iComSLZ Network Alarm Communicator, Z-Wave CERTIFICATIONS For approval information, access www.dmp.com and select Compliance. CUSTOMER SERVICE: 866.266.2826 40 KEYPADS THINLINE KEYPADS VERSATILE SUPERVISED AND UNSUPERVISED OPERATION When programmed for supervised operation, the keypad occupies its own unique device address on the keypad data bus. THE MOST AFFORDABLE CODELESS ARMING AND DISARMING AVAILABLE —WITH A SLIM NEW LOOK! THINLINE SPEC 7000 Series Thinline LCD Keypads offer high- quality, cost-effective security control in a stylish, sleek new design. • Visual and audible alarm notification • Silence alarm while system remains armed • Optional integrated proximity reader • Four optional on-board fully programmable zones • Retrofit to any DMP panel ENHANCED OPTIONS 7063 and 7073 keypad proximity readers accept DMP 1300 Series proximity credentials. THINLINE™ LCD KEYPADS 7060/7063/7070/7073 FEATURES • Attractive Thinline keypad housing available in several colors • AC power and Armed LED • Large, 32-character, Liquid Crystal Display (LCD) • Suitable for access, burglary, and fire applications • Custom 16-character home or business name • Distinct fire, burglary, zone monitor, and prewarn tones • Keypad and logo backlighting turns Red in alarm conditions • Displays time of day, armed zones, and armed areas • User-adjustable brightness, tone, and volume controls • Optional backboxes for conduit or wall-mount applications • Supports “Is this a false alarm?” and Cancel/Verify™ features • Unique silence feature allows the user to silence alarm bells and still keep the system armed • Built-in diagnostics for ease of service • Simple harness connection to 4-wire keypad bus • Compatible with all DMP panels Unsupervised operation allows you to install an unlimited number of keypads set to the same device address. Increasing the number of keypads allows maximum system operating flexibility. USER-FRIENDLY MENU FUNCTIONS KEYPAD SHORTCUT KEYS DISTINCT SOUND PATTERNS Keypad shortcut keys are provided to The keypads also provide distinct sound simplify operation and allow the user to patterns for fire, burglary, zone monitor, more quickly arm, check in, monitor, exit, and prewarn that can help users identify or reset the system. One-button arming the event occurring on their system. creates the simplest keypad available. Use the one-button shortcut keys for common RETROFIT ANY EXISTING functions, or use the ATM style menu DMP SYSTEM Retrofitting is quick and easy. Thinline for advanced functions, whichever method keypads have the same footprint as existing meets the user’s needs or level of expertise DMP keypads and mount in currently with the system. installed backboxes. Thinline Series END-USER CONTROL keypads require no special modules or Each of the Thinline Series keypads provides panel upgrades. You can provide a new a simple User Options menu for adjusting look and greater functionality to an existing brightness, speaker tone, and volume. system at just a fraction of the cost of all new equipment. VALUABLE VISUAL The User Menu allows you to quickly browse through menu options. Disarming and Arming functions are fast and easy. ALARM INDICATOR MULTIPLE-KEYPAD SAVINGS Any function allowed by the user authority In a normal state, both the keypad and Install multiple keypads on the same level is simply accessed through the logo backlighting remain Green. However, wire run. Compatibility and cost savings keypad, such as silencing alarms, resetting during an alarm state, the keypad and make the Thinline Series an asset in sensors, or displaying events. logo turn Red. The change in color allows every installation. persons on-site to instantly recognize an 2-BUTTON PANIC KEYS OPTIONS alarm condition. The top row of keys can be used as The Thinline Series keypads also provide 2-button panic keys. The user simply presses Keypad Options and Keypad Diagnostics and holds two of the keys simultaneously to menus available only to system installers send either a panic, non-medical emergency, and service technicians. Enter Keypad or fire report to the Central Station. Options to set the keypad address and change the default keypad message. Test the keypad operation at any time without disabling the system. The diagnostics program tests the LCD segments and backlighting, each of the 16 keyboard keys, and the four zones on the 7070 and 7073 keypads. Red Backlighting Green Backlighting Panic Key Labels WEATHER INFORMATION Up-to-date weather information for today “IS THIS A FALSE ALARM?” AND and tomorrow will be displayed in the ™ CANCEL/VERIFY status list for Cell or Network connected In a Home/Sleep/Away or All/Perimeter panels. If the panel is not capable or system, you can CANCEL a burglary alarm supporting weather, the space will be blank. or VERIFY that a valid burglar alarm has Eight statuses are available to indicate occurred or similarly answer whether it the weather: SUNNY, CLEAR, P-CLOUDY, is a false alarm with YES or NO. Selecting CLOUDY, RAINY, SNOWY, STORMY, and VERIFY or YES manually verifies that FOGGY. VERSATILE SUPERVISED an alarm occurred and sends an alarm verification message to the central station. (Designer Series Cover) • Connect devices directly to keypad zones • View system events/user activity through keypad display 41 FAX: 800.743.5724 CUSTOMER SERVICE: 866.266.2826 42 KEYPADS UNIVERSAL PROGRAMMING TOOL ZONE DEVICE CHOICES System installation and programming can be achieved without carrying around or purchasing expensive external programmers since panel and add-on module programming is integrated into DMP Keypads. Individually program panels, an iCOM Network Alarm Router, iCOMSL Network Alarm Communicator, and other programmable add-on modules directly from the keypad. 7070/7073 FOUR EXPANSION ZONES REQUEST-TO-EXIT (REX) Connect PIRs, door and window contacts, pull stations, sprinkler tamper switches, and silent panic buttons. Plan the installation to afford the best coverage while eliminating potential problems associated with multiple wire runs. 7063/7073 CODELESS ARMING AND DISARMING PRIVATE LABELING The innovative 7063 and 7073 Thinline keypads contain an on-board DMP proximity reader that allows users to simply present their proximity credentials to the keypad to gain access to a protected area. 7073 MOMENTARY BYPASS Zone expansion is available right on the keypad where you need it the most. The four expansion zones on the 7070 and 7073 models are fully programmable Class B protection zones that can be used for a variety of fire, burglary, and access control applications. ZONE TYPE SELECTION To enable easy user exit from an area, connect a motion sensing or mechanical device to Zone 3 on the keypad. As the user trips the zone, the keypad activates the door strike allowing the user to exit the area without presenting a card or entering a user code. DMP offers dealers the option to present their company logo on the 7000 Series keypads. The logo displays on the rubber logo insert and replaces the DMP logo. The backlighted logo glows Green during normal operation and turns Red in an alarm state. To provide an entry and exit window on systems with 24-hour perimeter protection, DMP offers the momentary bypass feature. Momentary bypass allows the user enough time to enter or exit the area. If the door remains open when the timer expires, a zone open/short is sent to the panel for the keypad Zone 2. Keypad zones can be programmed using the same zone types available on the panel. Select supervised, unsupervised, night, fire, panic, exit, and emergency operation depending on the user requirements. Place Your Logo Here KEYPAD ACCESSORIES Alternate Housings (10 packs) THIN-LCD-B Black Housing THIN-LCD-I Ivory Housing THIN-LCD-P Platinum Housing THIN-LCD-B THIN-LCD-W White Housing Backboxes 695 Keypad Conduit Backbox 696 Keypad Backbox Keypad Wiring Harness 300 4-wire harness 300-5 5-wire harness 300-12 12-wire harness 300-512 12-wire harness, 5 ft. long Proximity Credentials 1306 Prox Patch™ 1351 ProxPass® External Proximity Readers PP-6005B ProxPoint® Plus Proximity Reader MP-5365 MiniProx™ Proximity Reader PR-5455 ProxPro® II Proximity Reader MX-5375 MaxiProx® Proximity Reader TL-5395 ThinLine II® Proximity Reader KEYPAD ORDERING INFORMATION The Thinline Series keypads are available in White or Ivory to complement any decor. Select from the following options: 7060-W 7063-W 7070-W 7073-W White 7060-I 7063-I 7070-I 7073-I Ivory KEYPAD MODEL FEATURES Model 2-Button Panic Red in Alarm 7060 7063 7070 7073 X X X X X X X X 4-Zones Internal Prox Reader Wiegand Input Internal Form C Door Strike Relay SPECIFICATIONS X X X X X Operating Voltage Dimensions Display Type Colors LISTINGS AND APPROVALS 12 VDC 7” W x 5.25” H x 0.5” D LCD White & Ivory COMPATIBILITY 7000 Thinline Series keypads are compatible with all DMP panels. Thinline keypads are not available in a Fire Keypad Variation. Current Draw 7060 Standby 72mA Alarm 87mA 43 FAX: 800.743.5724 7063 Standby Alarm 85mA 100mA 7070 Standby Alarm 72mA + 1.6mA per active zone 87mA + 2mA per active zone 7073 Standby Alarm 85mA + 1.6mA per active zone 100mA + 2mA per active zone California State Fire Marshal (CSFM) FCC Part 15 ID: CCKPC0086 Industry Canada: 5251A-PC0086 New York FDNY Underwriters Laboratory (UL) Listed ANSI/UL 294 Access Control System Units ANSI/UL 365 Police Connected Burglar ANSI/UL 609 Local Burglar ANSI/UL 1023 Household Burglar ANSI/UL 1076 Proprietary Burglar ANSI/UL 1610 Central Station Burglar ANSI/UL 985 Household Fire Warning ANSI/UL 864 Fire Protective Signaling 9th Edition (7070, 7073) Underwriters Laboratory Canada (ULC) Listed ULC 5545 Household Fire ULC Subject-C1023 Household Burglar ULC/ORD-C1076 Proprietary Burglar ULC S304 Central Station Burglar For additional information, access www.dmp.com and select Compliance. CUSTOMER SERVICE: 866.266.2826 44 KEYPADS GRAPHIC TOUCHSCREEN KEYPADS GRAPHIC TOUCHSCREEN REDEFINES ELEGANCE IN FEATURES AND AFFORDABILITY GRAPHIC SPEC Introducing a touchscreen keypad that will fit nicely into any residential or commercial application. • Integrated proximity reader • Brand with your dealer logo • Weather forecast • Responsive resistive touchscreen • Manage schedules on the XR Series • Manage user codes • Add and remove Z-Wave® devices Network Connected Panel Display GRAPHIC TOUCHSCREEN KEYPADS 7872/7873/9862 SYSTEM FEATURES • • • • • • • • • • Slim profile in stylish gloss black or white finish • Simple harness connection to 4-wire keypad bus 5 inch, full-color display • Connect devices directly to keypad zones Easy-to-use icon menus • Displays time of day, armed zones, and armed areas Wired keypad - 4 wire bus • Unique silence feature allows the user to silence alarm bells and still keep the system armed Interactive shield for quick arming status • Control Z-Wave® Devices via the 738Z module on Wiegand input (7873) the XT™ and XR150 | XR550 Series Panels Supports 4 zones 7872/7873 FEATURES Keypad turns Red in alarm conditions • Supports 4 zones AC power and Armed LED • Connect devices directly to keypad zones Suitable for access, burglary, and household • Displays time of day, armed zones, and armed areas fire applications • Distinct fire, burglary, zone monitor, and prewarn tones • View system events/user activity through keypad display • Supports “Is this a false alarm?” and Cancel/Verify™ features KEYPAD DISPLAY FUNCTION End users can easily set screen brightness, tone (frequency) and volume of keypad touches. After tapping the desired function, they can tap the bar graph to increase or decrease each of the settings, for tone, volume and brightness. CUSTOMIZE YOUR DISPLAY Insert a standard micro SD card in the keypad slot to transfer your dealer logo and dealer profile information to display on the keypad. When pressed, it provides your dealer contact information. SHIELD DISPLAY TOUCHPAD CONTROL VERSATILE SUPERVISED AND The end user can choose to have an audio UNSUPERVISED OPERATION confirmation tone each time a screen When programmed for supervised operation, touch occurs. the keypad occupies its own unique device address on the keypad data bus. LED indicators (Blue and Red) indicate power and armed/disarmed status, Unsupervised operation allows you to including condition of the battery. install an unlimited number of keypads set to the same device address. Increasing RED KEYPAD the number of keypads allows maximum During an alarm state, the shield on main system operating flexibility. screen turns Red. The change in color allows the user to instantly recognize “IS THIS A FALSE ALARM?” AND an alarm condition, even if the siren has CANCEL/VERIFY™ silenced. The shield remains red until reset In a Home/Sleep/Away or All/Perimeter by the user. system, you can CANCEL a burglary alarm Basic arming and disarming has never or VERIFY that a valid burglar alarm has been easier with the interactive shield icon occurred or similarly answer whether it displayed in the center of the keypad. The is a false alarm with YES or NO. Selecting shield icon has three main functions. It VERIFY or YES manually verifies that shows the arming status of the system at an alarm occurred and sends an alarm a glance. The shield's animated border verification message to the central station. will be a solid blue when armed and the interior will display the type of arming: all, UNIVERSAL PROGRAMMING TOOL perimeter, home, sleep or away. Area mode The 7800/9800 can be used for system also supported. When disarmed the area installation and programming. will be transparent with the exception of an outline of the shield. The shield allows for FOUR EXPANSION ZONES Red Graphics screen during alarm quick arming, so the user can press and Zone expansion is available right on the hold the shield down for 2 seconds and the keypad where you need it the most. The system quick arms Away and begins the CAROUSEL MENU four expansion zones on the 7872 and 7873 exit delay. The shield also provides a link The carousel menu on the main screen models are fully programmable Class B to standard arming and disarming options. offers common functions such as panic, protection zones that can be used for a chime, check-in, user menu, fire reset, variety of residential fire, burglary, and options, and easy exit™. Panic keys are access control applications. part of the carousel menu, once pressed, three icons will appear for PANIC, EMERGENCY, and FIRE. Easy Exit is only CODELESS OPERATION available while the system is armed. The built-in proximity device reader Traditional DMP shortcut keys will also operates with a variety of credentials, including cards, fobs and the DMP Prox work in the keypad screen. Patch, a small, adhesive “button” that users can attach to a wallet, phone or other When the panel is programmed in Home/ ATTENTION LIST Sleep/Away, the user will first tap on the After disarming, if an alarm on any zone item that they usually carry with them. A interactive shield to display arming options. or communication problem has occured confirmation tone signals that the credential while armed, the Main Screen may display was recognized and accepted. a yellow attention list icon at the top of the screen. When touched, the attention list displays listing the zone and event. WEATHER INFORMATION When arming, the exit timer provides a countdown for the programmed amount of time the user has to exit. The timer provides both a visual and audible notification to exit. Up-to-date weather information for today and tomorrow will be displayed on the bottom left of touchscreens that are installed with Cell or Network connected panels. Network connected panels will also display the current temperature. If the panel is not capable or supporting weather, the space will be blank. Eight icons are available to indicate the weather: SUNNY, CLEAR, P-CLOUDY, CLOUDY, RAINY, SNOWY, STORMY, and FOGGY. • Built-in diagnostics for ease of service 45 FAX: 800.743.5724 CUSTOMER SERVICE: 866.266.2826 46 KEYPADS Z-WAVE™ SUPPORT ZONE TYPE SELECTION Add up to 232 Z-Wave devices with the 738Z Keypad zones can be programmed using module on the XT and XR150 | XR550 Series the zone types available on the panel. Panels. Control your lights, locks, and Select supervised, unsupervised, night, thermostats all from the Carousel menu on fire, panic, exit, and emergency operation the Graphic Touchscreen Keypad. Create depending on the user requirements Favorites to program multiple devices to respond to a single command or panel ZONE DEVICE CHOICES Connect PIRs, door and window contacts, event like arming and disarming. residential pull stations, sprinkler tamper POWER METERS WITH Z-WAVE switches, and silent panic buttons. Plan SMART SWITCHES the installation to afford the best coverage Z-Wave devices that are plugged into Smart while eliminating potential problems Switches can be connected to the panel to associated with multiple wire runs. provide a meter reading on the keypad. Both instantaneous and accumulative readings are provided. 7872/7873 MOMENTARY BYPASS To provide an entry and exit window on systems with 24-hour perimeter protection, DMP offers the Bypass feature. Bypass allows the user enough time to enter or exit the area. If the door remains open when the timer expires, a zone open/short is sent to the panel for the keypad Zone 2. Panic Red in Alarm 4-Zones Internal Prox Reader 7872 X X X X 7873 X X X X 9862 X X Interactive Dealer Logo Main screen carousel menu: 4.13" 1. Panic 2. Chime 3. Reset 4. Favorites 5. Check-In 6 . Easy Exit 7. Options 8. Keypad 9. Thermostats 10. Doors 11. Lights 12. User Codes 13. Schedules 14. Events GRAPHIC KEYPAD ORDERING INFORMATION Two wired versions and one wireless version of the graphic touchscreen keypad are available in black or white. Arming: Tapping the shield provides the user an options screen. Disarming: Press the shield for 2 seconds and the keypad screen pops up to enter code to disarm. Enter code: User opens entry door, keypad screen pops up to enter code to disarm. 47 FAX: 800.743.5724 X 7872-B 7873-B 9862-B Black Gloss Finish 7872-W 7873-W 9862-W 9862-W/699 (with deskstand) White Gloss Finish SPECIFICATIONS Operating Voltage Dimensions (7800) Dimensions (9800) Display Type Display Size Colors LISTINGS AND APPROVALS 12 VDC 5.8” W x 4.13” H x 0.6” D 5.8” W x 4.1” H x 0.8” D Full-color graphic LCD 5.0" (15:9 diagonal) Gloss Black or White COMPATIBILITY 7872/7873 9862 XT & XR150|XR550 Panels XT, XTL & XR150|XR550 Panels CURRENT DRAW Arming: Press the shield for 2 seconds and the system quick arms and starts the exit timer, giving the user plenty of time to leave. Wiegand Input Internal Form C Door Strike Relay X 694-7800-W Retrofit Backplate (White) 695-7800-B In-Wall Backbox (Black) 695-7800-W In-Wall Backbox (White) 698-7800-B Retrofit Backplate (Black) 698-7800-W Retrofit Backplate (White) 699-7800 Deskstand Keypad Wiring Harness 695-7800-B 300-7800-5 5-wire harness 300-7800-12 12-wire harness Proximity Credentials 1351 ProxPass® External Proximity Readers PP-6005B ProxPoint® Plus Proximity Reader MP-5365 MiniProx™ Proximity Reader PR-5455 ProxPro® II Proximity Reader MX-5375 MaxiProx® Proximity Reader 5.8" Cellular Connected Panel Display Model KEYPAD ACCESSORIES MAIN GRAPHIC SCREEN Animated Weather KEYPAD MODEL FEATURES 7872 Standby Alarm 7873 Standby Alarm 9862 Standby Alarm 145mA + 1.6mA per active zone" 215mA + 2mA per active zone" 143mA + 1.6mA per active zone" 222mA + 2mA per active zone" 120mA + 1.6mA per active zone" 206mA + 2mA per active zone" 7872/7873 California State Fire Marshal (CSFM) FCC Part 15 RFID Reader FCC ID: CCKPC0131 Industry Canada ID: 5251A-PC0131 ETL Listed ANSI/UL 294 Access Control ANSI/UL 365 Police Connected Burglar ANSI/UL 609 Local Burglar ANSI/UL 1023 Household Burglar ANSI/UL 1076 Proprietary Burglar ANSI/UL 1610 Central Station Burglar ANSI/UL 985 Household Fire Warning 9862 FCC Part 15: CCKPC0132 Industry Canada ID: 5251A-PC0132 ETL Listed ANSI/UL 1023 Household Burglar ANSI/UL 1076 Proprietary Burglar ANSI/UL 1610 Central Station Burglar For additional information, access www.dmp.com and select Compliance. CUSTOMER SERVICE: 866.266.2826 48 ACCESS CONTROL 734N/734N-WIFI MODULE DESCRIPTION FASTER DOOR ACCESS 734N-WiFi The 734N and 734N-WiFi Wiegand Interface Modules allow you to add networked and/or WiFi Access control capabilities to DMP XR Series panels. • Faster door access via 10/100 network and WiFi • Connect Proximity readers directly to the 734N or 734N-WiFi • Allows codeless system arming and disarming with DMP access cards or custom options 734N/734N-WIFI SPEC The 734N and 734N-WiFi provide codeless entry plus system arming and disarming using DMP access cards or credentials; or customizable for other credentials. WiFi Connection USE EXISTING BANK OR DOOR CONTACT ZONE BYPASS The 734N and 734N-WiFi provide four CREDIT CARDS If the module is releasing an electric programmable protection zones for a strike or magnet on a protected door, a Using a swipe or insert-style reader, the variety of burglary, residential fire, and time bypass can be provided. The bypass 734N and 734N-Wifi Modules can use access control applications. Additionally, timer is programmable, allowing users existing bank and credit cards to validate the 734N and 734N-WiFi supply a Form from 20 to 250 seconds to exit through the user code and authority with the panel. C (SPDT) Door Strike relay, built-in piezo the protected door without setting off an The module offers expanded card reader with remote annunciation output, data alarm. If the door is open at the end of capabilities through programming options. to panel LED and a 4-position terminal the bypass timer, a fault generates on With the ability to read both Wiegand or for connecting external Wiegand format Zone 2. custom cards, the 734N and 734N-WiFi proximity or swipe. Includes model 333 provide more flexibility to users. ZONE 3 REQUEST-TO-EXIT suppressor for eliminating transient You can also connect a REX device, such as EASY ENTRY™ FEATURE spikes due to relay switching. a motion detector or a mechanical switch, When an access card or prox key is PROGRAMMING OPTIONS to the module Zone 3 to provide REX presented to a reader, the reader transmits capability to the system. Flexible programming options expand the the data to the 734N or 734N-WiFi Modules. module operation. With a 32-character This module validates the user's code After a user trips the REX detector or LCD keypad connected to the 734N or against panel programming and, if switch, the Form C relay releases the door 734N-WiFi, you have flexibility to: Set authorized, the panel activates the 734N allowing the user to exit without setting off door latching time for REX sites, turn and 734N-WiFi Form C door release relay. an alarm. the built-in piezo speaker on or off, read It also arms or disarms, if programmed for custom user card numbers, identify relay those functions. action modes, define custom Wiegand bits, site code position, user code position, no communication with panel, and more. CONTROL ACCESS TO SPECIFIC AREAS Users simply present their card to the reader to arm or disarm the system or open doors in those areas for which they are authorized. 734N SPECIFICATIONS Network Connection MODEL 734N/734N-WIFI NETWORK & WIFI WIEGAND INTERFACE MODULE SYSTEM FEATURES 8.5 VDC to 28.5 VDC 346mA (Includes 200mA for proximity reader) 348mA (Includes 200mA for proximity reader) 35mA at 12/24 VDC 5 VDC, 2mA max Dimensions 4.5” W x 2.75” H x 1.75” D COMPATIBILITY XR SERIES PANELS LISTINGS AND APPROVALS 734N FCC Part 15 NIST Validated Certificate #1937 ORDERING INFORMATION • Provides four programmable protection zones suitable for burglary and access applications • XR100 & XR150 support 8 doors • XR500 & XR550 support 16 doors • Custom Cards allow for 1-255 bits • Works with proximity, swipe and insert style readers • Programmable door entry strike time allows for 1-250 seconds. • Provides two auxiliary relay outputs • 12/24 VDC Power 49 Primary Power Current Draw Standby Alarm Form C Relay Zones FAX: 800.743.5724 • Built-in 10 Amp Form C (SPDT) door release relay • Keypad programmable zone bypass, card reader and relay action operations • Connect PIRs, mechanical switches, or other devices to the 734N or 734N-WiFi for a Request-to-Exit (REX) feature • Armed status output for armed display at entry door • Built-in piezo alert sounder • Remote sounder output for local annunciation • Attractive high-strength plastic housing allows mounting on walls, electrical boxes, or inside metal enclosures 734N 734N-WIFI Network Wiegand Interface Module WiFi Wiegand Interface Module PROXIMITY DEVICES Proximity Readers PP-6005B MP-5365 PR-5455 MX-5375 TL-5395 Proximity Credentials 1351 HID ProxPass® ProxPoint® Plus Proximity Reader MiniProx™ Proximity Reader ProxPro® II Proximity Reader MaxiProx® Proximity Reader ThinLine II® Proximity Reader Underwriters Laboratory (UL) Listed ANSI/UL 294 Standard For Access Control System Units ANSI/UL 1610 Standard For Central-Station Burglar-Alarm Units ANSI/UL 609 Standard For Local Burglar Alarm Units and Systems ANSI/UL 1076 Standard For Proprietary Burglar Alarms Units and Systems ANSI/UL 1023 Standard For Household Burglar-Alarm Systems Units Underwriters Laboratory Canada (ULC) Listed ULC S304 Central And Monitoring Station Burglar Alarm ULC C1076 Proprietary Burglar Alarm Units and Systems ULC C1023 Preliminary Standard For Household Burglar Alarm System Units 734N-WIFI FCC Part 15 ID: CCKPC0136 Industry Canada: 5251A-PC0136 CUSTOMER SERVICE: 866.266.2826 50 DMP WIRELESS 1100D & 1100X RECEIVERS TWO-WAY COMMUNICATION 1100 SERIES DMP ADDS A NEW DIMENSION TO WIRELESS– Superior to traditional wireless devices that just broadcast until the zone is restored, DMP 1100 Series require an acknowledgement from the 1100 Series Receiver, indicating successful communication. This smart technology ensures that each and every communication is received and efficiently processed at the panel. 900MHZ SPREAD-SPECTRUM TECHNOLOGY DMP wireless communication employs 900MHz frequency-hopping spreadspectrum to ensure clear and accurate signal transmissions without interference in practically any environment. INCREASED SECURITY TWO-WAY OFFERS INCREASED SECURITY Two-way Supervised Wireless Repeaters and Receivers from DMP deliver unparalleled flexibility and simplicity while processing every system message efficiently. • Simple programming • Superior range 1100 SERIES SPEC • Seamless integration with DMP panels and other hardwired devices Whether the installation is new construction, an upgrade, or retrofit, Two-way Wireless Repeaters and Receivers from DMP get the job done faster with less effort. Other wireless devices can take up to four hours before the system recognizes a missing device! With Two-way communication, if the receiver misses an expected supervision message, the system immediately reports the zone or output as missing, so your systems integrity and reliability are never compromised. SPECIFICATIONS LISTINGS AND APPROVALS Frequency Range 905-924 MHz Flame-retardant ABS constructed housings. California State Fire Marshal (CSFM) New York FDNY (1100R, 1100X, 1100XH) FCC Part 15 Registration ID CCK1100 1100D, 1100X CCKPC0110 1100R CCKPC0111 1100DI CCKPC0114 1100DH, 1100XH Industry Canada ID 5251A-PC0082 1100D, 1100X 5251A-PC0110 1100R 5251A-PC0111 1100DI 5251A-PC0114 1100DH, 1100XH Underwriters Laboratories (UL) Listed Listings for 1100 Series Receivers and Repeaters ANSI/UL 365 Police Station Connected Burglary Accessory ANSI/UL 609 Local Burglary Alarm Units and System Accessory ANSI/UL 1023 Household Burglar Alarm System Unit Accessory ANSI/UL 1076 Proprietary Burglar Alarm Units Accessory ANSI/UL 1610 Central Station Burglary Alarm Units Accessory ANSI/UL 985 Household Fire Warning System Accessory Additional listings for 1100D and 1100X ANSI/UL 636 Holdup Alarm Units and Systems Accessory Additional listings for 1100X, 1100XH and 1100R ANSI/UL 864 Control Units for Fire-Protective Signaling Systems ANSI/UL 346 Waterflow Indicators for Fire Protective Signaling Systems ANSI/UL 268 Smoke-Automatic Fire Detectors 1100D/1100X RECEIVER Operating Voltage Current Draw Housing Dimensions Antenna Dimensions 8.0 to 14 VDC 40mA 4.65” L x 1.4” W x 3.1” H 8.6” H 1100DH/1100XH RECEIVER DMP 1100 SERIES WIRELESS RECEIVERS Operating Voltage Current Draw Housing Dimensions Antenna Dimensions SYSTEM FEATURES 1100 SERIES RECEIVERS 1100DI RECEIVER • 1100D/1100DH/1100DI Receiver for XT Series • 1100X/1100XH Receiver for XR Series Panels • 1100R Repeater for XT, XTL and XR Series Panels 1100R REPEATER • Two-way supervised communication • Extended range with the 1100DH and 1100XH • 3-, 60- or 240-minute supervision window; selectable by zone or output to maximize effectiveness • Frequency-hopping 900MHz Spread-Spectrum technology • Attractive and durable plastic housing for all units Operating Voltage Current Draw Housing Dimensions Operating Voltage Housing Dimensions Antenna Dimensions PATENTS U.S. Patent No. 7,239,236 FAX: 800.743.5724 8.0 to 14 VDC 160mA 4.65” L x 1.4” W x 3.1” H 8.6” H 8.0 to 14 VDC 45mA 3.3” L x 1.6” W x 1.2” H 8.0 to 14 VDC 4.65” L x 1.4” W x 3.1” H 8.6” H ACCESSORIES 376 51 1100DI RECEIVER Competitively priced for This economical receiver provides the same residential or commercial basic features as the 1100D model but in a applications, the 1100D more compact unit. The 1100DI connects and 1100X Receivers anywhere on the keypad bus of XT Series allow you to add wireless panels and is suitable for either residential transmitters to DMP or small commercial applications. panels as easily as adding a keypad. Supporting up to 1100R REPEATER Extend the communication range of DMP 32 wireless transmitters wireless devices with the 1100R Wireless using the 1100D or up Repeater. Use up to eight 1100R repeaters to 500 transmitters with any DMP 1100 Series Receiver system. using the 1100X, DMP receivers satisfy all The plug-in DC power supply is backed wireless applications. up by a 24-hour battery. On-board LEDs 1100DH & 1100XH RECEIVERS provide built-in survey capability to enable single-person installation and eliminating The more powerful 1100DH and 1100XH the requirement for an external survey kit. offer the same Two-way wireless An internal case tamper switch provides capabilities as the basic 1100D and 1100X device security. models, but with the added power needed for harsh RF environments. The 1100DH installs on the keypad bus of the XT Series COMPATIBILITY XTL, XT and XR Series Panels. panel. The 1100XH installs on the wireless bus of the XR Series panels. DC Plug-in Power Supply (1100R only) CUSTOMER SERVICE: 866.266.2826 52 DMP WIRELESS 1100 SERIES 900MHZ SPREAD-SPECTRUM TECHNOLOGY DMP SMART DEVICES ENSURE MESSAGE ACKNOWLEDGEMENT DMP SMART DEVICES ENSURE MESSAGE ACKNOWLEDGEMENT Providing Double the System Security Two-Way Supervised Wireless from DMP delivers unparalleled flexibility and simplicity without sacrificing power. • Built-in device testing • Simple programming • Superior range • Seamless integration with DMP panels and other hardwired devices Whether the installation is new construction, an upgrade or retrofit, Two-Way Wireless from DMP gets the job done faster with less effort. DMP wireless communication employs 900MHz frequency-hopping spreadspectrum to ensure clear and accurate signal transmissions without interference in practically any environment. TWO-WAY COMMUNICATION DMP wireless receivers supervise for transmitters that go missing. With Two-way communication, each wireless transmitter communicates with the receiver using supervision messages. Each transmitter can be programmed for no supervision or a 3, 60, or 240 minute window providing flexibility and allowing increased security for those applications that require shorter supervision times. When the receiver does not receive any supervision messages from the transmitter for the programmed window of time, the receiver reports the zone or output as missing to the panel for display and reporting to the Central Station. The on-board LED on all 1100 Series Transmitters provides built-in survey capability to allow for single-person installations, eliminating the requirement for an external survey kit. EXTENDED BATTERY LIFE DMP 1100 SERIES WIRELESS TRANSMITTERS SPECIFICATIONS • Two-Way supervised communication • Built-in Survey LED visually confirms communications • Extended range and battery life • 3-, 60- or 240-minute supervision window; selectable by zone or output to maximize effectiveness • Frequency-hopping 900MHz Spread-Spectrum technology • Attractive and durable plastic housing for all units TRANSMITTER FEATURES • • • • Internal case tamper for added security Programmable from panel keypad or via Remote Link™ Selectable communication test intervals User-replaceable 3.0V Lithium batteries 53 FAX: 800.743.5724 1100 SERIES TRANSMITTERS • • • • • • • • • • • • • • • • • • • • • 1101/1102/1103 Universal Transmitters 1106 Universal Transmitter 1107 Micro Window Transmitter 1114 Four-Zone Expander 1116 Relay Output 1117 LED Annunciator 1118 Remote Indicator Light 1119 Door Sounder 1121 PIR Motion Detector 1126R Ceiling PIR Motion Detectors 1127C/1127W Wall Mount PIR Motion Detectors 1129 Glassbreak Detector 1131 Recessed Contact 1135 Siren, 100 dB 1135DB Siren, 110 dB 1137 Emergency Light 1139 Bill Trap 1141 Wall Button 1142/1142BC Two-Button Panic Transmitters 1145 Series Key Fob Transmitters 1148 Personal Pendant Programming each wireless device with a specific communication test interval eliminates wasteful, repetitive signalling. By eliminating multiple rounds of repetitive signals, Two-Way communication extends battery life. SIMPLE PROGRAMMING No special equipment is needed to program the system! Assign wireless transmitters to zones or outputs during panel programming with Remote Link™ or from the keypad. 1101 UNIVERSAL TRANSMITTER The Model 1101 Universal Transmitter provides Internal and External contacts that may be used at the same time to yield TWO individual reporting zones from one transmitter. This functionality makes the 1101 perfect for applications where a door and window (or any type of N/O or N/C contact) are in close proximity. 1102 UNIVERSAL TRANSMITTER Model 1102 Universal Transmitter provides the same look and reliability of the 1101 without an internal contact. Simply connect any Normally Open or Normally Closed contact to the 1102 Transmitter two-wire terminal block. 1103 UNIVERSAL TRANSMITTER Model 1103 Universal Transmitter is typically used in commercial fire or burglary door/window applications. It offers the same look and features as the 1101 transmitter, with the addition of a 470k end-of-line resistor and wall tamper switch. 1116 RELAY OUTPUT The 1116 Relay Output provides a Form C (SPDT) dry relay contact rated for 1 Amp @ 30 VDC. Program the 1116 with a slow or fast response time to fit your application. 1117 LED ANNUNCIATOR The 1117 LED Annunciator provides one remote LED that can be used to visually notify the user about conditions such as armed area annunciation, ambush alarm, burglary alarm, exit timer, entry timer, schedules, or communication failure. 1106 UNIVERSAL TRANSMITTER The 1106 Universal Transmitter is less than half the size of 1101/1102 series, providing for more mounting options and more discrete placement. This 2-input transmitter is typically used for door/window applications. The internal and external contacts can be programmed to operate at the same time, providing two independent zones from one transmitter. 1107 MICRO WINDOW TRANSMITTER This low-profile transmitter is typically used for window applications. It contains a single reed switch that detects a magnet mounted on the window. The 1107 provides survey capability to allow one person to confirm transmitter communication with the receiver before installation. A 3V coin cell battery powers the transmitter. 1118 REMOTE INDICATOR LIGHT The 1118 Remote Indicator Light provides one remote LED indicator for XR Series Panels that visually indicates when a panic alarm has been activated. Install in a break room, storage area, or anywhere not visible to the teller line or lobby where a notification LED could be used. 1119 WIRELESS SOUNDER This single-zone sounder serves as both a burglary and audible alert device, sending a signal to the panel while creating an audible tone. In retail/commercial applications, it provides a lower-cost alternative to sounders available as an add-on with crash bars. Connecting the zone input to a door contact allows it to trigger the sounder immediately. 1114 FOUR-ZONE EXPANDER The 1114 Four-Zone Expander increases the number of reporting zones available on DMP panels. The four zones can be used with burglary and non-powered devices. CUSTOMER SERVICE: 866.266.2826 54 DMP WIRELESS 1121 PIR MOTION DETECTOR The Model 1121 PIR (Passive Infrared) Motion Detector with Pet Immunity is suitable for most residential or small commercial applications. With a generous coverage area of 90° 50' X 50', the 1121 is a favorite among security professionals. 1126 SERIES PIR MOTION DETECTORS The 1126 Series PIR Motion Detectors are compact wireless motion sensors. Offering a 360°, Spot, Curtain, or Wide Angle version makes the 1126 Series flexible for a variety of ceiling mount applications. To save battery life, select YES for Disarm Disable in Zone Programming. This allows the 1126 PIR to be disabled for Night and Exit type zones while the area is disarmed. 1127 WALL-MOUNT PIR MOTION DETECTORS The 1127C curtain PIR covers a 50-foot detection area using a Fresnel lens. The 1127W wide-angle PIR covers a 36-foot by 84-degree angle area using a Fresnel lens, with pet immunity up to 40 pounds. Both versions exhibit excellent R.F.I. and noise immunity, and include Disarm Disable. 1129 GLASSBREAK DETECTOR Designed to detect the shattering of framed glass mounted in an outside wall, this sensor is also suitable for armor-coated glass. The 360° microphone can detect through blinds and light drapes within a 12’ range and also recognizes the “quiet break” favored by experienced intruders. Ideal where hardwired acoustic sensors are impractical, the 1129 incorporates Pattern Recognition Technology™ to ignore most false alarm sounds. 1131 RECESSED CONTACT The 1131 Wireless Recessed Contact provides concealed protection for doors, windows, or any other application needing a discreet contact. The 1131 transmits Normal, Alarm, and Low Battery conditions. 55 1135 SIRENS The 1135 Wireless Siren Series makes it possible to quickly and easily place one or more sirens as part of an installation. With both residential and commercial end users, this battery powered siren is an easy, add-on sale to customers who want the extra security provided by locating sirens in several interior locations. The 1135 includes a cover tamper and survey LED, and comes with batteries. The 1135 has a volume of 100 dB, while the 1135DB offers 110 dB. 1137 EMERGENCY LIGHT The 1137 Emergency light activates when an alarm is triggered or any other panel output programming. This wireless LED light can be used for indoor path lighting or alarm notification. 1139 BILL TRAP Designed to provide a silent alarm option for cash drawer operators, the 1139 holds a trapped bill below a stack of bills. When the trapped bill is removed, a panic alarm is sent to the receiver. 1141 WALL BUTTON The 1141 Wall Button is a one-button wireless transmitter designed to be wall-mounted. When pressed, a message is sent to the panel. The 1141 also provides an LED that can be programmed to provide visual indication that a signal has been transmitted. The wall button can be used as a panic button, and when programmed in output options as a garage door, light switch, door release, arming or disarming button. 1142 & 1142BC TWO-BUTTON HOLD-UP TRANSMITTER The Model 1142 and 1142BC Two-Button Hold-up transmitters are typically used as a panic alarm, but with a little imagination this transmitter can be used for a multitude of applications. The optional belt clip offers mobile protection. Permanently mount the 1142 in an under-the counter location with the included screws for UL installations. FAX: 800.743.5724 KEY FOB TRANSMITTERS The 1145 Series Key Fob transmitters are portable, water resistant, and designed to be clipped to a keychain or lanyard. The key fob LED provides visual acknowledgement when a button is pressed and responds to each separate operation with specific color‑ coded LED status displays. 1145-4-B 4‑button 1145-2-B 2-button 1145-1-B 1-button 1145-1-BP KEY FOB WITH BUILT-IN PROX The 1145-1-BP is a 1-button wireless key fob transmitter that includes a built-in proximity crediential for access control. This accessory now meets two requirements controlling the system for such functions as arming, disarming or panic, as well as being able to arm or disarm via an alarm system or as an access control credential. 1148 PERSONAL PENDANT The 1148 Personal Pendant is a one-button, wireless emergency transmitter designed to be worn as a wristband or on a breakaway lanyard. The 1148 is programmed as a wireless zone and can be used to activate an emergency alarm at the receiver. The 1148 features a permanently sealed, water-resistant design. 9000 SERIES KEYPAD The 9060 and 9063 Wireless Keypads are fully functioning, supervised keypads that provide installation flexibility. These fullfeature keypads include four 2-button panic keys and an internal speaker. The backlit keyboard is easy to read, and both the keyboard and logo turn Red in alarm conditions, providing a visual alert. Both Keypads have a 32-character display, and can be programmed with a 16-character home or business name. The 9063 keypad also includes a built-in proximity reader for codeless arming and disarming. Shown with Keypad Desktand (699) 1101/1102/1103 TRANSMITTER SPECIFICATIONS Battery Life Expectancy 5 years Dimensions Transmitter Case 3.3” L x 1.6” W x 1.2” H Mounting Bracket 2.5” L x 1.3” W x 0.1” H (1101/1102 only) Magnet Housing 1.5” L x 0.5” W x 0.7” H 1106 TRANSMITTER SPECIFICATIONS Battery Life Expectancy 5 years Dimensions Transmitter Case 1.79” L x 1.69” W x 0.84” H Standard Magnet Housing 1.35” L x 0.38” W x 0.43” H Commercial Magnet Housing 2.25” L x 0.38” W x 0.34” H 1107 TRANSMITTER SPECIFICATIONS Battery Life Expectancy 2 years Dimensions Transmitter Case 2 5/8” L x 1” W x 5/16” H Standard Magnet Housing 2 1/8” L x 3/8” W x 5/16” H Commercial Magnet Housing 2 1/8” L x 3/8” W x 5/16” H 1114/1116/1117/1118 SPECIFICATIONS Battery Life Expectancy 1114 3 years 1116/1117/1118 5 years (Slow Response) Dimensions 4.65” L x 3.1” W x 1.4” H 1119 SPECIFICATIONS Battery Life Expectancy 2 ½ Years (Slow Response) 3 Months (Fast Response) Dimensions 4.65” L x 3.1” W x 1.4” H 1121 PIR SPECIFICATIONS Battery Life Expectancy 3 years Dimensions 4.8” L X 2.5” W X 1.45” H Detection Range 90° 50 x 50 feet Mounting height 4.9 to 8.2 feet 1126 SERIES PIR SPECIFICATIONS Battery Life Expectancy 3 years Dimensions 4.0” DIA x 2” H Mounting height 6.5 to 18 feet 1127 SERIES WALL-MOUNT PIR SPECIFICATIONS Battery Life Expectancy 5 to 7 years Dimensions 2.7” W x 1.77” D x 4.33” H Mounting height 8 feet 1129 GLASSBREAK SPECIFICATIONS Battery Life Expectancy 3 years Dimensions 4.25” L x 3.15” W x 1.75” H Microphone Omnidirectional Electret 1131 SPECIFICATIONS Battery Life Expectancy 5 years Dimensions Housing 4.175” L X .55” DIA Housing Flange 1.7” L X .80” W Magnet Housing 0.7” L X .55” DIA 1135/1135DB SIREN SPECIFICATIONS Battery Life Expectancy 3 Years Dimensions 4.5” L x 4.5” W x 1.25” H 1137 SPECIFICATIONS Battery Life Expectancy Dimensions 2 years 3" H x 2.5" W x .75" D 1139 BILL TRAP SPECIFICATIONS Battery Life Expectancy 1 year using 2 batteries Dimensions 5.375” H x 2.625” W x .625” D 1141 WALL BUTTON SPECIFICATIONS Battery Life Expectancy 4 years Frequency Range 903-927 MHz Dimensions 3.3” L x 1.6” W x 1.2” H 1142/1142BC TRANSMITTER SPECIFICATIONS Battery Life Expectancy 5 years Dimensions Transmitter Case 3.3” L x 1.6” W x 1.2” H Belt Clip 1.9” L x 0.9” W x 0.3” H 1145-4-B/1145-2-B/1145-1-B/1145-1-BP KEY FOB SPECIFICATIONS Battery Life Expectancy 2 years Dimensions 1.98” H x 1.98” W x 0.6” D 1148 PERSONAL PENDANT SPECIFICATIONS Dimensions 1.6" L x 1.2" W x 0.45" H Battery Life Approx. 2.5 to 3 years Non-removable WIRELESS KEYPADS 9060/9063 THINLINE KEYPAD SPECIFICATIONS Standby Battery Time 24 Hours Dimensions 7” W x 5.25” H x 0.5” D 9862 TOUCHSCREEN KEYPAD SPECIFICATIONS Standby Battery Time 12 Hours Dimensions 5.8” W x 4.135” H x 0.6” D COMPATIBILITY XTL, XT, and XR Series Panels ACCESSORIES CR123 CR2032 CR2450 CR17450 CR12600 371-500 376 378 699 777 9000BAT PATENTS U.S. Patent No. 7,239,236 3.0V Lithium Battery 3.0V Coin Cell Lithium Battery (1145 series only) 3.0V Coin Cell Lithium Battery (1139 only) 3.0V Lithium Battery Pack (1126 Series only) 3.0V Lithium Battery (1131 only) 12 VDC Plug-in Power Supply (9060/9063 only) DC Plug-in Power Supply (1114-1118 only) Barrel Connector with Cord (1114-1118 only) Keypad Deskstand (9060/9063 only) Protective Keypad Cover (9060/9063 only) Replacement Standby Battery (9060/9063 only) LISTINGS AND APPROVALS California State Fire Marshal (CSFM) FCC Part 15 Industry Canada For additional approval information, access www.dmp.com and select Compliance. CUSTOMER SERVICE: 866.266.2826 56 DMP WIRELESS 1100 SERIES LIFE SAFETY 900MHZ SPREAD-SPECTRUM TECHNOLOGY DMP wireless communication employs 900MHz frequency-hopping spread-spectrum to ensure clear and accurate signal transmissions without interference in practically any environment. DMP SMART DEVICES ENSURE MESSAGE ACKNOWLEDGEMENT WHEN IT'S MOST IMPORTANT TWO-WAY COMMUNICATION DMP wireless receivers supervise for transmitters that go missing. With Two-Way communication, each wireless transmitter communicates with the receiver using supervision messages. Each transmitter can be programmed for no supervision or a 3, 60, or 240 minute window providing flexibility and allowing increased security for those applications that require shorter supervision times. When the receiver does not receive any supervision messages from the transmitter for the programmed window of time, the receiver reports the zone or output as missing to the panel and Central Station. PROVIDING DOUBLE THE SYSTEM SECURITY Two-Way Supervised Wireless from DMP delivers unparalleled flexibility and simplicity without sacrificing power. • Built-in device testing • Simple programming SIMPLE PROGRAMMING No special equipment is needed to program the system! Assign wireless transmitters to zones or outputs during panel programming with Remote Link™ or from the keypad. 1161 & 1162 RESIDENTIAL SMOKE DETECTORS The Model 1161 Smoke Detector with Sounder, and 1162 Smoke/Heat Detector with Sounder are wireless detectors for residential applications. Model 1162 also offers a built-in fixed and rateof-rise heat detector. The fixed temperature function responds to the 135° temperature setting and the rate‑of‑rise function detects and responds to a rapid temperature increase. When tripped, either function sends an alarm to the panel. 1164 RESIDENTIAL/COMMERCIAL SMOKE DETECTOR The Model 1164 smoke detector includes synchronized sounders so when more than one 1164 is installed on a system, the alarm cadence will synchronize. Any fire zone tripped on the panel will cause the sounders to initiate. The 1164 also includes a tamper switch that sends a trouble signal when the detector is removed from the mounting base. Up to 572 units can be installed on one system. The on-board LED on all 1100 Series Transmitters provides built-in survey capability to allow for single-person installations, eliminating the requirement for an external survey kit. EXTENDED BATTERY LIFE Programming each wireless device with a specific communication test interval eliminates wasteful, repetitive signaling. By eliminating multiple rounds of repetitive signals, battery life is extended. 1183 WIRELESS HEAT DETECTOR • Superior range • Seamless integration with DMP panels and other hardwired devices 1184 CARBON MONOXIDE DETECTOR The 1184 Carbon Monoxide Detector is the ideal choice for difficult-to-wire locations, applications where room aesthetics are critical, or where hazardous materials are present. The sensor provides an early alert of potentially harmful levels of carbon monoxide in residential or commercial installations. In addition, it also transmits trouble, tamper, and low-battery messages to the panel. COMMERCIAL FIRE APPROVED DEVICES FOR USE WITH THE XR100/XR500 1103 UNIVERSAL TRANSMITTER Model 1103 Universal Transmitter is typically used in commercial fire or burglary door/ window applications. It offers the same look and features as the 1101 transmitter, with the addition of a 470k end-of-line resistor and wall tamper switch. 1165/1165H/1165HS COMMERCIAL SMOKE DETECTORS The Model 1165 Smoke Detector, 1165H Smoke/Heat Detector, and 1165HS Smoke/ Heat Detector with Sounder include a tamper switch that sends a trouble signal if the detector is removed from the mounting base. The 1183 Series is a reliable, ceiling-mount heat sensor available in two versions. The 1183135F responds if the temperature exceeds 135°. The 1183-135R adds a rate-of-rise feature that responds if the temperature increases by 15°F per minute or more. Whether the installation is new construction, an upgrade or retrofit, Two-Way Wireless from DMP gets the job done faster with less effort. 1103 TRANSMITTER SPECIFICATIONS Battery Life Expectancy Dimensions Transmitter Case Magnet Housing DMP LIFE SAFETY DEVICES 1100 SERIES WIRELESS SYSTEM FEATURES 1100 SERIES TRANSMITTERS • Two-Way supervised communication • 1103 Universal Transmitter • Built-in Survey LED visually confirms communications • 1161/1162 Residential Smoke Detectors • Extended range and battery life • 1164 • 3, 60 or 240-minute supervision window; selectable by zone or output to maximize effectiveness Residential/Commercial Smoke Detector with synchronized sounders • 1165/1165H/1165HS Commercial Smoke Detectors • Frequency-hopping 900MHz Spread-Spectrum technology • 1183-135F/1183-135R Heat Detectors • Attractive and durable plastic housing for all units • 1184 Carbon Monoxide Detector PATENTS 5 years U.S. Patent No. 7,239,236 COMPATIBILITY 3.3” L x 1.6” W x 1.2” H 1.5” L x 0.5” W x 0.7” H XT and XTL Series Panels: 1103, 1161, 1162, 1164, 1183-135F, 1183-135R, 1184 XR Series Panels: 1103, 1161, 1162, 1164, 1165, 1165H, 1165HS, 1183-135F, 1183-135R, 1184 1161/1162/1164/1165/1165H/1165HS DETECTOR SPECIFICATIONS Battery Life Expectancy Dimensions Detector Base 1 year FREQUENCY Frequency Range 5.6” x 2.4” 5.4” x 0.46” ACCESSORIES 1183-135F/1183-135R DETECTOR SPECIFICATIONS Battery Life Expectancy Dimensions Detector Heat Alarm Specifications Rate-of-Rise Fixed Drift Compensation Adjustment 2 years 5.8” x 2.2” 15°F/min > 105°F 135°F ± 5°F CR123-FIRE 905-924 MHz 3.0V Panasonic Lithium Battery (for commercial fire devices) CERTIFICATIONS FCC Part 15 Registration ID CCKPC0104 IC Registration ID 5251A-PC0104 For additional approval information, access www.dmp.com and select Compliance. 0.5%/ft. max 1184 DETECTOR SPECIFICATIONS Battery Life Expectancy Dimensions 57 FAX: 800.743.5724 2 years 5.8” x 2.2” CUSTOMER SERVICE: 866.266.2826 58 MOBILE PLATFORMS MOBILE PLATFORMS VIRTUAL KEYPAD APP™ East Offices & Warehouse are ARMED: ENHANCED VIDEO VERIFICATION CUSTOMER SETUP Setting a customer up to use the DMP App is a three-step process, accomplished from the SecureCom Admin Login. After adding a user as a “new customer”, the customer will automatically receive an easy-enroll email. Tap "West Offices" to ARM that specific area only. Mobile platforms provide you with the tools you need to build strong connections with your customers. Dealers can invite their customers to NOTIFICATIONS Users can set their own alerts by selecting begin using this App on their iPhone, iPad, the message category in push notifications. or Android to give them control of their Users can view notification history. security system. The DMP App allows them to arm or disarm, and to check the status of their cellular or network connected DMP security system from anywhere they have cell or WiFi service. They can also access any Z-Wave home control devices programmed through their DMP panel and DMP cameras. • Manage user codes Users are prompted for their system user code. THE TECHNOLOGY TO KEEP YOUR CUSTOMERS CONNECTED. The User can now launch the App directly from the Alarm Push Notification into a screen that has the video camera views available which will allow video verification of an alarm. The user can simply respond to the, “Is This A False Alarm?” question displayed within that screen. Users can view 10 second clips of video recorded upon alarm. • Schedules: manage Z-Wave®, Favorites, outputs & arming schedules. • False alarm video verification MANAGE USERS Users have the ability to add, remove, or A Burglary Alarm Push Message displays edit users from the user settings. Edit on a smart phone when the system goes into user permission if you are a 'MASTER' alarm. Tap on the message to immediately user. • Exclusive Rooms feature provides end users the easiest control screen available ALARM NOTIFICATION • Control/manage multiple systems from the same App • The Virtual Keypad App provides control of end user systems using their smart phone. open the app. HOME is armed: Users can touch the dealer logo anywhere it appears on the app and be taken to the dealer contact screen. This screen can also be programmed to link to the dealer's social media sites. Virtual Keypad App™ IS THIS A FALSE ALARM? (Animated Shield) MOBILE PLATFORMS: CELLULAR SYSTEM FEATURES VIRTUAL KEYPAD APP™ • Arm, disarm, and check system status • Selectively arm and disarm areas • Turn outputs on and off • Check history & receive push notifications • User Code Management • Ability to customize the App with your company logo, contact information, and dealer social media links • Supports Z-Wave® Control, Favorites, Actions and Rooms • Geofences trigger Z-Wave Favorites & Smart Arming • Supports remote camera access for up to 6 cameras • System user code required to connect to App • Door control & lock down feature (XR Series) • Now with CellComSLCZ use the App to control any panel or add Lifestyle Features to any existing system. • Notification of faulted zones when arming • All faulted zones will display upon arming. • Sensor Activity push notifications for up to 10 zones 59 FAX: 800.743.5724 Tap "DISARM" to disarm the system. OFFICE is armed: Tap "DISARM" to disarm the system. Once the User Code is entered, the message "IS THIS A FALSE ALARM?" displays. If NO is tapped, it verifies that the alarm is not false, the system will not disarm, and the Central Station will alert authorities. If YES is tapped, it cancels the alarm, the system will disarm, and the Central Station will be notified the alarm was cancelled by the user. Users can view thumbnails which change each second representing a live view. AREA ARMING/DISARMING For residential or commercial systems that include areas, end users can selectively arm, disarm or check the status of any area from their smart phone with the tap of a button on their screen. This enables them to maintain protection for certain areas while allowing access to only the selected areas. CUSTOMER SERVICE: 866.266.2826 60 MOBILE PLATFORMS SCHEDULES (CONT.) FAULTED ZONES When a faulted zone is encountered during the arming process, the system will display an Alert Message listing the faulted zone(s) and options for Okay, Bypass or Stop. OKAY will force arm the faulted zone. A zone that is force armed is restored into the system if it later returns to normal. BYPASS will bypass all faulted zones. STOP will stop the system from arming. A zone that is bypassed remains bypassed until the system is disarmed. Z-WAVE FEATURES WITH THE APP In addition to the security-related controls provided via the app, end users can also use the app’s graphic interface to control any of their installed Z-Wave devices, including lights, appliances, door locks, thermostats, and more. Z-WAVE FAVORITES The Favorites feature lets them program multiple devices to all respond to a single command. For example, the Favorite called “Movie Night” could lock the exterior doors and close the garage door, then adjust the temperature and dim the lights in the family room to the desired level. Favorites can also be placed on a schedule. Z-WAVE ROOMS WITH A VIEW The Rooms feature lets users quickly and easily create graphic controls for Z-wave devices in rooms or areas. After taking a photo or viewing a live camera stream on their smart phone, viewers can place hotspots corresponding to one or more Z-Wave devices available. Then they can select that room from the app screen and touch any hotspot to access the controls for that device. Rooms List View Rooms Screen Create a schedule screen When using the live camera stream, users can receive live confirmation of Z-Wave device activation. LOCKDOWN Lockdown is available for the XR150/XR550 panels by tapping on lockdown. All door devices programmed as a public door along with Z-wave Locks will lock. Lights Screen With Favorite Actions, panels can be programmed to trigger Favorites upon arming and disarming events. SCHEDULES This tab is only shown if Schedules are activated by installer programming. Schedules allow the user to program times to auto arm and disarm the system. Users can add, edit or delete schedules for arming, area arming, outputs and favorites. CONTROL OUTPUTS End users are increasingly integrating their control panel with other technology and systems via outputs. Each output can be programmed to appear as a button in the app. End users can control outputs such as watering systems, garage or overhead doors, and lighting by turning them ON or OFF with a slide of their button. VIDEO CAMERAS End users can remotely access the DMP wireless interior and exterior IP video cameras via the app. They can select any of up to six cameras and remotely view the images on their smart phone or tablet. In addition to automatically recording video based on an event (e.g. camera detects movement), they can set their recording preferences to 'Record On Alarm' or 'Record Only When Armed' as well as view live video. Thermostat Screen Cameras Screen COMPATIBILITY Virtual Keypad App Z-Wave® Cameras XTL, XT Series, & XR Series Panels, and the CellComSL/iComSL Series XTL, XT, & XR150 | XR550 Series Panels, and the CellComSL/iComSL Series XTL, XT, & XR150 | XR550 Series Panels, and the CellComSL/iComSL Series Note: All cellular services require a SecureCom Wireless, LLC activation. Visit www.securecomwireless.com. Lights are ON: Slide buttons left to turn them OFF. Door Screen 61 FAX: 800.743.5724 CUSTOMER SERVICE: 866.266.2826 62 MYVIRTUALKEYPAD.COM WEB-BASED CONTROL FOR HOME AND COMMERCIAL ALARM SYSTEMS Give your customers the ability to remotely control their security systems over the internet. The Virtual Keypad Browser™ makes it convenient for users to access commonly used security functions available via their keypad and more: BRANDED INTERFACE Just as with the Virtual Keypad App, you can upload your logo so your customers will be reminded of the serivce you provide every time they log into MyVirtualKeypad.com. ELEGANT USER INTERFACE Just like the Virtual Keypad App, the browser provides users with a clean, elegant, easy-to-use interface. Controls are logically arranged in a simple tab system, with all functions just a click away. It even includes a handy, two-day weather report as part of the display. RED ALARM STATUS A red shield icon will display if a burglary alarm is occurring when the user chooses the Arming tab. The background and banner of the website also change to red to indicate the alarm. When the system is disarmed, the graphics return to blue. SCHEDULES The Schedules tab allows users to add, edit, or delete schedules. Schedules affect arming, area arming, outputs, doors, and favorites. When the tab is selected, all the schedules assigned to the current system are listed. Clicking Refresh will reload the panel information that was updated at a keypad or Remote Link™/System Link™. • Arming/Disarming • Control lights, locks, and thermostats • View and record video • Manage system users and schedules • Manage lockdown on the XR150 | XR550 series panels. • Browser and shield turn red in alarm VIRTUAL KEYPAD BROWSER™ VIRTUAL KEYPAD APP™ • Dealers can manage customers and users from the Secure Dealer Admin area • Manage user codes and privileges • Works from any Internet-connected computer using most popular browsers • Local weather forecast • Elegant interface with easy-to-use tabbed feature layout FAULTED ZONE When a faulted zone is encountered during the arming process, the system will display an Alert Message listing the faulted zone(s) and options for Okay, Bypass or Stop. OKAY will force arm the faulted zone. A zone that is force armed is restored into the system if it later returns to normal. BYPASS will bypass all faulted zones. STOP will stop the system from arming. A zone that is bypassed remains bypassed until the system is disarmed. XT Schedules Main List • Manage multiple systems from a single log-on • Notification of faulted zones when arming • Log on to MyVirtualKeypad.com with log in and system user code. • View history reports of system events when 'Notifications' are enabled in app settings on a smart phone XT Area Arming pop-up window Faulted Zones pop-up window 63 FAX: 800.743.5724 CUSTOMER SERVICE: 866.266.2826 64 LOCKDOWN Lockdown is available for XR150 | XR550 panels by clicking the Lockdown button. All door devices programmed as a public door and Z-Wave Locks will lock or unlock on the system with a single click. VIDEO CAPABILITIES The user can incorporate up to six cameras, interior and exterior, wired and wireless, in their system. Via the Virtual Keypad Browser, they can selectively monitor any of the cameras and record video. This improves security by enabling them to do a remote “walk-around,” either from across town or from their bedroom. They can also check in on latchkey children or seniors. Once recorded, the user can opt to have the video clips emailed to them. COMMERICAL AND RESIDENTIAL APPLICATIONS Business owners appreciate the ability to manage their security from a browser, whether they are in the office, at home, or on the road. They can easily access multiple business locations by choosing the desired system from the dropdown list. Edit User Codes pop-up window Select System drop down menu XR System Schedules pop-up window HOME AUTOMATION FEATURES With Z-Wave® added to the system, the user has the ability to control connected lights, thermostats, exterior door locks, and other Z-Wave enabled devices. Their laptop can be become a wireless control center for their entire home or business. The automation capabilities include Favorites features. Users can define a set of parameters for their security system and multiple Z-Wave modules, then give that set an easily remembered name for one-click control. They could create the “Good Night” favorite, for example, that would turn out or dim connected lights, lock doors, adjust the thermostat and arm the system, all with one click. Residential users also appreciate the ability to control their system from a computer anywhere in their home, or from an Internet-connected computer while they are away from home. Six cameras on the main Video screen View or record live video Z-Wave Favorites List SIMPLE USER OPERATION Users log in with their email and password provided by the dealer. After entering their user code, they can select the system they want to control from the drop-down list of available systems. Forgotten passwords are easily retrieved by user request. A new, temporary password will be emailed to their account address so they can do a self-reset. Users can change passwords. 65 FAX: 800.743.5724 MANAGE USER CODES You can configure accounts to include User Codes Management. This provides the system manager/owner with access to all authorized system users, with the ability to add, delete, and modify users and edit their codes. Users List For XT/XTL Series systems, the system manager can assign authority levels to each user (Master: Full authority or Arm Only authority). They can also assign users as Temporary, which are automatically deleted in seven days. For XR150/XR550 Series panels, the system manager can assign up to four profiles, each with defined capabilities. In Remote Link™ and System Link™, users are then assigned to one of these profiles. For Temporary users, the system manager can specify the date and time when the rights will expire. HISTORY REPORT When notifications are enabled in app settings on a smart phone, users can review system activity from the History tab. Messages include: • Alarm Events • Arm/Disarm or Open/Close Events • Troubles • Sensor Activity System History COMPATIBILITY XTL, XT & XR Series Panels and the CellComSL/iComSL Series Use standard web browsers. • Internet Explorer® 10 & 11 • Safari 6 & 7 • Firefox® 27 & 28 • Google Chrome® 32 & 33 CUSTOMER SERVICE: 866.266.2826 66 HOME CONTROL 738Z Z-WAVE TECHNOLOGY SIMPLIFY HOME AND SMALL COMMERCIAL CONTROL WITH Z-WAVE Add the DMP 738Z module to the XT, XTL, and XR150 | XR550 DMP panels to provide mobile control over lighting, HVAC, doors and more via plug-in controllers. 738Z SPEC • Relies on Z-Wave® technology - the widely used standard for home automation • Simple to install, program, and operate • Control devices remotely via DMP mobile applications • Creates many new RMR opportunities • Lighting, locks, heating/cooling and more 738Z Z-WAVE MODULE SYSTEM FEATURES • Control up to 232 Z-Wave devices • Remotely lock/unlock doors and check lock status • Wireless, low-energy mesh radio technology easily travels through walls, floors, and cabinets • ‘Favorites’ allows for programming multiple devices into a single button for easy use. • Enables remote control of connected devices via mobile applications - MyAccess™ and Virtual Keypad™ App • ‘Rooms’ enables photographic control of rooms via hotspots. • Turn lights ON/OFF and adjust brightness • For use in any residential installation as well as smaller commercial applications • Fully adjust heating/cooling systems from Heat, Cool, Auto and Off • Value-added features provide new RMR opportunities • Adjust Thermostat temperature to set point. • Local temperature on the Virtual Keypad™ Thermostat Screen ADD FUNCTIONS TO ALARM Z-Wave is emerging as the industry standard SYSTEM ARMING OPTIONS for easy-to-install Home Automation for DMP panels include the convenience of lighting, HVAC, appliances and many more programmable arming modes. Residential devices in residential and small commercial system owners can select from Home, applications. The technology uses a lowSleep, or Away while commercial users power RF radio signal with a device-tocan select All or Perimeter. The 738Z device range of approximately 65’. The makes it possible to combine additional lighting and appliance control modules device settings with each arming mode. serve as a mesh network, sending and receiving commands to all surrounding When set to Sleep, a home system can lighting and appliance control modules, be programmed to automatically lock increasing the range and reliability of the designated doors, turn on or adjust the control network. Thermostats and Locks do desired interior and exterior lighting, and not perform this function. set the thermostat back. When there is an alarm, the system can be programmed to automatically turn on all lights. BUILDING-BLOCK APPROACH The 738Z makes it possible to have most NEW RMR OPPORTUNITY of the benefits of an expensive, custom Customers will be eager for the features control system at a significantly lower made available through the 738Z. These cost and with much more flexibility. Users features can be provided as a valuecan control anywhere from one to 232 added option to end users, provided at an connected Z-Wave devices by name. They additional monthly cost. can start by controlling a few lights and easily add other devices over time. The modular approach used with the 738Z makes it possible to offer various levels of Because the technology is wireless, there features with incremental pricing. Create are virtually no limitations on where packages that include certain control to place the controllers. The extensive features at different price points or take an interoperability of the technology ensures à la carte approach that allows end users that users can create a system tailored to create a customized control system at a exactly to their needs. The flexibility flat, per-device monthly fee. of the controllers makes it possible to reconfigure the system at will, selecting TAKE MOBILE CONTROL The 738Z greatly expands the power of different lights or devices to control. DMP mobile remote features. The DMP MyAccess™ Feature sand Virtual Keypad Dealers have total control over which App make it possible for the system Z-Wave devices to offer and support. If owners to remotely control their systems, you choose to offer remote door locks, including the control of programmed but you don’t want to be involved with outputs. lighting and thermostats, then you can tailor your offering accordingly. You can also customize the DMP Virtual Keypad app to only enable the devices and features you want to promote and support. This customized approach is supported by the assortment of DMP marketing brochures and collateral. There are pieces tailored to each individual Z-Wave device. MYACCESS™ SMS COMMANDS MyAccess includes the following new commands in addition to the standard alarm system control commands. • List locks that are unlocked - text ‘Status locks’ • Lock a specific lock - text ‘Lock (name)’ • Unlock a specific lock - text ‘Unlock (name)’ • List lights that are on - text ‘Status lights’ • Turn on a specific light - text ‘Turn on (name)’ • Set a specific dimmer level xx - text ‘Turn on (name) (level)’ • Turn off a specific light - text ‘Turn off (name)’ • List status of all thermostats - text ‘Status thermostats’ • Set the thermostat to Cool or Heat with this temperature: - text ‘Set (name) cool (temp)’ - text ‘Set (name) heat (temp)’ • Set thermostat fan to Auto or On: - text ‘Set (name) fan on’ - text ‘Set (name) fan auto’ • Activates a programmed Favorite, controlling multiple devices with a single command: - text ‘ACT (favorite name)‘ For a list of all available commands, text ‘Z-Wave help.’ In addition to controlling connected devices and systems, users can also remotely request their status. They can check the temperature, ensure that doors are locked/unlocked, verify that an appliance is on/off, and more. The 738Z makes it possible to take home control to the next level. • Turn on/off appliances and most electrically powered devices 67 FAX: 800.743.5724 CUSTOMER SERVICE: 866.266.2826 68 HOME CONTROL VIRTUAL KEYPAD™ APP The Virtual Keypad allows users to individually control Z-Wave devices, as well as devices in a group that has been programmed as ‘Favorites.’ The Favorites feature lets them program multiple devices to all respond to a single command. For example, the Favorite called “Movie Night” could lock the exterior doors and close the garage door, then adjust the temperature and dim the lights in the family room to the desired level. Favorites can also be placed in a panel schedule. With Favorite Actions, panels can be programmed to trigger ouputs upon arming and disarming events. The Rooms feature lets users quickly SIMPLE TO INSTALL AND PROGRAM Connect the 738Z to the keypad bus of the XT30/XT50 Series™ and XR150 | XR550 Series or to the programming header of an XTL™ Series Security System. Adding devices to the home control network is as simple as plugging in the module, and then plugging a device into the module. Programming the system to recognize the new device requires only a few button presses TEMPERATURE CONTROL Users have remote control over their thermostat. In addition to by-degree temperature control, they can also select Heat, Cool, Auto, Fan or Off. Z-Wave light control lamp module and dimmer enables on/off and dimming for incandescent lamps. CUSTOMERS CONNECT WITH Z-WAVE VIA MYACCESS™ AND VIRTUAL KEYPAD™ APP Appliance Module enables wireless control of on/off for std incandescent lamps, fluorescents, and small appliances. MYACCESS™ DOOR CONTROL By replacing standard mechanical locks with Z-Wave capable door locks, users have ability to remotely lock or unlock their doors, and to remotely check the lock status. The panel can be programmed to change the lock status based on the alarm system. For example, when a residential system is set to ARM Away, the panel will arm and can also direct the connected locks to lock Kwikset Z-Wave Door Deadbolt VIRTUAL KEYPAD™ Polished Brass Z-Wave Thermostat LIGHTING AND APPLIANCE CONTROL and easily create photo control panels for Z-Wave devices in rooms or areas. After taking a photo of the room or area with their smart phone or tablet, they create “hotspots” on the photo that correspond to one or more of the Z-Wave devices available. Then they can select that room from the app screen and touch any hotspot to access the controls for that device. Take total control of incandescent, fluorescent and compact fluorescent lighting with the 738Z and any of the wide variety of third-party control modules. Users can select plug-in modules or in-wall switches/dimmers. Venetian Bronze MYVIRTUALKEYPAD.COM Users can access their security system via internet connection on a tablet or computer and control their Z-Wave devices. Customers log into myvirtualkeypad.com with their login and system user code. With Z-Wave added to the system, the user has the ability to control connected lights, thermostats, exterior door locks, and other Z-Wave enabled devices. Their laptop can become a wireless control center 69 Satin Nickel SYSTEM SPECIFICATIONS ORDERING INFORMATION 738Z Z-Wave Interface Module 738Z Operating Voltage 8.0 to 14 VDC Current Draw 35mA Dimensions 4.5” W x 2.75” H x 1.75” D Z-Wave Light Control and appliance Module Dimensions 4” W x 2.375” H x 1.5” D Z-Wave Light Control Module with Dimmer Dimensions Z-Wave Thermostat Z-Wave Light Control Plug-In Module Plug the module into the outlet and the lamp into the module. Once connected and programmed, lights can simply be turned ON or OFF, or adjusted to any desired brightness in increments of 10%, from 10% to 100%. FAX: 800.743.5724 Dimensions Power Z-Wave Door Deadbolt Dimensions 4” W x 2.375” H x 1.5” D 5.7” W x 4.0” H x 1.2” D 24VAC from system 3.5” W x 5.5” H ORDERING SECTION Select from many third-party Z-Wave control modules or simplify ordering by choosing any of the modules available through DMP. Z-Wave Module 738Z Z-WAVE MODULE ACCESSORIES Z-45602 Z-45603 Z-45740 Z-45741 Z-45742 Z-99100-004 Z-99100-005 Z-99100-006 Z-99100-STAND Z-GD00Z-4 Z-LB60Z-1 Z-5010T Z-Wave Light Control Module with Dimmer Z-Wave Light Control and Appliance Module Z-Wave In-Wall Toggle Style On/Off Relay Switch Z-Wave Toggle Style Auxilary Switch Z-Wave In-Wall Dimmer Switch Z-Wave Door Deadbolt, Polished Brass Z-Wave Door Deadbolt, Satin Nickel Z-Wave Door Deadbolt, Venetian Bronze Demo Deadbolt Desk Stand Z-Wave Garage Door Controller Z-Wave LED Light Bulb Z-Wave Thermostat COMPATIBILITY XT, XTL and and XR150 | XR550 Series Panels CUSTOMER SERVICE: 866.266.2826 70 CAME AS VIDEO PRODUCTS CAMERA OPTIONS A WATCHFUL EYE FOR YOUR CUSTOMER’S SYSTEM RECORDER OPTIONS Select from a range of wireless IP cameras to meet the needs of each installation. Cameras are available in a variety of models including cube, dome, and other designs. 1 megapixel resolution. All cameras include infrared options and LED illumination for operation in low/no ambient light. Choose a camera with a motorized pan/tilt/rotation ability to completely survey the premises. Additional options include: • PIR motion sensor to trigger recording when motion is sensed IMAGE CAPTURE OPTIONS Users have the option not only to view the cameras attached to their system, but also to record video to document activity at their premises via the Virtual Keypad App or myvirtualkeypad.com. When using cameras equipped with PIR sensors, the system can be programmed to automatically record video clips when motion is detected. The user can opt to receive an email with the video clip any time a recording is made or download a clip to their smartphone. INDOOR/OUTDOOR BULLET CAMERA • Dimensions: 3.0” H X 2.4” W X 5.5” D • 1.3 megapixel resolution with IR LEDs for no/low light imaging at up to 30m Video cameras connected to residential and commercial security systems give users a powerful security tool. With cameras businesses and homeowners can check in on their premises at any time, as well as be prompted to determine the situation upon an alarm in the event of an intrusion. Central station operators can also assess the premises upon an alarm as live video and recorded clips are available immediately at the central station. V-4010B-1 SYSTEM FEATURES • Users can select any of the cameras remotely to view or capture video via their app or myvirtualkeypad.com • Wireless cameras can be quickly repositioned by the end user as needed Video capability is a much-desired, value-added capability for your customers’ systems. DMP forward/backward compatibility ensures that you can easily add cameras to existing systems as well as including them in new systems. COMPATIBILITY Standalone - Use with any DMP Control Panel or any other Control Panel when a DMP CellComSL™ or iComSL™ is installed. For use with Virtual Keypad App or myvirtualkeypad.com INDOOR CUBE PIR CAMERA • PoE - Power-over-Ethernet - when using a PoE switch for easy installation and reliability • 1.3 megapixel resolution with IR LEDs for no/low light imaging at up to 30m • Allows residential users to remotely look in on children or seniors • Dimensions: 5.2” H X 2.8” W X 3.6” D • Dimensions: 1.8" H x 12.4" W x 9.5" D • 1.3 megapixel resolution with PIR detection and IR LEDs for no/low light imaging at up to 10m • Full channel at 720P resolution realtime recording • Cloud storage of clips for easy off-site archiving • Video Verification available via Virtual Keypad App or the Central Station • Use exisiting analog or IP cameras • 720 HD 1 MegaPixel image quality V-4020C-1 HD IP MOTORIZED INDOOR CAMERA • Dimensions: 5.51" H x 4.49" W 8 CHANNEL NVR • Dimensions: 6.2” H X 3.4” W X 3.4” D • Built-in Wi-Fi router • Connect up to 8 IP cameras • On-board storage • 1.0 megapixel resolution with PIR detection and IR LEDs for no/low light imaging at up to 10m V-4408D V-4050D-1 WIRELESS ACCESS POINT (V-IP1006RR) V-4030PT-1 FAX: 800.743.5724 • Supports both HD-TVI and analog cameras with adaptive access • Motorized pan/tilt rotation • Allows commercial users to observe employee activities, monitor certain areas or entrances • Download clips to smartphone to quickly send to interested persons 71 4 CHANNEL DVR V-4404A • Dimensions: 4.4” Dia X 3.2” H • Initiate video recording via motion detection or from your App ADD-ON SALE DMP Virtual Keypad™ App users will receive real-time alarm notification on their mobile device that includes zone information. Users can immediately cancel or verify the alarm from the same app screen which includes live – camera views from the premises or pre-alarm & post-alarm recorded clips. INDOOR/OUTDOOR FIXED DOME INFRARED CAMERA • Install cameras wired IP or on a Wi-Fi network Record and access video images using existing analog cameras through the analog converter, or use existing IP cameras through the NVR. • Dimensions: 1.4” H X 7.1” W X 4.9” D CUSTOMER SERVICE: 866.266.2826 72 SOFTWA E GRAPHICAL SITE MAPS ENTRÉ TAKE TOTAL CONTROL OF YOUR INTRUSION AND ACCESS MANAGEMENT ENTRÉ SPEC With DMP Entré, XR Series Panel users can manage both intrusion and access control in one easy-to-use software application. System managers can now have fast, simple point-and-click control over every aspect of their security system. • Intuitive graphical user interface for system monitoring and control • All security management activities combined in a single, high-functioning platform • Three system size options, with one suitable for almost every facility or organization • Network system enables monitoring and control of facilities anywhere, from anywhere • Web or Standard user clients or both available ENTRÉ – ACCESS & SECURITY MANAGEMENT SOFTWARE SYSTEM FEATURES AES ENCRYPTION POWERFUL SEARCH Load an unlimited number of graphical Entré Enterprise supports the XR500E Industry standard SQL database can be images of your protected facilities in a variety and XR550E Series panels AES (Advanced quickly and easily searched to identify any of file formats. Once loaded, plot your alarm Encryption Standard) strong data security desired device or user which is compatible devices on the graphics using drag-andfor sensitive personnel and facility data. with nearly any database. drop selections from a hierarchical list of SINGLE-SYSTEM CONTROL hardware. Identify the areas on your site HIGHLY CUSTOMIZABLE Take advantage of the extensive As a network solution, you can manage maps, defining them by Classification, customization capabilities to create a system installations and users from anywhere. Entrances, Zones, and Partitions. that exactly matches your needs. Define A single, unified database means there’s what events are considered “alarms,” and one badge, one face or one fingerprint, With your site maps established, you have what response is required from the system worldwide. The easy-to-use interface total picture-based monitoring and control of operator. Tailor your user data with the 20 makes for simple system configuration your system. From facility-wide views, click available user-defined fields. and user rights management. to zoom in on any area of the facility and view the real-time status of any device. Point and HIERARCHICAL VIEWS AUTOMATION MODULE click on a device for more information or to Select from four different system views, Advanced users have the power to control and change its operating parameters. with the ability to have multiple views open create automated system actions. Define simultaneously. Select the graphical Map automatic responses to any system alarm USER MANAGEMENT view, tabular Event view, or hierarchical or events. These include generating a Avoid the need to re-enter user data Tree view. In any view, click on a device report, generating an alert email, or sending by importing it into Entré from existing or alert to access additional information commands to selected devices. Create systems via standard comma-separated and process the event. In text-based views, scheduled system actions to run once at value (CSV) format files. Easily add new simple drill downs allow fast navigation a specified time and date, or scheduled users, capture and edit their photo for to the desired item. For example, when events that repeat at your defined time and badges or visual verification, all within searching Protected Locations, start at the date intervals. System automation enables the application. top-level of Region and click down through you to configure unattended activities, Campus, Building, Floor, Area, and Subfreeing system managers from many User fields are fully customizable. Assign Area to view the desired location. routine responsibilities. specific rights or events by user or by group. Create effective/expiration time for users, limiting access to only certain times of the day, only certain days, or for only a defined period of time. . Site Map Screen Shot OPTIONAL SYSTEM MODULES FEATURES • Packages available: Entré Lite™: 16 doors included, up to four XR Series panels, personnel management, full reports, and event management Entré Business™: The same features as Entré Lite. Expandable to 96 doors maximum and up to 24 XR Series panels Entré Enterprise™: The same features as Entré Business with 96 doors included. Expandable to unlimited number of doors, users and XR Series panels* • Point-and-click control of alarms and devices • Modular design enables customization, with optional modules for added features • Available in French, Spanish, or English, with dual-language operation mode • Full reporting with the ability to produce reports in a variety of file types • Image management of users and event photos • Assign user access by group, facility or other parameters • Event Photos • Drop down lists for devices, user data and other information facilitate fast and accurate searches Tree View Screen Shot • DVR integration • Simple user management, with the ability to import users from existing databases • XR150|XR550 supports 8 schedules per area, door and output Site Map Screen Shot with Alarm • Custom badge builder and video badging One XR150N Control Panel will support up to 8 Doors of Access. One XR550N Control Panel will support up to 16 Doors of Access. • View system status in one of a variety of views for simplified alarm monitoring management • Customizable reports for added flexibility 73 FAX: 800.743.5724 CUSTOMER SERVICE: 866.266.2826 74 SOFTWA E SIGNATURE CAPTURE DVR/NVR When used with a signature capture device, Entré provides the ability to capture employee or visitor signatures and store the images. BADGE IMAGE CAPTURE Transfer pictures of users from a digital camera directly onto a badge. Select a TWAIN source to capture the image to allow up to date images on employee badges. BADGE DESIGNER Create one or more badge designs, customizing badges by facility, user level, or other parameters. When badging employees or visitors, select the desired badge template from your library. The template automatically populates with the appropriate data, ready for printing. Optional Modules DOOR MODULES Allows you to add 4, 16, 32, 64, or 128 more doors to Entré Business or Enterprise systems. DATABASE PARTITIONING Quickly connect to a DVR to review video based on a received alarm from a control panel. Connect to the DVR from a graphical map of the area to review activity. The following drivers are supported: • Verint NetDVR I, firmware 6.47.x or higher NetDVR II, firmware 8.7.x or higher EdgeVR, all firmware versions • 3VR E-Series P-Series S-Series ServerClass With Entré, all system information is contained in a single unified database allowing system managers who want to limit user access to only certain areas of the database to partition the information. Organize your data into separate collections of data by physical area, hardware types, events, or other parameters. A valuable benefit for landlords who want to provide each tenant with control of only their part of the building. DUAL-LANGUAGE Entré supports English and Spanish. Enabling dual-languages allows the operator to select a language during their login process. • March Networks™ 3204 Digital Video Recorder (3000 Series) 4000 C NVR (4000 C Series) • Dedicated Micros All NetVU compatible series 2 and 3 DVRs EVENT PHOTOS MODULE The Event Photos module displays real-time events along with personnel photos. ORDERING INFORMATION OPTIONAL MODULES Note: Certification and Dealer Agreement is required to purchase Entré ENTRE LITE • 1-4 XR* Series Panels • Includes 16 Doors of Access Maximum • 10,000 Users Maximum ENTRE BUS • 1-24 XR* Series panels • Includes 16 Doors of Access • Expandable to 96 Doors of Access Maximum ENTRE-4DR ENTRE-16DR ENTRE-32DR ENTRE-64DR ENTRE-128DR ENTRE-BADGE ENTRE-DVR ENTRE-LANG ENTRE-PART ENTRE-PHOTO ENTRE-STD ENTRE-WEB Additional 4-Doors Additional 16-Doors Additional 32-Doors Additional 64-Doors Additional 128-Doors Custom Badge Designer DVR/NVR Module Multiple Language module Database Partitioning Event Photos Standard Client Web Client • 10,000 Users per panel • Expandable to Unlimited number of Users ENTRE ENT • Unlimited XR* Series panels • Includes 96 Doors of Access • Expandable to Unlimited Doors of Access* • 10,000 Users per panel • Expandable to Unlimited number of Users in database ALARM GRAPHICS The graphical representation of events and alarms gives you at-a-glance feedback of system status. System maps are linked from level to level, allowing you to drill down from a macro view to a specific room or area. View alarm status at every level of zoom. User-defined layers representing different alarm types allow you to customize the graphical interface to meet your needs. Click on the alarm display icon to acknowledge an alarm or request additional information. One XR150N Control Panel will support up to 8 Doors of Access. One XR550N Control Panel will support up to 16 Doors of Access. SYSTEM REQUIREMENTS OPERATING SYSTEM COMPATIBILITY • 800 x 600 or higher monitor resolution • Windows 7 • CD-ROM drive • Windows Vista • One NIC Card • Windows XP • 2 GB RAM • Windows Server 2008/2008 R2 • PC 3.2 GHz Pentium Processor • JRE 1.6 • Linux 2.0 GHz Intel Processor or higher • MySQL (Required for Linux) • Apache Tomcat Server 5.5-6.0 (Required for web clients) PANEL COMPATIBILITY The Entré software is compatible with the following DMP XR Series Panels: XR150 | XR550 Series Panels SOFTWARE LICENSE One license per workstation (Standard client) One license per concurrent seat (Web client) Badge Designer 75 FAX: 800.743.5724 CUSTOMER SERVICE: 866.266.2826 76 ENTRÉ SYSTEM DESIGN Student Center XR550N Library ENTRÉ SERVER (Entré Lite, Entré Business, Entré Enterprise) Administration XR550N XR550N Bookstore XR550N Dormitory Web Client XR550N Proximity Reader ENTRÉ WORK STATIONS Map View CENTRAL STATION AUTOMATION WORK STATION ENTRÉ BADGING WORK STATION 77 FAX: 800.743.5724 CUSTOMER SERVICE: 866.266.2826 78 CENT AL STATION RECEIVER COMMUNICATIONS SCS-1R The SCS-1R allows digital data networks and digital dialer operation on one receiver. Expandable to eight line cards, each card can be programmed for digital network or dialer operation. NOW WITH CONTACT ID! INCREASE REVENUES A ROCK-SOLID FOUNDATION FOR CENTRAL STATION PROFITS SCS-1R SPEC To realize the full benefits of DMP alarm panels, you will want to use a DMP Receiver. • Facilitates panel trapping for unattended area code changes • UL approved for digital networking or dialer operation • Supports Caller ID and Contact ID (CID) using the SCS-104 line card NIST VALIDATED AND UL LISTED FOR ENCRYPTION • Boost income with revenue-producing features built into every DMP panel • Automatic daylight savings time update of all DMP panels • Unattended upload/download of all DMP panels network or dialer • No maintaining automation tables - full data through to automation SCS-1R is designed to meet the growing demand for network monitoring with flexible, expandable solutions. The SCS-1R records all openings/closings, zone bypasses, door access, code changes, and schedule changes. Reports do not require operator acknowledgment, which cuts labor costs and offers more billable monitoring services. PROFITABLE NETWORK MONITORING Exclusive DMP technology provides worldwide supervision, allowing you to increase your RMR, expand your market, and reduce your expenses. The SCS-1R is UL listed for communication via public network or private intranet. Alarm monitoring can simply travel on existing network infrastructures adding value for the subscriber without incurring additional wiring costs. 32-CHARACTER LCD DISPLAY AND KEYPAD The SCS-1R contains a built-in 32-Character English LCD display which eliminates alarm signal decoding, reduces operator errors, and allows operators to respond more quickly to alarm reports in the case of automation failure. The same English text messages and zone names, which are normally sent to the automation computer, are also displayed on the LCD display and identify the exact nature of the problem. REPORTING CAPABILITIES SCS-1R NETWORK ENABLED RECEIVER SYSTEM FEATURES • Up to eight line cards • Configure up to 32 digital dialer lines and eight network connections • 65,535 digital dialer accounts • 3,200 data network accounts • 5,000 event memory • 19” rack mountable • Line card slots can be configured for digital dialer and/or Network operation • Factory configured and ready for Ethernet communication • UL Standard Line or Encrypted Line Network Monitoring 79 FAX: 800.743.5724 • Host Automation over Serial or Network • Supports DMP Cellular Communicators with no additional line cards to purchase • Includes AES Encryption • UL 864 Commercial Fire Monitoring • Membrane keyboard and 32-character LCD display • Full English readout on all alarm messages • Built-in processor watchdog and internal voltage monitors • Separate alarm message printer available • Optional output to automation computer • Browser Programming from any computer • • • • • Alarms, troubles, and restorals Opening and closing reports Bypass and reset reports Supervisory reports Door access reports • Permanent/Temporary schedule changes • Addition and deletion of code numbers • All messages provide the account number, time, and date of occurrence. SCS-1R SYSTEM LISTINGS AND APPROVALS 19" W x 8.75" H x 12"D 19" rack mountable Refer to the SCS-1R Installation and Operator’s Guide (LT-1037) and specific compliance listings for installation and programming requirements necessary to meet a particular approval. ACCESSORIES SCS-1R Spares Remote Link Alarm Monitoring Command Center Advanced Reports Account Groups Link Server Entré CS The SCS-120 Multibus Power Supply Card provides power to the processor card through the multibus backplane. The card also monitors the condition of the processor card, the voltage output of the modem power supply card, and its own internal voltages. The Model SCS-1R Security Control Receiver includes all of the system components required to provide four digital dialer lines and one line capable of SCS-130 TRANSFORMER CARD The SCS-130 Transformer Card provides receiving data over a network. The SCS-1R power to the modem power supply card system includes: and the multibus power supply card. • SCS-RACK with multibus cage, fan, and membrane keypad with LCD display SCS-150 PROCESSOR CARD The main system processor that controls • SCS-104 Line Card the line cards, LCD display, and the • SCS-110 Modem Supply Card printer. The processor card contains the software for system operation, the • SCS-120 Multibus Power Supply Card EEPROM memory of system configuration, • SCS-130 Transformer Card and performs all time-keeping functions. Programming for this card is done easily • SCS-150 Processor Card via the front panel display keypad, or • SCS-203 Convenience Panel via the network using Internet browser. Provides the fast transmission speeds • SCS-208 Power Cord and high data integrity of the Serial 3 communications format, with a 5000SCS-104 LINE CARD event, battery-backed buffer. Enhanced The SCS-104 provides four digital dialer reliability, and the very low power (DD) lines and a network connection consumption give longer life when using for communication to DMP panels. Each backup power. Future SCS-150 software card includes one shielded eight-pin updates can be made via the SD card modular connector (J1) for the digital memory port. No eproms to change. data network connection, and one RJ61X connection for four phone lines. This SCS-203 CONVENIENCE PANEL allows the SCS‑1R Receiver to accept The panel provides cabling for three alarm and system messages over dialer RS-232 ports. and network from DMP panels. The SCS-104 receives and captures Caller SCS-CTM SOFTWARE ID information, and supports CID format. SCS-CTM Check-in Table Manager software ensures no panel supervision SCS-110 MODEM POWER check-ins are lost when an SCS-104 SUPPLY CARD line card is replaced. Additionally, use The SCS-110 Modem Power Supply Card the SCS-CTM Check-in Table Manager provides power to a maximum of eight line to mirror a primary receiver or SCS-104 cards through the modem rack backplane line card for use on a secondary receiver connectors. No additional cabling is or SCS-104. required. SPECIFICATIONS Dimensions SCS-120 MULTIBUS POWER SUPPLY CARD Spare Board Kit Remote Programming Software Alarm Monitoring Software Visual Command and Control Software Reporting Software Account Grouping Software Client Server Software Central Station Access Management Software California State Fire Marshal (CSFM) FCC Part 15 FCC Part 68 New York FDNY NIST Validated Certificate #2350 Underwriters Laboratories (UL) Listed Underwriters Laboratories Canada (ULC) Listed For additional information, access www.dmp.com and select Compliance. CUSTOMER SERVICE: 866.266.2826 80 CENT AL STATION VIRTUALLY BETTER SCS-VR UL APPROVED FOR CENTRAL STATIONS ADVANCED RECEIVER FUNCTIONALITY WITH NO HARDWARE SCS-VR SPEC For the first time you can rely on a software-only network service operating as a virtual receiver for IP and Cellular alarm communications. Equip your Central Station with a high-functioning, highly reliable receiver with no proprietary hardware. • Manages all network and cellular alarm signals, supervision, and substitution messages • Capacity to monitor up to 20,000 panels • Can be used as primary receiver(s) or backup to existing hardware receivers • Advanced diagnostics ensures more reliable service and faster troubleshooting • Full logging of diagnostic data • UL Approved for Commercial Burglary and Commercial Fire and CSFM for Central Stations The Virtual Receiver delivers all of the unique DMP advantages, including extensive redundancy, and reporting is scalable from one to thousands of network control panels. SCS-VR VIRTUAL NETWORK RECEIVER As a virtual receiver, you avoid all hardware-related costs. There is no additional rack space required and no power requirement beyond your standard networking equipment. Install the software on any UL-listed server, where the SCS-VR can act as the primary receiver or back-up to meet UL Central Station classification. Regular updates are automatic and totally transparent. Choose the optional network upgrade sharing service to automatically distribute updates to all nodes attached to the current database. DATABASE DRIVEN The SCS-VR supports the Microsoft SQL Server 2005 and SQL Server 2008, with the ability to run on more than one server from the same database. SCALEABLE FOR GROWTH Select the capacity needed to meet the needs of your Central Station, from 500 to 20,000 panels. Select the SCS-VR model needed for your current needs. At any time you can purchase a license for additional capacity to quickly expand your monitoring capacity, with no additional hardware. PROFITABLE NETWORK MONITORING Exclusive DMP technology provides worldwide supervision, allowing you to increase your RMR, expand your market, and reduce your expenses. Alarm monitoring can simply travel on existing network infrastructures, adding value for the subscriber without incurring additional wiring costs. CREATE GROUPS SERVER AND This new feature allows you to “divide” PATH REDUNDANCY a single receiver into multiple receivers The virtual receiver can run on a single whether on a single or on multiple servers, server or multiple servers from the same each with its own unique programming. database, ensuring data redundancy. Each Define different dispatch or message server that is part of the system serves as handling rules for each group on a receiver. the automatic backup to the other system. Each group configuration can be saved Since the receivers can accept messages with a unique name. The Group capability via a primary and secondary path (network gives you greater flexibility and enables and cellular), you also have redundant paths you to get the maximum performance from ensuring reliability for reporting information. each SCS-VR. Five groups come standard with each SCS-VR package. If the receiver operates on more than one server from the same database, the receiver MORE POWERFUL DIAGNOSTICS can be set to work with load balancing Be assured that your panels are functioning operation ensuring that receiver traffic is at peak performance with the expanded equally dispersed amongst the receivers. SCS-VR diagnostics screens and full logging of information, including: REPORTING CAPABILITIES • Panels currently in substitution failure • Alarms, troubles and restorals • Panels not currently checking-in • Opening and closing reports • Average bandwidth per panel • Bypass and reset reports • Recent bandwidth per panel • Supervisory reports • Average bandwidth per group of panels • Door access reports • Show panels that use excessive bandwidth • Permanent/Temporary schedule changes • Time of last check-in message received per panel • Time of last message received per panel, plus the text of the message • Code number additions/deletions • All messages provide the account number, me, and date of occurrence • IP address of each panel • Show which panels use encryption and which do not • Show when the IP address of a panel has changed SYSTEM FEATURES • Replaces need for receiver hardware when using DMP network alarm messaging • Increased traffic capacity compared to SCS-1R • Can run on a single server or across multiple servers • Multiple server configuration works with load balancing to avoid server overloads • Improved panel-to-receiver path redundancy • Multiple groups • Accepts network or cell messages from panel (no dial-up) • Unlimited number of groups (5 included) • Inbound and outbound TCP network connections to various automation software • Accepts Serial 3 Full English text transmission from DMP panels • Extensive diagnostics • NIST validated AES encryption enables use in the highest security applications, including government and financial facilities • Automatic time updates via network • Reduces space, power, cooling, and maintenance requirements • Uses Microsoft® SQL Server® database with Windows® SYSTEM REQUIREMENTS • • • • • 2.8 GHz Intel Pentium 4 Processor CPU 2 GB RAM 160 GB Hard Drive 1024 x 768 or higher monitor resolution CD-ROM drive OPERATING SYSTEM COMPATIBILITY • • • • • Windows Server 2003 Windows Server 2008 (Required for UL) Windows Vista Windows XP Windows 7 SOFTWARE COMPATIBILITY • Microsoft SQL Server 2005 or higher (2008 required for UL) • Microsoft SQL Express 2008 81 FAX: 800.743.5724 LISTINGS AND APPROVALS NIST Validation: 1440, 3027 Underwriters Laboratories (UL) Listed ANSI/UL 1076 Proprietary Burglar ANSI/UL 1610 Central Station Burg Alarm Units Accessory ANSI/UL 864 Fire Protective Signaling (Version 1.3.6 or higher) OPERATING INFORMATION • • • • • • SCS-VR 500 SCS-VR 2500 SCS-VR 5000 SCS-VR 10000 SCS-VR 20000 SCS-VR 5GRP/UPG 500 panels 2500 panels 5000 panels 10000 panels 20000 panels 5 Group Upgrade Note: Support for more than 20,000 panels available upon request CUSTOMER SERVICE: 866.266.2826 82 CONTROL PANELS XTLC The XTLC Wireless Control Panel is our smallest panel ever; measuring 3.75 X 5.5 inches. It comes packed with almost all of the popular security features found in our full-sized DMP panels. Supports 28 wireless zones, and 8 wireless key fobs or outputs. On-board CDMA cellular communications allows MyAccess messaging features with any cell phone Color: White ORDER: XTLN XTLN The XTLN Wireless Control Panel is our smallest panel ever; measuring 3.75 X 5.5 inches. The XTLN comes packed with almost all of the popular security features found in our full-sized DMP panels. Supports 28 wireless zones, and 8 wireless key fobs or outputs. The on-board network communication allows for the Virtual Keypad™ App to be used to access panel functions via an internet connection. XTLN-WIFI The XTLN-WiFi Wireless Control Panel is our smallest panel ever; measuring 3.75 x 5.5 inches. The XTLN-WiFi comes packed with almost all of the popular features found in our full-sized DMP panels. Supports 28 wireless zones, and 8 wireless key fobs or outputs. The on-board WiFi communication allows for the Virtual Keypad™ App to be used to access panel functions via an internet connection. 372-500 B PLUG-IN DC POWER SUPPLY Color: White ORDER: XTLN-WIFI Color: White ORDER: 372-500-B A 12 VDC DC Plug-in Power Supply for XTLC. For use with: XTLN & XTLN-WIFI. 372-500 W PLUG-IN DC POWER SUPPLY ORDER: 372-500-W A 12 VDC DC Plug-in Power Supply for XTLC. For use with: XTLC. XTL DEMO SYSTEM XTL Demo case includes: • 1106 Door/Window Transmitter • 1127W Wireless PIR • 1135 Wireless Siren • 1145 Wireless 4-button Key Fob ORDER: XTLC ORDER: XTLC DEMO XTLN DEMO • 9063 Keypad • Extension Cord • XTLC Panel NOTE: Products must be removed from original packaging and placed into Demo case. XT30 SERIES The XT30 Burglary/Fire/Door Access Panel is ideal for both residential and small commercial applications. It supports 10 on-board and 28 additional wired zones and one two-wire smoke detector zone. XT30 is compatible with 1100D Wireless Series receivers and devices. Customize this powerful panel to include any or all communication options: Network and/or Dialer. This panel also supports MyAccess™ & DMP App, 30 user codes, and daily opening and closing schedules. ORDER: XT30DM-G XT30DNM-G XT30DNS-G XT30DS-G XT30M-G XT30NM-G XT30NS-G XT30S-G PCB OPTIONS ALSO AVAILABLE XT50 SERIES The innovative XT50 Burglary/Fire/Door Access Panel is ideal for both residential and small commercial applications. It supports 10 on-board zones plus 28 wired or 48 wireless for up to 58 total zones and one two-wire smoke detector zone. Customize this powerful panel to include any or all communication options: Network and/or Dialer. Includes an on-board 1100D Series Wireless Receiver. Also supports MyAccess™ & DMP App, 99 user codes, and daily opening and closing schedules. 83 FAX: 800.743.5724 CUSTOMER SERVICE: 866.266.2826 ORDER: XT50DM-G XT50DNM-G XT50DNS-G XT50DS-G XT50 DEMO XT50S-G PCB OPTIONS ALSO AVAILABLE 84 ENCLOSURES ENCLOSURES CONT. CONTROL PANELS XR150 SERIES The XR150 features 142 inputs, 8 keypads = 32 zones, 1 built-in LX Bus (100 Zones), and 10,000 user codes with 99 profiles. It provides ease of programming, dialer & network connectivity, systems integration, flash updates plus intuitive operation designed with end-users in mind. Includes 50VA transformer. Compatible with all DMP 1100 Series Wireless and Keypads including the 7800 series. Supports the DMP App. XR550 SERIES The XR550 features 574 inputs, 10 On-Board Zones, 16 keypads = 64 zones, 5 built-in LX Bus (100 Zones per LX), and 10,000 user codes with 99 profiles. It provides ease of programming, dialer & network connectivity, systems integration, flash updates plus intuitive operation designed with end-users in mind. Includes 50VA transformer. Compatible with all DMP 1100X Series Wireless and Keypads including the 7800 Series. Supports the DMP App. XR150FC FIRE CONTROL PANEL The XR150 features 142 inputs, 8 keypads = 32 zones, 1 built-in LX-Bus (100 Zones), 10,000 user codes with 99 profiles and a built in LCD Fire Command Center keyboard with membrane keyswitch. It provides ease of programming, systems integration, flash updates plus intuitive operation designed with end-users in mind. Includes built-in 56 VA Transformer. XR550FC FIRE CONTROL PANEL The XR550 features 574 inputs, 10 On-Board Zones, 16 keypads = 64 zones, 5 built-in LX Bus (100 Zones per LX), 10,000 user codes with 99 profiles and a built in LCD Fire Command Center keyboard with membrane keyswitch. It provides ease of programming, systems integration, flash updates plus intuitive operation designed with end-users in mind. Includes built-in 56 VA Transformer. ORDER: XR150DL-G XR150DL-R XR150DNL-G XR150DNPCB XR150DPCB XR150L-G XR150NL-G XR150DNL-R XR150NPCB XR150PCB ORDER: XR550DEL-G XR550DEPCB XR550DL-G XR550DL-R XR550DNL-G XR550DNL-R XR550DNPCB XR550DPCB ORDER: XR150DNFC-R XR150DFC-R Steel enclosure with dual 3/4" or 1/2" knockouts, module mounting holes, and room for two 7.7 Ah batteries. Dimensions: 12.5" W x 9.5" H x 2.85" D 341 PANEL ENCLOSURE Gray steel kiosk size enclosure with dual 3/4" or 1/2" knockouts and module mounting holes. Dimensions: 12.75" W x 6.55" H x 2.9" D 341B BATTERY BRACKET WITH 318T BATTERY HARNESS The 341B Battery Bracket mounts inside the lid of the 341 Kiosk enclosure providing two Model 364 1.3Ah batteries for battery backup. A 318T Dual Battery Harness is included for battery connection to the panel. 85 FAX: 800.743.5724 ORDER: 349-G Standard panel enclosure with dual size knockouts, lock and key, and standard 3-hole pattern for module mounting. Room for two 7.7 Ah batteries. Dimensions: 12.5" W x 11.5" H x 3.5" D For use with: XT Series Panels. 349 GRADE A PANEL ENCLOSURE ORDER: 349A-G Standard panel enclosure with dual size knockouts, lock and key, and standard 3-hole pattern for module mounting. Dimensions: 13.5" W x 11.66" H x 3.55" D For use with: XT Series Panels. 349S ENCLOSURE SHELF ORDER: 349S-G Standard panel enclosure shelf. Room for two extra 7.7 Ah batteries. Dimensions: 12.5" W x 9.5" H x 3.75" D 350A GRADE A PANEL ENCLOSURE The 350A is a large, Grade A, attack-resistant enclosure that has a heavy 16-gauge rolled steel door, tamper switches, and an inside mounting bracket for a wire-in transformer. Models 350B, 350C, and 350D can be added to provide for accessory module installations and additional conduit positions. Dimensions: 17.5" W x 13.5" H x 3.75" D ORDER: XR550DNFC-R XR550DFC-R ENCLOSURES 340 PANEL ENCLOSURE 349 PANEL ENCLOSURE ORDER: 340-G 340-R For use with: XT Series, and 714-8/16 and 715-8/16 Zone Expansion Modules. ORDER: 341-G For use with: XT Series and XR Series Panels and 323/324P Wire-in Transformer. 350B SLIDE-IN BRACKET For use with: 349 Panel Enclosure. ORDER: 350A-G For use with: XR Series Panels. ORDER: 350B The 350B is a slide-in bracket that provides a standard 3-hole pattern for auxiliary module installation. Dimensions: 3" W x 3.4" H x .2" D. For use with: 350 and 350A Enclosures. 350C CONDUIT BACKBOX ORDER: 350C-G The 350C is a conduit backbox that attaches to the rear of the enclosure to provide additional conduit positions. Dimensions: 17.1" W x 13.2" H x 1.5" D For use with: 350 and 350A Enclosures. 350D MOUNTING PLATE ORDER: 350D-92 Mounting plate that is easily installed in any enclosure to provide a standard 3-hole pattern for mounting DMP auxiliary modules. Dimensions: 5.5" W x 5" H x 1.775" D 350 LARGE PANEL ENCLOSURE Large enclosure holds three 7.7 Ah batteries or two 18.0 Ah batteries, one transformer and two standard 3-hole patterns for mounting modules. Dimensions: 17.5" W x 13.5" H x 3.5" D ORDER: 341B For use with: Any Enclosure. ORDER: 350-G 350-R For use with: XR Series Panels, and 323/324 Transformer. For use with: 341 Kiosk Enclosure CUSTOMER SERVICE: 866.266.2826 86 ENCLOSURES ENCLOSURES CONT. 350S ENCLOSURE SHELF ORDER: 350S-G Standard panel enclosure shelf. Room for two extra 7.7 Ah batteries. Dimensions: 16.88" W x 8.4" H x 3.1" D For use with: 350 Panel Enclosure. 351 UNIVERSAL MOUNTING PLATE ORDER: 351-G The Universal Mounting Plate is a mounting skirt that allows you to upgrade older DMP 1812 series control panels without removing the enclosure and conduit from the wall. It will also quickly and easily allow you to upgrade all Radionics enclosures to any DMP XR Series Panel. Dimensions: 10.5" W x 12.25" H x .77" D For use with: DMP 1812 Enclosures, and all Bosch Enclosures. 352S EXTRA LARGE BATTERY ENCLOSURE ORDER: 352S-G Extra Large enclosure with five adjustable shelves to hold batteries for standby power. Dimensions: 14.5"x 32"x 4" (lid adds 0.5" on each side) For use with: XR Series. 352X EXTRA LARGE ENCLOSURE ORDER: 352X-G Extra large enclosure with transformer and mounting plate to hold an XR Series panel, power supply, and one zone expander PCB. One battery shelf included. Dimensions: 14.5" x 32" x 4" (lid adds 0.5” on each side) For use with: XR Series. 353 STEEL ENCLOSURE ORDER: 353-G Gray steel enclosure for wire runs. Includes conduit accessories for connection to panel enclosure. Dimensions: 12” x 15" x 4" For use with: XR Series. 354A RETROFIT MOUNTING PLATE Gray retrofit mounting plate that installs in a 350 or 350A large enclosure and provides space for two zone expander PCBs. Dimensions: 12.5" x 11.7" 354 RETROFIT MOUNTING PLATE Gray retrofit mounting plate that installs in a 350 or 350A large enclosure and provides space for one zone expander PCB. Dimensions: 10.25" x 6" ES501 TRANSFORMER ENCLOSURE Low voltage plug-in transformer enclosure. Metal construction with hinged cover. Vented, for use with transformers over 20 VA. Dimensions: 4.625" x 5.75" x 2.5" ES502 TRANSFORMER ENCLOSURE Low voltage plug-in transformer enclosure. Metal construction with hinged cover. Vented, for use with transformers over 20 VA. Also used for physically protecting plug-in sure protectors. Dimensions: 4.25" x 5.625" x 3.75" 87 FAX: 800.743.5724 ORDER: 354A-G For use with: 350 Enclosures or other exisiting enclosure. ORDER: 354-G For use with: 350 Enclosures or other exisiting enclosure. ORDER: ES501 For use with: All popular transformers. ORDER: ES502 For use with: Transformers and surge protectors. CUSTOMER SERVICE: 866.266.2826 88 PACKAGES & KITS PACKAGES & KITS PACKAGES & KITS CONT. XT30 PANEL PACKAGES ORDER: XT30DS/7360-W XT30DS/7360-W/B XT30DS/7360-W/P Standard Panel Package includes XT30 panel in 340 Enclosure, 7360 Keypad, and 321 40 VA Plug-in Transformer. Basic Wireless Package includes XT30 panel in 340 Enclosure, 7360 Keypad, 321 40 VA Plug-in Transformer, 1100DI In-line Wireless Receiver, Two 1106 Wireless Universal Transmitters. Minimum order of 6. Price breaks on orders of 12, 24, 48, and 96. XT50 PANEL PACKAGES ORDER: XT50DS/7360-W XT50DS/7360-W/B XT50DS/7360-W/P Basic Wireless Package includes XT50 panel in 340 Enclosure, 7360 Keypad, 321 40 VA Plug-in Transformer, Two 1106 Wireless Universal Transmitters. Minimum order of 6. Price breaks on orders of 12, 24, 48, and 96. EXAMPLE ALTERNATES PANEL W = White I = Ivory* NETWORK 89 N = 10/100 Ethernet on-board KEYPAD 7360 = Icon LCD (default) 7363 = Icon LCD w/prox 7060/7160 = Thinline LCD 7063/7163 = Thinline LCD w/prox 7070/7170 = Thinline LCD w/4 zones 7060A = Aqualite LCD 7063A = Aqualite LCD w/prox 7070A = Aqualite LCD w/4 zones * Alternate color keypads only available for 7000 7872/7873 = Touchscreen w/prox Series 9060 = Thinline Wireless LCD 9063 = Thinline Wireless LCD w/prox XT30 XT50 06 07 27 29 KEYPAD COLOR - FAX: 800.743.5724 ORDER: PKG-XR150DF PKG-XR150DNF The Prox Patch is a small, adhesive credential that adheres to nearly anything that you carry with you all the time. Containing a standard HID proximity device, it allows you to arm/disarm your alarm system or gain access to any DMP Security Command System. (PKG of 10) = = = = 1326 PROXCARD II CARD 7060A 7070A w/zones K = Key Fob B = Basic P = Premium D = 1100D H = 1100DH (Wireless PKG only) 9060/9063 w/prox 9862 Impact resistant construction, standard key size, and consistent read capability make the ProxKey III an ideal choice for an unobtrusive access device. Can be installed on key ring for convenience. (PKG of 10 or 100) 1351 PROXPASS® (Wireless PKG only) 1106 (replaces 1145) 1107 (replaces all 1106) 1127W (replaces 1121) 1129 (replaces 1121) RECEIVER 7872/7873 Thin, durable credit card size, 26-bit proximity cards. Flexible enough to be carried in a wallet. Slot punched for use with a strap clip. Passive no-battery design allows an infinite number of reads. Card read is not affected by body shielding or by being next to metal keys. (PKG of 10 or 100) 1346 PROXKEY III ACCESS DEVICE / WIRELESS Panel package includes the XR550 panel in 350 Red Enclosure, a 630F-R Remote Annunciator, 866 Notification Module, 322 56VA Transformer, a 318 Battery Harness, and a 270 Network Transient Suppression Module. (PKG-XR550DNF Only) 1306 PROX PATCH® Upgrade on-board options to: Network (N) Dialer (D) Upgrade keypad to: 7363 w/prox 7060/7160 7063/7063A w/prox 7070/7170 w/zones Upgrade Basic or Premium Package 1100 Series Wireless Receiver to: 1100D 1100DH Upgrade Wireless: 1127W 1129 Upgrade enclosure to: 349 (Medium) / XR150 RED ENCLOSURE PACKAGE ORDER: PKG-XR550DF PKG-XR550DNF CREDENTIALS INCREASE THE VALUE OF YOUR STANDARD PACKAGE WITH THESE COST-EFFECTIVE UPGRADES S = 340 (Small) M = 349 (Medium) ORDER: PKG-XR550DFC PKG-XR550DNFC XR550 RED ENCLOSURE PACKAGE Premium Wireless Package includes XT50 panel in 340 Enclosure, 7360 Keypad, 321 40 VA Plug-in Transformer, Three 1106 Wireless Universal Transmitters, 1121 Wireless PIR, and 1145 Wireless Four-Button Key Fob. ENCLOSURE SIZE XR550 SERIES FIRE CONTROL PACKAGE Panel package includes the XR150 panel in 350 Red Enclosure, a 630F-R Remote Annunciator, 866 Notification Module, 322 56VA Transformer, a 318 Battery Harness, and a 270 Network Transient Suppression Module. (PKG-XR150DNF Only) Standard Panel Package includes XT50 panel in 340 Enclosure, 7360 Keypad, and 321 40 VA Plug-in Transformer. D = Digital Dialer (on-board) ORDER: PKG-XR150DFC PKG-XR150DNFC Panel package includes the XR150 panel in 350 Red Enclosure with built-in 630F-R Remote Annunciator in the door as well as a 56VA Transformer, 866 Notification Module, 318 Battery Harness, and a 270 Network Transient Suppression Module (PKG-XR150DNFC Only). Panel package includes the XR550 panel in 350 Red Enclosure with built-in 630F-R Remote Annunciator in the door as well as a 322 56VA Transformer, 866 Notification Module, 318 Battery Harness, and a 270 Network Transient Suppression Module (PKG-XR550DNFC Only). Premium Wireless Package includes XT30 panel in 340 Enclosure, 7360 Keypad, 321 40 VA Plug-in Transformer, 1100DI In-line Wireless Receiver, Three 1106 Wireless Universal Transmitters, 1121 Wireless PIR, and 1145 Wireless Four-Button Key Fob. DIALER XR150 SERIES FIRE CONTROL PACKAGE CELLULAR (Modules) 3C = 263C CDMA 3H = 263H HSPA+ Package notes: Price breaks in multiples of 6. Six minimum order.ALL Packages include the 321 (40VA) Transformer. ALL Package permutations may not be in stock and may require additional lead time. Please check with customer service or your Regional Manager for availability and lead times. All standard DMP Terms and Conditions apply. HID’s ProxPass® is an active tag specifically designed for vehicle access control. Providing convenient access control for parking and fleet management application, ProxPass is the ideal augmentation to an existing or new HID proximity installation. 2-5 year battery life. Dimensions 3.61" x 2.66" x 0.3" 1386 ISOPROX II CARD Extremely thin, durable, and the size of a credit card. Passive, no-battery design allows an infinite number of reads. Provided blank for customization or badging applications (PKG of 10) CUSTOMER SERVICE: 866.266.2826 ORDER: 1306P/10 For use with: All HID Readers, DMP keypads with proximity readers. ORDER: 1326/10 1326/100 For use with: All HID Readers, DMP keypads with proximity readers. ORDER: 1346P/10 1346P/100 For use with: All HID Readers, DMP keypads with proximity readers. ORDER: 1351 For use with: MX-5375 MaxiProx Reader. ORDER: 1386/10 For use with: All HID Readers, DMP keypads with proximity readers. 90 ACCESS CONTROL READERS MODULES & ACCESSORIES 1346 KEYRING Keyring for the 1346 ProxKey III Access Control keyfob. 1346 KEYFOB METAL RIM KEY TAG Keyring with metal rim key tag for the 1346 ProxKey III Access Control keyfob. 332 LANYARD 34" Breakaway nylon black lanyard with split ring. 333 TRANSIENT SUPPRESSOR Provides transient protection. ORDER: 1346-RING For use with: All HID Readers, DMP keypads with proximity readers. ORDER: 1346-TAG For use with: All HID Readers, DMP keypads with proximity readers. ORDER: 332 734 WIEGAND INTERFACE MODULE 734N NETWORK WIEGAND INTERFACE MODULE ORDER: 333 ORDER: 734 For use with: All DMP XT & XR Series Panels. Color: White ORDER: 734N The 734N Module provides codeless entry plus system arming and disarming using DMP access cards or credentials; or customizable for other credentials. Provides programmable door entry strike time allows for 1-250 seconds, two auxiliary relay outputs, 12/24 VDC Power and built-in 10 Amp Form C (SPDT) door release relay. For use with: All DMP XR Series Panels. Color: White 734N-WIFI WIFI WIEGAND INTERFACE MODULE ORDER: 734N-WIFI The 734N-WiFi Module provides codeless entry plus system arming and disarming using DMP access cards or credentials; or customizable for other credentials. Provides programmable door entry strike time allows for 1-250 seconds, two auxiliary relay, 12/24 VDC Power and built-in 10 Amp Form C (SPDT) door release relay. PB-2 REX BUTTON The PB-2 exit control push-button features a 2" diagonal in wall button illuminated by a 25,000 hr. 12/24 VDC incandescent light bulb. The green push-button is mounted on a brushed stainless steel plate. OP-08C MOTION DETECTOR This high quality passive infrared sensor used for Request to Exit and security applications is compact and comes in an attractive housing. Offers an AC/DC universal power input, provides selectable Fail Safe or Fail Secure settings, and mounts on door moldings or ceilings up to 13 feet high. (12 or 24 VDC) 91 FAX: 800.743.5724 Slim line design and charcoal gray color of this proximity reader compliments any decor and is suitable for interior and exterior installation on wall or door mullions. Provides a multicolored LED and selectable sounder for read confirmation. Read range: 2" to 5". (4.75-16 VDC) Dimensions: 6.0" x 1.7" x 0.75" MX-5375 MAXIPROX™ READER ORDER: MP-5365 For use with: 734, 734N, 734N-WIFI, 7073, 7073A, 7173, and 7873 keypads. Color: Charcoal ORDER: MX-5375 Ideal for installations incorporating parking control and long read range applications. The MaxiProx reader packages all the electronics in one rugged, attractive and easy-to-install housing. Read Range: up to 8’. Use with the 1351 Prox Pass. (10-28.5 VDC) Dimensions: 11.8" x 11.8" x 1" For use with: 734, 734N, 734N-WIFI, 7073, 7073A, 7173, and 7873 keypads. PP-6005B PROXPOINT PLUS® READER ORDER: PP-6005B Color: Charcoal For use with: Any Key Fob or Credential. For use with: 734, and 734N 734N-WIFI/Wiegand Interface Modules, 7073, 7073A, 7163 and 7173 Keypads. The 734 Module allows you to connect Proximity Readers to DMP Panels to provide codeless entry, arming, and disarming using access control readers. Provides four programmable zones, a 10 Amp Form C (SPDT) Door Strike relay, built-in piezo with remote annunciation output, data to panel LED, and a 4-position terminal for connecting Wiegand format readers. (8.5-28.5 VDC) MP-5365 MINIPROX® READER For use with: All DMP XR Series Panels. Color: White Compact reader perfect for mounting to walls or door mullions and sealed in a weatherized case. Suitable for interior or exterior proximity access applications and provides a bi-color LED to indicate card read. Read range: 1" to 4". (4.75-16 VDC) Dimensions: 3.135" x 1.7" x 0.51" PR-5355-AGK14 PROXPRO READER WITH KEYPAD For use with: 734, 734N, 734N-WIFI, 7073, 7073A, 7173, and 7873 keypads. Color: Charcoal. Optional covers for purchase: gray (PP-G) and black (PP-B). ORDER: PR-5355-AGK14 The PR-5355 ProxPro® proximity card reader's weatherproof design and attractive enclosure allows easy mounting indoors or out. The ProxPro Reader features a read range of up to 8 inches and can be mounted on glass. Also offers a fully integrated personal identification number keypad for heightened security. Dimensions: 5" x 5" x 1". For use with: 733, 734, 734N, 734N-WIFI, 7073, 7073A, 7173, 7872 and 7873 Keypads. PR-5455 PROXPRO® II READER ORDER: PR-5455 Weatherproof design and long read range make this ideal for interior or exterior proximity access applications. Mounts to wall or single gang box and provides a multicolored LED and selectable sounder for confirmation. Internal tamper switch offers additional security. Read range: 4" to 8". (1028.5 VDC) Dimensions: 5.0" x 5.0" x 1.00" TL-5395 THINLINE II™ READER This switchplate size proximity reader provides an attractive, low profile option for residential and commercial applications. Mounts on a standard switchplate and provides a multicolored LED and selectable sounder for read confirmation. Read range: 2" to 5". (4.75-16 VDC) Dimensions: 4.70" x 3.00" x 0.68" Color: Charcoal. For use with: 734, 734N, 734N-WIFI, 7073, 7073A, 7173, and 7873 keypads. Color: Charcoal ORDER: TL-5395 For use with: 734, 734N, 734N-WIFI, 7073, 7073A, 7173, and 7873 keypads. Color: White ORDER: PB-2 For use with: All DMP XT Series and XR Series Panels. Color: Stainless steel with green button. ORDER: OP-08CB (BLACK) OP-08CW (WHITE) For use with: All DMP XT Series and XR Series Panels. CUSTOMER SERVICE: 866.266.2826 92 SWIPE TAP TWIST POINT TOUCH OR PUSH WITH CONFIDENCE. HID GLOBAL AD ENTRÉ SYSTEM SOFTWARE ENTRE LITE Access and Security Management Software with 16 doors included (16 doors max), up to 4 panels, 1 std client, badging, automation, image capture and alarm graphics (maps). Note: Certification and Dealer Agreement are required to purchase Entré. ENTRE BUSINESS Access and Security Management Software with 16 doors included (expandable to 96 doors max), up to 24 panels, 1 std client, badging, automation, image capture and alarm graphics (maps). Note: Certification and Dealer Agreement are required to purchase Entré. ENTRE ENTERPRISE Access and Security Management Software with 96 doors included (expandable to unlimited doors), unlimited panels, 1 std client, badging, automation, image capture and alarm graphics (maps). Note: Certification and Dealer Agreement are required to purchase Entré. ENTRE CENTRAL STATION Access and Security Management Software with 20 doors included (expandable to unlimited doors), unlimited panels & clients. Supports remote panel programming. Includes 1 std client, badging, automation, image capture and alarm graphics (maps). Note: Certification and Dealer Agreement are required to purchase Entré. ORDER: ENTRE LITE For use with: XR Series Panels. ORDER: ENTRE BUS ENTRE-BUS/UPGRADE For use with: XR Series Panels. ORDER: ENTRE ENT ENTRE-ENT/UPGRADE For use with: XR Series Panels. ORDER: ENTRE CS ENTRE-CS/10 For use with: XR Series Panels. * One XR500N/XR550N Control panel supports up to 16 Doors of Access using one model 734, 734N, or 734N-WIFI Door Module per door. One XR100N/XR150N Control panel will support up to 8 Doors of Access using one 734, 734N, or 734N-WIFI Door Module per door. ADDITIONAL MODULES (FOR USE WITH ALL ENTRÉ BASE SYSTEMS) MODEL DESCRIPTION SOFTWARE MODULES ENTRE-DVR DVR/NVR modules software ENTRE-LANG Multilanguage software ENTRE-PART Database partitioning ENTRE-PHOTO Events Photo Module USER EXPANSION MODULES ENTRE-STD Standard client (1) ENTRE-WEB Web Client (1) concurrent SYSTEM EXPANSION MODULES Technology is evolving and words like “interoperability” are taking on entirely new meaning. HID Global is leading the industry by developing the world’s broadest portfolio of truly scalable, fully interoperable secure identity solutions. We are connecting people to places with physical, mobile and virtual access solutions like never before—and we’re doing it with the most advanced layers of security anywhere on the planet. ENTRE-4DR 4 Door add on (for Entré Business, Enterprise, or Central Station) ENTRE-16DR 16 Door add on (for Entré Business, Enterprise, or Central Station) ENTRE-32DR 32 Door add on (for Entré Business, Enterprise, or Central Station) ENTRE-64DR 64 Door add on (for Entré Business, Enterprise, or Central Station) ENTRE-128DR 128 Door add on (for Entré Business, Enterprise, or Central Station) You’ll call it seamless end-to-end solutions. We call it, “your security connected.” YOUR SECURITY. CONNECTED 93 | Visit us at hidglobal.com/securityconnected FAX: 800.743.5724 CUSTOMER SERVICE: 866.266.2826 94 KEYPADS Model Series Zones Display Normal Internal Panic Type Backlight Relay Keys Wiegand Internal Compatible Input Prox Panels Keyboard Red In Alarm User Condition Brightness AQUALITE SERIES 9060 Wireless None LCD No Yes Yes 7060A AQUALITE™ KEYPAD Green No Yes No All 9063 Wireless None LCD Green No Yes No Yes All Yes Yes 7060 Thinline None LCD Green No Yes No No XT & XR Series Yes Yes 7063 Thinline None LCD Green No Yes No Yes XT & XR Series Yes Yes 7070 Thinline Four LCD Green No Yes No No XT & XR Series Yes Yes 7073 Thinline Four LCD Green Yes Yes Yes Yes XT & XR Series Yes Yes 7060A Aqualite None LCD Blue No Yes No No XT & XR Series Yes Yes 7063A Aqualite None LCD Blue No Yes No Yes XT & XR Series Yes Yes 7070A Aqualite Four LCD Blue No Yes No No XT & XR Series Yes Yes 7073A Aqualite Four LCD Blue Yes Yes Yes Yes XT & XR Series Yes Yes 7160 Thinline None LCD Green No Yes No No XT & XR Series Yes Yes 7173 Thinline Four LCD Green Yes Yes Yes Yes XT & XR Series Yes Yes 7360 Thinline Icon None LCD Green No Yes No No XT Series Yes Yes 7363 Thinline Icon None LCD Green No Yes No Yes XT Series Yes Yes 7872 Touchscreen Four LCD Blue Yes Yes No Yes XT & XR Series Yes Yes 7873 Touchscreen Four LCD Blue Yes Yes Yes Yes XT & XR Series Yes Yes 9862 Touchscreen None LCD Blue No Yes No Yes All Yes Yes 630F Fire Command None LCD Green No Yes No No XR Series No Yes 32-character alphanumeric LCD keypad in a sleek design with blue backlit keyboard, self-test diagnostics, three 2-button Panics, supervised or unsupervised operation, alert sounder, armed and AC LED. Keys with shortcut text makes system arming, fast and simple. Keypad turns red in alarm condition. (8.5-15 VDC) 9060 WIRELESS KEYPAD 9060-W/699 WIRELESS KEYPAD WITH DESKSTAND The DMP 9060 is a fully functioning supervised wireless keypad. 32-character alphanumeric LCD keypad in a sleek design with backlit keyboard, self-test diagnostics, three 2-button Panics, and alert sounder. Keypad turns red in alarm condition. (8.5-15 VDC) 9063 WIRELESS KEYPAD The DMP 9063 is a fully functioning supervised wireless keypad. 32-character LCD keypad in a sleek design with backlit keyboard, three 2-button Panic keys, and alert sounder. Built-in proximity card reader for codeless arming/disarming. Includes transformer. Keypad turns red in alarm condition. (8.5-15 VDC) 9063-W/699 WIRELESS KEYPAD WITH DESKSTAND The DMP 9063 is a fully functioning supervised wireless keypad. 32-character LCD keypad in a sleek design with backlit keyboard, three 2-button Panic keys, and alert sounder. Built-in proximity card reader for codeless arming/disarming. Includes transformer. Keypad turns red in alarm condition. (8.5-15 VDC) 95 FAX: 800.743.5724 ORDER: 9060-W For use with: XT, XTL, and XR Series Panels. For use with: All DMP XT Series and XR Series Panels. N indicates that the keypad comes with number keys only instead of the additional shortcut keys. 7063A AQUALITE™ KEYPAD 32-character LCD keypad in a sleek design with blue backlighting, three 2-button Panic keys, supervised or unsupervised operation, alert sounder, armed, and AC LED. Built-in proximity card reader for codeless arming/disarming. Keys with shortcut text makes system arming, fast and simple. Keypad turns red in alarm condition. (8.5-15 VDC) ORDER: 7063A-W 7063AN-W For use with: All DMP XT Series and XR Series Panels. N indicates that the keypad comes with number keys only instead of the additional shortcut keys. 7070A AQUALITE™ KEYPAD 32-character alphanumeric LCD keypad in a sleek design with blue backlit keyboard, four Class B zones, self-test diagnostics, three 2-button Panic keys, supervised or unsupervised operation, alert sounder, armed and AC LED. Keys with shortcut text makes system arming, fast and simple. Keypad turns red in alarm condition. Includes EOL resistors. (8.5-15 VDC) ORDER: 7070A-W 7070AN-W For use with: All DMP XT Series and XR Series Panels. N indicates that the keypad comes with number keys only instead of the additional shortcut keys. 7073A AQUALITE™ KEYPAD The DMP 9060 is a fully functioning supervised wireless keypad. 32-character alphanumeric LCD keypad in a sleek design with backlit keyboard, self-test diagnostics, three 2-button Panics, and alert sounder. Keypad turns red in alarm condition. (8.5-15 VDC) ORDER: 7060A-W 7060AN-W 32-character LCD keypad with blue backlit keys, self-test diagnostics, 2-button Panic keys, four Class B zones, Form C door access relay, supervised or unsupervised operation, alert sounder, and AC LED. Keys with shortcut text makes system arming, fast and simple. Builtin proximity card reader for codeless arming/disarming. Keypad turns red in alarm condition. (8.5-15 VDC) ORDER: 7073A-W 7073AN-W For use with: All DMP XT Series and XR Series Panels. N indicates that the keypad comes with number keys only instead of the additional shortcut keys. ORDER: 9060-W/699 For use with: XT, XTL, and XR Series Panels. ORDER: 9063-W For use with: XT, XTL, and XR Series Panels. 7073ANEE AQUALITE™ KEYPAD ORDER: 7073ANEE-W 32-character alphanumeric LCD keypad with blue backlit keys and special features for building access in retail and other types of businesses. It includes a momentary bypass feature that provides an entry and exit delay on systems with 24-hour perimeter protection. During entry, the delay allows the user to enter the code and on exit allows users to leave the building, both without disarming the system. For use with: All DMP XT Series and XR Series Panels. N indicates that the keypad comes with number keys only instead of the additional shortcut keys. ORDER: 9063-W/699 For use with: XT, XTL, and XR Series Panels. CUSTOMER SERVICE: 866.266.2826 96 KEYPADS THINLINE SERIES 7060 THINLINE™ KEYPAD 32-character alphanumeric LCD keypad in a sleek design with backlit keyboard, self-test diagnostics, three 2-button Panics, supervised or unsupervised operation, alert sounder, armed and AC LED. Keys with shortcut text makes system arming, fast and simple. Keypad turns red in alarm condition. (8.5-15 VDC) THINLINE SERIES ORDER: 7060-I 7060-W 7060N-I 7060N-W 7000 SERIES THIN LCD KEYPAD HOUSING Replacement keypad housing only. Optional French language label available part no. THIN-LCD-FRENCH For use with: All DMP XT Series and XR Series Panels. ORDER: THIN-LCD-I THIN-LCD-P/10 THIN-LCD-W THIN-LCD-B For use with: 7000 and 7000A Series keypads. N indicates that the keypad comes with number keys only instead of the additional shortcut keys. 7063 THINLINE™ KEYPAD 32-character LCD keypad in a sleek design with backlit keyboard, self-test diagnostics, three 2-button Panic keys, supervised or unsupervised operation, alert sounder, armed and AC LED. Built-in proximity card reader for codeless arming/disarming. Keys with shortcut text makes system arming, fast and simple. Keypad turns red in alarm condition. (8.5-15 VDC) ORDER: 7063-I 7063-W 7063N-I 7063N-W For use with: All DMP XT Series and XR Series Panels. 7160 THINLINE™ KEYPAD ORDER: 7160-W 32-character alphanumeric LCD keypad in a sleek design with backlit keyboard, self-test diagnostics, three 2-button Panics, supervised or unsupervised operation, alert sounder, armed and AC LED. Keypad turns red in alarm condition. (8.5-15 VDC) For use with: All DMP XT Series and XR Series Panels. N indicates that the keypad comes with number keys only instead of the additional shortcut keys. 7070 THINLINE™ KEYPAD 32-character alphanumeric LCD keypad in a sleek design with backlit keyboard, four Class B zones, self-test diagnostics, three 2-button Panic keys, supervised or unsupervised operation, alert sounder, armed and AC LED. Keys with shortcut text makes system arming, fast and simple. Keypad turns red in alarm condition. Includes EOL resistors. (8.5-15 VDC) ORDER: 7070-I 7070-W 7070N-I 7070N-W For use with: All DMP XT Series and XR Series Panels. 7173 THINLINE™ KEYPAD 32-character LCD keypad in a sleek design with backlit keyboard, self-test diagnostics, 2-button Panic keys, four Class B zones, Form C door access relay, supervised or unsupervised operation, alert sounder, and AC LED. Builtin proximity card reader for codeless arming/disarming. Keypad turns red in alarm condition. (8.5-15 VDC) ORDER: 7173-W For use with: All DMP XT Series and XR Series Panels. N indicates that the keypad comes with number keys only instead of the additional shortcut keys. 7073 THINLINE KEYPAD ™ 32-character LCD keypad in a sleek design with backlit keyboard self-test diagnostics, 2-button Panic keys, four Class B zones, Form C door access relay, supervised or unsupervised operation, alert sounder, and AC LED. Keys with shortcut text makes system arming, fast and simple. Built-in proximity card reader for codeless arming/ disarming. Keypad turns red in alarm condition. (8.5-15 VDC) ORDER: 7073-I 7073-W 7073N-I 7073N-W THIN LCD KEYSWITCH WITH NUMBERS ONLY ORDER: THIN-NBRKEYS/10 Replacement LCD keyswitch with numbers labeled only. Pack of 10. For use with: 7000 Series Keypads. THIN LCD KEYSWITCH WITH SHORTCUT KEYS ORDER: THIN-SCKEYS/10 For use with: All DMP XT Series and XR Series Panels. N indicates that the keypad comes with number keys only instead of the additional shortcut keys. Replacement LCD keyswitch with shortcut keys labeled only. Pack of 10. 97 FAX: 800.743.5724 For use with: 7000 Series Keypads. CUSTOMER SERVICE: 866.266.2826 98 KEYPAD COVERS THINLINE ICON SERIES 7360 THINLINE™ SERIES ICON KEYPAD ORDERING INFORMATION DESIGNER SERIES KEYPADS 7 0 0 0 D S - W T P 2 2 6 MODEL NUMBER Fixed Icon LCD keypad displays both intuitive symbols and messages for panel operation. Available in the Thinline Series plastics with green backlighting, selftest diagnostics, three 2-button Panics, supervised or unsupervised operation, alert sounder, and shortcut keys making operation faster for common arming functions. Keypad turns red in alarm condition. (8.5-15 VDC). 7363 THINLINE™ SERIES ICON KEYPAD Fixed Icon LCD keypad displays both intuitive symbols and messages for panel operation. Built-in proximity card reader for codeless arming/disarming. Available in the Thinline Series plastics, with green backlighting, self-test diagnostics, three 2-button Panics, supervised or unsupervised operation, alert sounder, and shortcut keys making operation faster for common arming functions. Keypad turns red in alarm condition. (8.5-15 VDC). Light Walnut WTP113 Medium Burl Wood WTP226 Brown Woodgrain WTP207 Cherry Burl Wood WTP195 Blonde Woodgrain WTP283 THINLINE ICON KEYPAD HOUSING ORDER: 7360-W For use with: XT Series Panels. ORDER: 7363-W For use with: XT Series Panels. ORDER: THIN-ICON-B/10 THIN-ICON-I/10 THIN-ICON-W/10 Replacement keypad housing only. Pack of 10. For use with: 7300 Series Keypads. 7800/9800 SERIES Mahogany WTP204 Dark Brown Woodgrain WTP291 Gray Woodgrain WTP130 Tan Desert Digital WTP274 Olive Desert Digital WTP382 7872 GRAPHIC TOUCHSCREEN KEYPAD A 5" touchscreen interactive display with a resistive screen. Suitable for access, burglary and household fire applications. Interactive shield for quick arming/ disarming along with a carousel menu for shortcut features. Display turns red in alarm. Support for 4 zones and internal proximity reader. 7873 GRAPHIC TOUCHSCREEN KEYPAD Oak Timber WTP310 Mothwing, Blaze Orange WTP311 Gods Country, Fall Oak GC-LS Carbon Fiber Check WTP174 Dark Green Marblee WTP202 99 Oak/Pine Camo WTP380 Carbon Fiber Weave WTP378 Black Granite WTP172 FAX: 800.743.5724 White Marble WTP201 Clouds WTP175 Blue Bandana YH1476 Diamond Plate WTP282 Pink Camo WTP384 Snakeskin Gray WTP134 A 5" touchscreen interactive display with a resistive screen. Suitable for access, burglary and household fire applications. Interactive shield for quick arming/ disarming along with a carousel menu for shortcut features. Display turns red in alarm. Support for 4 zones, internal proximity reader, wiegand input, and internal door strike. ORDER: 7872-B 7872-W For use with: XT & XR Series Panels. ORDER: 7873-B 7873-W For use with: XT & XR Series Panels. 7872 DEMO KEYPAD ORDER: 7872-W/DEMO 9862 GRAPHIC TOUCHSCREEN KEYPAD ORDER: 9862-B 9862-W 9862-W/699 A 5" touchscreen interactive display with a resistive screen. Suitable for access, burglary and household fire applications. Interactive shield for quick arming/ disarming along with a carousel menu for shortcut features. Dispturns red in alarm. This keypad can be used for hands-on customer sales demonstrations and security system training.The fully portable keypad demonstrator allows customers to personally experience how easy a security system can be to operate. A 5" wireless touchscreen interactive display with a resistive screen. Suitable for access, burglary and household fire applications. Interactive shield for quick arming/disarming along with a carousel menu for shortcut features. Display turns red in alarm. (with deskstand) For use with: XT, XTL, and XR150|XR550 Series. CUSTOMER SERVICE: 866.266.2826 100 KEYPADS ACCESSORIES FIRE COMMAND SERIES 630F REMOTE ANNUNCIATOR The 32-character LCD readout with full-text displays of system events and menu prompts. The 630F is protected by either keyswitch or code. The keyswitch enables single-button user operation of the Alarm Silence, System Reset, System Test, and Fire Drill. Backbox and trim frame included for in wall installations. (8-16 VDC) 635 KEYPAD SURFACE MOUNT CONDUIT BACKBOX A 1.75" deep metal backbox for installations requiring conduit or for mounting keypads on masonry walls or other penetrable surfaces. The 635 provides five 3/4" x 3/4" knockouts and four mounting holes. Dimensions: 10.25" W x 6.88" H x 1.74" D 635-S BRUSHED STAINLESS STEEL KEYPAD HOUSING Replacement keypad housing only for in wall installation. ACCESSORIES CONT. ORDER: 630F-R For use with: XR Series Panels. 300-7800-12 REPLACEMENT 12 WIRE HARNESS ORDER: 300-7800-12 300-9800-4 REPLACEMENT 4 WIRE HARNESS ORDER: 300-9800-4 371-500 12 VDC PLUG-IN TRANSFORMER ORDER: 371-500 A 12 VDC DC Plug-in Power Supply for 9000 Series Wireless Keypads. For use with: 9000 Series. 694 METAL KEYPAD BACKPLATE ORDER: 694-W For use with: 7800 Series. Replacement 12-wire keypad harness. Replacement Keys Only: SW-0181 (set of 2) ORDER: 635-R For use with: 9800 Series. Replacement 4-wire keypad harness. For use with: 630F Keypads. ORDER: 635-S For use with: 630F Keypads. White metal keypad backplate for retrofit installations. Dimensions: 8.25" W x 6.5" H 635F IN WALL MOUNT BACKBOX A 2.50"deep in wall mount metal backbox for installation requiring conduit. The 635 provides five 3/4" x 3/4" knockouts and four mounting holes. Dimensions: 9.25" x 6.375 x 2.50" ORDER: 635F-R For use with: 630F Keypads. Replacement 12-wire keypad harness. 300-5 REPLACEMENT READER HARNESS Replacement 5-wire keypad to reader harness. 300-512 REPLACEMENT HARNESS Five foot 12-wire replacement harness for ease of installer connection of keypad above ceiling. 695 KEYPAD CONDUIT BACKBOX A 1.5" deep metal backbox for installations requiring conduit or for mounting keypads on masonry walls or other non-penetrable surfaces. The 695 provides three 1/2" x 3/4" knockouts and four mounting holes. Dimensions: 6.75"W x 5.0"H x 1.5"D ACCESSORIES 300-12 REPLACEMENT HARNESS ORDER: 300-12 For use with: 7070, 7070A, 7073, 7073A, 7170, and 7173 keypads. 695-7800 IN WALL MOUNT BACKBOX For in wall keypad installations where the consumer wants a higher end look. The 7800 keypad quickly snaps into the backbox for a built-in designer look. Dimensions: 6.385" W x 4.725" H x 1.565" D Replacement 5-wire keypad to reader harness. For use with: 7073, 7073A, and 7173 keypads. ORDER: 300-512 For use with: 7070, 7070A, 7073, 7073A, 7170 and 7173 keypads. 696 KEYPAD BACKBOX ORDER: 300-7800-5 Plastic keypad backplate for retrofit installations. Dimensions: 9" x 9" ORDER: 695-7800-W 695-7800-B ORDER: 696-B 696-I 696-W For use with: LCD Keypads. ORDER: 697 For use with: LCD Keypads. For use with: 7800 Series. Plastic keypad backplate for retrofit installations. Dimensions: 7.4" x 11" FAX: 800.743.5724 For use with: LCD Keypads. For use with: 7800 Series. A 0.5" deep metal backbox for mounting DMP keypads on masonry walls or other non-penetrable surfaces. Provides one 0.75" hole for running wires and four mounting holes. Dimensions: 6.75"W x 5.0"H x 0.5"D 698 KEYPAD BACKPLATE 101 ORDER: 695-B 695-I 695-W ORDER: 300-5 697 KEYPAD BACKPLATE 300-7800-5 REPLACEMENT 5 WIRE HARNESS For use with: LCD Keypads. ORDER: 698 For use with: LCD Keypads. CUSTOMER SERVICE: 866.266.2826 102 AUXILIARY MODULES ACCESSORIES CONT. 699 KEYPAD DESKSTAND Smoked plexiglass deskstand provides attractive, portable mounting option for DMP keypads. Includes mounting screws and rubber pads, and a 4-foot long cord for plugging into RJ11 jack. Dimensions: 6.8" W x 4" H x 5" D 699 WHITE KEYPAD DESKSTAND Steel deskstand provides attractive, portable mounting option for DMP keypads. Includes mounting screws and rubber pads, and a 4-foot long cord for plugging into RJ11 jack. Dimensions: 6.8" W x 4" H x 5" D 698-7800 PLASTIC KEYPAD WALL COVER Plastic keypad backplate to retrofit existing 7000 Series installations to the 7800 Touchscreen. Covers screw holes and paint outline of the 7000 Series Keypad. AUXILIARY MODULES ORDER: 699 For use with: LCD Keypads. ORDER: 699-W For use with: LCD Keypads. 370 LIGHTNING SUPPRESSOR ORDER: 370 External lightning suppressor for use with any DMP or other manufacturer’s panel. Provides transient protection and RF isolation on both AC power and telephone lines. Phone, AC, and ground wires connect to on-board terminal strips. For use with: All DMP XT Series and XR Series Panels. 370RJ LIGHTNING SUPPRESSOR ORDER: 370RJ External lightning suppressor for use with any DMP or other manufacturer’s panel. Provides transient protection and RF isolation on both AC power and telephone lines. Phone lines connect to modular jacks while AC and ground wires connect to on-board terminal strips. 270 NETWORK TRANSIENT SUPPRESSOR ORDER: 698-7800-W 698-7800-B The Model 270 Transient Suppression Module provides surge suppression from the ethernet for the protection of DMP Panels. In UL applications, the Model 270 must be used if the switch is not installed in the same room as the panel. Deskstand provides attractive, portable mounting option for DMP keypads. Includes mounting screws and rubber pads, and a 4-foot long cord for plugging into RJ11 jack. ORDER: 699-7800 The Model 277 Trouble Sounder is an audible trouble alert that may may be installed in place of the Model 893A Module for XR150|XR550 Series control panels. Clear thick polycarbonate cover with thumb lock for all DMP keypads. Dimensions: 9.75" W x 8.5" H x 2" D 780 PORTABLE KEYPAD DEMONSTRATOR MODULE This portable Keypad Demonstrator Module connects to any DMP 32-character LCD keypad or 7800 Graphic touchscreen keypad. You can show—not just tell—how DMP keypads provide security in Area, All/Perimeter, or Home/Sleep/Away modes. Simulate arming and disarming to demonstrate ease of system operation. Keypad not included. ORDER: 777 For use with: LCD keypads. ORDER: 780 For use with: LCD and 7800 Keypads. Can be used for electrical isolation between the alarm panel and other systems or for switching voltage to control various functions. Includes one relay and provides three additional sockets for expansion of up to four relays. (12 VDC) For use with: XR150|XR550 Series Panels. ORDER: 860 For use with: All DMP XT Series and XR Series Panels. ORDER: 861 Provides multiple auxiliary power terminals and additional Keypad and/or LX-Bus connectors for a clean installation. Maximum current handling capacity of 8 Amps on terminal J1. (12 VDC or 24 VDC) For use with: All DMP XT Series and XR Series Panels. 865 STYLE W/X NOTIFICATION MODULE ORDER: 865 Provides supervision for ground faults, opens, and shorts on notification appliance circuits. Suitable for use with 2 or 4-wire 12 or 24 VDC circuits. Provides Trouble and Ground Fault LEDs, Bell Silence switch, and N/C dry contact trouble contacts. (9.6-14.2 VDC) Supervises one Style W Notification circuit for opens, shorts and ground faults. Capable of switching 12 VDC internal or 24 VDC external power supply. Provides dry contact output for external bell trouble condition and manual bell silence switch. (12 VDC) 867 LX-BUS™ ADDRESSABLE NOTIFICATION MODULE For use with: All DMP XT Series and XR Series Panels. ORDER: 866 For use with: All DMP XT Series and XR Series Panels. ORDER: 867 Provides one supervised Style W circuit for 12 or 24 VDC notification devices. The 867 connects to the LX-Bus™ and provides supervision for ground fault, open, and short conditions on the notification circuit. (12 VDC) FAX: 800.743.5724 ORDER: 277 861 POWER DISTRIBUTION/4 WIRE BUS MODULE 866 STYLE W NOTIFICATION MODULE 103 For use with: XR150|XR550 Series Panels. For use with: 7800 series. 860 RELAY OUTPUT MODULE 777 PROTECTIVE KEYPAD COVER ORDER: 270 For use with: 7800 series. 277 TROUBLE ANNUNCIATOR 699-7800 KEYPAD DESKSTAND WITH CORD For use with: All DMP XT Series and XR Series Panels. For use with: XR Series Panels. CUSTOMER SERVICE: 866.266.2826 104 AUXILIARY MODULES CONT. 869 STYLE D INITIATING MODULE Provides two Style D initiating 4-wire circuits for connecting waterflow switches and non-powered burglary and fire devices. The 869 supervises both zones for opens, shorts, and ground fault conditions. (8-25 VDC) 893A DUAL PHONE LINE MODULE The 893A installs into the panel enclosure and connects to the panel through a wire harness and phone cord. The 893A supervises the main and backup phone lines for sustained drop in voltage and alerts users with a built-in sounder and indication at the keypad and central station. (12 VDC) ORDER: 869 For use with: XR Series Panels. ORDER: 893A For use with: XR Series Panels. EXPANSION MODULES 708 BUS EXTENDER MODULES FREE FREIGHT AVAILABLE TO QUALIFYING DEALERS1 FREE domestic Ground freight on all orders over $15002. Use the 708 Modules in applications such as long wire runs between buildings, in noisy environments, or where the LX-Bus™ is run bundled with other wires, such as telephone company wire. Mounted in two-piece, high-impact ivory plastic case for easy installation. Two 708 Modules included. (8-15 VDC) 710 BUS SPLITTER/REPEATER MODULE Allows you to expand the typical LX-Bus™ or Keypad bus installation number of devices and the length of wire. As a splitter, the 710 provides superior mechanical wire connecting capability for up to three additional LX-Bus™ circuits. Mounted in two-piece, high-impact ivory plastic case for easy installation. (8-15 VDC) 711 ZONE EXPANSION MODULE Single-zone expander with rotary-switch addressing and convenient screw terminal connections. Mounted in twopiece, high-impact ivory plastic case for easy installation. Includes EOL resistors. (8.8-15 VDC) FREE domestic Ground freight on all orders for dealers who average purchases of $10,000 per month over the previous 6 months. As always, DMP will offer FREE domestic Ground freight on all orders for dealers who use Electronic Funds Transfer (EFT). For information on signing up for EFT, please contact Accounts Receivable at 800-367-4850. 712-8 ZONE EXPANSION MODULE Addressable expander with eight grounded burglary zones with dip switch addressing. Provides 3-hole pattern for simple installation in panel enclosure. Includes EOL resistors. (8.5-15 VDC) 714 ZONE EXPANSION MODULE Expander with four 5 VDC Class B zones and rotary-switch addressing. Mounted in high impact plastic case for easy installation. The module snaps into the cover allowing installation with base or directly onto a wall or switch plate. Includes EOL resistors and 12-wire harness. (8.5-15 VDC) 714-8 SERIES ZONE EXPANSION MODULE 1 Qualifying dealers with current accounts in good standing with open credit terms: COD and Credit Card terms do not qualify. 2 DMP reserves the right to ship with carrier of choice; If the dealer chooses method of deliver, dealer incurs all costs. 105 FAX: 800.743.5724 Terminal block installation for eight burglary or Class B non-powered fire devices. 20-gauge enclosure with 1/2" or 3/4" conduit knockouts. Includes enclosure with lock and key plus EOL resistors. (8.8-15 VDC) ORDER: 708 For use with: All Keypad Bus and LX-Bus™ circuits. ORDER: 710 For use with: All Keypad Bus and LX-Bus™ circuits. ORDER: 711 For use with: All DMP XT Series and XR Series Panels. ORDER: 712-8 For use with: All DMP XT Series and XR Series Panels. ORDER: 714 For use with: All DMP XT Series and XR Series Panels. ORDER: 714-8 (8 ZONE) 714-8-R 714-8L-G 714-8L-R 714-8PCB For use with: All DMP XT Series and XR Series Panels. CUSTOMER SERVICE: 866.266.2826 106 MODULES & EXPANSION EXPANSION MODULES CONT. 714-16 SERIES ZONE EXPANSION MODULE Terminal block installation for sixteen burglary or Class B non-powered fire devices. 20-gauge enclosure with 1/2" or 3/4" conduit knockouts. Includes enclosure with lock and key plus EOL resistors. (8.8-15 VDC) EXPANSION MODULES CONT. ORDER: 714-16 (16 ZONE) 714-16-R 714-16L-G 714-16L-R 714-16PCB For use with: All DMP XT Series and XR Series Panels. 714-18T ZONE EXPANSION MODULE The 714 Zone Expansion Module with the 718T Plug-in Screw Terminal. Four 5 VDC powered zones, 12-wire harness, and rotary-switch addressing with screw-type terminal connection for 14 to 22-gauge device wiring. (8.8-15 VDC) 714-19T ZONE EXPANSION MODULE The 714 Zone Expansion Module with the 719T Terminal Board. Four 5 VDC powered zones, 12-wire harness, and rotary-switch addressing with dual terminal strips. (8.8-15 VDC) 714-X ZONE EXPANSION MODULE Four 5 VDC Class B zones and rotary-switch addressing. Module and harness, mounted in snap-track housing. Includes 12-wire harness. (No enclosure, Non-UL, 8.8-15 VDC) 715 ZONE EXPANSION MODULE Four 12 VDC Class B zones for 2-wire smoke detectors and other powered or non-powered devices. Rotary-switch addressing. The module snaps into cover for installation with base or directly onto wall or switch plate. Includes 3.3k EOL resistors and 12-wire harness. (8.8-15 VDC) 715-8 SERIES ZONE EXPANSION MODULE Terminal block installation in a standard enclosure for eight 12 VDC powered zones supporting two-wire smoke detectors or other fire alarm initiating devices. 20-gauge enclosure with 1/2" or 3/4" conduit knockouts. Includes 340 Red enclosure with lock and key plus EOL resistors. (9.9-15 VDC) 715-18T ZONE EXPANSION MODULE The 715 Zone Expansion Module with the 718T Plug-in Screw Terminal. Four 12 VDC Class B zones and rotary-switch addressing with screw-type terminal connection for 14 to 22-gauge device wiring. (9.9-15 VDC) 715-20T ZONE EXPANSION MODULE The 715 Zone Expansion Module with the 720T Terminal Board. Four 12 VDC Class B zones and rotary-switch addressing with dual terminal strips. (9.9-15 VDC) 107 FAX: 800.743.5724 ORDER: 714-18T 716 OUTPUT EXPANSION MODULE For use with: All DMP XT Series and XR Series Panels. ORDER: 714-19T 718T PLUG-IN SCREW TERMINAL ORDER: 714-X 714-X-18T For use with: All DMP XT Series and XR Series Panels. ORDER: 715 For use with: All DMP XT Series and XR Series Panels. ORDER: 715-8 (8 ZONE) 715-8PCB 715-16 (16 ZONE) 715-16PCB For use with: All DMP XT Series and XR Series Panels. ORDER: 715-18T For use with: All DMP XT Series and XR Series Panels. ORDER: 715-20T For use with: All DMP XT Series and XR Series Panels. For use with: All LX-Bus™ circuits. 717 GRAPHIC ANNUNCIATOR MODULE Provides twenty annunciator outputs (open collector) that follow the armed or bypassed state of the panel’s zones. Multiple 717 Modules can be installed to remotely annunciate every zone in the system. (8.8-15 VDC) For use with: All DMP XT Series and XR Series Panels. ORDER: 716 Four programmable Form C (SPDT) relays and four open collector annunciator outputs on one module. Use the outputs for remotezone and system annunciation or environmental control applications. Harness included. (8.8-15 VDC) ORDER: 717 For use with: All LX-Bus™ circuits. ORDER: 718T Plugs onto 714 or 715 Zone Expansion Module header to provide a screw-type terminal connection for 14 to 22-gauge device wiring. To order with the 714 or 715 Modules, specify 714-18T or 715-18T. For use with: 714 and 715 Zone Expander Modules. 719T TERMINAL BOARDS ORDER: 719T Dual terminal strips allow wiring from zones on 714 Zone Expanders and pass through wiring from panel’s LX-Bus. Accommodates 14 to 22-gauge wire and provides individual 1K EOL resistors for zone termination and dual-ended 12-wire harness. To order with the 714, specify 714-19T. For use with: 714 Zone Expander Modules. 721T TERMINAL STRIP ORDER: 721T Terminal strip for wiring from zones on the panel. The terminal strip accommodates 14 to 22 gauge wire and provide individual EOL resistors for zone termination. For use with: XR Series Panels. 736P RADIONICS™ POPIT INTERFACE MODULE ORDER: 736P Allows existing POPIT, POPEX, and OctoPOPIT modules and wiring to be left while upgrading the Radionics control panel to a DMP panel. Supervises up to 100 POPIT zones from the DMP LX-Bus™ and up to 32 zones on the Keypad Bus. (12 VDC) For use with: All DMP XT Series and XR Series Panels. 738A ADEMCO™ INTERFACE MODULE ORDER: 738A Allows up to 32 zones of Ademco series 5800 wireless devices to DMP XT Series and XR Series panels. Includes two Model 300 4-wire harnesses. (12 VDC) For use with: All DMP XT Series and XR Series Panels. 738I ITI™ INTERFACE MODULE ORDER: 738I Allows you to incorporate up to 96 zones of ITI™ wireless devices to DMP panels. Includes two Model 300 4-wire harnesses. (12 VDC) For use with: All DMP XT Series and XR Series Panels. CUSTOMER SERVICE: 866.266.2826 108 POWER SUPPLIES EXPANSION MODULES CONT. 738Z Z-WAVE MODULE ® The 738Z Z-Wave Interface Module provides communication with up to 232 Z-Wave devices such as light controls, door locks, and thermostats for residential or small commercial installations. The 738Z easily connects to the panel s keypad bus and unifies the control of home electronics using an integrated wireless network. Now, devices can be remote controlled from an Apple iPAD/iPhone and Android using the DMP Virtual Keypad application or from any cell phone using MyAccess text commands. BATTERIES ORDER: 738Z For use with: All DMP XT, XR150|XR550, and XTL Panels. 366 18.0 AH 12 VDC LEAD-ACID BATTERY Single 12 VDC, 18.0 Ah sealed lead-acid battery. Ring style connection. (12 VDC) For use with: All DMP XT Series and XR Series Panels. 368 5.0 AH 12 VDC LEAD-ACID BATTERY Single 12 VDC, 5.0 Ah sealed lead-acid battery. (12 VDC) 369 7.0 AH 12 VDC LEAD-ACID BATTERY Single, affordable, 12 VDC, 7.0 Ah sealed lead-acid battery. (12 VDC) BATTERIES 318 BATTERY HARNESS Allows you to connect two batteries to the panel’s standard battery leads. Suitable for use in fire applications. 318EXT BATTERY HARNESS EXTENSION For use with: All DMP XT Series and XR Series Panels. Allows you to connect two batteries with ring-style battery leads to the panel. Suitable for use in fire applications. ORDER: 318EXT For use with: All DMP XT Series and XR Series Panels. The 505-12 is a power limited, switching power supply that meets UL, CSFM, NFPA, and FCC compliance standards. 505-12 is rated for 12 VDC @ 5 Amps maximum. Each power supply includes a transformer, battery leads, and a metal enclosure. (115 VAC, 12 VDC) ORDER: 318R For use with: All DMP XT Series XR Series Panels and Model 366 Battery. The 505-12 is a power limited, switching power supply that meets UL, CSFM, NFPA, and FCC compliance standards. Installed in a 350 (L) or 350A (A) enclosure to allow adequate space for up to two back-up batteries and includes a transformer and battery leads. The 505-12 is rated for 12 VDC @ 5 Amps maximum. (115 VAC, 12 VDC) 505-12LX POWER SUPPLY 318T BATTERY HARNESS Allows you to connect two batteries to the panel's battery terminals. Suitable for use in fire applications. 364 1.3 AH 12 VDC BATTERY Single 12 VDC, 1.3 Ah sealed lead-acid battery. ORDER: 318T For use with: All DMP XT Series and XR Series Panels. ORDER: 364 For use with: 341B battery bracket. The 505-12LX is a power limited, switching power supply that meets UL, CSFM, NFPA, and FCC compliance standards. 505-12LX is rated for 12 VDC @ 5 Amps maximum. Provides two independent Class B NAC outputs. Each power supply includes a transformer, battery leads, and a metal enclosure. (115 VAC, 12 VDC) Single 12 VDC, 9.0 Ah sealed lead-acid battery. (12 VDC) 109 FAX: 800.743.5724 ORDER: 369 For use with: All DMP XT Series and XR Series Panels. ORDER: 505-12-G 505-12PCB 505-12-R For use with: All DMP XT Series and XR Series Panels. ORDER: 505-12A-G 505-12L-G 505-12L-R For use with: All DMP XT Series and XR Series Panels. ORDER: 505-12LX-G 505-12LX-R For use with: All DMP XR Series Panels. TRANSFORMERS 320 40 VA WIRE-IN TRANSFORMER A 16 VAC, 40 VA transformer for DMP XT Series panels. Can be required by the Authority Having Jurisdiction (AHJ) on fire systems. 365 9.0 AH 12 VDC BATTERY For use with: All DMP XT Series and XR Series Panels. POWER SUPPLIES 505-12 POWER SUPPLY 318R BATTERY HARNESS ORDER: 368 ORDER: 318 505-12 POWER SUPPLY 48" extension allows you to extend the panels battery wires. ORDER: 366 ORDER: 320 For use with: XT Series Panels. ORDER: 365 For use with: All DMP XT Series and XR Series Panels. 321 40 VA PLUG-IN TRANSFORMER ORDER: 321 A 16.5 VAC, 40 VA Transformer for XT Series panels. Screw to secure to outlet included. For use with: XT Series Panels. CUSTOMER SERVICE: 866.266.2826 110 FIRE DEVICES TRANSFORMERS CONT. 322 56 VA WIRE-IN TRANSFORMER A 16 VAC, 56 VA Transformer for use with XR Series panels when charging two or more batteries. Features a built-in PTC. Mounted in enclosure. Dimensions: 6.2" x 6.2" x 3" 323 56 VA WIRE-IN TRANSFORMER A 16 VAC, 56 VA Transformer for use with XR Series panels when charging two or more batteries. Preassembled on a mounting plate. Mounts into 341, 350, or 350A enclosure ordered separately. 324 100 VA WIRE-IN TRANSFORMER A 16 VAC, 100 VA transformer for use with DMP XR Series panels when charging four or more batteries. Features a built-in PTC. Mounted in an enclosure and meets UL and NFPA compliance standards. 324P 100 VA WIRE-IN TRANSFORMER A 16 VAC, 100VA transformer for use with DMP XR Series panels when charging four or more batteries. Mounted on a mounting plate for installation in a 350 large enclosure. TRANSFORMERS CONT. ORDER: 322 For use with: XR Series Panels. Color: Gray ORDER: 323 For use with: XR Series Panels. ORDER: 324 For use with: XR Series Panels. 376 12 VOLT WALL PLUG-IN POWER SUPPLY A 12 Volt DC 600 MA adapter for use with a Barrel Jack Connector. For use with: 1100R Wireless Receivers 376L 12 VOLT WALL PLUG-IN POWER SUPPLY 12 Volt DC Adapter Power Supply with flying leads. A 2-position terminal strip with safety cover for use with the Model 350 and 350A Large Enclosures when connecting 120 VAC line voltage to a wire-in transformer. Transformer bracket included. 378 BARREL CONNECTOR WITH CORD Provides an optional connection to a 12 VDC Power Supply. A 16.5 VAC, 50 VA Transformer for use with XR Series panels when charging two or more batteries. 111 FAX: 800.743.5724 ORDER: 378 For use with: 1114, 1116, 1117 and 1118 Wireless Modules. ORDER: 324P For use with: XR Series Panels. DETECTORS ORDER: 325 For use with: 350 and 350A Large Enclosure. The 2W-BLX smoke detector is an addressable photoelectric detector that incorporates a state-of-the-art optical sensing chamber and an advanced microprocessor. It includes an addressable single point module for connection to the LX-Bus of the XR Series Panels. 2WT-BLX PHOTOELECTRIC SMOKE DETECTOR 327 50 VA PLUG-IN TRANSFORMER ORDER: 376L For use with: 1100R Wireless Receivers. 2W-BLX PHOTOELECTRIC SMOKE DETECTOR 325 TERMINAL STRIP WITH COVER ORDER: 376 ORDER: 327 327-CAN For use with: XR Series Panels. The 2WT-BLX smoke detector is an addressable photoelectric detector that incorporates a state-of-theart optical sensing chamber and an advanced microprocessor. It includes an addressable singlepoint module for connection to the LX-Bus of the XR Series Panels. The Model 2WT-BLX features a restorable, built-in, fixed temperature thermal detector and is capable of sensing a temperature higher than 135 degrees Fahrenheit. ORDER: 2W-BLX For use with: XR Series Panels. Color: White ORDER: 2WT-BLX For use with: XR Series Panels. Color: White CUSTOMER SERVICE: 866.266.2826 112 FIRE DEVICES PULL STATIONS CONT. PULL STATIONS 850-AR SCORED ACRYLIC BREAKRODS Replacement breakrods for all 850 series pull stations. Packaged in cartons of 12. 850D MANUAL PULL STATION DUAL ACTION A high quality, die-cast metal, dual-action manual pull station with SPST contacts and terminal strip connections. Contacts are gold plated to avoid corrosion. The 850D is in compliance with the latest requirements of the ADA. 850D/711 DUAL ACTION MANUAL PULL STATION WITH ZONE EXPANDER The 850D dual-action manual pull station with SPST contacts, terminal strip connections, and gold plated contacts to avoid corrosion. Includes one 711 Zone Expander for addressable applications. ORDER: 850-AR For use with: All 850 Series Pull Stations. ORDER: 850D For use with: All DMP XT Series, and XR Series Panels. ORDER: 850D/711 For use with: All DMP XT Series, and XR Series Panels. 850S MANUAL PULL STATION SINGLE ACTION ORDER: 850S A high quality, die-cast metal, single-action manual pull station with SPST contacts and terminal strip connections. Contacts are gold plated to avoid corrosion. The 850S is in compliance with the latest requirements of the ADA. For use with: All DMP XT Series, and XR Series Panels. 850S/711 SINGLE ACTION MANUAL PULL STATION WITH ZONE EXPANDER ORDER: 850S/711 The 850S single-action manual pull station with SPST contacts, terminal strip connections, and gold plated contacts to avoid corrosion. Includes one 711 Zone Expansion Module for addressable applications. For use with: All DMP XT Series, and XR Series Panels. 850-SB SURFACE MOUNT BACKBOX ORDER: 850-SB A 1 1/2" deep indoor backbox for installations requiring surface mountings on masonry or other non-penetrable surfaces. 850-WP SURFACE MOUNT WEATHERPROOF BACKBOX A 1 1/2" deep indoor/outdoor backbox for installations requiring outdoor surface mountings on masonry or other exterior non-penetrable surfaces. For use with: All 850 Series Pull Stations. ORDER: 850-WP For use with: All 850 Series Pull Stations. USER KNOWS BEST The central station saw a person, your customer saw a trusted employee. With video verification in the app, your customers can instantly view live video in real-time allowing them to quickly cancel or verify an alarm from anywhere. Just one of the dozens of powerful features you will find in the Virtual Keypad App. Learn more at dmp.com/videoverification 113 FAX: 800.743.5724 CUSTOMER SERVICE: 866.266.2826 114 INTRUSION DEVICES ACCESSORIES 309 3.3K OHM REPLACEMENT RESISTOR 300 REPLACEMENT HARNESS Replacement 4-wire harness. ORDER: 300 One replacement resistor for a 715 Zone Expansion Module zone or the powered zone on a panel. For use with: For use with: All DMP XT Series, XR Series Panels, and the 715 Zone Expansion Module. For use with: DMP Keypads, Modules, and Panels. 310 1K OHM REPLACEMENT RESISTOR 301 REPLACEMENT ENCLOSURE LOCK AND KEY Replacement lock and key for DMP enclosures. ORDER: 301 ORDER: 309 ORDER: 310 310/25 One 1k Ohm resistor with wire leads. For use with: All DMP XT and XR Series Panels. For use with: All DMP metal enclosures. Replacement Key Only: HM-0162. 311 PACK OF TEN EOL RESISTORS 302 TWO-PIN JUMPER ORDER: 302 Package of ten 2-pin jumpers. Strip of ten 1k Ohm resistors for burglary zones on panels. For use with: 2-pin headers on all DMP XT and XR Series Panels, Interface Cards, and Modules. 303 SILENCE/RESET PUSH BUTTON KIT The DMP Model 303 Silence/Reset Push Button provides the ability to silence bells and reset sensors using a zone input on the DMP panel. Adding the push-button switch allows the bells to be silenced and the sensors to be reset without using a keypad. (N/O) 305 PLUG-IN OUTPUT RELAY Provides one set of Form C (SPDT) contacts. ORDER: 303 ORDER: 311 For use with: All DMP XT and XR Series Panels. 312/25 470K OHM REPLACEMENT RESISTOR ORDER: 312/25 Package of 25 470K Ohm EOL resistors with wire leads. For use with: 1103 Wireless Transmitter. 319 PACKAGE OF FUSES ORDER: 319 For use with: XR Series Panels. ORDER: 305 305/10 (PKG OF 10) Package of five 3 Amp fuses for use with the DMP SCS-1R Receiver. For use with: The DMP SCS-1R Receiver. 330 PROGRAMMING CABLE ORDER: 330 330-4 (4 FT) For use with: XR Series Panels and the 860 Relay Output Module. 306 TAMPER HARNESS A 2-wire harness for connecting to the on-board tamper header. ORDER: 306 For use with: All DMP XT Series and XR Series Panels. A dual-ended 4-wire cable that allows you to quickly and easily connect a variety of devices for programming and installation purposes. 335 INTERIOR SIREN 307 CLIP-ON TAMPER SWITCH Clip-on tamper switch with harness and header connector. ORDER: 307 For use with: All DMP XT Series and XR Series Panels. The 335 Interior Siren offers dual tones, steady and warble, is load-tested to four hours, is indoor surface mounted, and is made out of UV resistant, high impact ABS plastic. 105 db. (12-16 VDC) 356 RJ PHONE CABLE 307-S SCREW-ON TAMPER SWITCH Screw-on tamper switch with harness and header connector. Model 306 harness needed for connection to DMP panel. 308 10K OHM REPLACEMENT RESISTOR One 10k Ohm EOL resistor with wire leads. 115 FAX: 800.743.5724 ORDER: 307-S Telephone cable for connecting Interface Cards and panels to RJ31X and RJ38X telephone jacks. For use with: All DMP XT Series and XR Series Panels. ORDER: 308 For use with: 865, 866, 867 Notification Modules. 357 CAT-5 CABLE Cat-5 cable for XT Series, XR Series Panels. For use with: Keypads, Modules, and panels. ORDER: 335 For use with: All DMP XT and XR Series Panels. Color: White ORDER: 356-2 (2 FT) 356-7 (7 FT) For use with: All DMP XT Series, XR Series Panels, 370RJ Lightning Suppressor Module, and 893A Dual Phone Line Modules. ORDER: 357-3 (3 FT) 357-10 (10 FT) For use with: All DMP XT and XR Series Panels. CUSTOMER SERVICE: 866.266.2826 116 INTRUSION DEVICES ACCESSORIES CONT. CAT-5 CABLE ORDER: 357-X (5 FT) 357-X-10 (10 FT) Crossover Cat-5 cable for XR Series Panels. Allows programming directly from a laptop NIC card without a network. For use with: XR Series Panels. 358 RJ PHONE BLOCK ORDER: 358 Provides connection of phone lines to DMP panels. For use with: All DMP XT and XR Series Panels. 374 SURGE VOLTAGE SUPPRESSOR ORDER: 374 Provides transient voltage protection to panels across phone and low voltage AC transformer wires. For use with: All DMP XT and XR Series Panels. 390 STANDARD 462N DATA CABLE ORDER: 390 Provides RS-232 connection from 462N Interface to Data Communication Equipment (DCE) type equipment. DB-25 connector. For use with: Type DCE equipment. 393 PRINTER DATA CABLE ORDER: 393 Use with Model 462P to provide printer output from the panel. Replacement data cable for Model 462P Printer Interface Card. DB-25 connector. 394 DIRECT PROGRAMMING CABLE Use with Model 462N Network Interface Card to provide direct programming from Remote Link™ to the panel. DB-9 connector. 397 RS-232 CABLE RS-232 cable for the XR500 Series Panels. DB-9 connector. 398 PRINTER CABLE Use with Model 462P to provide printer output from the panel. Replacement DB-9 data cable. 117 FAX: 800.743.5724 For use with: 462P Printer Interface Card on XR500 Series Panels. ORDER: 394 For use with: 462N Network Interface Card on XR Series Panels. ORDER: 397 For use with: XR500 Series Panels. ORDER: 398 For use with: 462P Printer. CUSTOMER SERVICE: 866.266.2826 118 INTRUSION DEVICES 399 PROGRAMMING HARNESS RS-232 DB-9 to 4-Wire connection to allow local uploading/downloading and flash updates. 400 USB FLASH MODULE The Model 400 USB Flash Module allows installers to easily field update firware for panels that would otherwise require the use of a computer and a Model 399 Programming Harness. It's equipped with a standard USB 2.0 compatible Type A female connector for interface to a USB Drive, a 4-pin connector between the 400 and the compatible panel, and an LED to indicate panel update status. Dimensions: 3 3/8" L x 7/8" W x 1/2" H 431 OUTPUT HARNESS 6-wire harness that allows connection of devices to the panel’s outputs. 572 INDICATOR LED The 572 is a remote indicator LED with a stainless steel plate. Mounts to any existing single gang box. (12 VDC) 3012 CLIP-ON TAMPER SWITCH The roller plunger contact switch is specially designed for use in security applications where size is a limiting factor. The contact switch is activated when the door opens, releasing the tension on the wheel plunger. ACCESSORY PACK BANK/VAULT DETECTORS ORDER: 399 For use with: XTL, XT and XR Series Panels. ORDER: 400 NEW For use with: XT Series, XTL Series, and CellComSL Series PANEL HARDWARE PACK The Panel Pack contains: two 3.3k EOL resistors with wire leads, one battery wire set, ten 1k EOL resistors one 1k 1/2 watt EOL resistor, one 4-position wire harness, one enclosure door key, and one wireless receiver antenna. PSD100 VAULT AUDIO DETECTOR CONTACTS For use with: XR Series Panels. 1076C SENTROL 3/4" DOOR CONTACT ORDER: 572 For use with: All DMP XT Series and XR Series Panels. ORDER: 3012 For use with: All DMP XT and XR Series Panels. For use with: All DMP XT and XR Series Panels. ORDER: PANEL PACK For use with: All DMP XT and XR Series Panels. The 1076C is designed specifically for use in the steel doors commonly found in commercial building applications, and features up to a 3/8" gap distance in steel doors. The unique housing design features a rugged unibody construction with flexible ribbed sides for quick, secure installation without gluing. 1085TW SENTROL SURFACE MOUNT CONTACT, WIDE GAP ORDER: 1076C For use with: All DMP XT and XR Series Panels. ORDER: 1085TW 1085TW-M (BROWN) The Sentrol 1085TW is ideal for residential and commercial applications where terminal connections are preferred. The unit features positive clamping terminals with anti-rotation lugs and captured screws with combination heads. For use with: All DMP XT and XR Series Panels. 2205A SENTROL DOOR CONTACT, OVERHEAD ORDER: 2205A The Sentrol 2205A includes a floor mounting contact in an extra-heavy, aluminum housing and an overhead door magnetic contact. The contact features a 3" gap, and a 3 foot stainless steel armored lead cable. The 2205-A has a N/C contact. For use with: All DMP XT and XR Series Panels. 2207A SENTROL DOOR CONTACT, HIGH SECURITY ORDER: 2207A The Sentrol 2207A includes a floor mounting contact in an extra-heavy, aluminum housing and an overhead door magnetic contact. The contact features a 3" gap, and a 3 foot stainless steel armored lead cable. The 2207A has a SPDT contact. For use with: All DMP XT and XR Series Panels. 2505A SENTROL INDUSTRIAL WIDE GAP CONTACT ORDER: 2505A Sentrol® industrial, wide gap, magnetic contact with armored cable. Normally Open/Normally Closed contact. For use with: All DMP XT and XR Series Panels. GP-23 CONTACT ORDER: GP-23 HSC BRACKET L-Bracket for mounting HSC-1 and HSC-2 High Security Contact Switches. FAX: 800.743.5724 For use with: XR Series Panels. For use with: All DMP XT and XR Series Panels. All screws are hidden and all wires can be hidden in this unique contact with a 1" gap. Wires can be brought in from the top, bottom, side, or behind! 119 ORDER: 3045 ORDER: PSD100 Self-contained, solid state device that detects intrusion by selectively detecting the sound of the forcible breaking and entering, while ignoring the ambient sounds of normal environment. ORDER: 431 ORDER: ACCESSORY PACK The technician’s accessory pack includes: 1 Panic Key label for DMP Keypads, 3 Model 300 4-wire Harnesses, 2 Model 330 4-wire Harnesses, 1 Model 300-7800-5 5-wire Harnesses, 1 Model 300-7800-12 12-wire Harnesses, 5 Model 302 2-pin Jumpers, 3 Model 305 Relays, 1 Model 431 XR Series Harness, 3 long plastic standoffs, 3 short plastic standoffs with screws, 8 1k EOL Resistors, and a DMP Screwdriver. 3045 SENTROL PANIC The Sentrol 3045 is a surface mount panic switch with terminals, SPST. It is activated when a user pulls the actuating lever. The 3045 can be wall mounted or placed out-of-sight but within reach for manual activation, such as under desks or counters in banks. The 3045 can also be used in residential installations where a panic switch is needed. For use with: All DMP XT Series and XR Series Panels. Color: White ORDER: HSC-BRACKET For use with: HSC switches. Color: Metallic CUSTOMER SERVICE: 866.266.2826 120 HSC-1 HIGH SECURITY CONTACT SWITCH The Potter High Security Contact Switch provides a triplebiased, Form C (SPDT) relay switch in the switch unit and a magnetic unit. Magnetic field tamper output for further protection. Narrow housing for mounting on door frames. (100 VDC Max.) MET-44WG-18 OVERHEAD CONTACT Small-sized, wide-gap overhead door contact with special push-pin to ensure the armored 18" cable never comes out of the switch side. The MET-44WG-18 from Tane features an adjustable L-Bracket that can be installed 10 different ways. Connect in the closed loop of an alarm system. ORDER: HSC-1 For use with: All DMP XT Series and XR Series Panels. Color: Metallic ORDER: MET-44WG-18 For use with: All DMP XT Series and XR Series Panels. Color: Metallic P2S-001 HIGH SECURITY SINGLE ZONE ORDER: P2S-001 PB-52TC PUSH-BUTTON REED WITH TERMINAL CONNECTS ORDER: PB-52TC The Tane PB-52TC is ideal for replacing old mechanical contacts. Great for door jams. Reed technology for long life. Includes screws and spacers. Connect in the closed loop of an alarm system. For use with: All DMP XT Series and XR Series Panels. Color: White SD-70 STEEL DOOR 3/4" RECESSED CONTACT ORDER: SD-70 SD-70/10 (PKG OF 10) Magnetic Sensor Magnetic contact with EOL Resistors. Normally Open/Normally Closed contact. The rugged, one-piece construction makes the SD-70 from Tane the perfect contact for standard and tight-fitting applications. Provides a sensitive, no-stick, UL rhodium reed. Thick, plastic shell to prevent crushing. Connect in the closed loop of an alarm system. SM-20WG 3" WIDE GAP CONTACT The Tane SM-20WG 3" Wide Gap Contact is idea for commercial or steel door installations. Connect in the closed loop of an alarm system. Dimensions: 4 1/8" x 5/8" x 5/8" STB-10 3/8" RECESSED CONTACT This stubby 3/8 inch wide gap from Tane is a true miniature size recess magnet, making it appropriate for tight fits. Connect the STB-10 from Tane in the closed loop of an alarm system. TANE 60 QUICK CONNECT CONTACT Slim style, quick installation contact: screw down or attach with Super Adhesive. Break-away features for tight fit. Eliminates need for 6' or 10' leads. Includes screws, Super Adhesive, breakaway mounting holes, and tape cover. Connect in the closed loop of an alarm system. Dimensions: 2" x 3/8" x 1/4" TANE WS1 WATER SENSOR The Tane WS1 Water Sensor is designed to respond to the presence of water and other liquids. Connect in the closed loop of an alarm system. TAKE ADVANTAGE OF DMP TECHNICAL TRAINING TO BECOME CONFIDENT AND COMPETENT IN YOUR ABILITY TO INSTALL DMP SYSTEMS. For use with: All DMP XT Series and XR Series Panels. Learn more. Install more. Make more. Call less! ORDER: SM-20WG For use with: All DMP XT Series and XR Series Panels. Color: White ORDER: STB-10 STB-10/10 (PKG OF 10) For use with: All DMP XT Series and XR Series Panels. Color: White ORDER: TANE 60 TANE 60/10 (PKG OF 10) WEB CLASSES: Web-based Training Classes can be taken at your convenience, 24/7, from anywhere you can access the Internet. It’s an efficient, cost-effective way to keep technicians up-to-date. Successfully completing a training program can earn Training Certificates and CEU credits. TECH TRAINING VIDEOS: Tech Training Videos provide detailed, single subject, step-by-step instructions you can use from your laptop, tablet or smartphone from your office or even while on the job site. From www.dmp.com click "Training" and then click"Tech Training Videos." ON-SITE TRAINING: Qualified dealers receive on-site technical training, led by a DMP product expert, for your installers and service technicians. They can gain valuable information that will build both their skills and your business. Training Certificates and CEU credits are available for select classes. For use with: XR Series Panels. ORDER: TANE WS1 For use with: All DMP XT Series and XR Series Panels. Color: Off-White CALL 1.800.641.4282 EXT. 179 Learn more about the training opportunities available for you. For full disclosure on DMP products and approval listings: www.dmp.com. 121 FAX: 800.743.5724 CUSTOMER SERVICE: 866.266.2826 122 082015 GLASS BREAK DETECTORS 5709C GLASSBREAK TESTER The 5709C-W is a hand held acoustic glassbreak tester that digitally generates the sound of breaking glass. When used with GE Security glassbreak detectors, the 5709C-W ensures the unit is installed within the specified range and is operating correctly. 5812A SHATTERPRO™ GLASSBREAK The Sentrol® 5812A acoustic glassbreak sensor provides greater false alarm immunity, faster surface mount installation, testing, and a hand-clap feature that lets end users confirm the sensor’s operational status. Includes tamper and latching LED. (9-16 VDC) 5820A SHATTERPRO™ GLASSBREAK The Sentrol® 5820A is designed for use when sensor appearance is a consideration. It can be recess-mounted directly into the wall or ceiling. (9-16 VDC) FG-730 FLEXGUARD GLASSBREAK The FlexGuard FG-730 detects glass breakage from distances up to 30’ (9 m). The dual Flex/Audio Technology provides excellent catch performance while virtually eliminating false alarms. Since 1984 ORDER: 5709C-W STB-10 For use with: All DMP XT Series and XR Series Panels. Color: Ivory ORDER: 5812A TANE ALARM AD For use with: All DMP XT Series and XR Series Panels. Color: Ivory ORDER: 5820A For use with: All DMP XT Series and XR Series Panels. Color: Ivory ORDER: FG-730 For use with: All DMP XT Series and XR Series Panels. Color: Ivory OVERSTOCK SPECIALS!!! LIMITED TIME ONLY TANE PB-52 WH 15% DISCOUNT MINIMUM ORDER QUANTITY IS 200 FM-102 BR 15% DISCOUNT PANIC/HOLDUP DETECTORS HUB-M HOLD-UP BUTTON The Potter HUB-M provides momentary or latching DPDT contacts for actuating surveillance cameras or other security applications. Dimensions: 2" x 2.3125" x 1" HUB-T HOLD-UP BUTTON The Potter HUB-T provides two sets of momentary or latching DPDT contacts for actuating surveillance cameras or other security applications, in addition to the hold-up signal. The two sets of contacts may be used independently of each other or they can be wired in series for additional protection against false alarms. Dimensions: 2.0625" x 3.4375" x 1.25" MINIMUM ORDER QUANTITY IS 200 ORDER: HUB-M For use with: All DMP XT Series and XR Series Panels. Color: Ivory ORDER: HUB-T For use with: All DMP XT Series and XR Series Panels.Color: Ivory Multi-Function CCTV Tester Tests PTZ Tests UTP Video Signal Analyzer LCD Screen Multi-Meter Function Note: Not all Tane products are stocked by DMP. 123 FAX: 800.743.5724 CUSTOMER SERVICE: 866.266.2826 124 INTRUSION DEVICES PANIC/HOLDUP DETECTORS CONT. RP-44 PUSH BUTTON Satin Stainless Steel Plate with One D.P.D.T. (Double Pole, Double Throw) Latching Switch, Contacts Rated 2 Amps. Allows for N/0 and N/C configurations. ORDER: RP-44 For use with: All DMP XT Series and XR Series Panels. PIR DETECTORS RX-40PI OPTEX 40’X 40’PIR WITH PET IMMUNITY ORDER: RX-40PI RX-40PI/10 (PKG OF 10) The Optex RX-40PI is designed to give high false alarm protection with tolerance to spot temperature changes from curtains to small to medium size animals. Divides detection zone into upper and lower areas and detect energy changes in both then couples them for extremely accurate detection. (17mA @ 12 VDC) 1100 SERIES PA-450PI TAKEX WIDE ANGLE WALL MOUNT PIR ORDER: PA-450PI Pet Immune up to 40lbs., 36’ x 84’ Wide angle, Fresnel lens, Pulse Count, Silent N/O or N/C selectable output, Tamper Circuit, LED on/off, Alarm Memory, 10 to 18VDC, UL Listed For use with: All DMP XT Series and XR Series Panels. The 1100D provides two-way, supervised communication using 900 MHz frequency hopping-spread-spectrum technology. The receiver and housing easily mount near the panel enclosure or in a remote location. CX-702 OPTEX 70’ X 70’ PIR ORDER: CX-702 1100DH WIRELESS HIGH-POWER RECEIVER 1100D WIRELESS RECEIVER For use with: All DMP XT Series and XR Series Panels. Color: White The 1100DH High Power Wireless Receiver provides additional transmit and receive amplification for improved performance at greater distance or harsh building environments. DX-40 OPTEX 40’ X 40’ PIR MICROWAVE DETECTOR ORDER: DX-40 1100DI WIRELESS RECEIVER The DX-40 improves security by supervising PIR and microwave signals and reporting either masking or microwave failure. Quad Zone Logic PIR technology provides Pet Immunity while still maintaining high catch. (12mA @ 12 VDC) For use with: All DMP XT Series and XR Series Panels. Color: White The 1100DI In-Line Wireless economical receiver provides the same basic features as the 1100D model but in a more compact unit. The compact design allows the receiver to be installed anywhere along the panel keypad bus, such as next to a keypad. DX-60 OPTEX 60’ X 60’ PIR MICROWAVE DETECTOR ORDER: DX-60 1100R WIRELESS REPEATER The CX-702 delivers superior stability and reliability for large commercial and institutional installations. The CX-702 unique Flip-Optics lens provides easy selection of a 70’ x 70’ or 150’ x 8’ pattern. (20 mA @ 12 VDC) The DX-60 improves security by supervising PIR and microwave signals and reporting either masking or microwave failure. Quad Zone Logic PIR technology. (12 VDC) EX-35T OPTEX 35’ X 35’ PIR The EX-35T combines a unique dual-purpose lens, patented multi-focus technology and selectable sensitivity to create four precise detection patterns. Provides easy selection of a 36’ x 36’ or 60’ x 6’ pattern. Also includes a tamper switch. (18mA @ 12 VDC) FX-360 OPTEX 360 PIR This slim detector is less than 1.5" tall x 4.75" diameter and provides 25’ - 40’ pattern on 8’ - 12’ ceilings. The FX-360 also includes False Alarm Reduction features that give it unbeatable detection performance and the most reliability in its class. (17mA @ 12 VDC) MX-40 OPTEX 40’X 40’PIR AND MICROWAVE DETECTOR The MX-40 combination detector incorporates a patented Quad Zone Logic which requires detection across multiple zones before an alarm is triggered. (12mA @ 12 VDC) 125 FAX: 800.743.5724 For use with: All DMP XT Series and XR Series Panels. Color: White For use with: All DMP XT Series and XR Series Panels. Color: White ORDER: EX-35T For use with: All DMP XT Series and XR Series Panels. Color: White ORDER: FX-360 For use with: All DMP XT Series and XR Series Panels. Color: White ORDER: MX-40 For use with: All DMP XT Series and XR Series Panels. Color: White The 1100R Wireless Repeater provides increased communication range and is the perfect solution for hard to reach areas. Up to eight repeaters can be installed on a wireless system. 1100X WIRELESS RECEIVER The 1100X provides two-way, supervised communication using 900 MHz frequency hopping-spread-spectrum technology. The receiver and housing easily mount near the panel enclosure or in a remote location. 1100XH WIRELESS HIGH-POWER RECEIVER The 1100XH High Power Wireless Receiver provides additional transmit and receive amplification for improved performance at greater distance or harsh building environments. 1101 UNIVERSAL TRANSMITTER The 1101 provides two internal magnetic reed switches and an on-board terminal block to allow for external contact wiring. Both sets of contacts, internal and external, can be programmed to operate at the same time allowing for two independent zones from one transmitter. Includes a 3V lithium battery. (CR123) ORDER: 1100D-W For use with: XT Series Panels. Color: White ORDER: 1100DH-W For use with: XT Series Panels. Color: White ORDER: 1100DI-W For use with: XT Series Panels. Color: White ORDER: 1100R-W For use with: 1100 Series Wireless Receivers. Color: White ORDER: 1100X-W For use with: XR Series Panels. Color: White ORDER: 1100XH-W For use with: XR Series Panels. Color: White ORDER: 1101-W For use with: 1100 Series Wireless. Color: White CUSTOMER SERVICE: 866.266.2826 126 TAKEX AD 1100 SERIES CONT. 1102 UNIVERSAL TRANSMITTER Typically used for door/window applications, the 1102 Universal Transmitter is a single-input, two-way wireless transmitter that provides an on-board terminal block to allow for external contact wiring of Normally Open or Normally Closed devices. Includes a 3V lithium battery. (CR123) 1103 UNIVERSAL TRANSMITTER This two-input transmitter is typically used in commercial burglary door/window applications. It includes an internal magnetic reed switch, an on-board terminal block for external contact wiring, and an end-of-line resistor. Both an internal case tamper switch and a wall tamper switch are provided. Includes a lithium battery and hardware pack. (CR123) 1106 UNIVERSAL TRANSMITTER The 1106 Universal Transmitter is less than half the size of 1101/1102 Series, providing for more mounting options and more discrete placement. This 2-input transmitter is typically used for door/window applications. The internal and external contacts can be programmed to operate at the same time, providing two independent zones from one transmitter. Includes a 3V lithium battery. (CR123) 1107 MICRO WINDOW TRANSMITTER This low-profile transmitter is typically used for window applications.It contains a single reed switch that detects a magnet mounted on the window. The 1107 provides survey capability to allow one person to confirm transmitter communication with the receiver before installation. A 3V coin cell battery powers the transmitter. (CR2430) 1114 WIRELESS ZONE EXPANDER ORDER: 1102-W For use with: 1100 Series Wireless. Color: White ORDER: 1103-W For use with: 1100 Series Wireless. Color: White ORDER: 1106-W For use with: 1100 Series Wireless. Color: White ORDER: 1107-W For use with: 1100 Series Wireless. Color: White ORDER: 1114-W The 1114 is a wireless zone expander with 4 Class B zones. Comes with in wall mount tamper magnet for added security. Includes a 3V lithium battery. (CR123) Can be powered by an optional Model 376 12VDC power supply. For use with: 1100 Series Wireless. Color: White 1116 WIRELESS RELAY OUTPUT ORDER: 1116-W The 1116 is a wireless relay output with a single Form C relay. Can be programmed for any panel output option. Includes a case tamper switch. Includes a 3V Lithium Battery. (CR123) Can be powered from an optional Model 376 12VDC power supply. For use with: 1100 Series Wireless. Color: White 1117R WIRELESS LED LIGHT ANNUNCIATOR ORDER: 1117R-W The 1117R is a wireless LED annunciator that provides a remote red LED for visual indication of system status. Can be programmed for any panel output option. Includes a case tamper switch. Includes a 3V Lithium Battery. (CR123) Can be powered from an optional Model 376 12VDC power supply. For use with: 1100 Series Wireless. Color: White and Black 1118R WIRELESS REMOTE PANIC INDICATOR LIGHT ORDER: 1118R-W The 1118R is a wireless remote indicator light that provides a visual panic alarm notification. Can be programmed for a panic alarm output option into the XR Series. Includes a case tamper switch. Includes a 3V Lithium Battery. (CR123) Can be powered from an optional Model 376 12VDC power supply. 127 FAX: 800.743.5724 For use with: 1100 Series Wireless. Color: White and Black CUSTOMER SERVICE: 866.266.2826 128 WIRELESS PRODUCTS 1100 SERIES CONT. 1119 WIRELESS DOOR SOUNDER The Model 1119 Wireless Door Sounder is a single-zone module equipped with a battery powered sounder. The zone input can be connected to a door contact, which when opened can trigger the sounder immediately without the need to receive an output command from the panel. The output allows the sounder to be silenced remotely from the panel as a standard output. Includes two 3V lithium batteries. (CR123) 1121 WIRELESS PIR The 1121 DMP Wireless PIR provides 90 Degree 50’ X 50’ ASIC based PIR coverage with Pet Immunity. Optional Ceiling or Wall mount bracket included. Includes one 3V lithium battery. (CR123) 1126 WIRELESS 360 CEILING MOUNT PIR The 1126R 360 Ceiling Mount PIR is a compact, low profile ceiling mount detector. Remote configuration from the panel allows selectable sensitivity, pulse count selection and walk test mode. Includes two 3V lithium batteries. (CR123) 1127C WALL MOUNT CURTAIN PIR The 1127C is an 1100 Series Wireless Wall Mount Curtain PIR. Detection area is 50' curtain using a fresnel lens. The unit is tampered and includes functionality to allow sensor configuration wirelessly from the panel. DMP Exclusive Features include Sensitivity, Pulse Count, Walk Test, & Disarm Disable. Includes two 3V lithium batteries. (CR123) 1127W WALL MOUNT WIDE ANGLE PIR WITH PET IMMUNITY 1139 WIRELESS BILL TRAP ORDER: 1119-W For use with: 1100 Series Wireless. Color: White 1141 WIRELESS WALL BUTTON ORDER: 1121-W For use with: 1100 Series Wireless. Color: White ORDER: 1126R-W For use with: 1100 Series Wireless. ORDER: 1127C-W For use with: 1100 Series Wireless. For use with: 1100 Series Wireless. 1129 WIRELESS GLASSBREAK ORDER: 1129-W 1131 WIRELESS RECESSED CONTACT The 1131 is a wireless recessed contact with a 3/8" to 1" gap. Includes one 3V lithium battery. 1135 WIRELESS SIREN The 1135 Wireless Siren Series makes it possible to quickly and easily place one or more sirens as part of an installation. The 1135 includes a cover tamper and survey LED, and comes with batteries. The 1135 has a volume of 100 dB, while the 1135dB offers 110 dB. 1137 WIRELESS LED EMERGENCY LIGHT The 1137 Wireless LED Light can be activated from a panel output or when an alarm is triggered with the panel bell. The 1137 can provide emergency indoor path lighting even with AC power is lost or during any other type of emergency. It can be installed virtually anywhere, and their thin design complements any decor. The 1137 uses 2 AA Lithium batteries that are designed to be replaced by the consumer. 129 FAX: 800.743.5724 The 1141 Wall Button is a one-button wireless transmitter designed to be wall-mounted. The 1141 features a waterresistant button (when installed using the double-sided tape mounting procedure) with a Status LED to provide visual indication that a message has been transmitted and received by the panel. The wall button can be used as a panic button, and, when programmed in output options, as a garage door opener, light switch, door release, or an arming or disarming button. The 1141 operates using the supplied 3 Vdc Lithium batteries. Dimensions: 3" H x 2.5" W x .5" D 1142 WIRELESS 2-BUTTON HOLD UP TRANSMITTER For use with: 1100 Series Wireless. Color: White ORDER: 1135-W 1135DB-W For use with: XTL, XT Series, and XR Series Panels. Color: White ORDER: 1137-W NEW For use with: 1100 Wireless Series ORDER: 1141-W For use with: XTL, XT, XR Series Panels. Color: White For use with: 1100 Series Wireless. Color: White and Black 1142BC WIRELESS 2-BUTTON HOLD UP TRANSMITTER WITH BELT CLIP ORDER: 1142BC-W 1142BC-B The 1142BC Two-Button Hold Up Transmitter with Belt Clip is specifically designed to be worn on a belt when the belt clip is installed. Programmable LED feedback lets you know when Panic alarm has been sent. Includes one 3V lithium battery. (CR2032) The 1145-4-B is a Four-Button Key Fob transmitter that is portable, water resistant, and designed to be clipped to a keychain or DMP 332 lanyard. The 1145-4-B provides fourbutton operation. Includes one coin battery. (CR2032) The 1145-2-B is a Two-Button Key Fob transmitter that is portable, water resistant, and designed to be clipped to a keychain or DMP 332 lanyard. The 1145-2-B provides twobutton operation. Includes one coin battery. (CR2032) 1145-1-B WIRELESS KEY FOB The 1145-1-B is a One-Button Key Fob transmitter that is portable, water resistant, and designed to be clipped to a keychain or DMP 332 lanyard. Includes one coin battery. (CR2032) ORDER: 1131-W For use with: XTL, XT, XR Series Panels. Color: White The 1142 Two Button Hold-up Transmitter is specifically designed for installation under the counter. Programmable LED feedback lets you know when Panic alarm has been sent. Includes one 3V lithium battery. (CR2032) 1145-2-B WIRELESS KEY FOB For use with: 1100 Series Wireless. Color: White ORDER: 1139-I ORDER: 1142-W 1142-B 1145-4-B WIRELESS KEY FOB ORDER: 1127W-W The 1127W is an 1100 Series Wireless Wall Mount Wide Angle PIR. It is Pet Immune up to 40lbs. Detection area is 36' x 84' angle using a fresnel lens. The unit is tampered and includes functionality to allow sensor configuration wirelessly from the panel. DMP Exclusive Features include Sensitivity, Pulse Count, Walk Test, & Disarm Disable. Includes two 3V lithium batteries. (CR123) The 1129 Glassbreak wireless sensor is omni-directional, providing 360° detection coverage of framed glass mounted in an outside wall. Mount the 1129 Glassbreak on the ceiling or an opposing wall for maximum flexibility and coverage. Includes one 3V lithium battery. (CR123) The 1139 Wireless Bill Trap has a built-in switch that transmits an alarm to the receiver when the cashier removes the trapped bill. An optional Retard Delay feature allows the bill to be returned without initiating an alarm. Includes two coin cell batteries (CR2450). 1145-1-BP WIRELESS KEY FOB The 1145-1-BP is a One-Button Key Fob transmitter that includes a built-in proximity credential for access control. This accessory now meets two requirements - controlling the system for such functions as arming, disarming or panic, as well as being able to arm or disarm via an access control system 1148-G WIRELESS PERSONAL PENDANT The 1148 Personal Pendant is a one-button, wireless emergency transmitter designed to be worn as a wristband or on a break-away lanyard. The 1148 may be used to activate an event at the receiver. The 1148 features a permanently sealed, water-resistant design and includes a Status LED to provide visual indication that a message has been transmitted and received by the receiver. The 1148 operates using a pre-installed non-removable battery. For use with: 1100 Series Wireless. Color: White and Black ORDER: 1145-4-B For use with: 1100 Series Wireless. Color: Black ORDER: 1145-2-B For use with: 1100 Series Wireless. Color: Black ORDER: 1145-1-B For use with: 1100 Series Wireless. Color: Black ORDER: 1145-1-BP For use with: 1100 Series Wireless. Color: Black ORDER: 1148-G NEW For use with: 1100 Series Wireless. Color: Black CUSTOMER SERVICE: 866.266.2826 130 WIRELESS PRODUCTS 1100 SERIES CONT. 1161 WIRELESS DETECTOR CR123 REPLACEMENT BATTERY ORDER: 1161-W The Model 1161 Smoke Detector with Sounder is a wireless detector used with the 1100D and 1100X Series Wireless Receiver. Includes two 3V lithium batteries. (CR123-FIRE) For use with: 1100 Series Wireless. Color: White 1162 WIRELESS DETECTOR ORDER: 1162-W The Model 1162 Smoke/Heat Detector with Sounder is a wireless detector used with the 1100D and 1100X Series Wireless Receivers. Featuring a sounder and built-in fixed and rate-of-rise heat detector. Includes two 3V lithium batteries. (CR123-FIRE) 1164 WIRELESS SMOKE DETECTOR WITH SYNCHRONIZED SOUNDER For use with: 1100 Series Wireless. Color: White ORDER: 1164-W NEW The DMP 1164 Smoke Detector is a wireless device with integrated synchronized sounder. In installations with multiple smoke detectors, when one 1164 sounds, it signals the panel to command all 1164s to sound. Any fire zone tripped on the panel will cause the sounders to initiate. The panel also triggers any other wired strobes and strobe horns. The cadence is dictated by the panel, synchronizing the alarm tones of all wired and wireless devices. The 1164 uses the robust and experienced 900 MHz 2-Way Wireless technology from DMP that has been approved for Commercial Fire applications for several years. For use with: 1100 Series Wireless. Color: White 1165 COMMERCIAL SMOKE DETECTOR ORDER: 1165-W The Model 1165 Smoke Detector is a commercial wireless detector used with the 1100X Wireless System. Features remote maintenance reporting. Includes two 3V lithium batteries. (CR123-FIRE) ORDER: CR123/8 3V Lithium battery. 8 pack. For use with: 1100 Series Wireless. CR123-FIRE REPLACEMENT BATTERY ORDER: CR123-FIRE/8 Replacement 3V Lithium battery. Pack of 8. For use with: All 1100 Series Fire Products. CR2032 REPLACEMENT BATTERY ORDER: CR2032/10 (PKG OF 10) Single 3V replacement lithium coin cell battery. Package of 10. For use with: 1145 Series Wireless Key Fobs. CR2430 REPLACEMENT BATTERY ORDER: CR2430/10 (PKG OF 10) Single 3V replacement lithium coin cell battery. Package of 10. For use with: 1107 Wireless Transmitters. CR2450 REPLACEMENT BATTERY ORDER: CR2450/10 (PKG OF 10) Single 3V replacement lithium coin cell battery. Package of 10. For use with: 1100 Series Wireless. For Commercial use with XR Series. Color: White For use with: 1139. CR17450 BATTERY PACK ORDER: CR17450 Replacement 3V Lithium Battery Pack. For use with: 1126 Series Wireless PIRs. ES531 OUTDOOR ENCLOSURE 1165H COMMERCIAL SMOKE AND HEAT DETECTOR ORDER: 1165H-W The Model 1165H Commercial Smoke/Heat Detector is a wireless detector used with the 1100X Wireless System. Featuring a built-in fixed and rate-of-rise heat detector and remote maintenance reporting. Includes two 3V lithium batteries. (CR123-FIRE) For use with: 1100 Series Wireless. For Commercial use with XR Series. Color: White 1165HS COMMERCIAL SMOKE AND HEAT DETECTOR WITH SOUNDER ORDER: 1165HS-W The Model 1165HS Commercial Smoke/Heat Detector with Sounder is a wireless detector used with the 1100X Wireless System. Featuring a sounder, built-in fixed and rate-of-rise heat detector and remote maintenance reporting. Includes two 3V lithium batteries. (CR123-FIRE) For use with: 1100 Series Wireless. For Commercial use with XR Series. Color: White ORDER: ES531 Outdoor enclosure. Dimensions: 4.53" x 2.56" x 1.57" For use with: 1100DI Receivers; 1101, 1102 and 1103 Transmitters; 711 Module. ES532 OUTDOOR ENCLOSURE ORDER: ES532 Outdoor enclosure. Holds 2 1101 Style transmitters. Dimensions: 6.73" x 4.76" x 2.17" For use with: 1101, 1102 and 1103 Transmitters. Z-WAVE® Z-WAVE DOOR LOCK The 1183-135F is a fixed temperature detector that reacts to heat by responding to the fixed 135° temperature setting. When activated, an alarm is sent to the control panel. The 1183-135F model has a black dot on the heat collector fin for identification. For use with: 1100 Series Wireless.Color: White Z-Wave Kwikset SmartCode 5-Button Electronic UL Listed Deadbolt featuring SmartKey with BumpGuard technology. Remote locking and unlocking - a motor driven deadbolt allows for true remote control and real-time status. Monitor and control door locks from anywhere via Internet or mobile phone. Compatible with MyAccess and Virtual Keypad App. Available in Polished Brass, Satin Nickel, and Venetian Bronze. 1183-135R WIRELESS HEAT DETECTOR ORDER: 1183-135R Z-WAVE DOOR LOCK 1183-135F WIRELESS HEAT DETECTOR The 1183-135R model is a combination rate-of-rise and fixed temperature detector that detects heat quickly by responding to a rapid temperature increase or a fixed 135° temperature setting. The element responds to a rapid rise in temperature and sends an alarm to the control panel when the ceiling temperature increases at a minimum rate of 15°F per minute. An alarm is also sent to the panel if the ceiling temperature reaches the fixed 135° setting if the rate-of-rise is not exceeded. 1184 CARBON MONOXIDE DETECTOR The 1184 is a 3V battery powered wireless carbon monoxide (CO) detetor that provides early warning when the electrochemical sensing technology measures carbon monoxide levels in the air. The detector consists of an eltrochemical carbon monoxide sensor assembly coupled with an 1100 Serieswireless transmitter. The transmitter can send alarm, trouble, tamper and low battery condition messages to the alarm panel. 131 FAX: 800.743.5724 ORDER: 1183-135F For use with: 1100 Series Wireless. Color: White ORDER: 1184-W For use with: 1100 Series Wireless. Color: White Z-Wave Kwikset SmartCode 10-Button Electronic UL Listed Deadbolt featuring SmartKey with BumpGuard technology. Remote locking and unlocking - a motor driven deadbolt allows for true remote control and real-time status. Monitor and control door locks from anywhere via Internet or mobile phone. Compatible with MyAccess and Virtual Keypad App. Available in Polished Brass, Satin Nickel, and Venetian Bronze. Z-WAVE DOOR LOCK Z-Wave Kwikset SmartCode Touchscreen Electronic UL Listed Deadbolt featuring SmartKey with BumpGuard technology and Patent-Pending Secure Screen technology to prevent fingerprints from giving away user code information. Remote locking and unlocking - a motor driven deadbolt allows for true remote control and real-time status. Monitor and control door locks from anywhere via Internet or mobile phone. Compatible with MyAccess and Virtual Keypad App. Available in Polished Brass, Satin Nickel, and Venetian Bronze. ORDER: Z-99100-004 Z-99100-005 Z-99100-006 For use with: XT, XTL, and XR150|XR550 Series Panels with the 738Z Module. NEW ORDER: Z-99140-001 Z-99140-002 Z-99140-003 For use with: XT, XTL, and XR150|XR550 Series Panels with the 738Z Module. NEW ORDER: Z-99160-001 Z-99160-002 Z-99160-003 For use with: XT, XTL, and XR150|XR550 Series Panels with the 738Z Module. CUSTOMER SERVICE: 866.266.2826 132 KWIKSET AD Z-WAVE® CONT. Z-WAVE DOOR LOCK Z-Wave Kwikset Traditional Round Electronic UL Listed Deadbolt featuring SmartKey with BumpGuard technology. Great low-cost addition for secondary doors or where a keypad is not required. Remote locking and unlocking - a motor driven deadbolt allows for true remote control and real-time status. Monitor and control door locks from anywhere via Internet or mobile phone. Compatible with MyAccess and Virtual Keypad App. Available in Polished Brass, Satin Nickel, and Venetian Bronze. Z-WAVE GARAGE DOOR CONTROLLER The Z-GD00Z-4 Z-Wave Garage Door Controller is compatible with virtually any automatic garage door opener. Installers only have to 'pair' the unit into the Gateway of the current garage door opener to provide simple wireless control. Combine with Z-wave lights, locks, and thermostats for total home or small business control. Compatible with the Virtual Keypad App. DEMO KWIKSET DOOR LOCK DESK STAND Display Desk Stand for use with Z-wave compatible Kwikset Locks. Z-WAVE THERMOSTAT The Z-5010T thermostat is fully programmable, provides complete Z-Wave communication, and can even operate as a Z-Wave repeater. Its battery-only operation means it does not require the 5th wire during installation making this a quick install for your technicians so they can spend more time showing the end-user how the thermostat works. Z-WAVE LAMP MODULE WITH DIMMER The Lamp Module enables remote control of on/off/dim functions for incandescent lighting via the DMP alarm system. ORDER: Z-99160-001 Z-99160-002 Z-99160-003 NEW For use with: XT, XTL, and XR150|XR550 Series Panels with the 738Z Module. ORDER: Z-GD00Z-4 NEW ✓ Increase RMR ✓ Increase system usage ✓ Increase customer retention ✓ Provide the total security solution For use with: 738Z Module. ORDER: Z-99100-STAND For use with: XT, XTL, and XR150|XR550 Series Panels with the 738Z Module. ORDER: Z-5010T NEW For use with: XT, XTL, and XR150|XR550 Series Panels with the 738Z Module. ORDER: Z-45602 For use with: XT, XTL, and XR Series Panels with the 738Z Module Z-WAVE FLUORESCENT LIGHT & APPLIANCE MODULE ORDER: Z-45603 The Light & Appliance Module enables remote control of on/off functions for fluorescent lights, lamps and small appliances via the DMP alarm system. For use with: XT, XTL, and XR Series Panels with the 738Z Module Z-WAVE IN-WALL TOGGLE STYLE ON/OFF RELAY SWITCH ORDER: Z-45740 NEW This On/Off switch replaces your current light switch and uses the existing wiring to put Z-Wave in control of your overhead lighting. The toggle switch wirelessly enables control of direct wire incandescent, LED, xenon, halogen and fluorescent lighting. For use with: XT, XTL, and XR Series Panels with the 738Z Module Z-WAVE TOGGLE STYLE AUXILARY SWITCH ORDER: Z-45741 This Z-Wave compatible auxiliary light switch replaces your current light switch and uses the existing wiring to put Z-Wave in control of your overhead lighting. The toggle switch wirelessly enables control of lighting in 2-way, 3-way, or 4-way wiring configurations. #1 RESIDENTIAL LOCK BRAND WITH Z-WAVE® NEW Innovative Security: Easy Integration: Keyless Entry: • Full 128-Bit Encryption Security • • No keys to misplace, lose, or hide • Motorized Deadbolt— enables true remote locking & unlocking • Replaces Existing Deadbolt with just a screwdriver • Lock/unlock doors via Smartphone or Internet connection • BumpGuard™ Protection with SmartKey™ technology • 4 AA Batteries (no hard wiring)— batteries last for approximately 1 year • Multiple Unique User Codes – up to 30 Wireless Protocol For use with: XT, XTL, and XR Series Panels with the 738Z Module For more information: www.kwikset.com/wirelesslocks 133 FAX: 800.743.5724 CUSTOMER SERVICE: 866.266.2826 1225 134 CENT AL STATION PRODUCTS Z-WAVE® CONT. Z-WAVE IN-WALL DIMMER SWITCH This dimmer switch enables wireless control of on/off and dim functions of hard-wired CFL/LED and Incandescent lighting. The switch replaces an existing light switch, uses existing wiring, and provides Z-Wave wireless and in-wall control of overhead lighting. The dimmer feature allows customers to customize the lighting output and create the perfect ambiance for any room in their home or business. Z-WAVE LED LIGHT BULB The Z-LB60Z-1 Z-Wave LED Light Bulb screws into any normal light bulb socket, making it the fastest and most efficient way to take wireless control of lighting in your home or small business. The Z-LB60Z-1 consumes only 9 watts of energy and is also dimmable to 100 levels. Pair with Z-Wave lights, locks, and thermostats to take total control of your home or small business. Compatible with the Virtual Keypad App. RECEIVER PRODUCTS ORDER: Z-45742 NEW For use with: XT, XTL, and XR Series Panels with the 738Z Module ORDER: Z-LB60Z-1 NEW For use with: 738Z Module INDOOR/OUTDOOR BULLET CAMERA Includes: • SCS-RACK with multibus cage and fan, and membrane keypad with LCD display. • SCS-104 Line Cards • SCS-110 Modem Power Card • SCS-120 Multibus Power Supply Card • SCS-130 Transformer Card • SCS-150 Main Processor Card • SCS-203 Convenience Panel • SCS-208 Power Cord SCS-104 LINE CARD CAMERAS AND ACCESSORIES The V-4010B-1 is an Indoor/Outdoor Bullet Camera with 1.3 megapixel resolution and IR LEDs for no/low light imaging at up to 30 meters. Dimensions: 3.0" H x 2.4" W x 5.5" D SCS-1R NETWORK ENABLED RECEIVER The SCS-1R Security Control Receiver is an advanced, highly reliable central station receiver that can monitor dialer, LAN/ WAN or Internet accounts for alarm, trouble, user, and system reports. Full English readout on all alarm messages and optional output to a host computer. ORDER: V-4010B-1 NEW For use with: Stand-alone. The SCS-104 provides four digital dialer (DD) lines and a network connection for communication to DMP panels. Each card includes one shielded eight-pin modular connector (J1) for the digital data network connection. This allows the SCS-1R Receiver to accept alarm and system messages over a network from DMP panels. Each card also includes a non-shielded eight-pin modular connector (J3) that supports up to four digital dialer lines, when connected to a standard RJ61 jack. SCS-105 SDLC SINGLE LINE SERVICE RECEIVER INDOOR CUBE PIR CAMERA The V-4020C-1 is an Indoor Cube PIR Camera with 1.3 megapixel resolutioon, PIR PIR detection and IR LEDs for no/low light imaging at up to 10 meters. Dimensions: 5.2" H x 2.8" W x 3.6" D HD IP MOTORIZED INDOOR CAMERA The V-4030PT-1 is a HD IP Motorized Indoor Camera with 1.0 megapixel resolution, PIR detection and IR LEDs for no/low light imaging at up to 10 meters. The Motorized Indoor Camera also features a pan/tilt rotation. Dimensions: 5.51" H x 4.49" W INDOOR/OUTDOOR FIXED DOME INFRARED CAMERA The V-4050D-1 is an Indoor/Outdoor Fixed Dome Infrared Camera with 1.3 megapixel resolution and IR LEDs for no/low light imaging at up to 30 meters. Dimensions: 4.4" Dia x 3.2"H WIRELESS ACCESS POINT This High-speed Wireless Access Point comes pre-configured for easy-set up with SecureCom Video cameras. It offers 300Mbps wireless speed, supports multiple operation modes, supports power over Ethernet (PoE). WPA and WPA2. WPS encrypted connection can be set up with a single-button push. Up to 100-foot range. ORDER: V-4020C-1 NEW For use with: Stand-alone. ORDER: V-4030PT-1 NEW ORDER: SCS-104 For use with: SCS-1R Security Control Receiver. ORDER: SCS-105 Provides one line of dialer or multiplex operation. Capable of proprietary receiver or remote uploading/downloading operations. Includes serial cable for connection to IBM or compatible computer using DMP Remote Link™ or System Link™ software. For use with: Stand-alone IBM compatible computers running DMP Remote Link™ or System Link™ software. SCS-110 MODEM POWER CARD ORDER: SCS-110 Provides power to a maximum of five line cards through the receiver’s backplane connectors. No additional cables are needed. For use with: SCS-1R Security Control Receiver. For use with: Stand-alone. SCS-120 MULTIBUS POWER CARD ORDER: V-4050D-1 NEW For use with: Stand-alone. Provides power to the main processor card (SCS-1062) through the receiver’s backplane connectors. Monitors the condition of the processor card and the voltage output of the SCS-110 Modem Power Supply Card as well as its own internal voltages. No additional cables are needed. SCS-130 TRANSFORMER CARD ORDER: V-IP1006RR NEW Powers the modem and multibus power supply cards. Terminals are provided for connecting 120 VAC to the system and a power cord is provided for connecting to the multibus rack cooling fan. ORDER: SCS-120 For use with: SCS-1R Security Control Receiver. ORDER: SCS-130 For use with: SCS-1R Security Control Receiver. For use with: V-4050D-1, V-4020C-1, V4010B-1, V-4030PT-1 SCS-150 MAIN PROCESSOR CARD The SCS-150 provides a battery-backed 5000 event buffer, and the fast transmission speeds and high data integrity of the Serial 3 communications format. ORDER: SCS-150 SCS-150/CONVERT SCS-150/UPDATE For use with: SCS-1R Security Control Receiver. 135 FAX: 800.743.5724 CUSTOMER SERVICE: 866.266.2826 136 SOFTWA E PRODUCTS RECEIVER PRODUCTS SCS1R-SPARES Spare board kit. Includes: SCS-150, SCS-104, SCS-110, SCS-120, SCS-130, and Keypad PCB. SCS-203 CONVENIENCE PANEL Mounts on the back of the receiver and provides three cable connectors for attaching a local printer and host computer. Includes necessary cables for connecting to the receiver components. RECEIVER PRODUCTS CONT. ORDER: SCS1R-SPARES For use with: SCS-1R Security Control Receiver. 388 PRINTER CABLE ORDER: 388 10 foot printer cable used for connection between the SCS-1R Central Station Receiver and SG-DPU-414 Printer. Discontinue 08/01/13 395 SCS-105 DATA CABLE ORDER: SCS-203 ORDER: 395 This data cable is used to connect a PC to the SCS-105 Receiver. For use with: SCS-105 SDLC Single Line Receiver. For use with: SCS-1R Security Control Receiver and SCS-150 Processor Board. SCS-VR SCS-204 HOST CABLE Allows you to connect the receiver host output to the Remote Link™ computer. The SCS-204 is 25 ft. long with a DB-25 male and DB-25 female connector on each end. SCS-206 KEYPAD AND LINECARD CABLES Connects the keypad and the linecard with the SCS-150 Processor Board. ORDER: SCS-204 For use with: SCS-1R Security Control Receiver. The SCS-VR Virtual Receiver is a software only receiver solution that can run on a single server, or multiple servers acting as a single server. Scalable from one to hundreds of thousands of network control panels. It delivers all of the unique DMP advantages, including improved panel to receiver path redundancy as well as both inbound and outbound TCP network connections to automation, all with no proprietary hardware. Annual Supprt available for all account levels. Connects the various system voltages between the transformer card and the SCS-120 Multibus Power Supply Card. For use with: SCS-150 Main Processor Card. The SCS-186T printer’s small footprint makes it ideal for use in your system configuration. The operator panel control of character sets, form length, and other frequently used functions makes the SCS-186T quite easy to use. The printer also has a “lockout" feature to prevent unauthorized setting changes. (Non-UL) SCS-RACK Enclosure for SCS-1R with multibus cage and fan, and membrane keypad with LCD display. Includes everything you need to update an existing SCS-1 Receiver to SCS1R. Does not include SCS-101 line cards. ORDER: SCS-208 For use with: SCS-1R Security Control Receiver. ORDER: SCS-186T For use with: SCS-1R Security Control Receiver or as an Upgrade Kit to an SCS-1 Receiver. ORDER: SCS-RACK For use with: SCS-1R Security Control Receiver or as an Upgrade Kit to an SCS-1 Receiver. For use with: System Link™ and Remote Link™ Software. End-user management software allows you to set up account files, authorize users, and connect to panels to maintain User Codes, Schedules, Holiday Dates, and Profiles. LINK SERVER Link Server allows multiple Remote Link computers to access a Remote Link database located on a network server. Link Server provides a server database and is designed for applications where more than three computers must perform extensive database access operations at the same time. Panel management software allows you to maintain subscriber accounts, trap panels, and change programming—all from a remote computer, such as a laptop. The many functions and capabilities of Remote Link provide you with a software program that allows you to effortlessly maintain subscriber accounts. FAX: 800.743.5724 ORDER: 1301I 1301P This innovative proximity reader enables you to significantly increase the efficiency of entering user codes when using Remote Link™ and System Link™ Management Software. By providing simple Proximity Card enrollment intto system software, the Admin Reader is beneficial for every system administrator. 1301I is for iClass Series only. REMOTE LINK™ 137 500 2500 5000 10000 20000 5GRP/UPG SOFTWARE SYSTEM LINK™ SCS-186T PRINTER ORDER: SCS-VR SCS-VR SCS-VR SCS-VR SCS-VR SCS-VR ORDER: SCS-206 1301 USB COMPUTER PROXIMITY READER SCS-208 POWER CORD For use with: SG-DPU-414 Printer. ORDER: SYSTEM LINK For use with: All DMP panels new and old. Single Workstation License ORDER:LINK SERVER For use with: All DMP panels new and old. Single Workstation License ORDER: REMOTE LINK For use with: All DMP panels new and old. Single Workstation License CUSTOMER SERVICE: 866.266.2826 138 COMMUNICATION PRODUCTS SOFTWARE CONT. ACCOUNT GROUPS MODULE The Account Groups module provides you the time saving ability to assign, update, change, or delete user codes on multiple panels at the same time. Using the Account Groups module, you can group panels together under one name. Associate the groups by location, business, or other logical grouping. NETWORK COMMUNICATION ORDER: ACCOUNT ACCOUNT ACCOUNT ACCOUNT ACCOUNT ACCOUNT ACCOUNT ACCOUNT GROUPS GROUPS GROUPS GROUPS GROUPS GROUPS GROUPS GROUPS 10 (1-10) 50 (11-50) 100 (51-100) 500 (101-500) 1000 (501-1000) 2500 (1001-2500) 5000 (2501-5000) ADD Software license supports up to 3 workstations. (additional single workstation license) For use with: System Link™ and Remote Link™ . ADVANCED REPORTING MODULE Software license supports up to 3 workstations. ORDER: ADVANCED ADVANCED ADVANCED ADVANCED ADVANCED ADVANCED ADVANCED ADVANCED 10 (1-10) 50 (11-50) 100 (51-100) 500 (101-500) 1000 (501-1000) 2500 (1001-2500) 5000 (2501-5000) ADD (additional single workstation license) For use with: System Link™ and Remote Link™. ALARM MONITORING MODULE ORDER: ALRM MON ALRM MON ALRM MON ALRM MON ALRM MON ALRM MON ALRM MON ALRM MON 10 (1-10) 50 (11-50) 100 (51-100) 500 (101-500) 1000 (501-1000) 2500 (1001-2500) 5000 (2501-5000) ADD ORDER: COMMAND COMMAND COMMAND COMMAND COMMAND COMMAND COMMAND COMMAND 10 (1-10) 50 (11-50) 100 (51-100) 500 (101-500) 1000 (501-1000) 2500 (1001-2500) 5000 (2501-5000) ADD Provides powerful filtering capabilities to create specific reports for your needs. You can create reports using the panel’s event buffer or by using the PC Log Reports feature. Additionally, you may connect to the Advanced Reporting Module through a direct connection or network connection. Installs with Remote Link or System Link to add alarm messaging, and acknowledgement for small proprietary central stations, guard stations, or campuses, with or without the ability to remotely program the panels. Software license supports up to 3 workstations. (additional single work station license) For use with: System Link™ and Remote Link™. COMMAND CENTER MODULE Enables you to visually monitor alarm activity for multiple subscriber accounts using an SCS-1R Receiver, SCS-105 Receiver, or an Ethernet host monitoring network connection. The Command Center is an add-on module to your Remote Link™ or System Link™ program. Software license supports up to 3 workstations. (additional single work station license) For use with: System Link™ and Remote Link™. SQL DATABASE MODULE The DMP SQL Module allows large corporate users to configure an ODBC connection to an existing Microsoft SQL server installation they already have in place. It allows for up to 5 seats/licenses. If more than 5 seats are required, the SQL Module ADD offers additional single licenses that adds onto your Remote Link and System Link programs. SCS-CTM Table management software ensures no check-ins are lost when an SCS-101 line card is replaced or to mirror the primary receiver SCS-101 Check-in table for use on a secondary receiver SCS-101. ORDER: SQL MODULE SQL MODULE ADD For use with: System Link™ and Remote Link™. ICOMSL UNIVERSAL NETWORK COMMUNICATOR The iComSL Network Alarm Communicator provides a fully supervised alarm communication path over a network connection. With this simple communication add-on, almost every panel can take advantage of revenue-building remote system management and control features. Arming and disarming come standard, along with the ability to view cameras. Program your own account number to easily work around locked panels. For use with: Burglary Alarm Control Panels. ICOMSL UNIVERSAL NETWORK COMMUNICATOR WITH Z-WAVE ORDER: ICOMSLZ The iComSLZ Network Alarm Communicator provides a fully supervised alarm communication path over a network connection. With this simple communication add-on, almost every panel can take advantage of revenue-building remote system management and control features. Arming and disarming come standard, along with the ability to view cameras. Program your own account number to easily work around locked panels. Add Z-Wave control of lights, locks, garage doors, and thermostats with the iComSLZ For use with: Burglary Alarm Control Panels. ICOMSLF UNIVERSAL FIRE ALARM COMMUNICATOR ORDER: ICOMSLF The iComSLF Network Fire Alarm Communicator provides a fully supervised alarm communication path over network or internet connections. The iComSLFmeets the NFPA 72 Standard for commercial fire applications and provides alarm dealers with a fire solution to update existing customer panels or takeovers. Dealers don't have to worry about lock-out codes; they can just add the DMP iComSLF unit onto ANY existing 12 - 24v dialer installations via Contact ID or Zone inputs. For use with: SCS-101 and SCS-104 Line Cards. Single Workstation License NEW NEW For use with: Fire Alarm Control Panels. CELLULAR COMMUNICATION 263C CELLULAR COMMUNICATOR The 263C CDMA Cellular Communicator provides wireless communication for the XT Series Panels. The 263C contains an on-board CDMA communications module that allows alarms messages to be communicated to an SCS-1R or SCS-VR receiver over the CDMA network. Ready for activation with SecureCom Wireless, LLC with the MEID number - no SIM card required. 263C-381-2. Includes Model 381-2 18" Coax Cable. 263H CELLULAR COMMUNICATOR ORDER: SCS-CTM NEW ORDER: ICOMSL The 263H provides wireless communication for the XT Series Panels. The 263H contains an on-board HSPA+ communications module that allows alarm messages to be communicated to an SCS-1R or SCS-VR receiver over the network. The 263H ships with a SIM card ready for activation with SecureCom Wireless, LLC. Includes Model 381-2 18" Coax Cable. ORDER: 263C 263C/381-2 For use with: XT & XR150|XR550 Series Panels. ORDER: 263H 263HCAN 263H/381-2 For use with: XT & XR150|XR550 Series panels. ACCESSORIES SD205 ETHERNET SWITCH Ethernet switch with 5 10Base-T ports used to integrate 10Mbps Ethernet and 100Mbps Fast Ethernet devices. Each port can independently negotiate up to 200Mbps of bandwith for best speed and half- or full-duplex mode. 139 FAX: 800.743.5724 ORDER: SD205 For use with: All DMP XR Series panels. CUSTOMER SERVICE: 866.266.2826 140 CELLULA PRODUCTS CELLCOMSL DMP is a family-owned manufacturer of electronic burg/fire/access products. Since 1975 we have designed, built, distributed & supported those products from our headquarters in Springfield, MO. We sell directly to preferred alarm companies who are passionate about providing life-safety and peace-of-mind and focused on recurring monthly revenue. This is our only business. TEN THINGS TO CONSIDER CELLCOMSLC UNIVERSAL ALARM COMMUNICATOR CELLCOMSLC The CellComSLC Cellular Alarm Communicator provides a fully supervised alarm communication path over the CDMA network. With this simple communication add-on, almost every panel can take advantage of revenue-building remote system management and control features. Arming & disarming come standard along with the ability to view up to six cameras. Program your own account number to easily work around locked panels. For use with: Burglary Alarm Control Panels. CELLCOMSLCZ UNIVERSAL ALARM COMMUNICATOR WITH Z-WAVE CELLCOMSLCZ The CellComSLCZ Cellular Alarm Communicator provides a fully supervised alarm communication path over the CDMA network. With this simple communications add-on, almost every panel can take advantage of revenue-building remote system management and control features. Arming & disarming come standard along with the ability to view up to six cameras. Program your own account number to easily work around locked panels. Add Z-Wave control of lights, locks, and thermostats with the CellComSLCZ. For use with: Burglary Alarm Control Panels. CELLCOMSLCF UNIVERSAL FIRE ALARM COMMUNICATOR CELLCOMSLCF The CellComSLCF Fire Alarm Communicator provides a fully supervised alarm communication path over the CDMA network and meets the NFPA 72 standard for commercial fire applications. It provides alarm dealers with a fire solution to update existing customer panels or takeovers. Dealers don't have to worry about lock-out codes; they can just add the DMP CellComSLCF unit onto the existing dialer installations and benefit from DMP Alarm features. 12/24 VDC. For use with: Fire Alarm Control Panels. WHEN CHOOSING A CONTROL PANEL PARTNER 1. Designed, engineered & manufactured in Springfield, MO by and for alarm people. 2. Dealer Direct relationship makes you a member of an elite dealer program. 3. 100% testing of our products before shipping. 4. Backward, forward & horizontal product compatibility. 5. Commercial-grade 2-way wireless offers extreme range & unique capabilities. 6. A complete family of attractive branded user interfaces. 7. We say what we do. We do what we say. You can count on it. 8. Experienced professional sales, technical training & support. 9. We insist on the integrity of our products and our people. 10. Customers tell us we are innovative, reliable & provide them with excellent support. We take the success of your business personally. WE MAKE YOUR COMPANY MORE VALUABLE. 141 FAX: 800.743.5724 380-400 SIM CARD ORDER: 380-400 Replacement SecureCom Wireless SIM card for DMP Cellular Communicators. For use with: XTL, 263G,263H and CellComRT Cellular Communicators. 381 COAX EXTENSION CABLE ORDER: 381-12 (12 FT) 381-25 (25 FT) Coax antenna extension cable with SMA connectors. For use with: All DMP Cellular Communicators. 381-2 COAX EXTENSION CABLE Coax antenna extension cable with SMA connectors for connection from any DMP cell module to the antenna via the enclosure knock-out. ORDER: 381-2 (18 IN) For use with: All DMP Cellular Communicators. CUSTOMER SERVICE: 866.266.2826 142 P OMOTION/LITE ATURE CELLULAR COMMUNICATION PROMOTIONAL ITEMS 383 DUAL BAND RUBBERDUCK ANTENNA ORDER: 383 Dual Band 850/1900 portable antenna mounts on the XR500 control panel enclosure. For use with: All DMP Cellular Communicators. 386 OUTDOOR ANTENNA MOUNTING BRACKET ORDER: 386 Outdoor Chrome 90 degree antenna mounting bracket with a 5/8 inch opening. 387-1 3DB FIBERGLASS ANTENNA W/BRACKET The Antennex/Laird Dual-Band Cellular Fiberglass antenna is a convenient and highly durable solution. Supports 800/850MHz Cellular frequency band and 1900MHz PCS frequency band. This antenna has a N/Female connector at the base and requires Model 387-25, 387-50, or equivalent cable. 387-2 2DB ATTACK ENCLOSURE ANTENNA This Nearson Antenna comes with a standard SMA Plug connector for use in conjunction with a Model 350A Attack Enclosure, or any 350 enclosure. QuadBand capable, it covers frequency ranges between 824-960 MHz and 17102170 GHz (AMPS/GSM/DCS/PCS Bands.) Gain is 2 dBi. For use with: 383 Antenna. DMP 40 YEAR ANNIVERSARY COFFEE MUG ORDER: AD-0026 DMP SCREWDRIVER ORDER: AD-0002 100% combed cotton short sleeve golf shirt. DMP GOLF SHIRTS ORDER: AD-0003-BL (L) AD-0003-BXL (XL) DMP GOLF BALLS ORDER: AD-0009 DMP STAINLESS STEEL EXECUTIVE MUG ORDER: AD-0012 DMP CAMO LOGO CAP ORDER: AD-0019-TAN Black ceramic coffee mug with 40 year anniversary logo. DMP 1975-2015. Handy pocket screwdriver with straight blade. Black with gold DMP logo. ORDER: 387-1 For use with: GSM Cellular Communicators. ORDER: 387-2 One sleeve of three Titleist® NXT Distance golf balls. A black and gold DMP logo appears on each white golf ball. For use with: GSM Cellular Communicators. Stainless steel covered mug with DMP logo. 387-3 3DB MEG ANTENNA This antenna when coupled with a stainless steel exterior mounting bracket,with integrated ground plane, makes a perfect antenna for improving cellular reception for just about any cellular installation. This antenna has aN/Female connector at the base and requires Model 387-25, 387-50, or equivalent cable 387 SMA TO N CABLE, LMR195 SMA Extension Cable. ORDER: 387-3 For use with: GSM Cellular Communicators. Camo Olive Tan Brushed Cotton Twill Cap with DMP logo. ORDER: 387-4 (4 FT) 387-8 (8 FT) 387-25 (25 FT) 387-50 (50 FT) For use with: 387 Series Cellular Antennas. 143 FAX: 800.743.5724 CUSTOMER SERVICE: 866.266.2826 144 PROMOTION/LITE ATURE SALES LITERATURE SALES LITERATURE CONT. RESIDENTIAL DIECUT THINLINE/AQUALITE BROCHURE ORDER: LT-0876 COMMERCIAL DIECUT THINLINE/AQUALITE BROCHURE ORDER: LT-0873 ORDER: LT-0927/25 RETAIL “MAKING CONNECTIONS” END-USER BROCHURE ORDER: LT-0993/25 Make a professional first impression with these dynamic new brochures featuring your retail applications expertise. Package of 25. Actual-size brochure design is an attractive and practical leave behind that shows residential prospects just how good security can look. Actual-size brochure design is an attractive and practical leave behind that shows commercial prospects just how good security can look. THINLINE ICON KEYPAD BROCHURE RETAIL SECURITY BROCHURE ORDER: LT-0959 The brochure is targeted to both residential and commercial installations where style and ease-of-use are key components of the sale. Also features a call-out page of features and benefits. Present your retail prospects with the companion piece to the Retail Brochure. This brochure presents an overview of the importance and benefits of the various communication options available between the XT Series panel and the monitoring service, as well as solutions to protect their inventory and employees. Imprint your logo and address on the back of the brochure. Package of 10. GOVERNMENT SOLUTIONS BROCHURE Make a professional first impression with these dynamic new brochures featuring your government applications expertise. Package of 25. POSTCARD A fast and effective way to spread the word about the latest keypad innovations from DMP. Postcards measure 4.75" x 7" AQUALITE™ INVOICE STUFFERS ORDER: LT-0877 ORDER: LT-0931/25 Aqualite keypad invoice stuffers are sized to fit in invoicing envelopes along with tri-fold brochures for convenient, cost-effective end-user marketing. Perfect for upselling keypads to existing customers or for appealing to new prospects. Package of 25. THINLINE INVOICE STUFFERS ORDER: LT-0933/25 Thinline keypad invoice stuffers are sized to fit in invoicing envelopes along with tri-fold brochures for convenient, cost-effective end-user marketing. Perfect for upselling keypads to existing customers or for appealing to new prospects. Package of 25. DMP FAMILY POSTER ORDER: LT-0928/25 SYSTEM LINK ORDER: LT-0600/25 ENTRE ORDER: LT-1022/25 DMP CORPORATE BROCHURE ORDER: LT-1040/25 This full-color brochure highlights the features of System Link, DMP’s end-user alarm panel management software. System Link allows users to easily control their DMP system from their personal computer. Endusers are able to set-up new system users, configure new panel accounts, monitor system status, and more. Package of 25. This full-color brochure highlights the features of Entré. With DMP Entré, users can manage both intrusion and access control in one easy-to-use software application. System managers can now have fast, simple point-andclick control over every aspect of their security system. Package of 25. Get to know DMP better with our corporate brochure. Learn about our features and benefits as well as our history of innovation. Package of 25. ORDER: LT-0889 “Welcome to the Family” poster featuring the Aqualite™ Keypad, the latest in the Thinline™ Series of ultra-low profile keypads. Poster measures 23” x 35” and is perfect for your showroom, office, or lobby. ORDER: LT-1054/25 ACCESS CONTROL BROCHURE Make a professional first impression with this dynamic new brochure featuring your Access Control expertise. Package of 25. NETWORK MONITORING BROCHURE Spells out the value of network monitoring and DMP’s leadership since the beginning of the digital revolution. Package of 25. 145 FAX: 800.743.5724 ORDER: LT-0879/25 CUSTOMER SERVICE: 866.266.2826 146 PROMOTION/LITE ATURE SALES LITERATURE CONT. SALES LITERATURE CONT. SCHOOL SECURITY BROCHURE ORDER: LT-1064/25 CAMPUS SECURITY BROCHURE ORDER: LT-1065/25 Make a professional first impression with this dynamic new brochure featuring your expertise in security solutions for schools. Package of 25. Make a professional first impression with this dynamic new brochure featuring your campus applications expertise. Package of 25. DESIGNER SERIES KEYPAD SWATCHES Your customers can thumb through the amazing variety of options available in the DMP Designer Series Keypad Covers. Whether they want their keypad to blend in or stand out as a bold statement of their individuality, the selection process will be easier with this swatch book of available designs. The ring-bound sample set shows each option as it appears on the keypad. They can browse through the wood grains,diamond plate, bandana, patriotic, camouflage, and other styles to find the keypad cover that exactly matches their design desires. 12 REASONS POSTER ORDER: LT-1084 MYACCESS™ RESIDENTIAL BROCHURE ORDER: LT-1093/25 MYACCESS™ COMMERCIAL BROCHURE ORDER: LT-1094/25 MYACCESS INVOICE STUFFERS ORDER: LT-1124/25 FAX: 800.743.5724 COMMUNICATION OPTIONS BROCHURE ORDER: LT-1184-1/25 RESIDENTIAL FIRE INVOICE STUFFERS ORDER: LT-1190/25 COMMERCIAL VIDEO INVOICE STUFFERS ORDER: LT-1258/25 XTL RESIDENTIAL BROCHURE ORDER: LT-1262/25 XTL COMMERCIAL BROCHURE ORDER: LT-1263/25 Z-WAVE & VIDEO SALES POSTER ORDER: LT-1267/25 Fires are frightening. Insert this tear sheet in your next invoice or mailer and make sure your customers are aware of home fire security systems. Available both as a stock item or customized with your logo and contact information, the tearsheet encourages homeowners to contact you to learn more about how to protect themselves and their home with a professionally installed fire security system. Package of 25. "12 Reasons" poster featuring the 12 reasons to use DMP advertisements. Poster measures 36" x 24" and is perfect for your showroom, office, or lobby. 147 ORDER: LT-1183-1/25 This end-user tri-fold 4" x 9.25" brochure will help residential customers understand the different communication options acailable for their security system. Those considering switching from dial-up to VOIP or network connection can learn about the potential benefits and drawbacks of each communication option. This brochure encourages end-users to rely on a reputable, professional system installer for their security needs. Package of 25. ORDER: LT-1086/25 Perfect for upselling to existing customers or appealing to new prospects. This quick and easy sales tool puts the latest alarm communication innovation "MyAccess" at their finger tips. These invoice stuffers are sized to fit in invoicing envelopes along with tri-fold brochures for convenient, costeffective end-user marketing. Package of 25 DOOR KNOCKER BROCHURE ORDER: LT-1079 DESIGNER SERIES KEYPAD INVOICE STUFFERS This end-user Commercial brochure points out the benefits of the MyAccess™ messaging features, it reviews the status messages customers can opt to receive as well as the list of commands they can send to control their system. This brochure will impress your clients with the simplicity and convenience of the MyAccess™ Messaging Features. Package of 25 ORDER: LT-1140/25 Perfect for upselling to existing or new customers with fire applications. This quick and easy sales tool promotes the latest money savings fire alarm communication innovation. These invoice stuffers are sized to fit in invoicing envelopes along with tri-fold brochures for convenient, cost-effective end-user marketing. Package of 25 This end-user tri-fold brochure 4" x 9.25" will make a professional impression on your residential customers with helpful advice. Users learn of the threat of potential door-to-door security sales people, and potential clients are informed of the best way to purchase their first home security system. Brochure includes a check-list of ideas to consider before signing a new security system contract and also when to beware of certain sales tactics. Package of 25. This quick and easy sales tool puts the latest keypads in their very best light. Available for Aqualite and Thinline, keypad invoice stuffers are sized to fit in invoicing envelopes along with tri-fold brochures for convenient, costeffective end-user marketing. Perfect for upselling to existing customers or for appealing to new prospects. Invoice Stuffers come in a package of 25 sold as a unit. This end-user Residential brochure points out the benefits of the MyAccess™ messaging features, it reviews the status messages customers can opt to receive as well as the list of commands they can send to control their system. This brochure will impress your clients with the simplicity and convenience of the MyAccess™ Messaging Features. Package of 25 FIRE COMMUNICATIONS INVOICE STUFFERS Perfect for upselling to existing customers or appealing to new prospects. Encourages customers to contact you regarding adding video cameras to theirsecurity system. These invoice stuffers are sized to fit in invoicing envelopes along with tri-fold brochures for convenient, cost-effective end-user marketing. Sold in pkgs of 25 sheets as 1 unit This new XTL brochure is the economical way to make a professional impression during sales calls, in direct mail campaigns, and at exhibitions. The XTL system is ideal for residential applications. End-users will learn about the XTL Wireless System and how it provides simple and affordable mobile control. Package of 25. This new XTL brochure is the economical way to make a professional impression during sales calls, in direct mail campaigns, and at exhibitions. The XTL system is ideal for commercial applications. End-users will learn about the XTL Wireless System and how it provides simple and affordable mobile control. Package of 25. Highlight your newest technology with the DMP Z-Wave and Video Sales Poster. Measuring 36" wide by 24" tall, this poster is the perfect addition to your office showroom or tradeshow material. . CUSTOMER SERVICE: 866.266.2826 148 PROMOTION/LITE ATURE SALES LITERATURE CONT. DMP RESIDENTIAL TRI-FOLD BROCHURE Check out our latest residential tri-fold brochure! This brochure provides an economical way to make a professional impression during sales calls, in direct mail campaigns, or at trade shows. Package of 25. DMP COMMERCIAL TRI-FOLD BROCHURE Check out our latest commercial tri-fold brochure! This brochure provides an economical way to make a professinal impression during sales calls, in direct mail campaigns, and at trade shows. Package of 25. SALES LITERATURE CONT. ORDER: LT-1284/25 ACTIVE VIOLENCE BROCHURE ORDER: LT-1375/25 VIRTUAL KEYPAD APP DIECUT COMMERCIAL BROCHURE ORDER: LT-1381/25 DMP RESIDENTIAL BROCHURE ORDER: LT-4100/25 DMP COMMERCIAL BROCHURE ORDER: LT-4150/25 Make a professional first impression with this dynamic new brochure discussing Active Violence in commercial facilities. Main features include door lockdown and panic key fobs/transmitters. Package of 25. ORDER: LT-1285/25 Showcase the features of the Virtual Keypad App 4.0 to your customers in this sleek, new brochure. Displays actual App icons and explains available commands - from arming/disarming, to controlling Z-Wave devices and cameras. Sold in packs of 25 FINANCIAL SECURITY BROCHURE Make a professional first impression with this dynamic new brochure featuring your financial applications expertise on banking security. Package of 25 VIRTUAL KEYPAD APP DIECUT RESIDENTIAL BROCHURE Showcase the features of the Virtual Keypad App 4.0 to your customers in this sleek, new brochure. Displays actual App icons and explains available commands - from arming/disarming, to controlling Z-Wave devices and cameras. Sold in packs of 25. VIRTUAL KEYPAD APP INVOICE STUFFER Perfect for upselling to existing customers or appealing to new prospects. Encourages customers to contact you regarding the new Virtual Keypad App 4.0 to control their system. These invoice stuffers are sized to fit in invoicing envelopes along with tri-fold brochures for convenient, cost-effective end-user marketing. Pkg of 25 sheets - sold as 1 unit. ORDER: LT-1296/25 Present your residential prospects with an overview of the security systems you offer and the many added features that help to create home automation for your customers. Added space on the back of the brochure to imprint your company's logo and address if desired. Package of 25. ORDER: LT-1362/25 Present your commercial prospects with an overview of the security systems you offer along with the many features that help to create a simple business automation system. Additional space is provided on the back of the brochure to imprint you logo and address if desired. Package of 25. ORDER: LT-1365/25 TRAINING 2015 DMP FALL CATALOG ON CD ORDER: CD-0007 TECHNICAL NOTEBOOK ORDER: TECH NOTEBOOK View our complete line of products via our electronic catalog. To quickly view a specific page, simply click on that page as listed in the Table of Contents. Model Numbers for ordering are indicated on the right side of each product listing. 7800 TOUCHSCREEN KEYPAD INVOICE STUFFERS Perfect for upselling to existing customers or appealing to new prospects. Encourages customers to contact you regarding the new 7800 Series Graphic Touchscreen Keypads. These invoice stuffers are sized to fit in invoicing envelopes along with tri-fold brochures for convenient, costeffective end-user marketing. Package of 25 sheets - sold as 1 unit. GRAPHIC TOUCHSCREEN KEYPAD DIECUT BROCHURE Actual-size brochure design is an attractive and practical leave-behind that shows prospects just how good security can look. Package of 25. 149 FAX: 800.743.5724 ORDER: LT-1305/25 ORDER: LT-1311/25 The DMP Technical Notebook is a must for every installer! This 3 volume set contains spec sheets, installation guides, application notes, and more on each DMP product. This manual is your comprehensive guide to installing and servicing DMP products. CUSTOMER SERVICE: 866.266.2826 150 FEATURE COMPA ISON XR XR XR Yes Yes Yes Yes Yes Number of Possible Hardwired Zones 0 0 38 38 142 574 142 574 Add/Delete/Change User Codes Yes Yes Yes Yes Yes Yes Yes Yes Number of Possible DMP Wireless Zones 28 28 28 48 100 500 100 500 Add/Delete/Change Schedules No No No No Yes Yes Yes Yes Number of Areas 6 6 6 6 8 32 8 32 LC XT 50 30 LC 0 55C XR0F 55 Yes 0 15C XR0F 15 Yes 0 50C XR0F 50 0 10C XR0F 10 XR 50 Yes XT Swinger Bypass/Reset Reports XT 574 0 55C XR0F 55 142 0 15C XR0F 15 574 0 50C XR0F 50 142 0 10C XR0F 10 58 XT 38 XT 28 LN XT IFI -W 30 LN XT IFI -W LN XT XR XR XR LN XR XT 28 XT Total Number of Zones Panel Specifications System Reports Continued Event Buffer 100 100 100 200 12,000 12,000 12,000 12,000 Number of User Codes 30 30 30 99 10,000 10,000 10,000 10,000 Number of Door Access Points No No 8 8 8 16 8 16 Number of Supervised Keypads 4 4 8 8 8 16 8 16 Auxiliary Power N/A N/A 500mA 500mA 1.5 Amp 1.5 Amp 1.5 1.5 Amp Switched 4-wire Smoke Detector Power N/A N/A 100mA 100mA Yes Yes Yes Yes Bell Power N/A N/A Form C Relay Outputs 0 0 0 Annunciator Outputs N/A N/A 24 VDC NAC N/A Number of Possible Z-Wave® Devices 232 1.5 Amps 1.5 Amps 1.5 Amps 1.5 Amps 1.5 Amps 1.5 Amps 0 2 to 106 2 to 506 2 to 106 2 to 506 4 4 4 to 178 4 to 578 4 to 178 4 to 578 N/A N/A N/A Optional Optional Optional Optional 232 232 232 N/A N/A 232 232 Communication Options Digital Dialer with Serial 3 Communication No No Full Communication Over Data Networks No Yes Yes Yes XT30 “N” XT50 “N” Yes Yes XR100N XR500N XR500E XR550 XR150 "N" "N" or "E" Yes Yes w/263C Yes w/263C or H or H Yes w/263C Yes w/263C Yes w/464 or H or H Zone Name Sent to Receiver Yes Yes Yes Yes Yes Yes Yes Yes Test Reports Yes Yes Yes Yes Yes Yes Yes Yes Ambush Reports Yes Yes Yes Yes Yes Yes Yes Yes System Link™ for Windows Yes Yes Yes Yes Yes Yes Yes Yes Remote Link™ for Windows Yes Yes Yes Yes Yes Yes Yes Yes Area Arming Yes Yes Yes Yes Yes Yes Yes Yes All/Perimeter Arming Yes Yes Yes Yes Yes Yes Yes Yes Home/Sleep/Away Arming Yes Yes Yes Yes Yes Yes Yes Yes Auto Arming/Disarming Yes Yes Yes Yes Yes Yes Remote Upload/Download Operational Features Yes Yes Multi-lingual Programming/User Menu No No No No Yes Yes Yes Yes Phone Access™ No No Yes Yes No No No No Zone Activity, Elderly Check-in Option Yes Yes Yes Yes No No No No Easy Exit™ Momentary Disarming Yes Yes Yes Yes Yes Yes Yes Yes Easy Entry™ Access Control Yes Yes Yes Yes Yes Yes Yes Yes Armed Activity Check-in Option Yes Yes Yes Yes No No No No Keypad Programmable Yes Yes Yes Yes Yes Yes Yes Yes System Diagnostics From Keypad Yes Yes Yes Yes Yes Yes Yes Yes Keyswitch Arming Yes Yes Yes Yes Yes Yes Yes Yes Cellular Yes No Encrypted Communications No No No No No XR500E No XR550 "E" Contact ID Reporting Format No No Yes Yes Yes Yes Yes Yes Smartphone App Yes Yes Yes Yes Yes Yes Yes Yes Local Printer Support No No No No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes SMS Text Messages Yes No Yes Yes Yes Yes Yes Yes Ambush Code Dual Reporting to Two Receivers Yes Yes Yes Yes Yes Yes Yes Yes Opening/Closing Schedules No No 1 1 4 per Area 4 per Area 4 per Area 4 per Area Dual Phone Line Capability No No No Yes Yes w/893A Yes w/893A Yes w/893A Yes w/893A Programmable Relay Schedules No No No Yes - 4 Yes - 100 Yes - 100 Yes - 100 Yes - 100 Holiday Schedules No No No No Yes Yes Yes Yes 8 Communication Paths No No No No Yes Yes Yes Yes Enhanced Schedules No No No No No No Yes Yes Adaptive Technology No No No No Yes Yes Yes Yes Anti-Passback by Door and User No No No No Yes Yes Yes Yes System Reports False Alarm Reduction Features Openings and Closings Yes Yes Yes Yes Yes Yes Yes Yes Cross Zoning Yes Yes Yes Yes Yes Yes Yes Yes Recall Test Reports Yes Yes Yes Yes Yes Yes Yes Yes Transmission Delay Yes Yes Yes Yes Yes Yes Yes Yes AC/Battery Fail and Restoral Yes Yes Yes Yes Yes Yes Yes Yes Entry/Exit Error Warning Yes Yes Yes Yes Yes Yes Yes Yes Bypass Reports by Zone Yes Yes Yes Yes Yes Yes Yes Yes Fire Verification Yes Yes Yes Yes Yes Yes Yes Yes Door Access Reports by Keypad No No No No Yes Yes Yes Yes Full English Reporting to Receiver 151 Yes FAX: 800.743.5724 Yes Yes Yes Yes Yes Yes Yes Fire Retard by Zone No No No No Yes Yes Yes Yes Swinger Bypass Yes Yes Yes Yes Yes Yes Yes Yes Abort Reports Yes Yes Yes Yes Yes Yes Yes Yes CUSTOMER SERVICE: 866.266.2826 152 P ODUCT COMPATIBILITY l l l 2W-LX l l l l 2WT-BLX l l l l 7060/7060A l l l l l l 7063/7063A l l l l l l 7070/7070A l l l l l l 734 7073/7073A l l l l l l 7160/7163 l l l l l 7170/7173 l l l l 7360/7363 l l 7760 l l l 7862/7863 l l l ACCESS CONTROL s rie Se 0 s 55 ie r XR Se 0 s 15 ie XR Ser 0 s 50 rie XR 0 Se s 10 ie XR Ser 50 e s XT eri S 30 IFI XT -W LN XT TLN X C l L XT s rie Se 0 55 ries XR Se 0 s 15 ie XR Ser 0 es i 50 r XR 0 Se s 10 ie XR Ser 50 e s XT eri S 30 IFI XT -W LN XT TLN X C L XT 630F L XT s rie Se 0 55 ries XR Se 0 es 15 i XR Ser 0 s 50 rie XR 0 Se s 10 ie XR Ser 50 e s XT eri S 30 IFI XT -W LN N L XT XT C s rie Se 0 55 ries XR Se 0 es 15 i XR Ser 0 s 50 rie XR 0 Se s 10 ie XR Ser 50 e s XT eri S 30 IFI XT -W LN N L XT XT C L XT SMOKE DETECTORS KEYPADS 1100 SERIES WIRELESS 1100D SYSTEM ACCESSORIES CONTINUED l l 322 l l 1100DI l l 323 l l 1100DH l l 324 l l l l l l 1100X l l l l 324P l l 734N l l l l 1100XH l l l l 325 l l l 734N-WIFI l l l l 1100R l l l l l l l l l 327 l l l l 1306P l l l l l l l l l 1101/1102 l l l l l l l l l 330 1326 l l l l l l l l l 1103 l l l l l l l l l l l l 1346 l l l l l l l l l 1105 l l l l l l l l l l l l 1351 l l l l l l l l l 1107 l l l l l l l l l 371-500 l 1386 l l l l l l l l l l l l l l l l l 335 l l l l 370 and 370RJ l l l l l l l l l l l l l l 1114 l l l l l l l l l 372-500 9060 l l l l l l l l l 1116 l l l l l l l l l 374 9063 l l l l l l l l l 1117 l l l l l l l l l 377 9862 l l l l l l l 1118 l l l l 399 l l l l l l l l l 572 l l 7872/7873 EXPANSION MODULES 1119 l l l l 708 l l l l l l 1121 l l l l l l l l l 3012 l l l l 710 l l l l l l 1125 l l l l l l l l l RP-44 l l l l 711 l l l l l l 1126C/1126R/1126W l l l l l l l l l PSD100 l l l l 712-8 l l l l l l 1127C/1127W l l l l l l l l l 714 l l l l l l 1129 l l l l l l l l l 340 l l 714-8/16 l l l l l l 1131 l l l l l l l l l 341 l l l l 715 l l l l l l 1135/1135DB l l l l l l l l l 349 l l 715-8/16 l l l l ENCLOSURES l l l l 1137 l l l l l l l l l 349A 716 l l l l 1139 l l l l l l l l l 350 l l 717 l l l l 1142/1142BC l l l l l l l l l 350A l l 736P l l l l l l 1145-1-B/1145-2-B/1145-4-B l l l l l l l l l 352S l 738A l l l l l l 1148 l l l l l l l l l 352X l 738I l l l l l l 1161/1162 l l l l l l l l l l l l l 1164 l l l l l l l l l SCS-1R l l l l l 1165/1165H/1165HS l l l l SCS-105 l 461 l l 462N l l 738Z l l l 739 INTERFACE CARDS 1183-135F/1183-135R l l l l l l l l l 1184 l l l l l l l l l Z-WAVE® CENTRAL STATION RECEIVERS l l l l l l l l l l l l SCS-VR l l COMPUTER SOFTWARE AND HARDWARE Remote Link l l l l l l l 462P l Z-45602/Z-45603 l l l l l l l l l System Link l l l l l l l 472 l Z-45740 l l l l l l l l l Account Groups l l l l l l Z-45741 l l l l l l l l l Alarm Monitoring l l l l l l l 481 Z-45742 l l l l l l l l l Command Center l l l l l l l 860 l l l l Z-5010T l l l l l l l l l Advanced Reports l l l l l l l 861 l l l l Z-99100-004 l l l l l l l l l Link Server l l l l l l l 865 l l l l Z-99100-005 l l l l l l l l l Admin Reader l l l l l l l 866 l l l l Z-99100-006 l l l l l l l l l SCS-CTM l l l l l l l 867 l l Z-GD00Z-4 l l l l l l l l l SQL Module l l l l l l l 869 l l Z-LB60Z-1 l l l l l l l l l Entré l l l l 893A l l AUXILIARY MODULES NETWORK COMMUNICATIONS 462N POWER SUPPLIES l CELLULAR COMMUNICATIONS 505-12 l l l l l l 505-12A/505-12L l l l l l l 263C l l l l l l l l 263H l l l l l l 300 l l l l 303 l l l l 505-12LX PULL STATIONS 850S/850D l l 850S/711 Keypad Bus Keypad Bus l l 850D/711 Keypad Bus Keypad Bus l l SYSTEM ACCESSORIES 305 306 l l l l l l l l 307-S l l l l 320 l l 321 l l 307 For Battery Calculation Charts access: www.dmp.com This chart denotes functional compatibility only. Functional compatibility does not ensure an approved installation. Refer to the Product Approval chart on the next page and the specific panel Installation Guide for approved compliance information. 