Ammonia

Ammonia
Operating Instructions
Ammonia Cassette
(Part Number: 084015)
Applications:
The Chameleon is the only hands-free, power-free, chemical detector for gases
and vapors in air, allowing First Responders, Firefighters, EMS, Police Officers
and Military to detect the presence of hazardous chemicals. No liquid sample
required. The Chameleon may even be immersed in salt water or fresh water
without affecting its performance. Developed under funding by the United States
Marine Corps, the Chameleon is ideal for users to screen unknown hazards in
their environment.
According to the New York State Hazardous Substances Emergency Events
Surveillance Project, 24% of the events associated with First Responder injuries
were due to exposure to ammonia. Ammonia’s primary uses are as an
agricultural fertilizer and refrigerant in cold storage facilities. Ammonia is also an
ingredient in the manufacture of gunpowder and sulfuric acid as well as illegal
methamphetamines.
Specifications:
The chemical sensor in the ammonia cassette shows an easy to see color
change. Half of the sensor window will change color as shown in the example
below:
Operating Instructions:
1.
2.
3.
4.
5.
6.
The expiration date marked on the packaging assumes storage between 35 oF
and 140 oF, with an average storage temperature not exceeding 77 oF. An
average storage temperature above 77 oF will result in shorter shelf life.
At time of use - remove cassette from its protective pouch.
Holding cassette with text facing up, slide cassette into Chameleon armband until
the cassette firmly snaps into the armband.
Periodically view the cassette to observe color change in half of the sensor
window.
Discard cassette after color change is observed or after 24 hours of use.
DO NOT use cassette beyond 24-hour service life.
WARRANTY EXCLUSIONS AND LIMITATION OF LIABILITY
IF THE USER DOES NOT ACCEPT THE FOLLOWING TERMS, THE USER
SHOULD NOT USE THE CHAMELEON CASSETTES AND ARMBAND.
Seller warrants that, for the lesser of one (1) year or the shelf-life provided on the
Seller’s product, its packaging or its literature, its products shall conform to the
description of such products as provided on the Seller’s product, its packaging or its
literature. THIS WARRANTY IS EXCLUSIVE, AND SELLER MAKES NO OTHER
WARRANTY, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. Seller’s
warranties made in connection with this sale shall not be effective if Seller has
determined, in its sole discretion, that Buyer has misused the products in any manner,
has failed to use the products in accordance with safe industry standards and
practices, or has failed to use the products in accordance with Seller’s written
operating instructions, or other instructions furnished by Seller to Buyer.
Seller’s sole and exclusive liability and Buyer’s exclusive remedy with respect to
products to Seller’s satisfaction to be defective or nonconforming shall be replacement
of such products without charge or refund of the purchase price, in Seller’s sole
discretion, upon the return of such products in accordance with Seller’s instructions.
All claims must be brought within one (1) year of shipment, regardless of their nature.
Unexposed
Description
Ammonia
Concentration
150 ppm
Exposed
Reaction Time
1 - 3 minutes
Interferences:
The ammonia cassette was exposed to saturated vapor concentrations of
toluene, bleach, DEET, gasoline, diesel fuel and JP-8 jet fuel for one hour. No
false positive or false negative readings were observed. Repeated immersion in
a layer of oil/fuel on top of salt water had no effect on the performance of the
ammonia cassette. High concentrations of HCl (25 ppm) for > 3 minutes cause a
false positive indication on the ammonia cassette. Basic gases including, but not
limited to, hydrazine, 1,1-dimethylhydrazine, methylamine and allylamine will
cause a false positive interference.
Publication Number: 08-4015A.1-1107
SELLER SHALL NOT IN ANY EVENT BE LIABLE FOR INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES OF ANY KIND RESULTING FROM
ANY USE OR FAILURE OF THE PRODUCTS, EVEN IF SELLER HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGE INCLUDING, WITHOUT
LIMITATION, LIABILITY FOR LOSS OF USE, LOSS OF WORK IN PROGRESS,
DOWN TIME, LOSS OF REVENUE OR PROFITS, FAILURE TO REALIZE SAVINGS,
LOSS OF PRODUCTS OF BUYER OR OTHER USE OF ANY LIABILITY OF BUYER
TO A THIRD PARTY ON ACCOUNT OF SUCH LOSS, OR FOR ANY LABOR OR
ANY OTHER EXPENSE, DAMAGE OR LOSS OCCASIONED BY SUCH PRODUCT
INCLUDING PERSONAL INJURY OR PROPERTY DAMAGE UNLESS SUCH
PERSONAL INJURY OR PROPERTY DAMAGE IS CAUSED BY SELLER’S GROSS
NEGLIGENCE.
Warning: Keep out of reach of children, if ingested seek medical attention
immediately.
US Patent No. 6,284,198 and other patents pending
Morphix Technologies, 2557 Production Rd., Virginia Beach, VA 23454
Phone: +1-757-431-2260 Fax: +1-757-216-6209
www.morphtec.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF