QSC_DDI-9-DDI-10_InstallGuide_EN_RevA

QSC_DDI-9-DDI-10_InstallGuide_EN_RevA
DDI-9 and DDI-10
DataPort Accessory Card
I N S TA L L AT I O N G U I D E
QSC Audio Products, Inc.,
1675 MacArthur Boulevard
Costa Mesa, California 92626 USA
▼
DDI-9
▼
DDI-10
*TD-000169-00*
*TD-000169-00*
Rev. A
PH: (714) 754-6175 FAX: (714) 754-6174
QSControl is a trademark of QSC Audio Products, Inc. “QSC” and the QSC logo are registered with the U.S. Patent and Trademark Office.
4
1
III. WARRANTY AND DISCLAIMERS
Instructions for the DDI-9 and DDI-10 DataPort Accessory Cards
QSC Audio Products, Inc. is not liable for any damage to speakers, amplifiers, or any other equipment that is caused by negligence or improper
installation and/or use of the DDI-9 or DDI-10 DataPort Accessory Card.
I. INTRODUCTION
The DDI-9 and DDI-10 DataPort Accessory Cards are designed for use with QSC’s four-channel CX and
DCA amplifiers. Both provide a relay-switched contact closure and opening if the amplifier fails, shuts
down, or is turned off, as well as means to remotely switch the amplifier on or into standby with a
remote pair of switch contacts. For inputs, both also provide both DataPort and Phoenix Connector
“Eurostyle” pluggable connectors.
The DDI-9 also allows muting of the amplifier’s four inputs, either individually or in groups, using remote
switch contact closures (Figure 1).
PRODUCT WARRANTY
Opens on fault
Common
Closes on fault
Close to mute:
Mute Channel 4
Mute Channel 3
Mute Channel 2
Mute Channel 1
QSC Audio Products, Inc. ("QSC") guarantees its products to be free from defective material and / or workmanship for a period of three (3) years from
date of sale, and will replace defective parts and repair malfunctioning products under this warranty when the defect occurs under normal installation
and use - provided the unit is returned to our factory or one of our authorized service stations via pre-paid transportation with a copy of proof of purchase
(i.e., sales receipt). This warranty provides that the examination of the return product must indicate, in our judgment, a manufacturing defect. This
warranty does not extend to any product which has been subjected to misuse, neglect, accident, improper installation, or where the date code has been
removed or defaced. QSC shall not be liable for incidental and/or consequential damages. This warranty gives you specific legal rights. This limited
warranty is freely transferable during the term of the warranty period.
Amp standby
The DDI-9 or DDI-10 card mounts onto the two DataPort connectors on the back of the amplifier and
secures to the amplifier with four screws. The card is powered by the amplifier through the DataPort. Figure 1. The DDI-9 and its control/monitoring
To guard against oxidation, corrosion, or contamination, the circuit board is treated with non-toxic connections. The DDI-10 has the same standby
and fault features, but no channel muting.
protectants. Therefore, it may have a slight odor and a slightly oily-feeling residue. Do not wash the
protectant off the circuit board.
The customer may have additional rights, which vary from state to state.
In the event that this product was manufactured for export and sale outside of the United States or its territories, then this limited warranty shall not
apply. Removal of the serial number on this product, or purchase of this product from an unauthorized dealer, will void this limited warranty.
Contact us at 800-772-2834 (USA only) or +1 (714) 957-7150, or visit our Web site at www.qscaudio.com
TECHNICAL ASSISTANCE
CHANNEL MUTING
With a DDI-9, any of the four inputs can be muted by making an electrical connection between the appropriate channel mute
terminal and the ground terminal. This allows you to use switches mounted remotely from the amplifier to mute channels.
You can mute and unmute multiple channels simultaneously with one switch by tying their respective connections together
to the single pair of switch contacts (Figure 2).
If you suspect that your DDI-9 or DDI-10 card is defective, check your system configuration and onnections to determine the origin of the problem. In
many cases, incorrect audio interfacing, poor cabling, or other system level impairments are the causes of problems in audio systems. For technical
assistance beyond the information given in this manual, contact the QSC Technical Services department.
Close to mute:
Mute Channels 2–4
Mute Channel 1
FACTORY SERVICE
Figure 2. Two or more
channel mute connections
A switch closure between the ground and the standby terminals will put the amp’s power supply in standby. Opening the may be tied together to
closure will restart the power supply, with no inrush current surge.
the same switch contacts.
ON/OFF CONTROL
If your DDI-9 or DDI-10 card ever requires factory service, contact the QSC Technical Services department for return instructions and a Return
Authorization (RA) number. QSC is not responsible for products returned without a Return Authorization number.
PRODUCT RETURN GUIDELINES
1.
2.
3.
4.
5.
INPUTS
For inputs, the DDI-9 or DDI-10 offer both Phoenix Connector “Eurostyle” pluggable headers and DataPort
connections. The DataPort connections are fully compatible with QSControl, Basis, and DataPort accessories such
as the DSP-3 and DSP-4.
DDI-9
mounted
to main
amp
Pack the product securely for protection during shipment. QSC will provide factory packaging free of charge, on request.
Include a copy of the sales receipt, your name, return address, phone number, and a description of the problem.
Call QSC Technical Services department for a Return Authorization number.
Write the Return Authorization number on the outside of the shipping package.
Ship the product prepaid to QSC Audio Products. We recommend United Parcel Service (UPS).
AMPLIFIER FAULTS
There are three connections for the amplifier fault indication output: Fault NC (closes on fault), Common, and Fault
NO (opens on fault). When the amplifier is operating normally, the relay connects the NO terminal to the common
and the NC terminal is open.
NOTE: The standby amp
must be connected to AC
power and turned on.
To DataPort pin 2
of standby amp
To DataPort pin 6
of standby amp
Any time the amplifier shuts down, is turned off, goes into protect, or otherwise fails, the relay will close the NC
Figure 3. Using the DDI-9 or DDIterminal and open the NO. This can be used for many purposes, including turning on a backup amplifier if the main 10 to activate a backup amplifier.
one fails (Figure 3).
II. INSTALLATION
The DDI-9 kit (QSC part # SG-000513-00) includes these items:
DDI-9 board
Four #4-40 × ¼” black screws
Installation guide
The DDI-10 kit (QSC part # SG-000514-00) includes these items:
DDI-10 board
Four #4-40 × ¼” black screws
Installation guide
DDI9 and DDI-10 Specifications
QSC Technical Services
1665 MacArthur Blvd.
Costa Mesa, CA 92626 USA
Telephone:
(800) QSC AUDIO [(800) 772-2834] USA only
+1 (714) 957-7150
+1 (714) 754-6175
Fax:
+1 (714) 754-6173
Web:
www.qscaudio.com
QUALIFIED SERVICE CENTERS
Input sensitivity (CX models)
3.4 volts rms (+12.8 dBu)
Input sensitivity (DCA models)
3.2 volts rms (+12.3 dBu)
Relay contact rating
30 volts, 2 amperes
QSC maintains a service center network for your convenience. If you choose to return your product to a local service center and need a referral, contact
QSC Technical Services department. Accessories, input modules, and other peripheral QSC products must be returned to the factory for service.
INTERNATIONAL SERVICING
For QSC products purchased outside the United States, refer service to the distributor or dealer from which the product was purchased. There are
numerous service centers in many countries. Your dealer, distributor, or QSC Technical Services can refer you to a service center in your country.
Use this procedure to install the DDI-9 or DDI-10:
2
1.
Turn off the amplifier.
2.
Plug the card into the amplifier’s DataPorts. Use the four screws on each side of the DataPorts to secure it; do not overtighten them.
3.
To attach wires to the DDI-9 or DDI-10 terminal strip, strip about 5 mm (0.2”) of insulation from the wire. Twist the exposed wire strands
together and make sure there are no stray ones. Turn the screw on the terminal counterclockwise until you can fully insert the wire end into
the terminal. Turn the screw clockwise until the terminal clamps the wire securely. Repeat for all the wires needed.
4.
The amplifier is ready for use.
3