ER30G, ER30GI

Document # PG05-001

30” wide, Epicure

All Gas Range

Electrical Circuit required

120 Vac, 60 Hz, 15 Amps., dedicated, grounded

Total Connected

Load

4.0 Amps. @ 120 Vac,

60 Hz

ELEctRIcAL REqUIREmENts

®

Revised 05/25/10 Page 1/3

PLANNING

GUIDE

warning

Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information.

This appliance must be installed in accordance with the accompanying installation instructions.

All tolerances ±1/16” (±1.6mm) unless otherwise noted.

45 9/16” (1157mm)

28 9/16” (725mm)

27 1/16” (687mm)

26 1/8” (664mm)

24” (610mm)

1 1/8” (29mm)

Front of open door

Front of handle

Front edge of bullnose

Front panel

Rear of front panel

Backguard thickness

NOTE: Neither model is compatible with a raised vent.

1 9/16”

(40mm)

Product width:

29 7/8” (759mm)

Grates extend

1” above trim

9” (229mm)

Backguard***

ER30GI:

2” (51mm)

Partial stainless steel side panel

3” (76mm)

ER30G:

Full stainless steel side panels

3” (76mm)

Backguard***

6” (152mm)

Backguard*

35”

(889mm) to

37 1/8”

(943mm)

1 3/4” (44mm) Backguard**

* Standard on model ER30G

Optional on model ER30GI, NOT compatible with self-rimming installations

** Standard on model ER30GI

Optional on model ER30G

*** Optional on both models, NOT compatible with self-rimming installations

ER30G is designed for freestanding installations. ER30GI is designed for installation in a recessed cabinet or island. ER30G is

NOT equipped for self-rimming installation.

ER30G/ER30GI

OvERALL DEPth DImENsIONs - sIDE vIEw

Specifications subject to change without notice.

Install all appliances according to accompanying installation instructions.

www.Dacor.com Phone: (800) 793-0093

5.1

Document # PG05-001

B

ER30G, ER30GI

30” wide, Epicure

®

All Gas Range

Revised 05/25/10 Page 2/3

PLANNING

GUIDE

All tolerances +1/16” -0 (+1.6mm, 0) unless otherwise noted.

a* B c

30 1/16” (764mm)

30” (762mm) Minimum

36” (914mm) Recommended

37 1/8” (943mm)

Maximum

* See the cutout dimensions below for self-rimming installations nOTE: Self-rimming kit is included with model Er30gi.

The self-rimming kit allows the trim to overlap the counter top on the sides and back.

13” (330mm)

Max.

4

18” (457mm)

Min.

1, 4

Non-combustible surface along back wall recommended

30” (762mm)

Min.

1 A

Top of finished counter

10” (254mm Min.

to combustible side walls above the range

(both sides)

Note 2

C

Suggested location of utilities 3

1 Vertical to combustible surface from range grate level

2 Cabinet/countertop depth is at discretion of customer but cabinet face SHALL NOT protrude further than rear of front panel. See product dimesions.

3 Consult local code for exact location requirements.

4 Not applicable for cabinets more than a horizontal distance of 10” (254mm) from the edge of the range.

sLIDE-IN cUtOUt DImENsIONs

10” Min. (254mm) to any combustibles above counter both sides non comubustible rear wall recommended

10” Min. (254mm) to any combustibles above counter both sides rear wall or countertop edge

3/4” Min. (19mm)

Countertop overhang

24”

(610mm) below countertop

Cabinet face below countertop overhang to width of cabinets

Countertop Height: Min: 34 3/4” (883mm)

Max: 36 7/8” (937mm)

Countertop Thickness: Max: 1 5/8” (41mm)

Countertop overhang

2 1/8” (54mm) Max. sELf-RImmING cUtOUt DImENsIONs - cAbINEt DEPth ExActLY 24 INchEs

(ER30GI ONLY)

Specifications subject to change without notice.

Install all appliances according to accompanying installation instructions.

29 1/4” (743mm) countertop opening cabinet opening below countertop

Cabinet face below countertop

Notch countertop overhang to width of cabinets

Countertop Height: Min: 34 3/4” (883mm)

Max: 36 7/8” (937mm)

Countertop Thickness: Max: 1 5/8” (41mm)

24 1/8”

(613mm)

Countertop overhang

2 1/8” (54mm) Max. sELf-RImmING cUtOUt DImENsIONs - cAbINEt DEPth GREAtER thAN 24 INchEs

(ER30GI ONLY) www.Dacor.com Phone: (800) 793-0093

5.2

Document # PG05-001

ER30G, ER30GI

30” wide, Epicure

®

All Gas Range

Revised 05/25/10 Page 3/3

PLANNING

GUIDE

12 1/2”

(318 mm) to

14 5/8”

(371 mm)

2 5/8”

(67 mm) bAck Of RANGE gas

Type

Natural

LP gaS SUPPLY PrESSUrE rEQUirEMEnTS

Manifold

Pressure* (wC)

Min. gas Supply

Pressure (wC)

Max. input

Pressure

5”

10”

6”

11”

1/2 p.s.i.

1/2 p.s.i.

iMPOrTanT: The information above is for reference only. If the above data does not agree with the product data label, use the data on the product data label on top of the kick plate below the door (remove the door according to the installation instructions to view it).

The gas connection is located on the back of the unit as shown. Use a

1/2" male NPT to connect to the regulator.

CL

12” (305mm)

2 1/2”

(64mm)

3 1/2”

(89mm)

CL

1” (25mm)

UtILItY cLEARANcE bEhIND RANGE

Specifications subject to change without notice.

Install all appliances according to accompanying installation instructions.

www.Dacor.com Phone: (800) 793-0093

5.3

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement