Series IMP Temperature Control Module
Athena’s Series IMP Modules use
microprocessor-based circuitry to
perform all required control fuctions.
Units have built-in diagnostics and
are fully self-tuning - setpoint
temperatures are maintained without
the need to manually preset or adjust
the control temperature.
• Simultaneous digital setpoint and digital
temperature indication.
• Available in 15- and 30-amp modules as
well as single-zone 15- and 30-amp
portable temperature controllers.
• Compatible with existing Athena “G+”,
D-M-E “G” Series, D-M-E “Smart”
Series, and other standard mainframes.
• Compu-Step® feature removes moisture
from the heater before full power is
applied.
• Compu-Cycle® feature improves
response time, reduces thermal fatigue
and prolongs heater life by applying
AC power smoothly and continuously.
• Manual control for non-thermocouple
applications, provides standby or
“weekend” heat or to manually control
temperature if a thermocouple fails.
• Diagnostic and protection features
include power “on”, power to load,
manual mode, and over/under
temperature, plus indicators and
system protection for reversed and
open thermocouples.
• SafeChange™ “hot swap” feature
allows safe removal and replacement
of module.
• Available standby heat and alarm
accessory module (SAM) automatically
sets all zones for standby, or “weekend”
heat, and provides visual and audible
alarms for over/under temperature.
308
Model IMPD15
15 Amp
1-11........... $210.00
12+............ $195.00
Model IMPD30
30 Amp ....................... $480.00
1061 Industrial Parkway, Medina, Ohio 44256, U.S.A.
Phone: 330-722-1182 • Toll Free: 800-345-7693
Fax: 330-725-2723 • Toll Free Fax: 800-581-9264
E-mail: [email protected]
ORDER TOLL FREE
1-800-345-7693
ISO 9001
Certified
Company
IMP Series Control Modules
Series IMP Technical Specifications
Performance Specifications
Control Mode
Temperature Range
Temperature Reset
Control Accuracy
Temperature Stability
Calibration Accuracy
Power Response
Time
Compensated
Manual Mode
Over Temperature
Indicator
Under Temperature
Indicator
TC Break Indication
TC Reverse
Indication
No Heat/Open Heater
Indication
CompuStep® System
Control Mode
CompuStep® System
Duration
CompuStep® System
Output Voltage
CompuStep® System
Holding Temperature
CompuStep® System
Override Temperature
CompuCycle® system.
Ambient to 999oF or ambient
to 535oC.
Automatically corrects reset to
within 2oF (1oC) at all settings.
±1.0oF (±0.5oC) dependent on
total thermal system.
±0.5% of full scale over ambient
range of 32 to 140oF (0 to 60oC)
Better than 0.2% of full scale.
Input Specifications
Thermocouple (T/C)
Sensor
External (T/C)
Resistance
T/C Isolation
Cold Junction
Compensation
Input Type
Input Impedance
Better than 0.13 seconds.
Input Protection
Input Amplifier
Maintains constant output power to Stability
within 1% of manually set power
Input Dynamic Range
level with line voltage variation from Common Mode
192 to 264 volts. Power control
Rejection Ratio
range is from 0 to 100%, using the Power Supply
Rejection Ratio
CompuCycle system power drive.
Type “J” , grounded or ungrounded.
Greater than 1000 ohms.
Isolated from ground and supply
voltages.
Automatic, better than 0.02oF/oF
(0.01oC/oC).
Potentiometric.
22 megohms.
Diode clamp, RC filter.
Better than 0.05oF/oF (0.03oC/oC)
Greater than 1000oF (535oC).
Greater than 100 dB.
Greater than 90 dB.
Output Specifications
The upper segment of the leftmost
display will be “on” and the whole
display flashes at about 2 Hz when
the temperature error exceeds
+30oF (+17oC).
Voltages
The lower segment of the leftmost
display will be “on” and the whole
display flashes at about 2 Hz when
the temperature error exceeds
-30oF (-17oC).
Flashing “
“ on the leftmost
display (in closed-loop and
CompuStep).
Overload Protection
Flashing “
“ on the leftmost
display (in closed-loop and
CompuStep).
Flashing “ _____ “ center segment
only of the leftmost display
(in closed loop).
Variable stepping voltage, phase
fired.
Power Capability
Output Switch
Power Line Isolation
Electrical Power Specifications
Input Voltage
Frequency
DC Power Supplies
Module Power Usage
240/120 Vac, +10% - 20%
50 Hz ±3 Hz, 60Hz ±3 Hz.
Internal generated, regulated and
temperature compensated.
Less than 3 watts, excluding load.
Controls And Indicators
Setpoint Control
Manual Power Control
Mode Control
Approximately 5 minutes.
Step approximately from 25VRMS to
170VRMS with 240 Vac line input.
256oF (125oC).
240Vac nominal, single phase 120
Vac availible.
15 amperes, 3600 [email protected] Vac
30 amperes, 7200 [email protected] Vac.
Internal solid state triac, triggered by
ac zero crossing pulses.
Triac and load use high speed fuses.
Both sides of ac line are fused.
Optically and transformer isolated
from ac lines. Isolation voltage is
greater than 2500 volts.
Power ON/OFF
Precision 3 digit pushbutton switch,
direct reading; Range: 0 to 999oF
(535oC); Resolution: 1oF (1oC);
Accuracy: Better than 0.5oF(0.3oC)
Single turn potentiometer, calibrated
scale; Range: 0-100%; Linearity: 10%
3-position sliding switch selects
mode of operation:
1. top position - manual mode,
2. middle position - auto mode,
3. bottom position - auto mode with
CompuStep system.
Rocker switch, UL,CSA,VDE
approved.
200oF (93oC).
1061 Industrial Parkway, Medina, Ohio 44256, U.S.A.
Phone: 330-722-1182 • Toll Free: 800-345-7693
Fax: 330-725-2723 • Toll Free Fax: 800-581-9264
E-mail: [email protected]
ORDER TOLL FREE
1-800-345-7693
309
ISO 9001
Certified
Company
RMA Series Control Modules
Series RMA Temperature Control Module
The Athena Series RMA is a
microprocessor-based,
single-zone temperature controller
specifically designed for
runnerless molding applications.
It features an easy-to-use
operator keypad, two LED
displays, and discrete
indicators for heat output,
alarm, F/C indication, manual
and closed loop mode.
• Compatible with industry standard
control modules and mainframes.
• Accepts Type J thermocouple.
• Bumpless auto/manual transfer.
• Compu-Step® bakeout feature
prevents moisture at startup.
• Built-in loop break for open heater,
shorted triac, reversed or shorted
thermocouple.
• Open thermocouple break protection
with jumper-selectable shutdown or
average power output based on
operation.
• Preset alarms at 30oF (17oC).
• SafeChange™ “hot swap” feature
allows safe removal and
replacement of module.
• CE-compliant.
15 Amp
Model RMAD15
1-11........... $165.00
12+............ $160.00
Lowest Price
for an Advanced
Microprocessor-Based
Mold Temperature
Control!
1061 Industrial Parkway, Medina, Ohio 44256, U.S.A.
Phone: 330-722-1182 • Toll Free: 800-345-7693
Fax: 330-725-2723 • Toll Free Fax: 800-581-9264
E-mail: [email protected]
310
ORDER TOLL FREE
1-800-345-7693
ISO 9001
Certified
Company
RMA Series Control Modules
Series RMA Technical Specifications
Performance Specifications
Auto Control Mode
Control Accuracy
Temperature Range
Temperature Stability
Calibration Accuracy
Power Response Time
Process Sampling
o o
F/ C
CompuStep® System
Control Mode
CompuStep® System
Duration
CompuStep® System
Output Voltage
CompuStep® System
Override Temperature
Operational Mode
Priority
CompuCycle® system.
±0.1oF (±0.1oC) dependent on the
total thermal system.
100 to 650oF (37 to 343oC).
±0.5% of full scale over the ambient
range of 32 to 131oF (0 to 55oC).
Better than 0.2% of full scale.
Better than 300 milliseconds.
100 milliseconds (nominal).
Jumper-selectable.
External T/C
Resistance
T/C Isolation
Cold Junction
Compensation
Input Type
Input Inpedance
Input Protection
Input Amplifier
Stability
Input Dynamic
Range
Common Mode
Rejection Ratio
Power Supply
Rejection Ratio
Voltages
Power Capability
Overload Protection
Power Line
Isolation
Output Drive
Variable stepping voltage, phase
fired.
240 Vac nominal, single phase 120
Vac available.
15 amperes, 3600 watts @240 Vac.
Triac and load use high speed
fuses. Both sides are fused.
Optically and transformer isolated
from ac lines. Isolation voltage is
greater than 2500 volts.
Internal solid state triac, triggered by
ac zero crossing pulses.
Controls And Indicators
Approximately 5 minutes.
Setpoint Control
Steps approximately from 25 VRMS
with 240 Vac line output, phase
fired.
% Power Conreol
Mode Control
Display
200oF (93oC).
Status Indicators
a. TC open, TC reverse, Shutdown,
and Open heater override
CompuStep® system.
b. Manual mode overrides TC open
TC reverse.
Power On-Off
Type “J”, grounded or
ungrounded
Two button up or down.
Resolution: 1oF (1oC).
Two buttons up or down.
Push button switch with LED
indicator for manual mode.
Top: 3-digit filtered LED
Bottom: 3-digit filtered LED.
Heat output alarm, F/C, % output,
Compustep, Maual, Closed Loop
Rocker switch, UL,CSA, and VDE
approved.
Electrical Power Specifications
Input Voltage
Frequency
DC Power Supplies
Input Specifications
Thermocouple (T/C)
Sensor
Output Specifications
Module Power
Usage
240/120 Vac, +10% -20%.
50 Hz ±3 Hz, 60 Hz ±3 Hz.
Internal generated, regulated and
temperature compensated.
Less than 3 watts, excluding load.
Maximum 100 ohms for rated
accuracy.
Isolated from ground and supply
voltages.
Automatic, better than 0.02oF/oF
(0.01 oC/oC).
Potentiometric.
10 megohm.
Diode clamp, RC filter.
Better than 0.05oF/oF (0.03oC/oC).
Greater than 999oF (537oC).
Greater than 100 dB.
Greater than 70 dB.
1061 Industrial Parkway, Medina, Ohio 44256, U.S.A.
Phone: 330-722-1182 • Toll Free: 800-345-7693
Fax: 330-725-2723 • Toll Free Fax: 800-581-9264
E-mail: [email protected]
ORDER TOLL FREE
1-800-345-7693
311
ISO 9001
Certified
Company
RMB Series Control Modules
Series RMB Temperature Control Module
The Athena Series RMB is a
microprocessor-based,
single-zone temperature controller
specifically designed for
runnerless molding applications.
It features an easy-to-use
operator keypad, two LED
displays, and three discrete
indicators for heat-current,
alarm and manual mode.
• Compatible with existing Athena
“G+”, D-M-E “G” Series, D-M-E
“Smart” Series, and other
standard mainframes.
• Accepts Type J or Type K
thermocouple input (jumper
selectable).
• Auto-tuning, with adjustable
proportional band and rate.
• Bumpless auto/manual transfer.
• Compu-Step® bakeout feature
prevents moisture at startup.
• Built-in loop break, short, open,
and reverse thermocouple
protection.
• Built-in triac safety protection.
• Ground-fault protection.
• Preset alarms at 30oF (17oC).
• Jumper-selectable soft-start mode.
• Current monitor feature displays
average current to load.
• SafeChange™ “hot swap” feature
allows safe removal and
replacement of module.
• CE-compliant.
312
15 Amp
Model RMBD15
1-11........... $190.00
12+............ $185.00
Model RMBD30
30 Amp ....................... $540.00
1061 Industrial Parkway, Medina, Ohio 44256, U.S.A.
Phone: 330-722-1182 • Toll Free: 800-345-7693
Fax: 330-725-2723 • Toll Free Fax: 800-581-9264
E-mail: [email protected]
ORDER TOLL FREE
1-800-345-7693
ISO 9001
Certified
Company
RMB Series Control Modules
Series RMB Technical Specifications
Performance Specifications
Auto Control Mode
Control Accuracy
Temperature Range
Temperature Stability
Calibration Accuracy
Power Response Time
Process Sampling
o o
F/ C
CompuStep® System
Control Mode
CompuStep® System
Duration
CompuStep® System
Output Voltage
CompuStep® System
Override Temperature
Operational Mode
Priority
CompuCycle® system.
±0.1oF (±0.1oC) dependent on the
total thermal system.
32 to 999oF (0 to 537oC).
±0.5% of full scale over the ambient
range of 32 to 131oF (0 to 55oC).
Better than 0.2% of full scale.
Better than 300 milliseconds.
100 milliseconds (nominal).
Jumper-selectable.
External T/C
Resistance
T/C Isolation
Cold Junction
Compensation
Input Type
Input Inpedance
Input Protection
Input Amplifier
Stability
Input Dynamic
Range
Common Mode
Rejection Ratio
Power Supply
Rejection Ratio
Voltages
Power Capability
Overload Protection
Power Line
Isolation
Output Drive
Variable stepping voltage, phase
fired.
240 Vac nominal, single phase 120
Vac available.
15 amperes, 3600 watts @240 Vac;
30 amperes, 7200 watts @240 Vac.
Triac and load use high speed fuses
Both sides are fused.
Optically and transformer isolated
from ac lines. Isolation voltage is
greater than 2500 volts.
Internal solid state triac, triggered by
ac zero crossing pulses.
Controls And Indicators
Approximately 5 minutes.
Setpoint Control
Steps approximately from 25 VRMS
with 240 Vac line output, phase
fired.
% Power Conreol
Mode Control
Display
200oF (93oC).
a. TC open, TC reverse, Shutdown,
and Open heater override
CompuStep® system.
b. Manual mode overrides TC open
TC reverse.
Input Specifications
Thermocouple (T/C)
Sensor
Output Specifications
Type “J” or Type “K”, grounded or
ungrounded (switch-selectable).
Status Indicators
Power On-Off
Two button up or down.
Resolution: 1oF (1oC).
Two buttons up or down.
Push button switch with LED
indicator for manual mode.
Top: 3-digit filtered LED
Bottom: 4-digit filtered LED.
Heat-current output alarm.
Rocker switch, UL,CSA, and VDE
approved.
Electrical Power Specifications
Input Voltage
Frequency
DC Power Supplies
Module Power
Usage
240/120 Vac, +10% -20%.
50 Hz ±3 Hz, 60 Hz ±3 Hz.
Internal generated, regulated and
temperature compensated.
Less than 3 watts, excluding load.
Maximum 100 ohms for rated
accuracy.
Isolated from ground and supply
voltages.
Automatic, better than 0.02oF/oF
(0.01 oC/oC).
Potentiometric.
10 megohm.
Diode clamp, RC filter.
Better than 0.05oF/oF (0.03oC/oC).
Greater than 999oF (537oC).
Greater than 100 dB.
Greater than 70 dB.
1061 Industrial Parkway, Medina, Ohio 44256, U.S.A.
Phone: 330-722-1182 • Toll Free: 800-345-7693
Fax: 330-725-2723 • Toll Free Fax: 800-581-9264
E-mail: [email protected]
ORDER TOLL FREE
1-800-345-7693
313
ISO 9001
Certified
Company
RMC Series Control Modules
Series RMC Temperature Control Module
The Athena Series RMC brings new
and highly productive benefits to
injection molders looking for a modular
hot runner controller that’s flexible, easy
to set up, and simple to operate. Using
the popular Modbus® communications
protocol, the next generation RMC
gives users the ability to set or change
all zones, either remotely from a
desktop computer, from a Palm®
handheld device, or (with the All
command) from any other individual
RMC module in the communication
equipped mainframe.
• Choice of three default modes for
open thermocouple condition.
• Built-in triac safety protection.
• Accepts J or K thermocouple
input (jumper selectable).
• SafeChange™ “hot swap” feature
allows safe removal and replacement
of module.
• Compu-Step® bakeout feature
prevents moisture in heaters at
startup.
• Built-in loop break, short, open, and
reverse thermocouple protection.
• “Boost” mode for temporary % of
power output increase.
• Ground-fault protection.
• Adjustable setpoint limits.
• Stores highest temperature
detected.
• Current monitor feature displays
average current to load.
• CE-compliant.
314
15 Amp
Model RMCD15
1-11........... $295.00
12+............ $280.00
1061 Industrial Parkway, Medina, Ohio 44256, U.S.A.
Phone: 330-722-1182 • Toll Free: 800-345-7693
Fax: 330-725-2723 • Toll Free Fax: 800-581-9264
E-mail: [email protected]
ORDER TOLL FREE
1-800-345-7693
ISO 9001
Certified
Company
RMC Series Control Modules
Series RMC Technical Specifications
Performance Specifications
Auto Control Mode
Control Accuracy
Temperature
Range
Temperature
Stability
Calibration
Accuracy
Power Response
Time
Process Sampling
o o
F/ C
CompuStep® System
Control Mode
CompuStep® System
Duration
CompuStep® System
Output Voltage
CompuStep® System
Override Temperature
Operational
Mode Priority
CompuCycle® system.
±0.1oF (±0.1oC) dependent on
total thermal system.
Voltages
Power Capability
±0.5% of full scale over the ambient
range of 32 to 131oF (0 to 55oC ).
Better than 0.2% of full scale.
External T/C
Resistance
T/C Isolation
Cold Junction
Compensation
Input Type
Input Inpedance
Input Protection
Input Amplifier
Stability
Input Dynamic
Range
Common Mode
Rejection Ratio
Greater than 70 dB.
Output Specifications
32 to 999oF (0 to 537oC).
Overload Protection
Power Line
Isolation
240 Vac nominal, single phase
120 Vac available.
15 amperes, 3600 watts
@240 Vac.
Triac and load use high speed
fuses. Both sides are fused (GBB).
Optically and transformer isolated
from ac lines. Isolation voltage is
greater than 2500 volts.
Internal solid state triac, triggered
by ac zero crossing pulses.
Better than 300 milliseconds.
100 milliseconds (nominal).
Jumper-selectable.
Output Drive
Variable stepping voltage,
phase fired.
Controls And Indicators
Setpoint Control
Approximately 5 minutes.
Steps approximately from 25 VRMS
with 240 Vac line output, phasefired.
200oF (93oC).
a. TC open, TC reverse, Shutdown
and Open heater override
CompuStep system.
b. Manual mode overrides TC open,
TC reverse.
Input Specifications
Thermocouple
(T/C) Sensor
Power Supply
Rejection Ratio
Type “J” or Type “K”, grounded or
ungrounded (switch-selectable).
% Power Control
Mode Control
Display
Status Indicators
Power On-Off
Two button up or down.
Resolution: 1oF (1oC).
Two buttons up or down.
Push button switch with LED
indicator for manual mode.
Top: 3-digit filtered LED.
Bottom: 4-digit filtered LED.
Heat-current output alarm.
Rocker switch, UL, CSA, and
VDE approved.
Electrical Power Specifications
Input Voltage
Frequency
DC Power
Supplies
Module Power
Usage
115 to 230 Vac, ± 10%.
50-60 Hz.
Internally generated, regulated
and temperature compensated.
Less than 6 watts, excluding load.
Maximum 100 ohms for rated
accuracy.
Isolated from ground and supply
voltages.
Automatic, better than 0.02oF/oF
(0.01 oC/oC).
Potentiometric.
10 megohms.
Diode clamp, RC filter.
Better than 0.05oF/oF (0.03oC/oC).
Greater than 999oF (537oC).
Greater than 100 dB.
1061 Industrial Parkway, Medina, Ohio 44256, U.S.A.
Phone: 330-722-1182 • Toll Free: 800-345-7693
Fax: 330-725-2723 • Toll Free Fax: 800-581-9264
E-mail: [email protected]
ORDER TOLL FREE
1-800-345-7693
315
ISO 9001
Certified
Company
RMT Series Control Modules
Series RMT (2 Zones per Slot) Temperature Control Module
The Athena Series RMT is a
microprocessor-based,
dual-zone temperature controller
specifically designed for
runnerless molding applications, effectively doubling the zone count per module
without doubling the price.
It features two easy-to-use
operator keypads, and discrete
indicators for heat output,
alarm, F/C indication, manual
and closed loop mode.
• Accepts Type J thermocouple.
• Bumpless auto/manual transfer.
• Compustep® bake out feature prevents
moisture at startup.
• Built-in loop break for open heater,
shorted triac, reverse or shorted
thermocouple.
• Preset alarms at 30oF (17oC).
• SafeChange™ “hot swap” feature
allows safe removal and
replacement of module.
• CE-compliant.
• 15 Amps per zone.
15 Amp
Model RMTD15
1-11........... $275.00
12+............ $260.00
An advanced mold temperature
control system that uses less space,
is easy to operate and costs much
less per hot runner zone than single
zone per module systems!
324
1061 Industrial Parkway, Medina, Ohio 44256, U.S.A.
Phone: 330-722-1182 • Toll Free: 800-345-7693
Fax: 330-725-2723 • Toll Free Fax: 800-581-9264
E-mail: [email protected]
ORDER TOLL FREE
1-800-345-7693
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement