E. Install the luminaire C. Mount the stand tube A. Mount the rollers Manufactured for WARNING: Static charge. If the PA-cable is not installed, the tripod equipment may get statically charged and the charge may get transferred to the patient. GS 900 Procedure Light Mobile Stand Installation Instructions CAUTION: Equipment damage. If the nose fastening is not properly inserted and the stand tube has not been bolted, the stand can fall. Specifications 2 Electrical Input 100-240 V ~50-60 Hz, 1.25A max 1 Environmental Transport / storage 4 2 158°F (70°C) 2 75% 3 Approvals Warnings and cautions WARNING: This product may only be assembled by a technician or a comparably qualified person. WARNING: Read and understand these instructions prior to use of this product. Failure to understand the operating requirements for this product may result in injury to yourself, the patient or may damage the instrument. Grab the front end of the spring arm and slowly pull it down until it reaches the stop. 2. Remove the plug and the protective cover from the spring arm opening. Discard the plug. 3. Push the plastic sleeve on the spring arm far enough to cover the slots. 1 3 B. Align power socket enclosure to base WARNING: Operator injury. The spring arm, which is compressed, can jump backward and result in injuries. During the installation of the luminaire, ensure that no one is within swiveling range of the spring arm. Note: Ensure that the stand tube is inserted so that the recess in the tube is seated in the flange of the base, and that the stand base can not be rotated. 1 1. Unscrew the winged screw with the spring washer (1) from the stand tube. 4. Push in the luminaire and the securing segment completely into the slots, ensuring that the securing segment is securely in the groove. 2. Insert the stand tube (2) so that the recess in the tube is seated in the flange of the base and can not be rotated. 5. Turn the plastic sleeve 180 degrees and turn the brake screw until the luminaire is completely installed and friction is applied. 3. Ensure a secure seating. 6. Check for a secure seating of the luminaire. 4. Screw in and tighten the winged screw and spring washer. 2 E D 1. 4 WARNING: Do not operate this product in the presence of flammable anesthetics or other flammable substances in combination with air, oxygen-enriched environments, or nitrous oxide; explosion can result. Assembly overview -13°F (-25°C) 3 1 Manual part no. 715400 Ver B. 500 - 1060 hPa D. Mount the spring arm The CE mark on this product indicates that it has been tested and conforms with the provisions noted in the 93/42/EEC Medical Device Directive. E212032 ONDAL Industrietechnik GmbH Wellastr. 6 D-36088 Huenfeld Germany Phone: ++49 / 6652 / 81-600 Fax: ++49 / 6652 / 81-392 WARNING: Operator or patient injury. Ensure that you only use the supplied securing element. Never use another part to mount the luminaire. 1 4 2 3 Tighten screw (2x). M4x8 3 B, C A 1. Unscrew the cross-slotted screw, pull the cover forward and move it up to take it out. 2. Insert the spring arm pin, place the disk, and secure them with the retaining ring. Ensure that the retaining ring fits into the pin groove. CAUTION: Equipment damage. Without the disk installed, the retaining ring may loosen and the spring arm may fall out of the joint. Always install the disk. 3. Make the electrical connection. 4. Attach the cover and screw in the cross-slotted screw. ONDAL part no. 1541411
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement