PathBuilder® S700
¨
WAN Access Switch Reference Guide
Release 2.03
http://www.3com.com/
Part No.3C64917
010-12197-0001
Published November 1998
3Com Corporation
5400 Bayfront Plaza
Santa Clara, California
95052-8145
© 3Com Corporation, 1998. All rights reserved. No part of this documentation may be reproduced in any
form or by any means or used to make any derivative work (such as translation, transformation, or
adaptation) without permission from 3Com Corporation.
3Com Corporation reserves the right to revise this documentation and to make changes in content from
time to time without obligation on the part of 3Com Corporation to provide notification of such revision or
change.
3Com Corporation provides this documentation without warranty of any kind, either implied or expressed,
including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose.
3Com may make improvements or changes in the product(s) and/or the program(s) described in this
documentation at any time.
UNITED STATES GOVERNMENT LEGENDS:
If you are a United States government agency, then this documentation and the software described herein
are provided to you subject to the following restricted rights:
For units of the Department of Defense:
Restricted Rights Legend: Use, duplication, or disclosure by the Government is subject to restrictions as set
forth in subparagraph (c) (1) (ii) for Restricted Rights in Technical Data and Computer Software Clause at 48
C.F.R. 52.227-7013. 3Com Corporation, 5400 Bayfront Plaza, Santa Clara, California 95052-8145.
For civilian agencies:
Restricted Rights Legend: Use, reproduction, or disclosure is subject to restrictions set forth in subparagraph
(a) through (d) of the Commercial Computer Software - Restricted Rights Clause at 48 C.F.R. 52.227-19 and
the limitations set forth in 3Com Corporation’s standard commercial agreement for the software.
Unpublished rights reserved under the copyright laws of the United States.
If there is any software on removable media described in this documentation, it is furnished under a license
agreement included with the product as a separate document, in the hard copy documentation, or on the
removable media in a directory file named LICENSE.TXT. If you are unable to locate a copy, please contact
3Com and a copy will be provided to you.
Unless otherwise indicated, 3Com registered trademarks are registered in the United States and may or may
not be registered in other countries.
3Com and PathBuilder are trademarks of 3Com Corporation.
Other brand and product names may be registered trademarks or trademarks of their respective holders.
CONTENTS
WARNING INFORMATION
Servicing ix
Rack Mounting ix
Power and Power Cords ix
EMI x
Safety Classification of Ports for Connection to Telecommunications Networks
SUPPLEMENTARY REGULATORY INFORMATION
Host Chassis/Module Compatibility and Creepage/Clearance Requirements
FCC Part 68 Statement xii
CE Notice xiii
ABOUT THIS GUIDE
Introduction 1
How to Use This Guide
Conventions 2
Related Documentation
1
1
3
SYSTEM DESCRIPTION
Introducing the PathBuilder S700 5
PathBuilder S700 Features 5
Key Features of the STX Module
PathBuilder S700 Architecture 6
Specifications 8
Options and Parts List 12
2
5
INSTALLATION
Receiving and Inspecting the PathBuilder S700 15
Installation Overview 15
Site Requirements 16
Step 1: Install the Shelf in the Rack 16
Step 2: Connect AC or DC Power 17
Step 3: (If needed) Install Additional Modules in the Shelf
Step 4: Connect I/O Cabling and Wiring 22
Normal Startup Sequence 23
Connecting a DS3 UNI or E3 UNI Module 23
21
xi
x
Connecting an OC3/STM-1 UNI Module 26
Connecting a DS1/E1 UNI with IMA Module 27
Connecting an Ethernet Module 28
Connecting a DSX-1 CBR or E1 CBR Module 30
Connecting a QSIM V.35/RS422/EIA530 Module 33
Connecting a HSIM Module 44
Connecting a DS1 Frame Access Module 46
Verifying CPU LEDs and Connecting the Office Alarm Connector 47
Connecting the Office Alarms 48
Verifying STX LEDs and Connecting the Optional BITS Clock 51
Connecting the Optional BITS Clock (STX) 51
Connecting Rear Redundant Modules 53
Step 5: Connect a Management Terminal 55
3
GETTING STARTED
Logging On 57
Using the Menus 59
Navigating through the Menus 59
Understanding the Menu Hierarchy 60
Using the Menus to Change Settings 60
Alarm Indicator 60
Performing Initial Configuration 61
Setting up Communication Parameters 62
Configuring the Local Host IP Address 63
Configuring Trap Clients 66
Configuring the Default Gateway 68
Configuring In-band Management 68
In-band Management via the 10Base-T Port on the Near-end MCPU Card
In-band Management via the Near-end Dual Ethernet Module 70
Performing Super User Functions 70
Setting Passwords 71
Taking over a Read-Write Session 72
Erasing the System Database 72
Setting the Time and Date 73
4
PATHBUILDER S700 MODULE AND APPLICATION OVERVIEW
ATM Overview 75
Virtual Circuits 75
System Module Overview 77
Management CPU Module 77
SNMP MIB Standards Support
STX Module 78
Priority Queuing 79
ATM Module Overview 79
DS3 UNI Module Overview 80
E3 UNI Module Overview 80
78
68
OC3/STM-1 UNI Module Overview 80
DS1/E1 UNI with IMA Module Overview 80
Application Module Overview 80
Ethernet Module Overview 81
Ethernet Module Standards Support 81
Ethernet Module Operation 81
DSX-1/E1 CBR Module Overview 82
DSX-1 CBR Module 82
E1 CBR Module 83
QSIM/HSIM/FAM Module Overview 84
Supported Applications 85
Bridging 85
Filtering 86
Addressing 86
Learning Bridge 86
Segmentation 87
Reassembly 88
Spanning Tree 88
Spanning Tree Operation 89
Spanning Tree Instances 89
CBR Application 90
Structured DS1 90
DS0 Signaling and Dynamic Bandwidth Allocation
Unstructured DS1 93
Structured versus Unstructured Summary 95
Ethernet and Voice Application 95
Frame Application 99
DXI Mode 1A 99
Frame Relay Interworking Functions 102
HDLC/SDLC 103
5
92
CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND
APPLICATIONS
Viewing and Configuring System Information 105
Specifying General System Information 106
Managing the System Clock 107
Alarm Conditions that Cause Clock Source Failure 110
Viewing and Configuring RS-232 Parameters 110
Viewing the Firmware Version 111
Downloading New Firmware 112
Downloading Firmware via the Ethernet Port 113
Downloading Firmware via the Serial Port 113
Downloading Firmware via FTP 114
Updating the Flash File System 114
Resetting the Interface Card 115
Viewing an Equipment List 115
Backing up and Restoring the Database and Code Image 116
Backing up the Database 116
Restoring the Database 117
Backing up the Code Image 117
Restoring the Code Image 118
PathBuilder S700 Configuration Overview 118
Configuring the PathBuilder S700 Shelf and the Application Modules 119
Setting Application Module Status 120
Configuring the Shelf 120
Setting Power Supply Status 121
Setting External Alarm Status 121
Configuring the Management CPU 122
Viewing MCPU Configuration Information 122
Configuring Virtual Interfaces 122
Adding Virtual Interfaces 123
Viewing and/or Modifying Existing Virtual Interfaces 125
Deleting Virtual Interfaces 126
Configuring Input Shapers 126
Configuring the STX Module 127
Configuring OC3/STM-1 UNI Modules 128
Configuring DS3 UNI Modules 130
Configuring E3 UNI Modules 133
Configuring DS1 UNI or E1 UNI with IMA Modules 134
Configuring DS1/E1 UNI Ports 135
Activation/Deactivation Bit Error Rates 137
Configuring UNI and IMA Groups 138
Adding UNI Groups 138
Adding IMA Groups 140
Viewing and Modifying IMA and UNI Groups 142
Configuring Virtual Interfaces for IMA Groups 143
Deleting IMA and UNI Groups 143
Viewing IMA Link Status 145
Viewing IMA Group Status 147
Configuring DS1 UNI or E1 UNI Cards 150
Configuring Ethernet Modules 151
Configuring Ethernet Ports, Cards, Shapers and Virtual Interfaces 151
Configuring the Bridge 153
Configuring Source Protocol Filtering 155
Configuring Source Address Filtering 156
Configuring Destination Address Filtering 158
Viewing the List Forwarding Table 159
Constructing the Bridge Static Table 160
Enabling and Disabling the Spanning Tree 161
Configuring IP Over ATM 161
Configuring DSX-1 CBR or E1 CBR Modules 166
Configuring QSIM/HSIM/FAM Modules 172
Configuring QSIM/HSIM/FAM Ports 172
QSIM/HSIM/FAM Performance at Small Frame Sizes 176
Configuring the QSIM/HSIM/FAM Local Management Interface 178
Configuring QSIM/HSIM/FAM Cards 180
Configuring Virtual Circuits 181
Summary of Supported VPI/VCI Ranges and Number of Connections
Adding Virtual Circuits 183
Configuring Unicast Virtual Circuits 185
Configuring Multicast Source Virtual Circuits 189
Configuring Multicast Leaf Virtual Circuits 190
Virtual Circuit Parameters 191
Common Virtual Circuit Parameters 192
ATM Module Virtual Circuit Parameters 193
Ethernet Module Virtual Circuit Parameters 193
CBR Module Virtual Circuit Parameters 193
QSIM/HSIM/FAM Virtual Circuit Parameters 195
Viewing Existing Virtual Circuits 199
Viewing Virtual Circuits for the Entire Chassis 199
Viewing Virtual Circuits by Port or Group 201
Modifying Virtual Circuits 203
Deleting Virtual Circuits 204
Viewing Virtual Circuit Statistics 204
6
182
PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING
Managing System Alarms 205
Viewing and Clearing Current Alarms 205
PathBuilder S700 Alarm Messages 207
MCPU and STX Module (System) Alarms 207
Alarms Common to Several Modules 211
DS1/E1 UNI Module Alarms 213
DSX-1/E1 CBR Module Alarms 218
QSIM/FAM Alarms 219
Working with History Alarms 219
Viewing and Printing History Alarms 219
Clearing History Alarms 220
Using Loopbacks 220
DS3 UNI Module Loopbacks 222
E3 UNI Module Loopbacks 222
OC3/STM-1 UNI Module Loopbacks 223
DSX-1 CBR Module Loopbacks 224
FAM Loopbacks 224
DS1/E1 UNI with IMA Module Loopbacks 225
Viewing Statistics 225
Card Statistics Overview 225
Performance Statistics Overview 225
ATM Statistics Overview 226
Virtual Circuit Statistics Overview 227
Viewing Card Statistics 227
Viewing DS3 UNI Module Statistics 228
Viewing E3 UNI Module Statistics 229
Viewing OC3/STM-1 UNI Module Statistics 230
Viewing DS1 UNI and E1 UNI with IMA Module Statistics
Viewing Ethernet Module Statistics 235
Viewing DSX-1 and E1 CBR Module Statistics 237
Viewing QSIM/HSIM/FAM Statistics
238
Viewing Virtual Circuit Statistics 241
Viewing Virtual Circuit Statistics by Circuit 241
Conforming/Non-Conforming Cell Counters 243
Viewing Virtual Circuit Statistics by Port/Group 244
A
TECHNICAL SUPPORT
Online Technical Services 247
World Wide Web Site 247
3Com FTP Site 247
3Com Bulletin Board Service 248
Access by Analog Modem 248
Access by Digital Modem 248
3ComFacts Automated Fax Service 248
Support from Your Network Supplier 248
Support from 3Com 249
Returning Products for Repair 250
INDEX
3COM CORPORATION LIMITED WARRANTY
232
WARNING INFORMATION
This section contains warning information for AC powered systems.
Servicing
Service of this unit is to be performed by qualified service personnel only.
Service of certain components and subassemblies in this equipment is
accomplished by the replacement of Field Replaceable Units (FRUs). However,
safety agency approval requires that the servicing of other subassemblies within
this product be referred to 3Com’s service personnel.
The trim enclosure and other mechanically secured plates serve as protection
barriers from potential hazardous internal areas. No attempt should be made to
troubleshoot internal components with these protective barriers removed
without first disconnecting the equipment from main power.
Rack Mounting
This equipment is for use only in complete equipment where the acceptability of
the combination is determined by the applicable safety agency in the country in
which it is installed. This includes UL in the U.S.A., CSA in Canada, and TUV in
Europe.
Conditions of Acceptability: When installed in the end-use equipment, the
following are among the considerations to be made.
1 The units shall be installed in compliance with enclosure, mounting, spacing,
casualty, and segregation requirements of the ultimate application.
2 These units have been judged on the basis of the required spacings of UL 1950
D3 deviations edition, CSA 22.2 No. 950-M89, and EN 60950 1988 through
TUV Rheinland, which would cover these components if submitted for
unrestricted listing or certification.
3 Complete testing should be performed in the end-use product.
4 Rack configurations with certain combinations of 3Com equipment installed in
racks with a height greater than 50” (127 cm) may require a counter-balance
weight, a stabilizer bar, or anti-tip legs to ensure rack stability in accordance
with safety agency regulations. See specific rack installation guidelines for 3Com
recommendations.
Power and Power
Cords
This equipment is not intended for use with IT power distribution systems
whose line to line voltage exceeds 250 VAC RMS defined by EN 60950 as
having no direct connection to earth. The PathBuilder S700 WAN Access Switch
will autoconfigure for 115 VAC or 220-240 VAC.
x
CHAPTER : WARNING INFORMATION
NORTH AMERICAN APPLICATIONS: Use a UL Listed and CSA Certified Cord Set
rated 12 amps, consisting of a minimum 10 AWG, Type SVT or SJT three
conductor cord maximum of 15 feet in length, with a NEMA 5-15P plug.
INTERNATIONAL APPLICATIONS: The power supply cords used with this
equipment should be harmonized with all local standards applicable in the
country in which it is installed.
Safety agency compliance requires this unit to be connected to branch circuits
with overcurrent protection £ 20A for North American applications and £ 10A
for international applications.
The power supply cord must be disconnected when servicing all components or
subsystems.
EMI
FCC - This equipment generates, uses, and can radiate radio frequency energy,
and if not installed and used in accordance with the instruction manual, may
cause interference to radio communications. It has been tested and found to
comply with the limits for a Class A computing device pursuant with Part 15 of
the FCC Rules, which are designed to provide reasonable protection against
such interference when operated in a commercial environment. Operation of
this equipment in a residential area is likely to cause interference, in which case
the user at his own expense will be required to take whatever measures may be
required to correct the interference. These tests were conducted with shielded
communications cables with metal connector hoods; the use of unshielded
cables may void this compliance.
Canada - This digital apparatus does not exceed the Class A limits for radio
noise emissions from digital apparatus set out in the Radio Interference
Regulations of the Canadian Department of Communications.
Europe - This is a Class A product. In a domestic environment this product may
cause radio interference, in which case, the user may be required to take
adequate measures.
Safety Classification
of Ports for
Connection to
Telecommunications
Networks
The following port types in the product range are classified according to the
Harmonized Europeans Standard EN41003, subclause 4.1.3, as follows:
E1/E3 - TNV normally operating within SELV limits (TNV-1)
1Telecommunications
2Safety
Network Voltage (EN60950, subclause 1.2.8.8)
Extra-Low Voltage (EN60950, subclause 1.2.8.5)
SUPPLEMENTARY REGULATORY
INFORMATION
This section provides information about host chassis/module compatibility and
creepage/clearance requirements. It also describes the compliance of the
PathBuilder S700 WAN access switch (Pathbuilder S700) with FCC and CE
regulations.
Host Chassis/Module
Compatibility and
Creepage/Clearance
Requirements
The installer of the E1 CBR and E3 UNI Module must ensure that the host
chassis and module are compatible and that the host chassis is capable of
providing adequate power to the module and any other auxiliary host apparatus.
The E1 CBR Module has the following input power requirements:
+5 vdc @ 3.6 Amps
The E3 UNI Module has the following input power requirements:
+5 vdc @ 3.0 Amps
Please contact 3Com for an up-to-date list of compatible host chassis.
In order to maintain the independent approval of this card, it must be installed
in such a way that with the exception of the connections to the host, when
other option cards are introduced which use or generate a hazardous voltage,
the minimum creepages and clearances specified in the table below are
maintained. A hazardous voltage is one which exceeds 42.2V peak AC or 60V
DC.
If you have any doubt, seek advice from a component engineer before installing
other adapters into the test equipment.
Voltage Used or Generated by Host
or Other Cards
Clearance (mm)
Creepage (mm)
2.0
2.4 (3.8)
2.6
3.0 (4.8)
Up to 59 Vrms or Vdc
Up to 125 Vrms or Vdc
4.0
5.0 (8.0)
Up to 250 Vrms or Vdc
4.0
6.4 (10.0)
Up to 300 Vrms or Vdc
For a host or other expansion card fitted in the Above 300 Vrms or Vdc
host, using or generating voltages greater than
300V (rms or dc), advice from a competent
telecommunications safety engineer must be
obtained before installation of this card.
The larger distance shown in parentheses in the table above applies where the
local environment within the host is subject to conductive pollution or dry
non-conductive pollution which could become conductive due to condensation.
Failure to maintain these minimum distances would invalidate the approval.
xii
CHAPTER : SUPPLEMENTARY REGULATORY INFORMATION
Clearance (distance X in the figure below) is defined as the shortest distance
between two conductive parts, or between the conductive part and the bonding
surface of the equipment, measured through air.
Creepage (distance Y in the figure below) is defined as the shortest path
between two conductive parts, or between the conductive part and the bonding
surface of the equipment, measured along the surface of the insulation.
Y
Host Chassis
X
Components
Interface Module
FCC Part 68 Statement
Adjacent Card
This equipment complies with Part 68 of the Federal Communications
Commission (FCC) rules. On the product is a label that contains the FCC
registration number for this device. If requested, you must provide this
information to the telephone company.
This equipment is designed to be connected to the telephone network or
premises wiring using a compatible modular jack which is Part 68 compliant.
See installation instructions for details.
If this device causes harm to the telephone network, the telephone company
will notify you in advance that temporary discontinuance of service may be
required. The telephone company may request that you disconnect the
equipment until the problem is resolved.
The telephone company may make changes in its facilities, equipment,
operations, or procedures that could affect the operation of this equipment. If
this happens, the telephone company will provide advance notice in order for
you to make necessary modifications to maintain uninterrupted service.
If you experience trouble with this equipment or for repair or warranty
information, please follow the applicable procedures explained in the Technical
Support section of this manual (Appendix A).
CE Notice
Marking by the symbol CE indicates compliance of the equipment with the
EMC, Telecom and Low Voltage directives of the European Community. Such
marking is indicative that this equipment meets or exceeds the following
technical standards.
EN55022—Limits and methods of measurement of radio interference
characteristics of information technology equipment.
EN50082-1—Electromagnetic compatibility - generic immunity standard part 1:
residential, commercial, and light industrial.
CTR 12—Connection of 2 Mbit/s Unstructured Leased Lines.
CTR13—Connection to 2 Mbit/s Structured Leased Lines.
EN 60950—Safety of Information Technology Equipment including Electrical
Business Equipment.
EN 41003—Particular safety requirements for electrical equipment to be
connected to Telecom networks.
WARNING: This customer equipment is to be installed and maintained by
service personnel as defined by AS/NZS 3260 clause 1.2.14.3. (Service
Personnel). Incorrect connection of connected equipment to the General
Purpose Outlet could result in a hazardous situation.
WARNING: Safety requirements are not fulfilled unless the equipment is
connected to a wall socket outlet with protective earth contact.
xiv
CHAPTER : SUPPLEMENTARY REGULATORY INFORMATION
ABOUT THIS GUIDE
About This Guide provides an overview of this guide, describes guide conventions,
tells you where to look for specific information and lists other publications that
may be useful.
Introduction
Audience Description
This guide describes how to install and configure the PathBuilder S700 WAN
access switch (PathBuilder S700). It also provides an overview of the unit’s modules
and supported applications.
This guide is intended for network administrators, system engineers, field
engineers, and other personnel responsible for installing, configuring, and
managing PathBuilder products.
If the information in the Release Notes shipped with your product differs from the
information in this guide, follow the Release Notes.
How to Use This Guide
Table 1 shows where to find specific information in this guide.
Table 1 Where to Find Specific Information
If you are looking for...
Turn to...
Descriptions of the features and benefits of the PathBuilder S700
Chapter 1
System specifications
Chapter 1
Installation instructions
Chapter 2
Information about how to get started using the PathBuilder S700
Chapter 3
Instructions for using the PathBuilder S700 menus
Chapter 3
Information about the specific modules and applications you can use with
the PathBuilder S700
Chapter 4
Instructions for configuring PathBuilder S700 modules, ports, and cards
Chapter 5
Instructions for configuring virtual interfaces
Chapter 5
Instructions for configuring shapers
Chapter 5
Instructions for configuring virtual circuits
Chapter 5
Instructions for configuring bridging applications
Chapter 5
Information about managing system alarms and lists of the alarms
supported by the PathBuilder S700
Chapter 6
Information about setting up loopbacks and what loopbacks specific
modules support
Chapter 6
Information about displaying statistics and lists of the types of statistics
available for specific modules
Chapter 6
Technical support information
Appendix A
2
ABOUT THIS GUIDE
Conventions
Table 2 and Table 3 list conventions that are used throughout this guide.
Table 2 Notice Icons
Icon
Notice Type
Alerts you to...
Information note
Important features or instructions
Caution
Risk of personal injury, system damage, or loss of data
Warning
Risk of severe personal injury
Table 3 Text Conventions
Convention
Description
Syntax
The word “syntax” means you must evaluate the syntax provided and
supply the appropriate values. Placeholders for values you must supply
appear in angle brackets. Example:
Enable RIPIP by using the following syntax:
SETDefault !<port> -RIPIP CONTrol = Listen
In this example, you must supply a port number for <port>.
Commands
The word “command” means you must enter the command exactly as
shown in text and press the Return or Enter key. Example:
To remove the IP address, enter the following command:
SETDefault !0 -IP NETaddr = 0.0.0.0
This guide always gives the full form of a command in uppercase and
lowercase letters. However, you can abbreviate commands by entering
only the uppercase letters and the appropriate value. Commands are
not case-sensitive.
Screen displays
This typeface represents information as it appears on the screen.
The words “enter”
and “type”
When you see the word “enter” in this guide, you must type
something, and then press the Return or Enter key. Do not press the
Return or Enter key when an instruction simply says “type.”
[Key] names
Key names appear in text in one of two ways:
n
Referred to by their labels, such as “the Return key” or “the Escape
key”
n
Written with brackets, such as [Return] or [Esc].
If you must press two or more keys simultaneously, the key names are
linked with a plus sign (+). Example:
Press [Ctrl]+[Alt]+[Del].
Menu commands
and buttons
Menu commands or button names appear in italics. Example:
Words in italicized
type
Italics emphasize a point or denote new terms at the place where they
are defined in the text.
Words in bold-face
type
Bold text denotes key features.
From the Help menu, select Contents.
Related Documentation
Related
Documentation
3
In addition to this guide, the following documentation may help you use the
PathBuilder S700.
PathBuilder S700 Release Notes—Provides configuration help and information
about new features and any known limitations and issues found in the release.
PathBuilder Switch Manager User Guide—Describes how to use PathBuilder
Switch Manager to configure and manage PathBuilder WAN access switches.
Using PathBuilder Switch Manager, you can configure shelf, device, and circuit
information; use a loopback panel to diagnose port cards; view line and interface
statistics; and perform administrative functions such as configuring trap
destinations and setting SNMP community strings.
4
ABOUT THIS GUIDE
1
SYSTEM DESCRIPTION
This chapter describes the PathBuilder S700 WAN access switch (PathBuilder
S700), and lists PathBuilder S700 system specifications. It includes the following
sections:
Introducing the
PathBuilder S700
PathBuilder S700
Features
n
Introducing the PathBuilder S700
n
Specifications
n
Options and Parts List
The PathBuilder S700 is a next-generation multiservice platform that provides
adaptation, concentration, and switching of a wide variety of traffic onto
high-speed ATM links. Delivering sophisticated data, voice and video adaptation,
and traffic management capabilities, the PathBuilder S700 WAN access switch is
an ideal platform both for service providers (to provision low-speed multiservice
services) and for enterprise users (to build converged networks).
The PathBuilder S700 provides the following key features:
n
Scalability—18 slots, with 14 slots for application modules, supporting a
maximum of 96 (rear access) or 112 (front access) T1 or E1 ports, 14 DS3 or E3
ports, or 14 OC3/STM-1 ports.
n
High ATM backplane capacity—3.2 Gbps
n
Supports proven technology—queuing, buffering, traffic shaping, traffic
policing, early packet discard, and multicasting. See “Key Features of the STX
Module” below for details.
n
Resiliency—supports load-sharing power supplies, hot-swappable common
components (MCPU and STX), and application modules; selected rear
redundant application modules are available; common component and
application module redundancy will be supported in subsequent releases.
n
Legacy module support—use existing PathBuilder S600 application modules
in the PathBuilder S700.
n
Rear cable access—rear access modules designed specifically for the
PathBuilder S700; available now for T1/E1 and DS3/E3 application modules.
Key Features of the STX Module
The STX module includes a switching fabric that provides sophisticated traffic
management, priority queuing, and multicasting. Once an application module
SARs its traffic into ATM cells, the STX receives the cells and performs address
lookup for switching, queuing, traffic shaping, traffic policing, early packet
discard, and multicasting.
6
CHAPTER 1: SYSTEM DESCRIPTION
The STX module provides the following features:
PathBuilder S700
Architecture
n
Any-to-any port switching
n
Virtual interfaces (VIs); logical UNI ports that provide traffic shaping profiles
(127 total VIs allowed: 24 per triple-slot bus (7-9, 10-12, 13-15, 16-18), 15 per
slot for slots 5 and 6, 1 for MCPU)
n
Deep buffers for queuing (8,000 cells per VI for a total of over 1 million cells
buffered per shelf)
n
Priority queuing in which each VI can be assigned to specific VCs which can be
allocated to one of 4 queues
n
Per VC traffic policing
n
Multicasting (up to 256 connections with 32 leaves)
n
Bipolar Timing Source (BITS) timing clock
n
Per VC statistics
n
4,000 connections per unit
The modular architecture of the PathBuilder S700 is designed to accommodate a
wide range of interfaces and support a comprehensive set of applications. The
core component of the unit is a 3.2 Gbps cell bus backplane where all traffic is
carried in the form of ATM cells. The PathBuilder S700 accommodates up to six
power supplies (AC 110/220 VAC and DC-48 VDC) in a load-sharing
configuration.
The overall design philosophy of the PathBuilder S700 is to facilitate the transfer of
cells on and off the bus backplane with enhanced traffic management and
switching capabilities. Figure 1 illustrates the cell bus architecture. All
packet-to-cell segmentation and reassembly (SAR) functions are performed on
each of the application modules (Ethernet, Frame Relay, and CBR), thereby
ensuring efficient cell transfer through the system. Additional SAR power is added
each time a non-ATM interface module is added.
Figure 1 PathBuilder S700 Cell Bus Architecture
10BaseT(2)
V.35(4), HSSI(1), T1(8)
T1/E1(4/8)
T1/E1(with integral IMA),
DS3/E3, OC3/STM-1
Ethernet
Frame
Relay
CBR
ATM
STX
MCPU
10BaseT,RS232, SLIP
Introducing the PathBuilder S700
7
Because the STX module allows any-to-any port switching, there is no distinction
between port and trunk modules for the PathBuilder S700. Thus, the slot
assignments are as follows:
n
Slot 1 contains the Management CPU (MCPU). This slot is permanently
allocated. The MCPU manages the configuration database, network
management (via Text User Interface and SNMP), and software download
capabilities.
n
Slot 3 contains the STX Module. This slot is permanently allocated.
Slots 2 and 4 are reserved for redundant MCPU and STX modules, which will be
supported in subsequent releases.
n
Slots 5-18 contain the application modules.
Each module incorporates an RISC-based processor for processing packets/cells,
communication information, and statistics.
The S700 supports selected rear redundant application modules (T1/E1 and
DS3/E3). You can use front connector modules (identical to those used in the
PathBuilder S600) as well as the rear redundant modules, but only the rear
connector types will support the redundant operation available in subsequent
releases.
The S700 supports the following ATM and application modules:
n
DS3 UNI module (front or rear connector)
n
E3 UNI module (front or rear connector)
n
OC3/STM-1 UNI module (front connector)
n
DS1 UNI with Inverse Multiplexing for ATM (IMA) (front or rear connector)
n
E1 UNI with Inverse Multiplexing for ATM (IMA) (front or rear connector)
n
Dual Ethernet module (front connector)
n
DSX-1 CBR (Constant Bit Rate) module (4 port or 8 port) (front or rear
connector)
n
E1 CBR (Constant Bit Rate) module (4 port or 8 port) (front or rear connector)
n
QSIM (Quad Serial Interface Module) (QSIM) - V.35/RS422/EIA530/X.21 (front
connector)
n
HSIM (HSSI Serial Interface Module) (front connector)
n
DS1 FAM (Frame Access Module) - (front connector)
8
CHAPTER 1: SYSTEM DESCRIPTION
Specifications
Table 4 lists complete specifications for the Pathbuilder S700. these specifications
are subject to change without notice.
Table 4 PathBuilder S700 System Specifications
Platform
Configuration
18 slots per shelf
Power Supplies
Up to 6 required depending on number of application modules
installed (load sharing configuration)
Input Power Requirements 90-264 VAC, 50-60Hz standard grounded outlet
-42 to -60 VDC, optional
10 AWG wire, Belden type 19364
Power Consumption
1250 Watts, maximum
Maximum Current
10.0 A @ 110 VAC
5.0 A @ 220 VAC
20.0 A @ -48 VDC
Environmental
Operating Temperature
0 to 45ºC
Storage Temperature
-40 to 70ºC
Humidity
95% @ 40ºC (noncondensing)
Altitude
14,000 ft. or 4,300 meters
Regulatory Compliance
FCC
FCC Part 15 rules for a Class A computing device
FCC Part 68
Emissions
EN55022
EN50082-1
CTR 12
CTR 13
Austel TS-001
Austel AS 3260
Safety
UL listed (UL 1950 and 1459)
VDE/TUV (EN 60950)
EN41003
CSA 22.2
Austel AS/NZS35-48
Physical
Shelf Dimensions
22.75” x 19” x 11.81” (H x W x D)
(57.8 cm x 48.3 cm x 30 cm)
Rack Mount Width
19” (48.3 cm) or
23” (58.4 cm) optional
Rack Mount Spacing
13 RMU
Empty Weight (Base Unit)
62 lbs (28.1 kg)
Unit Weight (fully loaded)
95 lbs (43.1 kg)
Shipping Weight
100 lbs (45.4 kg)
Management
Management Functions
(continued)
In-band SNMP (See “Configuring In-band Management” in
Chapter 3 for details.)
Dual flash memory (image and configuration) TCP/IP stack (TFTP,
ping, Telnet)
Specifications
9
Table 4 PathBuilder S700 System Specifications (continued)
SNMP Support
GET/SET/TRAP
RFC 1213 (MIB II)
RFC 1406 (DS1/E1)
RFC 1407 (DS3/E3)
RFC 1493 (Bridge MIB)
RFC 1643 (Ethernet MIB)
RFC 1595 (SONET MIB)
ATM Forum CES MIB
Enterprise Specific MIB
Statistics
Frames received, transmitted, and discarded (per port and per VC)
Standards Compliance
ATM Forum UNI 3.0, UNI 3.1
ATM Forum Circuit Emulation Service Interoperability
Specification V 2.0
ATM FORUM Inverse Multiplexing for ATM (IMA) Specification
Version 1.0
ANSI T1.107, 1988
ANSI T1.403
ANSI T1.403
ANSI T1.403
RFC 1483, 1490
RFC 826
RFC 1042
RFC 1577
IEEE 802.1
IEEE 802.3
AT&T PUB 54016
AT&T PUB 62411
ITU-T G.821
ITU-T G.703
ITU-T G.704
Frame Relay Forum Specifications 5 and 8
ATM User-to-Network Interface (UNI) Modules
Interfaces
DS3 UNI
Coax, BNC
E3 UNI
Coax, BNC
OC3 UNI
MMF/SMF, SC
STM-1 UNI
MMF/SMF, SC
ATM Framing
DS3 UNI
HEC, PLCP
E3 UNI
HEC, PLCP
OC3 UNI
HEC
STM-1 UNI
HEC
LBO
DS3 UNI
0-250, 250-450
E3 UNI
0-250, 250-450
(continued)
10
CHAPTER 1: SYSTEM DESCRIPTION
Table 4 PathBuilder S700 System Specifications (continued)
OC3 UNI
Single-mode
300 Laser (SDX1155)
wavelength: 1261 nm-1360nm
TX (min) = -15 dBm
TX (max) = -8 dBm
RX (min = -30 dBm
RX (max) = -8 dBm
Reach: -15 km
wavelength: 1261 nm-1360nm
TX (min) = -15 dBm
Multi-mode
1300 LED (HFBR-5205)
TX (min) = -19 dBm
TX (max) = -14 dBm
RX (min = -30 dBm
RX (max) = -14 dBm
Reach: -2 km
Line Coding
DS3 UNI
B3ZS
E3 UNI
HDB3
OC3 UNI
CMI
STM-1 UNI
CMI
Line Framing
DS3 UNI
M23 and C-BIT
E3 UNI
G.751-PLCP / G.804 / G.832 for HEC
OC3 UNI
T1.105
STM-1 UNI
G.709
Class of Service
CBR, VBR, VBR-nrt, UBR
Virtual Circuits
Up to 4000 total per PathBuilder S700
Traffic Shaping
Bulk shaping
Per VC/VP shaping
Per VC shaping (Ethernet, FAM, QSIM, HSIM)
Traffic Policing
Per VC
DS1/E1 UNI with Integrated Inverse Multiplexing for ATM (IMA) Modules
Number of Interfaces
nx8,n = 1 to 8; software selectable for individual T1/E1 UNIs or as
logical IMA group (>1 link)
Connector Type
RJ-48 connectors
Integrated CSU
Yes (for DS1)
Line Coding
B8ZS for T1
HDB3 for E1
Line Framing
ESF, SF (D4), or No Framing for T1
G. 703/704 for E1
ATM Framing
HEC (ITU-T G.804), I.432
Payload Scrambling for E1
DSX-1/E1 Interface CBR Module
Interface
ATM Forum CES structured and unstructured (2.0)
Number of Interfaces
4 or 8
Connector Type
RJ-48, 120 ohms balanced or 75 ohms unbalanced
ATM Encapsulation
AAL1
(continued)
Specifications
11
Table 4 PathBuilder S700 System Specifications (continued)
Timing
SRTS, adaptive, loop, internal
Cell Delay Variation
Tolerance
24 msec (T1), 32 msec (E1)
Class of Service
CBR
VPI/VCI
Up to 192 per octal module
Up to 96 per quad module
Front Panel LEDs
Power, in-service, fail, test, active
Port in-service, port alarm
Ethernet LAN Interface Module
Interfaces
2 Ethernet/IEEE 802.3
Packet Forwarding
14,800 pps simultaneously on each interface
Packet Protocols
Learning bridge, 802.1d spanning tree, RFC 1577 forwarding,
RFC 1483
Filtering
MAC address, SAP, PID, user data field
Address Table Size
8192 entries (4096 per port)
ATM Protocols
AAL5, RFC 1483
Class of Service
VBR, UBR
VPI/VCI
Up to 512 per module
Traffic Shaping
Multiple levels with PCR, SCR, and MBS settings
Frame Data Modules
Interface
Up to 8 T1 120 ohm (FAM)
4 V.35, RS-449, EIA530, X.21(QSIM)
1 HSSI (HSIM)
Speeds (line rate)
T1 56/64 Kbps to 1.5 Mbps
V.35, RS-422/449 up to 8 Mbps each
HSSI @ 20 Mbps
Packet Protocols
Frame Relay (service and network interworking), ATM DXI,
HDLC/SDLC pass through
Clocking
DTE or DCE
DTE SDU
Up to 9232 octets
Class of Service
VBR, UBR (AAL5)
VPI/VCI
Up to 256 per module
Traffic Shaping
Multiple levels per VC, with PCR, SCR, MBS setting
12
CHAPTER 1: SYSTEM DESCRIPTION
Options and Parts List
Table 5 lists available PathBuilder S700 options including spare/redundant shelves,
port modules, trunk modules, system modules, and interface cables Contact
3Com or your VAR with the appropriate part number for ordering and pricing
information.
Table 5 Part Numbers and Descriptions
Part Number
Description
CHASSIS
3C63400-3AC-C
PathBuilder S700 Base System (Includes: chassis, S700 MCPU, S700
STX, 3 AC power supplies, cover panels, rack mount, reference
guide, RS-232 cable, and fan assembly)
3C63400-3DC-C
PathBuilder S700 Base System (Includes: chassis, S700 MCPU, S700
STX, 3 DC power supplies, cover panels, rack mount, reference
guide, RS-232 cable, and -48V fan assembly)
ACCESS AND APPLICATION MODULES
3C63101
Dual-Port Ethernet Modules (10BaseT) with bridging and RFC 1577
3C63103
Quad Serial Interface Module (4 Port V.35/RS449/RS530; DXI, Frame
Relay, SDLC/HDLC)
3C63104
HSSI Serial Interface Module (Single HSSI; DXI, Frame Relay,
SDLC/HDLC)
3C63105-4DSX
4-Port DSX-1 CBR Module
3C63405-4DSX
PathBuilder S700 Rear Redundant 4-Port DSX-1 CBR Module
3C63105-8DSX
8-Port DSX-1 CBR Module
3C63405-8DSX
PathBuilder S700 Rear Redundant 8-Port DSX-1 CBR Module
3C63105-4E1
4-Port E1 CBR Module
3C63405-4E1
PathBuilder S700 Rear Redundant 4-Port E1CBR Module
3C63105-8E1
8-Port E1 CBR Module
3C63405-8E1
PathBuilder S700 Rear Redundant 8-Port E1CBR Module)
3C63106A-DS3
DS3 UNI Single Port Module
3C63406-DS3
PathBuilder S700 Rear Redundant DS3 UNI Single Port Module
3C63106A-E3
E3 UNI Single Port Module
3C63406-E3
PathBuilder S700 Rear Redundant E3 UNI Single Port Module
3C63107A-MMF
OC3/STM-1 UNI Multi-Mode Module
3C63107A-SMF
OC3/STM-1 UNI Single-Mode Module
3C63114-8DS1
8-port T1 UNI with Integrated IMA Module
3C63414-8DS1
PAthBuilder S700 Rear Redundant 8-port T1 UNI with Integrated
IMA Module
3C63114-8E1
8-port E1 UNI with Integrated IMA Module
3C63414-E1
PathBuilder S700 Rear Redundant 8-port E1 UNI with Integrated IMA
Module
3C63115-8DS1
8-port FT1/T1 Frame Access Module (FAM)
3C63415-8DS1
PathBuilder S700 Rear Redundant 8-port FT1/T1 Frame Access
Module (FAM)
(continued)
Options and Parts List
13
Table 5 Part Numbers and Descriptions (continued)
Part Number
Description
OPTIONAL AND SPARE ITEMS
3C63111A-AC
Optional 110V/220V AC Power Supply
3C63111A-DC
Optional -48V DC Power Supply
3C63112
Spare Fan Assembly
3C63113-BPM
Blank Panel for Module Slots
3C63408
PathBuilder S700 MCPU System Controller Module
3C63416
PathBuilder S700 STX Switching Module
3C63410-3AC
PathBuilder S700 chassis (includes: chassis, fan assembly, and 3 AC
power supplies)
3C63410-3DC
PathBuilder S700 chassis (includes: chassis, fan assembly, and 3 DC
power supplies)
3C64917
Additional PathBuilder S700 User Documentation (Release 2.x)
CABLES
3C63911
Coax Cable; BNC to BNC - 8M/25Ft
3C63912
HSSI Cable; 50-Pin Male, Straight, to Male 50-Pin - 8M/25Ft
3C63915
RS232 Cable; RS232 DB9 Male, Crossover, to RS232 DB9 Female 2M/6Ft
3C63902
DS1/E1 Cable; RJ48, Shielded Straight, to RJ48 - 8M/25Ft
3C63903
DS1/E1 Cable; RJ48, Shielded Crossover, to RJ48 - 8M/25Ft
3C63904
E1 Balun Adapter; RJ48 120 ohm to Coax 75 ohm - 2M/6Ft
3C63905
Fiber Cable; SC, Multi-mode, to SC 8M/25Ft
3C63906
Fiber Cable; SC, Multi-mode, to FC 8M/25Ft
3C63907
Fiber Cable; SC, Multi-mode, to ST 8M/25Ft
3C63908
Fiber Cable; SC, Single-mode, to SC 8M/25Ft
3C63909
Fiber Cable; SC, Single-mode, to FC 8M/25Ft
3C63910
Fiber Cable; SC, Single-mode, to ST 8M/25Ft
3C63913
V.35 Cable; HD 60-Pin Male to V.35 34-Pin Male, 2M/6Ft (Crossover
DTE)
3C63914
V.35 Cable; HD 60-Pin Male, Straight, to V.35 34-Pin Female, 2M/6Ft
3C63921
RS449 Cable; HD 60-Pin Male to RS449 Female (DCE), 2M/6Ft
3C63920
RS449 Cable; HD 60-Pin Male to RS449 Male (DTE), 2M/6Ft
3C63923
EIA530 Cable; HD 60-Pin Male to EIA530 Male (DTE), 2M/6Ft
3C63922
EIA530 Cable; HD 60-Pin Male to EIA530 Female (DCE), 2M/6Ft
3C63924
X.21 DTE Cable (HD 60-pin male straight to X.21 15-pin male)
3C63925
X.21 DCE Cable (HD 60-pin male straight to X.21 15-pin female)
14
CHAPTER 1: SYSTEM DESCRIPTION
2
INSTALLATION
This chapter tells you how to mechanically and electrically install the
PathBuilder S700 WAN access switch (PathBuilder S700) in your network. It
contains the following sections:
n
Receiving and Inspecting the PathBuilder S700
n
Installation Overview
n
Step 1: Install the Shelf in the Rack
n
Step 2: Connect AC or DC Power
n
Step 3: (If needed) Install Additional Modules in the Shelf
n
Step 4: Connect I/O Cabling and Wiring
n
Step 5: Connect a Management Terminal
Before using the chapter for an actual installation, read through it at least once to
familiarize yourself with the overall process.
Receiving and
Inspecting the
PathBuilder S700
When you receive the PathBuilder S700, unpack it and inspect the unit for any
damage that might have occurred during shipment. Inventory the equipment
against the shipping notice.
Save the boxes and packing materials in the event there is damage or anything
needs to be reshipped at a future date. If anything is damaged or missing, contact
the shipper and 3Com immediately.
CAUTION: Many of the integrated circuits on the modules are sensitive to static
electricity. Do not remove the plug-in modules from their shelves without wearing
a properly grounded, antistatic, wrist strap.
Installation Overview
Figure 2 summarizes the overall installation procedure for the PathBuilder S700.
For details about each step in the overall procedure, see the following sections.
16
CHAPTER 2: INSTALLATION
Figure 2 General Installation Procedure
Prepare the site:
Site Requirements
Step 1: Install the
Shelf in the Rack
Verify clearances around the shelf site
Fabricate and run cabling and wiring
Prepare AC or DC power run
(install fuse and alarm panel)
Step 1
Install the shelf in the rack
Step 2
Connect AC or DC power
Step 3
(If needed) Install additional
modules in the shelf and
monitor front-panel LEDs
Step 4
Connect I/O cabling and wiring
and verify LEDs:
Application modules
Office alarms
BITS clock
Step 5
Connect a VT100 terminal for
local management access
n
Be within the maximum distances to the port and trunk connections, as well as
the NMS terminal
n
Have interconnect cabling and wiring ready and labeled
n
Have a dedicated source of switched and fused AC power.
n
Provide clearance for making all connections and performing maintenance.
In a normal rack mount configuration the PathBuilder S700 shelf is 22.75" x 19" x
11.81" including cables. If the PathBuilder S700 is mounted in an enclosure, plan
on enough clearance at the front and back for cable and wiring service loops.
CAUTION: The PathBuilder S700 chassis includes a fan tray, and a minimum gap
of one RU (rack unit) is required between the chassis and any convection cooled
equipment.
CAUTION: Many of the integrated circuits on the modules are sensitive to static
electricity. Do not handle the plug-in modules without wearing a properly
grounded, antistatic, wrist strap. When removing the modules from the shelf,
place them printed-circuit side down on a nonconducting, static-free, flat surface.
Step 2: Connect AC or DC Power
17
To install the unit in the rack using 19” or 23” mounting ears, follow these steps:
1 Adjust the mounting ears, if necessary, for 19" or 23” installation. Figure 3
illustrates the dimensions for a rack-mount installation.
Figure 3 Rack Mounting Ear Configurations
19" or 23"
!
Caution:
One rack unit
space required
above and below
the unit for clearance.
13 Rows 22.75"
PathBuilder S700
2 Support the shelf in its mounting place and attach the mounting hardware.
CAUTION: Since a fully-loaded chassis weighs 95 pounds, we recommend that
two people install the unit in the rack.
Step 2: Connect AC or
DC Power
AC/DC power connections are located at the rear of the PathBuilder S700 shelf.
Table 6 lists the specifications for the AC/DC Source.
Table 6 AC/DC Source Specifications
Input Power
Requirements
90-264 VAC, 50-60Hz, standard grounded
outlet
-42 to -60 VDC, Optional
10 AWG wire, Belden type 19364
Power Consumption
1250 Watts, Max
Maximum Current
10.0 A @ 110VAC
5.0 A @ 220VAC
20.0 A @ -48VDC
18
CHAPTER 2: INSTALLATION
3Com recommends that AC/DC power and office alarms be connected through a
Fuse and Alarm Panel mounted above the PathBuilder S700.
The PathBuilder S700 supports six load-sharing power supplies and requires a
minimum of three power supply modules for operation. Table 7 indicates how
many I/Os (network or user interfaces) are supported based on the number of
power supplies and the shelf configuration: non-redundant (1 MCPU module and
1 STX module) or redundant (2 MCPU modules and 2 STX modules),
The redundant configuration (2 MCPU modules and 2 STX modules is not
supported in Release 2.03 but will be in subsequent releases.
Table 7 Power Supply Requirements
Total # of
Power Supply Maximum # of I/Os
Maximum # of I/Os
Modules
(Non-Redundant System (Redundant System)
3
5
4
4
8
7
5
11
11
6
14
14
To make AC/DC power connections, follow these steps:
1 Plug the power supply modules directly into the backplane of the shelf. Their low
voltage DC outputs are bussed across the backplane to the other modules. Make
sure that the power supply modules and the fan tray are in the shelf and that they
are fully seated in their backplane connectors.
CAUTION: Before servicing the unit and handling AC/DC power leads, disconnect
all power supply cords. Always have a partner close by who is familiar with first aid
for electrical shock.
WARNING: DC Units are to be installed only in Restricted Access Areas (dedicated
equipment rooms, equipment closets, etc.) in accordance with Articles 110-16 or
110-17, and 110-18 of the National Electrical Code, ANSI/NFDA No.70.
2 Turn off the AC/DC power source and connect the AC/DC leads to the front of the
shelf. Dress the leads to the rack leaving a service loop.
3 Turn on the AC/DC power and verify that the POWER indicators on both Power
Supply Modules are on and that the fans are running.
Step 2: Connect AC or DC Power
19
Figure 4 illustrates the location of the AC power plugs and switch on the rear of
the unit.
Figure 4 PathBuilder S700 AC Power Input
TX RX
TX RX
TX RX
TX RX
AC
Power
Input
AC Switch
20
CHAPTER 2: INSTALLATION
Figure 5 illustrates the location and pinouts for the DC connector block on the rear
of the unit.
Figure 5 PathBuilder S700 DC Power Input
TX RX
TX RX
DC
Power
Input
Ð
+ GND
TX RX
TX RX
Step 3: (If needed) Install Additional Modules in the Shelf
Step 3: (If needed)
Install Additional
Modules in the Shelf
21
The PathBuilder S700 ships with the factory-ordered modules installed. If you have
ordered additional modules, install them as described in this section; otherwise,
proceed to “Step 4: Connect I/O Cabling and Wiring” for instructions on how to
connect the factory-installed modules and verify front panel indicators.
n
Install the Management CPU module in slot 1. (Slot 2 is reserved for a
redundant MCPU, which will be supported in subsequent releases.)
n
Install the STX module in slot 3. (Slot 4 is reserved for a redundant STX module,
which will be supported in subsequent releases.)
n
Install any one of the following application modules in slot 5-18:
n
DS3 UNI
n
E3 UNI
n
OC3/STM-1 UNI
n
DS1 UNI with IMA
n
E1 UNI with IMA
n
Ethernet
n
DSX-1 CBR
n
E1 CBR
n
QSIM (Quad Serial Interface Module)
n
HSIM (HSSI Module)
n
FAM (Frame Access Module)
To minimize reconfiguration of modules to implement future redundancy
capabilities, we recommend that you group similar modules in slots 7-11 or 12-16
and that you configure slots 17 and 18 last.
We recommend that you install OC3/STM-1 modules in slots 5 and 6 in order to
utilize their full bandwidth. Slots 5 and 6 provide 155 Mbps bandwidth for each
slot, while slots 7-18 share bandwidth (200 full-duplex Mbps for each group of
three slots: 7-9, 10-12, 13-15, and 16-18).
Slots 5 and 6 do not support rear redundant T1/E1 modules.
22
CHAPTER 2: INSTALLATION
Step 4: Connect I/O
Cabling and Wiring
This section tells you how to connect I/O cabling and wiring once the modules are
installed in the shelf and describes the common and module-specific front panel
LEDs.
Figure 6 shows an example of a PathBuilder S700 configuration with all of the
associated cabling connected.
Figure 6 Sample Full System Configuration
VT100 T
Initial Management
Connection to
Add an IP
Network
Address for LAN
Management
Management
Station
PathBuilder S700
PathBuilder
S700
Slot 1
Slot 18
n x T1 or E1
ATM
HSSI
Router
V.35
EIA530
RS-422
DS1/E1
Router
RX
In
DS3/E3
CSU or CPE
TX Out
DS3/E3
Service
LAN
TX Out
75 ohm coax
TX In
PathBuilder
S700
n x 64K
Frame Relay
OC3 UNI Multi-Mode
OC3 UNI Single-Mode
ATM
Router
Router
Step 4: Connect I/O Cabling and Wiring
Normal Startup
Sequence
23
All modules feature a set of common system LEDs on the top of the module.
When you install and connect a module, the common LED sequence shown in
Figure 7 occurs.
The Ethernet module, QSIM, and HSIM have only four common system LEDs.
These modules do not include the Active LED.
For descriptions of the LEDs specific to each module, see the following sections.
Figure 7 Common LED Sequence
1.
2.
