Installation Instructions
Design Highlights
-Quiet Smooth Action with Variable Speed Motion
-Full Cable Management
-Stylish Look and Finish
-Onboard Electronics
-Wide Range of Mounting Options
Thank you for choosing
futureautomation
email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
ISSUE 012
Wall Mounts
PSE90 Flat Screen Electric Wall Mount
Introduction: Safety Information
PSE90 Flat Screen Electric Wall Mount
Caution
Beware of
Danger
Keep Hands
Safety Disclaimer
Warning
Moving Parts
Clear
Important Safety Instructions
Electricity
Explanation of graphical symbols
-(Electric Shock Symbol) = The lightning flash within an equilateral triangle is intended to alert you to the presence of un-insulated
“dangerous voltage” within the products enclosure that may be of sufficient magnitude to constitute an electric shock to persons
-(Caution Symbol) = The exclamation point within an equilateral triangle is intended to alert you to the presence of important
operating and maintenance (servicing) instructions in the literature accompanying the product
-(Tools Symbols) = The tools symbol within a coloured square are intended to highlight the required tools necessary for correct and
safe installation of the product. These are intended as a
guide only, and it is at the installer’s discretion as to which tools are used.
WARNING: RISK OF ELECTRIC SHOCK, ONLY AUTHORIZED INSTALLERS TO OPEN THE POWER CONTROL BOX.
WARNING: To reduce the risk of fire or electric shock, do not expose electrical parts to rain or moisture, unless the
product has been specifically designed to do so.
WARNING: Failure to provide adequate structural strengthening, prior to installation can result in serious personal injury or damage to the
equipment. It is the installer’s responsibility to ensure the structure to which the component is affixed can support the four times the
weight of the component.
WARNING: Do not exceed the weight capacity. This can result in serious personal injury or damage to the equipment. It is the installer’s
responsibility to ensure that the total combined weight of all attached components does not exceed that of the maximum figure stated.
WARNING: Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the structure to which this component is attached can support five times the combined
weight of all equipment. Reinforce the structure as required before installing the component.
Warnings:
1.
Read all technical instructions fully before installation and use. It is the installer’s responsibility to ensure that all
documentation is passed on the end user and read fully before operation.
2.
Keep all documentation.
3.
Heed all warnings.
4.
Follow all technical specifications and instructions during installation.
5.
Do not use near water unless the product has been specifically designed to do so.
6.
Clean only with a dry cloth.
7.
Do not defeat the purpose of the polarized or grounding type plug. A polarized plug has two blades, one wider
than the other. A grounding type plug has two blades and a grounding prong. The wide blade or third prong are
provided for your safety. If the provided plug does not fit your outlet, consult an electrician or contact the
manufacturer.
8.
Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the
point where the exit from the apparatus.
9.
Unplug the apparatus during lightning storms or when unused for long periods of time.
10.
Only use attachments/accessories specified by the manufacturer.
11.
Refer all servicing to qualified personnel. Servicing is required regularly on an annual basis, when the apparatus is
damaged in any way, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been
exposed to rain or moisture, does not operate normally, or has been dropped.
12.
To completely disconnect the apparatus form the AC mains, disconnect the power cord plug from the AC
receptacle on the power control box.
13.
To prevent overheating, do not cover the apparatus. Install in accordance with the instructions.
14.
UK, Ireland and Hong Kong only – The power cord is supplied with a 13A plug having an earthing pin. The
apparatus is earthed and this pin is not required for safety, merely to operate the safety shutter of mains outlet.
15.
No naked flames such as lit candles should be placed on the unit.
16.
Observe and follow the local regulations when disposing of batteries.
17.
Do not expose the unit to dripping or splashing fluids.
18.
Do not place objects filled with liquid, such as vases, on the unit.
19.
Do not expose the batteries to excessive heat such as sunshine, fire or the like.
20.
For all mounted apparatus, the apparatus should be installed on solid wood, bricks, concrete or solid wood
columns and battens.
21.
Always turn off power at source before putting on or taking off parts and cleaning.
22.
Do not use outdoors unless marked for outdoor use.
23.
Exceeding the weight capacity can result in serious personal injury or damage to equipment.
Future Sound & Vision trading as Future Automation intend to make this and all documentation as accurate as possible. However, Future
Automation makes no claim that the information contained herein covers all details, conditions or variations, nor does it provide for every
possible contingency in connection with the installation or use of this product. The information contained in this document is subject to
change without prior notice or obligation of any kind. Future Automation makes no representation of warranty, expressed or implied,
regarding the information contained herein. Future Automation assumes no responsibility for accuracy, completeness or sufficiency of the
information contained in this document.
Page 1 of 17 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
PSE90 Flat Screen Electric Wall Mount
Page
Introduction
Safety Information
Contents
Contents
Tool Indicator Icons
1
2
3
3
Parts List
Package Contents
Stage 1
Screen Fitment
Before You Start Check
Stage 2
Vertical Height Alignment
Stage 3
Opening The Mechanism Prior To Fitting
4
4
Installation
Stage 4
Fitting The Mechanism To The Wall
Stage 5
Removing The Side Panel & Cable Management
Stage 6
Mounting The Screen
Stage 7
Final Checks & Set Up
Electrical Connections
Contact Closure
RS232
Operation Details
5
5
6
7
8
9
10
11
12
13
13
Operations
IR Control
IR Operation Buttons
Changing Batteries
Storing Positions
14
14
14
14
Trouble Shooting
15
Technical Overview
16
Page 2 of 17 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
Introduction: Contents
Contents
Introduction: Contents / Tool Indicator
PSE90 Flat Screen Electric Wall Mount
Tool Indicator Icons
1.
2.
1. - Drill
2. - Tape measure
3.
4.
3. - Allen Keys
4. - Spirit Level
5.
6.
7.
5. - Screwdrivers
6. - Spanners
8.
7. - Pencil
8. - Saw
Product Warranty
This product carries a warranty that covers the cost of labour and spare parts incurred by any defects in materials and workmanship under normal use
during a two year period from date of purchase. Support for any problems that are not hardware faults are excluded from the warranty entitlement.
This warranty does not affect your statutory consumer rights.
The following is excluded from warranty service:
•
Malfunctioning caused by misuse or damage, accidental or otherwise, or service modification by persons not authorised by Future Automation,
or the use of any non Future Automation supplied parts;
•
Any electrical, or other environmental work external to your Future Automation mechanism including power cuts, surges or lightning strikes;
•
Additional items not supplied by Future Automation although they may have been supplied together by the retailer;
•
Any 3rd party software products controlling your mechanism;
•
Any transfer of ownership. Warranty is provided only to the initial purchaser;
•
Compensation for loss of use of the product, and consequential loss of any kind;
•
Use of the product over the specified weight capacity;
•
Any damage to products during transit that is not checked and notified as “unchecked” or “damaged” upon receipt of delivery.
Any part of your system that needs to be replaced during a warranty repair becomes the property of Future Automation.
Page 3 of 17 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
PSE90 Flat Screen Electric Wall Mount
1 - Mechanism
1.1 - Screen Mount Plate
1.2 - Wall Mount Plate
1.3 - Mechanism Cover
1.4 - Link Arm
2 - IR Remote Control
Not Shown On Page
3 - x2 AAA Batteries
4 - Multi Pack Of Nut, Bolts & Washers
5 - Mains Power & Other Leads
Nuts & Bolts Multipack:
A range of nuts, bolts, washers
and spacers to help add in the
mounting for your screen
Installation: Package Contents
Package Contents
(Your pack may also contain a custom adapter
if your screen is not VESA compatible)
1.4
1
1.2
1.3
2
1.1
Page 4 of 17 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
Installation: Stage 1
PSE90 Flat Screen Electric Wall Mount
Screen fitment
Before you start, check the following:
-The product is in good condition
-No damage to any parts
-Wiring is all secure
-The unit is in the closed position
-When testing the product make sure to run in
the operating position
Screen symmetrical
about this centre line
If your screen is not a VESA compatible, then a custom adapter will need to be added to the PSE90
bracket to suit your screen. Further instructions relating to any custom mount will be included with
the custom adapter.
When fitting the screen to the mechanism, make sure that the centre of any adaptor plate is in line
with the centre hole on the mechanism.
Page 5 of 17 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
PSE90 Flat Screen Electric Wall Mount
Carefully place the screen face down on
the floor and then fix the PSE90 to the
screen using the fixings supplied
Measure the distance from the top of the
screen down to the top mounting hole on
the wall plate. From this measurement it
is possible to determine where to drill the
holes in the wall
Remove screen from the mount before attaching the mechanism to the wall
Page 6 of 17 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
Installation: Stage 2
Vertical height alignment
Installation: Stage 3
PSE90 Flat Screen Electric Wall Mount
Opening the mechanism prior to fitting
Before fitting the mechanism to the wall, it will need to
be opened to allow access to the wall plate. This must
be done as per these instrutions to avoid damage to
the mechanism.
1 - Hold the PSE90 by the wall plate,
upside down (link arm underneath as
shown) on a soft, non-abrasive
surface that is free from any
obstructions.
2 - Make sure the power is
connected and press the "Home"
button on the remote control. This
will open the bracket to 45 degrees.
3 - Remove the power and turn the
PSE90 the correct way up, before
fitting onto the wall as shown on
the next page.
Page 7 of 17 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
Installation: Stage 4
PSE90 Flat Screen Electric Wall Mount
Fitting the mechanism to the wall
Once you have decided on the location of your
screen you can fix the wall plate to the wall.
Step 1
1 - Fix the top 2 screws into the wall.
Keyhole details are 200mm apart,
symmetrical about screen centre
2 - Hang the mechanism on the
screws using the key hole detail at
the top of the wall mounting plate
3 - Continue to secure the
other 6 fixings in place
Step 2
Fixings
-Fix through one of the top holes first
-Using the wall plate as a template, mark
the other holes before drilling into the wall
-Make sure a spirit level is used at all times
to ensure mechanism is always level
Wall Plate
Plaster Board
It is the installers responsibility to choose
the appropriate fixings when attaching to
the wall and to make sure the mechanism
is safe and secure.
Make sure the wall which the PSE90 is
being mounted to is structurally suitable
Maximum head
height of fixings
allowable 5.50mm
Page 8 of 17 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
Supporting
Structure
PSE90 Flat Screen Electric Wall Mount
Before fitting the screen run the cables
through the mechanism. Take off the side
panel as shown by removing the 4 bolts,
2 top and 2 bottom, that hold it in place.
Disconnect the
mains power before
removing the panels.
Installation: Stage 5
Removing side panel & cable management
Cable management
Now you can feed the cables through the inner tube, along
the lower strut and back down the outer tube. Keep all the
cables well secured. Use as low profile cables as possible
Replace side
panels before
using the PSE90
Page 9 of 17 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
Installation: Stage 6
PSE90 Flat Screen Electric Wall Mount
Mounting the screen
Attach the screen to the mounting
plate using the appropriate fixings
found in the fixtures pack.
It may be necessary with some
screens to use spacers to provide
clearance for AV cables at the rear
Make sure the mechanism is
out when mounting the screen
Mechanism with
screen attached
Page 10 of 17// email [email protected] tel:+ 44( 0) 1438 833577 fax:+ 44( 0) 1438 833565
PSE90 Flat Screen Electric Wall Mount
Installation: Stage 7
Final Checks & Set Up
-Make sure that both side panels are fitted
securely in place
-Nothing is obstructing the movement of
the mechanism or screen
-Product is square and level on the wall
-The product condition is good and all the
wiring is neatly organised
Bracket movement
and preset options:
IN
A
B
C
HOME
&
PRESET
D
E
F
OUT
The PSE90 has standard preset positions,
linked to the buttons shown above.
The preset options are not active until the mechanism has gone fully OUT and IN.
If the mechanism is moving and the power is cut, to revise ALL positions the mechanism needs to
go back to the IN position, after which the previously stored programmed positions will be retained.
Storing new locations - Press STOP in the desired position then press STORE and you’ll have a
2 second window to press HOME, PRESET or buttons A-F to save that position to that particular
button. Multiple custom positions can be stored.
Page 11 of 17 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
Installation: Electrical connection
PSE90 Flat Screen Electric Wall Mount
SLQV
Contact Closure
Use an RJ45 connector in the
CCI socket on the control box
to operate via contact closure
WIRE / CABLE
568A
568B
PIN
DESCRIPTION
ACTION
1
12V SUPPLY
12V SUPPLY - CURRENT LIMITED
W/G
W/O
2
12V LATCH
When 12V attached, device will go OUT to PRESET
position. When 12V removed, device will go IN.
G
O
3
GROUND
GROUND
W/O
W/G
4
DEVICE LATCH
Short to GROUND (pin 3), device will go OUT to PRESET
position, remove short device will go IN.
BL
BL
PIN 4 NOT USED
W/BL
W/BL
5
6
DEVICE STOP
Momentary short to GROUND (pin 3), stops device in
current position.
O
G
7
DEVICE OUT
Momentary short to GROUND (pin 3), makes device go
OUT.
W/BR
W/BR
8
DEVICE IN
Momentary short to GROUND (pin 3), makes device go
IN.
BR
BR
LED 1
LED 2
LED 3
LED 4
LED 5
CONTACT CLOSURE INPUT
NOTE:
Earlier versions of the control board
may not have these contact closure
LED indicators.
Page 12 of 17 // email [email protected] tel: + 44 ( 0) 1438 833577 fax: + 44 ( 0) 1438 833565
PSE90 Flat Screen Electric Wall Mount
Installation: RS232
Details
Baud rate:
Stop bit:
Parity:
Databits:
9600
1
None
8
Pin 1: RX
Pin 6 : TX
Pin 3 & 4: GROUND
SLQV
RS232
- Use an RJ25 connector in the socket marked
RS232 on the control box to operate using RS232
IMPORTANT
Ensure protocol is entered exactly as written, including
Carriage Return
(Enter / ASCII 13). After pressing
STORE you have a 2 second window to select your
save button, after 2 seconds the command is void.
Pin 2: TX
Pin 3: RX
Pin 5: GROUND
RJ25
Operation Details
IR LED
TO
PIN 2: TX
PIN 6: TX
TO
PIN 3: RX
PIN 4: GROUND TO PIN 5: GROUND
ACTION
Step 2
fa_(preset, home,A-F)
PIN 1: RX
PIN 3: GROUND TO PIN 5: GROUND
COMMAND
Step 1
fa_in
fa_out
fa_stop
fa_store
fa_preset
9 PIN D
Device IN
Device OUT
Device STOP
Store memory position
Device to stored memory position
IR Input
Jack
Contact Closure
RS232
DC1
Low voltage power output for
motor drive.LED’s to show
operation of limit switches
and positional counters
Mains Voltage Input
Page 13 of 17 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
Installation: Operations
PSE90 Flat Screen Electric Wall Mount
Note
Only buttons indicated are
functional with the product
Operation buttons for the IR remote
Out - Brings the
bracket fully out
90 to the wall
In - Brings the bracket
fully in parallel to the wall
Stop - Will stop
the operation at
any position
Preset - Brings the bracket
back out to the stored position
Store and then Preset Stores the current location
into the PSE90 memory
Store and then
A,B,C,D,E,F - can
also be stored as
preset positions
Replacing batteries
Future Automation
IR Remote
Controller needs x2
AAA batteries which
are provided within
the packaging
Storing favourite position
Store your favourite viewing position,
which can be learned over and over again
2 Press STOP to stop at desired position
3 Then press STORE and then PRESET
to learn that position
1 Press
IN before
starting
5 Press PRESET to make
the bracket come out to the
stored position
Page 14 of 17 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
4 Then return
to the IN position
PSE90 Flat Screen Electric Wall Mount
For information & technical support on our products
please refer to the relevant web site or phone number General Contact
[email protected]
+44 (0)1438 833577
US Contact
[email protected]
+1 (603) 742 9181
Page 15 of 17 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
Trouble Shooting:
Wall Mount M-PSE90 - Trouble shooting
Technical overview:
PSE90 Flat Screen Electric Wall Mount
A general technical overview of the PSE90 flat screen electric wall mount
Product Dimensions
(W,D,H When Closed)
Weight (Kg)
PSE90
580x95x455mm
[22.8x3.7x17.9"]
18Kg [39.7lb]
Power Consumption
Max 120W
Power Consumption
On Standby
3W
Lifting Capacity (Kg)
100Kg [220.5lb]
Standard Colour
Max Rotation
Black
90ȗ
Max Television Size
(Width)
1400mm [55.1"]
IR Remote, RF Remote,
Contact Closure & RS232
Control
Power Supply
240V or 110V
Control Of 3rd
Party Product
No
Output Power Supply
No
Shipping Details
Dimensions (W,D,H)
Weight (Kg)
700x600x200mm
[27.6x23.6x7.9"]
25Kg [55.1lb]
Page 16 of 17// email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
PSE90 Flat Screen Electric Wall Mount
Notes...
Page 17 of 17 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565
Future Automation
Unit 2 Kimpton Enterprise Park
Claggy Road
Kimpton
Hertfordshire
SG4 8HP
United Kingdom
Tel: +44 (0) 1438 833 577
Fax: +44 (0) 1438 833 565
Email: [email protected]
www.futureautomation.co.uk

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement