Installation Instructions
Radionics
™
D9650T Passive Infrared Motion
Detector with POPIT Interface
1.0 Specifications
• Input Power: Connect to the Zonex Bus of the control panel.
• Current Draw: Less than 500 micro-amps. Two milli-amps when
in walk test mode (LED on).
• Standby Power: There is no internal standby battery. Connect to
DC power sources capable of supplying standby power if primary
power fails. 500 micro-amp-hours required for each hour of
standby time needed. Four hours minimum is required for U. L.
Listed Requirements.
• Coverage:
Standard Broad
50 ft. by 50 ft.
(15 m by 15 m)
Barrier (Optional)
80 ft. by 16 ft.
(24.4 m by 4.8 m)
Long Range (Optional) 120 ft. by 10 ft. (36.6 m by 3.1 m)
• Sensitivity: Standard, Intermediate, or High.
• Tamper: A tamper condition is signaled through the Zonex Bus
and displayed at the keypads when the cover is removed.
• Temperature: The storage and operating range is -20° to +120°F
(-29° to +49°C). For U. L. Listed Requirements, the range is +32°
to +120°F (0 ° to +49° C).
• Requirements: Compatible Radionics control panel with POPEX
module installed.
• Options: B328 Gimbal Mount Bracket, B335 Low Profile Swivel
Mount Bracket, OMB77-3* Barrier Mirror, OMLR77-3* Long
Range Mirror, and the TC6000 Test Cord.
* Shipped in packages of 3.
Note: Misalignment of the detector when using an optional
mounting bracket may reduce range.
• U. S. Patent Numbers: # 4,764,755 and #5,083,106.
2.0 Multiplex Programming
Program the address DIP switches as described for the control
panel you are using.
Note: When installing the D9650T with a D7212B1, D8112,
D9112B1, D9412, or D9112; place switch number “0” in the
ON position.
Recommended point type programming =
• The recommended mounting height range is 6.5 ft. to 8.5 ft. (2 m
to 2.6 m).
Note: The mounting surface should be solid and vibration free.
Things to Avoid/Remember
Avoid
Direct hot and/or cold drafts. Windows. Small animals.
Air conditioning outlets. Heat sources. Direct sunlight.
Remember
Won’t detect through glass. Best catch performance
is across the pattern. When using two or more
detectors, cross patterns for best coverage.
• Remove the cover. Insert a thin flathead screwdriver into the
notch at the bottom of the cover and pry up.
• Remove the circuit board/mirror unit from the enclosure. Push the
board/mirror unit toward the top of the enclosure until it clears its
four retainer tabs, then lift it out.
• Open the knock-out wire entrance and route the wiring through.
Surface or Corner Mounting
• Open 2 holes for surface or corner mounting.
• Mark the location for the mounting screws. Use the enclosure as
a template. Pre-start the mounting screws.
• Firmly mount the detector.
• Replace the circuit board/mirror unit.
Select the Vertical Angle
The angle adjust markings
are on the mirror. Slide the
mirror forward or back until
the angle hash marks are inline with the markers on each
side of the frame.
+2
0
-8
-16
Mirror
This chart will help you set the correct Vertical Angle based on the
mounting height, mirror type, and desired range.
• D8112 = 6571
• D9112B1/D7212B1 = Point type 2, point response 2, no ring until restored.
• D9412/D9112 = Point type 2, point response E, no ring until restored.
3.0 Mounting
• Select a location that is most likely to intercept an intruder moving
across the coverage pattern.
Mounting
Height
Broad
Barrier
30(9) 50(15) 50(15) 80(25)
Long Range
80(25)
120(36)
6.5(2)
-6°
-3°
-3°
-2°
-2°
-1°
7.5(2.3)
-8°
-5°
-5°
-3°
-3°
-2°
8.5(2.6)
-9°
-6°
-6°
-4°
-4°
-2°
Height and desired Range listed in feet (meters)
4.0 Wiring
1
T-Strip
2
1
0123456
Address Switches
Program Plugs
LED
Sens
Motion
Do not use
3
Noise
Voltage
LED
Tamper Switch
1
2
1
Location of major items - Circuit Board
1 = Corner 2 = Surface 3 = Bracket
Rear enclosure and mounting holes
P/N 31441C
CAUTION: Only apply power after all connections have been
made and inspected.
• Connect wiring as shown.
Terminal Descriptions
• 1 (+), 2 (+), 3 (-), & 4 (-):
Connect to the Zonex Bus
of the control panel. Use no
smaller than #22 AWG (0.8
mm) wire between the
detector and the control
panel.
D9650T Installation Instructions
Page 1
POPEX MODULE
–
–
+
+
(+)
(–)
1
2
3
ZONE EXPANSION
LOOP TO OTHER
POINTS
4
+ + - -
IN OUT IN OUT
© 1996 Radionics
5.0 Program Jumpers
The following functions are controlled by various settings of the
program jumpers:
ON
(Default)
• LED Operation:
OFF
- ON: Allows the
STD
INT
LED Jumpers
30 Days
LED to operate
HIGH
Standard (Default)
when activated by
STD
4 Days
alarm.
INT
HIGH
- OFF: The LED
Intermediate
will not operate on
OFF
STD
(Default)
INT
alarm.
HIGH
Motion Monitor
High
Jumpers
• Sensitivity Mode:
Sensitivity
Jumpers
- Standard:
The recommended setting for maximum false alarm immunity.
Tolerates environmental extremes on this setting. Not recommended for Long Range or Barrier type patterns. The detector is
shipped in Standard Sensitivity mode.
- Intermediate: The recommended setting for any location where
an intruder is expected to cover only a small portion of the
protected area. Tolerates normal environments on this setting.
This setting will improve your intruder catch performance.
- High: The setting for fast response to intruder signals. For use in
quiet environments where thermal and illumination transients are
not anticipated.
• Motion Monitor:
- Set for the desired Motion Monitor time (see Section 8.0
Supervision Features). The detector is shipped with the Motion
Monitor jumper in the OFF position.
once during the selected time period (this feature can be disabled
by placing the Motion Monitor plug in the OFF position). The time
period selected should be long enough to allow adequate time for
holiday weekends.
9.0 Other Information
• Maintenance: At least once a year, the range and coverage
should be checked in accordance with the Walk Testing section.
To ensure continual daily operation, the end user should be
instructed to daily walk through the outer edge of the coverage
pattern. This assures an alarm output prior to arming.
• Sealing the wire entrance: The foam plug provided is used to
seal the wire entrance from drafts and insects after installation.
• Mirrors: The mirror is adjustable +2° to -18° vertically and +10° to
-10° horizontally. To change the mirror, just pull it out from its
resting grooves.
Note: Excessive handling of the mirror surfaces may lead to
performance degradation.
10.0 Coverage Patterns
Broad Coverage
Top View
25
0 Meters
15
A
B
O P Q
7.5
C
J
F
e
e
t
6.0 Setup and Walk Testing
O
P
0
Q
D
K
E0
L
M
• Apply power to the unit.
F
N
M
e
t
e
r
s
J K L M N
A B C DE FG H I
G
• Wait approximately 3 minutes (with no motion
in the coverage area) for the detector to setup.
• Walk test across the coverage pattern.
• The edge of the coverage is determined by
activation of the LED.
• Walk test the unit from both directions to determine the boundaries.
25
F 10
e
e 5
t 0
0 Meters
15
0 Feet
O-Q
7.5
J-N
A-I
50
M
e
t
e
r
s
3
0
Mirror adjusted to -3°
10
F
e
e
t
0 Meters
K
I
0
L J
10
• The base reference level for reading back-W
ground noise is approximately 2.0 VDC.
+R
- Installations in quiet environments will result
-B
TC6000
in a steady meter reading between 1.9 and
2.1 VDC.
- Voltage changes greater than 0.75 VDC from the reference level
are desirable for good catch performance.
- If changes are less than +0.75 VDC, the device may fail to
respond if the temperature between the intruder and the
background is minimal.
• Turn on all heating and cooling sources that would normally be in
operation during times of protection.
- Stand away from the unit and outside the coverage pattern, then
monitor the background noise for at least three minutes.
- Readings should not deviate from the reference level more than
±0.15 VDC.
- For readings outside these limits; eliminate the cause, re-point
the unit slightly, or mask off the affected zones.
50
Side View
7.0 Final Tests
• Connect a DC VOM to the Noise Voltage pins.
- Set meter scale for about 5.0 VDC (use of
the TC6000 is recommended).
H
I
0 Feet
Barrier Coverage
Top View
25
G
H
C
E
F
3
A
D
0
B
3
80
0 Feet
Side View
0Meters
25
F 10
e
e 5
t 0
3
0
0 Feet
K-L I-J G-H E-F
80
M
e
t
e
r
s
• PIR: The PIR operation is verified electronically approximately
every 12 hours. If the circuit fails, the LED will pulse 4 times per
cycle and the trouble output will activate through the Zonex Bus.
If the PIR operation fails, the detector must be replaced.
• Motion Monitor Supervision: This feature verifies that the
detector has a clear view of the detection area.
When selected, a supervision timer is activated. A trouble
condition will be indicated if the detector has not alarmed at least
E
G
H
F
C
D
A
B
A-B
C-D
Mirror adjusted to -2°
Long Range Coverage
Top View
F5
e
e 0
t 5
0 Meters
40 1.5 M
0
1.5
120
0 Feet
e
t
e
r
s
Side View
F 10
e
e
t 0
0 Meters
40
3
0 Feet
E D
C
B
Mirror adjusted to -1°
8.0 Supervision Features
K L J
I
M
e
t
e
r
s
A
0
120
M
e
t
e
r
s
C D E
B
A