- Computers & electronics
- Audio & home theatre
- Video switches
- Altronix
- HUBWAYLD82CD
- Installation manual
Altronix HUBWAYLD82CD Installation manual
Add to my manuals8 Pages
Altronix HUBWAYLD82CD is an active UTP transceiver hub with integral camera power that provides transmission of video, data, and power over a single CAT-5 or higher structured cable. It offers 8 camera channels in a space-saving 1U EIA 19” rack-mount chassis and allows for rack, wall, or shelf mounting.
The HUBWAYLD82CD features video transmission range of up to 3000 ft. per channel and is compatible with AC and/or DC fixed or PTZ cameras when using Altronix HubWayAv, HubWayAv2, HubWayDv, or HubWayDvi video balun/combiners.
In addition to its video capabilities, the HUBWAYLD82CD provides individually selectable 24VAC or 28VAC power outputs with PTC protection and surge suppression. Its illuminated master power disconnect circuit breaker with manual reset ensures safe operation and easy troubleshooting.
advertisement
Video • Data • Power
Active UTP Transceiver Hubs with Integral Camera Power
Installation Guide
Models Include:
HubWayLD8CD HubWayLD16CD
- UL Listed eight (8) Channel Active UTP
Transceiver Hub with Integral Camera Power
- UL Listed sixteen (16) Channel Active UTP
Transceiver Hub with Integral Camera Power
HubWayLD82CD HubWayLD162CD
- UL Listed eight (8) Channel Active UTP
Transceiver Hub with Integral Camera Power
- Includes eight (8) UL Listed Accessory
HubWayAv Video Balun/Combiners
- UL Listed sixteen (16) Channel Active UTP
Transceiver Hub with Integral Camera Power
- Includes sixteen (16) UL Listed Accessory
HubWayAv Video Balun/Combiners
HubWayLD83CD HubWayLD163CD
- UL Listed eight (8) Channel Active UTP
Transceiver Hub with Integral Camera Power
- Includes eight (8) UL Listed Accessory
HubWayDv Video Balun/Combiners
- UL Listed sixteen (16) Channel Active UTP
Transceiver Hub with Integral Camera Power
- Includes sixteen (16) UL Listed Accessory
HubWayDv Video Balun/Combiners
More than just power.
TM Rev. 030408
Overview:
Altronix HubWayLD8CD/LD16CD Active UTP Transceiver Hubs with Integral Camera Power transmits UTP video,
RS422/RS485 data and power over a single CAT-5 or higher structured cable. Units provides 8 or 16 camera channels in a space saving 1U EIA 19” rack mount chassis which may be rack, wall or shelf mounted. Video transmission range is up to 3000 ft. max. per channel. Units are compatible with AC and/or DC fixed or PTZ cameras when utilizing Altronix
HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Video Balun/Combiners. In addition, the unit features individually selectable 24VAC or 28VAC PTC protected outputs with surge suppression. An optional HubSat4D Passive UTP
Transceiver Hub with Integral Camera Power can be used as an accessory module to transmit video from up to 4 cameras over a single CAT-5 or higher structured cable back to the HubWayLD8CD/LD16CD. In addition, the HubSat4D provides power to these cameras locally to eliminate the possibility of voltage drop associated with long cable runs.
HubWayLD Specifica tions:
HubWayLD8CD/LD82CD/LD83CD
Input:
• 115VAC 60Hz, 1.5 amp.
Video:
• Eight (8) channels of video over twisted pair up to
a distance of 3000 ft. per channel.
• Eight (8) 75 ohm video outputs.
Power:
• Unit provides up to 1 amp max. per channel not to
exceed a total of 5 amp (150VA) maximum current.
HubWayLD16CD/LD162CD/LD163CD
Input:
• 115VAC 60Hz, 3 amp.
Video:
• Sixteen (16) channels of video over twisted pair up to
a distance of 3000 ft. per channel.
• Sixteen (16) 75 ohm video outputs.
Power:
• Unit provides up to 1 amp max. per channel not to
exceed a total of 10 amp (300VA) maximum current.
Agency Listings:
• UL Listed for Commercial CCTV Equipment (UL 2044).
CUL Listed - CSA Standard C22.2 No.1-04, Audio,
Video and Similar Equipment.
Data:
• RS422/RS485 data inputs.
Power:
• Individually selectable 24VAC or 28VAC power outputs
with OFF position.
• PTC protected output are rated @ 1 amp per channel.
• Surge suppression.
Visual Indicators:
• Individual video signal LED indicators.
• Individual power LED indicators.
Common Specifica tions:
Features:
• Picture and Gain control.
• Illuminated master power disconnect circuit breaker
with manual reset.
• IEC 320 - 3-wire grounded line cord (detachable).
• Unit can be rack, wall or shelf mounted.
• 1U rack mount chassis for use in standard EIA 19” rack.
Accessories:
• Video Balun/Combiners:
- HubWayAv - for use with 24VAC cameras.
- HubWayAv2 - for use with 24VAC cameras.
- HubWayDv - for use with 12VDC cameras.
- HubWayDvi - for use with non-isolated 12VDC cameras.
• Optional HubSat4D allows transmission of up to
four (4) video signals over a single CAT-5 or higher
structured cable.
Additional Models:
HubWayLD82CD
• HubWayLD8CD with eight (8) UL Listed Accessory
HubWayAv Video Balun/Combiners for 24VAC
Cameras.
HubWayLD83CD
• HubWayLD8CD with eight (8) UL Listed Accessory
HubWayDv Video Balun/Combiners for 12VDC
Cameras.
HubWayLD162CD
• HubWayLD16CD with sixteen (16) UL Listed Accessory
HubWayAv Video Balun/Combiners for 24VAC
Cameras.
HubWayLD163CD
• HubWayLD16CD with sixteen (16) UL Listed Accessory
HubWayDv Video Balun/Combiners for 12VDC
Cameras.
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture.
This installation should be made by qualified service personnel and should conform to all local codes.
- 2 - HubWayLD Active Unit
Installation Instructions:
1. Attach mounting brackets to HubWayLD8CD/LD16CD unit for rack or wall mount installation (Figs. 6a-6b, 7a, pg. 8).
Affix rubber pads to HubWayLD8CD/LD16CD for shelf installation (Fig. 8, pg. 8).
2. Secure the unit in a rack, mount unit to a wall or place unit on a shelf as desired (unit should be spaced at least 3” from any video monitors) (Figs. 6c, 7b, pg. 8).
3. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 5, pg. 7).
4. Plug the grounded AC line cord (included) into the IEC 320 connector of the HubWayLD8CD/LD16CD
(Fig. 1j, pg. 4). Insert the plug end of the line cord into a grounded 115VAC receptacle.
5. Set voltage output selector switch for each camera channel for 24VAC or 28VAC (Fig. 1d, pg. 4).
6. Connect the BNC video outputs for HubWayLD8CD/LD16CD Channels 1 - 8 (Channels 1-16) to the corresponding video inputs on the head end equipment (DVR) (Fig. 1f, pg. 4).
7. Connect the RS422/RS485 output of the head end equipment (DVR) to the one (1) or both data input terminal blocks of the HubWayLD8CD/LD16CD unit (polarity must be observed) (Fig. 1e, pg. 4).
Note: The Data input terminals of the HubWayLD8CD/LD16CD must be wired in parallel for proper operation. When using fixed cameras disregard this step.
8. Connect Video Balun/Combiner at camera 1 to the HubWayLD8CD/LD16CD unit utilizing CAT-5 or higher structured cable. Plug the RJ45 connector at one end of the structured cable into the RJ45 jack marked [Channel 1] of the
(Fig. 1a, pg. 4). Plug the RJ45 connector at the opposite end of the structured cable into the RJ45 jack of the Video Balun/Combiner located at camera 1.
• For 24VAC cameras use Altronix model HubWayAv/HubWayAv2 Video Balun/Combiner (Figs. 2a, 2b, 2e, pg. 5).
• For 12VDC cameras use Altronix model HubWayDv Video Balun/Combiner (Figs. 2c, 2d, pg. 5).
• For non-isolated 12VDC cameras use Altronix model HubWayDvi Video Balun/Combiner (Figs. 2c, 2d, pg. 5).
Repeat steps 6-8 for each additional camera (Channels 2-8 or Channels 2-16).
Note: When a particular camera exceeds the maximum distance for power transmi ssion, a local external power source is required. Optionally, an Altronix HubSat4D Passive UTP Transceiver Hub with Integral Camera Power may be
(Fig. 4a, pg. 6). The combined total cable distance for video transmission must not exceed 3000 ft. between the HubWayLD8CD/LD16CD and each camera routed through the HubSat4D.
9. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 5, pg. 7) and measure the output voltage at the power output terminals of each Video Balun/Combiner (Figs. 2b, 2d, pg. 5) before powering each camera to ensure proper operation and avoid possible damage.
• HubWayAv/HubWayAv2 - Terminals marked [AC POWER] (Figs. 2a, 2b, 2e, pg. 5).
• HubWayDv/HubWayDvi - Terminals marked [– 12VDC +] (Figs. 2c, 2d, pg. 5).
10. Set illuminated master power disconnect circuit breaker to the (OFF) position to make the final connections (Fig. 5, pg. 7).
11. Connect the power outputs of the HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Video Balun/Combiners to the power inputs of the cameras (Figs. 2a-2e, pg. 5). Polarity must be observed.
12. Connect the terminals marked [+ DATA -- ] of the HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Video
Balun/Combiners to the data terminals of the cameras for PTZ control (Figs. 2a-2e, pg. 5). Polarity must be observed.
When installing fixed cameras disregard this step.
13. Connect the BNC connectors of the HubWayAv, HubWayAv2, HubWayDv or HubWayDvi Video Balun/Combiners to the BNC video outputs of the cameras (Figs. 2a-2e, pg. 5).
14. Upon completion of wiring set illuminated master power disconnect circuit breaker to the RESET (ON) position
(Fig. 5, pg. 7).
15. The power LEDs (Red) located on the front of the HubWayLD8CD/LD16CD will illuminate when AC power is present (Fig. 1c, pg. 4).
Note: If any of these LEDs are not illuminated either a voltage output selector switch is in the OFF position or the
PTC is tripped for that channel.
To reset the PTC:
1. Set the voltage output selector switch for that corresponding channel to the OFF position. Switch must remain
in the OFF position for approximately 2 minutes in order for the PTC to reset.
2. Eliminate the trouble condition (short circuit or overload).
3. Set the voltage output selector switch for 24VAC or 28VAC (Fig. 1d, pg. 4).
16. AC LEDs (Green) of the HubWayAv or DC LEDs (Red) of the HubWayDv/HubWayDvi Video Balun/Combiners will illuminate indicating power is present at the cameras (Fig. 2b, 2d, pg. 5).
17. The video signal indicator LEDs (Red) located on the rear of the HubWayLD8CD/LD16CD will illuminate when video signal is present (Fig. 1i, pg. 4). If any of these LEDs are not illuminated, no video signal is present for that corresponding channel.
18. Optimize the picture quality for all camera channels by adjusting the corresponding potentiometers marked [Picture] (Fig. 1g, pg. 4).
19. Set gain for all camera channels by adjusting the corresponding potentiometers marked [Gain] (Fig. 1h, pg. 4).
HubWayLD Active Unit - 3 -
terminal blocks for RS422/ RS485 input from head end equipment
Head End Equipment (DVR).
+ --
1j - IEC 320 Connector: 115VAC 60Hz (grounded line cord included).
1d - Voltage Output Selector Switch: 24VAC/28VAC/OFF for each output.
1b - Channels 1-4, Channels 5-8, Channels 9-12 & Channels 13-16: CAT-5 or higher structured cable from optional HubSat4D enables video transmission from up to four (4) cameras.
- 4 -
1a - Channels 1-8 (HubWayLD8CD) or Channels 1-16 (HubWayLD16CD): CAT-5 or higher structured cable to Video/Balun Combiners at cameras 1-8 or 1-16. When using an optional HubSat4D any of these inputs can be utilized for data transmission to PTZ’s
Regulates the output video and sync levels.
Adjusts video quality.
1f - BNC Connector: outputs to head end equipment
HubWayLD Active Unit
HubWayAv, HubWayAv2, HubWayDv, and HubWayDvi Video Balun/Combiners:
Altronix
Model Number
HubWayAv
HubWayAv2
Input Voltage from HubWay
Unit
*24VAC/28VAC
Output Voltage to Camera
*24VAC/28VAC *24VAC/28VAC
*24VAC/28VAC
Camera Type
*24VAC/28VAC
*24VAC/28VAC
Power LED
Green
N/A
HubWayDv *24VAC/28VAC 12VDC 12VDC cameras Red
HubWayDvi *24VAC/28VAC 12VDC electronically isolated 12VDC cameras without isolation Red
*Based on camera load and structured cable length.
Fig. 2
Fig. 2a
VIDEO
Fig. 2c
VIDEO
HubWayAv
VIDEO BALUN/COMBINER
AC
CAT5 + DATA-- POWER
HubWayDv
VIDEO BALUN/COMBINER
CAT5 + DATA-- -- 12VDC+
* Also Available as:
HubWayDvi
Video Balun/
Combiner
for non-isolated
12VDC cameras
RJ45 Jack
Wire
Connectors RJ45 Jack
Wire
Connectors
Fig. 2b Fig. 2d
To BNC
Connector of Camera
Structured
Cable from
HubWay8CD or
HubWay16CD
Green Power LED
AC Power to Camera
--
+
Data to
Camera
To BNC
Connector of Camera
Structured
Cable from
HubWay8CD or
HubWay16CD
Red Power LED
+
--
12VDC Power to Camera
--
+
Data to
Camera
Fig. 2e
HubWayAv2
Cat5 back to
HubWay or
HubSat
Power to Camera
Data to Camera
HubWayAv/HubWayAv2 passes AC voltage from pins
4, 5, 7, 8 to terminals marked [AC Power] (Fig. 3, pg. 5).
Video from Camera
HubWayDv/HubWayDvi converts AC voltage to DC voltage from pins 4, 5, 7, 8 to terminals marked
[-- 12VDC +] (Fig. 3, pg. 5).
Fig. 3 - CAT-5 Structured Cable Wiring Color Codes and PIN Configurations
1 - White/Orange [VIDEO +]
2 - Orange [VIDEO -- ]
3 - White/Green [DATA +]
4 - Blue [AC 1]
5 - White/Blue [AC 2]
6 - Green [DATA -- ]
7 - White/Brown [AC 2]
8 - Brown [AC 1]
HubWayLD Active Unit - 5 -
Typical Applications:
Fig. 4
Head End Equipment (DVR)
RS485
Monitor
Video
Data
Rear
8 7 6 5 4 3 2 1
PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN AC POWER
1 2 3 4 CH 1-4 5 6 7 8 CH 5-8
28VAC
OFF
24VAC
Front
CAT-5
Video
Power
Video
Power
Video
Data
Power
CAT-5
Four (4) Video signals on a single CAT-5
Data
(CAT-5)
CAT-5
Video
Data
Power
Max.
video
3000 ft.
Fixed
Camera
HubWayAv
Video Balun
Combiner
Video
Data
Power
PTZ
Camera
HubWayAv
Video Balun
Combiner
Outdoor
PTZ
Camera
Fixed
Camera
HubWayDv/Dvi
Video Balun
Combiner
Outdoor
NEMA
Rated
Power
Supply
Power
Video
Data
HubWayAv or
HubWayDv/Dvi
Video Balun
Combiner
PTZ
Camera
HubWayDv/Dvi
Video Balun
Combiner
CAT-5
Video
Power
Fixed
Camera
HubWayDv/Dvi
Video Balun
Combiner
24VAC/28VAC
Camera Power
Provided by HubSat4D
115VAC
Input, 50/60Hz
HubWayAv
Video Balun
Combiner
PTZ
Camera
Power
Video (Coax)
Fixed
Camera
Fig. 4a - Optional hookup utilizing HubSat4D.
115VAC Input,
50/60Hz
- 6 - HubWayLD Active Unit
Rack Mount Chassis Mechanical Drawing & Dimensions (H x W x D approximate):
1.625” x 19.125” x 8.5” (41.275mm x 486mm x 215.9mm)
REAR
1.625"
41.28mm
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN PICTURE GAIN
TOP & BOTTOM
17.625"
447.67mm
AC POWER
8.5"
215.9mm
0.75"
19.05mm
FRONT
1 2 3 4 CH 1-4
+ DATA --
1-8
5 6 7 8 CH 5-8
28VAC
OFF
24VAC
19.125"
485.78mm
(ON)
9 10 11 12 CH 9-12
+ DATA --
9-16
13 14 15 16 CH 13-16
28VAC
OFF
24VAC
Fig. 5
Illuminated master power disconnect circuit breaker:
• OFF position Circuit breaker tripped – Switch not illuminated.
• RESET (ON) position – Switch illuminated.
The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open enclosure. There are no user serviceable parts inside. Refer servicing to qualified service personnel.
HubWayLD Active Unit - 7 -
Mounting Options:
Rack Mount Installation
1- Remove and discard factory installed screws from both sides of rack chassis (Fig. 6a).
2- Install mounting brackets (A) on the left and right side of rack chassis using the
four (4) flat head screws (B) (included) (Fig. 6b).
3- Place unit into desired EIA 19” rack position and secure with mounting screws (not included) (Fig. 6c).
Fig. 6
Fig. 6a Fig. 6b Fig. 6c
Top Top Top
Front
Left
Front
Left
Front Left
B
Remove
A
Wall Mount Installation
1- Install mounting brackets (A) on the left and right side of rack chassis using
four (4) flat head screws (B) (included) (Fig. 7a).
2- Place unit at desired location and secure with mounting screws
(not included) (Fig. 7b).
Caution: It is necessary to
make sure mounting screws
Fig. 7
Fig. 7a Fig. 7b
are securely fastened to a
beam when installing the
unit vertically.
B
A
Shelf Installation
1- Position and affix rubber pads (C) (included) at each
corner on the bottom of the unit (Fig. 8).
2- Place unit in desired location.
Fig. 8
Left Side
C
Rubber Pad
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 website: www.altronix.com, e-mail: [email protected], Lifetime Warranty, Made in U.S.A.
IIHubWayLD8CD/LD16CD E21N
- 8 -
Dotted lines indicate studs behind sheetrock.
Mounting Hardware
(Included):
A Two (2) mounting brackets
B
Six (6) flat head screws for mounting brackets.
C Four (4) rubber pads.
MEMBER
HubWayLD Active Unit
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project