153 FAX: 800.743.5724 CUSTOMER SERVICE: 866.266.2826 154 TERMS AND CONDITIONS GENERAL: These terms and conditions represent the entire agreement between you, the “Buyer”, and Digital Monitoring Products Inc. ("DMP"). All transactions between buyer and DMP are expressly subject to and conditioned upon the terms and conditions set forth herein. Any different or conflicting terms or conditions set forth by the Buyer, whether in Buyer’s purchase order or another communication, are expressly objected to and will not be binding on DMP unless agreed to in writing by an authorized officer of DMP. In the absence of such an agreement, commencement of performance and/or delivery shall be for Buyer's convenience only and shall not be deemed or construed to be acceptance of Buyer's terms and conditions. If a contract is not earlier formed by mutual agreement in writing, acceptance of any products by Buyer shall be deemed acceptance of the terms and conditions stated herein. This contract may not be assigned, modified or canceled by Buyer without DMP's prior written consent, and any attempt to assign, modify or cancel it without such consent shall be absolutely void. No delay or omission to exercise any right, power or remedy accruing to DMP upon breach or default by Buyer under this contract shall impair any such right, power or remedy of DMP, or shall be construed as a waiver of any such breach or default. All waivers must be in writing. In the event any of the provisions hereof shall, for any reason, be held void or unenforceable, the remaining provisions shall remain in full force and effect and shall control. Any provisions of this contract prohibited by law of any state shall, as to said state, be ineffective to the extent of such prohibition without invalidating the remaining provisions of this contract. Orders will become effective only when accepted by DMP. All prices, terms, discounts, and specifications are subject to change without notice. Orders will be filled at the prices that are in effect at the time of DMP’s receipt of your order. Special orders for items not normally stocked are non-cancelable and non-refundable. Shipments, deliveries, and performance of work shall at all times be subject to the approval of DMP's credit department. DMP may at any time decline to make any shipment or delivery or perform any work except upon receipt of payment or acceptable security, or upon other terms and conditions satisfactory to DMP's credit department. TERMS: INITIAL ORDERS WILL BE SHIPPED C.O.D. (CASH, MONEY ORDER, CERTIFIED CHECK OR APPROVED CREDIT CARD ONLY) UNLESS A LINE OF CREDIT HAS BEEN PREVIOUSLY ESTABLISHED. TERMS TO CUSTOMERS WITH APPROVED CREDIT ARE 1%/10 DAYS, NET 30 DAYS. CREDIT CARD PAYMENTS WILL ONLY BE ACCEPTED AT THE TIME OF ORDER. IF A CREDIT CARD IS USED TO PAY A BALANCE DUE FOR A CUSTOMER ON APPROVED TERMS, THERE WILL BE A 3% SERVICE CHARGE ADDED TO THE AMOUNT PROCESSED. PAST DUE ACCOUNTS WILL HAVE THEIR CREDIT LINE IMMEDIATELY SUSPENDED. ORDERS SHIPPED TO PAST DUE ACCOUNTS AND ORDERS EXCEEDING CREDIT LIMIT WILL ONLY BE SHIPPED C.O.D. OR APPROVED CREDIT CARD PAYMENT IN ADVANCE. ALL AMOUNTS PAST DUE PLUS SERVICE CHARGES AND COLLECTION EXPENSES (AS DEFINED BELOW) MAY BE ADDED TO ANY C.O.D. OR CREDIT CARD PAYMENT. AMOUNT OR OTHER CHARGES, AND ACCEPTANCE AND SHIPMENT OF ANY ORDER MAY BE CONDITIONED UPON PAYMENT OF ANY SUCH AMOUNTS. DMP MAY, IN ITS SOLE DISCRETION, AT ANY TIME AND FROM TIME TO TIME CHANGE THE TERMS OF BUYER'S CREDIT, REQUIRE PAYMENT IN CASH BEFORE SHIPMENT OF ANY OR ALL OF PRODUCTS ON ORDER, AND/OR REQUIRE ANTICIPATED PAYMENT OF ANY OR ALL AMOUNTS DUE OR TO BECOME DUE. IF DMP BELIEVES THAT BUYER'S ABILITY TO MAKE PAYMENTS IS OR MAY BE IMPAIRED, DMP MAY CANCEL ANY OR ALL PENDING ORDERS. BUYER SHALL RETAIN LIABILITY FOR PAYMENT FOR ANY PRODUCTS ALREADY SHIPPED. CHECKS ARE ACCEPTED SUBJECT TO COLLECTION AND THE DATE OF COLLECTION SHALL BE DEEMED THE DATE OF PAYMENT. TAXES/FREIGHT/ CLAIMS: Unless otherwise agreed to in writing, the amount of all transportation charges and of all taxes or other charges now or hereafter imposed upon the sale, purchase, resale, delivery, manufacture, production or possession of the products specified herein, which may be paid by DMP or for which DMP may be liable, shall be paid to DMP by Buyer in addition to the purchase price of the products. Sales tax will be charged where applicable unless a current and valid certification of exemption of Buyer is on file at DMP. All shipments are F.O.B. DMP Plant, Springfield, Missouri. All risk of loss shall pass to Buyer upon shipment of the products to Buyer. All claims for damage, loss or otherwise must be made within 7 days of the date of shipment. All claims for damage incurred in shipment shall be the responsibility of the carrier, and should be placed with the carrier. RESALE OF PRODUCTS/ TRANSSHIPMENTS: Buyer may not resell DMP's products or other equipment sold by DMP to parties other than an end user without written permission from DMP first being obtained. Unauthorized resale may result in termination of sales to Buyer. Buyer may not transship DMP's products or other equipment sold by DMP to other branch locations without written permission from DMP first being obtained or without a DMP Training Certification having been previously issued to that specific branch location. Buyer may not redirect DMP's products or other equipment sold by DMP to another Dealer without written permission from DMP first being obtained. Unauthorized transshipments or redirects may result in termination of sales to Buyer. INSTALLATION/ TECHNICAL DATA: Buyer shall be solely responsible for the installation and operation of the products covered hereby including without limitation, obtaining and maintaining in full force and effect, all permits, licenses or certificates required for the installation or use of such products. Installations must be performed by a certified and trained DMP Dealer. Unauthorized installations may result in termination of sales to Buyer and will void any warranty or repair obligations of DMP as set forth herein or otherwise. Buyer shall not use, duplicate or disclose any technical data delivered or disclosed by DMP to Buyer for any purpose other than for installation, operation or service of products purchased by Buyer, without DMP's prior written consent first being obtained. Buyer acknowledges and agrees it shall not in any form export, re-export, resell, ship or divert or cause to be exported, reexported, resold, shipped or diverted, directly or indirectly, any technical data or product without DMP's express prior written consent first obtained. Buyer will not use, and will advise the end user not to use any of DMP's products or other equipment sold by DMP for any criminal, illegal, or otherwise unlawful activity including video voyeurism or invasion of privacy. SOFTWARE: Computer software, if any, is provided by DMP to Buyer pursuant solely to a single user license, the royalty, terms and conditions of which are set forth in the software license agreement or end user license agreement applicable to that specific Software and in all instances remains the sole and exclusive property of DMP. LIMITED WARRANTY: DMP warrants that the products manufactured by DMP and described herein, shall be free from defects of manufacture, labeling, and packaging for a period of three (3) years from the invoice date to the original Buyer, provided that representative samples of the defective products are returned to DMP for inspection. Upon a determination by DMP that a product is not as warranted, DMP shall, at its exclusive option, and as its sole obligation, replace or repair said defective product or part thereof at its own expense except that Buyer shall pay all shipping, insurance and similar charges incurred in connection with the replacement of the defective product or parts thereof. Products sold but not manufactured by DMP (OEM products) are subject solely to the terms and conditions of that manufacturer’s warranty, if any, applicable to such products. The sole purpose of any sale or contract for sale of any of the products listed in the DMP catalog or price list is the furnishing of that product. It is expressly understood by Buyer that in furnishing any of such products, DMP does not warrant or insure the Buyer against any losses the Buyer or any end user of the product may incur, even if resulting from the malfunction of said product. DMP does not warrant or represent that the products sold may not be compromised or circumvented, will operate as designed, will prevent or reduce personal injury, property damage or economic loss, or will provide adequate warning or notice as designed or may be intended by Buyer or any end user. Buyer understands and will cause its customers to understand that a properly installed and maintained alarm system may only reduce the risk of a burglary, robbery, or fire without warning, but it is not insurance or a guarantee that such will not occur or will not cause or lead to personal injury or property loss. All warranties are void if a product is damaged, becomes defective or malfunctions due to accident, abuse, vandalism, neglect, negligence, any modification, improper installation, service, or testing, misapplication, misuse, lightning, electricity, water, fire, environmental or other hazard, or act of God, or if for any other reason DMP determines that said product is not operating properly as a result of causes other than defective manufacture, labeling, or packaging. No employee or agent of DMP’s is authorized to make any warranty other than that specifically set forth herein. The provisions in any specification or chart issued by DMP or attached hereto are descriptive only and are not warranties. THE AFORESAID LIMITED WARRANTY IS EXPRESSLY MADE IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, IT BEING UNDERSTOOD THAT ALL SUCH OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. IN NO EVENT SHALL DMP OR ITS REPRESENTATIVES BE LIABLE TO BUYER FOR ANY DIRECT, INDIRECT, COLLATERAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH BUYER'S OR END USER’S USE OF ANY OF THE PRODUCTS LISTED HEREIN, OR FOR ANY OTHER CAUSE WHATSOEVER RELATING TO THE SAID PRODUCTS, INCLUDING DAMAGES RELATIVE TO, ARISING FROM, OR CAUSED DIRECTLY OR INDIRECTLY BY SAID PRODUCTS OR THE USE THEREOF OR ANY DEFICIENCY, DEFECT, OR INADEQUACY OF THE SAID PRODUCTS. IT IS EXPRESSLY AGREED THAT BUYER'S EXCLUSIVE REMEDY FOR ANY CAUSE OF ACTION RELATING TO THE PURCHASE AND/OR USE OF ANY OF THE PRODUCTS LISTED HEREIN FROM DMP SHALL BE FOR ACTUAL DAMAGES ONLY, AND DMP'S LIABILITY FOR ANY AND ALL LOSSES OR DAMAGES RESULTING FROM ANY CAUSE WHATSOEVER INCLUDING ACTIVE OR PASSIVE NEGLIGENCE OR OTHER FAULT SHALL IN NO EVENT EXCEED THE PURCHASE PRICE OF THE PRODUCT IN RESPECT TO WHICH THE CLAIM IS MADE, OR AT THE ELECTION OF DMP THE RESTORATION OR REPLACEMENT OR REPAIR OF SUCH PRODUCT. BUYER ACKNOWLEDGES AND AGREES THAT THIS LIMITED WARRANTY IS GIVEN ONLY TO THE BUYER AND IS NOT TRANSFERABLE OR ASSIGNABLE, IN ANY MANNER WHATSOEVER, TO PERSON OR ENTITY WHO RECEIVES THE PRODUCT (BY PURCHASE OR OTHERWISE) FROM BUYER. LIMITATION ON LIABILITY TO BUYER’S CUSTOMERS: Buyer agrees to limit liability to its customers to the fullest extent permitted by law pursuant to a written contract between Buyer and each end user for whom a DMP product is provided. Buyer acknowledges that DMP shall only be deemed to give consumers of its products such statutory warranties as may be required by law and at no time shall Buyer represent to its customers and/or users of DMP’s products that DMP provides any additional warranties. By accepting the products, to the fullest extent permitted by law, Buyer assumes all liability for and agrees to indemnify and hold DMP harmless against and defend DMP from, any and all suits, claims, demands, causes of action and judgments relating to damages, whether for personal injury or to personal property, suffered by any person, firm, corporation or business association, including but not limited to, Buyer’s customers and/or users of the products because of any failure of the products to detect and/or warn of the danger for which the products were designed or any other failure of the products whether or not such damages are caused or contributed to by the sole or joint negligence or fault of DMP. RETURN AND REPAIR POLICY: Written approval must be obtained from DMP prior to return of any product purchased from DMP whether for repairs, credit or otherwise. A Return Merchandise Authorization (RMA) tag must accompany each item returned. The RMA number must appear on the package and shipping charges must be prepaid. Products returned for credit must be in the original, unopened packaging. All DMP manufactured products returned for credit must be returned within 60 days from date of purchase (30 days for OEM products) with proof of purchase. A 15% restocking charge will be made on all returned products. No products will be accepted for credit after 60 days. Repair charges will be applied to all products returned for repair after the warranty period has expired at DMP’s then prevailing rates. DMP shall not be obligated to repair or replace any products that have been abused, improperly installed, altered or otherwise misused and is not obligated to repair or replace any product that is discontinued, obsolete or that repair parts are no longer available for. All products must be returned to Springfield, Missouri, freight prepaid. DMP will return repaired or replaced products to Buyer UPS Ground at DMP’s expense. If for some reason Buyer desires a faster method of shipping then Buyer agrees to pay the difference in freight charges. Circuit boards only (no cabinets) are to be returned for repair unless it is determined there is a defect in the actual cabinet supplied. As an authorized representative of the applicant, I acknowledge and accept the terms and conditions of the account to be opened in our behalf. As a condition of opening and maintaining the account, I authorize the release of appropriate credit information, as needed and reasonable and periodic credit inquiries with the references furnished. GOVERNING LAW: DMP shall be entitled to charge and recover from Buyer all costs and expenses reasonably incurred in the collection of any amount due hereunder by Buyer, including collection agency fees and charges and reasonable attorney fees and court costs in the event an account is placed with a collection agency or any other action or proceeding is initiated for collection of any such amount due by Buyer (collectively "Collection Expenses"). All orders shall be construed and governed by the laws of the State of Missouri, AND VENUE IN ANY LITIGATION PURSUANT TO ORDERS SUBJECT TO THIS AGREEMENT SHALL BE IN GREENE COUNTY, MISSOURI. EXCUSE OF PERFORMANCE: DMP shall not be liable for delays in performance or for non-performance due to acts of God, inclement weather, war, riot, fire, labor trouble (including labor shortages), unavailability of materials or components, insufficient production capacity, explosion, accident, compliance with governmental requests, laws, regulations, orders or actions, or other unforeseen circumstances or causes beyond DMP's reasonable control. NOTICE: Any notice to a party under this Agreement shall be in writing and shall be served upon the recipient by personal service, or by mailing a copy of such notice by certified mail, postage prepaid, with return receipt requested, if to DMP to: Digital Monitoring Products, Inc., 2500 N. Partnership Boulevard, Springfield, MO 65803, and if to Buyer, at the address shown above. FCC REGULATIONS: DMP offers products which use radio frequencies whose use is governed by the Federal Communications Commission (FCC). The FCC provides you the right to use these products per applicable FCC rules and regulations. DMP is neither responsible nor liable for any cost incurred by Buyer due to changes in FCC rules and regulations, interference or other radio transmissions which may preclude the effective use by the buyer of the assigned frequencies. 155 FAX: 800.743.5724 CUSTOMER SERVICE: 866.266.2826 156 2W-BLX..................................... 112 2WT-BLX................................... 112 263C........................................... 140 263C/263H................................... 27 263C/263H SPEC........................ 27 263H........................................... 140 270............................................. 104 277............................................. 104 300............................................. 115 300-5.......................................... 101 300-12........................................ 101 300-512...................................... 101 300-7800-5................................ 101 300-7800-12.............................. 102 300-9800-4................................ 102 301............................................. 115 302............................................. 115 303............................................. 115 305............................................. 115 306............................................. 115 307............................................. 115 307-S......................................... 115 308............................................. 115 309............................................. 116 310............................................. 116 311............................................. 116 312/25........................................ 116 318............................................. 109 318EXT....................................... 109 318R........................................... 109 318T........................................... 109 319............................................. 116 320............................................. 110 321............................................. 110 322............................................. 111 323............................................. 111 324............................................. 111 324P........................................... 111 325............................................. 111 327............................................. 111 330............................................. 116 332............................................... 91 333............................................... 91 335............................................. 116 340............................................... 85 341............................................... 85 349............................................... 86 349S............................................. 86 350............................................... 86 350A............................................. 86 350B............................................. 86 350C............................................. 86 350D............................................. 86 350S............................................. 88 351............................................... 88 352S............................................. 88 352X............................................. 88 353............................................... 88 354............................................... 88 354A............................................. 88 356............................................. 116 357............................................. 116 357-X......................................... 118 358............................................. 118 364............................................. 109 365............................................. 109 366............................................. 110 368............................................. 110 369............................................. 110 370............................................. 104 370RJ......................................... 104 371-500...................................... 102 372-500........................................ 84 374............................................. 118 376............................................. 112 376L........................................... 112 378............................................. 112 380-400...................................... 142 381............................................. 142 383............................................. 143 386............................................. 143 387............................................. 143 387-1.......................................... 143 387-2.......................................... 143 387-3.......................................... 143 388............................................. 138 390............................................. 118 393............................................. 118 394............................................. 118 395............................................. 138 397............................................. 118 398............................................. 118 399............................................. 119 400............................................. 119 431............................................. 119 505-12........................................ 110 505-12LX................................... 110 572............................................. 119 630F........................................... 101 635............................................. 101 635F........................................... 101 694............................................. 102 695............................................. 102 695-7800................................... 102 696............................................. 102 697............................................. 102 698............................................. 102 698-7800................................... 103 699............................................. 103 699-7800................................... 103 708............................................. 106 710............................................. 106 711............................................. 106 712-8.......................................... 106 714............................................. 106 714-8.......................................... 106 714-16........................................ 107 714-18T..................................... 107 714-19T..................................... 107 714-X......................................... 107 715............................................. 107 715-8.......................................... 107 715-18T..................................... 107 715-20T..................................... 107 716............................................. 108 717............................................. 108 718T........................................... 108 719T........................................... 108 721T........................................... 108 734............................................... 91 734N............................................ 91 734N/734N-WIFI SPEC............. 49 734N-WIFI................................... 91 736P........................................... 108 738A........................................... 108 738I............................................ 108 738Z........................................... 109 738Z SPEC.................................. 67 777............................................. 103 780............................................. 103 850-AR...................................... 113 850D........................................... 113 850D/711................................... 113 850S........................................... 114 850S/711................................... 114 850-SB....................................... 114 850-WP...................................... 114 860............................................. 104 861............................................. 104 865............................................. 104 866............................................. 104 867............................................. 104 869............................................. 106 893A........................................... 106 1076C......................................... 120 1085TW...................................... 120 1100D......................................... 126 1100DH...................................... 126 1100DI........................................ 126 1100R......................................... 126 1100 SERIES SPEC.................... 51 1100X......................................... 126 1100XH...................................... 126 1101........................................... 126 1102........................................... 127 1103........................................... 127 1106........................................... 127 1107........................................... 127 1114........................................... 127 1116........................................... 127 1118R......................................... 127 1119........................................... 129 1121........................................... 129 1125........................................... 129 1126........................................... 129 1127C......................................... 129 1127W........................................ 129 1129........................................... 129 1131........................................... 129 1135........................................... 129 1135-W...................................... 129 1139........................................... 130 1141........................................... 130 1142........................................... 130 1142BC...................................... 130 1145-1-B................................... 130 1145-2-B................................... 130 1145-4-B................................... 130 1148-G....................................... 130 1161........................................... 131 1162........................................... 131 1164-W...................................... 131 1165........................................... 131 1165H......................................... 131 1165HS...................................... 131 1183-135F................................. 131 1183-135R................................. 131 1184........................................... 131 1301........................................... 138 1351............................................. 90 2205A......................................... 120 2207A......................................... 120 2505A......................................... 120 3012........................................... 119 3045........................................... 120 5709C......................................... 123 5812A......................................... 123 5820A......................................... 123 7000............................................. 98 7060............................................. 97 7060A........................................... 96 7060N.......................................... 97 7063............................................. 97 7063A........................................... 96 7063AN........................................ 96 7070............................................. 97 7070A........................................... 96 7070AN........................................ 96 7073............................................. 97 7073A........................................... 96 7073ANEE................................... 96 7160............................................. 98 7163............................................. 98 7173............................................. 98 7360........................................... 100 7363........................................... 100 7872........................................... 100 7872-W/DEMO.......................... 100 7873........................................... 100 9060............................................. 95 9060-W/699................................ 95 9063............................................. 95 9862........................................... 100 ACCESSORY PACK.................. 119 ACCOUNT GROUPS................. 139 AD-0002.................................... 144 AD-0003.................................... 144 AD-0009.................................... 144 AD-0012.................................... 144 AD-0019-TAN........................... 144 AD-0026.................................... 144 ADVANCED REPORTING........ 139 ALARM MONITORING............. 139 CD-0007..................................... 150 CELLCOMSLC........................... 142 CELLCOMSLCF........................ 142 CELLCOMSLCZ........................ 142 CELLCOM SPEC......................... 39 COMMAND CENTER................ 139 CR123........................................ 132 CR123-FIRE.............................. 132 CR2032...................................... 132 CR2430...................................... 132 CR2450...................................... 132 CR17450.................................... 132 CX-702....................................... 125 DESIGNER KEYPADS................ 99 DIGITAL CELL COMM................ 35 DMP AFFINITY PROGRAM..... 145 DX-40......................................... 125 DX-60......................................... 125 ENTRE BUS................................ 94 ENTRE CS................................... 94 ENTRE ENT................................. 94 ENTRE LITE................................ 94 ENTRÉ SPEC.............................. 73 ES501........................................... 88 ES502........................................... 88 ES531......................................... 132 ES532......................................... 132 EX-35T....................................... 125 FG-730....................................... 123 FIRE PANEL SPEC.................... 31 FREE FREIGHT......................... 105 FX-360....................................... 125 GP-23......................................... 120 GRAPHIC SPEC.......................... 45 HID............................................... 93 HSC-1........................................ 121 HSC-BRACKET......................... 120 HUB-M...................................... 123 HUB-T........................................ 123 ICOMSL..................................... 140 ICOMSLF................................... 140 ICOMSLZ................................... 140 KWIKSET AD............................ 134 LINK SERVER........................... 138 LT-0600..................................... 146 LT-0873..................................... 145 LT-0876..................................... 145 LT-0877..................................... 145 LT-0879..................................... 145 LT-0889..................................... 145 LT-0927..................................... 146 LT-0928..................................... 146 LT-0931..................................... 145 LT-0933..................................... 145 LT-0959..................................... 145 LT-0993..................................... 146 LT-1022..................................... 146 LT-1040..................................... 146 LT-1054..................................... 146 LT-1064..................................... 147 LT-1065..................................... 147 LT-1079..................................... 147 LT-1084..................................... 147 LT-1086..................................... 147 LT-1093..................................... 147 LT-1094..................................... 147 LT-1124..................................... 147 LT-1140..................................... 148 LT-1183-1................................. 148 LT-1184-1................................. 148 LT-1190..................................... 148 LT-1258..................................... 148 LT-1262..................................... 148 LT-1263..................................... 148 LT-1267..................................... 148 LT-1284..................................... 149 LT-1285..................................... 149 LT-1296..................................... 149 LT-1305..................................... 149 LT-1311..................................... 149 LT-1362..................................... 149 LT-1365..................................... 149 LT-1375..................................... 150 LT-1381..................................... 150 LT-4100..................................... 150 LT-4150..................................... 150 MET-44WG-18.......................... 121 MOBILE PLATFORMS............... 59 MP-5365...................................... 92 MX-40........................................ 125 MX-5375...................................... 92 MYVIRTUALKEYPAD.COM........ 63 OP-08C........................................ 91 P2S-001..................................... 121 PA-450PI................................... 125 PANEL PACK........................... 119 PB-2............................................. 91 PB-52TC.................................... 121 PP-6005B.................................... 92 PR-5455...................................... 92 PSD100...................................... 120 REMOTE LINK.......................... 138 RP-44......................................... 125 RX-40PI..................................... 126 SCS-1R NETWORK.................. 136 SCS1R-SPARES....................... 137 SCS-1R SPEC............................. 79 SCS-104.................................... 136 SCS-105.................................... 136 SCS-110.................................... 136 SCS-120.................................... 136 SCS-130.................................... 136 SCS-150.................................... 136 SCS-186T.................................. 137 SCS-203.................................... 137 SCS-204.................................... 137 SCS-206.................................... 137 SCS-208.................................... 137 SCS-CTM................................... 139 SCS-RACK................................ 137 SCS-VR...................................... 138 SCS-VR SPEC............................. 81 SD-70......................................... 121 SD205........................................ 139 SM-20WG.................................. 121 SQL DATABASE MODULE...... 139 STB-10...................................... 121 SYSTEM LINK........................... 138 TAKEX AD................................. 128 TANE 60.................................... 121 TANE ALARM AD.................... 124 TANE WS1................................ 121 TECH NOTEBOOK.................... 150 TERMS AND CONDITIONS..... 156 THIN-ICON................................ 100 THINLINE KEYPADS................. 41 THINLINE SPEC......................... 41 THIN-NBRKEYS......................... 98 THIN-SCKEYS............................ 98 TL-5395....................................... 92 V-4010B-1................................. 135 V-4020C-1................................. 135 V-4030PT-1............................... 135 V-4050D-1................................. 135 VIDEO PRODUCTS SPEC.......... 71 V-IP1006RR.............................. 135 XR100.......................................... 85 XR100FC...................................... 85 XR150.......................................... 85 XR150FC...................................... 85 XR150 SERIES FIRE................... 90 XR150 SPEC................................ 17 XR500.......................................... 85 XR500FC...................................... 85 XR550.......................................... 85 XR550FC...................................... 85 XR550 SERIES FIRE................... 90 XR550 SPEC................................ 21 XT30............................................. 84 XT30 PANEL PACKAGES.......... 89 XT50............................................. 84 XT50 PANEL PACKAGES.......... 89 XTLC............................................ 84 XTL DEMO SYSTEM................... 84 XTLN............................................ 84 XTLN-WIFI.................................. 84 XTL SERIES SPEC....................... 7 XT SERIES SPEC........................ 11 Z-5010T..................................... 133 Z-45602..................................... 133 Z-45603..................................... 133 Z-45740..................................... 133 Z-45741..................................... 133 Z-45742..................................... 135 Z-99100..................................... 132 Z-99100-STAND....................... 133 Z-99140..................................... 132 Z-99160..................................... 133 Z-GD00Z-4................................ 133 Z-LB60Z-1................................. 135 COST OF CREATION MINIMAL Update all your outdated 2G & POTS systems quickly and affordably. The CellComSLTM provides a simple upgrade for ANY PANEL, adds interactive or Z-Wave® services for minimal investment but multiple return. Learn more at DMP.com/CellComSL ® We make your company more valuable. l 877-725-1114 dmp.com 157 FAX: 800.743.5724 CUSTOMER SERVICE: 866.266.2826 158 O U R VISION Provide every person the opportunity to experience the security of a DMP alarm system. O U R MISSION DMP provides customer-driven products through listening, anticipating needs, and responding quickly with innovative solutions that work. We insist on the integrity of our products and our people. We Care. We Have Fun. We Profit. O U R VALUES HONESTY AND INTEGRITY Tell the truth...even if it costs you something. Do what’s right... especially when no one is watching. Do the right thing because it’s the right thing to do. INNOVATION & INITIATIVE Always be learning. Know the customers, products, competition and new technology. Creative solutions to customer needs is vital to our future. RESPONSIVENESS Anticipate. Listen. Acknowledge. Deliver. The best time to respond is yesterday. The second best time is now. KINDNESS Think before you speak. Consider the feelings of others. Treat all with LT - 0898 02/13 Digital Monitoring Products, Inc. 2500 N. Partnership Blvd Springfield, MO 65803 800.641.4282 dmp.com respect and courtesy, even if delivering an unpleasant message. FUN Work hard. Play hard. Live healthy. Share and celebrate every success. PROFIT Profit is good. It’s why we’re in business. It secures jobs and fuels personal and corporate growth. TEAMWORK Support your team. Be accountable. Ask for help when needed. Believe the intentions and abilities of others are good. GENEROSITY Giving is greater than receiving. Serve others with your time. Serve others with your money. Giving to others leads to personal fulfillment and happiness. APPEARANCE Appearance matters. Neatness counts. Attention to detail, organization and professional appearance reflect our commitment to excellence. 159 FAX: 800.743.5724 CUSTOMER SERVICE: 866.266.2826 160
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement