ME-AGS wiring diagram –
For MQ Power (Whisperwatt Generators DAC-7000SS Diesel Generators)
Input DC voltage jumper
(set to battery
bank voltage) inside
Dip-switch configuration
(Portable Mode*)
5 amp fuse
Generator
12V
Battery
5 amp fuse
Start
Relay
+
-
C
2 1 4 3
Gen Run Signal
(input to pin 2 must be 10 to 40
DC volts only while generator is running); can be the generator hourmeter or a 12vdc pilot/run light
Battery
Bank
(monitored for gen turn on)
0 1 2 3
Gen
Hour Meter
On Relay
+ C
NO NC NO NC
3
4
5
6
7
8
9
2
1 11
10
NO NC
+
-
C
C
NO NC
50 AC
30
Starter
Switch
19
OFF
ON
PREHEAT
START
30 19 AC 50
Preheat Relay 1 Preheat Relay 2
Start Relay and Preheat Relay 2 = SPDT 65 Amp, 12 VDC coil relay;
On Relay = DPDT 65 Amp, 12 coil relay; Preheat Relay 1 =
RTE-P2 Timer made by IDEC.
ME-AGS Relay Timing for Portable Mode*
GEN AND POWER I/O
Relay 1
(pins 5 & 6)
Relay 2
(pins 6 & 7)
Start
RUN TIME
HOURS
Off
Delay Time
Start Time
Time Between Start attempts
Total Start Attempts
4 Sec.
10 Sec.
2 min.
4
* to enable Portable Mode, the ME-AGS must be revision 3.2 or higher
Magnum Energy, Inc. provides this diagram to assist in the installation of the Auto-Generator Start controller.
Since the use of this diagram and the conditions or methods of installation, operation and use are beyond the control of Magnum Energy, Inc., we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of the installation, operation and use of this unit.
10-3-2007