3.
Slot 1
Slot 18
Power
Inservice
Fail
Test
Active
Upon
Power
Up
Power On
Tests
Completed
PathBuilder
S700
Power (PWR)—Indicates power from the power supply is good.
In Service (INS)—Indicates that the corresponding card is available for
transmission.
Fail—Indicates a sub-system failure.
Test—Indicates that a diagnostic is active.
Active (ACTV)—Indicates that the card is in service and active.
Connecting a DS3 UNI or
E3 UNI Module
Connect the DS3 UNI or E3 UNI module to a DS3 or E3 repeater using the female
BNC connectors, as shown in Figure 8. The maximum coax run is 450 feet for DS3
and 1200 feet for E3. The transmitter in the DS3 UNI Module includes selectable
LBO (Line Build-Out) to adjust the output signal to cable runs of 0-255 or 225-450
feet. Select the LBO during card configuration from the local terminal or NMS. See
“Configuring DS3 UNI Modules” in Chapter 5, for details.
The PathBuilder S700 supports two models of DS3/E3 UNI modules:
front-connecting modules, which you connect from the front of the unit, as
described in this section, and rear redundant modules, which you connect from
the rear of the unit. For details about how to connect rear redundant DS3/E3 UNI
modules, see “Connecting Rear Redundant Modules” later in this chapter.
24
CHAPTER 2: INSTALLATION
Figure 8 DS3/E3 UNI Module Connection
Slot 1
DS3/E3
CSU or CPE
Slot 18
TX Out
TX In
DS3/E3
Service
RX
In
TX Out
75 ohm coax
PathBuilder
S700
Once you have connected the module, verify the front-panel indicator sequence
illustrated in Figure 9. The DS3 UNI and E3 UNI modules feature the following
front panel indicators in addition to the common system LEDs:
LOS (RED)—Powers up in the “off” state and illuminates when a LOS (Loss of
Signal) condition is detected on the incoming DS3/E3. The LOS LED is off if a signal
is present. It reflects the LOS state of the DS3/E3 in real time (no integration of the
state is needed).
LOF (RED)—Powers up in the “off” state and illuminates when a LOF (Loss of
Frame) condition is detected on the incoming DS3/E3. The LOF LED is off when the
signal is in frame. It reflects the LOF state of the DS3/E3 in real time (no integration
of the state is needed).
LOCD (RED)—Powers up in the “off” state and illuminates when a LOCD (Loss of
Cell Delineation) condition is detected on the incoming DS3/E3 under HEC
(Header Error Control) framing. The LOCD LED is off when delineations are
obtained. It reflects the LOCD state of the DS3/E3 in real time (no integration of
the state is needed).
Step 4: Connect I/O Cabling and Wiring
Figure 9 DS3/E3 UNI Module LEDs
1.
2.
3.
Power
Slot 1
Inservice
Fail
Test
Active
LOS
LOF
LOCD
PathBuilder
Power
Up
Diagnostic
Running
Power On Test Complete
Good DS3 / E3 / OC3-STM-1
Good ATM Cell Delineation
S700
Slot 18
25
26
CHAPTER 2: INSTALLATION
Connecting an
OC3/STM-1 UNI Module
Connect the OC3/STM-1 UNI module using the Internal SC type connector. As
shown in Figure 10, the OC3-STM-1 UNI module supports two types of fiber optic
cable.
n
Use multi-mode cable to generate UNI traffic over a port interface.
n
Use single-mode cable to generate UNI traffic over a trunk interface.
Figure 10 OC3/STM-1 UNI Single-mode or Multi-mode Module Connection
Slot 1
PathBuilder
Slot 18
S700
OC3 UNI Multi-Mode
OC3 UNI Single-Mode
ATM
Once you have connected the module, verify the front-panel indicator sequence.
The startup LED sequence and module-specific LEDs for the OC3/STM-1 UNI
module are the same as those for the D3 UNI and E3 UNI module. See
“Connecting a DS3 UNI or E3 UNI Module” and Figure 9, earlier in this chapter, for
details.
Step 4: Connect I/O Cabling and Wiring
Connecting a DS1/E1
UNI with IMA Module
27
Connect the DS1 UNI with IMA module or the E1 UNI with IMA module using the
RJ-48 connectors (with integrated CSU for the DS1 module, with no CSU for the
E1 module), as shown in Figure 11.
The PathBuilder S700 supports two models of DS1/E1 UNI modules:
front-connecting modules, which you connect from the front of the unit, as
described in this section, and rear redundant modules, which you connect from
the rear of the unit. For details about how to connect rear redundant DS1/E1 UNI
modules, see “Connecting Rear Redundant Modules” later in this chapter.
If you are using a G703 coax physical connection to connect the E1 line to the
interface, you must use the E1 Balun Adapter (part number 3C63904) for proper
impedance.
Figure 11 DS1/E1 UNI with IMA Module Connection
Slot 1
ATM
Slot 18
DS1/E1
n x T1 or E1
PathBuilder
S700
PathBuilder S700
PathBuilder
S700
Once you have connected the module, verify the front-panel indicators. As shown
in Figure 12, the DS1/E1 UNI with IMA module features eight pairs of port
indicator LEDs in addition to the common system front panel indicators—each pair
corresponds to one of the eight RJ48 interfaces on the DS1/E1 UNI module.
28
CHAPTER 2: INSTALLATION
Figure 12 DS1/E1 UNI LEDs
Slot 1
PathBuilder
Connecting an Ethernet
Module
Slot 18
S700
n
The green indicator light illuminates to show that the port is in service.
n
The red indicator light illuminates to show that the port is not in service.
Connect an Ethernet module to the LAN directly or through a hub, as shown in
Figure 13, Table 8 lists the RJ48 connector pinouts.
Table 8 Ethernet Module Connector Pinouts
PIN 1
TX+
PIN 2
TX-
PIN 3
RX+
PIN 4
PIN 5
PIN 6
RX-
PIN 7
PIN 8
The cable runs from the PathBuilder S700 Ethernet ports to the Ethernet LAN
connections must be no longer than 100 meters in compliance with EIA/TIA
standards for 10BaseT. The cable lengths should include service loops at the ends
and the complete cable route distances.
Step 4: Connect I/O Cabling and Wiring
29
Figure 13 Ethernet Module Connection
Slot 1
Slot 18
LAN
PathBuilder
S700
Once you have connected the module, verify the front panel indicator sequence.
As shown in Figure 14, the Ethernet module has the following front panel
indicators in addition to the common system LEDs.
TX Port 1 (GREEN)—This is a transmit (to the cable) activity indicator. For each
frame sent to the cable, the LED is momentarily flashed.
RX Port 1 (GREEN)—This is a Receive (from the cable) activity indicator. For each
frame received from the cable, the LED will momentarily flash.
Link Port1 (GREEN)—This LED will illuminate when properly connected to the
Ethernet cable, otherwise it will be off.
TX Port 2 (GREEN)—This is a transmit (to the cable) activity indicator. For each
frame sent to the cable, the LED is momentarily flashed.
RX Port2 (GREEN)—This is a Receive (from the cable) activity indicator. For each
frame received from the cable, the LED will momentarily flash.
Link Port 2 (GREEN)—This LED will illuminate when properly connected to the
Ethernet cable, otherwise it will be off.
FWD (GREEN)—This is a bridging activity detector. For each frame bridged the
LED will momentarily flash.
ATM (GREEN)—This is an ATM traffic indicator. It illuminates when an ATM cell is
received or transmitted.
30
CHAPTER 2: INSTALLATION
Figure 14 Ethernet Module LEDs
Common System
1.
2.
Power
Inservice
Fail
Test
PathBuilder
S700
Bridge
Data If
Blinking
Fwd
Blinks
With
Data
Tx
Should
Be On
When
Properly
Connected
To 10BASE-T
Link
ATM
Rx
Tx
Rx
Link
Power
Up
Power On
Test Complete
Connecting a DSX-1 CBR
or E1 CBR Module
Connect a DSX-1 CBR or E1 CBR module using the RJ48 DSX-1 interface for T1/E1
traffic. Table 9 describes the DSX-1/E1 CBR connector pinouts.
Table 9 DSX-1/E1 CBR Connector Pinouts
PIN 1
RX ring
PIN 2
RX tip
PIN 3
NC
PIN 4
TX ring
PIN 5
TX tip
PIN 6
NC
PIN 7
NC
PIN 8
NC
The PathBuilder S700 supports two models of DSX-1/E1 CBR modules:
front-connecting modules, which you connect from the front of the unit, as
described in this section, and rear redundant modules, which you connect from
the rear of the unit. For details about how to connect rear redundant DSX-1/E1
CBR modules, see “Connecting Rear Redundant Modules” later in this chapter.
Step 4: Connect I/O Cabling and Wiring
31
If you are using a G703 coax physical connection to connect the E1 CBR line to the
interface, you must use the E1 Balun Adapter (part number 3C63904) for proper
impedance.
The DSX-1 CBR module supports LBOs (LIne Build Outs) to CSU of up to 655 feet.
You must configure the LBO via the local terminal or NMS. See “Configuring
DSX-1 CBR or E1 CBR Modules” in Chapter 5, for details. You can typically make
connections locally to DTE equipment without DSU/CSUs, as long as the
equipment supports a direct T1 interface and can recover T1 signal. See Figure 15.
Figure 15 DSX-1/E1 CBR Module Connections
PBX
DS1 Structured for DS0
Drop and Insert or
Unstructured for DS1
Tunneling
Channel
Bank
PathBuilder
S700
DSX-1 CBR
or
E1 CBR
You can make connections from the E1 CBR module locally to DTE equipment as
long as the equipment supports a direct E1 interface and can recover an E1 signal.
Once you have connected the DSX-1 CBR or E1 CBR module, verify the front panel
common LED sequence illustrated in Figure 16.
32
CHAPTER 2: INSTALLATION
Figure 16 DSX-1/E1 CBR Module LEDs
Slot 1
Slot 18
1.
Power
2.
3.
Common
System
Inservice
Fail
Test
Port is
Out of
Service
Active
Port is in
Service
PathBuilder
S700
Port has
OOF or LOS
Condition
(Out of
Service)
Port is in
Service with
OOF or LOS
Condition
As shown above in Figure 16, the DSX-1/E1 CBR module features eight pairs of
port indicator LEDs (four pairs for four-port CBR modules) in addition to the
common system front panel indicators—each pair corresponds to one of the ports
on the DSX-1/E1 CBR module.
n
The green indicator light illuminates to show that the port has been placed in
service.
n
The red indicator light illuminates to show an OOF or LOS condition on the
port.
Step 4: Connect I/O Cabling and Wiring
Connecting a QSIM
V.35/RS422/EIA530
Module
33
The QSIM (Quad Serial Interface Module) provides the following cabling options:
n
DTE/DCE V.35
n
DTE/DCE EIA530
n
DTE/DCE RS-422
n
DTE/DCE X.21
To connect the QSIM, attach the appropriate cable to one of the four ports using
the 60-pin amphenol connector, as shown in Figure 17.
Figure 17 QSIM Connection
V.35
EIA530
RS-422
Router
PathBuilder
S700
Table 10, Table 11, Table 12, Table 13, Table 14, Table 15, Table 16, Table 18, and
Table 17 describe the connector pinouts
34
CHAPTER 2: INSTALLATION
Table 10 V.35 DTE Cable (60-pin Male to 34-pin Male; Part # 3C63913)
Signal Name
Pin # on 60 Pin
Direction (For
Conn
Pin # on V.35 Conn QSIM)
Frame GND
46
A
Circuit GND
45
B
RTS
42
C
Out
CTS
35
D
In
DSR
34
E
In
DCD
33
F
In
DTR
43
H
Out
LL (not used)
44
K
Out
SD+
18
P
Out
SD-
17
S
Out
RD+
28
R
In
RD-
27
T
In
SCTE+
20
U
Out
SCTE-
19
W
Out
SCR+
26
V
In
SCR-
25
X
In
SCT+
24
Y
In
SCT-
23
AA
In
Shorting GR 1
48, 49
Shorting GR 2
50, 51, 52
Shorting GR 3
53, 54, 55, 56
Step 4: Connect I/O Cabling and Wiring
Table 11 V.35 DCE Cable Pinouts (60-pin Make to 34-pin Female; Part # 3C63914)
Signal Name
Pin # on 60 Pin
Direction (For
Conn
Pin # on V.35 Conn QSIM)
Frame GND
46
A
Circuit GND
45
B
RTS
35
C
In
CTS
42
D
Out
DSR
43
E
Out
DCD
44
F
Out
DTR
34
H
In
LL (not used)
33
K
In
SD+
28
P
In
SD-
27
S
In
RD+
18
R
Out
RD-
17
T
Out
SCTE+
26
U
In
SCTE-
25
W
In
SCR+
22
V
Out
SCR-
21
X
Out
SCT+
20
Y
Out
SCT-
19
AA
Out
Shorting GR 1
48, 49
Shorting GR 2
50, 51,
Shorting GR 3
53, 54, 55, 56
35
36
CHAPTER 2: INSTALLATION
Table 12 RS-422/449 DTE Cable Pinouts (60-pin Male to RS-449 male; Part # 3C63920)
Signal Name
Pin # on 60 Pin
Direction (For
Conn
Pin # on V.35 Conn QSIM)
Frame GND
46
1
Circuit GND
15, 16, 45
19, 20, 37
RTS
9, 10
7, 25
Out
CTS
1, 2
9, 27
In
DSR
3, 4
11, 29
In
DCD (not used, see
DCE cable)
5, 6
13, 31
In
DTR
7, 8
12, 30
Out
LL (not used)
44
10
Out
SD+
11
4
Out
SD-
12
22
Out
RD+
28
6
In
RD-
27
24
In
SCTE+
13
17
Out
SCTE-
14
35
Out
SCR+
26
8
In
SCR-
25
26
In
SCT+
24
5
In
SCT-
23
23
In
Shorting GR 1
48, 49
Shorting GR 2
51, 52,
Step 4: Connect I/O Cabling and Wiring
37
Table 13 RS422/449 DCE Cable Pinouts (60-pin Make to RS-449 Female; Part # 3C63921)
Signal Name
Pin # on 60 Pin
Direction (For
Conn
Pin # on V.35 Conn QSIM)
Frame GND
46
1
Circuit GND
15, 16, 30
19, 20, 37
RTS
1, 2
7, 25
In
CTS
9, 10
9, 27
Out
DSR
7, 8
11, 29
Out
DCD
5, 6
13, 31
Out
DTR
3, 4
12, 30
In
LL (not used)
29
10
In
SD+
28
4
In
SD-
27
22
In
RD+
11
6
Out
RD-
12
24
Out
SCTE+
26
17
In
SCTE-
25
35
In
SCR+
24
8
Out
SCR-
23
26
Out
SCT+
13
5
Out
SCT-
14
23
Out
Shorting GR 1
48, 49
38
CHAPTER 2: INSTALLATION
Table 14 EIA530 DTE Cable Pinouts (60-pin Male to EIA530 Male; Part # 3C63923)
Signal Name
Pin # on 60 Pin
Direction (For
Conn
Pin # on V.35 Conn QSIM)
Frame GND
46
1
Circuit GND
45
7
RTS
9, 10
4, 19
Out
CTS
1, 2
5, 13
In
DSR
3, 4
6, 22
In
DCD (not used, see
DCE cable)
5, 6
8, 10
In
DTR
7, 8
20, 23
Out
LL (not used)
44
18
Out
SD+
11
2
Out
SD-
12
14
Out
RD+
28
3
In
RD-
27
16
In
SCTE+
13
24
Out
SCTE-
14
11
Out
SCR+
26
17
In
SCR-
25
9
In
SCT+
24
15
In
SCT-
23
12
In
Shorting GR 1
47, 48, 49
Shorting GR 2
51, 52,
Step 4: Connect I/O Cabling and Wiring
39
Table 15 EIA530 DCE Cable Pinouts (60-pin Male to EIA530 Female; Part # 3C63922)
Signal Name
Pin # on 60 Pin
Direction (For
Conn
Pin # on V.35 Conn QSIM)
Frame GND
46
1
Circuit GND
45
7
RTS
1, 2
4, 19
In
CTS
9, 10
5, 13
Out
DSR
7, 8
6, 22
Out
DCD (not used, see
DCE cable)
5, 6
8, 10
Out
DTR
3, 4
20, 23
In
LL (not used)
29
18
In
SD+
28
2
In
SD-
27
14
In
RD+
11
3
Out
RD-
12
16
Out
SCTE+
26
24
In
SCTE-
25
11
In
SCR+
24
17
Out
SCR-
23
9
Out
SCT+
13
15
Out
SCT-
14
12
Out
Shorting GR 1
47, 48, 49
40
CHAPTER 2: INSTALLATION
Table 16 HSSI straight DTE to DCE Cable (50-pin Male to 50-pin Male; Part # 3C63912)
Signal Name
Pin # on DCE
Pin # on DTE
Direction (For DTE)
Circuit GND
1, 7, 13, 19, 25, 1, 7, 13, 19, 25, 26, 32,
26, 32, 38, 44, 38, 44, 50
50
TA
8, 33
8,33
Out
CA
3, 28
3, 28
In
LA
10, 35
10, 35
In
LB
12, 37
12, 37
In
LC
5, 30
5, 30
Out
SD
11, 36
11, 36
Out
RD
4, 29
4, 29
In
TT
9, 34
9, 34
Out
RT
2, 27
2, 27
In
ST
6, 31
6, 31
In
ST DTE
14, 39
14, 39
Out
Ancillary to DTE
(not used)
20, 21, 22, 23,
24, 45, 46, 47,
48, 49
20, 21, 22, 23, 24, 45,
46, 47, 48, 49
In
Ancillary to DCE 15, 16, 17, 18,
(not used)
40, 41, 42, 43
15, 16, 17, 18, 40, 41,
42, 43
Out
Step 4: Connect I/O Cabling and Wiring
Table 17 X.21 DTE Cable (60 pin Male to 15-pin Male; Part # 3C63924)
Signal Name
Pin # on
60 PIN CONN
Direction
Pin # on DB15 CONN (For QSIM)
Frame GND
46
1
Circuit GND
15
8
RTS
1, 2
3, 10
In
CTS
9, 10
5, 12
Out
DSR
Out
DCD (in order to keep
cable compatible with
Cisco, DCD should be
tristated when in DTE
mode.
Out
DTR
In
LL (not used)
In
SD+
28
2
In
SD-
27
9
In
RD+
11
4
Out
RD-
12
11
Out
SCTE+
In
SCTE-1
In
SCR+ (in order to keep 24
cable compatible with
Cisco, SCR+ & - should
be tristated when in
DTE mode, double
term, double buffer)
6
Out
SCR-
13
Out
23
SCT+
Out
SCTShorting GR 1
Out
47, 48
41
42
CHAPTER 2: INSTALLATION
Table 18 X.21 DCE Cable Pinouts (60-pin Male to 15-pin Female; Part # 3C63925)
Signal Name
Pin # on
60 PIN CONN
Direction
Pin # on DB15 CONN (For QSIM)
Frame GND
46
1
Circuit GND
15
8
RTS
9, 10
3, 10
Out
CTS
1, 2
5, 12
In
DSR
In
DCD (not used, see
DCE cable note)
In
DTR
Out
LL (not used)
Out
SD+
11
2
Out
SD-
12
9
Out
RD+
28
4
In
RD-
27
11
In
SCTE+
Out
SCTE-
Out
SCR+
26, 24
6
In
SCR-
25, 23
13
In
SCT+
In
SCT-
In
Shorting GR 1
47, 48
Shorting GR 2
51, 52
Step 4: Connect I/O Cabling and Wiring
43
Once you have connected the QSIM, verify the front panel indicators. As shown in
Figure 18, in addition to the common system front panel indicators, each port has
a pair of LEDs to the left of the port.
ENBL—Illuminates when the port is in service.
CLK—Illuminates when clocking is in service.
Figure 18 QSIM LEDs
Slot 1
Slot 18
Power On
Inservice
Fail
Test
CLK
ENBL
PORT 4
PORT 3
60-Pin
Amphenol
Connectors
PathBuilder
S700
PORT 2
PORT 1
44
CHAPTER 2: INSTALLATION
Connecting a HSIM
Module
Connect a HSIM module using a HSSI SCSI-II 50-pin cable, as shown in Figure 19.
Figure 19 HSIM Connection
Slot 1
Slot 18
HSSI
Router
PathBuilder
S700
Step 4: Connect I/O Cabling and Wiring
45
Once you have connected the HSIM module, verify the front panel indicators. As
shown in Figure 19, the HSIM module has two front panel indicators in addition to
the common system LEDs:
Inservice—Indicates that the HSIM card is active.
Not Used—Indicates that the HSIM card is not in use.
Figure 20 HSIM LEDs
Slot 1
Slot 18
Power On
Inservice
Fail
Test
Not
Used
Inservice
Enable
RX CLK
PathBuilder
S700
RX DATA
TX CLK
TX DATA
46
CHAPTER 2: INSTALLATION
Connecting a DS1 Frame
Access Module
Connect a DS1 Frame Access Module (FAM) using up to eight RJ48 interfaces for
T1 traffic, as shown in Figure 21.
The PathBuilder S700 supports two models of DS1 FAM modules:
front-connecting modules, which you connect from the front of the unit, as
described in this section, and rear redundant modules, which you connect from
the rear of the unit. For details about how to connect rear redundant DS1 FAM
modules, see “Connecting Rear Redundant Modules” later in this chapter.
Figure 21 FAM Connection
Router
n x 64K
Frame Relay
PathBuilder
S700
Step 4: Connect I/O Cabling and Wiring
47
Once you have connected the FAM, verify the front panel indicator sequence
illustrated in Figure 22.
Figure 22 FAM LEDs
Power
Inservice
Fail
Test
Active
Not
Used
PathBuilder
Inservice
S700
The FAM features eight pairs of port indicator LEDs in addition to the common
system front panel indicators—each pair corresponds to one of the eight ports on
the FAM.
Inservice—Indicates that the FAM card is active.
Not Used—Indicates that the FAM card is not in use.
Verifying CPU LEDs and
Connecting the Office
Alarm Connector
In addition to the common front panel indicators, the Management CPU module
features the following LEDs:
Critical—Indicates a critical alarm.
Major—Indicates a major alarm.
Minor—Indicates a minor alarm.
ACO—Alarm Cut off; illuminates when you push the ACO button. The ACO is
used in conjunction with an external audible alarm. Pushing the ACO button cuts
off the audible alarm and illuminates the ACO LED.
48
CHAPTER 2: INSTALLATION
You must verify the front panel indicator sequence illustrated in Figure 23.
Figure 23 Management CPU LEDs and ACO Button
1.
2.
Power
Inservice
Common
System
Fail
Slot 1
Slot 18
Test
Active
Critical
CPU
LEDs
Major
Minor
ACO
Power
Up
ACO
Button
Power On
Tests
Completed
PathBuilder
S700
The PathBuilder S700 supports both an audible and a visual alarm, but the ACO
extinguishes only the audible alarm.
Connecting the Office Alarms
As shown in Figure 24, the PathBuilder S700 features three alarm connectors on
the rear of the unit:
n
External alarm—Connect up to three external alarms from outside
equipment.
n
Visual alarm—Connect a visual alarm that will illuminate whenever a critical,
major, or minor alarm occurs on the shelf. To extinguish the visual alarm, you
must clear the alarm.
n
Audible alarm—Connect an audible alarm that will ring whenever a critical,
major, or minor alarm occurs on the shelf. To extinguish the audible alarm,
clear the alarm or press the ACO button on the front of the MCPU module.
Step 4: Connect I/O Cabling and Wiring
49
Figure 24 PathBuilder S700 Alarm Connectors
Audible Alarm
Visual Alarm
External Alarm
TX RX
TX RX
TX RX
TX RX
Connecting the External Alarm Table 19 lists the pinouts for the external
alarm connector. You can connect up to three alarms from outside equipment
using the specified pairs of pins (pins 5 and 9 for alarm #1, pins 8 and 3 for alarm
#2, and pins 2 and 6 for alarm #3). Set the state of these alarms to Normally Open
or Normally Closed from the Shelf Configuration menu. See “Setting External
Alarm Status” in Chapter 5 for details.
Table 19 External Alarm Connector Pinouts
PIN 5
External Alarm #1
PIN 9
External Alarm #1 Return
PIN 8
External Alarm #2
PIN 3
External Alarm #2 Return
PIN 2
External Alarm #3
PIN 6
External Alarm #3 Return
PINS 1, 4, 7
No Connect
50
CHAPTER 2: INSTALLATION
Connecting the Visual Alarm Table 20 lists the pinouts for the visual alarm
connector. Connect your alarm equipment to the appropriate pins, as determined
by the type of alarm equipment you are using. For example, if the alarm
equipment you are using requires an Open state when there is no alarm, connect
to pins 1 and 2 for the minor alarm, 7 and 8 for the major alarm, and 4 and 5 for
the critical alarm. When the MCPU detects a minor, major, or critical alarm, the
appropriate LED illuminates. To turn off the LED, you must clear the alarm.
Table 20 Visual Alarm Connector Pinouts
PIN 1
Minor Alarm Return (Common)
PIN 6
Minor Alarm Normally Closed (NC)
PIN 2
Minor Alarm Normally Open (NO)
PIN 7
Major Alarm Return (Common)
PIN 3
Major Alarm Normally Closed (NC)
PIN 8
Major Alarm Normally Open (NO)
PIN 4
Critical Alarm Return (Common)
PIN 9
Critical Alarm Normally Closed (NC)
PIN 5
Critical Alarm Normally Open (NO)
Connecting the Audible Alarm Table 21 lists the pinouts for the audible alarm
connector. Connect your alarm equipment to the appropriate pins, as determined
by the type of alarm equipment you are using. For example, if the alarm
equipment you are using requires an Open state when there is no alarm, connect
to pins 1 and 2 for the minor alarm, 7 and 8 for the major alarm, and 4 and 5 for
the critical alarm. When the MCPU detects a minor, major, or critical alarm, the
alarm rings. To turn off the alarm, press the ACO button on the front of the MCPU
module.
Table 21 Audible Alarm Connector Pinouts
PIN 1
Minor Alarm Return (Common)
PIN 6
Minor Alarm Normally Closed (NC)
PIN 2
Minor Alarm Normally Open (NO)
PIN 7
Major Alarm Return (Common)
PIN 3
Major Alarm Normally Closed (NC)
PIN 8
Major Alarm Normally Open (NO)
PIN 4
Critical Alarm Return (Common)
PIN 9
Critical Alarm Normally Closed (NC)
PIN 5
Critical Alarm Normally Open (NO)
Step 4: Connect I/O Cabling and Wiring
Verifying STX LEDs and
Connecting the Optional
BITS Clock
51
The STX module requires no external connections, but you must verify the front
panel indicator sequence illustrated in Figure 25.
Figure 25 STX Module LED Power-up Sequence
1.
2.
3.
4.
Power
Inservice
Fail
Test
Active
PathBuilder
S700
Connecting the Optional BITS Clock (STX)
The PathBuilder S700 can receive or transmit a Bipolar Timing Source (BITS) clock
through the STX module. It offers the following options for the clock setting:
n
T1 CSU
n
DSX 0-133 feet
n
DSX 133-266 feet
n
DSX 266-399 feet
n
DSX 399-533 feet
n
DSX 533-655 feet
If desired, you can connect a BITS clock to the clock signal input or output port
located on the rear of the PathBuilder S700 using a DB-9 connector, as shown in
Figure 26.
This feature is currently available for North American, DSI, Standard carrier signals.
52
CHAPTER 2: INSTALLATION
Figure 26 BITS Clock Connection (STX Module)
BITS Out
BITS In
TX RX
TX RX
TX RX
TX RX
Table 22 and Table 23 list the connector pinouts for the input and output
connectors.
Table 22 STX Module BITS Clock Input Connector Pinouts
PIN 1
Receive Tip
PIN 2
Receive Ring
PIN 3
NC
PIN 4
NC
PIN 5
NC
PIN 6
NC
PIN 7
NC
PIN 8
NC
PIN 9
NC
Table 23 STX Module BITS Clock Output Connector Pinouts
PIN 1
NC
PIN 2
NC
PIN 3
NC
PIN 4
Transmit Tip
PIN 5
Transmit Ring
PIN 6
NC
PIN 7
NC
PIN 8
NC
PIN 9
NC
Step 4: Connect I/O Cabling and Wiring
53
To enable the BITS clock, you must make the following jumper settings on the STX
module:
JP9 (1-5)
JP9 (2-6)
JP9 (3-9)
JP9 (4-10)
For information about how to select the BITS clock as the source for system
timing, see “Managing the System Clock” in Chapter 5.
Connecting Rear
Redundant Modules
The following PathBuilder S700 modules are available in either front-connecting or
rear redundant models:
n
DS3/E3 UNI
n
DS1/E1 UNI with Inverse Multiplexing for ATM (IMA)
n
DSX-1/E1 CBR
Figure 27 illustrates the locations of the connectors on the rear of the unit.
Figure 27 PathBuilder S700 Rear Connectors
Slot 18
Port 2
DS3/E3
Port 1
DS3/E3
Slot 5
TX
RX
TX
RX
Slots 1-4
TX RX
TX RX
TX RX
TX RX
10BaseT
SLIP
RS-232
Slots 16-18
Slots 13-15
Slots 10-12
Slots 7-9
Reserved
for later use
When connecting rear redundant modules, follow these guidelines:
n
Connect DS3 UNI or E3 UNI modules to DS3 or E3 repeaters using the pair of
BNC connectors corresponding to the slot(s) in which you have the DS3/E3 UNI
module(s) installed. For example, if you had a DS3 UNI module installed in slot
7, you would use the connectors in the third column from the right. For this
release, use only the bottom two rows of connectors; the top two rows are
reserved for future expansion.
n
Connect DS1/E1 UNI or DSX-1/E1 CBR modules to the pair of Telco connectors
corresponding to the slot(s) in which the module(s) are installed.
54
CHAPTER 2: INSTALLATION
Table 24 lists the connector pinouts for the Telco connectors. Note the following as
you use this table:
n
The notations A, B, and C indicate the slot.
n
A corresponds to the slot with the lowest number
n
B corresponds to the slot with the middle number
n
C corresponds to the slot with the highest number
For example, for the slot 7-9 connector, A corresponds to slot 7, B corresponds
to slot 8, and C corresponds to slot 9.
n
The pinouts are the same for both the Tx (out) and the Rx (in) connectors.
Table 24 Telco (T1/E1) Connector Pinouts
PIN 25
NC
PIN 50
NC
PIN 24
ATIP1
PIN 49
ARING1
PIN 23
ATIP2
PIN 48
ARING2
PIN 22
ATIP3
PIN 47
ARING3
PIN 21
ATIP4
PIN 46
ARING4
PIN 20
ATIP5
PIN 45
ARING5
PIN 19
ATIP6
PIN 44
ARING6
PIN 18
ATIP7
PIN 43
ARING7
PIN 17
ATIP8
PIN 42
ARING8
PIN 16
BTIP1
PIN 41
BRING1
PIN 15
BTIP2
PIN 40
BRING2
PIN 14
BTIP3
PIN 39
BRING3
PIN 13
BTIP4
PIN 38
BRING4
PIN 12
BTIP5
PIN 37
BRING5
PIN 11
BTIP6
PIN 36
BRING6
PIN 10
BTIP7
PIN 35
BRING7
PIN 9
BTIP8
PIN 34
BRING8
PIN 8
CTIP1
PIN 33
CRING1
PIN 7
CTIP2
PIN 32
CRING2
PIN 6
CTIP3
PIN 31
CRING3
PIN 5
CTIP4
PIN 30
CRING4
PIN 4
CTIP5
PIN 29
CRING5
PIN 3
CTIP6
PIN 28
CRING6
PIN 2
CTIP7
PIN 27
CRING7
PIN 1
CTIP8
PIN 26
CRING8
Step 5: Connect a Management Terminal
Step 5: Connect a
Management Terminal
55
In order to configure application connections and an IP address for SNMP support,
you must connect a management terminal to the PathBuilder S700. To do this, you
use the 10Base T, RS-232, and SLIP ports on the rear of the PathBuilder S700.
To connect a network management terminal, follow these steps:
1 Connect a VT 100 terminal to the RS-232 (console) port.
2 Use the VT100 terminal to input an IP address for the PathBuilder S700. See
“Setting up Communication Parameters” in Chapter 3, for details.
3 Establish communication between the PathBuilder S700 and any management
terminal in one of these ways:
n
Direct RS-232 using the VT100 terminal or VT100 emulator, as described above
n
Direct 10BaseT using an IP Telnet session
n
SLIP or PPP over a dialup network using an IP Telnet session
Figure 28 illustrates the network management station terminal connection
options.
Figure 28 NMS Terminal Connection Options
NMS Terminal
(PC or Workstation
in TELNET Session)
TX RX
TX RX
TX RX
TX RX
LAN
DTE
Straight Through
RS 232 Cable
DCE
Modem
(9600 Baud)
RS 232 Null
Modem or
Crossover
Cable (50
Feet or Less)
Dialup
Network
SLIP or
PPP
DTE
Modem
(9600 Baud)
RJ 45
Pin Signal Pin
1
2
3
4
TX+
TXRX+
NC
5
6
7
8
Female DB9
Signal
NC
RXNC
NC
Pin
1
2
3
4
Signal
Frame Gnd
RX Data
TX Data
DTR
Pin
Signal
5
6
7
8&9
Signal Gnd
DSR
RTS
NC
NMS Terminal
(UNIX PC in
TELNET Session)
DTE
Local Terminal
(VT100)
56
CHAPTER 2: INSTALLATION
After you have connected the network management terminal, perform initial
configuration of the unit, as described in Chapter 3.
GETTING STARTED
3
This chapter tells you how to log on to the PathBuilder S700 WAN access switch
(PathBuilder S700), how to use the PathBuilder S700 menus, and how to perform
initial configuration using the NMS menus. It contains the following sections:
Logging On
n
Logging On
n
Using the Menus
n
Performing Initial Configuration
You enter initial configuration information via the local VT100 user interface.
Figure 29 illustrates the terminal connection options.
Figure 29 NMS Terminal Connection Options
NMS Terminal
(PC or Workstation
in TELNET Session)
TX RX
TX RX
TX RX
TX RX
LAN
DTE
Straight Through
RS 232 Cable
DCE
Modem
(9600 Baud)
RS 232 Null
Modem or
Crossover
Cable (50
Feet or Less)
Dialup
Network
SLIP o
PPP
DTE
Modem
(9600 Baud
RJ 45
Pin Signal Pin
1
2
3
4
TX+
TXRX+
NC
5
6
7
8
Female DB9
Signal
NC
RXNC
NC
Pin
1
2
3
4
Signal
Frame Gnd
RX Data
TX Data
DTR
Pin
Signal
5
6
7
8&9
Signal Gnd
DSR
RTS
NC
NMS Terminal
(UNIX PC in
TELNET Session)
DTE
Local Terminal
(VT100)
58
CHAPTER 3: GETTING STARTED
The user interface is preserved on a VT100 terminal connected to the RS-232
(console) port on the Management CPU in slot 1 of the PathBuilder S700. Set the
terminal for the following:
n
9600 baud
n
no parity
n
8 data bits
n
1 stop bit
When the PathBuilder S700 is powered up and operating, and your terminal is
connected, operating, and properly configured, the Text User Interface (TUI) title
screen shown in Figure 30 appears on your terminal.
Figure 30 PathBuilder S700 Text User Interface Title Screen
The TUI Title screen identifies the interface and its software release number and
prompts you for a password. Enter the default password:
password
If the software does not accept your password entry, try again. If the password still
not accepted, check with your system administrator to obtain the correct
password.
The Main menu, shown in Figure 31, appears.
Using the Menus
59
Figure 31 PathBuilder S700 Main Menu
Use the options on the Main menu as follows:
Using the Menus
n
Select [1] System Administration to access common parameters.
n
Select [2] Configuration Management to view or set configuration parameters.
n
Select [3] Fault Management to view or acknowledge alarms and set
loopbacks.
n
Select [4] Performance Management to view statistical data.
n
Select [5] Exit to log out.
The title of the menu or display appears at the top of the screen. Your access
status appears in the upper righthand corner.
n
Read-Write means that you have Read-Write control of the PathBuilder S700
and can make changes to the system.
n
Read Only means that you can only monitor the menus and displays.
If you have superuser privileges, you can switch from a Read-Only to a Read-Write
session without logging off. See later in this chapter for details.
Navigating through the
Menus
You select a menu option by typing the selection number and pressing [Enter].
Displays that contain information and no selections include the prompt:
Press Esc for previous menu
Multi-page displays also prompt you to press “N” for the next page or “P” for the
previous page.
Only the Main menu contains the Exit selection to log out. Selecting Exit returns
you to the title screen with the password prompt. All other menus have a Previous
Menu selection which returns you to the Main menu one screen at a time. You can
also press [Esc] to move back one menu at a time.
60
CHAPTER 3: GETTING STARTED
The auto logout feature automatically logs you out and returns you to the title
screen if you do not press a key for a specified time (1 - 99 minutes). To set the
autolog timeout, select [1] System Administration from the Main menu, then
select [1] General System Information, then select [6] Set Auto Logout Time.
Understanding the
Menu Hierarchy
The PathBuilder S700 menu hierarchy includes several layers of menus. Each
submenu has a name that is the same or similar to the name of the option that
displays it. For example, selecting [2] Configuration Management on the Main
Menu displays a submenu titled Configuration Management, and selecting
[4] Manage System Clock from the System Administration menu displays a
submenu titled System Clock Configuration.
You can then select options on the submenus to display additional submenus or
prompts that allow you to set various parameters. The options that appear on
some submenus vary, depending on what modules you have installed. For
example, the System Clock Configuration menu includes a Set CBR option only if
you have installed a CBR module, a Set DS3 option only if you have installed a DS3
UNI module, a Set IMA option only if you have installed a DS1 UNI or E1 UNI
module, and so on.
Using the Menus to
Change Settings
Settings are displayed in prompts at the bottom of the menus. For example, if you
select:
[2] Configuration Management
[1] Manage Card
[5] DS3 UNI (may be different choice number, depending upon your shelf
configuration)
[1] Card Information
[5] Set ATM Payload Scramble
The following prompt appears at the bottom of the DS3 UNI Configuration menu:
Enter ATM Payload Scramble (1=No,2=Yes):
When you type a selection number and press [Enter], payload scrambling is
disabled or enabled, and the prompt is cleared.
Alarm Indicator
If the PathBuilder S700 detects an alarm condition, an alarm indicator (the
highlighted word “Alarm”) appears to the left of the access status on every menu
and display, as shown in Figure 32.
Performing Initial Configuration
61
Figure 32 Alarm Indicator
Select to display
menu from which
you can access
screen listing
current alarms
Indicates that an
alarm has been
detected
After you acknowledge the alarm, the alarm indicator is no longer highlighted, but
the word “Alarm” remains in the upper right corner of the screen to indicate that
an alarm has been acknowledged.
When the alarm is acknowledged and the condition that caused the alarm is
cleared, the indicator disappears entirely. If a menu indicates that an alarm has
been acknowledged and a new alarm occurs, the Alarm indicator is highlighted
again.
See “Managing System Alarms” in Chapter 6 for instructions on acknowledging
alarms.
Performing Initial
Configuration
After you install the PathBuilder S700 hardware, you must complete the following
three steps in order to complete the initial configuration:
1 Set up communication parameters
2 Configure In-band Management (optional)
3 Set up passwords
4 Set the time and date
You access the menus used to perform these steps from the System
Administration menu, shown in Figure 33. To display the System Administration
menu:
From the Main menu, select [1] System Administration.
62
CHAPTER 3: GETTING STARTED
Figure 33 System Administration Menu
The following subsections provide instructions for performing the three initial
configuration steps. See Chapter 5 for instructions on configuring specific
PathBuilder S700 modules.
Setting up
Communication
Parameters
In order for the PathBuilder S700 to communicate to the Ethernet network, you
must set the correct communication parameters. To do this, select [3] Manage IP
Network Configuration from the System Administration menu to display the
Manage IP Network Configuration menu, shown in Figure 34.
Figure 34 Manage IP Network Configuration Menu
From the Manage IP Network Configuration menu, you configure the following:
n
Local host IP address
n
Trap client
n
Default gateway
The subsections following the figure describe how to set these parameters.
Performing Initial Configuration
63
Once you have entered the IP address and SNMP information for the PathBuilder
S700 on the VT100 terminal, you can continue configuring the device on the local
console, or you can configure the PathBuilder S700 through either the 10BaseT or
the SLIP/PPP dialup port on the Management CPU module using either a Telnet
session or an SNMP manager such as PathBuilder Switch Manager. See Figure 35.
Figure 35 PathBuilder S700 Terminal Access Methods
SNMP
SNMP
PathBuilder S700
ATM
160.160.1.3
160.160.1.5
160.160.1.1
10BaseT
Mgmt
Module
Telnet
160.160.1.6
Dialup
Port
Telnet
RS 232
Direct
160.160.1.2
RS 232
9600 Bps
VT100
Mask 255.255.255.0
SLIP or PPP
SNMP
or
Telnet
160.160.1.4
Configuring the Local Host IP Address
The Local Host IP Address Configuration menu allows you to set parameters for
the management port (Ethernet or SLIP) or the PathBuilder S700.
To enter configure the Ethernet management port, follow these steps:
1 From the Manage IP Network Configuration menu, select [1] Local Host IP
Configuration to display the Local Host IP Configuration menu, shown in
Figure 36.
When you apply a change to the Local Host IP Configuration menu, you might get
logged out if you are using a Telnet session. The default configuration is Baud rate:
9600, Parity; none, Data Bits:8, StopBits:1.
64
CHAPTER 3: GETTING STARTED
Figure 36 Local Host IP Configuration Menu
2 Select [1] Ethernet Port IP Configuration to display the Ethernet Port IP
Configuration menu, shown in Figure 37.
Figure 37 Ethernet Port IP Configuration Menu
3 Enter the following information (by selecting the appropriate options and
responding to the prompts that appear at the bottom of the screen) to enable IP
Ethernet connections:
IP Address—Provided by the network administrator. This is the IP address of the
PathBuilder S700 Management CPU.
You should consult the network administrator to obtain an IP address for the
PathBuilder S700 which will allow its 10BaseT Management port to co-exist with
hosts on its local LAN.
Subnet Mask—Provided by the network administrator. The subnet mask
identifies the subnetwork containing the PathBuilder S700 Ethernet management
port.
Performing Initial Configuration
65
Community Name—Enter “3Com” (The community name applies to Ethernet
port IP configuration only.)
Figure 38 shows a sample PathBuilder S700 IP host setup.
Figure 38 Sample PathBuilder S700 IP Host Setup
PathBuilder
S700
PathBuilder
S700
192.73.30.99
192.73.30.100
3Com
Community
4 Select [4] Previous Menu to return to the Local Host IP Configuration menu.
5 Select [3] Apply IP Configuration Changes to activate the IP address. The following
prompt appears:
This action will terminate all running TELNET/SNMP sessions.
Are you sure you want to apply IP configuration changes (Y/N)[N]?
6 Enter y to apply your changes.
To enter configure the SLIP management port, follow these steps:
1 From the Manage IP Network Configuration menu, select [1] Local Host IP
Configuration to display the Local Host IP Configuration menu, shown earlier in
Figure 36.
When you apply a change to this menu, you might get logged out if you are using
a Telnet session. The default configuration is: Baud Rate, 9600; Parity, none; Data
Bits, 8, and Stop Bits, 1.
2 Select [2] SLIP Port IP Configuration to display the SLIP Port IP Configuration menu,
shown in Figure 39.
66
CHAPTER 3: GETTING STARTED
Figure 39 SLIP Port IP Configuration Menu
3 Enter the following information (by selecting the appropriate options and
responding to the prompts that appear at the bottom of the screen) to enable IP
Ethernet connectors:
IP Address—Provided by the network administrator. This is the IP address of the
PathBuilder S700 Management CPU.
You should consult the network administrator to obtain an IP address for the
PathBuilder S700 which will allow its 10BaseT Management port to co-exist with
hosts on its local LAN.
Subnet Mask—Provided by the network administrator. The subnet mask
identifies the subnetwork containing the PathBuilder S700 SLIP management port.
4 Select [3] Previous Menu to return to the Local Host IP Configuration menu.
5 Select [3] Apply IP Configuration Changes to activate the IP address. The following
prompt appears:
This action will terminate all running TELNET/SNMP sessions.
Are you sure you want to apply IP configuration changes (Y/N)[N]?
6 Enter y to apply your changes.
Configuring Trap Clients
The PathBuilder S700 can report SNMP trap alarms to a remote management
system. Trap clients are the network management stations to which you want the
PathBuilder S700 to send traps. You can specify up to four trap clients. To
configure trap clients, follow these steps:
1 From the Manage IP Network Configuration menu, select [2] Trap Client
Configuration to display the Trap Client Configuration menu, shown in Figure 40.
Performing Initial Configuration
67
Figure 40 Trap Client Configuration Menu
2 Select the number corresponding to the trap client you want to configure.
Figure 41 shows the menu for configuring trap client 1.
Figure 41 Trap Client 1 Configuration Menu
3 Enter the following information (by selecting the appropriate options and
responding to the prompts that appear at the bottom of the screen) to configure
the trap client:
IP Address—The IP address of the network management station to which you
want the PathBuilder S700 to send traps.
Subnet Mask—The subnet mask for the network management station to which
you want the PathBuilder S700 to send traps.
Port Number—The system-defined port number. You should not modify this
number.
4 Select [4] Previous Menu to return to the Trap Client Configuration menu.
5 Select [5] Previous Menu to return to the Manage IP Network Configuration menu.
68
CHAPTER 3: GETTING STARTED
Configuring the Default Gateway
The default gateway routes IP data to non-local networks (Telnet sessions from
different subnetworks). To configure the default gateway, follow these steps:
1 From the Manage IP Network Configuration menu, select [3] Default Gateway
Configuration to display the Default Gateway Configuration menu, shown in
Figure 42.
2 Enter the following information (by selecting the appropriate options and
responding to the prompts that appear at the bottom of the screen) to configure
the default gateway:
IP Address—The IP address of the router which you want to configure as the
default gateway.
Subnet Mask—The subnet mask for the router which you want to configure as
the default gateway.
Figure 42 Default Gateway Configuration Menu
3 Select [3] Previous Menu to return to the Manage IP Network Configuration menu.
4 Select [4] Previous Menu to return to the System Administration menu.
Configuring In-band
Management
In addition to managing the PathBuilder S700 out-of-band, you can also manage
the unit in-band in one of the following ways:
n
via the 10Base-T port on the near-end MCPU card (up to ten VCs maximum)
n
via the near-end Dual Ethernet module
For detailed instructions on configuring PVCs, see “Configuring Virtual Circuits” in
Chapter 5.
In-band Management via the 10Base-T Port on the Near-end MCPU Card
You can use in-band management to manage any remote PathBuilder unit: S310,
S330, S600, or S700.
Performing Initial Configuration
69
To configure in-band management via the 10Base-T port on the near-end MCPU
card, follow these steps:
If you use this method, you must use a new subnet with each PathBuilder S700
and a new static route for each new subnet on the management station or router.
You are also limited to managing up to ten remote units from the central
management unit.
1 Build a PVC on the near-end PathBuilder S700 from the MCPU to the OC3 UNI,
setting the following parameters on the Add Virtual Circuit screen:
traffic shaper—Choose any of the available values (for example, 10Mbps).
IP address—This address must be different than the local host IP address.
subnet mask—Specify any acceptable address (for example, 255.255.255.0).
VPI/VCI—Enter any values in the accepted range (for example, 10/100).
2 Build a PVC on the far-end PathBuilder unit (S310, S330, S600, or S700) from the
MCPU to the OC3 UNI, setting the following parameters on the Add Virtual Circuit
screen:
traffic shaper—Choose any of the available values (for example 17M).
IP address—You must use a different subnet than the one you used for the
near-end PathBuilder S700.
subnet mask—Specify any acceptable address (for example, 255.255.255.0).
VPI/VCI—You must use the same values as you did for the near-end PathBuilder
S700.
3 From the System Administration menu, set the default gateway for the far-end
PathBuilder unit (S310, S330, S600, or S700) and the management station.
a Set the default gateway on the far-end PathBuilder unit to the PVC IP address
you set for the near-end PathBuilder S700 in step 1.
b Set the default gateway on the management station to the local host IP address
of the near-end PathBuilder S700.
For details about setting the default gateway, see “Configuring the Default
Gateway” earlier in this chapter.
4 Apply your IP configuration changes.
a From the main menu, select [1] System Administration.
b From the System Administration menu, select [3] Manage IP Network
Configuration.
c From the Manage IP Network Configuration menu, select [1] Local Host IP
Configuration.
d From the Local Host IP Configuration menu, select [3] Apply IP Configuration
Changes.
70
CHAPTER 3: GETTING STARTED
In-band Management via the Near-end Dual Ethernet Module
To configure in-band management via the near-end PathBuilder S700 Dual
Ethernet module, follow these steps:
If you use this method, you can manage one PathBuilder S700 in a point-to-point
configuration or as many as 256 remote PathBuilder units (S310s, S330s, S600s,
or S700s) if all the units are connected to an ATM network service provided by a
local or large Telco organization.
1 Build a PVC on the near-end PathBuilder S700 from the Dual Ethernet Module to
the OC3 UNI, setting the following parameters on the Add Virtual Circuit screen:
traffic shaper—Choose any of the available values (for example 17M)
VPI/VCI—Enter any values in the accepted range (for example, 10/101).
2 Attach a hub or Ethernet NIC directly to the Dual Ethernet Module port.
3 Build a PVC on the far-end PathBuilder unit (S310, S330, S600, or S700) from the
MCPU to the OC3 UNI, setting the following parameters on the Add Virtual Circuit
screen:
traffic shaper—Choose any of the available values (for example 17M)
IP address—Specify any acceptable address (for example, 192.198.65.3).
subnet mask—Specify any acceptable address (for example, 255.255.255.0).
VPI/VCI—You must use the same values as you did for the near-end PathBuilder
S700.
4 Apply your IP configuration changes.
a From the main menu, select [1] System Administration.
b From the System Administration menu, select [3] Manage IP Network
Configuration.
c From the Manage IP Network Configuration menu, select [1] Local Host IP
Configuration.
d From the Local Host IP Configuration menu, select [3] Apply IP Configuration
Changes.
Performing Super User
Functions
The PathBuilder S700 supports a total of up to 10 logins at the following three
access levels:
Read-Only User—Can view information and configuration settings in the
PathBuilder S700 interface, but cannot set parameters or make any changes.
Read-Write User—Can view and set/change configuration information.
Super User—Can view and set/change configuration information and can
perform the following super user functions:
n
Set passwords
n
Take over a read-write session
n
Erase the system database
The following subsections provide step-by-step instructions for performing these
super user functions.
Performing Initial Configuration
71
Setting Passwords
The default password for all three access levels is password. This password logs
you on initially as a super user. For security reasons, you should change the Super
User, Read-Write, and Read-Only passwords as soon as possible.
To set the Super User, Read-Write, or Read-Only password, follow these steps:
1 From the System Administration menu, select [13] Super User Privilege to open the
Super User Privilege menu, shown in Figure 43.
Figure 43 Super User Privilege Menu
2 Select [1] Set System Login Password to open the System Login Password menu,
shown in Figure 44.
Figure 44 System Login Password Menu
3 Select [1] Set Super User Password, [2] Set Read-Write Password, or [3] Set
Read-Only Password to set the desired password.
72
CHAPTER 3: GETTING STARTED
The following prompt appears at the bottom of the screen:
Enter New Password:
4 Enter the new password. The password appears as asterisks on the screen as you
enter it.
CAUTION: Be sure to record your new password and keep the record in a safe
place. If you forget your password and have no record of it, you can contact 3Com
for assistance, but we may need to delete your database in order to solve the
problem.
The following prompt appears:
Re-enter New Password:
5 Re-enter the password you entered in step 4.
A message appears, indicating that the password has been saved.
6 Select [4] Previous Menu to return to the Super User Privilege menu.
Taking over a Read-Write Session
The PathBuilder S700 allows only one read-write session at a time. If you have
super user privileges, however, you can take over a read-write session without
logging off. When you take over a read-write session, the previous read-write
session is forced to a read-only session.
To take over a read-write session, follow these steps:
1 From the Super User Privilege menu, shown earlier in Figure 43 select [2] Take
Over Read-Write Session.
The following prompt appears:
Do you want to take over read-write session (Y/N) [N]?
2 Enter y to take over the read-write session.
The following message appears:
The current session has been changed to Read-Write!
Press any key to return.
3 Press any key to resume your session in read-write mode.
Erasing the System Database
In certain situations—if anomalous behavior on the part of the S700 makes you
suspect that the database has been corrupted, or if you have moved a unit from a
different location, for example—you may want to consider erasing the system
database and starting from scratch. You must have super user privileges in order
to erase the system database.
To erase the system database, follow these steps:
CAUTION: Before you erase the system database, make a record of all
configuration settings; these settings will be lost when you erase the database.
Also keep in mind that erasing the database is an action that cannot be undone.
Perform the following procedure only if you are sure that erasing the database is
your best course of action.
Performing Initial Configuration
73
1 From the Super User Privilege menu, shown earlier in Figure 43, select [3] Erase
System Database to open the Erase System Database menu. This menu displays
the following warning and prompt:
This action will cause a SOFT RESET of the system.
Do you want to erase the system database (Y/N) [N]?
2 Enter y to erase the system database.
Setting the Time and
Date
By setting the correct time and date, you ensure accurate alarm reporting by the
NMS software. To set the time and date, follow these steps:
1 From the System Administration menu, select [2] Manage Time and Date to
display the Time and Date Configuration menu, shown in Figure 45.
Figure 45 Time and Date Configuration Menu
The current date and time are displayed above the menu options.
2 Select [1] Set Date. The following prompt appears at the bottom of the screen:
Enter Date (mm/dd/yy)
3 Enter the date.
4 Select [2] Set Time. The following prompt appears at the bottom of the screen:
Enter Time (hh:mm:ss):
5 Enter the time.
Type a time a few seconds in advance of the current time, then press [Enter] when
the current time matches the time you typed.
6 Select [3] Previous Menu to return to the System Administration menu.
7 Select [12] Previous Menu to return to the Main menu.
74
CHAPTER 3: GETTING STARTED
PATHBUILDER S700 MODULE AND
APPLICATION OVERVIEW
4
This chapter provides a brief overview of ATM (Asynchronous Transfer Mode)
technology, describes the features and operation of each of the PathBuilder S700
WAN access switch (PathBuilder S700) modules, and discusses applications
supported by the PathBuilder S700. It contains the following sections:
n
ATM Overview
n
System Module Overview
n
ATM Module Overview
n
Application Module Overview
n
Supported Applications
For specifications for the PathBuilder S700 modules, see “Specifications” in
Chapter 1.
ATM Overview
ATM provides the means of simultaneously transferring a wide variety of services
with different protocols and bandwidth requirements such as voice, packet data,
and video between end users or user networks. It does so by segmenting the input
data streams into 53-byte cells, assigning the cells to virtual circuits set up in the
ATM network, multiplexing the cells for transmission according to the bandwidth
requirements of the individual data streams, and reassembling the cells into the
original data streams at the receiving end.
For more detail about how to apply the PathBuilder S700 to provide ATM WAN
access, see “Supported Applications” in Chapter 4.
Virtual Circuits
ATM networks are organized into virtual circuits or logical duplex paths between
two ATM unit ports.
Each transmission direction in a virtual circuit is referred to as a virtual channel.
Virtual channels are then grouped into virtual paths between two ports. The
channels and paths are assigned numbers: VPIs (Virtual Path Indicators) and VCIs
(Virtual Channel Indicators). Figure 46 illustrates this scheme.
76
CHAPTER 4: PATHBUILDER S700 MODULE AND APPLICATION OVERVIEW
Figure 46 Virtual Circuit Scheme
Transmission
Path
Virtual
Circuit
{
VPI 1
VCI 1 (Transmit)
VCI 1 (Receive)
VPI 2
VCIs
{
VPI 3
VCIs
{
Each ATM cell (a fixed-length unit of data over ATM) is assigned to a virtual circuit
by including the circuit's VPI/VCI in the cell's header. This is then used to steer the
cell through an ATM unit and the ATM network.
Figure 47 illustrates virtual circuits on a simple network using PathBuilder S700s.
Figure 47 Virtual Circuits in a Simple Network
Workstation 1
LAN
AA
S4P1
VPI/VCI 1/33
DS3 UNI
PathBuilder
S700 B
PathBuilder S700 A
S5P1
LAN
AB
S4P2
LAN
BA
S5P2
VPI/VCI
2/35
PathBuilder S700
A
LAN
BB
Workstation 2
Suppose workstation 1 on LAN AA wants to send data to workstation 2 on LAN
BB. It transmits Ethernet packets which include its MAC address and that of
workstation 2. PathBuilder S700 A groups the packets into cells and, since it does
not know where workstation 2 is, broadcasts the cells on all VPI/VCIs.
PathBuilder S700 B learns that workstation 1 transmits to its slot 4 port 2 over
VPI/VCI 1/33 and to slot 5 port 2 over VPI/VCI 2/35. This information is then stored
in forwarding tables in PathBuilder S700 B.
When workstation 2 responds, it includes its MAC address and that of workstation
1 in the packets. PathBuilder S700 B looks in the appropriate forwarding table and
finds that it can reach workstation 1 on VPI/VCI 2/35. When the first response cell
on 2/35 is formatted back into packets at PathBuilder S700 A, PathBuilder S700 B
learns how to reach workstation 2 without broadcasting.
System Module Overview
System Module
Overview
Management CPU
Module
77
The PathBuilder S700 includes the following two system modules:
n
Management Central Processing Unit (MCPU) module
n
STX Module
The MCPU module, located in slot 1 of the PathBuilder S700 shelf, performs all
configuration, monitoring and user interface functions. It features the following:
n
Management processor
n
Two RS-232 interfaces (one for terminal interface and one for SLIP/PPP
interface)
n
Ethernet port (for management of the PathBuilder S700 via the network)
n
CPU memory consisting of a real time clock, dynamic RAM, and dual FLASH.
The dual FLASH is used so that the code can be upgraded and two copies of
the code can be stored at one time. The CPU can run either copy of the code
under user control and the CPU code can be upgraded on-line.
n
Two sets of three relay contacts for critical, major, and minor visual and audible
alarms, located on the rear of the unit. The alarm relays are normally open.
They trigger the audible and visual alarms whenever the CPU determines there
is a critical, major, or minor alarm. You can cut off the audible alarm (open the
relay) by pressing the ACO button.
n
Relay contacts for up to three external alarms from outside equipment for
which the alarm indication is activated when the input pins are shorted. You
can set these alarms to be either normally open or normally closed. For details
about setting the state of the external alarms, see “Configuring the Shelf” in
Chapter 5.
n
A SAR interfacing an ATM bus. The SAR is used for communication and
signaling. It can send and receive packets from the ATM network under CPU
control. The user interface allows you to enter management VCs in the same
way any other VC is entered. Management VCs terminate on the CPU SAR.
n
User interface software that allows you to interface to the system in multiple
ways:
n
n
n
n
Through an RS-232 port for direct VT100 Connection. The CPU contains the
VT100 drivers to control the management and user interface screens.
Through a second RS-232 port to run SLIP/PPP. This port can connect via a
modem to the user management network. You can then run a Telnet
session to access the NMS screens.
Through the direct Ethernet connection. You can then run a Telnet session
to access the NMS screens.
SNMP support via the RS232 SLIP/PPP and the Ethernet connection. The
PathBuilder S700 supports multiple standard MIBs for the bridge, Ethernet,
DS1, DS3, and ATM Forum compliant IMA functions. It also supports an
Enterprise MIB that allows you to configure and monitor the unit using an
SNMP-based Enterprise management system such as 3Com’s Transcend.
The CPU stores all the code that runs on the system and runs diagnostics at
bootup to check the integrity of the system.
78
CHAPTER 4: PATHBUILDER S700 MODULE AND APPLICATION OVERVIEW
SNMP MIB Standards Support
Table 25 lists the standards that are supported for the MIBs.
Table 25 Supported MIBs
STX Module
Document Name
Description
RFC 1213
MIB II
RFC 1406
DS1/E1 MIB
RFC 1407
DS3/E3 MIB
RFC 1493
Bridge MIB (previously RFC 1286)
RFC 1595
SONET MIB
RFC 1643
Ethernet MIB
AF-PHY-0086.000.mib
ATM Forum Compliant IMA MIB
The STX module provides a switching matrix that supports sophisticated traffic
management, priority queuing, and multicasting. It performs all functions
necessary for concentrating and switching ATM cells according to the set priority
given to its Class of Service traffic types:
n
Provides any-to-any switching based on VC address
n
Supports virtual interfaces (VIs)—logical UNI ports
n
n
Slots 5 and 6 support up to 15 VIs each.
For slots 7-18, each bus supports three slots (7-9, 10-12, 13-15, and 16-18),
and the PathBuilder S700 supports up to 24 VIs for each bus. As the VIs are
assigned, the software automatically allocates them among the slots. In
other words, all 24 VIs on a particular bus could be allocated to a single slot.
n
Supports Deep buffers (8,000 cells per VI) for queuing to support 4 Classes of
Services per VI
n
Provides priority queuing in which each VC can be assigned to a specific VI
which then can be allocated to one of 4 queues for CBR, VBR-rt, VBR-nrt, and
UBR classes of service.
n
Supports per VC traffic policing
n
Supports multicasting (up to 256 connections with 32 leaves)
n
Supports per VC statistics
n
Allows a total of 4,000 two-way connections maximum per PathBuilder S700
n
Generates the backplane timing 8KHZ clock and generates ATM bus timing
n
Accepts an 8kHZ signal from all modules together with a 1.544MHz external
BITS Clock
n
Performs all address translation functions
ATM Module Overview
79
Priority Queuing
The PathBuilder S700 with STX provides separate cell buffer queues per virtual
interface. You can assign multiple VCs to each virtual interface and map them to
the desired queue. The STX services the queues in order: queue 0, then queue 1,
then queue 2 and queue 3. Figure 48 illustrates this priority queuing.
In Figure 48, all 24 VIs on a triple-slot bus have been allocated to a single slot. You
can also distribute VIs among the slots supported by a bus. For details, see
“Configuring Virtual Interfaces” in Chapter 5.
Figure 48 PathBuilder S700 with STX Priority Queuing
CBR
VBR
"Virtual
Interfaces"
1
2
3
Physical
Port
Q0 = 500 cell buffer
Q1 = 1500 cell buffer
Traffic
Shaper
Q2 = 3000 cell buffer
Q3 = 3000 cell buffer
24
Cell Bus
Queue Controller
Cell buffers
If the STX finds data in a higher queue while it is servicing another queue, it
services the higher queue, thereby maintaining the priority. For example, if the STX
finds data in queue 0 while it is servicing queue 2, the STX services queue 0. By
queuing the VCs in this way, the STX ensures that the Class of Service is
maintained.
The ensuing traffic from the queues is then shaped according to the traffic
shaping parameter that you set (64Kbps to 155 Mbps) in cells per second. In
addition, each circuit can be policed before reaching its queue. Tagged cells may
be dropped if a queue is found to be congested based on the threshold you have
set. Therefore the combined cell rate of all circuits mapped to a VI can be greater
than the shaper rate of the VI.
ATM Module
Overview
The PathBuilder S700 supports the following application modules with ATM
interfaces:
n
DS3 UNI
n
E3 UNI
n
OC3/STM-1 UNI
n
DS1 UNI with IMA
n
E1 UNI with IMA
80
CHAPTER 4: PATHBUILDER S700 MODULE AND APPLICATION OVERVIEW
DS3 UNI Module
Overview
E3 UNI Module
Overview
The DS3 module is compatible with AT&T Publication 54014 specifications, uses
the unchannelized format, and is compliant to M23 or the C-bit parity ANSI-107a,
1991 specifications. It performs the following key functions:
n
Provides line interface functions and terminates the FEAC and MDL for the
C-bit format
n
Performs ATM to physical layer mapping and adds PLCP according to UNI 3.0
n
Performs peak traffic shaping on the transmit (14 bulk shapers)
The E3 UNI module is typically used for terminating/accessing public or private
WAN services. However, depending on your local applications, you can also use
this module in the port slot for taking local traffic across the WAN.
The E3 UNI module performs the following key functions:
OC3/STM-1 UNI Module
Overview
n
Performs ATM to physical layer mapping and adds PLCP according to UNI 3.0
n
Performs peak traffic shaping on the transmit (14 bulk shapers)
There are two versions of the OC3/STM-1 module: multi-mode fiber and
single-mode fiber. The multi-mode fiber module is typically used for connecting
ATM LAN equipment such as 3Com CoreBuilder 7000. The single-mode fiber
module is typically used for WAN ATM services, providing a longer reach in terms
of distance. Both version support the European SDH framed optical networks
(STM-1).
The OC3/STM-1 UNI module provides an ATM connection at up to 155 Mpbs and,
like other UNI modules, it supports multiple traffic shaper values.
DS1/E1 UNI with IMA
Module Overview
Application Module
Overview
The DS1/E1 UNI module provides Inverse Multiplexing of ATM cell streams over
multiple T1/E1 physical links, based on the industry standard ATM Forum
Specification. It provides the following key benefits:
n
Uses a cell-based multiplexing technique to convert a single ATM stream into
multiple lower speed ATM streams to be sent over independent links and
retrieve the initial ATM cell stream from the links at the far end
n
Preserves cell order from end-to-end in the ATM layer
n
Supports up to 8 DS1/E1 ports (n = 1 to 8)
n
Supports multiple IMA groups
n
Supports differential delay tolerance up to 70ms for DS1 and 56ms for E1
n
Handles link addition/deletion, failure/recovery with minimal disruption
n
Provides ATM Forum specified performance statistics
The PathBuilder S700 supports the following application modules:
n
Ethernet (Dual Ethernet Module)
n
CBR (DSX-1 CBR, E1 CBR)
n
Frame Relay (QSIM, HSIM, FAM)
Application Module Overview
Ethernet Module
Overview
81
The Ethernet module (Dual Ethernet) is a port or application module that takes
legacy LAN traffic across a WAN ATM network using the PathBuilder S700. This
module is used to connect LAN segments and bridge or IP forward traffic across
the ATM network to a LAN/IP service.
The Ethernet module supports two 10BaseT Ethernet connections. It provides a
bridge function together with a SAR conversion to ATM cells. The Ethernet module
performs the following key functions:
n
Provides line interface for two 10BaseT Ethernet connections.
n
Performs bridge function and encapsulation according to RFC1483 with
multicast support.
n
Performs segmentation and assembly to ATM, with 14 programmable traffic
shapers on the transmit (PCR, SCR, MBS settings available).
n
Provides a wire speed forwarding rate of 14700 packets per port.
n
Supports Spanning Tree
Ethernet Module Standards Support
Table 26 lists the standards currently supported by the Ethernet module.
Table 26 Supported Ethernet RFC Standards
RFC Number
Description
RFC 826
ARP
RFC 1042
Standard for the Transmission of IP Datagrams over IEEE.802 Networks
RFC 1483
Multiprotocol Encapsulation Over ATM Adaptation Layer
RFC 1577
Operation for ATM ARP and In ARP LLC/SNAP Encapsulation of IP, etc.
Ethernet Module Operation
The Ethernet module contains a high-performance CPU that performs all the
bridging and packet switching functions. The Ethernet CPU communicates to the
management CPU. Specific module information (serial number, type, MAC
address etc.) is stored and accessed through the management CPU. After bootup,
the local CPU requests actual run code from the management CPU. Figure 49
shows a functional block diagram for the Ethernet module.
The data flow in the Ethernet module is as follows:
n
Packets appearing on the 10BaseT ports from the LAN are checked for packet
integrity and stored in the shared memory area. Up to a Megabyte of memory
is reserved for data.
n
The CPU examines the packet's header in memory and a bridge operation is
performed to determine if the packet goes on the WAN. See “Bridging”, later
in this chapter, for details about the bridge operation.
n
If the packet is to go on the WAN, the bridge determines the VCC connection
for the packet destination.
n
The packet is then encapsulated according to RFC 1483 and the descriptor is
handed off to the SAR together with the associated ATM header descriptor.
n
The SAR append the AAL5 convergence sublayer to the packets and queues
the packets according the shaper you specify for that connection in the user
interface.
82
CHAPTER 4: PATHBUILDER S700 MODULE AND APPLICATION OVERVIEW
Figure 49 PathBuilder S700 Ethernet Block Diagram
PathBuilder
S700
PathBuilder
S700
DS3
PathBuilder
S700
Ethernet
Input
VP.VC
Bridge
Function
DS3
MAC Address to VP.VC Map
VP.VC
02608C123456 = DS3, 0.35
ATM
Network
DS3
PathBuilder
S700
PathBuilder
S700
The data is not moved or copied in memory from the time it is received till the time
it is segmented. This guarantees maximum performance of the system.
DSX-1/E1 CBR Module
Overview
n
On the opposite side, cells are received from the DS3 UNI, or other ATM
module, side through the STX module.
n
The SAR then assembles the cells belonging to the connections specified for it
and the CPU is given confirmation for the cells that are assembled.
n
The bridge function of the CPU examines the packet header, removes the
encapsulations, and forwards the packet to the proper destination after
learning the address and updating the bridge table. For further information on
bridging, see “Bridging” later in this chapter.
The PathBuilder S700 supports two CBR modules: DSX-1 CBR and E1 CBR. These
modules are port or application modules for connecting devices such as PBXs
(Private Branch eXchanges), video codecs, DSU/CSUs, T1 multiplexers, and channel
banks for connection over an ATM WAN service.
DSX-1 CBR Module
The CBR service module provides four or eight DSX-1 ports for transit over an ATM
network. The DSX-1 inputs can be either ESF or SF using B8ZS or AMI. The
received frame can be tunneled through the ATM network using DS1 unstructured
mode or broken up into its DS0 and ABCD signaling components using DS1
structured mode. The structured mode allows DS0 mid span drop and insert or
grooming.
Structured and unstructured modes comply with ATM Forum AF-SAA-0032.000.
This service maps the DS1 service through AAL1 adaptation layer over a CBR
Application Module Overview
83
virtual channel connection (VCC). The VCC is established as a permanent virtual
circuit (PVC) and mapped from the PathBuilder S700s ATM port to either another
PathBuilder WAN access switch or an ATM Forum circuit emulation compliant
device.
The emulated circuit connection from the DSX-1 CBR port to a remote DSX-1 CBR
port is accomplished by mapping DS1 circuits to Permanent Virtual Circuits. These
circuits will then be transmitted through the ATM network to the destination port.
For details on configuring the PVC, see “Configuring Virtual Circuits”” in
Chapter 5.
Cell Delay Variation is compensated for by the PathBuilder S700 through an
adaptive receive buffer. This buffer can provide consistent synchronous delivery of
DS1 service by building in delay in excess of ATM cell delay and outputting from a
receive buffer. You can configure the adaptive delay.
Dynamic Bandwidth Allocation Through dynamic bandwidth allocation, the
DSX-1 CBR module can de-activate the CBR PVC and free up network access
bandwidth for other uses. See “DS0 Signaling and Dynamic Bandwidth
Allocation”, later in this chapter, for details.
DSX-1 CBR Module Standards Support Table 27 lists the ATM standards
supported by the DSX-1 CBR module.
Table 27 DSX-1 CBR Module ATM Forum/ANSI/ITU-T Supported Standards
Standard
Description
AF-SAA-0032.000
ATM Forum Circuit Emulation Service (CES)
ANSI T1.630/ITU-T I.363
AAL1 Unstructured Data Transfer Mode
E1 CBR Module
The E1 CBR module features four or eight E1 ports for transit over an ATM
network. It provides a circuit emulator service mapped to ATM cells. The E1 inputs
can be either single or multi-frame using HDB3 line coding. The received frame
can be tunneled through the ATM network using E1 unstructured mode or broken
up into its DS0 and ABCD signaling components using E1 structured mode. The
structured mode allows DS0 mid span drop and insert or grooming.
The structured and unstructured mode comply with ATM Forum
AF-SAA-0032.000. This service maps the E1 service through AAL1 adaptation
layer over a CBR virtual channel connection (VCC). The VCC is established as a
permanent virtual circuit (PVC) and mapped from the PathBuilder S700s ATM port
to either another PathBuilder S700 or an ATM Forum circuit emulation compliant
device.
Network Cell Delay Variation is compensated for by the PathBuilder S700 through
an adaptive receive buffer. This buffer can provide consistent synchronous delivery
of E1 service by building in delay in excess of ATM cell delay and outputting from a
receive buffer. The adaptive delay is configurable.
84
CHAPTER 4: PATHBUILDER S700 MODULE AND APPLICATION OVERVIEW
E1 CBR Module Standards Support Table 28 lists the standards supported by
the E1 CBR module.
Table 28 E1 CBR Module ATM Forum/ANSI/ITU-T Supported Standards
QSIM/HSIM/FAM
Module Overview
Standard
Description
AF-SAA-0032.000
ATM Forum Circuit Emulation Service (CES)
ANSI T1.630/ITU 1.36
AAL1 Unstructured Data Transfer Mode
The PathBuilder S700 supports three Frame Relay modules: QSIM, HSIM, and FAM.
These modules are port, or application, modules for connecting non-ATM devices
to ATM services. Typical device applications include FRADs (Frame Relay Assembler
and Disassembler or Frame Relay Access Devices), channel extenders, FEPs
(Front-End Processors), and routers.
The HSIM module is used to interconnect terminals to DCE devices that must
operate between 3 and 20Mbps.
Table 29 summarizes the basic features of the three Frame Relay modules.
Table 29 PathBuilder S700 Frame Relay Modules
Module
Acronym
# of ports
Type of ports
Quad Serial Interface
Module
QSIM
4
V.35, RS449, EIA 530, X.21
(64K to 8 Mbps)
HSSI Module
HSIM
1
HSSI (20 Mbps)
Frame Access Module FAM
8
T1 (64K to 1.5 Mbps)
Each of the Frame Relay modules provides a number of serial interfaces and an
ATM SAR and is able to perform cell-to-frame as well as frame-to-cell conversion.
Frames received from the HDLC serial interfaces are segmented in to cells by SAR
and passed to the ATM backplane. In the other direction, cells received from ATM
backplane will be reassembled into frames and passed to the HDLC serial
interfaces.
A RISC processor on the Frame Relay module performs these functions:
n
management CPU (MCPU) communication
n
hardware device configuration
n
frame/cell conversion
n
permanent virtual circuit management
n
alarm generation
n
statistical data collection.
The SAR contains 15 traffic shapers, each of which can be programmed for
sustained cell rate of transmission, peak cell rate, and maximum burst size.
Supported Applications
85
The traffic shapers work as follows:
Supported
Applications
n
The packet is segmented using a dual leaky buffer algorithm, whereby the cells
are transmitted from each connection in the shaper at an average rate until the
bucket of tokens fills up (a token is given to the connection at an average rate
if it has no cells to transmit at that moment).
n
The shaper then turns the burst mode on and transmits at the peak rate for a
burst length. Note that the shaper serves every connection independently.
n
PCR, SCR, and MBS settings are available.
This section describes the following applications supported by the
PathBuilder S700:
n
Virtual circuits
n
Bridging
n
Spanning Tree
n
CBR application
n
Ethernet and voice application
n
Frame application
See the following subsections for details about how the PathBuilder S700
implements these applications.
Bridging
The bridge function is an integral part of the Ethernet module. The PathBuilder
S700 supports ATM permanent virtual circuits (PVCs) for access to the ATM
network. These PVCs connect an PathBuilder S700 Ethernet port through the ATM
network to another PathBuilder S700 Ethernet port. All the PVCs configured for a
port will form a virtual Bridged Ethernet network to all other ports at the other
end of the PVC.
The bridge operation is equivalent to a multiport bridge. The two Ethernet ports
on the module are treated separately unless they are connected through the ATM
network via PVCs. The ATM Layer operates transparently under the datalink layer
to allow higher level protocols to run without changes.
The CPU examines each packet's headers while they are in memory and performs
the bridging operations. A bridge is configured and maintained for each slot and
port in the PathBuilder S700. The bridge maintains the following:
n
A forwarding table in its memory that lists the source and destination addresses
contained in each packet that passes through the PathBuilder S700
n
An aging timer that removes addresses from the forwarding table if an address
is not used for a configured time
n
A configured list of protocols, source addresses, and destination addresses that
will be rejected by the bridge. For information on configuring bridging filters,
see “Configuring the Bridge”” in Chapter 5.
The bridge learns and builds forwarding tables for every PVC that is tied to that
port. When a packet is received on the port or any PVC tied to that port, the
Source MAC address is learned and kept in the forwarding table until the aging
86
CHAPTER 4: PATHBUILDER S700 MODULE AND APPLICATION OVERVIEW
timer expires. You can also use the user interface to add static forwarding
addresses that the bridge will not delete after the aging timer expires.
When the packet arrives, the bridge looks up the destination MAC address to
determine the destination of the packet from the forwarding tables. If the
destination is found, the bridge forwards the packet to the correct destination. If
the destination is not found, the bridge broadcasts or floods the packet on all
PVCs that are tied to the particular port. If you have assigned a multicast PVC for
that particular port, the bridge will forward the packet to the port multicast VC
instead of broadcasting it.
The PathBuilder S700 performs LLC-based multiplexing per RFC 1483, and
Ethernet frames are bridged.
Filtering
The first bridging operation determines if the packet is to be processed and
transmitted across the bridge or filtered out based on the list of protocols and
addresses input as part of the PathBuilder S700 configuration. Filtering gives you
control over who communicates with whom in the network. The CPU reads the
header of each packet to determine the protocol, source address, and destination
address and then looks in the list to see if the packet should be passed through
the bridge. If it is to be filtered out, it is cleared from memory.
Addressing
The next bridging operation determines if a packet is addressed to another unit on
the LAN (in which case it can be rejected) or if it is addressed to a unit across the
bridge.
As mentioned above, each Ethernet packet includes a source address and a
destination address in its header. These are MAC addresses which are unique
physical addresses assigned to every Ethernet interface on every Ethernet LAN.
Packet transmission from one unit to another on the same LAN is accomplished
easily. However, packet transmission between units on different LANs requires a
higher-level addressing scheme.
Learning Bridge
The aggregate of VPIs/VCIs assigned to a slot and port (Ethernet connection) of
the PathBuilder S700 is referred to as a bridge. Since the PathBuilder S700 reads
and stores MAC addresses and associated VPIs/VCIs as described above, the bridge
is called a learning bridge. Each learning bridge of the PathBuilder S700 has a
separate forwarding table containing the MAC addresses to VPI/VCI associations.
When a learned entry is stored in a forwarding table, it is time tagged. An aging
timer in the PathBuilder S700, which you can set, purges entries from the
forwarding tables after the specified time. The bridges must then relearn purged
addresses. This controls the size of the forwarding tables, particularly in large
networks.
In the PathBuilder S700, each bridge also has a static table associated with it. You
can enter MAC addresses and corresponding PVCs into the static table that you do
not want to be affected by the aging timer. These entries might be for LAN units
that are permanent and are accessed through the ATM network frequently, such
as servers.
Supported Applications
87
The example in Figure 47 shows only one transmission path: the DS3 UNI between
the two PathBuilder S700s. As a result, cells leaving PathBuilder S700 A on VPI/VCI
1/33 arrive at PathBuilder S700 B on VPI/VCI 1/33. If the DS3 trunk were switched
through a standard telephone switching system to interconnect many PathBuilder
S700s, each PathBuilder S700 would have to have the same VPI/VCI designations
assigned. The ATM switch removes this restriction.
Figure 50 shows several PathBuilder S700s in an ATM-switched network. The
switch maps one VPI/VCI into another based on the destination of the packets in
the cell, in the process learning the complete topology of the network. Each
PathBuilder S700 connected to the switch can be configured independently.
Figure 50 Virtual Circuits in a Switched Network
PathBuilder S700 A
VPI/VCI 1/3
PathBuilder
PathBuilder S700 B
S700
ATM
Switch
VPI/VCI 4/6
PathBuilder
S700
PathBuilder S700 C
VPI/VCI 10/23
PathBuilder
S700
Segmentation
Once the CPU determines that a packet should go across the bridge, it
encapsulates the packet per RFC 1483 and adds a pad and trailer conforming to
AAL5 (ATM Adaption Layer 5) at the end of the packet (see Figure 51). The trailer
is fixed at eight bytes and contains information such as the new length of the
packet and cyclic redundancy check bytes (CRC facilitates error checking at the
receive end). The pad is set to 0 to 47 bytes to make the full packet length
including the trailer divisible by 48 bytes. The packet with the RFC 1483
encapsulation is then segmented into 48-byte (384-bit) cells by the SAR function.
Figure 51 AAL5 Pad and Trailer
Trailer
Ethernet Packet
PAD
(0-47 Bytes)
Reserved
2 Bytes
Length
2 Bytes
CRC
4 Bytes
88
CHAPTER 4: PATHBUILDER S700 MODULE AND APPLICATION OVERVIEW
The cells are assigned to a virtual circuit defined between the incoming and
outgoing ports based on the destination address of the original packet. A 5-byte
header containing the virtual circuit assignment along with other information is
added to each cell. The cells are queued in the output FIFO (First In First Out)
memory of the Ethernet Module based on the bandwidth and quality of service
requirements assigned to the virtual circuit at configuration. The FIFO provides
elastic storage between the Ethernet Module and the STX module which may be
polling and multiplexing up to 14 Ethernet modules.
Reassembly
When the STX Module receives a cell from the DS3 UNI Module (or other ATM
module), it broadcasts it to all Ethernet Module ports. As cells are received by the
reassembler, their header is read by the CPU to determine if they belong to the
port. If so, the header is stripped and the cell is stored in memory appended to the
previous ones for that virtual circuit.
The CPU also looks for the AAL5 trailer that signifies the end of a packet. When it
finds a trailer, it performs the CRC calculation, checks the length of the cells since
the previous trailer to be sure no cells were missed, strips the trailer, appends the
cell to the others to reform the original packet, and sends the packet through the
Ethernet I/F to the LAN.
Spanning Tree
Spanning Tree (IEEE 802.1d) is a technique that detects loops in a network and
logically blocks the redundant paths, ensuring that only one route exists between
any two LANs. It eliminates the duplication of packets and provides fault tolerance
for resilient networks.
As the Spanning Tree is being constructed, bridges exchange information, which is
transmitted in packets called Configuration Bridge Protocol Data Units (C-BPDUs).
During this process, the Spanning Tree Algorithm and Protocol (STAP) module
elects a root bridge in order to establish a stable spanning tree topology. The root
bridge determines the spanning tree topology and controls which bridges block
packets and which forward packets.
Once the topology is stable, all STAP bridges listen for special “Hello” C-BPDUs
transmitted from the root bridge at regular intervals (usually every two seconds). If
a STAP bridge timer expires before receiving a “Hello” C-BPDU, it assumes that the
root bridge, or a link between itself and the root bridge, has gone down. It then
initiates a reconfiguration of the Spanning Tree.
When a port goes down (for instance, when an ATM VC is deleted), the port card
notifies the STAP module of such a change. The STAP module then reinitiates the
process of electing a root bridge, and the Spanning Tree calculation process begins
all over again.
Supported Applications
89
Spanning Tree Operation
The Spanning Tree operates as follows:
For more detailed information about how the Spanning Tree operates, see
IEEE802.1d.
n
An STAP module runs as a task on the management card. This task is
responsible for maintaining all data structures for Spanning Tree operation for
all ports and for sending/receiving Spanning Tree configuration packets.
n
Spanning Tree Bridge configuration Protocol Data Units (BPDUs) are received at
Ethernet port cards (on Ethernet and ATM ports) and are sent to the STAP
module on the management card.
n
The management card STAP module examines the packet, reads the MAC
address of the sender, and analyzes the costs reported by the sender.
n
When state of a port changes, the STAP module notifies the port card of the
change.
n
When a port card receives change information for a port, it updates the
operational state of the port so as to change the bridging operation on the
port. For instance, if a port in a forwarding state (normal operation mode of
receiving and forwarding packets) is discovered to be forming a loop, it can be
put in a blocking state. Once the port goes in the blocking state, the port card
will stop receiving frames on the port.
Spanning Tree Instances
The Spanning Tree logic supports a maximum of 255 physical and virtual ports,
thereby allowing a maximum of 254 ATM VCs. (One Ethernet port is required be
set aside for other purposes.)
For the purpose of Spanning Tree operation, each set of one Ethernet port and its
associated ATM VCs is treated as one bridge entity. The STAP module runs a
separate instance for each bridge entity. Since the PathBuilder S700 shelf can be
filled with a maximum of 14 Ethernet cards, each with two Ethernet ports, a
maximum of 28 instances of STAP can be running on the management card.
Each STAP instance runs independently of the other STAP instances and processes
configuration packets as if they came from a different physical bridge device. This
approach helps segregate Ethernet ports completely for the purposes of bridging
and Spanning Tree and enables the PathBuilder S700 to operate as 28 separate
bridges.
VC-VC Bridging operation The Ethernet module supports full-mesh bridging
between its Ethernet port and all of its associated VCs. This bridging must be
bidirectional and should be conditional upon the operational status of the
Spanning Tree. If Spanning Tree operation is disabled, VC-VC bridging is not
necessary since the PathBuilder S700 is not expected to forward traffic coming
from the ATM network.
For instructions on enabling and disabling the Spanning Tree, see “Enabling and
Disabling the Spanning Tree” in Chapter 5.
90
CHAPTER 4: PATHBUILDER S700 MODULE AND APPLICATION OVERVIEW
CBR Application
The CBR module consists of 4 or 8 DSX-1/E1 interfaces capable of accepting
superframe or extended superframe DS1 inputs. The DS1 signal is then mapped
over a Constant Bit Rate (CBR) virtual channel. Encapsulation of the T1 within the
ATM service is based on the ATM Forum (AF-SAA-0032.000) Circuit Emulation
Service Interoperability specification. The ATM Forum specification designates two
modes of operation:
Structured —Modeled after fractional T1. Only the timeslots which will be used
are sent.
Unstructured —Merely encapsulates the entire DS1 onto an ATM path. It allows
timing and FDL to pass through.
Structured DS1
Implement the structured service if you require DS0 midspan drop-and-insert. See
Figure 52.
Figure 52 CBR Structured DS1
B
A
DS0 = 5
ATM DS1
A
DS0 5 = VP 0/VC 35
B
Structured CBR traffic
C
ATM Network
C
DS0 = 5
Channel
Bank
DS0 = 5
ATM DS1
DS0 5 = VP 0/VC 35
PathBuilder
S700
Structured CBR traffic
ATM Network
Public Switched
Telephone
Network
DS0 = 5
PathBuilder S700
Channel
Bank
PathBuilder
S700
Public Switched
Telephone
Network
A
Channel bank converts analog signal to T1; putting voice channel on DS0 5.
B
PathBuilder S700 puts DS0 5 on virtual circuit (VP 0/VC 35) and passes structured CBR traffic through to
the ATM network.
PathBuilder S700
C ATM network continues to carry CBR traffic on to another ATM network or drops the traffic (on DS0 5) to
a public switched telephone network.
Midspan drop and insert allows services such as public switched telephone service
to be inserted into the ATM link. Combining this service with Ethernet bridge
service provides you with a complete integrated communications access solution.
See Figure 53.
Supported Applications
91
Figure 53 Integrated PathBuilder S700 Application
PBX or Key
System
PBX or Key
System
Public Switched
Telephone
Network
Drop
DS0 = 6
DS0 = 1-6
Voice
PathBuilder
ATM Network
S700
PathBuilder
S700
LAN
Data
Ethernet
LAN
Ethernet
LAN
Drop-and-Insert DS0 channels can also be allowed to transit the entire path. This
provides DS0 to DS0 connectivity between end locations. Structured DS0s can be
groomed to be combined through an ATM network allowing end to end DS0
switching as shown in Figure 54.
Figure 54 Structured DS0 Combining
DS1
PathBuilder
S700
10 DS0
PathBuilder
10 DS0
S700
Structured DS0
Grooming
DS1
PathBuilder
S700
ATM Network
Up to 24 Timeslots
PBX - Private Branch Exchange
VCC - Virtual Channel Connection
92
CHAPTER 4: PATHBUILDER S700 MODULE AND APPLICATION OVERVIEW
DS0 Signaling and Dynamic Bandwidth Allocation
Structured DS0s provide channel associated signaling (CAS) by providing a path
for DS0 ABCD bits. See Figure 55.
Channel associated signalling allows telephone supervision to be signaled end to
end. Note that structured DS1 CBR occupies only the needed bandwidth for the
DS0s selected.
Figure 55 Channel Associated Signaling
DS0
A&B Bits
PathBuilder
PathBuilder
S700
S700
Channel Associated
Signaling (CAS)
Channel
Bank
These frames are then followed by the ABCD bits of each active DS0. Two DS0s
ABCD bits are provided in each byte after the last DS0 group. Figure 56 illustrates
an example of 3 DS0s and their ABCD bits sent in a structured encapsulation.
Figure 56 Multiframe Structure for 3x64kbit/s DS1 or E1 with CAS
AAL1 Pointer
First Transported Octet of Multiframe
Second Transported Octet of Multiframe
First 125 µsec Frame of Multiframe for
DS1
Second 125 µsec Frame of Multiframe for
DS1
...
ABCD for
First
Transported
Timeslot
Last 125 µsec Frame of Multiframe for
DS1
Signaling
Substructure
ABCD for
Third
Transported
Timeslot
ABCD for Second
Transported Timeslot
Supported Applications
93
The PathBuilder S700 software can also monitor a full 8-bit pattern on a DS0 to
determine circuit activity. This is the basis for the two supported types of dynamic
bandwidth allocation (DBA):
n
Structured voice DBA
n
Structured data DBA
Structured Voice DBA When a CBR port is configured as structured voice,
signaling bits of voice channels are carried along with their payload in AAL1 cells.
These signalling bits, which are received from T1/E1 framers, are stored in buffers
provided in the SAR processor. The CBR software periodically reads the stored
signaling bits and checks for an idle condition of voice channels with on-hook
detection enabled.
n
When an on-hook (idle) signal is detected, the CBR virtual circuit is deactivated,
and the bandwidth reserved for that channel is released for other uses (such as
VBR traffic).
n
When an off-hook signal is detected, the CBR virtual circuit is activated.
Structured Data DBA When a CBR port is configured as structured data, only
DSO payload bytes are carried in AAL1 cells. These data cells are stored in buffers
provided in the SAR processor. The CBR software periodically reads the stored data
bits and checks for an idle code in the stored data bits of each DS0 channel. All
virtual circuits in the port use a user-selected DBA bit mask to mask off bits that
are not a portion of the idle code.
n
When an on-hook condition (idle code) is detected, the CBR virtual circuit is
deactivated, and the bandwidth reserved for that channel is released for other
uses.
n
When an off-hook condition (no idle code) is detected, the CBR virtual circuit is
activated.
A structured DS1 channel will not pass the original DS1 frame to the remote end.
For instance, ESF network management will terminate at the PathBuilder S700 on
a structured DS1, so CSU to CSU Facility Data Link (FDL) communication will not be
possible. FDL communication is possible with unstructured DS1.
Unstructured DS1
Implement unstructured DS1 service when you want DS1 tunneling through an
ATM system. DS1 tunneling allows an entire DS1 frame including framing bits to
transit an ATM networks. See Figure 57.
94
CHAPTER 4: PATHBUILDER S700 MODULE AND APPLICATION OVERVIEW
Figure 57 DS1 Unstructured Tunneling
T1
Unstructured
Data
Service
Unit
Data
Service
Unit
ATM Network
PathBuilder
PathBuilder
S700
S700
Channel
Service
Unit
Channel
Service
Unit
DS1 Signal Tunneled Through a PVC
Use unstructured services when DS0 midspan access is not required and end to
end DS1 service is required, for example to provide CSU or DSU end to end
connectivity. The encapsulation of unstructured DS1 occupies DS1 bandwidth on
the VCC and uses AAL 1 SAR, as shown in Figure 58.
Figure 58 AAL1 Unstructured DS1
Unstructured DS1
DS1 Frame
Structured DS1
FEC for SN/CSI
Signaling
A/D Converter
Lost Cell
Detection
Clock Recovery
DS0 DS0 BLANK A & B
CSI
1 Bit
AAL 1
VCC
ATM Header
5 Bytes
SC
SNP
3 Bits 4 Bits
SAR-SDU
AAL Layer
47 Bytes
AAL 1 Data
48 Bytes
CSI - Convergence Sublayer Indicator
FEC - Forward Error Correction
SNP - Sequence Number Protection
SC - Sequence Count
SAR - SDU - Segmentation and Reassembly Service Data Unit
VCC - V irtual Channel Connection
ATM Layer
SAR
Supported Applications
95
Structured versus Unstructured Summary
Use Table 30 to select whether to use structured or unstructured DS1 CBR.
Table 30 Selecting Structured Mode Versus Unstructured Mode
Structured
DSO midspan drop and insert
X
DSO access grooming
X
Unstructured
DS1 network management end to end
X
DS1 end to end
(no DSO access)
X
X
DS1 CBR 1.536 Mbps of bandwidth
X
X
DS1 CBR 1.544 Mbps of bandwidth
X
Dynamic Bandwidth Allocation (DBA)
X
Figure 59 depicts the effects of structured versus unstructured service on the
DS1/E1 framing.
Figure 59 Structured Versus Unstructured Effects on Transit DS1
PathBuilder S700
Interface
DS1
AAL 1
DS0
DS0
DS0
DS0
ABCD
ESF
FDL
DS1 Structured N x 64 Kbps
Bit
Bucket
PathBuilder S700
DS1
AAL 1
Interface
DS1
ESF
FDL
DS1 = 1,544 Mbps
DS0 = 64 Kbps
DTE
Timing
DS1 Unstructured
DS - Digital Signal
ESF - Extended Superframe
Ethernet and Voice
Application
A typical configuration involves multiple PathBuilder S700s connected through an
ATM network that could consist an ATM switch or an ATM network consisting of
multiple switches. This configuration is shown in Figure 60.
96
CHAPTER 4: PATHBUILDER S700 MODULE AND APPLICATION OVERVIEW
Figure 60 Typical PathBuilder S700 Configuration
CSU #2
PBX 2
Structured
Input
LAN
2
CSU #1
PathBuilder
Unstructured Input
PathBuilder S700 #2
Port P1
LAN
1
ATM
Switched
Network
DS3 UNI 1
PathBuilder
DS3 UNI 2
Port P2
PBX 3
Port P3
S700
PathBuilder S700 #1
S700
DS0 Drop and Insert
Via Structured DS1
CBR
DS3 UNI 3
CSU #3
DS1 Tunnel Through
Unstructured DS1 CBR
PathBuilder
S700
LAN
3
PathBuilder S700 #3
CSU #4
Circuits Set Up on The PathBuilder S700 #1
Circuits Set Up on the PathBuilder S700 #2
PVC
END1
END2
VPI/VCI
Conn To
PVC
END1
END2
VPI/VCI
Conn To
#1
LAN1
DS3
0/200
LAN2
#1
LAN2
DS3
0/100
LAN1
#2
LAN1
DS3
0/300
LAN3
#2
LAN2
DS3
0/300
LAN3
#3
CSU1
DS3
0/500
CSU4
#3
PBX2
DS3
0/400
PBX3
Circuits Set Up By The Carrier (Cross Connects)
Circuits Set Up on the PathBuilder S700 #3
PVC
END1
VPI/VCI1
END2
VPI/VCI2
PVC
END1
END2
VPI/VCI
Conn To
#1
P1
0/200
P2
0/100
#1
LAN3
DS3
0/100
LAN1
#2
P1
0/300
P3
0/100
#2
LAN3
DS3
0/200
LAN2
#3
P2
0/300
P3
0/200
#3
PBX3
DS3
0/300
PBX2
#4
P2
0/400
P3
0/300
#4
CSU4
DS3
0/500
CSU1
#5
P1
0/500
P3
0/500
Forward and Reverse VCCs Match in This Example. VCCs are Unidirectional. Only Forward Vccs are Shown for
Easier Viewing.
Supported Applications
97
Figure 61 shows three PathBuilder S700s connected through a carrier ATM
network or a private switch. The ATM switch or network should be configured
with Permanent Virtual Circuits (PVCs) connecting one LAN or DS1 port on one
PathBuilder S700 to another port on another PathBuilder S700.
Figure 61 ATM Bridging
Forward Table
ATM
MAC Address
VP0/200 02608C456123
VP0/300 02608C123456
PathBuilder S700 B
PathBuilder
Ethernet
Port
S700
Bridge VP0/200
VP0/300
DS3
UNI
02608C456123
ATM
Network
PathBuilder
S700
PathBuilder S700 C
02608C123456
PathBuilder S700 A
Note that the numbers given for these circuits by the carrier are local to one
PathBuilder S700 and have no global significance. For example, VCC number
0/100 is used on two different PathBuilder S700s to mean two different circuits.
The carrier will assign each PathBuilder S700 at each location any number of
circuits to connect each PathBuilder S700 Ethernet port to any other PathBuilder
S700 Ethernet port desired.
The connections in the carrier network are shown for illustration only. Figure 61
shows an example for an ATM switch configuration. Note that the VCC numbers
get translated by the ATM switch since they have local meaning only for every
switch port. For example, the carrier would provide the PathBuilder S700 at the #1
location, four VCCs for the forward and reverse path to connect respectively to
LAN2 and LAN3. VCCs are unidirectional; therefore, two VCCs are designated on
a port of an PathBuilder S700 to transmit to, and receive from, another location.
The PVCs are provisioned by the carrier for use on each PathBuilder S700. These
PVCs are entered in circuit tables within each PathBuilder S700. After these circuits
are built the bridge can use this information to send ATM cells to remote sites.
The PathBuilder S700 supports a maximum of 256 VCs per IMA group, 4000 VCs
for the whole shelf. You first configure each PathBuilder S700 with the PVC
information using menus that prompt you to input specific information about
each Permanent Virtual Circuit. See “Configuring Virtual Circuits” in Chapter 5,
for details.
These PVCs are tied to specific PathBuilder S700 ports (Ethernet slot 4, port 1).
You can associate several PVCs associated to one PathBuilder S700 port. Each PVC
represents the logical circuit being used to connect one PathBuilder S700 port to a
remote PathBuilder S700 port.
98
CHAPTER 4: PATHBUILDER S700 MODULE AND APPLICATION OVERVIEW
Once you have entered all PVCs, the bridge learns the network addresses for the
local and remote sites and starts bridging packets to the correct destination by
segmenting the packets into cells which are destined to a remote PathBuilder
S700 port. See Figure 61. The ATM network will transport the cells according to
the VPI/VCI headers.
Figure 62 shows three PathBuilder S700s configured to provide LAN connectivity
between three different LAN segments. This example is a simple configuration
which only uses 1 port on 1 Ethernet port card in each PathBuilder S700.
Figure 62 LAN Connectivity
Circuits Set Up on PathBuilder S700 #2
PVC END1 END2 VPI/VCI Conn To
#1
LAN2
DS3
0/100
LAN1
#2
LAN2
DS3
0/300
LAN3
PathBuilder S700 #2
LAN
2
PathBuilder
S700
DS3 UNI 2
Bridge
Table
LAN
1
Forward Known
DS3 UNI 1
Broadcast
Unknown
PathBuilder
S700
PathBuilder
S700 #1
Port P1
ATM
Switched
Network
Port P2
Port P3
Circuits Set Up by the Carrier
PVC END1 VPI/VCI1 End2 VPI/VCI2
#1
P1
0/200
P2
0/100
#2
P1
0/300
P3
0/100
#3
P2
0/300
P3
0/200
Circuits Set Up on PathBuilder S700 #1
PVC END1 END2 VPI/VCI Conn To
#1 LAN1 DS3
0/200
LAN2
#2 LAN1 DS3
0/300
LAN3
Forward and Reverse VCCs Match in
this Example. VCCs are Unidirectional.
DS3 UNI 3
PathBuilder
S700
LAN
3
PathBuilder S700 #3
Circuits Set Up on PathBuilder S700 #3
PVC END1 END2 VPI/VCI Conn To
#1
LAN3
DS3
0/100
LAN1
#2
LAN3
DS3
0/200
LAN2
Each Ethernet port will run Bridging (Learning) programs to determine if received
LAN packets should be passed to the WAN on a specific PVC. In the example
shown in Figure 62, multi-port bridging software will determine if packets will be
passed or dropped. When a packet comes in from LAN 1 port and the Bridge code
does not have the destination MAC address associated with one of its logical ports
(Ethernet, PVC #1, PVC #2), it will broadcast the packet on all PVCs attached with
this port. Once Packets are received from the WAN on specific PVC logical ports,
their source addresses will be learned and associated with the logical port. Once
you and your carrier have set up PVCs to all remote PathBuilder S700 Ethernet
ports, the Bridging code will do the rest. For further information on bridging, see
“Bridging” later in this chapter.
Supported Applications
Frame Application
99
The QSIM/HSIM/FAM modules support 3 modes of Frame to Cell transit services:
n
DXI Mode 1A
n
Frame Relay Forum Specification 5 and 8; Service and Network Interworking
n
HDLC/SDLC
Each service is designed to support a different type of user application. However,
they all share the same ATM backbone characteristics. The QSIM/HSIM/FAM port
modules are mapped over ATM PVCs.
When you are connecting the PathBuilder S700 to an ATM network, verify that the
PVC mapping for in and out ports is defined for proper operation. See Figure 63.
Figure 63 PathBuilder S700 to ATM PVC
PathBuilder S700
PathBuilder S700
QSIM
In
VP 0
VC 50
Out
ATM
VP 0 VC 50
VP 10
Out
VC 45
VP 10
VC 45
In
It is also important to select the proper traffic contract from the ATM
switch/service provider. This card should utilize a VBR or CBR circuit set at the
speed of the connected port. See Figure 64.
Figure 64 PathBuilder S700 Traffic Contract
PathBuilder S700
QSIM In
1 Mbps
1 Mbps
CBR or VBR at
1 Mbps
Sustained Cell
Rate
VBR service will work, however the synchronous path will be subjected to possible
discards and delay.
DXI Mode 1A
DXI protocol frame is an HDLC LLC1 frame similar to PPP protocol. In terms of the
brouter, it is easier to implement DXI Protocol since it only requires the brouter to
encapsulate the SDU.
The ATM Forum defines the DXI service in three modes: 1A, 1B, and 2. The
PathBuilder S700 supports Mode 1A, which includes the following features:
n
up to 1023 virtual connections
n
supports an AAL5 transit encapsulation
n
maximum DTE SDU size 9232 bytes
n
Uses 16-bit FCS
100
CHAPTER 4: PATHBUILDER S700 MODULE AND APPLICATION OVERVIEW
Figure 65 shows the application for DXI.
Figure 65 DXI Application
V.35/KS422/X.21/HSSI
64K to 8M to 52M
PathBuilder S700
PathBuilder S700
PVC
ATM
DXI
Mode
1A
ATM
Native
Host
DXI
Mode
1A
DXI Mode 1A is designed to allow legacy routers to utilize frame based
transmission to transit an ATM network to the DXI Mode 1A device (PathBuilder
S700 QSIM/HSIM/FAM), which then performs SAR and AAL5 mapping to an ATM
PVC. See Figure 66.
Figure 66 DXI Router to ATM Connection
Synchronous
V.35
High-speed Serial Interface -HSSI
RS 449/422
Internet Router
IP
DXI
Transport
DXI Link
DXI
Protocol
DS1
DS3
Brouter/DXI
Internet Router
IP
DXI
Transport
DXI Link
Brouter/DXI
DXI
Protocol
DS1
DS3
DXI
DXI Link Synchronous
Transport
V.35
High-speed
Serial Interface -HSSI
AAL 5
RS 449/422
ATM
ATM Cell
DXI Link
Path Layer
Line Layer
AAL 5
Section Layer
ATM Cell
Photonic Layer
DXI
Transport
SONET
ATM
Path Layer
ATM/DSU/SONET
Li L
Through ATM DXI, the DCE allows the DTE to participate in an ATM network. See
Figure 67.
Supported Applications
101
Figure 67 DCE Allows DTE to Participate in ATM Network through ATM DXI
DTE SDU
DTE SDU
AAL 5 CPCS
DXI Data Link
AAL 5 SAR
DXI Data Link
ATM
DXI Physical
DXI Physical
UNI Physical
DXI
UNI
DCE
DTE
DXI protocol defines an open interface between brouter and Data Service Unit.
The Data Service Unit off-loads cell encapsulation services from the brouter. This
allows your current brouter to support ATM simply by supporting V.35 and
High-level Data Link Control (HDLC). The DXI protocol itself is based on HDLC and
provides simple and efficient encapsulation of the Data Service Unit and the
mapping within the HDLC frame to place the brouter data on an appropriate VC.
See Figure 68.
Figure 68 DXI Format Mode 1A Encapsulation
DTE
SDU
DTE Service Data Unit
Error Check
DTE to DSU
DXI Frame
Octet
Flag FCS
1
Data
2
DXI Information Flag
0-9232
2
1
DSU
DSU to ATM
Network
Translation
AAL 5
SAR
AAL 5 CPCS-PDU
01111110
Address Maps
to/from VPI/VCI
SAR-PDU
SAR-PDU
SAR-PDU
SAR-PDU
DXI Protocol Mode 1A
ATM Cell
102
CHAPTER 4: PATHBUILDER S700 MODULE AND APPLICATION OVERVIEW
Frame Relay Interworking Functions
The PathBuilder S700 provides two functions to interconnect a frame relay
network with an ATM network:
n
Service Interworking
n
Network Interworking
These interworking features are described in FRF.5 and FRF.8 respectively. As far as
the interworking function is concerned, the major difference between these two
features is that there is no FR-SSCS function required for Service Interworking.
The following sections describe the details of these two functions as well as the
features provided by the PathBuilder S700.
Service Interworking Function Figure 69 shows an PathBuilder S700 with
Service Interworking function between a Frame Relay and ATM services. In this
setup, a Frame Relay DTE will be communicating with an ATM DTE, but neither
one knows there is a different type of DTE sitting at the other end.
In this interworking scheme, the application on the frame DTE passes its data
through Q.922 core service. It assumes there is an end-to-end pipe to carry its data
from its end to the other DTE at the far end.
Figure 69 Frame Relay/ATM Service Interworking Connection
Frame
Relay DTE
Frame
Relay DTE
LAPD Frames
Frame
Relay
Network
ATM
Cells
PathBuilder
S700
ATM
Network
ATM
DTE
Application
Q.922
DL Core
PHY
Application
Q.922
DL Core
PHY
Null SSCS
AAL 5
Q.922
DL Core
SAR
ATM
PHY
PHY
Application
Null SSCS
AAL 5
SAR
ATM
PHY
The Q.922 core sees only a point-to-point link to the next connection point. It has
no knowledge about what type of network is behind the current link. On the
other end, the application residing in ATM DTE passes its data through a NULL
SSCS that sits on top of AAL 5. What this ATM DTE sees is the ATM network to
which it is connected. The PathBuilder S700 sitting in the middle performs all the
required translation and management functions between these two networks and
implements the stacks as indicated above in Figure 69.
Supported Applications
103
You can configure each port on a QSIM, HSIM, or FAM module independently to
provide this type of service, and the PathBuilder S700 will perform the following
functions:
n
Q.922 Frame to ATM AAL 5 PDU translation and vice versa
n
Frame PVC Management
n
Traffic Management
n
Congestion Handling
Network Interworking Function Figure 70 shows how an PathBuilder S700
fits into a network interworking configuration.
Figure 70 Frame Rely/ATM Network Interworking Connection
Frame
Relay
Network
Frame
Relay
DTE
Frame
Relay
DTE
Frame
Relay
Network
PathBuilder
S700
ATM
Network
PathBuilder
S700
Application
Frame
Relay
DTE
Frame
Relay
DTE
Application
Q.922
DL Core
Q.922
DL Core
FR-SSCS
AAL 5
SAR
ATM
FR-SSCS
AAL 5
SAR
ATM
Q.922
DL Core
Q.922
DL Core
PHY
PHY
PHY
PHY
PHY
PHY
In this configuration, a Frame Relay DTE communicates with the other Frame Relay
DTE through an ATM network. The Frame Relay DTE at either end works exactly
the same way as that in the service Interworking configuration. It passes its data
through Q.922 core service, assuming that there is an end-to-end pipe to carry its
data from its end to the other DTE at the far end. On the other hand, the
application resides in a Frame DTE instead of an ATM DTE. The PathBuilder S700
performs all the required translation and management functions between these
two networks.
HDLC/SDLC
The PathBuilder S700 will SAR AAL5 and map HDLC/SDLC frames on to an ATM
VCC. You can use the HDLC service for:
n
Router to Router Links
n
X.25 to X.25 Links
n
Other HDLC User
104
CHAPTER 4: PATHBUILDER S700 MODULE AND APPLICATION OVERVIEW
You can use the SDLC service for:
n
IBM FID2 3270 SNA Peripheral
n
IBM FID4 372X SNA Backbone
n
Other SDLC User
Figure 71 shows HDLC/SDLC applications.
NRZI should be disabled on the FEP (i.e. IBM 3745). NRZI is commonly used when
the FEP is connected to DSUs over non-digital line. PathBuilder S700 does not
require NRZI to be enabled.
Figure 71 HDLC/SDLC Applications
PathBuilder
S700
HDLC
PathBuilder
S700
HDLC
X.25
X.25
X.25
PAD
X.25
S
N
A
Host
3
7
2
5
FID 4
SDLC
FID 2
SDLC
3
7
FID 4 2
5
FID 2 3270
5
CONFIGURING PATHBUILDER S700
MODULES, PORTS, AND APPLICATIONS
This chapter tells you how to configure the modules, circuits, and related
applications supported by the PathBuilder S700 WAN access switch
(PathBuilder S700) so that the device can pass traffic. It contains the following
sections:
Viewing and
Configuring System
Information
n
Viewing and Configuring System Information
n
PathBuilder S700 Configuration Overview
n
Configuring the PathBuilder S700 Shelf and the Application Modules
n
Configuring the Shelf
n
Configuring the Management CPU
n
Configuring Virtual Interfaces
n
Configuring Input Shapers
n
Configuring the STX Module
n
Configuring OC3/STM-1 UNI Modules
n
Configuring DS3 UNI Modules
n
Configuring E3 UNI Modules
n
Configuring DS1 UNI or E1 UNI with IMA Modules
n
Configuring Ethernet Modules
n
Configuring DSX-1 CBR or E1 CBR Modules
n
Configuring QSIM/HSIM/FAM Modules
n
Configuring Virtual Circuits
The System Administration menu, shown in Figure 72, includes options that allow
you to view and configure system information. In addition to using this menu for
initial configuration, as described in Chapter 3, you can:
n
Specify general system information.
n
Manage the system clock.
n
View system parameters for the RS-232 ports.
n
View the current firmware version.
n
Download new firmware.
n
Update the flash file system.
n
Reset the interface card.
n
View an equipment list.
The following subsections describe these System Administration menu options.
106
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Figure 72 System Administration Menu
Specifying General
System Information
General system information includes the following:
Shelf name—Change the name of the node.
Customer name—Change or enter the customer name.
Phone number—Change or enter the phone number.
Maintenance contact—Change or enter the maintenance contact.
Location—Change or enter the location.
Auto logout time—Change the logout time (1-99 minutes).
Password—Change the password. The default is password.
To specify or change general system information, follow these steps:
1 From the System Administration menu, select [1] General System Information to
display the General System Information menu shown in Figure 73. This menu
displays the current system information and provides options that allow you to
change the current settings.
2 Select the option corresponding to the setting you want to change. A prompt
appears at the bottom of the screen.
3 Enter the new setting.
4 Repeat steps 2 and 3 for any other settings you want to change.
5 Select [8] Previous Menu to return to the System Administration menu.
For information about the options related to initial configuration (setting
communication parameters, configuring in-band management, setting the time
and date, changing the default password, and taking over a read-write session),
see Chapter 3.
Viewing and Configuring System Information
107
Figure 73 General System Information Menu
Managing the System
Clock
You can manage the system clock for the PathBuilder S700 in the following ways:
n
Specify the clock sources to be used for system timing. You can set up to eight
priority clock sources, including multiple ports of the same card,
n
Specify the clock mode: revertive or non-revertive
n
(revertive mode only) Set the revertive time—the length of time the system
monitors the highest priority system clock source before either reverting to it (if
it has become operative) or continuing to use a lower priority clock source.
To manage the system clock, follow these steps:
1 From the System Administration menu, select [4] Manage System Clock to display
the System Clock Configuration menu, shown in Figure 74.
Figure 74 System Clock Configuration Menu
108
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
2 Specify the clock sources to be used for system timing.
a From the System Clock Configuration menu select: [3] Set PriorityClock 1 to
open the Priority Clock Configuration menu, shown in Figure 75.
Figure 75 Priority Clock Configuration Menu
b Select the option corresponding to the clock source you want to use for the
system reference clock. In addition to the internal clock, you can designate any
of the following cards as clock source:
n
BITS
n
CBR, port n (n=1-4 for 4-port card or 1-8 for 8-port card)
n
DS3
n
E3
n
OC3
n
IMA, port n (n = 1-8)
n
FAM, port n (n = 1-8)
You can designate a card or a port as a clock source even if it has an alarm;
however, the card or port must be In Service. If a card or port is Out of Service, it
will not appear as an option on the Priority Clock Configuration or Reference Clock
Port Selection menu.
c If you selected a non-multiple port clock source (Internal, BITS, DS3, E3, or
OC3) in step b, skip to step h; otherwise continue with step d.
d If you select a card that has multiple ports (CBR, IMA, or FAM), a reference
clock selection menu opens when you select that card as a clock source.
Figure 76 shown the CBR Reference Clock Selection menu. The reference clock
selection menus for the other multiple port cards are similar.
Viewing and Configuring System Information
109
Figure 76 CBR Reference Clock Selection menu
e Select the option corresponding to the card and slot number you want to
designate as the clock source to open the reference clock port selection menu.
This menu lists all the In Service ports on the selected card.
f Select the option corresponding to the port you want to designate as the clock
source.
g Return to the System Clock Configuration menu.
h Repeat steps 2a-2g for up to seven additional clock sources (you can set up to
eight), substituting the appropriate option ([4] -[10]) for [3] Set PriorityClock 1
in step a.
If priority clock #1 fails, priority clock #2 becomes operative; if priority clock #2
fails, priority clock #3 becomes operative, and so on. For a list of the alarm
conditions which cause a clock source to fail, see Table 31 later in this section.
3 Select [1] Set Clock Mode, and set the clock mode to one of the following:
Revertive—If priority clock #1 fails, and priority clock #2 or higher becomes
operative, the system reverts to priority clock #1 if this clock source becomes valid
again within the specified Revertive Time (see step 4),
Non-Revertive—If priority clock #1 fails, and priority clock #2 or higher becomes
operative, the system does not revert to priority clock #1 after it becomes valid
again.
In non-revertive mode only, you can manually switch to priority clock source
#1—or the highest valid clock source. To do this, select [11] Set SysClk to Highest
Priority from the System Clock Configuration menu.
4 (revertive mode only) Select [2] Set Revertive Time and specify the length of time
(10-900 seconds) the system will monitor priority clock #1 before either reverting
to it (if the clock source becomes valid again) or continuing to use a lower priority
clock source.
110
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Alarm Conditions that Cause Clock Source Failure
Table 31 lists the alarms conditions that cause different cards to fail as clock
sources.
Table 31 Clock Source Failure Alarms
Viewing and
Configuring RS-232
Parameters
Card
Alarms
BITS
LOSS OF CLK
CBR
LOS, OOF
DS3
LOS, OOF, LCD (if on PCLP)
E3
LOS, OOF, LCD (if on PCLP)
OC3
LOS, LOF, LOCD
IMA
LOS, OOF
FAM
LOS, OOF
The Management CPU module has two RS-232 ports:
n
Port #1 connects to a local VT100 terminal. You can view the communication
parameters for this port, but you cannot change them via the NMS menus.
n
Port #2 allows you to run PPP. This port can connect via a modem to the user
management network. You can view and configure communications
parameters for this port via the NMS menus.
You must configure your terminal or workstation to match the default settings of
RS-232 port #1 and normally you will want to do the same for port #2.
Table 32 lists the default settings for the RS-232 ports.
Table 32 RS-232 Port Default Settings
Port 1
Port 2
Baud Rate
9600
9600
Parity
none
none
Data Bits
8
8
Stop Bits
1
1
To use other settings for port #2, follow these steps:
1 From the System Administration menu, select [6] RS-232 Port 2 Configuration to
display the RS-232 Port #2 Configuration menu, shown in Figure 77.
Selecting [5] RS-232 Port 1 Configuration displays the current settings only—The
RS-232 Port 1 Configuration menu does not provide options for changing the
communication parameters for port #1.
Viewing and Configuring System Information
111
Figure 77 RS-232 Port #2 Configuration Menu
2 Change any of the following parameters as desired:
Baud Rate—300, 1200, 2400, 4800, 9600, 19200, or 38400
Parity—one, even, or odd
Data Bits—7 or 8
Stop Bits—1 or 2
When you make a change to the port to which you are currently connected, it
does not take effect until you log out. After you log out, change the configuration
of your terminal port to agree with that of the PathBuilder S700 management port
and then start a new session.
Changing to a slower baud rate may slow down communications to the point
where it is obvious on the display (menus will change and form more slowly).
Conversely, increasing the baud rate will speed up the menu system.
Viewing the Firmware
Version
To view the version number for the firmware that is currently running on the CPU:
From the System Administration menu, select [7] Report Firmware Version.
The Report Firmware Version screen appears, as shown in Figure 78.
112
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Figure 78 Report Firmware Version Screen
The Report Firmware Version screen displays the following information about both
the active firmware (the firmware currently being used by the MCPU) and the
standby firmware (the upgradable firmware stored in a standby memory bank):
Version—The released firmware version number. This is the version number that
is displayed on the login screen.
Origins—The original engineering build number for the release.
If the Version and Origins release numbers are the same, then the release is not an
official release but rather a Beta test version.
Who—The user login ID for this software build.
Date—The date and time that the build was made.
Company Name—3Com Corporation (or OEM partner if desired)
Product Name—The PathBuilder product for which this image was built:
PathBuilder S700, PathBuilder S600, PathBuilder S330, or PathBuilder S310.
Downloading New
Firmware
The PathBuilder S700 MCPU module retains the operation firmware in a standby
memory bank. On power-up or reset, the code image is copied from the standby
bank to the active memory bank. The standby memory retains a copy of the
operation firmware. You can upgrade the standby memory in the following ways:
n
Via TFTP over the Ethernet interface, through a Telnet session.
n
Via the Xmodem protocol over the serial port
n
Via FTP
We recommend that you avoid using the serial port to download firmware unless
the Ethernet port is unavailable. Downloading via the serial port can take more
than 30 minutes at 9600 baud.
When you download new firmware, the standby memory is overwritten with the
new code. Once the firmware is successfully downloaded, reset the system to
bring up the new code.
Viewing and Configuring System Information
113
Downloading Firmware via the Ethernet Port
To download new firmware using TFTP, via a telnet session over the Ethernet port,
follow these steps:
Be sure to log in via Telnet. If you log in at a serial port, the download sequence
will attempt an Xmodem protocol download rather than a TFTP download.
1 Obtain the correct image file location and name from 3Com Customer Service.
2 Telnet into the PathBuilder S700 unit.
3 From the System Administration menu, select [8] Download Firmware. The
following prompt appears:
This action will erase the standby code area.
Do you want to download firmware (Y/N) [N]?
4 Enter y and wait for the Ready to download... message.
5 From a workstation or PC (typically the same one doing the Telnet), invoke TFTP
using the PathBuilder S700 IP address.
6 From TFTP, enter the following command:
binary
put <filename>
where <filename> is the filename of the image file to be downloaded.
The download should complete in about two minutes (over lightly-loaded
Ethernet). When the download is finished, the TFTP screen should indicate that the
file is transferred, and the Telnet screen should display the following message:
download complete.
7 From the System Administration menu, select [9] Switch to Standby Code to run
the new firmware. The Switch to Standby Code screen appears. This screen lists
the current code release and the standby code release and displays the following
prompt:
This action will cause a SOFT RESET of the system.
Do you want to switch to standby code (Y/N) [N]
8 Verify that the Standby Code is correct version, then enter y to switch to Standby
Code. The PathBuilder S700 will reboot.
Downloading Firmware via the Serial Port
To download new firmware using the Xmodem protocol over a serial port, follow
these steps:
You must use a terminal emulation program that supports Xmodem protocol.
1 Obtain the correct image file location and name from 3Com Customer Service.
2 Log into the PathBuilder S700 through a serial port.
3 From the System Administration menu, select [8] Download Firmware. The
following prompt appears:
This action will erase the standby code area.
Do you want to download firmware (Y/N) [N]?
4 Enter y to download the new firmware.
The firmware stored in the management terminal is downloaded to the
PathBuilder S700 using the Xmodem protocol. The first step is to erase Standby
114
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Bank and download new firmware into Standby Bank. Prompts advise you of the
progress of the download.
The typical download time at 9600 baud is more than 30 minutes.
5 From the System Administration menu, select [9] Switch to Standby Code to run
the new firmware. The Switch to Standby Code screen appears. This screen lists
the current code release and the standby code release and displays the following
prompt:
This action will cause a SOFT RESET of the system.
Do you want to switch to standby code (Y/N) [N]
6 Verify that the Standby Code is correct version, then enter y to switch to Standby
Code. The PathBuilder S700 will reboot.
Downloading Firmware via FTP
To download new firmware using FTP, follow these steps:
1 Obtain the correct image file location and name from 3Com Customer Service.
2 Log in to the PathBuilder S700 unit.
3 From the System Administration menu, select [8] Download Firmware. The
following prompt appears:
This action will erase the standby code area.
Do you want to download firmware (Y/N) [N]?
4 Enter y and wait for the Ready to download... message.
5 From a workstation or PC, invoke FTP, logging in with the PathBuilder S700 shelf
name and password to get read-write access.
6 From FTP, enter the following command:
binary
put <filename> image
where <filename> is the filename of the image file to be downloaded.
When the download is finished, the FTP screen should indicate that the file is
transferred
7 From the System Administration menu, select [9] Switch to Standby Code to run
the new firmware. The Switch to Standby Code screen appears. This screen lists
the current code release and the standby code release and displays the following
prompt:
This action will cause a SOFT RESET of the system.
Do you want to switch to standby code (Y/N) [N]
8 Verify that the Standby Code is correct version, then enter y to switch to Standby
Code. The PathBuilder S700 will reboot.
Updating the Flash File
System
The flash file system contains system configuration information which is
automatically saved in flash memory at a predetermined interval. To update the
flash file system immediately, rather than at the next scheduled interval, follow
these steps:
1 From the System Administration menu, select [12] Update Flash File System. The
following prompt appears:
Do you want to update the flash file system (Y/N) [N]
Viewing and Configuring System Information
115
2 Enter y to update the flash file system.
The user configuration data is automatically saved into flash memory every
minute. I there is a system failure (a power failure, for example), any changes that
you make during the auto-saving interval will be lost. Thus, we recommend that
you use the [12] Update Flash File System option, as described above, immediately
after you make major configuration changes.
Resetting the Interface
Card
To reset any PathBuilder S700 module, follow these steps:
If you reset the interface card, you will terminate your Telnet session.
1 From the System Administration menu, select [10] Reset Interface Card. The
following prompt appears:
Which slot to reset (1-18)?
2 Enter the number of the slot in which the card you want to reset is installed. The
following prompt appears:
Are you sure you want to reset this card (Y/N) [N]?
3 Enter y to reset the card.
Viewing an Equipment
List
To view information about the modules currently installed on your PathBuilder
S700:
From the System Administration menu, select [11] Show Equipment List. Figure 79
shows a sample Equipment List.
Figure 79 Equipment List
The Equipment List displays the following information for each installed module:
SLOT—A reference number for the ports on the motherboard. This number
corresponds to the number on the List Card menu. (See Figure 78, later in this
chapter.)
116
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Slot numbers 2 and 4 are unused in this release. These slots are reserved for
redundant MCPU and STX modules, which will be supported in subsequent
releases.
CARD-TYPE—The card type: Shelf, MCPU, STX, DS1 UNI (4), E1 UNI (4), OC3 UNI,
DS3 UNI, E3 UNI, QSIM, HSIM, FAM, Ethernet, E1 CBR, or DSX-1 CBR.
An RR notation to the left of the PART#-idprom indicates a rear redundant
module.
PART#-idprom—The part number as programmed at the factory.
PART#-oem—The part number for OEM customers.
SERIAL#—The serial number for the card.
REV#—The revision number for the card.
Backing up and
Restoring the Database
and Code Image
The configuration database is stored in non-volatile flash memory in the
PathBuilder S700. As further protection, 3Com recommends that you back up the
database after any major configuration changes.
A power cycle of the shelf is necessary to synchronize the database on the MCPU
if it is being restored. No additional action is necessary if you are just backing up
the database.
Backing up the Database
To back up the database, follow these steps:
1 Select [1] System Administration to display the System Administration menu.
2 Select [10] Reset Interface Card to display the Reset Port Card screen.
3 Enter [1], for the MCPU card.
4 Enter y at the confirmation prompt to reset the card.
5 Create a directory that will hold only the database files.
6 Move to the directory you created in step 5.
7 FTP to the node (FTP <node>).
n
FTP login will be the node name (upper left hand corner of user interface).
n
FTP password will be the node password (the password used to access user
interface).
8 Switch to binary mode by entering:
binary
9 Change directory to /fileDev/disk by entering:
cd /fileDev/disk
10 Back up all files by entering:
mget *
11 Exit FTP by entering:
bye
Viewing and Configuring System Information
117
Restoring the Database
To restore the database, follow these steps:
You must have read/write access on the node to perform the restore operation.
1 Move to the directory you created earlier, in step 5 under “Backing up the
Database”. This directory should contain only the database files.
2 FTP to the node (FTP <node>).
n
FTP login is the node name (upper left corner of user interface)
n
FTP password is the node password (password used to access the interface)
3 Switch to binary mode by entering:
binary
4 Change directory to /fileDev/disk by entering:
cd /fileDev/disk
5 Restore all files by entering:
mput*
6 Exit FTP by entering:
bye
7 Telnet to the node.
8 Select [1] System Administration to display the System Administration menu.
9 Select [12] Update Flash File System.
10 Enter y at the confirmation prompt to update the flash file system.
Wait for the Update Completed message before continuing to Step 11.
11 Select [10] Reset Interface Card to display the Reset Port Card screen.
12 Enter 1, for the MCPU card.
13 Enter y at the confirmation prompt to reset the card.
14 Repeat steps 11-13 for each card in the shelf.
Backing up the Code Image
To back up the code image, follow these steps:
1 FTP <node>.
n
FTP login will be the node name (upper left hand corner of user interface).
n
FTP password will be the node password (the password used to access user
interface).
2 Switch to binary mode by entering:
binary
3 Change directory to /fileDev/main by entering:
cd /fileDev/main
4 Change directory to /flashDev/main (type “cd /flashDev/main”).
5 Get file image by entering:
get image bootmgmt.abs
118
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
It is not necessary to rename the file image to bootmgmt.abs, but renaming the
file image makes the restore seem the same as a code download.
6 Exit FTP by entering:
bye
Restoring the Code Image
To restore the code image, follow these steps:
1 Move to directory that contains the bootmgmt.abs file.
2 FTP <node>.
n
FTP login will be the node name (upper left hand corner of user interface).
n
FTP password will be the node password (the password used to access user
interface).
3 Switch to binary mode by entering:
binary
4 Verify that the current directory is /flashDev/standby.
5 Put file bootmgmt.abs by entering:
put bootmgmt.abs image
6 Exit FTP by entering:
bye
7 Telnet to the node.
8 Select [1] System Administration to display the System Administration menu.
9 Select [9] Switch to Standby Code to display the Switch to Standby Code screen.
10 Enter y to switch to standby code.
PathBuilder S700
Configuration
Overview
Select [2] Configuration Management from the Main menu to display the
Configuration Management menu, shown in Figure 80. Use this menu to access
submenus and screens that allow you to:
n
Manage cards—View shelf configuration information and configure the
PathBuilder S700 application modules.
n
Manage circuits—List, add, modify, and delete virtual circuits.
n
Manage the bridge—Set the bridge aging timer and configure the bridge.
n
Manage IP over ATM—Configure and enable/disable IP over ATM for
Ethernet ports.
Configuring the PathBuilder S700 Shelf and the Application Modules
119
Figure 80 Configuration Management Menu
The options on the Configuration Management menu correspond to the major
steps involved in configuring the PathBuilder S700:
n
Configuring application modules
n
Setting up virtual circuits and assigning them to the appropriate card’s ports
n
Configuring application-specific options
You can apply specialized functions such as bridging of the LAN traffic and IP
over ATM to virtual circuits as needed and/or supported.
Configuring the
PathBuilder S700 Shelf
and the Application
Modules
The starting point for configuring the PathBuilder S700 shelf and the application
modules is the List Card menu, shown in Figure 81. To display the List Card menu:
From the Configuration Management menu, select [1] Manage Card.
Figure 81 List Card Menu
120
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
The List Card menu lists the PathBuilder S700 shelf and all the modules installed in
the shelf. The numbers correspond to the slot numbers. For each slot number, the
List Card menu displays:
Config Card Type—The type of module configured for the slot.
Actual Card Type—The type of module actually installed in the slot.
Slots 2 and 4 are unused in this release. These slots are reserved for redundant
MCPU and STX modules, which will be supported in subsequent releases.
To access the configuration menu(s) for a particular module, simply enter the
corresponding slot number.
The configured card type must match the actual card type before you can access
the configuration menus for that card. If there is a mismatch between the
configured card type and the actual card type, an error message appears when
you enter the slot number from the List Card menu.
You can reset the slot to match the actual card type by entering y at the following
prompt:
Do you want to configure this slot to match the actual card type (Y/N)?
Press ÔYÕ to match card type or ÔNÕ to return to previous menu.
CAUTION: Changing the card type in a slot will reset all existing configuration
data for that slot.
Setting Application Module Status
The application modules each have an administrative and an operational status (In
Service or Out of Service). You set the administrative status on the appropriate
module configuration menu. The system displays the operational status, also on
the module configuration menu.
When the administrative status is set to Out of Service, the card’s configuration
menu lists the operational status as Out of Service whether or not the card is
actually operational. Once you set the administrative status to In Service, the
operational status listed will indicate the true card status (Out of Service if there is
a card failure or In Service if the card is operational).
To set up a virtual circuit, you must set the administrative status of the card and
port which will carry the circuit to In Service. For details about setting up virtual
circuits, see “Configuring Virtual Circuits” later in this chapter.
The following sections tell you how to configure specific PathBuilder S700
modules.
Configuring the Shelf
From the Shelf Configuration menu, shown in Figure 82, you can get information
about the shelf and configure it by setting and unsetting the power supplies and
setting external alarms.
Configuring the Shelf
121
To display the Shelf Configuration menu, select [0] Shelf from the List Card menu.
Figure 82 Shelf Configuration Menu
The Shelf Configuration menu displays the following information about the shelf:
Setting Power Supply
Status
n
Hardware revision
n
Serial number
n
Power supply status (in service or out of service) for power supplies 1-6
n
External alarm status (normally open or normally closed) for external alarms 1-3
To set the status of a power supply, follow these steps:
1 From the List Card menu, shown earlier in Figure 81, select [0] Shelf to open the
Shelf Configuration menu, shown earlier in Figure 82.
2 Enter the number corresponding to the power supply that you want to set. The
following prompt appears:
Enter Power Supply (1= Out of Service, 2= In Service):
3 Enter 1 to take the power supply out of service or 2 to put the power supply
into service.
Setting External Alarm
Status
The PathBuilder S700 supports up to three alarms from outside equipment. To set
the external alarms, follow these steps:
1 From the List Card menu, shown earlier in Figure 81, select [0] Shelf to open the
Shelf Configuration menu, shown earlier in Figure 82.
2 Enter the number corresponding to the external alarm that you want to set (7 for
alarm #1, 8 for alarm #2, or 9 for alarm #3).
The following prompt appears:
Enter External Alarm 1 (1= Normally Open, 2= Normally Closed)
3 Enter 1 to set the alarm to normally open or 2 to set the alarm to normally closed.
For details about how to connect the external alarms, see “Connecting the Office
Alarms” in Chapter 2.
122
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Configuring the
Management CPU
Configuring the management CPU involves the following tasks:
n
Viewing the current configuration for the CPU module
n
Configuring virtual interfaces
n
Configuring shapers
The MCPU Configuration menu, shown in Figure 83, provides access to the
submenus and screens from which you perform these tasks.
To display the MCPU Configuration menu:
From the List Card menu, select [1] MCPU.
Figure 83 MCPU Configuration Menu
Viewing MCPU
Configuration
Information
To view MCPU configuration information, follow these steps:
1 From the MCPU Configuration menu, select [1] Card Information to display the
following information:
n
Hardware revision
n
Serial number
n
Status (In Service or Out of Service)
2 Press any key to return to the MCPU Configuration menu.
Configuring Virtual
Interfaces
From the MCPU Configuration menu, as well as from other card menus, you can
create and configure virtual interfaces.
A Virtual Interface (VI) represents a group of 4 ATM queues and a bulk shaper
value. When you build a VC (virtual channel) or VP (virtual path), you specify, for
each side, the VI at which the transmit cells are queued and shaped.
Configuring Virtual Interfaces
Adding Virtual
Interfaces
123
n
For the MCPU module (slot 1), you can configure one VI.
n
For modules installed in slots 5 and 6, you can configure up to 15 VIs per
module.
n
For modules installed in slots 7-18, you can configure up to 24 VIs per bus.
Each bus supports three slots (7-9, 10-12, 13-15, and 16-18). You can allocate
all 24 VIs on a particular bus to a single slot, or you can divide them among the
3 slots supported by the bus.
To create a virtual interface, follow these steps:
1 From the List Card menu, enter the slot number corresponding to the card for
which you want to add a virtual interface. The configuration menu for that card
appears.
2 Select the Virtual Interfaces option to display the Virtual Interfaces Configuration
menu. The option number you select varies depending on the card type. From the
MCPU menu shown earlier in Figure 83, for example, you select [3] Virtual
Interfaces.
Figure 84 shows the MCPU Virtual Interfaces Configuration menu. The menus for
the other cards are the same.
Figure 84 Virtual Interfaces Configuration Menu
3 Select [2] Add Virtual Interface. The Add Virtual Interface menu appears, as shown
in Figure 85.
124
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Figure 85 Add Virtual Interface Menu—Selecting the Shaper Rate Unit
4 Enter 1 to configure the shapers in Cps or 2 to configure the shapers in Mbps.
Then press Enter to open the Add Virtual Interface Configuration menu. Figure 86
shows the MCPU Add Virtual Interface Configuration menu. The Add Virtual
Interface Configuration menus for the other cards are the same.
Figure 86 Add Virtual Interface Configuration Menu
5 Select [2] Set Description and enter a description for the virtual interface.
6 Select [1] Set Shaper Rate and select a shaper rate. The range of acceptable shaper
rates is 151 to 367642 cells per second or 64Kbps to 155.88Mbps.
When the shaper rate is set, a prompt similar to the following appears:
VI 1 is updated.
7 Select [3] Previous Menu to return to the Add Virtual Interface Configuration
menu.
8 Repeat steps 3-6 to add additional virtual interfaces as desired.
Configuring Virtual Interfaces
Viewing and/or
Modifying Existing
Virtual Interfaces
125
Once a Virtual Interface has been established, you can modify the values for
Shaper Rate or Description.
To view and/or modify an existing virtual interface, follow these steps:
1 From the List Card menu, enter the slot number corresponding to the card for
which you want to view and/or modify a virtual interface. The configuration menu
for that card appears.
2 Select the Virtual Interfaces option to display the Virtual Interfaces Configuration
menu. Figure 84, above, shows the MCPU Virtual Interfaces Configuration menu.
The menus for the other cards are the same.
3 Select [1] List/Modify Virtual Interface to open the List/Modify Virtual Interface
menu. Figure 87 shows the MCPU List/Modify Virtual Interface menu. The menus
for the other cards are the same.
The List/Modify Virtual Interface menu shows a summary of existing virtual
interfaces, with a virtual interface number (VI#) assigned to each. The menu also
displays the following information for each virtual interface:
n
Rate, in cells per second
n
User-entered description
Figure 87 List/Modify Virtual Interface Menu
4 If you want to modify a virtual interface, enter the number corresponding to the
virtual interface which you want to modify to display the Modify Virtual Interface
menu for the selected virtual interface. This menu is the same as the Add Virtual
Interface menu shown earlier in Figure 86.
5 Change the Shaper Rate and/or Description for the virtual interface as desired.
126
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Deleting Virtual
Interfaces
To delete a virtual interface, follow these steps:
1 From the List Card menu, enter the slot number corresponding to the card for
which you want to delete a virtual interface. The configuration menu for that card
appears.
2 Select the Virtual Interfaces option to display the Virtual Interface Configuration
menu. The option number may vary, depending on the card type.
3 From the Virtual Interface Configuration menu, select [3] Delete Virtual Interface.
The Delete Virtual Interface menu appears. This menu is the same as the
List/Modify Virtual Interfaces menu, shown earlier in Figure 87. It lists the existing
virtual interfaces, with a virtual interface number (VI#) assigned to each.
4 Enter the number corresponding to the virtual interface you want to delete.
5 Enter y in response to the confirmation prompt to delete the virtual interface.
Configuring Input
Shapers
The MCPU, Ethernet, QSIM, HSIM, and FAM modules allow you to configure
shapers based on the Dual Leaky Bucket algorithm. Unlike the virtual interface
shapers described under “Configuring Virtual Interfaces” above, these shapers are
not bulk shapers; rather, they are input shapers that shape the traffic toward the
cell bus per virtual circuit,
The PathBuilder S700 supports three input shaper parameters:
Peak Cell Rate (PCR)—The maximum rate that can be passed.
Sustained Cell Rate (SCR)—The maximum average rate that a bursty, on-off
traffic source can send; used in conjunction with maximum burst size.
Maximum Burst Size (MBS)—The maximum number of cells that can be sent at
the peak rate; used in conjunction with sustained cell rate.
You can configure up to 15 shapers for each supported card. The values that you
set for the shapers are the values that are then available for the Shaper Number
parameter that you set when you configure certain types of virtual circuits. See
“Configuring Virtual Circuits” later in this chapter, for details.
To configure input shapers, follow these steps:
1 From the List Card menu, enter the slot number corresponding to the card for
which you want to configure shapers. The configuration menu for that card
appears.
2 Select the Shaper Configuration option to display the Shaper screen. The option
number you select varies, depending on the card type.
Figure 88 shows the MCPU Shaper screen. The screens for the other cards are the
same. The Shaper screen consists of a table listing the current shaper values in
bits/second (bits for the maximum burst size shaper) and cells/second (cells for the
maximum burst size shaper). Initially, the shapers are set to default values.
Configuring the STX Module
127
Figure 88 Input Shaper Screen
3 To enter a new shaper value, use the arrow keys on your keyboard to move to the
cell in the shaper table that you want to change.
n
To set a new Sustainable Cell Rate or Peak Cell Rate shaper, enter the new value
in the bits/second (bps) column. The system automatically calculates the
cells/second (cps) based on the value you enter.
n
To set a new Maximum Burst Size shaper, enter the new value in the cells
column. The system automatically calculates the bits based on the value you
enter.
How you configure the input shapers depends on the type of service you have.
n
n
If you have a peak rate service:
n
Set the peak rate at the maximum allowable value.
n
Set the sustained cell rate at the same rate as the peak rate.
If you have a sustained rate service:
n
n
Set the peak rate at the line rate (for example 45Mbps for a DS3 line).
Set the sustained cell rate and maximum burst rate at the values given to
you by your service provider.
4 When you are finished, press [ESC] to return to the MCPU Card Configuration
menu.
Configuring the STX
Module
To configure the STX module, follow these steps:
1 From the List Card menu, enter [3] STX to display the STX Module Configuration
menu, shown in Figure 89. This menu displays the current information for the STX
card and allows you to configure the congestion settings for up to three traffic
priority queues.
Option [7] Set Redundancy is disabled in Release 2.03 but will be enabled in future
releases when the PathBuilder S700 supports redundant MCPU, STX, and
application modules.
128
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Figure 89 STX Module Configuration Menu
2 Select the appropriate numbers and enter the desired Congestion On and
Congestion Off thresholds for the priority queues you want to configure. The
ranges are 51%-100% for Congestion On and 0% to 50% for Congestion Off.
You cannot set congestion thresholds for Queue 0, which is the highest priority
queue. This ensures that the traffic passing through Queue 0 is preserved and
treated with highest priority.
The congestion settings indicate the threshold level of cell buffers.
n
When the congestion level of the cell buffer for a particular queue reaches the
Congestion On threshold, a congestion state is declared.
n
When the congestion level falls back to the Congestion Off threshold, the
congestion state is cleared.
n
When the congestion state is set to on, Early Packet Discard (EPD) is initiated
until Congestion State is set to Off.
For example, if you set the Congestion On and Congestion Off thresholds for a
queue to 90 and 45 respectively, a congestion state would be declared when the
cell buffer is 90% full and cleared when the cell buffer is 45% full.
The Congestion On and Congestion Off settings are on a per queue basis, but
once you set the congestion thresholds for a particular queue, those settings are
used for that queue for all cards.
Configuring
OC3/STM-1 UNI
Modules
Configuring an OC3/STM-1 UNI module involves the following tasks:
n
Configuring the card
n
Configuring the virtual interfaces
To configure an OC3/STM-1 UNI module, follow these steps:
1 From the List Card menu, select the slot number corresponding to the OC3/STM-1
UNI module to display the OC3/STM-1 Configuration menu, shown in Figure 90.
Configuring OC3/STM-1 UNI Modules
129
Figure 90 OC3/STM-1 UNI Configuration Menu
2 Configure the OC3/STM-1 card.
a Select [1] Card Information to display the OC3/STM-1 UNI Card Configuration
menu, shown in Figure 91. This menu displays the current configuration for the
OC3/STM-1 UNI module and provides options for changing certain parameters.
Figure 91 OC3/STM-1 UNI Card Configuration Menu
b Set the following parameters as desired:
Admin Status—Administrative Status: In Service or Out of Service.
Sonet Interface Mode—Synchronous Optical Network mode: OC3 or STM-1.
OC3 (SONET) is a high-speed synchronous system technology used on
fiber-optic cable networks. STM-1 (SDH or Synchronous Digital Hierarchy) is the
European equivalent of SONET.
ATM Payload Scramble—Enables (Yes) or disables (No) payload scrambling
for the OC3/STM-1 port. Payload scrambling scrambles the 48-byte payload in
outgoing cells in a defined manner and unscrambles the payload in incoming
130
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
cells. It is a technique used to avoid certain transmission equipment behaviors
(for example, erroneous alarm conditions) that are caused by sensitivity to
certain bit patterns in the ATM payload. You must match this setting at the
two ends of the OC3/STM-1 trunk.
Peak Rate—The peak ATM payload, in Mbps: 1 to 155. This parameter is a
feature specifically designed for the PathBuilder S700. It allows you and your
service provider to traffic shape all connections to an optimum rate, assigned as
part of the ATM service contract.
Timing Source—The timing source for the OC3/STM-1 transmit clock: System
or Loop. If you set the OC3/STM-1 Timing Source to System at one end of the
OC3/STM-1 trunk, you must set it to Loop at the other end.
System—Configures the port interface to use the system reference clock
within the shelf as a reference for transmitting.
Loop—Configures the port interface to use the input port Rx clock as the
timing source; timing is received from the service “loop.” Select this option
if the OC3/STM-1 UNI module is used for the network/carrier service
termination, in which case the carrier (the service “loop”) typically provides
the timing source.
Xmt Ckt ID—The transmit path trace identifier. This is a user-entered identifier
for the transmit circuit of up to either 16 characters (if Sonet Interface Mode is
set to STM-1) or 64 characters (if Sonet Interface Mode is set to OC3). The path
trace is a byte used to repetitively transmit a 64-byte fixed length string so that
a receiving terminal in a path can verify its continued connection to the
intended transmitter.
Number of VPI for VCC—The number of distinct VPIs that can be used for
VCCs on this card: 1..256. Any VPIs not currently in use by VCCs are available
for VPCs.
c Select [8] Previous Menu to return to the OC3/STM-1 Configuration menu.
3 Configure virtual interfaces for the OC3/STM-1 UNI card.
a Select [2] Virtual Interfaces to open the OC3/STM-1 Virtual Interfaces
Configuration menu. This menu is the same as the MCPU Virtual Interfaces
menu, shown earlier in Figure 84.
b Configure virtual interfaces as described under “Configuring Virtual Interfaces”
earlier in this chapter. You configure virtual interfaces for the OC3/STM-1 UNI
card in the same way that you configure virtual interfaces for the MCPU card.
Configuring DS3 UNI
Modules
Configuring a DS3 UNI module involves the following tasks:
n
Configuring the card
n
Configuring the virtual interfaces
To configure a DS3 UNI module, follow these steps:
1 From the List Card menu, select the slot number corresponding to the DS3 UNI
module to display the DS3 UNI Configuration menu, shown in Figure 92. The
options on this menu allow you to access other menus from which you can
configure either card configuration information or virtual interfaces.
Configuring DS3 UNI Modules
131
Figure 92 DS3 UNI Configuration Menu
2 Configure the DS3 card.
a Select [1] Card Information to display the DS3 UNI Card Configuration menu,
shown in Figure 93. The DS3 Card Configuration menu displays the current
configuration for the DS3 module and provides options for changing certain
parameters.
Figure 93 DS3 UNI Card Configuration Menu
b Set the following parameters as desired:
Admin Status—Administrative Status: In Service or Out of Service.
LBO Length—Line Build Out length. The signal generation/regeneration of the
distance between the PathBuilder S700 and the next crossconnect or FOTs
(Fiber Optic Terminal system), in feet: 0-225 or 225-450.
DS3 Framing Mode—The type of frame organization configured for the
specified port interface: Cbit or M23. Set this parameter to match the framing
type offered by your service provider. Cbit is the most common setting, as its
132
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
use of overhead bits for administration and maintenance allows the service
provider more visibility in isolating any issues with the physical line connections
through the WAN. You must match this setting at the two ends of the DS3
trunk.
ATM Cell Mapping—How the carrier will provision the DS3 UNI service from
the carrier ATM switch: Clear (HEC) or PLCP (Physical Layer Convergence
Protocol). Clear is the option preferred by both domestic and international
service providers and within private ATM networks, as it gives more payload
bandwidth than PLCP. You must match this setting at the two ends of the DS3
trunk.
ATM Payload Scramble—Enables (Yes) or disables (No) payload scrambling
for the DS3 port. Payload scrambling scrambles the 48-byte payload in
outgoing cells in a defined manner and unscrambles the payload in incoming
cells. It is a technique used to avoid certain transmission equipment behaviors
(for example, erroneous alarm conditions) that are caused by sensitivity to
certain bit patterns in the ATM payload. You must match this setting at the
two ends of the DS3 trunk.
Peak Rate—The peak DS3 payload, in Mbps: 5.1 to 40.7 if Cell Mapping is set
to Clear; 5 to 40 if Cell Mapping is set to PLCP. This parameter is a feature
specifically designed for the PathBuilder S700. It allows you and your service
provider to traffic shape all connections to an optimum rate, assigned as part
of the ATM service contract.
FEAC Loopback—Enables or disables the system from responding to FEAC
(Far-End Alarm Condition) loopback commands (loopback activate and
deactivate FEAC codes) from the central office. FEAC is a DS3 overhead
function that the service provider may use for establishing loopback for
problem resolution of the network. The service provider uses FEAC codes to
obtain downstream or upstream conditions of a DS3 network. When the FEAC
Loopback option is enabled, the system responds to a loopback activate
command by enabling the DS3 line loopback. The system removes the
loopback automatically after 15 minutes or when it receives the deactivate
command.
DS3 Timing Source—The timing source for the DS3 transmit clock: system or
loop. If you set the DS3 Timing Source to system at one end of the DS3 trunk,
you must set it to loop at the other end.
System—Configures the port interface to use the system reference clock
within the shelf as a reference for transmitting.
Loop—Configures the port interface to use the input port Rx clock as the
timing source; timing is received from the service “loop.” Select this option
if the DS3 UNI module is used for the network/carrier service termination, in
which case the carrier (the service “loop”) typically provides the timing
source.
PLCP Timing Source—The PLCP timing source for the DS3 port:
System Clock—PLCP is timed from the internal 8kHz backplane clock.
DS3 Timing—PLCP is timed from the 8kHz reference clock derived from
the received PLCP.
Configuring E3 UNI Modules
133
STX Timing Source—The timing sent to the STX card: PLCP Clock or DS3 Rx
Clock. This is the clock the system will use if you select the DS3 card as the
timing source from the Priority Clock Configuration menu, shown earlier in
Figure 75,
Number of VPI for VCC—The number of distinct VPIs that can be used for
VCCs on this card: 1..256. Any VPIs not currently in use by VCCs are available
for VPCs.
c Select [12] Previous Menu to return to the DS3 Configuration menu.
3 Configure virtual interfaces for the DS3 UNI card.
a Select [2] Virtual Interfaces to open the DS3 UNI Virtual Interfaces
Configuration menu. This menu is the same as the MCPU Virtual Interfaces
menu, shown earlier in Figure 84.
b Configure virtual interfaces as described under “Configuring Virtual Interfaces”
earlier in this chapter. You configure virtual interfaces for the DS3 UNI card in
the same way that you configure virtual interfaces for the MCPU card.
Configuring E3 UNI
Modules
Configuring an E3 UNI module involves the following tasks:
n
Configuring the card
n
Configuring the virtual interfaces
To configure an E3 UNI module, follow these steps:
1 From the List Card menu, select the slot number corresponding to the E3 UNI
module to display the E3 UNI Configuration menu.
The E3 UNI Configuration menu is the same as the DS3 UNI Configuration menu
shown earlier in Figure 92. The options on this menu allow you to access other
menus from which you can configure either card configuration information or
virtual interfaces.
2 Configure the E3 UNI card.
a Select [1] Card Information to display the E3 UNI Card Configuration menu,
shown in Figure 94. The E3 UNI Card Configuration menu displays the current
configuration for the E3 UNI module and provides options for changing certain
parameters.
b Set the following parameters as desired:
Admin Status—Administrative Status: In Service or Out of Service.
ATM Cell Mapping—How the carrier will provision the E3 UNI service from
the carrier ATM switch: Clear (HEC).
ATM Payload Scramble—Enables (Yes) or disables (No) payload scrambling
for the E3 port. Payload scrambling scrambles the 48-byte payload in outgoing
cells in a defined manner and unscrambles the payload in incoming cells. It is a
technique used to avoid certain transmission equipment behaviors (for
example, erroneous alarm conditions) that are caused by sensitivity to certain
bit patterns in the ATM payload.
Peak Rate—The peak E3 payload Mbps: 5 to 34. This parameter is a feature
specifically designed for the PathBuilder S700. It allows you and your service
provider to traffic shape all connections to an optimum rate, assigned as part
of the ATM service contract.
134
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Figure 94 E3 UNI Card Configuration Menu
E3 Timing Source—The timing source for the E3 transmit clock: system or
loop. If you set the E3 Timing Source to system at one end of the E3 trunk, you
must set it to loop at the other end.
System—Configures the port interface to use the system reference clock
within the shelf as a reference for transmitting.
Loop—Configures the port interface to use the input port Rx clock as the
timing source; timing is received from the service “loop.” Select this option
if the E3 UNI module is used for the network/carrier service termination, in
which case the carrier (the service “loop”) typically provides the timing.
Number of VPI for VCC—The number of distinct VPIs that can be used for
VCCs: 1..256. Any VPIs not currently in use by VCCs are available for VPCs.
c Select [7] Previous Menu to return to the E3 Configuration menu.
3 Configure virtual interfaces for the E3 UNI card.
a Select [2] Virtual Interfaces to open the E3 UNI Virtual Interfaces Configuration
menu. This menu is the same as the MCPU Virtual Interfaces menu, shown
earlier in Figure 84.
b Configure virtual interfaces as described under “Configuring Virtual
Interfaces” earlier in this chapter. You configure virtual interfaces for the E3
UNI card in the same way that you configure virtual interfaces for the MCPU
card.
Configuring DS1 UNI
or E1 UNI with IMA
Modules
The PathBuilder S700 supports both a DS1 UNI and an E1 UNI module with IMA
(Inverse Multiplexing for ATM). The configuration procedure is the same for both
modules, but different parameters are available on the port configuration menu,
as described under “Configuring DS1/E1 UNI Ports” below.
Configuring a DS1/E1 UNI module involves the following tasks:
n
Configuring the individual DS1/E1 ports
n
Setting up and configuring IMA and/or UNI groups (if desired)
n
Viewing IMA link and group status
n
Configuring the DS1/E1 card
Configuring DS1 UNI or E1 UNI with IMA Modules
Configuring DS1/E1 UNI
Ports
135
To configure individual DS1/E1 UNI ports, follow these steps:
1 From the List Card menu, shown earlier in Figure 81, select the number
corresponding to the slot in which the DS1 UNI or E1 UNI card is installed to open
the DS1 or E1 UNI Configuration menu.
Figure 95 shows the E1 UNI Configuration menu. The DS1 UNI Configuration
menu is the same.
Figure 95 E1 UNI Configuration Menu
2 Select [1] Port Configuration open the DS1 UNI or E1 UNI Port Configuration
selection menu. Figure 96 shows a E1 UNI Port Configuration selection menu. The
DS1 UNI menu is the same.
Figure 96 E1 UNI Port Configuration Selection Menu
3 Select the number corresponding to the DS1 or E1 port you want to configure to
open the DS1 UNI or E1 UNI Port Configuration menu.
136
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Figure 97 shows the E1 UNI Port Configuration menu. The DS1 UNI Configuration
menu is similar. These menus display the current configuration for the selected DS1
UNI or E1 UNI port and provide options for changing certain parameters.
Figure 97 E1 UNI Port Configuration Menu
Figure 98 DS1 UNI Port Configuration Menu
4 Set the following parameters as desired:
LBO (DS1 only)—Line Build Out. The setting for the transmit signal level: 0, 7.5,
15, or 22.5 db. The LBO compensates for the distance between the card and the
CSU/repeater. It is a setting for the transmit signal level.
Line Code (DS1 only)—The zero code suppression technique configured to the
DS1 port interface: B8ZS for DS1; HDB3 for E1. This is a read-only parameter.
B8ZS—Binary 8 Zero Substitution; a T1 (1.544Mbps) carrier line coding format
used to accommodate “ones density” for clear channel transmission.
HDB3—High Density Binary 3 zero Substitution; an E1 carrier line coding
format
Configuring DS1 UNI or E1 UNI with IMA Modules
137
Framing—The type of frame organization configured for the T1 port interface:
D4 or ESF for DS1. Set this parameter to match the service provider or device
connection framing. For E1, Framing is a read-only parameter and is always set to
multi-frame.
CAUTION: A framing mismatch can cause LOF, OOF alarm conditions and result in
traffic loss.
Timing—The type of input clock service configured for the DS1 module. Set the
timing source to system if you are using the DS1 module to connect to the
network.
System—Configures the DS1 module to use the internal clock as the timing
source.
Loop—Configures the DS1 module to use the input port Rx clock as the timing
source; timing is received from the service “loop.” Select Loop if the DS1 UNI
module is used for the network/carrier service termination, in which case the
carrier (the service “loop”) typically provides the timing source.
Gain Limit (DS1 only)—Setting for the receive signal level: 26 or 36 dB.
Inband Lpbk (DS1 only)—Inband loopback. Enables the inband loop-up or
loop-down code: loop-up (enabled) or loop-down (disabled).
AFA—Enables (yes) or disables (no) Automatic Frequency Adjustment. AFA
monitors the error rate detected by the CRC (cyclic redundancy check)
error-checking scheme of each of the DS1/E1 links (ports). It automatically disables
and re-enables a port when the error rate on that port is at a set level for a set
time.
Activation Rate—The CRC (cyclic redundancy check) BER (bit error rate) at which
AFA takes a link out of service based on the Activation Min.: 10-4, 10-5, 10-6, 10-7.
For further details about setting this parameter, see “Activation/Deactivation Bit
Error Rates” below. This parameter appears only when AFA is enabled.
Activation Min.—The period during which AFA monitors the link condition prior
to taking it out of service, in minutes: 1 to 15. This parameter appears only when
AFA is enabled.
Deactivation Rate—The CRC (cyclic redundancy check) BER (bit error rate) at
which AFA puts a link in service based on the Deactivation Min.: 10-4, 10-5, 10-6,
10-7. For further details about setting this parameter, see “Activation/Deactivation
Bit Error Rates” below. This parameter appears only when AFA is enabled.
Deactivation Min.—The period during which AFA monitors the link condition
prior to putting it in service, in minutes: 1 to 15. This parameter appears only
when AFA is enabled.
Activation/Deactivation Bit Error Rates
Table 33 translates bit errors rates into the total number of errors for various time
periods. Use this table as a reference when you are selecting activation and
deactivation bit error rates for the AFA feature.
138
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Table 33 Bit Error Rates Translated into Total Number of Errors
Bit
Error
Rate
(BER)
Total Errors Total Errors Total Errors
in 5
in 15
Total Errors Total Errors in 2
Minutes
Minutes
in 1 second in 1 Minute Minutes
10-4
15
900
1800
4500
13500
10-5
1.5
90
180
450
1350
10-6
0.15
9
18
45
135
10-7
0.015
1
2
5
13
Group—The number of the group to which the ports belong.
Admin. Status—Administrative status: Out of Service or In Service.
Operation Status—Operation status: Response or No Response.
5 Select [13] Previous Menu to return to the DSI UNI Configuration menu.
6 Repeat steps 4 and 5 for any other DS1 or E1 ports that you want to configure.
Configuring UNI and
IMA Groups
You can map two to eight DS11/E1 ports into an IMA group, thereby creating a
logical, inverse-multiplexed, high-speed link. The PathBuilder S700 also supports
UNI groups.
Adding UNI Groups
To set up a UNI group, follow these steps:
1 From the Configuration Management menu, shown earlier in Figure 80, select
[1] Manage Card.
2 From the List Card menu, shown earlier in Figure 81, select the number
corresponding to the slot in which the DS1 UNI or E1 UNI card is installed to open
the DS1 or E1 UNI Configuration menu, shown earlier in Figure 95.
3 From the DS1 or E1 UNI Configuration menu, select [3] Group Configuration to
display the Group menu, shown in Figure 99.
Configuring DS1 UNI or E1 UNI with IMA Modules
Figure 99 Group Menu
4 Select [2] Add Group to display the Add Group menu, shown in Figure 100.
Figure 100 Add Group Menu (Selecting Group Type)
5 Enter [1] UNI. The Add Group menu appears as shown in Figure 101.
139
140
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Figure 101 Add Group Menu (Adding UNI Group)
6 Select [1] Set Admin. Port(s). The following prompt appears at the bottom of the
screen:
Enter Admin Port(s) (1..4):
7 Enter the port number(s) of the T1/E1 port(s) you want to include in the UNI
group.
8 Select [2] Set Admin. Status and enter [2] to put the group in service.
9 Select [3] Set Number of VPI for VCC and specify the number of distinct VPIs that
can be used for VCCs on this card: 1-256. Any VPIs not currently in use by VCCs
are available for VPCs.
10 Select [3] Previous Menu.
11 If desired, repeat steps 5-8 to set up a additional UNI groups and put them into
service.
Adding IMA Groups
To set up an IMA group, follow these steps:
1 From the Configuration Management menu, select [1] Manage Card to display the
List Card menu, shown earlier in Figure 81.
2 From the List Card menu, select the number corresponding to the slot in which the
DS1 UNI or E1 UNI card is installed to display the DS1 UNI or E1 UNI Configuration
menu, shown earlier in Figure 95.
3 Select [3] Group Configuration to display the Group menu, shown earlier in
Figure 99.
4 Select [2] Add Group to display the Add Group menu, shown earlier in Figure 100.
5 Enter [2] IMA. The Add Group menu appears as shown in Figure 102.
Configuring DS1 UNI or E1 UNI with IMA Modules
141
Figure 102 Add Group Menu (Adding IMA Group)
6 Select [1] Set Admin. Port(s). The following prompt appears:
Enter Admin Port(s) (1..4):
7 Enter the port numbers for the DS1/E1 ports you want to include in the group.
You can use a hyphen to indicate a range of ports. For example, to include ports
1-3 in a group you could enter 1-3.
8 Set the following parameters to configure the IMA group:
Frame Length—The frame length: 32, 64, 128, 256.
Max. Link Delay—The maximum link differential delay allowed in the group: 0 to
70 msec for DS1, 0 to 56 msec for E1
Min Tx/Rx Startup Ports—The minimum number of ports in the group that must
be operational in order for the group to come up: 1 to n, where n is the number of
ports in the group.
Min Tx/Rx Oper. Ports—The minimum number of ports in the group that must
be operational in order for the group to come up and be operational: 1 to n,
where n is the number of ports in the group.
IMA ID—A user-selected number to identify the IMA group.
Test Link—The port number of the link that is to perform the test procedure.
Test Pattern—The pattern to be looped back in the test procedure: 0-254.
Test Procedure—Enables or disables the test procedure. When the test procedure
is enabled, the test pattern is sent out on the designated test link and then looped
back on the other links in the group.
Admin Status—The administrative status of the group: In Service or Out of
Service.
Number of VPI for VCC—The number of distinct VPIs that can be used for VCCs
on this card: 1-32. Any VPIs not currently in use by VCCs are available for VPCs.
9 Select [12] Previous Menu.
10 If desired, repeat steps 5-8 to set up another IMA group.
142
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Viewing and Modifying IMA and UNI Groups
Once you have added a group, you use the List/Modify Group menu to view and
modify group configuration parameters.
To view and/or modify an existing group, follow these steps:
1 From the Group menu, shown earlier in Figure 99, select [1] List/Modify Group to
open the List/Modify Group Selection menu. Figure 103 shows the E1 List/Modify
Group Selection menu. The DS1 menu is the same. The List/Modify Group
Selection menu lists the existing groups, by group number.
Figure 103 List/Modify Group Selection Menu
2 Enter the number corresponding to the group you want to view or modify to
display the Group Configuration Options menu for that group. Figure 104 shows
the E1 UNI Group Configuration Options menu. The DS1 UNI menu is the same.
The options on this menu allow you to access other menus from which you can
configure group parameters or virtual interfaces.
Figure 104 Group Configuration Options Menu
Configuring DS1 UNI or E1 UNI with IMA Modules
143
3 Select [1] Group Configuration to display the List/Modify Group menu. Figure 105
shows the E1 UNI List/Modify Group menu. The DS1 UNI menu is the same.
Figure 105 UNI List/Modify Group
4 If the Admin. Status of the group is In Service, select [10] Set Admin. Status and
enter [1] to take the group out of service.
You must take the group out of service before you can modify it.
5 Change any of the group parameters as desired. For parameter definitions, see
“Adding IMA Groups” earlier in this chapter.
Configuring Virtual Interfaces for IMA Groups
To configure virtual interfaces for IMA groups, follow these steps:
1 From the Group menu, shown earlier in Figure 99, select [1] List/Modify Group to
open the List/Modify Group Selection menu, shown earlier in Figure 103.
2 Enter the number corresponding to the group for which you want to configure
virtual interfaces to display the Group Configuration Options menu for that group.
3 From the Group Configuration Options menu, shown earlier in Figure 104, select
[2] Virtual Interfaces to open the Virtual Interface Configuration menu. This menu
is the same as the MCPU Virtual Interfaces Configuration menu, shown earlier in
Figure 84.
4 Configure virtual interfaces as described under “Configuring Virtual Interfaces”
earlier in this chapter. You configure virtual interfaces for IMA groups in the same
way that you configure virtual interfaces for the MCPU card.
Deleting IMA and UNI Groups
To delete an existing IMA or UNI group, follow these steps:
1 From the List Card menu, shown earlier in Figure 81, select the number
corresponding to the slot in which the DS1 UNI or E1 UNI card is installed to
display the DS1 UNI or E1 UNI. Configuration menu, shown earlier in Figure 95.
2 Select [3] Group Configuration to display the Group menu, shown earlier in
Figure 99.
144
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
3 From the Group menu, select [3] Delete Group. The Delete Group Selection menu
appears, as shown in Figure 106.
Figure 106 Delete Group Selection Menu
4 Enter the number corresponding to the group you want to delete to open the
Delete Group menu. Figure 107 shows a representative Delete Group menu.
CAUTION: When you delete a group, you also delete all virtual circuits using that
group.
Figure 107 Delete Group Menu
5 Enter y in response to the warning/confirmation prompt to delete the group.
Configuring DS1 UNI or E1 UNI with IMA Modules
Viewing IMA Link Status
145
To view IMA Link Status for a selected DS1 or E1 port, follow these steps:
1 From the List Card menu, shown earlier in Figure 81, select the number
corresponding to the slot in which the DS1 UNI or E1 UNI card is installed to open
the UNI Configuration menu, shown earlier in Figure 95.
2 Select [2] IMA Link Status to open the IMA Link Status Selection menu, shown in
Figure 108. The IMA Link Status Selection menu lists only the ports that are
members of an IMA group.
Figure 108 IMA Link Status Selection Menu
3 Enter the number corresponding to the port for which you want to view IMA link
status. The IMA Link Status screen for that port appears, as shown in Figure 109.
Figure 109 IMA Link Status Screen
146
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
The IMA Link Status screen lists the following information pertaining to the IMA
status of an individual link in an IMA group.
NE Tx State—Near-end transmit state in the interworking link state machine.
Table 34 lists the possible link states.
NE Rx State—Near-end transmit state in the interworking link state machine.
Table 34 lists the possible link states.
FE Tx State—Far-end transmit state in the interworking link state machine.
Table 34 lists the possible link states.
FE Rx State—Far-end transmit state in the interworking link state machine.
Table 34 lists the possible link states.
.
Table 34 Possible IMA Link States
State
Tx Condition
Rx Condition
not in group
This link is not part of the IMA
group.
This link is not part of the IMA
group.
unusable
blocked
This is caused by LOS, which
This is caused by AFA,
would result in back clock from excessive delay, or mismatched
the framer if the port is in
protocol.
looped timing.
usable
This link is ready to pass data.
This link is ready to pass data.
active
This link is passing data.
This link is passing data.
FE Rx Failure—Far-end Rx failure status in the interworking link state machine.
Table 35 lists the possible IMA link failure status conditions.
NE Rx Failure—Near-end Rx failure status in the interworking link state machine.
Table 35 lists the possible IMA link failure status conditions.
Table 35 Possible IMA Link Failure Status Conditions
Failure
Description
link failure
This is caused by LOS, AIS, OOF, or LCD
LIF failure
This is caused by LIF
LODS failure
This is caused by LODS.
Misconnected
This is caused by bad IMA ID, bad link ID, or bad SCCI.
blocked
This is caused by AFA, excessive delay, or mismatched
protocol.
fault
This is caused by bad M value, bad symmetry, bad offset,
or duplicate link ID.
far end Tx link
unusable
This is caused by the far end reporting Tx unusable in the
ICP cells.
far end Rx link
unusable
This is caused by the far end reporting Rx unusable in the
ICP cells.
no failure
The link has no failure.
Tx LID—Transmit logical link ID: 0-31. This number reflects the local IMA ID.
Rx LID—Receive logical link ID: 0-31. This number reflects the remote IMA ID.
Operation LInk Delay—The differential link delay referenced to the fastest link in
the same group.
Configuring DS1 UNI or E1 UNI with IMA Modules
147
Rx Test Pattern—The received test pattern received: 0-254; 255 indicates that no
pattern has been received.
Test Procedure—The status of the test procedure: disabled, operating, or link
failed.
Viewing IMA Group
Status
To view IMA status for a selected group, follow these steps:
1 From the List Card menu, shown earlier in Figure 81, select the number
corresponding to the slot in which the DS1 UNI or E1 UNI card is installed to open
the UNI Configuration menu, shown earlier in Figure 95.
2 Select [4] IMA Group Status to open the IMA Group Status Selection menu, shown
in Figure 110. The IMA Group Status Selection menu lists existing IMA groups.
Figure 110 Group Status Selection Menu
3 Enter the number corresponding to the group for which you want to view IMA
status. The IMA Group Status screen for that group appears, as shown in
Figure 111.
148
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Figure 111 IMA Group Status Screen
The IMA Group Status screen lists the following information pertaining to the IMA
status of the group as a whole.
Operation Port(s)—The port numbers of the active links in the group.
NE State—The status of the near end group state machine: not configured,
startup, startupAck, unsupported M, incompatible symmetry, other config abort,
insufficient links, blocked, or operational.
FE State—The status of the far end group state machine: not configured, startup,
startupAck, unsupported M, incompatible symmetry, other config abort,
insufficient links, blocked, or operational.
Failure Status—Failure status of the near end interworking group state machine.
Table 36 lists the possible IMA group failure status conditions.
Configuring DS1 UNI or E1 UNI with IMA Modules
149
Table 36 Possible IMA Group Failure Status Conditions
Failure
Description
Near End Asymmetric
Near end rejected asymmetrical configuration or operation
chosen by the far end.
Far End Invalid M
Far end rejected the M value chosen by the user on the
near end.
Other Failures
The near end group detected multiple IMA ID, multiple M,
or multiple symmetry, or the group has duplicated IMA ID,
or the far end reported configuration abort without any
reason.
Near End Insufficient
Links
This is a normal transitional state when the near end group
is coming up. If it persists, it indicates that the group
indeed does not have enough links to come up and pass
data.
Far End Insufficient
Links
This is a normal transitional state when the far end group
is coming up. If it persists, it indicates that the group
indeed does not have enough links to come up and pass
data.
Near End Blocked
The near end group cannot pass data due to LODS.
Far End Blocked
The far end group has enough links, but cannot pass data
for some other reason.
Near End Startup
This is a normal transitional state when the near end group
is coming up.
Far End Startup
This is a normal transitional state when the far end group
is coming up.
No Failure
The group has no failure.
FE Tx Clocking—Far-end transmit clocking mode: common or independent.
Tx Timing Ref. Link—The near end transmitting timing reference port for cell
clock recovery: 1 to N.
Rx Timing Ref. Link—The near end received timing reference port for cell clock
recovery: 1 to N.
Rx IMA ID—The IMA receive group ID: 0-255. This number reflects the remote
IMA ID.
NE State Last Changed—The date and time at which the near-end state last
changed.
Rx Framer Length—Receive M value: 32, 64, 128, or 256. The frame length of
the first link that can communicate with the far end is chosen as the frame length
of the far end group.
Least Delay Link—The port number of the fastest link in the group.
Oper. LInk Delay—Operational link delay; the actual value of the link differential
delay: 0-70 msec for T1, 0-50 msec for E1.
Tx Avable. Cell Rate (cps)—The available cell rate for active Tx links in this
group: 0-28,728 cps for DS1, M=128; 0-35,920 cps for E1, M=128. The available
cell rate indicates how much bandwidth can be carried across the group. It varies,
depending on how many links in the group are actually working.
150
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Rx Avable Cell Rate (cps)—The available cell rate for active Rx links in this group:
0-28,728 cps for DS1, M=128; 0-35,920 cps for E1, M=128. The available cell rate
indicates how much bandwidth can be carried across the group. It varies,
depending on how many links in the group are actually working.
# Tx Configured Links—The number of configured transmit links.
# Rx Configured Links—The number of configured receive links.
#Tx Active links—The number of active transmit links.
#Rx Active links—The number of active receive links.
Configuring DS1 UNI or
E1 UNI Cards
The only type of configuration you can perform on a DS1 UNI or E1 UNI card is to
put it in service or out of service. To put a DS1/E1 UNI card in service or out of
service, follow these steps:
1 From the List Card menu, shown earlier in Figure 81, select the number
corresponding to the slot in which the DS1 UNI or E1 UNI card is installed to
display the DS1 UNI or E1 UNI Configuration menu, shown earlier in Figure 95.
2 From the DS1 UNI or E1 UNI Configuration menu, select [5] Card Information to
display the Card Configuration menu. Figure 112 shows the E1 UNI Card
Configuration menu. The DS1 UNI Card Configuration menu is the same.
3 Select [1] Set Admin Service and enter [2] to put the card in service or [1] to take it
out of service.
Figure 112 E1 UNI Card Configuration Menu
In addition to the current DS1/E1 card configuration, the DS1/E1 UNI Card
Configuration menu lists the following group-related information:
Operation Group—The active IMA groups in the card.
Num. of IMA Group(s)—The number of IMA groups created (but not necessarily
active) on the card.
Configuring Ethernet Modules
Configuring Ethernet
Modules
Configuring Ethernet
Ports, Cards, Shapers
and Virtual Interfaces
151
Configuring an Ethernet module involves the following tasks:
n
Configuring the Ethernet ports, card, shapers, and virtual interfaces
n
Configuring the bridge
To configure Ethernet ports, card, shapers, and virtual interfaces, follow these
steps:
1 From the List Card menu, shown earlier in Figure 81, select the slot number
corresponding to the Ethernet module to display the Ethernet Configuration
menu, shown in Figure 113.
Figure 113 Ethernet Configuration Menu
2 Set the administrative status of the Ethernet ports (put them into service and take
them out of service).
a From the Ethernet Configuration menu, select the option corresponding to the
Ethernet port you want to configure to display the Ethernet Port Configuration
menu for that port. Figure 114 shows a representative Ethernet Port
Configuration menu.
152
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Figure 114 Ethernet Port Configuration Menu
b Select [1] Set Admin. Status and enter [2] to put the Ethernet port into service
or [1] to take it out of service.
c Repeat steps a and b, selecting [2] Port 2 in step a, to set the administrative
status for Ethernet port #2.
d Select [2] Previous Menu to return to the Ethernet Configuration menu.
3 Set the administrative status of the Ethernet card (put it into service or take it out
of service).
a From the Ethernet Configuration menu, select [3] Card Information to display
the Ethernet Card Configuration menu, shown in Figure 115.
Figure 115 Ethernet Card Configuration Menu
b Select [1] Set Admin. Status and enter 2 to put the Ethernet card into service
or 1 to take it out of service.
c Select [2] Previous Menu to return to the Ethernet Configuration menu.
Configuring Ethernet Modules
153
4 Configure input shapers for the Ethernet card.
a From the Ethernet Configuration menu, select [4] Shaper Configuration to
display the Ethernet Shapers screen. This screen is the same as the MCPU Input
Shapers screen, shown earlier in this chapter in Figure 88.
b To enter a new shaper value, use the arrow keys on your keyboard to move to
the cell in the shaper table that you want to change.
You can set three input shaper parameters for the Ethernet card:
n
Peak Cell Rate (PCR)
n
Sustained Cell Rate (SCR)
n
Maximum Burst Size (MBS)
For detailed instructions about configuring input shapers, see “Configuring
Input Shapers” earlier in this chapter.
c Press [Esc] to return to the Ethernet Configuration menu.
5 Configure virtual interfaces for the Ethernet card.
a From the Ethernet Configuration menu, select [5] Virtual Interfaces to open the
Virtual Interfaces Configuration menu. This menu is the same as the MCPU
Virtual Interfaces Configuration menu, shown earlier in this chapter, in
Figure 84.
b Configure virtual interfaces as described under “Configuring Virtual Interfaces”
earlier in this chapter. You configure virtual interfaces for the Ethernet card in
the same way that you configure virtual interfaces for the MCPU card.
Configuring the Bridge
All of the virtual channels assigned to a particular slot and port form a network
bridge. In order to enable the Ethernet port to operate, you must configure the
bridge with the required user-filtering options and an aging timer value.
To configure the bridge, follow these steps:
1 From the Configuration Management menu, shown earlier in Figure 80, select
[3] Manage Bridge to display the Manage Bridge menu, shown in Figure 116.
Figure 116 Manage Bridge Menu
154
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
2 From the Manage Bridge menu, select [1] Bridge Configuration to display the
Bridge Configuration menu, shown in Figure 117. The current aging timer setting
is displayed below the menu title (3 minutes in the sample menu shown in the
figure).
Figure 117 Bridge Configuration Menu
3 Select [1] Set Aging Timer. The following prompt appears at the bottom of the
screen:
Enter Aging Timer (minute):
4 Enter the desired timer interval, in minutes.
5 Select [2] Previous Menu to return to the Manage Bridge menu.
6 From the Manage Bridge menu, select the number corresponding to the slot and
port combination for which you want to configure a bridge. The Bridge Menu for
the selected slot/port combination appears. Figure 118 shows a representative
Bridge menu.
Figure 118 Bridge Menu
Configuring Ethernet Modules
155
From the Bridge menu, you can:
n
Configure source protocol filtering, source address filtering, and destination
address filtering.
n
Display the forwarding table for the bridge.
n
Construct a static table (a table of source/destination pairs which you do not
want to be aged out of the forwarding table) for the bridge.
n
View and clear bridge statistics.
The following subsections tell you how to perform these operations.
Configuring Source Protocol Filtering
Source protocol filtering allows the bridge to filter out packets with certain
protocols. You can use this type of filtering to prevent certain type of protocol
traffic from being bridged across the ATM network. Protocols such as IPX and
Appletalk, for example, can be filtered on the sending end. This is useful in
restricting your local Novell network or Appletalk data traffic from being
transmitted on long distance ATM links, thereby saving bandwidth and providing
security.
To configure source protocol filtering, follow these steps:
1 From the Bridge menu, select [2] Source Protocol Filtering to display the Source
Protocol Filter menu, shown in Figure 119.
Figure 119 Source Protocol Filter Menu
The current statuses of the source protocol filters are listed at the top of the menu.
Yes indicates that packets with that protocol will be rejected. No indicates that
packets with that protocol will be transmitted across the bridge.
2 Change the filter settings as desired by entering the number corresponding to the
filter you want to set and responding to the prompt that appears at the bottom of
the screen. The list at the top of the menu is updated to reflect your change.
156
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
For example, if you want to configure an IP filter, select [1] Set Filter IP. The
following prompt appears at the bottom of the screen:
Enter Filter IP (1=No, 2=Yes):
Enter 2 to configure an IP filter; the bridge will reject packets with IP (Internet
Protocol).
3 Select [3] Previous Menu to return to the Bridge menu.
4 Select [1] Setup to display the Bridge Setup menu, shown in Figure 120. This menu
allows you to enable or disable the filters you have configured.
Figure 120 Bridge Setup Menu
5 Select [2] Set Source Protocol Filter. The following prompt appears at the bottom
of the screen:
Enter Source Protocol Filter (1=Disable, 2=Enable)
6 Enter 2 to enable the source protocol filter.
Configuring Source Address Filtering
Source address filtering allows the bridge to prevent packets containing a specific
source address from traversing the bridge. You can use source address filtering to
prevent some stations from transmitting on the ATM WAN link. This type of
filtering is useful for preventing specific stations in a common protocol group on
the Ethernet LAN from transmitting bursty and useless network data across the
bridge and onto the WAN.
Configuring Ethernet Modules
157
To configure source address filtering, follow these steps:
1 From the Bridge menu, select [3] Source Address Filtering to display the Source
Address Filter menu, shown in Figure 121.
Figure 121 Source Address Filter Menu
2 Select [2] Add Source Filter Address. The Add Source Address Filter screen appears.
This screen displays the following prompt:
Enter MAC Address (XX:XX:XX:XX:XX:XX or <CR>):
3 Enter the MAC address of the station from which you do not want packets to
traverse the bridge. After you make your entry, you are returned to the Source
Address Filter menu.
4 Repeat steps 2 and 3, as desired, to add more addresses to the source filter list.
n
To view the current list, select [1] List Source Filter Address from the Source
Filter Address menu.
n
To change an address in the list, delete the incorrect address and add the
correct address.
n
To delete an address from the list, select [3] Delete Source Filter Address from
the Source Filter Address menu and enter the number corresponding to the
address you want to delete. Then enter y at the confirmation prompt to
delete the selected address.
5 Select [4] Previous Menu to return to the Bridge menu
6 Select [1] Setup to display the Bridge Setup menu, shown earlier in Figure 120.
This menu allows you to enable or disable the filters you have configured.
7 Select [3] Set Source Address Filter. The following prompt appears at the bottom
of the screen:
Enter Source Address Filter (1=Disable, 2=Enable)
8 Enter 2 to enable the source address filter.
158
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Configuring Destination Address Filtering
Destination address filtering prevents LAN packets with destination addresses
specified in the filter from being sent to the WAN. You can use destination address
filtering to prevent some stations from receiving data from the ATM WAN link. For
example, you can save network-traffic-sensitive stations (such as local file servers
and CAD servers) from unnecessary data coming from the WAN.
To configure destination address filtering, follow these steps:
1 From the Bridge menu, select [4] Destination Address Filtering to display the
Destination Address Filter menu, shown in Figure 122.
Figure 122 Destination Address Filter Menu
2 Select [2] Add Destination Filter Address. The Add Destination Address Filter
screen appears. This screen displays the following prompt:
Enter MAC Address (XX:XX:XX:XX:XX:XX or <CR>):
3 Enter the MAC address of the destination to which you do not want packets to be
sent across the bridge. After you make your entry, you are returned to the Source
Address Filter menu.
4 Repeat steps 2 and 3, as desired, to add more addresses to the destination filter
list.
n
To view the current list, select [1] List Destination Filter Address from the
Destination Filter Address menu.
n
To change an address in the list, delete the incorrect address and add the
correct address.
n
To delete an address from the list, select [3] Delete Destination Filter Address
from the Destination Filter Address menu and enter the number corresponding
to the address you want to delete. Then enter [2] at the confirmation prompt
to delete the selected address.
5 Select [4] Previous Menu to return to the Bridge menu
6 Select [1] Setup to display the Bridge Setup menu, shown earlier in Figure 120.
This menu allows you to enable or disable the filters you have configured.
Configuring Ethernet Modules
159
7 Select [4] Set Destination Address Filter. The following prompt appears at the
bottom of the screen:
Enter Destination Address Filter (1=Disable, 2=Enable)
8 Enter 2 to enable the destination address filter.
Viewing the List Forwarding Table
The List Forwarding Table is a current forwarding table for the bridge. To display
this table, select [5] Forwarding Table from the Bridge menu. Figure 123 shows a
representative List Forwarding Table.
Figure 123 List Forwarding Table
The List Forwarding Table identifies the port on which a certain MAC address is
located. This can be an Ethernet port or an ATM VC. Using the information in the
List Forwarding table, the bridge knows where to send a MAC address when it
receives one. If the Ethernet port receives a packet, and the destination MAC
address is not in the List Forwarding table, the port broadcasts the packet—sends
it to all VCs associated with that port.
The List Forwarding Table includes the following columns of information:
MAC Address—The destination MAC address.
Disp.—Disposition:
Bridge—The default disposition.
Flood—Flood the frame on all available VCs.
Filter—Drop this frame.
Accept—Accept this frame.
Static—Destination MAC address is in Bridge Static Table.
SRC_Address_Filtering—User-configured source address filter.
DEST_Address_Filtering—User-configured destination address filter.
160
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Location—One of the following two types of entries:
ENET <slot/port>—Ethernet slot and port number. This type of entry is
displayed when the MAC address is reached through that port.
VC <non-Ethernet side of VC data>—The card type, slot and port number,
and other virtual circuit parameters, such as DLCI number, for the non-Ethernet
side of the virtual circuit. This type of entry is displayed when the MAC address
is reached through that virtual circuit.
Age—The age of the station address entry in the List Forwarding Table. You can
set this parameter to Permanent or a specified number of seconds. The system
uses the Age parameter to delete station address entries when they have had no
traffic for the specified period of time.
Constructing the Bridge Static Table
The Bridge Static Table is a list of destination MAC addresses that you want to
maintain in the List Forwarding Table and do not want to be purged by the aging
timer. The Disp. column for these addresses in the Forwarding Table reads Static to
indicate that they will remain in the Forwarding Table until they are manually
deleted from the Static Table.
To construct the Bridge Static Table, follow these steps:
1 From the Bridge menu, select [6] Static Table to display the Bridge Static Table
menu, shown in Figure 124. From this menu, you can view the Static table and
add and delete entries from it.
Figure 124 Bridge Static Table Menu
2 Select [2] Add MAC Address. The Add MAC address screen appears. This screen
displays the following prompt:
Enter MAC Address (XX:XX:XX:XX:XX:XX or <CR>):
3 Enter the destination MAC address that you want to add to the Bridge Static
Table. This address will not be purged when the List Forwarding Table is aged. The
following prompt appears:
Attach MAC address to an existing VCC? (y/n [n]):
Configuring Ethernet Modules
161
4 Enter y or n.
n
If you enter y, a screen appears with a list of existing virtual circuits. Enter the
number corresponding to the virtual circuit to which you want to attach the
destination MAC address.
n
If you enter n, the MAC address will be associated with this Ethernet port.
5 Repeat steps 2-4, as desired, to add more addresses to the Bridge Static Table.
n
To view the current Bridge Static Table, select [1] List Static Table from the
Bridge Static Table menu. The Bridge Static Table includes the following
columns of information:
MAC Address—The destination MAC address.
Location—One of the following two types of entries:
ENET <slot/port>—Ethernet slot and port number. This type of entry is
displayed when the MAC address is reached through that port.
VC <non-Ethernet side of VC data>—The card type, slot and port
number, and other virtual circuit parameters, such as DLCI number, for the
non-Ethernet side of the virtual circuit. This type of entry is displayed when
the MAC address is reached through that virtual circuit.
n
To delete an address from the table, select [3] Delete MAC Address from Bridge
Static Table menu and enter the number corresponding to the address you
want to delete. Then enter y at the confirmation prompt to delete the
selected address from the Bridge Static Table.
Enabling and Disabling the Spanning Tree
Spanning Tree (IEEE 802.1d) is a technique that detects loops in a network and
logically blocks the redundant paths, ensuring that only one route exists between
any two LANs. It eliminates the duplication of packets and provides fault tolerance
for resilient networks.
To enable or disable the Spanning Tree, follow these steps:
1 From the Configuration Management menu, select [3] Manage Bridge to display
the Manage Bridge menu, shown earlier in Figure 116.
2 From the Manage Bridge menu, select the number corresponding to the slot and
port combination for which you want to enable or disable the Spanning Tree. The
Bridge Menu for the selected slot/port combination appears, as shown earlier in
Figure 118.
3 Select [1] Setup to display the Bridge Setup menu, shown earlier in Figure 120.
4 Select [1] Set Spanning Tree Operation. The following prompt appears:
Enter Spanning Tree Operation Status (1=Disabled, 2=Enabled):
5 Enter 1 or 2 to disable or enable the Spanning Tree.
For further information on Spanning Tree and how it operates, see “Spanning
Tree” in Chapter 4.
Configuring IP Over ATM
In addition to the standard bridging configuration described in the previous
section, you can also configure IP over ATM for either of the PathBuilder S700’s
Ethernet ports. IP over ATM is a method to pass IP traffic across an ATM network;
it follows RFC 1577.
162
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
To configure IP over ATM for an Ethernet port, follow these steps:
1 Access the IP over ATM menu for the Ethernet port for which you want to
configure IP over ATM.
a From the main menu, select [2] Configuration Management.
b Select [4] Manage IP over ATM. The Manage IP over ATM port selection menu
appears, as shown in Figure 125.
Figure 125 IP over ATM Port Selection Menu
c Enter the number corresponding to the Ethernet port for which you want to
configure IP over ATM. The IP over ATM menu for the selected port appears, as
shown in Figure 126.
Figure 126 IP over ATM Menu
2 If desired, view the current IP over ATM configuration.
a select [1] View Setup. Figure 127 shows a representative IP over ATM Setup
screen.
Configuring Ethernet Modules
163
Figure 127 IP over ATM Setup Screen
b Press any key to return to the IP over ATM menu.
3 View the virtual circuit that is currently specified to pass the IP traffic over the ATM
network.
a Select [4] Specify Virtual Circuit to display the Specify Virtual Circuit menu,
shown in Figure 128. This menu lists the virtual circuit that is currently selected
to pass the IP traffic over the ATM network.
Figure 128 Specify Virtual Circuit Menu
b Accept or delete the current virtual circuit (the one displayed on the Specify
Virtual Circuit menu).
n
n
If you want to use the current virtual circuit, press any key other than [s] or
[d] to return to the previous menu and skip to step 5.
If you want to specify a new virtual circuit, press [d] to delete the current
virtual circuit and continue to step 4.
164
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
4 Specify a new virtual circuit to pass the IP traffic over the ATM network (if desired).
a From the Specify Virtual Circuit menu, shown earlier in Figure 128, press [s] to
display a screen similar to the one shown in Figure 129. This screen lists the
existing virtual circuits connected to the selected Ethernet port.
Figure 129 Specify Virtual Circuit Selection Screen
b Enter the number corresponding to the virtual circuit you want to use to pass
the IP traffic over the ATM network. The circuit you select will now be listed on
the Specify Virtual Circuit menu.
5 Configure the parameters for the LAN and ATM routers that will pass the IP traffic
across the ATM network.
a Select [5] Configure LAN Router to display the IP over ATM LAN Router
Configuration menu, shown in Figure 130.
Figure 130 IP over ATM LAN Router Configuration Menu
Configuring Ethernet Modules
165
b Set the following parameters:
IP Address—The IP address of the LAN router that will pass the IP traffic across
the ATM network.
Subnet Mask—The subnet mask of the LAN router that will pass the IP traffic
across the ATM network.
c Select [3] Previous Menu to return to the IP over ATM menu.
d Select [6] Configure ATM Router to display the IP over ATM ATM Router
Configuration menu. This menu is the same as the IP over ATM LAN Router
Configuration menu, shown earlier in Figure 130, except that it displays and
allows you to set parameters for the ATM router rather than the LAN router.
e Set the IP Address and Subnet Mask for the ATM router.
f Select [3] Previous Menu to return to the IP over ATM menu.
6 Enable or disable IP over ATM.
a Select [2] Enable/Disable IP over ATM to display the IP over ATM Admin. Status
Change menu for IP over ATM status, shown in Figure 131.
Figure 131 IP over ATM Admin. Status Change Menu: for IP over ATM
b Select [1] Set IP over ATM Status. The following prompt appears:
Enter IP over ATM Status (1=Disabled, 2=Enabled):
c Enter 2 (to enable) or 1 (to disable) IP over ATM.
d Select [2] Previous menu to return to the IP over ATM menu.
7 Enable or disable Bridging.
a Select [3] Enable/Disable Bridging to display the IP over ATM Admin. Status
Change menu for Bridging Control status. This menu is the same as the IP over
ATM Admin. Status Change menu for IP over ATM status, except that it allows
you to enable or disable bridging rather than IP over ATM.
b Select [1] Set Bridging Control Status. The following prompt appears:
Enter Bridging Status (1=Disabled, 2=Enabled):
c Enter 2 (to enable) or 1 (to disable) bridging control.
166
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Configuring DSX-1
CBR or E1 CBR
Modules
The PathBuilder S700 supports both a DSX-1 CBR module and a E1 CBR module.
The configuration procedure is the same for both modules, but different
parameters are available on the port configuration menu.
Configuring a CBR module involves the following tasks:
n
Setting the administrative status of the card (putting it into service and taking it
out of service)
n
Configuring the ports
n
Configuring the virtual interfaces
The DSX-1/E1 CBR ports support a “lite” RS-366 template. This feature works as
follows:
n
From the CBR DSX/E1 Port Configuration menu, you set an Idle Timer value.
The CBR software starts an internal timer when no cell is being received. If the
amount of time you specify as the Idle Timer expires before another cell is
received, the software shuts off cell transmission and puts the virtual circuit
into a listening mode.
n
When you configure a virtual circuit for a DSX-1/E1 CBR port for which the Port
Mode is set to Struct Data, the Add Virtual Circuit screen includes a Mode
parameter. You can set the circuit Mode to Normal, RS366, or DBA.
For details about how to set to configure virtual circuits, see “Configuring Virtual
Circuits” later in this chapter.
n
n
n
If you set the Mode to Normal, the circuit is configured as a standard PVC
circuit and does not listen to video signals.
If you set the Mode to RS366, the circuit is put into an active listener mode;
it listens for video signals from premises devices.
If you set the Mode to DBA, the circuit is configured to dynamically reassign
the timeslot.
The CBR module supports two types of dynamic bandwidth allocation (DBA):
n
Structured voice DBA—Stored signaling bits are checked and bandwidth is
released when an on-hook (idle) condition is detected.
n
Structured data DBA—DSO payload bytes are checked and bandwidth is
released when an on-hook (idle) condition is detected.
For details about how DBA works, see “DS0 Signaling and Dynamic Bandwidth
Allocation” in Chapter 4. For details about configuring CBR virtual circuits for
DBA, see “Configuring CBR Virtual Circuits for DBA” later in this chapter.
Configuring DSX-1 CBR or E1 CBR Modules
167
To configure a DSX-1 CBR or E1 CBR module, follow these steps:
1 From the List Card menu, select the number corresponding to the slot in which the
CBR module is installed. The CBR Configuration Port/Card Selection menu
appears, as shown in Figure 132.
Figure 132 CBR Configuration Port/Card Selection Menu
2 Set the administrative status of the CBR card.
a Select [5] Card Configuration to display the CBR DSX or CBR E1 Card
Configuration menu. Figure 133 shows the CBR DSX Card Configuration
menu. The CBR E1 Card Configuration menu is similar.
Figure 133 CBR DSX Card Configuration Menu
b Select [2] Set Admin Status and enter 1 to take the card out of service or 2 to
put it into service.
c Select [2] Previous Menu to return to the CBR Configuration menu.
3 Configure the CBR ports.
168
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
a From the CBR Configuration menu, select the number corresponding to the
CBR port you want to configure to display the CBR DSX or CBR E1 Port
Configuration menu for that port. The options available on this menu vary,
depending whether the Port Mode is set to Unstructured, Structured Voice, or
Structured Data.
Figure 135 shows a CBR DSX Port Configuration menu for an Unstructured
port. shows a CBR DSX Port Configuration menu for a Structured Voice port.
shows a CBR DSX Port Configuration menu for a Structured Data port. The
CBR E1 Port Configuration menus are similar.
Figure 134 CBR DSX Port Configuration Menu (Unstructured Port
Figure 135 CBR DSX Port Configuration Menu (Structured Voice Port)
Configuring DSX-1 CBR or E1 CBR Modules
169
Figure 136 CBR DSX Port Configuration Menu (Structured Data Port)
b Set the following port configuration parameters, as desired.
DSO Channels are not configurable from the CBR Port Configuration menu. You
can assign DSO channels in structured voice or structured data mode only when
you add a CBR virtual circuit. See “CBR Module Virtual Circuit Parameters” later in
this chapter for details. All available DSO channels are automatically allocated in
unstructured mode.
LBO (DSX-1 CBR only)—Line Build Out. LBO refers to the signal
generation/regeneration of the distance between the PathBuilder S700 and the
next crossconnect of FOTs (Fiber Optic Terminal system), in feet: 1-100,
100-200, 200-300, 300-400, 400-500 or 500-600.
Line Code (DSX-1 CBR only)—The zero code suppression technique
configured to the DSX-1 CBR port. Set this parameter to match the service
provider or device connection line coding. The default is B8ZS. The Line Code
must match at local and remote ports.
AMI—Alternate mark inversion; a T1 (1.544 Mbps) carrier line coding
format whereby successive ones (marks) are alternately inverted.
B8ZS—Binary 8 Zero Substitution; a T1 (1.544Mbps) carrier line coding
format used to accommodate “ones density” for clear channel
transmission.
Port Mode—The type of service configured to the specified port:
Both Structured Data and Structured Voice modes allow end to end DSO
connectivity.
Structured Data—Structured service provides N x 64 kbit/second
capability, where N ranges between 1 and the maximum number of
available DSO channels. Structured data service passes traffic with signaling
information disabled—it provides for DSO midspan carrier access without
ABCD signaling bits terminating DS1 or E1 framing at the DSX-1 CBR or E1
CBR interface.
170
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Bandwidth usage will be more efficient if traffic from T1 with ISDN PRI and E1
with common channel signaling (CCS) is carried on ports configured as Structured
Data. This is because when a CBR port is configured as Structured Data, only DS0
payload bytes are carried in AAL1 cells. Therefore, an activated CBR virtual circuit
built on a port configured as Structured Data takes less bandwidth then a similar
one built on a port configured as Structured Voice.
Structured Voice—Structured service provides N x 56 kbit/second
capability, where N ranges between 1 and the maximum number of
available DSO channels. Structured voice service passes traffic with signaling
information enabled—it provides for DSO midspan carrier access with
ABCD signaling bits terminating DS1 or E1 framing at the DSX-1 CBR or E1
CBR interface.
Unstructured—Unstructured service provides DS1 or E1 frame tunneling; it
allows the application to utilize the entire available bandwidth at a bit rate
of 1.544 Mb/second. T1 framing is optional in this service mode.
Framing—The type of frame organization configured for the DS1 or E1 port
interface: D4 or ESF for the DSX-1 CBR module; G.704 for the E1 CBR module.
Set this parameter to match the service provider or device connection framing.
The Framing must match at local and remote ports.
CAUTION: A framing mismatch can cause LOF, OOF alarm conditions and result in
traffic loss.
TC Signaling Type (Structured Voice ports only)—This is the type of signaling
done between PBXs. This also sets the signaling type used for each of the
virtual circuits across this port. The values for TC Signaling are 1=PLAR, 2=E&M,
3=FXO-Loop Start, 4=FXS-Loop Start, 5=FXO-Ground Start, 6=FXS-Ground
Start, 7=R2(E1)
For PRI signaling, you must set the TC Signaling Type to PLAR.
TC1 Signaling Bits / TC2 Signaling Bits (Structured Voice ports only)—Trunk
condition 1 and trunk condition 2 signaling bits: onhook or offhook. The
default for TC1 Signaling Bits is onhook, while the default for TC2 Signaling is
offhook. The default values are usually suitable for PBX applications, but for
channel bank applications you should set TC2 Signaling Bits to onhook.
Timing—The type of input clock service configured for the port interface. The
default is System. The SRTS and Adaptive options are normally used for voice
applications—SRTS for unstructured voice applications and Adaptive for
unstructured voice or data applications.
System—Configures the port interface to use the internal clock as the
timing source.
Loop—Configures the port interface to use the input port Rx clock as the
timing source; timing is received from the service “loop.” Select Loop if the
T1 port is used for the network/carrier service termination, in which case the
carrier (the service “loop”) typically provides the timing source.
SRTS (Unstructured ports only)—Synchronous Residual Time Stamp; a
means to measure the service clock frequency against a network-wide
synchronization signal. SRTS measures input frequency against the master
network clock source and adjusts the line rate by sending residual time
stamps in the AAL1 header to the remote end.
Configuring DSX-1 CBR or E1 CBR Modules
171
Adaptive (Unstructured ports only)—A non-required network-wide
synchronization technique used to regenerate the input service clock.
Adaptive timing uses a buffer depth indicator at the receiver to adjust the
line rate: the fuller the buffer, the faster the line rate; the emptier the buffer,
the slower the line rate.
Figure 137 illustrates the SRTS and Adaptive timing options.
Figure 137 DSX-1 CBR Timing Options
Send Difference (-5 Hz)
DS1
Reference - 5 Hz
AAL Header
-5 Hz
Reference Check
Synchronous Residual Time Stamp (SRTS)
DS1
AAL 1
Buffer
Adaptive
Clock
> <
Depends
on Buffer
Idle Timer—The length of time with no cells present after which the CBR
software shuts off cell transmission and idles the other direction of the virtual
circuit: 5, 15, 30, 45, or 60 seconds. This parameter pertains only to CBR virtual
circuits on structured data ports for which the virtual circuit mode has been set
to RS366. For details about setting the mode for CBR virtual circuits, see “CBR
Module Virtual Circuit Parameters” later in this chapter.
DBA Bits Mask (Structured Data ports only)—Dynamic bandwidth allocation
bits mask; a numeric code, in the range 1-255, representing a mask that masks
off bits that are not a portion of the idle code. When a DSX-1/E1 CBR port is
configured as structured data, all virtual circuits in the port use a preselected
DBA Bits Mask. The decimal number that represents the DBA Bits Mask
corresponds to an internal 8-bit value. The default DBA Bits Mask is 127.
The DBA Bits Mask parameter is designed to accommodate situations in which the
PathBuilder S700 must communicate with equipment that uses non-standard
signalling patterns. In most cases you should leave this parameter set to its default
value.
CRC-4 (E1 CBR only)—Enables or disables Cyclic Redundancy Check 4 (CRC-4)
information. CRC-4 is a framing option that checks for errors in data. It is a
communication check for parity/framing and is used for performance
monitoring in E1 networks. CRC4 can be enabled only in structured and
multi-frame mode.
Admin Status—Administrative status: Out of Service or In Service.
172
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
c Return to the CBR Configuration menu.
d Repeat steps a and b for the other DSX-1 CBR or E1 CBR ports you want to
configure.
e Return to the CBR Configuration menu.
4 Configure virtual interfaces for the CBR card.
a From the CBR DSX or CBR E1 Configuration menu, select [6] Virtual Interfaces
to open the Virtual Interfaces Configuration menu. This menu is the same as
the MCPU Virtual Interfaces Configuration menu, shown earlier in this chapter,
in Figure 84.
b Configure virtual interfaces as described under “Configuring Virtual Interfaces”
earlier in this chapter. You configure virtual interfaces for the CBR card in the
same way that you configure virtual interfaces for the MCPU card.
Configuring
QSIM/HSIM/FAM
Modules
The PathBuilder S700 supports three frame relay modules: QSIM, HSIM, and FAM.
The configuration procedure is the same for all three modules, but different
parameters are available on the port configuration menu.
Configuring a QSIM, HSIM, or FAM involves the following tasks:
Configuring
QSIM/HSIM/FAM Ports
n
Configuring individual QSIM/HSIM/FAM ports
n
(For Frame Relay ports only) Configuring the QSIM/HSIM/FAM LMI (Local
Management Interface)
n
Configuring the QSIM/HSIM/FAM card and its input shapers and virtual
interfaces
To configure QSIM/HSIM/FAM ports, follow these steps:
1 From the List Card menu, select the number corresponding to the slot in which the
QSIM, HSIM, or FAM is installed. The QSIM, HSIM, or FAM Configuration menu
appears. Figure 138 shows the QSIM Configuration menu. The HSIM and FAM
menus are similar, except that the HSIM Configuration menu lists one port and the
FAM Configuration menu lists eight ports.
Configuring QSIM/HSIM/FAM Modules
173
Figure 138 QSIM Configuration Menu
2 Enter the number corresponding to the port you want to configure: 1-8 for the
QSIM; 1 for the HSIM; and 1-8 for the FAM. The QSIM, HSIM, or FAM Port
Configuration Selection menu appears. This menu provides options that allow you
to access menus for configuring port and (for Frame Relay ports) LMI (Local
Management Interface) parameters.
Figure 139 shows the QSIM Port Configuration Selection menu. The HSIM and
FAM menus are the same.
Figure 139 QSIM Port Configuration Selection Menu
3 Select [1] Port Configuration to display the Port Configuration menu for the
selected port. This menu displays the current serial port configuration and provides
options that allow you to change certain parameters. It varies depending on the
module (QSIM, HSIM, or FAM) and on whether the link type for the port is DXI,
HDLC/SDLC, or Frame Relay. Figure 140 shows a QSIM Port Configuration menu
for a Frame Relay port.
174
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Figure 140 QSIM Port Configuration Menu (DXI Port)
4 Change the following parameters, as desired:
Link Type—The input/output protocol for encapsulation and SAR to AALS
conversion.
DXI—ATM DXI Mode 1A
HDLC/SDLC—HDLC/SDLC frame pass-through
Frame Relay—Frame Relay Interworking (Frame Relay Forum Specification 5
and 8; modes 1 and 2).
DCE/DTE Mode (HSIM only)—The type of cable connected to the port: DCE or
DTE. This parameter is configurable for HSIMs only. The QSIM Port Configuration
menu displays the Cable Type as a read-only parameter derived automatically from
the type of cable connected to the module.
LBO (DS1 FAM only)—Line Build Out. LBO refers to the signal
generation/regeneration of the distance between the PathBuilder S700 and the
next crossconnect of FOTs (Fiber Optic Terminal system), in feet: 1-100, 100-200,
200-300, 300-400, 400-500 or 500-600.
Gain Limit (DS1 FAM only)—Setting for the receive signal level: 26 or 36 dB.
Line Code (DS1 FAM only)—The zero code suppression technique configured to
the FAM port. Set this parameter to match the service provider or device
connection line coding. The default is B8ZS. The Line Code must match at local
and remote ports.
Framing (DS1 FAM only)—The type of frame organization configured for the T1
port interface: D4 or ESF. Set this parameter to match the service provider or
device connection framing.
TDM Mode—n x 56k or n x 64k (clear channel), depending on the attached
equipment.
Timing (DS1 FAM only)—The type of input clock service configured for the DS1
FAM module. Set the timing source to system if you are using the DS1 FAM
module to connect to the network.
Configuring QSIM/HSIM/FAM Modules
175
System—Configures the DS1 FAM module to use the internal clock as the
timing source.
Loop—Configures the DS1 FAM module to use the input port Rx clock as the
timing source; timing is received from the service “loop.” Select Loop if the
DS1 UNI module is used for the network/carrier service termination, in which
case the carrier (the service “loop”) typically provides the timing source.
Terminal Timing Source—This parameter applies only when the attached cable
is DCE type cable. The setting for the Terminal Timing depends on the nature and
speed of the device application, but the typical configuration is Internal—the
PathBuilder S700 provides the clock for the device application. In any case, the
Terminal Timing Source setting for the PathBuilder S700 QSIM port must be the
opposite of that for the device. For example, if the Terminal Timing Source for the
router is set to Internal, then you must set the Terminal Timing Source for the
QSIM port to External.
Internal—The terminal receives clocking over DCE cable from the PathBuilder
S700. In other words, the PathBuilder S700 provides the clock to clock in the
data traffic from a router or other data device.
External—The terminal provides port clocking over the DCE cable to the
PathBuilder S700. In other words, The PathBuilder S700 accepts the clock for
data from the router or other data device.
Receive Timing Phase—Receive timing phase control. This parameter applies
only when the attached cable is DCE type cable. Depending on the speed of the
device application and the clock phases, particularly those of the return clock, you
may have to set Receive Timing Phase to Inverted (invert the clock) to ensure
correct clock and data phase. This option is used most often to correct for cable
length delays when Terminal Timing is set to Internal.
Normal—The receive timing from the remote endpoint (node) is normal
clocking.
Inverted—The receive timing from the remote endpoint (node) is inverted
clocking.
Data Rate—The data rate supported by the port: 64K, 128K, 256K, 512K, 1M,
6M, or 8M for the QSIM; 1.5M to 20M for the HSIM; 64K to 1.5M for the FAM.
This parameter applies only when the attached cable is DCE type cable. The Data
Rate setting also allows you to optimize the entire WAN ATM application by traffic
engineering your ATM access applications so as to maintain traffic flow across the
network.
Min. Flag Bytes—The minimum number of flag bytes required to distinguish a
frame. Select 1 (1 byte) or 2 (2 bytes). This parameter is valid only for HDLC/SDLC
data.
FCS Size—The number of bytes to use for FCS (Frame Check Sequence)
calculation for each frame. FRC is the CRC remainder sent at the end of a frame.
Select 1 (2 bytes) or 2 (4 bytes). This parameter is valid only for HDLC/SDLC data.
Admin Status—Administrative status: Out of Service or In Service.
176
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
QSIM/HSIM/FAM Performance at Small Frame Sizes
Note that this section pertains to QSIM, HSIM, and FAM performance with traffic
running at small frame sizes. Table 37, Table 38, and Table 39 describe the
configurations supported when the QSIM, HSIM, and FAM, respectively, are
running at small frame sizes.
In general, the maximum total throughput for the QSIM/HSIM/FAM is 31250
packets per second (pps). This is for full duplex traffic. Cases involving small size
frames requires high processing capacity when compared to that of large size
frames. With small size frames, test results show the PPS performance listed in the
following tables. Note that the maximum PPS is 31250.
Table 37 QSIM Performance at Small Frame Sizes
Frame
CLK rate Size
(Byte)
(MHz)
Max.Packet
Data Rate rate for
port
for port
(pps)
(Mbps)
packet rate
for card
number of (duplex)
active ports (pps)
2
64
2
3906
4
31248
4
64
4
7751
2
31004
64
4
1504
4
12032
128
4
635
4
5080
256
4
830
4
6640
64
8
9435
1
18870
64
8
1757
2
7028
64
8
977
3
5862
64
8
937
4
7496
128
8
215
4
1720
256
8
147
4
1176
8
Configuring QSIM/HSIM/FAM Modules
Table 38 HSIM Performance at Small Frame Sizes
Frame
CLK rate Size
(Byte)
(MHz)
max.packet
Data Rate rate for
port
for port
(pps)
(Mbps)
number of
loops
packet rate
for card
(duplex)
(pps)
1
64
1
1938
1
3876
64
1
1938
2
7752
64
1
1938
3
11628
64
1
1938
4
15504
64
1
1938
5
19380
128
1
985
1
1970
128
1
985
3
5910
128
1
985
5
9850
64
2
3875
1
7750
64
2
3875
3
23250
64
2
2247
5
22470
128
2
1968
3
11808
128
2
1348
5
13480
64
4
7751
1
15502
64
4
1367
3
8202
64
4
781
5
7810
128
4
3937
1
7874
128
4
3937
3
23622
128
4
1270
5
12700
64
8
9402
1
18804
64
8
605
5
6050
128
8
7462
1
14924
128
8
654
5
6540
2
4
8
177
178
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Table 39 FAM Performance at Small Frame Sizes
Max. Frames
per second on
Frame Size each port
64
128
Configuring the
QSIM/HSIM/FAM Local
Management Interface
Total Packets
on card
Active Ports (duplex)
Number of
2908
4
23264
2908
5
23264
2695
6
32340
1796
7
25144
1328
8
21248
1460
4
11680
1460
6
17520
1460
8
23360
To configure the QSIM/HSIM/FAM Local Management Interface (LMI), follow these
steps:
LMI configuration applies only to Frame Relay ports. The LMI Configuration menu
is not available if the QSIM, HSIM, or FAM port is configured as a DXI or
HDLC/SDLC port.
1 From the List Card menu, select the number corresponding to the slot in which the
QSIM, HSIM, or FAM is installed. The QSIM, HSIM, or FAM Configuration Port/Card
Selection menu appears, as shown earlier in Figure 138.
2 Select the number corresponding to the port you want to configure: 1-4 for the
QSIM; 1 for the HSIM; 1-8 for the FAM. The QSIM, HSIM, or FAM Port
Configuration Selection menu appears, as shown earlier in Figure 139.
3 Select [2] LMI Configuration to display the LMI Configuration menu for the
selected port. This menu displays the LMI configuration and provides options that
allow you to change certain parameters.
LMI configuration relates to the periodic polling that is performed between pairs
of Frame Relay devices to determine the status of PVC connections and to verify
the link integrity. This polling is done through a procedure known as Status
Enquiry. Two types are polling are performed: full status (FS) and link integrity
verification (LIV). Full status polling also includes link integrity verification.
Figure 141 shows the QSIM LMI Configuration menu. The HSIM and FAM LMI
Configuration menus are similar.
Configuring QSIM/HSIM/FAM Modules
179
Figure 141 QSIM LMI Configuration Menu
4 Change the following parameters, as desired:
Protocol—The protocol specified for the Status Enquiry procedure: none, q.933a,
or t1.617d.
Procedure—Specifies whether the PathBuilder S700 will be designated as the
user-side, the network-side, or bidirectional in the period polling performed
between frame relay devices.
n
If the PathBuilder S700 is configured as the network side unit, set the following
additional parameters:
Ntwk PV Timer (T392)—Network Polling Verification Timer. When the unit is
configured as the network side unit, the user-side unit sends the Status Enquiry
request. The Network Polling Verification acts on the user initiated-request and
checks whether or not it has any new information to report, based on the
specified timer.
Ntwk Error Threshold (N392) / Ntwk ME Count (N393)—These parameters
are related. The Ntwk ME (Monitored Event) Count is the threshold period that
you set to determine a service-affecting condition. The unit monitors
events—receipt STATUS ENQUIRY messages or expiration of polling timers—for
the number of seconds (3..10) that you specify. Within this specified Ntwk ME
Count period, if an error occurs within the number of seconds that you specify
as the Ntwk Error Threshold (3..10), the system declares an error.
n
If the PathBuilder S700 is configured as the user side unit, set the following
additional parameters:
User LIV Polling Timer (T391)—The time interval (in seconds) at which Status
Enquiry occurs for link integrity verification (LIV) polling: 5..180.
Set this parameter at a higher value than the Network PV Timer parameter on the
network side unit.
User FS Polling Counter (N391)—The time interval (in seconds) at which
Status Enquiry occurs for full status (FS) polling: 1..255.
180
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
User Error Threshold (N392) / User ME Count (N393)—These parameters
are related. The User ME (Monitored Event) Count is the threshold period that
you set to determine a service-affecting condition. The unit monitors
events—receipt STATUS ENQUIRY messages or expiration of polling timers—for
the number of seconds (3..10) that you specify. Within this specified User ME
Count period, if an error occurs within the number of seconds that you specify
as the User Error Threshold (3..10), the system declares an error.
You must set the User Error Threshold to a lower value than that of the User ME
Count.
Configuring
QSIM/HSIM/FAM Cards
Configuring a QSIM/HSIM/FAM card involves the following tasks:
n
Configuring the card itself
n
Configuring input shapers
n
Configuring virtual interfaces
To configure the QSIM/HSIM/FAM card, follow these steps:
1 Configure the card itself.
a From the List Card menu, select the number corresponding to the slot in which
the QSIM, HSIM, or FAM is installed: [4], [5], or [6]. The QSIM Configuration
menu, shown earlier in Figure 138, appears.
b Select [5] Card Configuration ([9] Card Configuration on the FAM menu) to
display the QSIM, HSIM, or FAM Card Configuration menu. Figure 142 shows
the QSIM Card Configuration menu. The HSIM and FAM Card Configuration
menus are the same. The QSIM, HSIM, and FAM Card Configuration menus
display the current QSIM/HSIM/FAM card configuration and provide options
that allow you to change certain parameters.
Figure 142 QSIM Card Configuration Menu
Configuring Virtual Circuits
181
c If the Admin Status of the card is In Service, select [1] Set Admin. Status and
enter [1] to take the serial card out of service.
You must take the card out of service before you can change any configuration
settings.
d Set the following parameter as desired:
Max. Frame Size—The maximum frame size supported by the serial card: 2KB,
4KB, or 8KB. This value must match the maximum frame size for the device
interface to which the PathBuilder S700 is being connected. For example, if the
maximum frame size being transmitted to the PathBuilder S700 QSIM from a
Frame Relay Access Device (FRAD) is 4KB, then you must set the Maximum Frame
Size for the QSIM/HSIM card to 4KB.
If you change the Max. Frame Size setting, you will have to reset the card.
For information about QSIM, HSIM, and FAM performance at small frame sizes,
see “QSIM/HSIM/FAM Performance at Small Frame Sizes” earlier in this section.
e Return to the QSIM, HSIM, or FAM Configuration menu.
2 Configure input shapers for the QSIM/HSIM/FAM card.
a Select [6] Shaper Configuration ([10] Shaper Configuration on the FAM menu)
to open the QSIM, HSIM, or FAM Shapers screen. This screen is the same as the
MCPU Shapers screen, shown earlier in this chapter in Figure 88.
b Set the following input shaper parameters for the QSIM, HSIM, or FAM card:
n
Peak Cell Rate (PCR)
n
Sustained Cell Rate (SCR)
n
Maximum Burst Size (MBS)
For detailed instructions about configuring input shapers, see “Configuring
Input Shapers” earlier in this chapter.
c Return to the QSIM, HSIM, or FAM Configuration menu.
3 Configure virtual interfaces for the QSIM, HSIM, or FAM card.
a Select [7] Virtual Interfaces ([11] Virtual Interfaces on the FAM menu) to open
the QSIM, HSIM, or FAM Virtual Interfaces Configuration menu. This menu is
the same as the MCPU Virtual Interfaces menu, shown earlier in Figure 84.
b Configure virtual interfaces as described under “Configuring Virtual Interfaces”
earlier in this chapter. You configure virtual interfaces for the QSIM, HSIM, or
FAM card in the same way that you configure virtual interfaces for the MCPU
card.
Configuring Virtual
Circuits
Once you have configured the PathBuilder S700’s modules and ports, you can start
setting up virtual circuits. A virtual circuit is a bidirectional path between data ports
of connecting ATM units. You should have a circuit plan developed in advance.
The PathBuilder S700 supports both VPCs (virtual path connections) and VCCs
(virtual channel connections). A virtual path is an aggregate collection of virtual
channels for the purpose of assigning the channels to a single physical layer. A
virtual channel is a connection between data ports.
182
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
n
You define a VPC at the connecting units by assigning it a Virtual Path Identifier
(VPI) for each direction of transmission.
n
You define a VCC at the connecting units by assigning it a Virtual Path
Identifier (VPI) and a Virtual Channel Identifier (VCI) for each direction of
transmission. You can connect one or more virtual circuits to a data port by
assigning each a different VPI and VCI. The VPI and VCI numbers are normally
assigned as a pair: VPI/VCI.
You configure a virtual circuit between virtual interfaces from side A to side B, with
all traffic passing through an STX, as shown in Figure 143.
Figure 143 Two Sides of a VC Configuration
Side A
VI 1
STX
Rx
Side B
Rx
Tx
Tx
VI 2
Note that Receive (Rx) and Transmit (Tx) directions are from the perspective of the
STX module. Assign the Rx and Tx VPI/VCI for Side A and Side B based on the
diagram shown in Figure 143.
When you add a virtual circuit, you make a connection from the selected port to
for traffic to flow through the PathBuilder S700 and across the ATM WAN service.
Typically, the VPI and VCI numbers for one side of the circuit are assigned by the
network service provider or local IS administrator—depending on whether your
network is a public or private ATM network.
The port VPI/VCI ATM circuit designators must match the application being
supported. For example, if an OC3/STM-1 multi-mode fiber module is installed in
the Side B slot of the PathBuilder WAN Access Switch and is connected to a LAN
ATM switch device, then the Rx VPI/VCI for the ATM LAN interface must match the
Tx VPI/VCI for the OC3/STM-1 UNI module and vice versa. This ensures the first
step in making the connection into the PathBuilder S700.
Summary of Supported
VPI/VCI Ranges and
Number of Connections
Table 40 lists the VPI and VCI ranges and number of connections for all supported
card types.
The VPI/VCI ranges for the QSIM, HSIM, and FAM depend on the link type you
have chosen (DXI, HDLC/SDLC, or Frame Relay).
Configuring Virtual Circuits
183
N
Table 40 Summary of VPI/VCI Ranges and Supported Number of Connections
Card Type
Supported
VPI/VCI Range for VPI/VCI Range for Number of
Connections
VPC only
VCC
per Module
(Rx = Tx)
(Rx = Tx)
DS3/E3/OC3/STM-1UNI
VPI = 0... 255
VPI = 0... 255
VCI = 1... N*
2048
DS1/E1 IMA UNI
VPI = 0... 31
VPI = 0...31
VCI = 1... K**
256 per IMA
group
Ethernet/QSIM/HSIM/FAM
VPI = 0...255
VCI = 1... N
256
DSX-1 CBR
VPI = 0...255
VCI = 1... N
24 VCs per port
(24 timeslots)
E1 CBR
VPI = 0...255
VCI = 1... N
32 VCs per port
(32 timeslots)
*
N = (2048 - #VPIs-for-VCC) / #VPIs-for-VCC = 2047 for the default 1 VPI-for-VCC
= (32 - #VPIs-for-VCC) / #VPIs-for-VCC = 31 for the default 1 VPI-for-VCC
**K
For specific information about the number of connections supported for each
card, please see the PathBuilder S700 ATM WAN Access Switch Release Notes.
Adding Virtual Circuits
To define a new virtual circuit, follow these steps:
1 From the Configuration Management menu, select [2] Manage Circuit to display
the Virtual Circuit Menu, shown in Figure 144.
Figure 144 Virtual Circuit Menu
2 Select [2] Add Virtual Circuit to open the Add Virtual Circuit screen. As shown in
Figure 145, this screen prompts you to enter a description for the circuit.
184
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Figure 145 Initial Add Virtual Circuit Screen
3 Enter a description for the virtual circuit you are defining. After you enter a
description, you are prompted to specify the circuit type, as shown in Figure 146.
Figure 146 Add Virtual Circuit Screen—Selecting the Circuit Type
4 Configure a Unicast, MC Source, or MC Leaf circuit, as described in the following
subsections.
n
A Unicast circuit is a bidirectional circuit.
n
MC Source and MC Leaf circuits are both multicast circuits—circuits which are
to be multicast over other virtual circuits.
n
n
A MC Source (multicast source) circuit indicates the source of the multicast.
A MC Leaf (multicast leaf) circuit indicates the replication destination. It is
associated with a MC Source circuit.
Before you can configure a MC Leaf circuit, you must configure at least one MC
Source circuit.
Configuring Virtual Circuits
185
Configuring Unicast Virtual Circuits
To configure a unicast circuit, enter a circuit description, as described under
“Adding Virtual Circuits” earlier in this section, then follow these steps from the
Add Virtual Circuit screen shown in Figure 146:
1 Enter 1 to specify the circuit type as Unicast.
You are prompted to specify the VC connection type of the circuit you are
configuring, as shown in Figure 147.
Figure 147 Add Virtual Circuit Screen—Selecting the VC Connection Type
2 Enter the number corresponding to the type of virtual circuit connection you want
to configure: VCC or VPC. The connection type determines how the VPI and VCI
are translated.
VCC (virtual channel connection)—You can use this connection type for circuit
between non-UNI and UNI cards and between UNI and UNI cards; both the VPIs
and the VCIs will be translated.
VPC (virtual path connection)—You can use this connection type only for circuits
between UNI and UNI cards; only the VPIs will be translated.
To operate a circuit as a VP, set the connection type to VPC.
The Add Virtual Circuit Screen lists the cards available for side A of the circuit, by
slot number, and prompts you to select a slot number, as shown in Figure 148.
186
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Figure 148 Add Virtual Circuit Screen—Specifying the Slot # for Side A
3 Enter the slot number for the card that you want to define as side A of the virtual
circuit. For example, from the Add Virtual Circuit screen show in Figure 148, if you
wanted to select the E3 UNI card as side A, you would enter 7.
The default slot number is indicated by an asterisk. To select the default slot
number, simply press [Enter].
You can also create an in-band circuit between two nodes by defining the
PathBuilder S700 MCPU slot—with its own IP address—as one side of the virtual
circuit. This enables you to manage a remote hub from a local network
management station. See “Configuring In-band Management” in Chapter 3 for
details.
After you enter the slot number, the Add Virtual Circuit screen displays the
selected slot number and card type, lists the parameters you will enter for side A of
the circuit, and prompts you to set the first parameter, as shown in Figure 149. For
parameter descriptions, by card, see “Virtual Circuit Parameters” later in this
chapter.
If the card you select has multiple ports, you are prompted to specify the port
number as the first parameter for side A of the circuit.
Configuring Virtual Circuits
187
Figure 149 Add Virtual Circuit Screen—Entering the First VC Parameter for Side A
4 Follow the prompts that appear at the bottom of the screen, pressing [Enter] after
each entry. Default values are listed in square brackets ([ ]) at the end of each
prompt.
Your settings are added to the list of parameters at the top of the screen as you
enter them. You must enter a setting for all the parameters for which you are
prompted in order to add a circuit. Press [Delete] to back up to a previous
selection.
Some parameters that appear on the Add Virtual Circuit screen may not apply to
the particular circuit you are configuring. The system skips any non-applicable
parameters and does not allow you to set them. In addition, certain parameters
may be displayed for information only; you cannot change these read-only values.
When you have entered a setting for each parameter on side A of the circuit, the
Add Virtual Circuit again displays the list of available PathBuilder S700 cards, by
slot number, and prompts you to enter a slot number for side B of the circuit, as
shown in Figure 150.
188
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Figure 150 Add Virtual Circuit Screen—Selecting the Card for Side B of the Circuit
5 For side B of the circuit, select the slot number corresponding to the module
through which you are connected to the network.
After you enter the last parameter for side B, the following prompt appears at the
bottom of the screen:
Enter Admin Status (1 = Out of Service, 2 = In Service)
6 Set the administrative status of the circuit as desired.
The following prompt appears at the bottom of the screen, as shown in
Figure 151:
Is above information correct? (y/n, [y]):
Figure 151 Completed Unicast Virtual Circuit
7 Enter y to confirm your configuration. A message similar to the following
appears at the bottom of the screen:
VC has been added
Press any key to continue
Configuring Virtual Circuits
189
Configuring Multicast Source Virtual Circuits
To configure a multicast source circuit, enter a circuit description, as described
under “Adding Virtual Circuits” earlier in this section, then follow these steps from
the Add Virtual Circuit screen shown in Figure 146:
1 Enter 2 to specify the circuit type as MC Source.
The Add Virtual Circuit Screen lists the cards available for side A of the circuit, by
slot number, and prompts you to select a slot number, as shown earlier in
Figure 148.
2 Enter the slot number for the card that you want to define as side A of the virtual
circuit.
The default slot number is indicated by an asterisk. To select the default slot
number, simply press [Enter].
After you enter the slot number, the Add Virtual Circuit screen displays the
selected slot number and card type, lists the parameters you will enter for side A of
the circuit, and prompts you to set the first parameter, as shown earlier in
Figure 149. For parameter descriptions, by card, see “Virtual Circuit Parameters”
later in this chapter.
If the card you select has multiple ports, you are prompted to specify the port
number as the first parameter for side A of the circuit.
3 Follow the prompts that appear at the bottom of the screen, pressing [Enter] after
each entry. Default values are listed in square brackets ([ ]) at the end of each
prompt.
Your settings are added to the list of parameters at the top of the screen as you
enter them. You must enter a setting for all the parameters for which you are
prompted in order to add a circuit. Press [Delete] to back up to a previous
selection.
Some parameters that appear on the Add Virtual Circuit screen may not apply to
the particular circuit you are configuring. The system skips any non-applicable
parameters and does not allow you to set them. In addition, certain parameters
may be displayed for information only; you cannot change these read-only values.
After you enter the last parameter for side A, the following prompt appears at the
bottom of the screen:
Enter Admin Status (1 = Out of Service, 2 = In Service)
A multicast source virtual circuit has no side B.
4 Set the administrative status of the circuit as desired.
The following prompt appears at the bottom of the screen:
Is above information correct? (y/n, [y]):
5 Enter y to confirm your configuration.
A message confirming that the circuit has been added appears at the bottom of
the screen, as shown in Figure 152.
190
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Figure 152 Completed Multicast Source Virtual Circuit
Configuring Multicast Leaf Virtual Circuits
To configure a multicast source circuit, enter a circuit description, as described
under “Adding Virtual Circuits” earlier in this section, then follow these steps from
the Add Virtual Circuit screen shown in Figure 146:
1 Enter 3 to specify the circuit type as MC Leaf.
Because each multicast leaf circuit is associated with a specific multicast source
circuit, you must configure at least one multicast source circuit before you can
configure a multicast leaf circuit.
You are prompted to enter the multicast ID of the multicast source circuit with
which you want to associate the multicast leaf circuit.
If necessary, use the List Virtual Circuit screen—described under “Viewing Existing
Virtual Circuits” later in this chapter—to determine the multicast ID of the desired
multicast source circuit.
2 Enter the appropriate multicast ID.
The configuration parameters for the multicast source circuit you specified appear
in the side A section of the Add Virtual Circuit screen, and you are prompted to
enter a slot number for side B of the circuit.
3 Enter the slot number for the card that you want to define as side B of the virtual
circuit.
The default slot number is indicated by an asterisk. To select the default slot
number, simply press [Enter].
After you enter the slot number, the Add Virtual Circuit screen displays the
selected slot number and card type, lists the parameters you will enter for side B of
the circuit, and prompts you to set the first parameter. For parameter descriptions,
by card, see “Virtual Circuit Parameters” later in this chapter.
If the card you select has multiple ports, you are prompted to specify the port
number as the first parameter for side B of the circuit.
Configuring Virtual Circuits
191
4 Follow the prompts that appear at the bottom of the screen, pressing [Enter] after
each entry. Default values are listed in square brackets ([ ]) at the end of each
prompt.
Your settings are added to the list of parameters at the top of the screen as you
enter them. You must enter a setting for all the parameters for which you are
prompted in order to add a circuit. Press [Delete] to back up to a previous
selection.
Some parameters that appear on the Add Virtual Circuit screen may not apply to
the particular circuit you are configuring. The system skips any non-applicable
parameters and does not allow you to set them. In addition, certain parameters
may be displayed for information only; you cannot change these read-only values.
After you enter the last parameter for side B, the following prompt appears at the
bottom of the screen:
Enter Admin Status (1 = Out of Service, 2 = In Service)
5 Set the administrative status of the circuit as desired.
The following prompt appears at the bottom of the screen.
Is above information correct? (y/n, [y]):
6 Enter y to confirm your configuration. A message confirming that the circuit has
been added appears at the bottom of the screen, as shown in Figure 153.
Figure 153 Completed Multicast Leaf Virtual Circuit
Virtual Circuit
Parameters
The following subsections describe the parameters you must enter when you
configure virtual circuits for different card types.
The parameters that you will actually see during configuration will depend on the
circuit type and the card type of your configuration. Also, some of the parameters
will appear on either side A or side B.
192
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Common Virtual Circuit Parameters
The following virtual circuit parameters are available for most PathBuilder S700
cards:
For descriptions of the virtual circuit parameters for the MCPU card, see
“Configuring In-band Management” in Chapter 3.
Virtual Interface—Side A (or B) Virtual Interface number.
Priority—The priority for this circuit: 0, 1, 2, or 3. The STX supports four priority
queues per virtual interface, and each virtual circuit can be mapped to a priority
queue. Priority 0 is the highest.
Early Packet Discard—Enable or disable early packet discard (EPD) for use with
the Congestion On/Off setting. See “Configuring the STX Module” for details. For
every connection where early packet discard is enabled, a status is kept when
there is a partial packet for that connection in the queue. Once the queue cell level
exceeds the congestion ON thresholds, only connections with partial packets
already existing in the queue are allowed in. Cells from other connections are
dropped.Once the congestion has subsided to the congestion OFF level, then all
remaining connections are allowed.
Policing—Select [0] to disable, [1] to choose Config. 1, or [2] to choose Config. 2.
If you select Config. 1, the following occurs:
n
For priority = 0 VCs, CLP=0 cells are policed and non-conforming CLP=0 cells
are tagged. CLP=1 cells are not policed. The policing for CBR traffic is based on
PCR and CDVT.
n
For priority = 1-3 VCs, CLP=0 cells are policed, SCR is enforced, and
non-conforming CLP=0 cells are tagged. Additionally, CLP=0+1 (all cells) are
policed, and PCR is enforced such that any cells exceeding PCR are discarded.
The policing for non-CBR traffic is based on PCR, SCR, and MBS.
If you select Config. 2, the following occurs:
n
For priority = 0 VCs, CLP=0+1 cells are policed and non-conforming cells are
dropped. The policing for CBR traffic is based on PCR and CDVT.
n
For priority = 1-3 VCs, CLP=0 cells are policed and SCR is enforced such that
non-conforming CLP=0 cells are tagged. Additionally, CLP=1 cells are policed
and PCR is enforced such that non-conforming CLP=1 cells are discarded. The
policing for non-CBR traffic is based on PCR, SCR, and MBS.
PCR/CDVT/SCR/MBS—Set the policing parameters.
PCR—Peak Cell Rate; the maximum cell rate which the source may never
exceed. This is the interval from the first bit of one cell to the first bit of the
next cell.
CDVT—Cell Delay Variation Tolerance; the acceptable tolerance of CDV. CDV is
a Quality of Service parameter that measures the peak-to-peak cell delay
through the network. It represents the difference between the worst case delay
and the best case delay achievable on the VC.
SCR—Sustainable Cell Rate—the maximum average rate (in cells/sec) that a
bursty on-off traffic source that can be sent at the peak rate.
MBS—Maximum Burst Size; the maximum number of cells that can be sent at
the peak rate.
Configuring Virtual Circuits
193
ATM Module Virtual Circuit Parameters
The following virtual circuit parameters are specific to E3 UNI, DS3 UNI,
OC3/STM-1 UNI, DS1 UNI with IMA, and E1 UNI with IMA cards.
Group—The IMA group number (if applicable).
Receive VPI—The VPI of cells received.
Receive VCI—The VCI of cells received.
Transmit VPI—The transmit VPI of cells transmitted.
Transmit VCI—The transmit VCI of cells transmitted.
The receive VPI/VCI and transmit VP/VCI numbers must be unique within their own
card.
Ethernet Module Virtual Circuit Parameters
You build connections from the local Ethernet port to a remote Ethernet port by
adding Permanent Virtual Circuits (PVCs). These connections allow the packets to
be transmitted through the ATM network to the destination port.
The following virtual circuit parameters are specific to Ethernet cards:
Shaper—Select one of the 15 Shaper values that you configured under Manage
Card. You assign the Shaper value to ensure adequate traffic flow to and through
the ATM WAN. The Shaper parameter is key in ensuring that your traffic does not
exceed the negotiated traffic contract as administered by the service department
or IS department.
CBR Module Virtual Circuit Parameters
You set up an emulated circuit connection from the DSX-1 CBR or E1 CBR port to
a remote DSX-1 CBR or E1 CBR port by mapping DS1 circuits to permanent virtual
circuits (PVCs). These circuits are then transmitted through the ATM network to
the destination port.
The following virtual circuit parameters are specific to CBR cards:
Mode (structured data ports only)—Virtual circuit mode: Normal (normal PVC
mode), RS366, or DBA.
Normal—The circuit is configured as a standard PVC circuit and does not listen
to video signals.
RS366—The circuit is put into an active listener mode; it listens for video
signals from premises devices. This mode is typically used in RS-366 video
session.s
DBA—The circuit is configured to dynamically reassign the timeslot. This mode
supports dynamic bandwidth allocation.
CDV Buffer size—The Cell Delay Variation for the provisioned CBR circuit as
indicated by the network (carrier) or external test measurement: 1-24 ms.
Cell Loss Integration Period—The amount of time the system will wait before
declaring cell loss state: 2000-65535 ms.
Payload Size/Type (structured voice DSX-1 ports only)—Select data or voice.
Select voice to configure a structured voice port for dynamic bandwidth allocation
(DBA).
194
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Onhook Detection—Enables or disables on-hook detection. When you enable
on-hook detection, bandwidth is automatically reallocated based on detection of
an on-hook condition, as specified by the signaling type.
Signaling Type—The signaling application type: No Signaling, E&M/PLAR,
FXO-LoopStart, FXS-LoopStart, or FXO-GroundStart for DSX-1 CBR; R2 for E1 CBR.
You can only modify this field in structured voice mode. In this mode, you can
select any signaling application type except No Signaling. If you try to set the
Signaling Type to No Signaling in structured voice mode, you will get an error. In
structured/unstructured data modes, the Signaling Type defaults to No Signaling
and cannot be modified. Configured under Manage Card. Select E&M/PLAR to
configure for dynamic bandwidth allocation (DBA) over ISDN PRI.
DS0 Channels—The associated DSOs which have been assigned to the specified
ATM VC connection. All available DSO channels are automatically allocated in
unstructured mode. In structured mode, the DSO channels are bit-coded, with
each bit representing one DSO channel. You can assign DSO channels in
structured mode only. Channel conflicts within a T1/E1 port interface will result in
an error.
Configuring CBR Virtual Circuits for DBA The PathBuilder S700 supports two
types of dynamic bandwidth allocation (DBA): structured voice DBA and structured
data DBA. For details about how DBA works, see “DS0 Signaling and Dynamic
Bandwidth Allocation” in Chapter 4.
In structured voice DBA, the CBR software reads the stored signaling bits and
releases bandwidth when it detects an on-hook (idle) condition. To configure a
CBR virtual circuit for structured voice DBA, follow these basic steps:
1 Configure the CBR Port as follows:
n
Set the CBR Port Mode to Structured Voice. See “Configuring DSX-1 CBR or E1
CBR Modules” earlier in this chapter for details about setting CBR port
parameters.
2 Configure the virtual circuit as follows:
n
Set the Mode to DBA.
n
Set the Payload Size/Type to Voice.
n
Set Onhook Detection to Enabled.
n
Set the Signaling Type to E&M/PLAR,
In structured data DBA, the CBR software reads the DSO payload bytes and
releases bandwidth when it detects an on-hook (idle) condition. To configure a
CBR virtual circuit for structured data DBA, follow these basic steps:
1 Configure the CBR port as follows:
n
Set the Port Mode to Structured Data. See “Configuring DSX-1 CBR or E1 CBR
Modules” earlier in this chapter for details about setting CBR port parameters.
n
Set the DBA Bits Mask to mask off bits that you do not want to include in the
idle code.
2 Configure the virtual circuit as follows:
n
Set the Mode to DBA.
n
Set the Payload Size/Type to Voice.
n
Set Onhook Detection to Enabled.
Configuring Virtual Circuits
195
Setting up a PRI PBX Tie Line PRI signaling is a type of CCS (common channel
signaling) in which one channel (24) is used to signal for the other channels (1-23).
This is in contrast to CAS (channel associated signaling) in which signaling is done
on all channels.
You can set up a PRI PBX tie line that allows structured data to be passed across a
structured data port. To do this, follow these basic steps:
1 Set the CBR Port Mode to Structured Voice. See “Configuring DSX-1 CBR or E1
CBR Modules” earlier in this chapter for details about setting CBR port
parameters.
2 For channel 24, build a structured data virtual circuit with on-hook detection
disabled.
3 For channels 1-23, build individual structured data virtual circuits for each DS0 you
will actually use, with on-hook detection enabled.
QSIM/HSIM/FAM Virtual Circuit Parameters
The parameters that appear on the QSIM, HSIM, or FAM Add Virtual Circuit screen
vary, depending on the configuration of the serial port that is being connected:
Frame Relay, DXI, or HDLC/SDLC.
The following virtual circuit parameters are specific to QSIM/HSIM/FAM cards:
The configuration of the card you select on the List Card menu sets the attribute
selection for the virtual circuit configuration parameters. If you configure a virtual
circuit and then change serial port attributes—from DXI to Frame Relay or vice
versa—the circuit will be deleted.
Frame Relay Virtual Circuit Parameters If the serial port is configured as a
Frame Relay port, you must set the following virtual circuit parameters:
Interworking Mode—The Frame Relay/ATM interworking mode: Network or
Service.
Start Frame Relay DLCI—The starting Frame Relay data link connection
identifier: 16...991. DLCI is used to identify a Frame Relay local connection. In
Network interworking mode, contiguous values of DLCIs can be mapped to a VCI.
Many DLCI to One VCI mapping is supported as well as One DLCI to One VCI
mapping.
End Frame Relay DLCI—The ending Frame Relay data link connection identifier:
16...991. DLCI is used to identify a Frame Relay local connection. In Network
interworking mode, contiguous values of DLCIs can be mapped to a VCI.
Encapsulation Mode—The encapsulation data goes around the data packet and
is used to identify the packet; select 1 (Transparent) or 2 (Translation). This feature
is offered only for Service interworking mode.
Transparent—Used for point-to-point frame relay interconnection. See
Figure 154. Frame Relay Forum 8 (FRF.8) Service Interworking for this is being
implemented. There are two modes at which FRF.8 specifies a mode which is
transparent and is in fact 1490 over ATM.
196
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Figure 154 FRF.8 Transparent Encapsulation Mode
DLCI
VCC
FRR
DLCI
ATM
PathBuilder
FRR
PathBuilder
S700
S700
RFC 1490 Encapsulated
Translation—Used in cases when you have ATM devices that do not support
1490 as a protocol across their ATM trunks; for example, when you have an
PathBuilder S700 terminating the ATM network at one end and an ATM-ready
device, such as a router with an OC-3 UNI, at the other end. Typically these
ATM-ready devices do not support 1490 as a protocol across their ATM trunks, so
you have to do LLC_SNAP (1483) per FRF.8. Mode 1F does 1490 to 1483
translation. See Figure 155.
Figure 155 Translation Encapsulation Mode
DLCI
VCC
ATM Router with FRR IWF
FRR
ATM
PathBuilder
PathBuilder
S700
S700
Translation
RFC 1490
RFC 1483
DE to CLP Mapping—Frame Relay Discard Eligibility field to Cell Loss Priority field
mapping. This parameter defines the value to which CLP will be set in outgoing
ATM cells. The available settings depend on what interworking mode you have
selected: Network or Service.
The following settings are available for Network interworking mode:
Direct—Mode 1 mapping; matches DE value to CLP value. When the serial
port is in this mode, it does not translate Frame Relay (NLPID) encapsulation,
rather it sends it straight through the ATM network, possibly to a Frame Relay
network or device.
None—No DE to CLP Mapping
Configuring Virtual Circuits
197
The following settings are available for Service interworking mode:
Direct—Mode 1 mapping; matches DE value to CLP value. When the serial
port is in this mode, it does not translate Frame Relay (NLPID) encapsulation,
rather it sends it straight through the ATM network, possibly to a Frame Relay
network or device.
Always-0—Mode 2 mapping, with the CLP field mapped to a constant value
of 0. Mode 2 is an operational method for indicating data congestion to either
the ATM or Frame Relay network. Mode 2 allows for translation between
NLPID and LLC-SNAP encapsulation. It is used when connecting a Frame Relay
device or network to a non-Frame Relay device or network. For example, if the
PathBuilder S700 is connecting a router/FRAD over an ATM network (public or
private) and at the other site a router with an ATM OC3 UNI is connected to
the WAN network, typically the router OC3 UNI does not support NLPID and
requires mode 2 mapping so that the packet can be encapsulated to LLC-SNAP.
Always-1—Mode 2 mapping, with the CLP field mapped to a constant value
of 1. Mode 2 is an operational method for indicating data congestion to either
the ATM or Frame Relay network. Mode 2 allows for translation between
NLPID and LLC-SNAP encapsulation. It is used when connecting a Frame Relay
device or network to a non-Frame Relay device or network. For example, if the
PathBuilder S700 is connecting a router/FRAD over an ATM network (public or
private) and at the other site a router with an ATM OC3 UNI is connected to
the WAN network, typically the router OC3 UNI does not support NLPID and
requires mode 2 mapping so that the packet can be encapsulated to LLC-SNAP.
CLP to DE Mapping—Cell Loss Priority field to Frame Relay Discard Eligibility field
mapping. This parameter defines the value to which DE will be set from incoming
ATM cells in outgoing Frame Relay frames. The available settings depend on what
interworking mode you have selected: Network or Service.
n
The following settings are available for Network interworking mode:
Direct—Mode 1 mapping; matches CLP value to DE value. When the serial
port is in this mode, it does not translate Frame Relay (NLPID) encapsulation,
rather it sends it straight through the ATM network, possibly to a Frame Relay
network or device.
None—No CLP to DE mapping.
n
The following settings are available for Service interworking mode:
Direct—Mode 1 mapping; matches CLP value to DE value. When the serial
port is in this mode, it does not translate Frame Relay (NLPID) encapsulation,
rather it sends it straight through the ATM network, possibly to a Frame Relay
network or device.
Always-0—Mode 2 mapping, with the DE field mapped to a constant value of
0. Mode 2 is an operational method for indicating data congestion to either
the ATM or Frame Relay network. Mode 2 allows for translation between
NLPID and LLC-SNAP encapsulation. It is used when connecting a Frame Relay
device or network to a non-Frame Relay device or network. For example, if the
PathBuilder S700 is connecting a router/FRAD over an ATM network (public or
private) and at the other site a router with an ATM OC3 UNI is connected to
the WAN network, typically the router OC3 UNI does not support NLPID and
requires mode 2 mapping so that the packet can be encapsulated to LLC-SNAP.
198
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Always-1—Mode 2 mapping, with the DE field mapped to a constant value of
1. Mode 2 is an operational method for indicating data congestion to either
the ATM or Frame Relay network. Mode 2 allows for translation between
NLPID and LLC-SNAP encapsulation. It is used when connecting a Frame Relay
device or network to a non-Frame Relay device or network. For example, if the
PathBuilder S700 is connecting a router/FRAD over an ATM network (public or
private) and at the other site a router with an ATM OC3 UNI is connected to
the WAN network, typically the router OC3 UNI does not support NLPID and
requires mode 2 mapping so that the packet can be encapsulated to LLC-SNAP.
Start FR-SSCS DLCI—The starting Frame Relay data link connection identifier of
the remote ATM Frame Relay host: 16...991. This parameter applies only to
Network interworking model. In Network interworking mode, contiguous values
of SSCS can be mapped to a VCI.
End FR-SSCS DLCI—The ending Frame Relay data link connection identifier of the
remote ATM Frame Relay host: 16...991. This parameter applies only to Network
interworking model. In Network interworking mode, contiguous values of SSCS
can be mapped to a VCI.
FECN to EFCI Mapping—Forward Explicit Congestion Notification to Explicit
Forward Congestion Indication mapping. This parameter defines the mapping of
FECN incoming on Frame Relay to the outgoing ATM cell PTI congestion indicator.
It applies only to Service interworking mode.
Direct—Mode 1 mapping; matches FECN to the PTI CN bit. When the serial port is
in this mode, it does not translate Frame Relay (NLPID) encapsulation, rather it
sends it straight through the ATM network, possibly to a Frame Relay network or
device.
Always-0—Mode 2 mapping. This option sets the EFCI field to ‘congestion
not experienced.’ Mode 2 is an operational method for indicating data
congestion to either the ATM or Frame Relay network. Mode 2 allows for
translation between NLPID and LLC-SNAP encapsulation. It is used when
connecting a Frame Relay device or network to a non-Frame Relay device or
network. For example, if the PathBuilder S700 is connecting a router/FRAD over
an ATM network (public or private) and at the other site a router with an ATM
OC3 UNI is connected to the WAN network, typically the router OC3 UNI does
not support NLPID and requires mode 2 mapping so that the packet can be
encapsulated to LLC-SNAP.
Shaper Number—Select one of the 15 Shaper values that you configured under
Manage Card. You assign the Shaper value to ensure adequate traffic flow to and
through the ATM WAN. The Shaper parameter is key in ensuring that your traffic
does not exceed the negotiated traffic contract as administered by the service
department or IS department.
DXI Virtual Circuit Parameters If the serial port is configured as a DXI port,
you must set the following virtual circuit parameters:
(DFA) VPI—The virtual path indicator (VPI) number corresponding to the DFA
field: 0...15. This parameter defines the selected VPI for Mapping to/from the Port
card (Router) to the trunk.
Configuring Virtual Circuits
199
(DFA) VCI—The virtual channel indicator (VCI) number corresponding to the DFA
field: 0...63. This parameter defines the selected VPI for Mapping to/from the Port
card (Router) to the trunk.
(DFA) VCI Range—The DXI virtual channel indicator range: 1...64. If you set this
parameter to a value other than 1, the system adds the specified number of VCs
and increments the DFA VCI and the other side’s DFA or ATM VCIs in parallel.
Shaper Number—Select one of the 15 Shaper values that you configured under
Manage Card. You assign the Shaper value to ensure adequate traffic flow to and
through the ATM WAN. The Shaper parameter is key in ensuring that your traffic
does not exceed the negotiated traffic contract as administered by the service
department or IS department.
Early Packet Discard—Enables or disables early packet discard. For every
connection where early packet discard is enabled, a status is kept when there is a
partial packet for that connection in the queue. Once the queue cell level exceeds
the congestion ON thresholds, only connections with partial packets already
existing in the queue are allowed in. Cells from other connections are dropped.
HDLC/SDLC Virtual Circuit Parameters If the serial port is configured as a
HDLC/SDLC port, you must set the following virtual circuit parameter:
Shaper Number—Select one of the 15 Shaper values that you configured under
Manage Card. You assign the Shaper value to ensure adequate traffic flow to and
through the ATM WAN. The Shaper parameter is key in ensuring that your traffic
does not exceed the negotiated traffic contract as administered by the service
department or IS department.
Viewing Existing Virtual
Circuits
You can view summaries of existing virtual circuits for the entire chassis or by port
or group.
Viewing Virtual Circuits for the Entire Chassis
To view a summary of existing virtual circuits for the entire chassis, follow these
steps:
1 From the Configuration Management menu, select [2] Manage Circuit to open the
Virtual Circuit menu, shown earlier in Figure 144
2 From the Virtual Circuit menu, select [1] List Virtual Circuits to open the List Virtual
Circuit Summary screen, shown in Figure 156.
200
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Figure 156 List Virtual Circuit Summary Screen
The List Virtual Circuit Summary Screen shows a summary of all virtual circuits,
with a virtual circuit number (VC#) assigned to each. It displays the following
information:
card—Card type. For multicast source circuits, this column lists the notation MC
<ID> Source, where <ID> is the multicast ID number.
s/p:vi—Slot, port, and virtual interface numbers (for side A and side B of the
circuit)
Rx/Tx—Virtual circuit information specific to the card type. For example, for UNI
cards, these columns list the receive/transmit VPI/VCI (for side A and side B of the
circuit), while for CBR cards these columns list the DS0 channels.
Description—The description entered when the circuit was configured.
3 To view more detailed information about a specific virtual circuit enter the VC# of
the circuit you want to view from the List Virtual Circuit Summary screen to open
the List Virtual Circuit Detail screen. This screen displays the complete list of
parameters for both sides of the selected circuit.
Figure 157 shows a representative List Virtual Circuit detail screen for an E1 UNI
card. Figure 158 shows a representative List Virtual Circuit Detail Screen for a CBR
card.
Configuring Virtual Circuits
201
Figure 157 List Virtual Circuit Detail Screen - E1 UNI
Figure 158 List Virtual Circuit Detail Screen - CBR
Viewing Virtual Circuits by Port or Group
To view a summary of existing virtual circuits for a selected port or group, follow
these steps:
1 From the Configuration Management menu, select [2] Manage Circuit to open the
Virtual Circuit menu, shown earlier in Figure 144
2 From the Virtual Circuit menu, select [6] Access Virtual Circuits by Port/Group to
open the Access VCs by Port/Group Selection menu, shown in Figure 159. This
menu lists the ports and groups on the chassis for which virtual circuits have been
defined and the number of VC sides associated with each port/group.
202
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Figure 159 Access VCs by Port/Group Selection Menu
3 Enter the number corresponding to the port or group for which you want to view
virtual circuits to open the Access Virtual Circuits by Port/Group screen, shown in
Figure 160.
Figure 160 Access Virtual Circuits by Port/Group Screen
The Access Virtual Circuits by Port/Group screen provides the same information as
the List Virtual Circuit screen. See “Viewing Virtual Circuits for the Entire Chassis”
earlier in this section for details.
Configuring Virtual Circuits
Modifying Virtual
Circuits
203
To modify an existing virtual circuit, follow these steps:
1 From the Virtual Circuit menu, select [3] Modify Virtual Circuit to open the Modify
Virtual Circuit menu, shown in Figure 161. This menu displays a list of existing
virtual circuits.
Figure 161 Modify Virtual Circuit Configuration Screen
2 Enter the VC# of the circuit you want to modify to open the Modify Virtual Circuit
Configuration menu for that circuit. Figure 162 shows a representative Modify
Virtual Circuit Configuration menu.
Figure 162 Modify Virtual Circuit Configuration Menu
3 Modify the virtual circuit by setting parameters in the same way that you did when
you configured the circuit, See “Adding Virtual Circuits” earlier in this chapter, for
details.
204
CHAPTER 5: CONFIGURING PATHBUILDER S700 MODULES, PORTS, AND APPLICATIONS
Deleting Virtual Circuits
To delete an existing virtual circuit, follow these steps:
1 From the Virtual Circuit menu, select [4] Delete Virtual Circuit. The Delete Virtual
Circuit screen appears. This screen displays a list of existing virtual circuits.
2 Enter the VC# of the circuit you want to delete.
3 Enter y in response to the confirmation prompt to delete the circuit.
Viewing Virtual Circuit
Statistics
You can view the following types of virtual circuit statistics—either by circuit or by
port/group:
n
A summary of statistics for all virtual circuits
n
A detailed list of statistics for a specific circuit
To view virtual circuit statistics, follow these steps:
From the Virtual Circuit menu, select either [5] Show Virtual Circuit Statistics or
[6] View Virtual Circuit Statistics by Port/group.
For details about the statistics listed on the virtual circuit statistics screens, see
“Viewing Virtual Circuit Statistics” in Chapter 6.
6
PATHBUILDER S700 DIAGNOSTICS
AND PERFORMANCE MONITORING
This chapter tells you how to access and manage the alarms supported by the
PathBuilder S700 WAN access switch (PathBuilder S700), how to set loopbacks,
and how to view performance statistics. The chapter also lists the supported
alarms, loopbacks, and statistics that are available for specific modules. It contains
the following sections:
Managing System
Alarms
n
Managing System Alarms
n
Using Loopbacks
n
Viewing Statistics
The PathBuilder S700 detects certain events and reports corresponding alarms to
the NMS station(s). These events are categorized as major alarms, minor alarms,
and information. When an alarm occurs, an alarm indicator is displayed in the
upper right corner of the current menu or display, as described under “Alarm
Indicator” in Chapter 3.
The PathBuilder S700 also utilizes an alarm task to relay the alarm from other tasks
to the MCPU. This task is designed particularly for off-loading the data transport
task. When the data transport task detects an error which has to be reported, it
sends a message to the Alarm task. In this way, the data transport task can
continue the system-critical task of processing traffic.
Viewing and Clearing
Current Alarms
To view a list of current alarms, follow these steps:
1 From the Main menu, select [3] Fault Management to display the Fault
Management menu shown in Figure 163.
206
CHAPTER 6: PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING
Figure 163 Fault Management Menu
2 Select [1] Display Current Alarms to view the Display Current Alarm screen, shown
in Figure 164.
Figure 164 Display Current Alarm Screen
To clear the current alarms, follow these steps:
1 From the Display Current Alarm screen, press [Esc] to return to the Fault
Management menu.
2 Select [2] Clear Current Alarms. The following prompt appears:
Do you want to clear current alarms (Y/N) [N]?
3 Enter y to clear the current alarms.
Managing System Alarms
PathBuilder S700 Alarm
Messages
207
This section lists the alarm messages, meanings of the alarm messages, and
troubleshooting tips for the major errors reported from each of the PathBuilder
S700 interfaces. It contains the following subsections:
n
MCPU and STX Module (System) Alarms
n
Alarms Common to Several Modules
n
DS1/E1 UNI Module Alarms
n
DSX-1/E1 CBR Module Alarms
n
QSIM/FAM Alarms
MCPU and STX Module (System) Alarms
Table 41 describes the Critical and Major Alarms associated with the CPU Module.
Table 41 MCPU and STX Module (System) Alarms
Alarm
Meaning
A card is removed
from a card slot
A card has been removed from Install the card.
the shelf.
Troubleshooting Steps
Alarms Cleared
Current alarms have been
cleared by user.
ALM Dest Slot
Overrun
The destination slot has failed Find and replace the defective card.
and is not taking cells from the
STX card.
ALM Ext SRAM
Parity Er
STX hardware failure.
Replace the STX card.
ALM Ingress FIFO
Overflow
STX hardware failure.
Replace the STX card.
ALM Ingress Sync
Error
STX hardware failure.
Replace the STX card.
ALM Ingress VCI
Out of Range
The cells received by the STX
Verify the integrity of the incoming
have a VCI that is out of range. traffic, checking to see if the traffic
matches the assigned VPIs. Replace the
port card. Replace the STX card.
ALM Ingress VPI
Over 255
The cells received by the STX
have an improper VPI value.
Verify the integrity of the incoming
traffic, checking to see if the traffic
matches the assigned VPIs. Replace the
port card. Replace the STX card.
ALM Parity Error
Egress/QCX
STX hardware failure
Replace the STX card.
ALM Parity Error
Ingress/CB
STX hardware failure
Replace the STX card.
Information only.
BITS reference clock Enabled when the BITS clock is Check the BITs clock source for other
failure
selected as the timing source
alarms.
but has failed.
Bus A Parity Error
STX hardware failure.
Replace the STX card.
Bus B Parity Error
STX hardware failure.
Replace the STX card.
Bus C Parity Error
STX hardware failure.
Replace the STX card.
Bus D Parity Error
STX hardware failure.
Replace the STX card.
Bus E Parity Error
STX hardware failure.
Replace the STX card.
Bus F Parity Error
STX hardware failure.
Replace the STX card.
(continued)
208
CHAPTER 6: PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING
Table 41 MCPU and STX Module (System) Alarms (continued)
Alarm
Meaning
Troubleshooting Steps
Card Config Failed
Cannot upload configuration
data to a card.
Information only. Could indicate a
potential problem. You may need to
reset the card.
Card initialized.
Card initialized.
Information only.
Card not installed
The required card is physically
not present. (STX)
Install the card.
Card Reconfig
Failed
Reconfiguration of the card
failed
Information only. Could indicate a
potential problem. You may need to
reset the card.
Card Reconfigured
Card is reconfigured.
Information only. Could occur when
the card is plugged in or the system is
powered up.
Cardtype Invalid
An unknown card type is
detected in a card slot.
Information only.
Cardtype
mismatched
The card type of a card slot in Information only.
the database does not match
the card type of the same card
slot in the shelf.
Communication
Failed
Error during communication
between MCPU and a slot.
Reseat the non-CPU slot. Replace the
MCPU if no improvement.
DS3/E3/OC3/CBR/
IMA/FAM Ref Clk
Failed
Interface clock has been
designated as the system clock,
and the interface clock has
failed.
Check the physical connection. Check
for other alarms such as
LOS/LOF/LOCD. Check the physical
connection.
Fan #1 failed
Fan #1 failed
Replace the fan tray.
Fan #2 failed
Fan #2 failed
Replace the fan tray.
Fan #3 failed
Fan #3 failed
Replace the fan tray.
Firmware Versions
Mismatch
The firmware versions in the
Information only.
active and standby flash image
are not the same.
History Overflowed
Alarm history table has
overflowed. Alarms will
continue to be recorded but
will displace oldest alarms.
Id Prom Checksum
Error
The internal checksum on the Have the idprom replaced with the
idprom of the indicated card is correct version. The system takes no
incorrect.
action if it recognizes the proper card
ID.
Clear the history alarms table through
NMS or Telnet.
Invalid DB Cardtype An unknown card type is
found in the database
Information only.
Login Failure
Failed log -in. Someone failed
to log in to the shelf three
successive times.
Information only.
Loss 8KHz Ref
Clock
The system reference clock was Try reassigning the clock—especially to
lost.
internal. This alarm may also indicate
an STX backplane problem.
Loss 25MHz ATM
Clock
STX hardware failure
Replace the STX card.
Loss BITS Input
Signal
The system BITS clock has
failed.
Correct the BITS clock input.
(continued)
Managing System Alarms
209
Table 41 MCPU and STX Module (System) Alarms (continued)
Alarm
Meaning
Troubleshooting Steps
New Card
Configured
Configuration data for a new
card is uploaded.
Information only. The card was not
stored in the database.
No Upload Image
Found
Cannot find card image to
Download a new code image.
upload. Bad code image. (STX)
PWR Supply 1
Absent
Power supply #1 is missing or
has failed.
Be sure power supply #1 is plugged in.
Replace the power supply with an
operating unit.
PWR Supply 2
Absent
Power supply #2 is missing or
has failed.
Be sure power supply #2 is plugged in.
Replace the power supply with an
operating unit.
PWR Supply 3
Absent
Power supply #3 is missing or
has failed.
Be sure power supply #3 is plugged in.
Replace the power supply with an
operating unit.
PWR Supply 4
Absent
Power supply #4 is missing or
has failed.
Be sure power supply #4 is plugged in.
Replace the power supply with an
operating unit.
PWR Supply 5
Absent
Power supply #5 is missing or
has failed.
Be sure power supply #5 is plugged in.
Replace the power supply with an
operating unit.
PWR Supply 6
Absent
Power supply #6 is missing or
has failed.
Be sure power supply #6 is plugged in.
Replace the power supply with an
operating unit.
Queue 0 Over
Threshold
The congestion threshold for
Queue 0 was exceeded.
Check and correct VC connections.
Check and adjust VI shaper values.
Check and adjust incoming traffic
volume. Check for faulty IMA links
which may reduce traffic handling for a
group.
Queue 1 Over
Threshold
The congestion threshold for
Queue 1was exceeded.
Check and correct VC connections.
Check and adjust VI shaper values.
Check and adjust incoming traffic
volume. Check for faulty IMA links
which may reduce traffic handling for a
group.
Queue 2 Over
Threshold
The congestion threshold for
Queue 2was exceeded.
Check and correct VC connections.
Check and adjust VI shaper values.
Check and adjust incoming traffic
volume. Check for faulty IMA links
which may reduce traffic handling for a
group.
Queue 3 Over
Threshold
The congestion threshold for
Queue 3 was exceeded.
Check and correct VC connections.
Check and adjust VI shaper values.
Check and adjust incoming traffic
volume. Check for faulty IMA links
which may reduce traffic handling for a
group.
Received External
Alarm 1
User defined.
The leads connected to external alarm
1 have changed from the normal
setting.
Received External
Alarm 2
User defined.
The leads connected to external alarm
2 have changed from the normal
setting.
Received External
Alarm 3
User defined.
The leads connected to external alarm
3 have changed from the normal
setting.
(continued)
210
CHAPTER 6: PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING
Table 41 MCPU and STX Module (System) Alarms (continued)
Alarm
Meaning
Troubleshooting Steps
Relay Power Fuse
Failed
Fuse for external alarm relay is
blown, preventing external
alarms from being generated.
Replace the module, or operate with no
external alarm capability.
SAR Initialize Failure Problem with the SAR chip on
the MCPU. MCPU SAR failed
initialization.
Replace the MCPU card.
Shelf Mismatch
The MCPU is not in the same
shelf as it was the last time it
was powered up.
Information only.
System Clock
Reverted
The system clock has reverted
to a higher priority clock.
Information only. This alarm occurs
only if the Clock Mode is set to
Revertive on the System Clock
Configuration menu.
System power up
System is powered up.
Information only.
Write Session Taken A super user has changed a
Information only.
by Super User
read-only session to read-write.
Wrong slot for card The card is not in the correct
slot.
Insert the card into the correct slot.
Managing System Alarms
211
Alarms Common to Several Modules
Table 42 describes major alarms common to several PathBuilder S700 modules.
Table 42 Alarms Common to Several Modules
Alarm
Meaning
Troubleshooting Steps
Alarm Indication
Signal(AIS)
An incoming alarm indication
signal (AIS) indicates a LOS
problem is occurring on the
line upstream of the
equipment connected to this
port.
Check your locally connected
DS3/E3/OC3 equipment, or ask your
service provider to trace the source of
the AIS signal.
Far End Receive
Failure
The far end equipment has a
problem with the signal it is
receiving from the PathBuilder
device.
Check for a defective cable between
the PathBuilder device network
interface port and your service
provider’s network interface unit. An
open transmit line can cause this
condition. Check the LBO setting of the
port.
FEAC Loopback
A DS3 overhead function that Check with your service provider to
allows the system to be
determine the reason for the loopback.
enabled or disabled for
responding to Far End Alarm
Condition commands from the
central office. When enabled,
the DS3 line loopback is put up
upon instruction from the
central office. The system
removes the loopback upon
instruction or after 15 minutes.
Idle Signal
The line has not been
provisioned for service. No data
will pass on a line with an idle
signal.
Check the configuration of the terminal
equipment, or have your service
provider check their equipment and
make sure it is provisioned for service.
In Band Loopback
A loopback is configured on
the port. Loopbacks are for
troubleshooting only and
should not be present under
normal operating conditions.
If you are not troubleshooting the port,
turn off the loopback.
Link Down
Summary informational alarm Information only.
to indicate one or more alarms
on this link are active.
Link Up
Summary informational alarm
to indicate all alarms on the
physical link are cleared.
Information only.
Local Card
Loopback
A loopback is configured on
the port. Loopbacks are for
troubleshooting only and
should not be present under
normal operating conditions.
If you are not troubleshooting the port,
turn off the loopback.
Loss of Cell
Delineation(LOCD)
Loss of cell
delineation—possibly a
framing or timing problem.
Check the reference clock source.
Compare parameters between local
and service provider end. Check the
physical layer.
(continued)
212
CHAPTER 6: PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING
Table 42 Alarms Common to Several Modules (continued)
Alarm
Meaning
Troubleshooting Steps
Loss of Signal(LOS)
Cannot detect a signal at a
configured port. This alarm is
applicable to DS3 UNI, E3 UNI,
OC3/STM-1 UNI, DS1 IMA UNI,
and E1 IMA UNI ports.
Check the cable between the interface
port and the service provider’s
equipment/terminal equipment. Check
cable connections. Check transmit and
receive pairs for proper connection.
Check terminating equipment. Call
your service provider.
Network Card
Loopback
A loopback is configured on
the port. Loopbacks are for
troubleshooting only and
should not be present under
normal operating conditions.
If you are not troubleshooting the port,
turn off the loopback.
Network Line
Loopback
A loopback is configured on
the port. Loopbacks are for
troubleshooting only and
should not be present under
normal operating conditions.
If you are not troubleshooting the port,
turn off the loopback.
Out of Frame(OOF)
AIS alarm is detected. The
configuration settings on the
port are not correct for the
line, or the port configuration
is correct, but the line is
experiencing errors that result
in an alarm.
Verify that the framing format
configured on the port matches the
framing format on the line. Check the
port’s statistics report for evidence of a
bad line; bursts of LCVs could indicate
a timing problem. If connected to local
DS3/E3/OC3 equipment, check that
equipment’s output level to make sure
it is not overdriving the input.
Managing System Alarms
213
DS1/E1 UNI Module Alarms
Table 43 describes the alarms specific to the DS1 UNI and E1 UNI modules.
ATM Forum required alarms are indicated by the notation ATM Forum (R-xxx),
where xxx is the required alarm number.
Table 43 DS1/E1 UNI Module Alarms
Alarm
Meaning
AFA Link Removal
Automatic Frequency
Check the removed link for the CRC
Adjustment - Link removed
errors.
from physical line group due to
error rate in CRC check of
T1/E1 exceeding user specified
rate for a given period of time.
Troubleshooting Steps
Bad IMA ID
A link within the group has
Check the links for proper connection.
received an IMA ID from the far Reconnect if necessary.
end that is different than when
the group was initialized (and
from the other links in the
group). The link with the bad
IMA ID is probably
misconnected.
Bad Link ID
Each IMA group assigns a
Check the links for proper connection.
unique Transmit link ID to each Reconnect if necessary.
link in the group. This link ID
should match the Receive link
ID of the remote end IMA
device. This alarm means that a
link was operating correctly,
but then received a Transmit
link ID already assigned to a
previous link.
A Tx Misconnected alarm is
also generated.
Bad M
The far end frame size M has
changed in an IMA link.
The maximum value for the
frame size on the local device’s
serial card must match the
maximum value for the frame
size of the connected device.
The link with the BAD M is
probably misconnected.
Bad Offset
Far end ICP cell offset has
changed in an IMA link.
Each IMA group assigns a
unique Transmit offset to each
link in the group. This alarm
means that a link was
operating correctly, but then
received a Transmit offset
already assigned to a previous
link.
A Tx Misconnected alarm is
also generated.
(continued)
Check to make sure the maximum
frame size is set to the same value on
the local and remote ends.
Check the links for proper connection.
Reconnect if necessary.
214
CHAPTER 6: PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING
Table 43 DS1/E1 UNI Module Alarms (continued)
Alarm
Meaning
Troubleshooting Steps
BAD SCCI
(3Com Patent
Pending)
Status and Change Control
Check the links for proper connection.
Indication – the content of the Reconnect if necessary.
ICP cells has changed. The far
end ICP cell SCCI in this link
does not agree with the SCCI
of the other links in the group.
Bad Symmetry
The far end group symmetry
has changed in an IMA link.
Remove the link and stop Tx and Rx
data.
Duplicated IMA ID
An IMA group has received an
IMA ID that has been received
by a previous group. The
second group must have a
unique IMA ID.
Check for loops and check the IMA
group configuration.
Duplicated Link ID
Duplicated far end logical link
ID in this IMA group for this
IMA link.
Check the links for proper connection.
Reconnect if necessary.
Each IMA group assigns a
unique Transmit link ID to each
link in the group. This link ID
should match the Receive link
ID of the remote end IMA
device. This alarm means that a
link received a Transmit link ID
already assigned to a previous
link.
Duplicated Offset
Duplicated far end ICP cell
offset in this IMA group in an
IMA link.
Check the links for proper connection.
Reconnect if necessary.
Each IMA group assigns a
unique Transmit offset to each
link in the group. This alarm
means that a link received a
Transmit offset already
assigned to a previous link.
Some of the links are probably
misconnected.
Excessive Link Delay The link has exceeded the
user-selectable value for
acceptable link delay.
The link is removed from the
group.
Check the links for proper connection.
Reconnect if necessary. Also try
adjusting the link delay parameter for
the IMA group.
Group [n] Abort
Symmetry
Generated when Group [n]
Config. Abort is generated,
due to group symmetry
problem
Check and correct near end symmetry.
Only symmetric operation is supported
in PathBuilder products.
Group [n] Config
Abort
The near end node rejects the
far end IMA parameters.
Check and correct the near end and far
end parameters for compatibility.
ATM Forum (R-128)
Group [n] Degraded The IMA group is passing data
Service
with less than the number of
IMA links you configured.
(continued)
Continue passing data. Correct faulty
links or adjust IMA group
configuration.
Managing System Alarms
215
Table 43 DS1/E1 UNI Module Alarms (continued)
Alarm
Meaning
Group [n] Dup. IMA The same group IMA ID has
ID
been received on links
belonging to different IMA
groups in the same card.
Troubleshooting Steps
Correct link or group configuration.
Group [n] FE Abort
Symmetry
The far end rejects the
Check and correct near end symmetry.
symmetry sent by the near end. Only symmetric operation is supported
in PathBuilder products.
Group [n] FE
Blocked
The far end reports it is not
passing data.
Check and repair link facilities. Verify
configuration.
ATM Forum (R-132)
Group [n] FE Config The far end rejects the M value Configure both ends to the same M
Abort
used by the near end.
value.
NOTE: This alarm should not occur if
both ends are PathBuilder S310, S330,
S600, or S700 products.
Group [n] FE Start
Up
The far end is coming up
(starting IMA).
Information about far end state.
ATM Forum (R-127)
Group [n] FE
Insufficient Links
The far end node is reporting
Check and repair link facilities. Verify
an insufficient number of links. configuration.
ATM Forum (R-131)
Group [n]
Insufficient Links
The near end finds not enough Check and correct any faulty IMA links.
available links.
Check and correct IMA minimum links
parameter.
ATM Forum (R-130) This occurs when the near end
has completed parameter
negotiation with the far end,
but is neither passing data nor
blocked.
Group [n] Lack of
Link
The near end is idling because
it does not have enough links
in an IMA group. This occurs
only after group parameters
are negotiated. When this
occurs, the “NE Insufficient
Links” alarm is also reported.
Group [n] Link
Down
Summary information alarm to Information only.
indicate one or more alarms on
this IMA group are active.
Group [n] Link Up
Summary informational alarm
to indicate all alarms on the
IMA group are cleared.
Group [n] N<P
There are fewer configured
Continue passing data.
links than IMA links required to
make an IMA group active.
Group [n] No Link
The near end has lost all its
If one or more links comes back,
links in an IMA group because re-identify the link(s) and renegotiate
these links have AFA, LOS, AIS, parameters with the far end group.
OOF, LCD, or missing ICP cells.
This invalidates all the far end
identity.
(continued)
Take the group down, and stop passing
data in all links.
Information only.
216
CHAPTER 6: PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING
Table 43 DS1/E1 UNI Module Alarms (continued)
Alarm
Meaning
Group [n] Multi
IMA ID
Different group IMA ID
Correct link connections and/or IMA
received on different links in an group configuration.
IMA group.
Group [n] Multi Test Different test procedure
request from different links in
ATM Forum (R-138)
an IMA group from the far
end.
Troubleshooting Steps
Use the test procedure from the lowest
logical link and ignore the other test
procedures.
Group [n] Multiple
M
Different frame lengths
Make sure that the IMA frame length is
received on different links in an set to the same value for all links.
IMA group.
Group [n] Multiple
Symmetry
Different group symmetry
received on different links in an
IMA group (symmetrical versus
asymmetrical operation).
Group [n] Time
Sync Fail
The far end transmit clocking
Check configuration. Only CTC
mode does not match the near (Common Transfer Clock) is supported.
end transmit clocking mode
If the far end transport clocking is set to
ITC (Independent Transfer Clock),
change it to CTC.
IMA Protocol
Mismatch
IMA label is not ATM Forum
1.0.
Near end and far end IMA protocol
versions do no match. Check and
correct incompatibility.
IMA Remote
Loopback
Far end loopback detected,
external cable loopback or
crosstalk.
Remove loopback condition.
IMA Tx
Misconnected
The near end IMA networking
Tx or Rx link state machine
detects the link is not
ATM Forum (R-123)
connected to the correct FE Tx
or Rx links.
Configure the group to be symmetric.
3Com PathBuilder products do not
support asymmetric bandwidth for
IMA.
Remove the link and stop Tx and Rx
data.
Loss of Differential
Synchronization
(LODS)
Relative time difference
Have your carrier verify the time synch
between individual T1s/E1s in and routing of individual T1s/E1s in the
the IMA group is out of range. group. Check the IMA group
configuration to ensure consistency on
ATM Forum (R-122) LODS is declared after the Rx
the local and remote ends.
IMA fails to synchronize the
IMA link(s) in an IMA group
within some time limit.
Loss of IMA Frame
(LIF)
ATM Forum (R-121)
Loss of IMA Frame is detected
in the Rx direction for an IMA
link UP.
There is an IMA frame size
mismatch between two ends
of the circuit. This can be
caused by missing ICP cells
(ATM cells that carry protocol
information), bad IMA ID, bad
sequence number, bad M, bad
offset HEC error or CRC error
in ICP cells. This problem may
occur if the link gets noisy and
there is no AFA to prevent the
ICP from getting corrupted. It
is detected in hardware and
may or may not cause an
operational problem.
(continued)
Check the IMA group configuration to
ensure consistent frame size on the
local and remote ends. Check links for
evidence of noise. Check to be sure
that AFA is enabled.
Managing System Alarms
217
Table 43 DS1/E1 UNI Module Alarms (continued)
Alarm
Meaning
Troubleshooting Steps
Port Missing ICP
Cells
Two consecutive ICP cells
missing from the IMA frame.
See also Loss of IMA Frame (LIF). This is
a specific cause of that alarm and will
also be reported.
RFI IMA
Remote Failure Indication: Far
end IMA Rx networking link
state machines detected LOS,
OOF, AIS. LCD, LIF or LODS.
Correct T1 or E1 facilities error.
Test Pattern Failed
An 8-bit pattern is sent to the
remote node which must then
echo it back on all ports. The
local node checks the echoed
pattern and reports an alarm if
cells from one or more of the
links fail to arrive. This alarm is
declared on all links which do
not reply or reply incorrectly.
Make sure that the same number of
links are configured and enabled on
both ends of the IMA configuration.
Make sure that the configuration of
both groups is the same. For instance,
make sure that the payload scrambling
setting is the same on both ends.
Yellow Alarm
OOF alarm is detected. A
received remote alarm
indication means that the far
end equipment has a problem
with the signal it is receiving
from the PathBuilder device.
Connect an external loopback cable to
the port. If there are no alarms, the
problem is elsewhere. Check for an
open, short, or wiring error in the cable
between the PathBuilder network
interface port and your service
provider's network interface unit, or
the terminal equipment. An open
transmit pair can cause this condition
ATM Forum (R-121)
218
CHAPTER 6: PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING
DSX-1/E1 CBR Module Alarms
Table 44 describes the alarms specific to DSX-1 and E1 CBR modules.
.
Table 44 DSX-1/E1 CBR Module Alarms
Alarm
Meaning
Troubleshooting Steps
Cellbus parity
Parity error on cells received
from cell bus.
Check VC and port configuration.
E1 Loss of CAS
Multiframe
E1 signaling multiframe
alignment has been lost.
Check the physical connection and the
carrier for configuration problems.
E1 Time Channel 16 All 1s in E1 time slot 16 for 2
AIS Rcv
consecutive frames.
Make sure both the local device and
the far end device are configured for
Time Slot 16 framing. If both devices
are correctly configured, there may be
a hardware problem in either device.
Far End E1 Loss of
CAS
The far end device has lost
Check the E1 configuration of the far
Channel Associated Signalling. end device.
HP cellbus
congested
High priority cell bus
congested.
The cell port has been
configured to pass more CBR
traffic than it can physically
handle. The aggregate
bandwidth of the CBR
connections exceeds the total
bandwidth of the port. This
alarm indicates that you either
mistakenly oversubscribed the
cell port with CBR connections,
or more connections than
expected are simultaneously
active. When this condition
exists on the HP cell bus, lower
priority cell busses will not be
able to pass traffic out.
Remove high priority connections until
the configured bandwidth is less than
or equal to the total bandwidth on the
port. If you have over-subscribed the
port and all high priority devices are
using the connections, turn off some
devices.
LP cellbus
congested
Low priority cell bus congested. Remove low priority connections until
the configured bandwidth is less than
or equal to the total bandwidth on the
port. If you have over-subscribed the
port and all low priority devices are
using the connections, turn off some
devices.
MP cellbus
congested
Medium priority cell bus
congested.
Receive FIFO
Overflow
Cells are being received from
Reconfigure the CBR connection so
the cell bus faster than the CBR that it has adequate bandwidth.
can process them.
SAR SRAM failure
SAR SRAM failure (applicable
to CBR)
(continued)
Remove medium priority connections
until the configured bandwidth is less
than or equal to the total bandwidth
on the port. If you have oversubscribed the port and all medium
priority devices are using the
connections, turn off some devices.
Replace the STX card.
Managing System Alarms
219
Table 44 DSX-1/E1 CBR Module Alarms (continued)
Transmit FIFO
Overflow
The cell bus is congested, and The entire CBR connection must be
cells are backed up on the CBR. synchronous end-to-end. Make sure
the clock rates of the devices at either
Traffic at the output side of the
end of the connection match each
CBR port is being transmitted
other and match the transmit clock rate
more slowly than it is being
of the CBR ports on the PathBuilder
received from the cell bus. As a
device.
result, the output buffer is
overflowing. In general, the
problem is that the CBR
connection is not synchronized
end-to-end. The clock rate of
the output port does not
match the clock rate of the
device from which the traffic
originated.
VC RDI Receive
VC RDI (Remote Defect
Indication) OAM received in
the connection. The far end
equipment has a problem with
the signal it is receiving,
indicating that the problem lies
between the network provider
and the far end terminal
equipment for this connection.
Check for a defective cable between
the far end interface port and your
service provider's network interface
unit. An open transmit line can cause
this condition.
QSIM/FAM Alarms
Table 45 describes the alarms specific to QSIMs and FAMs
Table 45 QSIM Alarms
Working with History
Alarms
Alarm
Meaning
Troubleshooting Steps
LMI Link Down
The Local Management
Interface has taken the link
down.
Check the LMI protocol configuration
for the port.
The PathBuilder S700 captures all alarms and information events and keeps them
in an alarm history file. This file can hold up to 300 events; it fills on a
first-in/first-out basis. We recommend that you routinely view the alarm history file
before events are lost. We also recommend that you print the file for comparison
with previous history files and entry into your maintenance log.
Viewing and Printing History Alarms
To view and print an alarm history, follow these steps:
1 From the Main menu, select [3] Fault Management to display the Fault
Management menu shown earlier in Figure 163.
2 Select [3] Display History Alarms to view the alarm history. Figure 165 shows a
representative Display History Alarm screen.
220
CHAPTER 6: PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING
Figure 165 Display History Alarm Screen
If the history file cannot be displayed on one page, the Display History Alarm
screen will include a prompt to press [N] for the next page and press [P] for the
previous page.
3 Use the print screen or other printing feature of your NMS station to print out
each page of the history file.
4 Compare the printouts to your most previous records to see if there are any
obvious trends, such as more frequent alarms of a certain type, which might
require troubleshooting.
Clearing History Alarms
After you have printed the alarm history, you should clear the alarms so that they
will no longer take up space in the alarm history file. To do this, follow these steps:
1 Return to the Fault Management menu.
2 Select [4] Clear History Alarms. The following prompt appears:
Do you want to clear history alarms (Y/N) [N]?
3 Enter y to clear the history alarms.
Using Loopbacks
Loopbacks allow you to check circuit continuity between one point and another.
You should use the PathBuilder loopback feature to check continuity to the
nearest point first, and if the circuit is valid to that point, then loop to the next
point. If a circuit has been compromised, isolating the problem between two
points should help you identify and resolve the problem.
To access the loopback modes supported by the PathBuilder S700, follow these
steps:
1 From the Main menu, select [3] Fault Management to display the Fault
Management menu shown earlier in Figure 163.
2 Select [5] Loopback from the Fault Management menu to display the Loopback
menu, shown in Figure 166.
Using Loopbacks
221
Figure 166 Loopback Menu
3 Select the card type for which you want to conduct the loopback.
If you select a DS1/E1 UNI or a DSX-1/E1 CBR card, you must configure the
loopback on a per-port basis. After you select the card type, a port selection menu
appears. In order to access the Loopback menu for that card, you must select a
port from this menu
The Loopback menu for the selected card appears. Figure 167 shows the
Loopback menu for the DS3 UNI card.
If you select a card type for which the PathBuilder S700 does not support
loopbacks, a message appears, informing you that no loopback feature is available
for that card type.
Figure 167 DS3 UNI Loopback Menu
4 Select [1] Set Loopback. A prompt listing the loopback choices for the selected
port appears at the bottom of the screen.
222
CHAPTER 6: PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING
5 Enter the number corresponding to the type of loopback you want to configure.
The Loopback menu for the selected card type now lists the type of loopback you
have selected.
The following subsections describe the available loopbacks for each of the
PathBuilder S70000 interfaces.
DS3 UNI Module
Loopbacks
The DS3 UNI module supports the following loopbacks:
Local Card—Loops the transmit DS3 output on the receive side. All cells coming
from the DS3 card are looped through the backplane and back to the DS3 card.
The transmitted data will continue to go on the output.
Network Line—Loops the DS3 received data back on the output side after the
digital data has been recovered.
Network Card—Loops the DS3 received cell payload back toward the line output.
Figure 168 illustrates the DS3 loopback options.
Figure 168 DS3 UNI Loopback Options
DS3 Interface
Network Side
Bus Side
Network Card
Network
Line
E3 UNI Module
Loopbacks
Local Card
The E3 UNI module supports the following loopbacks:
Local Card—Loops the transmit E3 output on the receive side. All cells coming
from the E3 port card are looped through the backplane and back to the E3 port
card. The transmitted data will continue to go on the output.
Network Line—Loops the E3 received data back on the output side after the
digital data has been recovered.
Network Card—Loops the E3 received cell payload back toward the line output.
Using Loopbacks
223
Figure 169 illustrates the loopbacks for the E3 module.
Figure 169 E3 Loopback Options
E3 Interface
Network Side
Network Card
Local
Line
Payload
OC3/STM-1 UNI Module
Loopbacks
The OC3/STM-1 UNI module supports the following loopbacks:
Local Card—Loops the transmit OC3/STM-1 output on the receive side. All cells
coming from the OC3/STM-1 port card are looped through the backplane and
back to the OC3/STM-1 port card. The transmitted data will continue to go on the
output.
Network Line—Loops the OC3/STM-1 received data back on the output side
after the digital data has been recovered.
Figure 170 illustrates the loopbacks for OC3.
Figure 170 OC3/STM-1 Loopback Options
OC3 Interface
Network Side
Local Card
Network Line
Payload
224
CHAPTER 6: PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING
DSX-1 CBR Module
Loopbacks
The DSX-1 CBR module supports the following loopbacks:
Local Card—Loops the transmit DSX-1 output on the receive side. All cells coming
from the DSX-1 CBR port card are looped through the backplane and back to the
DSX-1 CBR port card. The transmitted data will continue to go on the output
towards the trunk card.
Network Line—Loops the DSX-1 received data back on the output side after the
digital data has been recovered.
Network Card—Loops the DSX-1 received payload back toward the line output.
Figure 171 illustrates the DSX-1 CBR loopback options.
Figure 171 DSX-1 CBR Loopback Options
CBR DSX Interface
Line Side
ATM Side
(Trunk)
Network Line
Network Card
Local Card
FAM Loopbacks
The FAM module supports the following loopbacks:
Local Card—Loops the transmit FAM output on the receive side. All cells coming
from the FAM port card are looped through the backplane and back to the FAM
port card. The transmitted data will continue to go on the output towards the
trunk card.
Network Line—Loops the DS1 received data back on the output side after the
digital data has been recovered.
Network Card—Loops the DS1 received payload back toward the line output.
Viewing Statistics
225
Figure 172 illustrates the FAM loopback options.
Figure 172 FAM Loopback Options
FAM Interface
Line Side
ATM Side
(Trunk)
Network Line
Network Card
Local Card
DS1/E1 UNI with IMA
Module Loopbacks
The DS1 UNI and E1 UNI with IMA modules supports the following loopbacks:
Network Line—The DS1 framer loops back all the bits received from the
network.
Network Card—The DS1 framer loops back the payload from the network.
Local Card—The DS1 framer loops back the payload to the local cell bus.
Viewing Statistics
You can view two basics types of statistics for the various cards installed in the
PathBuilder S700 shelf:
n
Card statistics
n
Virtual circuit statistics
This section gives you an overview of these types of statistics, tells you how to
view the statistics screens, and defines the statistics listed on each of the statistics
screens.
Card Statistics Overview
The PathBuilder S700 supports two types of card statistics:
n
Performance statistics
n
ATM statistics
Performance Statistics Overview
Performance monitoring screens list statistics that reflect the physical monitoring
of the line. You can view the following types of performance monitoring statistics
for each card:
Current—The statistics being collected for the current 15-minute interval.
226
CHAPTER 6: PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING
Interval—The statistics collected over the previous 24 hours of operation, broken
into 96 completed 15-minute intervals. The intervals are numbered, and, if
available, statistics are listed for each of the 96 intervals.
Total—The cumulative sum of the various statistics for the 24-hour period
preceding the current 15-minute interval.
Figure 173 shows a representative performance monitoring screen.
Figure 173 DS3 UNI Interval Performance Monitoring Screen
ATM Statistics Overview
ATM screens list statistics that monitor the ATM payload. ATM cell statistics are cell
counts since the last counter reset. On the ATM Statistics screen, you can reset the
counter by entering [c]. ATM statistics are displayed as a list rather than a table.
Figure 174 shows a representative ATM statistics screen.
Figure 174 DS3 UNI ATM Statistics Screen
Viewing Statistics
Virtual Circuit Statistics
Overview
Viewing Card Statistics
227
You can view the following types of virtual circuit statistics—either by circuit or by
port/group:
n
A summary of statistics for all virtual circuits
n
A detailed list of statistics for a specific circuit
To view card statistics, follow these steps:
1 From the Main menu, select [4] Performance Management to open the
Performance Management menu, shown in Figure 175.
Figure 175 Performance Management Menu
2 Select [1] Show Card Statistics to open the Card statistics menu, shown in
Figure 176.
Figure 176 Card Statistics Menu
228
CHAPTER 6: PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING
3 Enter the number corresponding to the card for which you want to view statistics
to open the Performance Management menu for that card. Figure 177 shows the
OS3/STM-1 UNI Performance Management menu.
If you select a card with multiple ports, you must also select the port for which you
want to view statistics. After you select the card type, a port selection menu
appears. In order to access the Performance Management menu for that card, you
must select a port from this menu.
If you select a for which no performance statistics are available, you will get a
message to that effect.
Figure 177 OC3/STM-1 UNI Performance Management Menu
4 Enter the number corresponding to the type of statistics you want to view to open
the corresponding statistics screen. The available statistics vary, depending on the
card type.
If you select a performance monitoring option instep 4, the Performance
Monitoring menu appears. Enter the number corresponding to the type of data
you want to view: current, interval, or total. You can also select [4] Clear All PM
Data from the Performance Monitoring menu to clear all the performance
monitoring data.
For descriptions of the statistics available on specific PathBuilder S700 card
statistics screens, see the following subsections.
Viewing DS3 UNI Module Statistics
You can view the following types of statistics for the DS3 UNI Module:
n
DS3 UNI Performance Monitoring (physical monitoring of the line)
n
ATM Statistics (monitoring of the ATM payload)
Viewing Statistics
229
DS3 UNI Performance Monitoring The DS3 Performance Monitoring screen
displays the following statistics:
PES—The number of P-bit errored seconds (PESs) encountered by the DS3
interface.
PSES—The number of P-bit severely errored seconds (PSESs) encountered by the
DS3 interface.
SEFS—The number of severely errored framing seconds (SEFSs) encountered by
the DS3 interface.
UAS—The number of unavailable seconds (UASs) encountered by the DS3
interface.
LCV—The number of line coding violations (LCVs) encountered by the DS3
interface.
PCV—The number of path coding violations (PCVs) encountered by the DS3
interface.
LES—The number of line errored seconds (LESs) encountered by the DS3
interface.
CCV—The number of C-bit coding violations (CCVs) encountered by the DS3
interface.
CES—The number of C-bit errored seconds (CESs) encountered by the DS3
interface.
CSES—The number of C-bit severely errored seconds (CSESs) encountered by the
DS3 interface.
DS3 ATM Statistics The DS3 UNI ATM Statistics screen displays the following
statistics:
Cells Received—The number of ATM cells received on the DS3 since the last user
reset of this counter.
Cells transmitted—The number of ATM cells transmitted on the DS3 since the
last user reset of this counter.
Cells dropped—The number of idle/unassigned cells encountered and dropped
on the interface.
Cells with HCS errors—The number of header check sequence (HCS) errored
cells encountered on the ATM interface.
Viewing E3 UNI Module Statistics
You can view the following types of statistics for the E3 UNI Module:
n
E3 UNI Performance Monitoring (physical monitoring of the line)
n
ATM Statistics (monitoring of the ATM payload)
E3 UNI Performance Monitoring The E3 Performance Monitoring screen
displays the following statistics:
SEFS—The number of severely errored framing seconds (SEFSs) encountered by
the E3 interface.
LCV—The number of line coding violations (LCVs) encountered by the E3
interface.
LES—The number of line errored seconds (LESs) encountered by the E3 interface.
230
CHAPTER 6: PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING
E3 ATM Statistics ATM cell statistics are cell counts since the last counter reset.
On the ATM Statistics screen, you can reset the counter by entering [c]. ATM
statistics are displayed as a list rather than a table, as shown earlier in Figure 174.
The E3 UNI ATM Statistics screen displays the following statistics:
Cells Received—The number of ATM cells received on the E3 since the last user
reset of this counter.
Cells transmitted—The number of ATM cells transmitted on the E3 since the last
user reset of this counter.
Cells dropped—The number of idle/unassigned cells encountered and dropped
on the interface.
Cells with HCS errors—The number of header check sequence (HCS) errored
cells encountered on the ATM interface.
Viewing OC3/STM-1 UNI Module Statistics
You can view the following types of statistics for the OC3/STM-1 UNI Module:
n
OC3/STM-1 UNI Performance Monitoring (physical monitoring of the line)
n
ATM Statistics (monitoring of the ATM payload)
OC3/STM-1 UNI Performance Statistics You can view the following types of
OC3/STM-1 performance statistics:
n
section
n
line
n
far line
n
path
n
far path
OC3/STM-1 UNI Section Performance Monitoring
ES—The number of errored seconds (ESs) encountered by the OC3/STM-1 section.
SES—The number of severely-errored seconds (SESs) encountered by the
OC3/STM-1 section.
SEFS—The number of severely errored framing seconds (SEFSs) encountered by
the OC3/STM-1 section.
CVS—The number of coding violations (CVs) encountered by the OC3/STM-1
section.
LOS—The number of Loss of Signal (LOS) conditions encountered by the
OC3/STM-1 section.
LOF—The number of Loss of Frame (LOF) conditions encountered by the
OC3/STM-1 section.
OC3/STM-1 UNJ Line Performance Monitoring
ES—The number of errored seconds (ESs) encountered by the OC3/STM-1 line.
SES—The number of severely-errored seconds (SESs) encountered by the
OC3/STM-1 line.
Viewing Statistics
231
UAS—The number of unavailable seconds (UASs) encountered by the OC3/STM-1
line.
CVS—The number of coding violations (CVs) encountered by the OC3/STM-1 line.
AIS—The number of Alarm Indicator Signal (AIS) conditions encountered by the
OC3/STM-1 line.
RDI—The number of Remote Defect Indication (RDI) conditions encountered by
the OC3/STM-1 interface. Also known as FERF (Far End Receive Failure). This is the
alarm that is generated when a far end AIS or LOP defect is detected.
OC3/STM-1 UNI Far Line Performance Monitoring
ES—The number of far end errored seconds (ESs) encountered by the OC3/STM-1
interface.
SES—The number of far end severely-errored seconds (SESs) encountered by the
OC3/STM-1 interface.
UAS—The number of far end unavailable seconds (UASs) encountered by the
OC3/STM-1 interface.
CVS—The number of far end coding violations (CVs) encountered by the
OC3/STM-1 interface.
OC3/STM-1 UNI Path Performance Monitoring
ES—The number of errored seconds (ESs) encountered by the OC3/STM-1 path
interface.
SES—The number of severely-errored seconds (SESs) encountered by the
OC3/STM-1 path interface.
UAS—The number of unavailable seconds (UASs) encountered by the OC3/STM-1
path interface.
CVS—The number of coding violations (CVs) encountered by the OC3/STM-1 path
interface.
LOP—The number of Loss of Pointer (LOP) conditions encountered by the
OC3/STM-1 path interface.
AIS—The number of Alarm Indicator Signal (AIS) conditions encountered by the
OC3/STM-1 path interface.
RDI—The number of Remote Defect Indication (RDI) conditions encountered by
the OC3/STM-1 path interface. Also known as FERF (Far End Receive Failure). This
is the alarm that is generated when a far end AIS or LOP defect is detected.
UEQ—The number of Unequipped (UEQ) conditions encountered by the
OC3/STM-1 path interface. If a path is not provisioned (i.e. it is idle), the SONET
equipment will signal this state.
PLM—Physical Layer Module.
OC3/STM-1 UNI Far Path Current Performance Monitoring
ES—The number of far end errored seconds (ESs) encountered by the OC3/STM-1
path interface.
SES—The number of far end severely-errored seconds (SESs) encountered by the
OC3/STM-1 path interface.
232
CHAPTER 6: PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING
UAS—The number of far end unavailable seconds (UASs) encountered by the
OC3/STM-1 path interface.
CVS—The number of far end coding violations (CVs) encountered by the
OC3/STM-1 path interface.
OC3/STM-1 UNI ATM Statistics The OC3/STM-1 UNI ATM Statistics screen
displays the following statistics:
Cells Received—The number of ATM cells received on the OC3/STM-1 since the
last user reset of this counter.
Cells transmitted—The number of ATM cells transmitted on the OC3/STM-1
since the last user reset of this counter.
Cells dropped—The number of idle/unassigned cells encountered and dropped
on the interface.
Cells with HCS errors—The number of header check sequence (HCS) errored
cells encountered on the ATM interface.
Viewing DS1 UNI and E1 UNI with IMA Module Statistics
You can view DS1 UNI and E1 UNI statistics for ports or for groups.
To view statistics for a DS1 UNI or E1 UNI with IMA module, follow these steps:
1 From the Card Statistics menu, shown earlier in Figure 176, select the option
corresponding to the DS1 UNI or E1 UNI card to open the DS1/E1 UNI Performance
menu.
2 Select [1] Port/Link Performance Management to view port statistics or [2] Group
Performance Management to view group statistics.
3 Enter the number corresponding to the port or group for which you want to view
statistics.
4 Select the option corresponding to the type of statistics you want to view.
n
n
Port statistics
n
Physical performance
n
IMA link performance
n
IMA link ATM
Group statistics
n
Group performance
n
Group ATM
If you select a performance monitoring option, you need to select the type of data
you want to view (current, interval, or total; for this release current data is your
only option) from an intermediary screen before the performance statistics for the
selected group or port are displayed. You can also clear the performance statistics
from this intermediary screen.
The following sections list the specific counters listed for each type of DS1/E1 UNI
statistic.
Viewing Statistics
233
DS1 UNI and E1 UNI Port/Link Physical Performance Statistics The DS1/E1
UNI Performance Monitoring screens display the following current, interval, or
total statistics:
ES—The number of errored seconds (ESs) encountered by the T1/E1 interface.
SES—The number of severely-errored seconds (SESs) encountered by the T1/E1
interface.
SEFS—The number of severely errored framing seconds (SEFSs) encountered by
the T1/E1 interface.
UAS—The number of unavailable seconds (UASs) encountered by the T1/E1
interface.
CSS—The number of controlled slip seconds (CSSs) encountered by the T1/E1
interface.
PCV—The number of path coding violations (PCVs) encountered by the T1/E1
interface.
LES—The number of line errored seconds (LESs) encountered by the T1/E1
interface.
BES—The number of bursty errored seconds (BESs) encountered by the T1/E1
interface.
DM—The number of degraded minutes (DM) encountered by the T1/E1 interface.
LCV—The number of line coding violations (LCVs) encountered by the T1/E1
interface.
You can view the statistics as current, interval, or total data.
DS1 UNI and E1 UNI Port/Link IMA Link Performance Statistics The DS1/E1
IMA Link Performance Monitoring screen lists the following statistics:
IMA Violation (IV-IMA)—Number of errored, invalid, or missing ICP cells.
NE Severe Errored Sec (SES-IMA)—Near end severely-errored seconds; the
number of seconds with IMA violation, LOS, AIS, OOF, LCD, LIF, LODS at the near
end.
FE Severe Errored Sec (SES-IMA-FE)—Far end severely-errored seconds; the
number of seconds with IMA violation, LOS, AIS, OOF, LCD, LIF, LODS at the far
end.
NE Unavailable Sec (UAS-IMA)—Near end unavailable seconds; the number of
unavailable seconds at the near end.
FE Unavailable Sec (UAS-IMA-FE)—Far end unavailable seconds; the number of
unavailable seconds at the far end.
NE Tx Unusable Sec (Tx-UUS-IMA)—Near end transmit unusable seconds; the
number of unusable seconds at the near end interworking Tx link state machine.
NE Rx Unusable Sec (Rx-UUS-IMA)—Near end receive unusable seconds; the
number of unusable seconds at the near end interworking Rx link state machine.
FE Tx Unusable Sec (Tx-UUS-IMA-FE)—Far end transmit unusable seconds; the
number of unusable seconds at the far end interworking Tx link state machine.
FE Rx Unusable Sec (Rx-UUS-IMA-FE)—Far end receive unusable seconds; the
number of unusable seconds at the far end interworking Rx link state machine.
234
CHAPTER 6: PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING
NE Tx Number of Failures (Tx-FC)—Number of Tx failure alarms at the near end.
NE Rx Number of Failures (Rx-FC)—Number of Rx failure alarms at the near
end.
FE Tx Number of Failures (Tx-FC-FE)—Number of Tx failure alarms at the far
end.
FE Rx Number of Failures (Rx-FC-FE)—Number of Rx failure alarms at the far
end.
DS1 UNI and E1 UNI Port/Link IMA Link ATM Statistics The T1/E1 Link ATM
Statistics screen lists the following statistics:
Tx Cells—The number of Tx data cells since the counter was cleared.
Rx Cells—The number of Rx data cells since the counter was cleared.
Rx ICP Cell Error—Number of Rx errored ICP cells since the counter was cleared.
Tx Cell Rate—Current Tx cells per second.
Rx Cell Rate—Current Rx cells per second.
Rx ICP Cell Error Rate—Current Rx errored ICP cells per second.
Avg. Tx Cell Rate—Average Tx data cells rate calculated over the last 8 seconds.
Avg. Rx Cell Rate—Average Rx data cells rate calculated over the last 8 seconds.
Avg. Rx ICP Cell Err Rate—Average Rx errored ICP cells rate calculated over the
last 8 seconds.
DS1 UNI and E1 UNI Group Performance Statistics The T1/E1 Group
Performance screen lists the following statistics:
Running Sec—Count of operational seconds at the near end interworking group
state machine.
Unavailable Sec—Count of unavailable seconds at the near end interworking
group state machine.
NE Number of Failures—Number of failure alarms at the near end.
FE Number of Failures—Number of failure alarms at the far end.
DS1 UNI and E1 UNI Group ATM Statistics The T1/E1 Group ATM Statistics
screen lists the following statistics:
Tx Cells—The number of Tx data cells since the counter was cleared.
Rx Cells—The number of Rx data cells since the counter was cleared.
Rx ICP Cell Error—Number of Rx errored ICP cells since the counter was cleared.
Tx Cell Rate—Current Tx cells per second.
Rx Cell Rate—Current Rx cells per second.
Rx ICP Cell Error Rate—Current Rx errored ICP cells per second.
Avg. Tx Cell Rate—Average Tx data cells rate calculated over the last 8 seconds.
Avg. Rx Cell Rate—Average Rx data cells rate calculated over the last 8 seconds.
Avg. Rx ICP Cell Err Rate—Average Rx errored ICP cells rate calculated over the
last 8 seconds.
Viewing Statistics
235
Viewing Ethernet Module Statistics
You can view the following types of statistics for the Ethernet Modules:
n
Bridging and Ethernet Statistics (per port)
n
Spanning Tree Statistics
n
ATM VC Statistics
Bridging and Ethernet Statistics The Bridging and Ethernet Statistics screen
displays the following statistics:
n
Bridge statistics
n
Filtering statistics
n
Ethernet statistics
Bridge Statistics
Port state—The operational state of the Ethernet bridged port, based on the
802.1D specification: disabled, listening, learning, forwarding, or blocking.
Total frames received—The total number of frames received at this port.
Broadcast Frames—The number of broadcast frames received on the port.
Spanning Tree Frames—The total number of 802.1D Bridge Protocol Data Unit
frames received by the bridged port since the statistics were last cleared.
Discarded Frames—The number of valid frames received that were discarded
(filtered) by the forwarding process.
Flooded Frames—The total number of incoming frames that were flooded on
this port.
Forwarded Frames—The number of incoming frames at this port that were
forwarded.
Total frames transmitted—The total number of frames transmitted at this port.
Filtering Statistics
MAC MTU Exceeded—The number of frames discarded because of a size greater
than the maximum MTU size for the port.
No ATM VCs present—The number of frames discarded because there was no
ATM VC associated with the physical port.
Bridge discards—The number of frames discarded due to the bridging operation.
Output port disabled—The number of frames discarded because the output
port was disabled.
Source address filtered—The number of frames discarded due to source address
filtering.
Destination address filtered—The number of frames discarded due to
destination address filtering.
SAP Filtered—The number of frames discarded due to the protocol filtering
operation.
236
CHAPTER 6: PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING
Ethernet Statistics
Transmitted frames—The total number of frames transmitted at this port.
Transmitted bytes—The total number of bytes transmitted at this port.
Received frames—The total number of frames received at this port.
Received bytes—The total number of bytes received at this port.
CRC errored frames—The number of frames with CRC errors detected at this
port.
Deferred transmits—The number of frames for which the first transmission
attempt at this port was delayed because the port was busy. This count does not
include frames involved in collisions.
Single collisions—The number of successfully-transmitted frames at this port for
which transmission is inhibited by exactly one collision.
Multiple collisions—The number of successfully-transmitted frames at this port
for which transmission is inhibited by more than one collision.
Late collisions—The number of times that a collision has been detected on this
port later than 512 bit-times into the transmission of a packet.
Excessive collisions—The number of frames for which transmission at this port
failed due to excessive collisions.
Carrier sense errors—The number of times that the carrier sense condition was
lost or never asserted when attempting to transmit a frame at this port.
Internal transmit errors—The number of frames for which reception at this port
failed due to an internal MAC sublayer receive error.
Oversized frames—The number of frames received at this port that exceeded
the maximum permitted frame size.
Alignment Errors—The total number of alignment errors detected for the
bridged physical port since the statistics were last cleared.
Spanning Tree Statistics The Spanning Tree Statistics screen displays the
following statistics:
Bridge Identifier—The bridge address of the Ethernet port.
Root Bridge—The bridge root address of the Ethernet port.
Designated Bridge ID—The designated Spanning Tree bridge ID of this port.
Hello Time—The time interval between issuing STP (Spanning Tree Protocol)
configuration messages.
Forward Delay—The amount of time in the “learning” and “listening” states;
half the amount of time that must elapse between the time when it is decided
that a port should become part of the Spanning Tree and the time when data
traffic is allowed to be forwarded to and from that port.
Maximum Age—The time at which a configuration message is discarded.
Port Identifier—The bridge root port of the Ethernet port.
Root Path Cost—The bridge root path cost of the Ethernet port.
Designated Port ID—The designated Spanning Tree bridge port ID of this port.
Topology Changed—The topology change state of Spanning Tree for this port.
Viewing Statistics
237
Topology Changed Count—The number of topology changes of Spanning Tree
for this port.
Total Forward Transitions—The total number of state transitions to a
forwarding state since the statistics were last cleared.
Total BridgeUp Time—The total amount of time, in seconds, that the bridge has
been active with Spanning Tree enabled. This count is valid only when Spanning
Tree is enabled for a bridged port.
ATM VC Statistics The ATM VC Statistics screen displays the following statistics:
VC#—The system-assigned virtual circuit number.
(Side A) card s/p—The slot and port number for side A of the circuit.
(Side A) rx—The receive VCI/VPI for side A.
(Side A) tx—The transmit VCI/VPI for side A.
(Side B) card s/p—The slot and port number for side B of the circuit.
(Side B) rx—The receive VCI/VPI for side B.(Side B) tx —The transmit VCI/VPI for
side B.
(Side B) Desc—The user-entered description of the circuit.
Viewing DSX-1 and E1 CBR Module Statistics
You can view the following types of statistics for the DSX-1/E1 CBR modules:
n
DSX-1/E1 CBR Performance Monitoring (physical monitoring of the line)
n
ATM Statistics (monitoring of the ATM payload)
DSX-1/E1 CBR Performance Monitoring The DSX-1 CBR and E1 CBR
Performance Monitoring screens display the following statistics:
ES—The number of errored seconds (ESs) encountered by the DSX-1/E1 CBR
interface.
SES—The number of severely-errored seconds (SESs) encountered by the
DSX-1/E1 CBR interface.
SEFS—The number of severely errored framing seconds (SEFSs) encountered by
the DSX-1/E1 CBR interface.
UAS—The number of unavailable seconds (UASs) encountered by the DSX-1/E1
CBR interface.
CSS—The number of controlled slip seconds (CSSs) encountered by the DSX-1/E1
CBR interface.
PCV—The number of path coding violations (PCVs) encountered by the DSX-1/E1
CBR interface.
LES—The number of line errored seconds (LESs) encountered by the DSX-1/E1
CBR interface.
BES—The number of bursty errored seconds (BESs) encountered by the DSX-1/E1
CBR interface.
DM—The number of degraded minutes (DMs) encountered by the DSX-1/E1 CBR
interface.
LCV—The number of line coding violations (LCVs) encountered by the DSX-1/E1
CBR interface.
238
CHAPTER 6: PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING
DSX-1/E1 CBR ATM Statistics ATM cell statistics are cell counts since the last
counter reset. On the ATM Statistics window, you can reset the counter by
entering [c]. ATM statistics are displayed as a list rather than a table, as shown
earlier in Figure 174. The DSX-1 and E1 CBR ATM Statistics screens display the
following statistics:
Total Cells Received—Number of cells received and played out (reassembled).
Total Cells Transmitted—Number of cells sent to the cell bus.
Total Cell Pointer Errors—Number of cells dropped due to structure pointer
mismatches.
Total Cells Lost—The difference between the number of cells transmitted and the
number of cells received.
Total Number of Buffer UnderFlows—Number of underrun events.
Total Number of Buffer OverFlows—Number of overrun events.
Total out of Sequence Errors—Number of cells received with out-of-sequence
number mismatch.
Total CRC Errors—Number of cells received with uncorrectable sequence number
CRC error.
Total OAM Cells Received—Number of OAM (Operations, Administration, and
Maintenance) cells received. These cells carry OAM information used for network
management.
Total OAM Cells Transmitted—Number of OAM (Operations, Administration,
and Maintenance) cells transmitted. These cells carry OAM information used for
network management.
Current Cell Status—Cell loss period count (for CBR use only).
Viewing QSIM/HSIM/FAM Statistics
You can view the following types of statistics for the QSIM/HSIM/FAM modules:
n
HDLC Statistics
n
Frame Relay Statistics (per DLCI)
n
ATM VC Statistics (per VCI)
n
LMI Statistics
n
FAM DS1 Performance Monitoring (FAM module only)
HDLC Statistics The HDLC Statistics screen lists the following statistics:
Received Frames—The total number of received frames with good FCS at this
port.
Transmitted Frames—The total number of successfully-transmitted frames at
this port.
Discarded Invalid Frames—The total number of frames discarded at this port
because they were invalid. Invalid frames are frames that are received with good
FCS but that cannot be processed due to wrong content.
Discarded Congested Frames—The total number of frames discarded at this
port because they were congested. Congested frames are frames that were not
transmitted due to link congestion.
Viewing Statistics
239
Received bytes—The total number of bytes received at this port.
Transmitted bytes—The total number of bytes transmitted at this port.
FCS Errors—The total number of received frames with bad FCS at this port.
Frame Relay Statistics (per DLCI) When you select Frame Relay Statistics from
the QSIM, HSIM, or FAM Performance Management menu, a Frame Relay
Statistics table appears, listing configured virtual circuits. Enter a number
corresponding to one of the listed virtual circuits to display a list of Frame Relay
Statistics for that virtual circuit.
The Frame Relay Statistics screen lists the following statistics (per DLCI):
Received Frames—The total number of received frames with good FCS at this
port.
Transmitted Frames—The total number of successfully-transmitted frames at
this port.
Discarded Invalid Frames—The total number of frames discarded at this port
because they were invalid. Invalid frames are frames that are received with good
FCS but that cannot be processed due to wrong content.
Discarded Congested Frames—The total number of frames discarded at this
port because they were congested. Congested frames are frames that were not
transmitted due to link congestion.
Received bytes—The total number of bytes received at this port.
Received DE—The number of DE (Discard Eligibility) frames received at this port.
Received FECN—The number of FECN (Forward Explicit Congestion Notification)
frames received at this port.
Received BECN—The number of BECN (Backward Explicit Congestion
Notification) frames received at this port.
ATM VC Statistics (per VCI) When you select ATM VC Statistics from the QSIM,
HSIM, or FAM Performance Management menu, an ATM VC Statistics table
appears, listing configured virtual circuits. Enter a number corresponding to one of
the listed virtual circuits to display a list of ATM VC Statistics for that virtual circuit,
The ATM VC Statistics screen lists the following statistics (per VCI):
Port transmit VPI—The transmit VPI for the port side (the side toward the
connector, rather than toward the bus) of the circuit.
Port transmit VCI—The transmit VCI for the port side of the circuit.
Port receive VPI—The receive VPI for the port side of the circuit.
Port receive VCI—The receive VCI for the port side of the circuit.
Received Frames—The total number of received frames with good FCS at this
port.
Transmitted Frames—The total number of successfully-transmitted frames at
this port.
AAL5 Errors—ATM Adaptation Layer 5 (AAL5) Error counter.
Discarded Congested Frames—The total number of congested frames
discarded at this port. Congested frames are frames that were not transmitted due
to link congestion.
240
CHAPTER 6: PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING
LMI Statistics The LMI Statistics screen lists the following statistics:
Received LMI Frames—Total number of frames received at this port.
Discarded LMI Frames—Total number of frames discarded at this port.
LIV/Full Status Timeouts—Number of Link Integrity Verification (LIV) timeouts
for the User Side.
Transmit LIV Requests—Number of Link Integrity Verification (LIV) Requests
transmitted for the User Side.
Receive LIV Responses—Number of Link Integrity Verification (LIV) Responses
received for the User Side.
Transmit Full Status Requests—Number of Full Status Requests transmitted for
the User Side.
Receive Full Status Responses—Number of Full Status Responses received for
the User Side.
Loss of Seq Num Sync—Number of Sequence Number Synchronized Losses for
the User Side. The number of alarm events generated when the sequence
numbers between polling and polled units are not matched.
Receive Unconfigured PVCs—Number of unconfigured PVCs received for the
User Side.
Last statistics reset date—The date on which LMI statistics were last reset.
Last statistics reset time—The time at which LMI statistics were last reset.
FAM Performance Monitoring For the FAM module only, you can view DS1
performance monitoring statistics. The FAM Performance Monitoring screen
displays the following statistics:
ES—The number of errored seconds (ESs) encountered by the FAM interface.
SES—The number of severely-errored seconds (SESs) encountered by the FAM
interface.
SEFS—The number of severely errored framing seconds (SEFSs) encountered by
the FAM interface.
UAS—The number of unavailable seconds (UASs) encountered by the FAM
interface.
CSS—The number of controlled slip seconds (CSSs) encountered by the FAM
interface.
PCV—The number of path coding violations (PCVs) encountered by the FAM
interface.
LES—The number of line errored seconds (LESs) encountered by the FAM
interface.
BES—The number of bursty errored seconds (BESs) encountered by the FAM
interface.
DM—The number of degraded minutes (DMs) encountered by the FAM interface.
LCV—The number of line coding violations (LCVs) encountered by the FAM
interface.
Viewing Statistics
Viewing Virtual Circuit
Statistics
241
The virtual circuit statistics available for the PathBuilder S700 provide you with
circuit parameters and cell counts broken down in two ways:
n
by circuit
n
by port/group
These statistics enable you to look at cell loss at various points in the data flow and
adjust parameters—such as shaper values—accordingly.
Viewing Virtual Circuit Statistics by Circuit
To display virtual circuit statistics by circuit, follow these steps:
1 From the Configuration Management menu, select [2] Manage Circuits to display
the Virtual Circuit menu.
2 From the Virtual Circuit menu select [5] Show Virtual Circuit Statistics to display a
summary of statistics for all circuits, as shown in Figure 178.
Figure 178 Show Virtual Circuit Statistics Window
Each pair of rows on the Virtual Circuit Statistics Summary screen provides the
following information about one of the existing virtual circuits:
Row 1 (left to right)
VC#—Virtual circuit ID number.
Card—Side A card type.
s/p: vi—(Side A) slot number /port number: virtual interface number.
rx—(Side A) receive VCI/VPI (IP address for the MCPU card).
tx—(Side A) transmit VCI/VPI (IP address for the MCPU card).
Card—Side B card type.
s/p: vi—Side B slot number /port number: virtual interface number.
rx—Side B receive VCI/VPI (IP address for the MCPU card).
tx—Side B transmit VCI/VPI (IP address for the MCPU card).
Description—Virtual circuit description.
242
CHAPTER 6: PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING
Row 2 (left to right)
rcvd from—number of cells received on side A per port or group
dropped—number of cells dropped on side A due to queue congestion or early
packet discard (EPD).
rcvd from—number of cells received on side B per port or group
dropped—number of cells dropped on side B due to queue congestion or early
packet discard (EPD).
3 To view additional information about a particular circuit, enter the desired virtual
circuit number to display the Virtual Circuit Statistics Detail screen for that circuit.
Figure 179 shows a representative Virtual Circuit Statistics Detail screen.
Figure 179 Show Virtual Circuits Detail Window
The Virtual Circuit Statistics Detail screen displays the following statistics:
For further details about conforming CLPO+CLP1 and non-conforming CLP1+CLP0
cells, see “Conforming/Non-Conforming Cell Counters” later in this section.
Received—Total number of cells received (conforming CLPO+CLP1 and
non-conforming CLP1+CLPO cells).
Conf CLP0—Ingress CLPO; the number of conforming CLP=0 cells received.
ConfCLP1—Ingress CLP1; the number of conforming CLP=1 cells received.
Nonconf CLP0—Number of non-conforming CLP=0 cells received. This
counter is used only with Policing enabled.
NonconfCLP1—Number of non-conforming CLP=1 cells received. This counter
is used only with Policing enabled.
Dropped (due to congestion)—Number of cells dropped due to queue
congestion or EPD (early packet discard).
Sent—Total number of cells sent (total of CLP0 + CLP1 cells).
CLP0—Total number of CLP=0 cells sent.
CLP1—Total number of CLP=1 cells sent.
Last Cleared—Date and time that the statistics were last cleared.
Viewing Statistics
243
Conforming/Non-Conforming Cell Counters
The conforming and non-conforming cells reflect a cell’s ingress types (CLP0 or
CLP1) prior to any policing actions. These counters do not count a cell more than
once. If a cell is received as a CLP0 type and is then tagged due to policing, the cell
will still be counted as a CLP0 cell.
The following subsections provide additional information that applies to the
conforming and non-conforming cell counters, depending on which policing
configuration you choose.
Conforming/Non-Conforming Cell Counters for CBR Traffic
Config 1
Conf CLP0 = Conforming CLP0 cells
Conf CLP1 = Ingress CLP1 cells
Nonconf CLP0 = Non-conforming CLP0 cells that were tagged
Nonconf CLP1 = not counted
Config 2
Conf CLP0 = Conforming CLP0 cells
Conf CLP1 = Conforming CLP1 cells
Nonconf CLP0 = Non-conforming CLP0 cells that were dropped
Nonconf CLP1 = Non-conforming CLP1 cells that were dropped
Total dropped cell count = Received - Sent
Conforming/Non-Conforming Cell Counters for Non-CBR Traffic
Config 1
Conf CLP0 = Conforming CLP0 cells
Conf CLP1 = Conforming CLP1 cells
Nonconf CLP0 = Non-conforming CLP0 cells that were tagged and/or dropped
Nonconf CLP1 = Non-conforming CLP1 cells that were dropped
Tagged cell count = Sent CLP1 - Conf CLP1
Total dropped cell count = Received - Sent
Total dropped by policing = ((Received - Sent) - Dropped (due to congestion))
Config 2
Conf CLP0 = Conforming CLP0 cells
Conf CLP1 = Conforming CLP1 cells
Nonconf CLP0 = Non-conforming CLP0 cells that were tagged
Nonconf CLP1 = Non-conforming CLP1 cells that were dropped
Tagged cell count = Sent CLP1 - Conf CLP1
Total dropped cell count = Received - Sent
Total dropped by policing = ((Received - Sent) - Dropped (due to congestion))
244
CHAPTER 6: PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING
Viewing Virtual Circuit Statistics by Port/Group
To display statistics for all virtual circuits by port/group, follow these steps:
1 From the Configuration Management menu, select [2] Manage Circuits to display
the Virtual Circuit menu.
2 From the Virtual Circuit menu select [6] Show Virtual Circuit Statistics By
Port/Group to view a summary of statistics for all circuits on each port/group. The
Virtual Statistics by Port/Group Summary screen, shown in Figure 180, displays the
following information for each port/group:
Port/Group—The port and group number.
rcvd from—The number of cells received.
(rcvd from) dropped—The number of received cells dropped.
rcvd for—The number of cells sent.
(rcvd for) dropped—The number of sent cells dropped.
Figure 180 Virtual Statistics by Port/Group Summary Screen
3 To view the number of cells received, dropped, and sent from and to a particular
port/group, enter the desired pot/group number to display the Virtual Circuit
Statistics by Port/Group Detail screen, shown in Figure 181.
Viewing Statistics
Figure 181 Virtual Circuit Statistics By Port/Group Detail Window
From the Virtual Circuits by Port/Group detail screen, you can:
n
Press [c] to clear all statistics.
n
Press [v] to show VCs.
n
Press [q] to view summary statistics by queue.
n
Press [i] to view summary statistics by virtual interface.
245
246
CHAPTER 6: PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING
TECHNICAL SUPPORT
A
3Com provides easy access to technical support information through a variety of
services. This appendix describes these services.
Information contained in this appendix is correct at time of publication. For the
very latest, 3Com recommends that you access the 3Com Corporation
World Wide Web site.
Online Technical
Services
World Wide Web Site
3Com offers worldwide product support 24 hours a day, 7 days a week, through
the following online systems:
n
World Wide Web site
n
3Com FTP site
n
3Com Bulletin Board Service (3Com BBS)
n
3ComFacts automated fax service
SM
Access the latest networking information on the 3Com Corporation World Wide Web
site by entering the URL into your Internet browser:
http://www.3com.com/
This service provides access to online support information such as technical
documentation and software library, as well as support options ranging from
technical education to maintenance and professional services.
3Com FTP Site
Download drivers, patches, and software, across the Internet from the 3Com public
FTP site. This service is available 24 hours a day, 7 days a week.
To connect to the 3Com FTP site, enter the following information into your FTP
client:
n
Hostname: ftp.3com.com (or 192.156.136.12)
n
Username: anonymous
n
Password: <your Internet e-mail address>
A user name and password are not needed with Web browser software such as
Netscape Navigator and Internet Explorer.
248
APPENDIX A: TECHNICAL SUPPORT
3Com Bulletin Board
Service
The 3Com BBS contains patches, software, and drivers for 3Com products. This
service is available through analog modem or digital modem (ISDN) 24 hours a
day, 7 days a week.
Access by Analog Modem
To reach the service by modem, set your modem to 8 data bits, no parity, and
1 stop bit. Call the telephone number nearest you:
Country
Data Rate
Telephone Number
Country
Data Rate
Telephone Number
Australia
Up to 14,400 bps
61 2 9955 2073
Japan
Up to 14,400 bps
81 3 3345 7266
Brazil
Up to 14,400 bps
55 11 5181 9666
Mexico
Up to 28,800 bps
52 5 520 7835
France
Up to 14,400 bps
33 1 6986 6954
P.R. of China
Up to 14,400 bps
86 10 684 92351
Germany
Up to 28,800 bps
4989 62732 188
Taiwan, R.O.C.
Up to 14,400 bps
886 2 377 5840
Hong Kong
Up to 14,400 bps
852 2537 5601
U.K.
Up to 28,800 bps
44 1442 438278
Italy
Up to 14,400 bps
39 2 27300680
U.S.A.
Up to 28,800 bps
1 408 980 8204
Access by Digital Modem
ISDN users can dial in to the 3Com BBS using a digital modem for fast access up to
56 Kbps. To access the 3Com BBS using ISDN, use the following number:
1 408 654 2703
3ComFacts Automated
Fax Service
The 3ComFacts automated fax service provides technical articles, diagrams, and
troubleshooting instructions on 3Com products 24 hours a day, 7 days a week.
Call 3ComFacts using your Touch-Tone telephone:
1 408 727 7021
Support from Your
Network Supplier
If additional assistance is required, contact your network supplier. Many suppliers
are authorized 3Com service partners who are qualified to provide a variety of
services, including network planning, installation, hardware maintenance,
application training, and support services.
When you contact your network supplier for assistance, have the following
information ready:
n
Product model name, part number, and serial number
n
A list of system hardware and software, including revision levels
n
Diagnostic error messages
n
Details about recent configuration changes, if applicable
If you are unable to contact your network supplier, see the following section on
how to contact 3Com.
Support from 3Com
Support from 3Com
249
If you are unable to obtain assistance from the 3Com online technical resources or
from your network supplier, 3Com offers technical telephone support services. To
find out more about your support options, please call the 3Com technical
telephone support phone number at the location nearest you.
When you contact 3Com for assistance, have the following information ready:
n
Product model name, part number, and serial number
n
A list of system hardware and software, including revision levels
n
Diagnostic error messages
n
Details about recent configuration changes, if applicable
Below is a list of worldwide technical telephone support numbers:
Country
Telephone Number
Country
Telephone Number
Asia Pacific Rim
Australia
Hong Kong
India
Indonesia
Japan
Malaysia
New Zealand
Pakistan
Philippines
1 800 678 515
800 933 486
61 2 9937 5085
001 800 61 009
0031 61 6439
1800 801 777
0800 446 398
61 2 9937 5085
1235 61 266 2602
P.R. of China
10800 61 00137 or
021 6350 1590
800 6161 463
Europe
From anywhere in Europe, call:
Singapore
S. Korea
From anywhere in S. Korea:
From Seoul:
Taiwan, R.O.C.
Thailand
82 2 3455 6455
00798 611 2230
0080 611 261
001 800 611 2000
+31 (0)30 6029900 phone
+31 (0)30 6029999 fax
From the following European countries, you may use the toll-free numbers:
Austria
Belgium
Denmark
Finland
France
Germany
Hungary
Ireland
Israel
Italy
06 607468
0800 71429
800 17309
0800 113153
0800 917959
0130 821502
00800 12813
1 800 553117
177 3103794
1678 79489
Netherlands
Norway
Poland
Portugal
South Africa
Spain
Sweden
Switzerland
U.K.
0800 0227788
800 11376
0800 3111206
05 05313416
0800 995014
900 983125
020 795482
0800 55 3072
0800 966197
Latin America
Argentina
Brazil
541 312 3266
55 11 523 2725, ext. 422
Colombia
Mexico
571 629 4847
01 800 849 2273
North America
1 800 NET 3Com
(1 800 638 3266)
250
APPENDIX A: TECHNICAL SUPPORT
Returning Products
for Repair
Before you send a product directly to 3Com for repair, you must first obtain a
Return Materials Authorization (RMA) number. Products sent to 3Com without
RMA numbers will be returned to the sender unopened, at the sender’s expense.
To obtain an RMA number, call or fax:
Country
Telephone Number
Fax Number
Asia, Pacific Rim
65 543 6342
65 543 6348
Europe, South Africa, and
Middle East
011 44 1442 435860
011 44 1442 435718
From the following European countries, you may call the toll-free numbers; select option 2 and
then option 2:
Austria
Belgium
Denmark
Finland
France
Germany
Hungary
Ireland
Israel
Italy
Netherlands
Norway
Poland
Portugal
South Africa
Spain
Sweden
Switzerland
U.K.
06 607468
0800 71429
800 17309
0800 113153
0800 917959
0130 821502
00800 12813
1800553117
177 3103794
1678 79489
0800 0227788
800 11376
00800 3111206
05 05313416
0800 995014
900 983125
020 795482
0800 55 3072
0800 966197
Latin America
1 408 326 2927
1 408 764 6883
U.S.A. and Canada
1 800 876 3266, option 2
1 408 764 7120
251
INDEX
Symbols
(DFA) VCI 199
(DFA) VCI Range 199
(DFA) VPI 198
Numbers
3Com bulletin board service (3Com
BBS) 248
3Com URL 247
3ComFacts 248
A
AAL1 structured DS1 94
AAL5 Errors 239
AAL5 pad and trailer 87
AC power input 19
AC power requirements 17
AC/DC power connections 17, 18
AC/DC source specifications 17
access status 59
activation min. 137
activation rate 137, 138
Actual Card Type 120
Add Source Address Filter screen 157
Add Virtual Circuit screen 183
initial 184
Add Virtual Interface Configuration
menu 124
Admin Status 120, 129, 131, 133, 137,
175
administrative status. See Admin Status
AFA 137
Age 160
Aging Timer 154
alarm connectors 49
alarm indicator 60, 61
within the NMS 60, 61
alarms
acknowledging 61
audible 48
causing clock source failure 110
clearing 206
clearing history 220
common 211
connecting audible 50
connecting external 49
connecting office 48, 49
connecting visual 50
DS1/E1 UNI module 213
DSX-1/E1 CBR module 218
external 48
FAM 219
history 219
managing 205
QSIM 219
setting external 121
system (MCPU/STX) 207
viewing and clearing current 205
viewing and printing history 219
visual 48
application modules 7
configuring 119
setting the status of 120
applications
CBR 90
Ethernet and voice 95
Frame 99
integrated PathBuilder S700 91
overview 85
architecture 6
ATM Cell Mapping 132, 133
ATM modules
See DS3 UNI module, E3 UNI
module, OC3/STM-1 UNI module,
DS1/E1 UNI module.
ATM Payload Scramble 129, 132, 133
ATM router 165
ATM statistics
E3 UNI module 230
OC3/STM-1 UNI module 232
overview 226
ATM VC statistics 237, 239
audible alarm 48
audible alarm connector pinouts 50
Audience 1
auto logout 60
autolog timeout, setting 60
Automatic Frequency Adjustment . See
AFA.
B
baud rate 111
bit error rate 137
translated into total number of
errors 138
BITS clock
connecting 51
Bridge 153
Bridge Configuration menu 154
Bridge menu 154
Bridge Setup menu 156
Bridge Static Table 160
Bridge Static Table menu 160
bridging 85, 97, 98
addressing 86
configuring 119, 153
filtering 86, 155, 156, 158
filtering. See also specific types of
filtering.
learning bridge 86
List Forwarding Table 159
reassembly 88
segmentation 87
Spanning Tree 88
static table 160
statistics 235
Broadcast Frames 235
bulletin board service 248
C
card statistics
how to view 227
Card Statistics menu 227
card, resetting 120
CARD-TYPE 116
CBR
application 90
modes of operation 90
CBR Configuration menu 167
CBR DSX/E1 Card Configuration
menu 167
CBR DSX/E1 Port Configuration
menu 168
CBR module See DSX-1/E1 CBR module
CE notice xii
Cell Loss Integration Period 193
channel associated signaling (CAS) 92
multiframe structure for 3x64kbit/s
DS1 or E1 92
class of service 10
clearance xii
minimum xi
clock mode, setting 109
clock source failure, alarms that
cause 110
clock sources, designating 107, 108
CLP to DE mapping 197
code image 117
backing up 117
backing up and restoring 116
restoring 118
communication parameters 62
default 110
community name, configuring for Ethernet
port 65
conditions of acceptability ix
configuration 105
application modules 119
bridging 119
DS1/E1 UNI module 134
DSX-1/E1 CBR module 166
E3 UNI module 133
Ethernet module 151
general system information 105, 106
IP over ATM 119
MCPU module 105, 122
OC3/STM-1 UNI module 128
options 63
overview 118
QSIM/HSIM/FAM 172
QSIM/HSIM/FAM card 180
QSIM/HSIM/FAM Local Management
Interface (LMI) 178
QSIM/HSIM/FAM ports 172
shelf 120
STX module 127
system clock 107
typical 96
virtual circuits 119
virtual interfaces 122
VT100 terminal 57
Configuration Management Main menu
option 59
Configuration Management menu 119
configured card type 120
Congested Frames 238, 239
connections
BITS clock 51
DS1/E1 UNI module 27
DS3 UNI module 23, 24
DSX-1/E1 CBR module 30, 31
Ethernet module 28, 29
FAM 46
HSIM 44
252
INDEX
I/O cabling and wiring 22
management terminal 55
OC3/STM-1 UNI module 26
office alarm 47, 48
QSIM 33
rear redundant modules 53
conventions
notice icons 2
text 2
CRC-4 171
creepage xii
minimum xi
D
data bits 111
Data Rate 175
database 116, 117
backing up 116
backing up and restoring 116
erasing 72
restoring 117
DBA. See dynamic bandwidth allocation
DC power connections 20
DE to CLP mapping 195
deactivation min. 137
deactivation rate 137
Default 68
default gateway
configuring 62, 68
Default Gateway Configuration menu 68
Designated Bridge ID 236
Destination Address Filter menu 158
destination address filtering 158
diagnostics 205
Discarded Frames 235, 240
Disp. (Disposition) 159
Display Current Alarm screen 206
Display History Alarm screen 219, 220
downloading firmware
via Ethernet port 113
via FTP 114
via serial port 113
drop and insert, midspan 90
DS0 channels 194
DS0 combining, structured 91
DS1 80
DS1 Frame Access module
See also FAM.
DS1 tunneling 93, 94
DS1 UNI Configuration menu 136
DS1/E1 UNI Configuration menu 135
DS1/E1 UNI module 7
alarms 213
configuring 134
connecting 27
group ATM statistics 234
group performance statistics 234
LEDs 27, 28
overview 80
port/link IMA link ATM statistics 234
port/link IMA link performance
statistics 233
port/link performance statistics 233
specifications 10
DS1/E1 UNI Port Configuration
menu 136
DS1/E1 UNI ports, configuring 135
DS3 Framing Mode 131
DS3 timing source 132
DS3 UNI Configuration menu 130
DS3 UNI Interval Performance Monitoring
screen 226
DS3 UNI Loopback menu 221
DS3 UNI module 7
ATM statistics 226, 229
connecting 23, 24
LEDs 25
loopback options 222
loopbacks 222
operation 80
overview 80
performance monitoring 228
performance statistics 229
statistics 229
DSX 32, 82
DSX-1/E1 CBR module 7
alarms 218
ATM statistics 238
configuring 166
connecting 30, 31
connector pinouts 30
LBOs 31
LEDs 32
loopback options 224
loopbacks 224
overview 82
performance monitoring 237
performance statistics 237
pinouts 30
standards support 83
timing options 171
viewing statistics 237
virtual circuit configuration
parameters 193
DXI application 100
DXI Format Mode 1A 101
DXI Mode 1A 99, 100, 101
DXI router to ATM connection 100
dynamic bandwidth allocation 92, 166
E
E1 83, 84
E1 CBR module
input power requirements xi
E3 timing source 134
E3 UNI Configuration menu 133
E3 UNI module 7
ATM statistics 230
configuring 133
input power requirements xi
loopback options 223
loopbacks 222
overview 80
performance monitoring 229
performance statistics 229
statistics 230
early packet discard (EPD) 199
EMI x
Encapsulation Mode 195
End Frame Relay DLCI 195
End FR-SSCS DLCI 198
equipment list 115
viewing 115
Ethernet and voice application 95
Ethernet Card Configuration menu 152
Ethernet Configuration menu 151
Ethernet management port,
configuring 63
Ethernet module 7
configuring 151
connecting 28, 29
connectingconnections
Ethernet module 28
connector pinouts 28
data flow 81
functional block diagram 82
LEDs 30
operation 81
overview 81
performance monitoring 235
pinouts 28
standards support 81
viewing statistics 235
virtual circuit configuration
parameters 193
Ethernet Port #1 Configuration
menu 151, 152
Ethernet Port IP Configuration menu 64
Exit 59
Exit Main menu option 59
external alarm 48
external alarm connector pinouts 49
F
FAM 7
alarms 219
connecting 46
loopback options 225
loopbacks 224
performance at small frame
sizes 178
performance monitoring 240
FAM Configuration menu 178
FAM. See also Frame Relay modules.
Fault Management Main menu
option 59
Fault Management menu 205, 206
fax service (3ComFacts) 248
FCC Part 68 Statement xi
FCS Errors 239
FCS Size 175
FEAC Loopback 132
FECN to EFCI Mapping 198
fiber optic cable
multi-mode 26
single mode 26
filters, enabling 156
firmware
downloading via Ethernet port 113
downloading via FTP 114
downloading via serial port 113
firmware, viewing version number 111
Flooded Frames 235
Forward Delay 236
Forwarded Frames 235
Frame Access module. See FAM.
Frame application 99
Frame Relay 99
interworking functions 102
See also Service Interworking,
Network Interworking.
statistics 239
virtual circuit configuration
parameters 195
253
IP over ATM LAN Router Configuration
menu 164
IP over ATM menu 162
LBO 9, 136, 169, 174
LBO Length 131
LED startup sequence 23
LEDs
ACO MCPU 47
Active (ACTV) 23
ATM (GREEN) Ethernet 29
CLK QSIM 43
Critical MCPU 47
DS1/E1 UNI module 27, 28
DS3 UNI module 25
DSX-1/E1 CBR module 32
ENBL QSIM 43
Ethernet module 30
Fail 23
FWD (GREEN) Ethernet 29
In Service (INS) 23
Inservice FAM 47
Inservice HSIM 45
Link Port 2 (GREEN) Ethernet 29
Link Port1 (GREEN) Ethernet 29
LOCD (RED) DS3 24
LOF (RED) DS3 24
LOS (RED) DS3 24
Major MCPU 47
MCPU module 47, 48
Minor MCPU 47
Not Used FAM 47
Not Used HSIM 45
OC3/STM-1 UNI module 26
Power (PWR) 23
QSIM 43
RX Port 1 (GREEN) Ethernet 29
RX Port2 (GREEN) Ethernet 29
STX module 51
Test 23
TX Port 1 (GREEN) Ethernet 29
TX Port 2 (GREEN) Ethernet 29
legacy module support 5
Line Code 136, 169, 174
line coding 10
line framing 10
Link Type 174
List Card menu 119
List Forwarding Table 159
List Virtual Circuit Detail screen 200, 201
List/Modify Virtual Interface menu 125
LIV/Full Status Timeouts 240
LMI statistics 240
Local 65
local card loopback 222, 223, 224, 225
local host IP address
configuring 62, 63
Local Host IP Configuration menu 64
Local Management Interface 178
logging on 57
Loopback menu 220, 221
loopbacks 220
DSX-1/E1 CBR module 224
local card 222, 223, 224, 225
network card 222, 224, 225
network line 222, 223, 224, 225
LOS 24
Loss of Seq Num Sync 240
L
M
LAN connectivity 98
LAN router 164
MAC Address 159, 161
MAC MTU Exceeded 235
Frame Relay modules
overview 84
Framing 9, 137, 170, 174
FRF.8 transparent encapsulation
mode 196
full system configuration 22
G
Gain Limit 137
General System Information menu 71,
106
general system information,
configuring 106
getting started 57
Group 138
H
HDLC statistics 238
HDLC/SDLC 99, 103, 104
virtual circuit configuration
parameters 199
Hello Time 236
HSII Serial Interface module. See HSIM.
HSIM 7
connecting 44
performance at small frame
sizes 177
HSIM. See also Frame Relay modules.
I
Inband Lpbk 137
in-band management, configuring 68
initial configuration information,
entering 57
initial configuration, performing 61
installation 15
general procedure 16
of additional modules 21
overview 15
interface card, resetting 115
interfaces 9
IP address 165
setting default gateway 68
setting Ethernet port 64
setting SLIP management port 66
setting trap client 67
IP host setup 65
IP over ATM
configuring 119, 161
IP over ATM Admin. Status Change
menu 165
for Bridging Control status 165
for IP over ATM 165
IP over ATM ATM Router Configuration
menu 165
IP over ATM Configuration screen 162,
163
Main menu 59
Manage Bridge Configuration menu
option 118
Manage Bridge menu 153
Manage Card Configuration menu
option 118
Manage Circuit Configuration menu
option 118
Manage IP Network Configuration
menu 62
Manage IP over ATM Configuration menu
option 118
management terminal
connecting 55
connection options 55, 57
management terminal. See also NMS.
Max. Frame Size 181
Maximum Age 236
maximum burst size (MBS) 126
MCPU module
configuring 105, 122
LEDs 47, 48
overview 77
viewing configuration
information 122
menus
changing settings 60
hierarchy 60
how to use 59
navigating 59
Min. Flag Bytes 175
multicast leaf circuits
configuring 190
definition 184
multicast source circuits
configuring 189
definition 184
N
network card loopback 222, 224, 225
network interworking 102, 103
network line loopback 222, 223, 224,
225
Network PV Timer (T392) 179
network supplier support 248
non-revertive (clock mode) 109
notice icons 2
O
OC3 228
OC3 /STM-1 UNI Performance
Management menu 228
OC3/STM-1 UNI Configuration
menu 128
OC3/STM-1 UNI module 7
ATM statistics 232
configuring 128
connecting 26
LEDs 26
loopback options 223
loopbacks 223
overview 80
performance monitoring 230
performance statistics 230
viewing statistics 230
office alarm connector
connecting 47, 48
254
INDEX
Onhook Detection 193
online technical services 247
operational status 120
options and parts list 12
P
parameters, changing settings 60
parity 111
Part # 116
part #-idprom 116
part numbers and descriptions 12
part#-oem 116
passwords
changing default 71
entering 58
setting default 71
PathBuilder S700 Release Notes 3
PathBuilder Switch Manager User
Guide 3
peak cell rate (PCR) 126
Peak Rate 130, 132, 133
Performance Management Main menu
option 59
Performance Management menu 227
performance monitoring 205
DS3 UNI module 229
E3 UNI module 229
Ethernet module 235
OC3/STM-1 UNI module 230
QSIM/HSIM/FAM 238
performance statistics
current 225
interval 226
overview 225
total 226
pinouts
audible alarm 50
DSX-1/E1 CBR module 30
EIA530 DCE cable 39
EIA530 DTE cable 38
Ethernet module 28
external alarm 49
HSSI straight DTE to DCE cable 40
RS-422/449 DCE cable 37
RS-422/449 DTE cable 36
STX BITS clock input connector 52
STX BITS clock output connector 52
Telco (T1/E1) rear connector 54
V.35 DCE cable 35
V.35 DTE cable 34
visual alarm 50
X.21 DCE cable 42
X.21 DTE cable 41
PLCP Timing Source 132
Port Mode 169
Port Number (trap client) 67
ports
designating as clock source 108
power and power cords ix
power connections 17, 18
DC 20
power input
AC 19
DC 20
power requirements 17
power supplies
setting status of 121
power supply requirements 18
Procedure 179
Protocol 179
PVC mapping 99
RS-232 ports 110
default settings 110
S
Q
QSIM 7, 195
alarms 219
cabling options 33
connecting 33
connector pinouts 34, 35, 36, 37,
38, 39, 41, 42
LEDs 43
performance at small frame
sizes 176
QSIM Card Configuration menu 180
QSIM Configuration menu 172, 173
QSIM LMI Configuration menu 178, 179
QSIM Port Configuration menu 173, 174
QSIM Port Configuration Selection
menu 173
QSIM. See also Frame Relay modules.
QSIM/HSIM/FAM
configuring 172
configuring card 180
configuring ports 172
performance at small frame
sizes 176
performance monitoring 238
statistics 238
QSIM/HSIM/FAM Local Management
Interface (LMI), configuring 178
Quad Serial Interface module. See QSIM.
R
rack mounting ix, 8, 17
Read Only 59
read-only password 71
Read-Write 59
read-write password 71
read-write session, taking over 72
rear cable access 5
rear redundant modules 5, 7
connecting 53
connector pinouts 54
Receive Timing Phase 175
Received BECN 239
Received FECN 239
Received Frames 236, 239, 240
Received Full Status Resp 240
Received LIV Resp 240
receiving and inspecting 15
Regulatory Information xi
Report Firmware Version screen 111,
112
resetting a card 120
resetting system 72
resetting the interface card 115
returning products for repair 250
rev # 116
revertive (clock mode) 109
Root Bridge 236
Root Path Cost 236
RS 110
RS-232 parameters, viewing and
configuring 110
RS-232 Port #2 Configuration
menu 110, 111
Safety Classification of Ports x
SAP Filtered 235
serial # 116
service interworking 102
Servicing ix
Shaper 193
Shaper Number 198, 199
shapers
configuring VI (bulk) 124
Shelf 120
shelf
configuring 120
Shelf Configuration menu 121
Show 115
Signaling Type 194
site requirements 16
SLIP/PPP 63
slot # 115
slot assignments 7
SNMP 63, 78
SNMP MIB standards support 78
SNMP support 9
Sonet Interface Mode 129
Source Address Filter menu 157
source address filtering 156
Source Protocol Filter menu 155
source protocol filtering 155
Spanning Tree 88
enabling and disabling 161
instances 89
operation 89
statistics 236
VC-VC bridging operation 89
specifications 16
Specify Virtual Circuit menu 163
standards compliance 9
standards support
SNMP MIB 78
standby code 113, 114
Start Frame Relay DLCI 195
Start FR-SSCS DLCI 198
startup sequence (LED) 23
statistics 9
ATM VC 237, 239
bridging and Ethernet 235
DS1/E1 UNI module group ATM 234
DS1/E1 UNI module group
performance 234
DS1/E1 UNI module port/link IMA link
ATM 234
DS1/E1 UNI module port/link IMA link
performance 233
DS1/E1 UNI module port/link
performance 233
DS3 UNI module ATM 229
DSX-1/E1 CBR module ATM 238
DSX-1/E1 CBR module
performance 237
Ethernet module 235
Frame Relay 239
HDLC 238
how to view card 227
LMI 240
OC3/STM-1 UNI 230
255
overview 225
overview of ATM 226
overview of card 225
overview of card performance 225
overview of virtual circuit 227
QSIM/HSIM/FAM 238
See also ATM statistics, performance
monitoring, other specific types of
statistics.
Spanning Tree 236
viewing DS1/E1 UNI module 232
viewing DSX-1/E1 CBR module 237
viewing virtual circuit 241
stop bits 111
structured mode 90, 169
versus unstructured mode 95
versus unstructured mode (effects on
transit DS1) 95
STX module
BITS clock pinouts 52
configuring 127
LEDs 51
STX Module Configuration menu 127,
128
subnet mask 165
setting default gateway 68
setting Ethernet port 64
setting SLIP management port 66
setting trap client 67
super user functions 70
super user password 71
Super User Privilege menu 71
Supplementary Regulatory Information ix,
xi
supported modules
application 80
sustained cell rate (SCR) 126
Switch 113, 114
System Administration Main menu
option 59
System Administration menu 62, 105,
106
system clock
managing 107
setting mode 109
System Clock Configuration menu 107
system configuration, full 22
system description 5
system information
specifying 106
viewing and configuring 105
system module, overview 77
system timing, specifying clock sources
for 108
T
technical support
3Com URL 247
bulletin board service 248
fax service 248
network suppliers 248
product repair 250
Telnet 63
terminal access methods 63
Terminal Timing Source 175
Time 73
Time and Date Configuration menu 73
time and date, setting 73
Timing 137, 174
Timing Source 130
title screen 58
traffic contract 99
traffic policing 10
traffic shaping 10
Translation 196
translation encapsulation mode 196
Transmitted Frames 238, 239
Transmitted Full Status Resp 240
Transparent 195
Trap 66
Trap Client 1 Configuration menu 67
Trap Client Configuration menu 67
trap clients
configuring 62, 66
U
unicast circuits
configuring 185
definition 184
unstructured mode 90, 93, 170
URL 247
User Error Threshold (N392) / User ME
Count (N393) 180
User FS Polling Counter (N391) 179
User LIV Polling Timer (T391) 179
V
VCC 185
Verifying 51
Virtual Channel Identifier (VCI) 182
virtual circuit configuration parameters
DSX-1/E1 CBR module 193
Ethernet module 193
Frame Relay 195
HDLC/SDLC 199
Virtual Circuit menu 183
virtual circuit scheme 76
virtual circuits 10
adding 183
ATM module parameters 193
common parameters 192
configuring 119
configuring multicast leaf 190
configuring multicast source 189
configuring unicast 185
in a simple network 76
in a switched network 87
overview of statistics 227
viewing existing 199
viewing statistics 241
virtual interfaces
adding 123
configuring 122
creating 123
deleting 126
viewing and modifying 125
Virtual Interfaces Configuration
menu 123
Virtual Path Identifier (VPI) 182
visual alarm 48
visual alarm connector pinouts 50
VPC 185
VPI/VCI Ranges 182
VT100 terminal configuration 57
W
warning information ix
World Wide Web (WWW) 247
256
INDEX
3Com Corporation LIMITED WARRANTY
HARDWARE
3Com warrants its hardware products to be free from defects in workmanship and materials, under normal use and service, for
the following lengths of time from the date of purchase from 3Com or its authorized reseller:
Network Interface Cards
Lifetime
Other hardware products
*unless otherwise specified above
1 year*
Spare parts and spares kits
90 days
If a product does not operate as warranted above during the applicable warranty period, 3Com shall, at its option and expense,
repair the defective product or part, deliver to Customer an equivalent product or part to replace the defective item, or refund
to Customer the purchase price paid for the defective product. All products that are replaced will become the property of
3Com. Replacement products may be new or reconditioned. Any replaced or repaired product or part has a ninety (90) day
warranty or the remainder of the initial warranty period, whichever is longer.
SOFTWARE
3Com warrants that the software programs licensed from it will perform in substantial conformance to the program
specifications therefor for a period of ninety (90) days from the date of purchase from 3Com or its authorized reseller. 3Com
warrants the media containing software against failure during the warranty period. No updates are provided. 3Com’s sole
obligation with respect to this express warranty shall be (at 3Com’s discretion) to refund the purchase price paid by Customer
for any defective software products, or to replace any defective media with software which substantially conforms to applicable
3Com published specifications. Customer assumes responsibility for the selection of the appropriate applications program and
associated reference materials. 3Com makes no warranty or representation that its software products will meet Customer’s
requirements or work in combination with any hardware or applications software products provided by third parties, that the
operation of the software products will be uninterrupted or error free, or that all defects in the software products will be
corrected. For any third party products listed in the 3Com software product documentation or specifications as being
compatible, 3Com will make reasonable efforts to provide compatibility, except where the non-compatibility is caused by a
“bug” or defect in the third party's product.
YEAR 2000 WARRANTY
In addition to the Hardware Products Warranty and Software Products Warranty identified above, 3Com warrants that all
Heritage 3Com products sold or licensed to Customer on and after January 1, 1998 that are date sensitive will continue
performing properly with regard to such date data on and after January 1, 2000, provided that all other products used by
Customer in connection or combination with the 3Com products, including hardware, software, and firmware, accurately
exchange date data with the 3Com products, with the exception of those products identified at 3Com’s Web site,
http://www.3com.com/products/yr2000.html, as not meeting this standard. A product is considered a “Heritage 3Com product”
if it is a member of a product family which was manufactured by 3Com prior to its merger with US Robotics Corporation. This
Year 2000 limited warranty does not apply to Heritage US Robotics Corporation products. If it appears that any such product
does not perform properly with regard to such date data on and after January 1, 2000, and Customer notifies 3Com before the
later of April 1, 2000, or ninety (90) days after purchase of the product from 3Com or its authorized reseller, 3Com shall, at its
option and expense, provide a software update which would effect the proper performance of such product, repair such
product, deliver to Customer an equivalent product to replace such product, or if none of the foregoing is feasible, refund to
Customer the purchase price paid for such product.
Any software update or replaced or repaired product will carry a Year 2000 Warranty for ninety (90) days or until April 1, 2000,
whichever is later.
OBTAINING WARRANTY
SERVICE
Customer must contact 3Com’s Corporate Service Center or an Authorized 3Com Service Center within the applicable
warranty period to obtain warranty service authorization. Dated proof of purchase may be required. Products returned to
3Com’s Corporate Service Center must be pre-authorized by 3Com with a Return Material Authorization (RMA) number
marked on the outside of the package, and sent prepaid and packaged appropriately for safe shipment, and it is recommended
that they be insured. The repaired or replaced item will be shipped to Customer, at 3Com’s expense, not later than thirty (30)
days after receipt of the defective product by 3Com.
Dead- or Defective-on-Arrival. In the event a product completely fails to function or exhibits a defect in materials or
workmanship within the first forty-eight (48) hours of installation but no later than thirty (30) days after the date of purchase,
and this is verified by 3Com, it will be considered dead- or defective-on-arrival (DOA) and a replacement shall be provided by
advance replacement. The replacement product will normally be shipped not later than three (3) business days after 3Com’s
verification of the DOA product, but may be delayed due to export or import procedures. When an advance replacement is
provided and Customer fails to return the defective product to 3Com within fifteen (15) days after shipment of the
replacement, 3Com will charge Customer for the replacement product, at list price.
3Com shall not be responsible for any software, firmware, information, or memory data of Customer contained in, stored on,
or integrated with any products returned to 3Com for repair, whether under warranty or not.
WARRANTIES EXCLUSIVE
IF A 3COM PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE, CUSTOMER’S SOLE REMEDY FOR BREACH OF THAT
WARRANTY SHALL BE REPAIR, REPLACEMENT, OR REFUND OF THE PURCHASE PRICE PAID, AT 3COM’S OPTION. TO THE FULL
EXTENT ALLOWED BY LAW, THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER
WARRANTIES, TERMS, OR CONDITIONS, EXPRESS OR IMPLIED, EITHER IN FACT OR BY OPERATION OF LAW, STATUTORY OR
OTHERWISE, INCLUDING WARRANTIES, TERMS, OR CONDITIONS OF MERCHANTABILITY, FITNESS FOR A PARTICULAR
PURPOSE, AND SATISFACTORY QUALITY. 3COM NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR
IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE OR USE OF ITS PRODUCTS.
3COM SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THAT THE ALLEGED
DEFECT IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER’S OR ANY THIRD PERSON'S MISUSE, NEGLECT,
IMPROPER INSTALLATION OR TESTING, UNAUTHORIZED ATTEMPTS TO REPAIR OR MODIFY, OR ANY OTHER CAUSE BEYOND
THE RANGE OF THE INTENDED USE, OR BY ACCIDENT, FIRE, LIGHTNING, OR OTHER HAZARD.
LIMITATION OF LIABILITY
TO THE FULL EXTENT ALLOWED BY LAW, 3COM ALSO EXCLUDES FOR ITSELF AND ITS SUPPLIERS ANY LIABILITY, WHETHER
BASED IN CONTRACT OR TORT (INCLUDING NEGLIGENCE), FOR INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL, OR
PUNITIVE DAMAGES OF ANY KIND, OR FOR LOSS OF REVENUE OR PROFITS, LOSS OF BUSINESS, LOSS OF INFORMATION OR
DATA, OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE,
USE, PERFORMANCE, FAILURE, OR INTERRUPTION OF ITS PRODUCTS, EVEN IF 3COM OR ITS AUTHORIZED RESELLER HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, AND LIMITS ITS LIABILITY TO REPAIR, REPLACEMENT, OR REFUND OF THE
PURCHASE PRICE PAID, AT 3COM’S OPTION. THIS DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED IF ANY
REMEDY PROVIDED HEREIN SHALL FAIL OF ITS ESSENTIAL PURPOSE.
DISCLAIMER
Some countries, states, or provinces do not allow the exclusion or limitation of implied warranties or the limitation of incidental
or consequential damages for certain products supplied to consumers or the limitation of liability for personal injury, so the
above limitations and exclusions may be limited in their application to you. When the implied warranties are not allowed to be
excluded in their entirety, they will be limited to the duration of the applicable written warranty. This warranty gives you
specific legal rights which may vary depending on local law.
GOVERNING LAW
This Limited Warranty shall be governed by the laws of the State of California, U.S.A. excluding its conflicts of laws principles