advertisement
FL-2H, FL-2L
Frequency ® Lavatory System – FL-Series
• ADA & TAS Compliant (lower or "concave" stations only)
• Patented Molded One-Piece Design with Integral Bowls
• Constructed of Terreon ® or Terreon ® RE Solid Surface Material
• Trap and Transition Cover Enclosure
• Includes Capacitive Sensing Faucet
• Optional Soap Dispenser and Plug-in Transformer
FL-2H
Specifications
With its patented design, the multi-height Frequency Lavatory System comfortably provides hand-washing access for adults, children, and those with disabilities. The
"convex" or higher station provides a more ergonomically correct position for ablebodied users while the "concave" or lower stations can be mounted to meet ADA or
TAS guidelines. Accommodating one to two users at a time, the FL-Series features a solid surface countertop with a one-of-a-kind integral bowl. The unique bowl, with integral solid surface overflow allows for greater knee clearance than other barrier free fixtures. The Frequency Lav System includes a "no-drip" edge and comes equipped with centershank battery-operated, capacitive sensing faucets. Faucet includes an anti-rotation 4" trim plate. Optional deck-mounted soap dispensers and plug-in transformers are available.
Construction
Counter Top/Bowl
Constructed of Terreon, a densified solid surface material composed of polyester resin, or TerreonRE, a densified solid surface material composed of a bio-based resin and preconsumer recycled granules. Terreon and TerreonRE are resistant to chemicals, stains, burns and impact. Surface damage can be easily repaired with everyday cleansers or fine grit abrasives. Terreon and TerreonRE are certified by NAHB to meet
ANSI Z124.3, Z124.6 and ANSI/ICPA SS-1. Terreon and TerreonRE are GREENGUARD ® certified as low-emitting materials.
Trap Cover Enclosure
The trap and transition cover of the Frequency Lav System not only conceals plumbing and electrical connections, but also reduces time needed for installation and maintenance. Trap and transition cover are made from high impact polymer.
Mounting
The FL-Series includes heavy gauge stainless steel mounting brackets, eliminating the need for additional specifications and/or casework beneath the countertop. All
Frequency Lavatory Systems meet or exceed industry standards for load testing.
Certified to
NSF/ANSI 372
Verify all rough-in dimensions prior to installation.
Consult local and national codes. Conformity and compliance to local and national codes is the responsibility of the installer.
Page 1 of 7 2/12/2016
This information is subject to change without notice.
Bradley_Sink_Frequency_FL-2L_2H
FL-2L
Code Compliance and Certifications
ANSI Standards
Terreon and TerreonRE are certified by NAHB to meet ANSI Z124.3, Z124.6 and ANSI/
ICPA SS-1.
cUPC Approval
Frequency Lav Systems are Uniform Plumbing Code (UPC), International Plumbing
Code (IPC) and National Plumbing Code of Canada (NPC) approved through the
International Association of Plumbing and Mechanical Officials (IAPMO). Manufactured in compliance with IGC 156, CSA B45 Series (R08) & ASME A112.18.1/CSA B125.1.
This plumbing fixture is designed for hand washing only. It is not Intended to dispense water for human consumption through drinking or for preparation of food or beverages.
Standard product selections contained within this document are third party
CERTIFIED to NSF/ANSI 372 meeting the Lead-Free content requirement.
Any product configured with custom options will be COMPLIANT with NSF/
ANSI 372 meeting the Lead-Free content requirement.
Standard Height Mounting
The concave or lower hand washing stations are designed to be mounted at various heights to comply with all ADA guidelines on reaches and clearances. To comply with
ADA, the rim height at the outside edge of the lower or concave station must be 34" max. above the finished floor. To be completely ADA compliant, the Frequency Lav
System must be equipped with ADA-compliant faucets and trap cover enclosure.
The convex hand washing stations do not meet ADA Accessibility Guidelines.
Always check local codes for compliance.
Juvenile Height Mounting
The concave hand washing stations are designed to be mounted at various heights to comply with all ADA and TAS guidelines on reaches and clearances. To comply with ADA for children, the rim height at the outside edge of the concave station must not exceed 31". Source: ADA Accessibility Guidelines for Buildings and Facilities
(ADAAG) as amended through September 2002.
To comply with Texas Accessibility Standards for children, the concave (lower) hand washing stations must be mounted so the rim height at the outside edge does not exceed 30" or 32" based on age or grade level. For more information, contact the Texas
Department of Licensing and Regulation.
© 2016 Bradley
P.O. Box 309, Menomonee Falls, WI 53052-0309
800 BRADLEY (800 272 3539) +1 262 251 6000 bradleycorp.com
FL-2H, FL-2L
Frequency ® Lavatory System – FL-Series
Standard Equipment
Models FL-2H & FL-2L
Multi-level deck with two lavatories, heavy gauge, stainless steel mounting brackets and two battery-operated faucets described below. Trap and transition covers to enclose the following fittings: offset drain; P-trap; continuous waste with end outlet; flexible stainless steel supply connections; and ASSE 1070 Navigator ® thermostatic mixing valve with stop valves.
Activation Controls
Capacitive Sensing Technology
The Aerada 1200 Series CS faucet creates an omnidirectional detection zone utilizing capacitive sensing technology. The capacitive sensing field triggers faucet activation only when a significant change in the capacitive field occurs. Only human presence will create a significant change in the capacitive field. As such, inanimate objects will not trigger faucet activation. The faucet is unaffected by varying skin tones, other infrared presence and soap scum build-up.
Valve
The electronically activated motor driven valve provides reliable performance since there are few moving parts. The valve includes an in-line filter to trap debris and is unaffected by most chemicals and minerals found in municipal water supplies. Valve features a factory-set maximum water run-on duration of 15 seconds. Valve control module features a manual override control for applications requiring periodic flushing of the water lines. The valve and electronics are enclosed in a water-resistant housing mounted below the fixture.
Flow Control/Rate
Operating water pressure range is 20–80 psi. Flow regulator keeps flow rate constant at all pressures. The flow is laminar at a rate of .5 gpm.
Optional Equipment
Models FL-2H & FL-2L
Liquid soap dispenser and 100–120 VAC plug-in transformer (to convert battery operated faucets).
Backing Information
Metal Studs
Drywall
12"
(305mm)
16"
(406mm)
66"
(1676mm)
Securely fasten the plywood to at least (3) metal studs
(plywood to equal thickness of drywall, ½" minimum)
25"
(635mm)
Use 3 ⁄
8
" toggle bolts and washers to secure the support brackets to the plywood (2) places.
Verify all rough-in dimensions prior to installation.
Consult local and national codes. Conformity and compliance to local and national codes is the responsibility of the installer.
Page 2 of 7 2/12/2016
This information is subject to change without notice.
Bradley_Sink_Frequency_FL-2L_2H
Protected by one or more of the following U.S. patents: D477,060, D507,634, D527,809,
D537,927, and 7,039,963. Other patents pending.
© 2016 Bradley
P.O. Box 309, Menomonee Falls, WI 53052-0309
800 BRADLEY (800 272 3539) +1 262 251 6000 bradleycorp.com
Dimensions – Top and Front Views
15"
(381mm)
FL-2H
FL-2L
37¾"
(959mm)
36"
(914mm)
30"
(762mm)
FL-2H, FL-2L
Frequency ® Lavatory System – FL-Series
30"
(762mm)
60" (1524mm)
7¾"
(197mm)
22"
(559mm)
30" (762mm) ADA
4"
(102mm)
15" (381mm)
ADA
34"
(864mm)
ADA
32"
(813mm)
12¼"
(311mm)
30" (762mm) ADA
15" (381mm)
ADA
4"
(102mm)
34"
(864mm)
ADA
32"
(813mm)
37¾"
(959mm)
36"
(914mm)
30"
(762mm)
12¼"
(311mm)
Verify all rough-in dimensions prior to installation.
Consult local and national codes. Conformity and compliance to local and national codes is the responsibility of the installer.
Page 3 of 7 2/12/2016
This information is subject to change without notice.
Bradley_Sink_Frequency_FL-2L_2H
© 2016 Bradley
P.O. Box 309, Menomonee Falls, WI 53052-0309
800 BRADLEY (800 272 3539) +1 262 251 6000 bradleycorp.com
Dimensions – Side Views
Standard
Height
22" (559mm)
19½" (495mm)
14"
(356mm)
34"
(864mm)
ADA Rim
Height
30"
(762mm)
37¾"
(959mm)
4½"
(114mm)
12¼"
(311mm)
FL-2H, FL-2L
Frequency ® Lavatory System – FL-Series
Juvenile
Height
Ages 6–12
22" (559mm)
19½" (495mm)
14"
(356mm)
31"
(787mm)
ADA Rim
Height
27"
(686mm)
4½"
(114mm)
34¾"
(883mm)
9¼"
(235mm)
TAS Height
Grades Pre-K through 5 or 6
22" (559mm)
19½" (495mm)
14"
(356mm)
30"
(762mm)
ADA Rim
Height
26"
(660mm)
TAS
TAS Height
Grades 6 through 8 or 9
22" (559mm)
19½" (495mm)
14"
(356mm)
4½"
(114mm)
33¾"
(857mm)
8¼" (210mm)
32"
(813mm)
ADA Rim
Height
28"
(711mm)
TAS
4½"
(114mm)
35¾"
(908mm)
10¼"
(260mm)
Verify all rough-in dimensions prior to installation.
Consult local and national codes. Conformity and compliance to local and national codes is the responsibility of the installer.
Page 4 of 7 2/12/2016
This information is subject to change without notice.
Bradley_Sink_Frequency_FL-2L_2H
© 2016 Bradley
P.O. Box 309, Menomonee Falls, WI 53052-0309
800 BRADLEY (800 272 3539) +1 262 251 6000 bradleycorp.com
Rough-Ins for FL-2H
½" (13mm)
FL-2H, FL-2L
Frequency ® Lavatory System – FL-Series
27 7 ⁄
8
" (708mm)
26" (660mm)
2 1 ⁄
8
" (54mm)
2 1 ⁄
8
" (54mm)
27 7 ⁄
8
" (708mm)
26" (660mm)
33"
(838mm)
30"
(762mm)
26 3 ⁄
8
"
(670mm)
1 3 ⁄
8
"
(35mm)
24"
(610mm)
17"
(432mm)
4"
(102mm)
Tempered
Line
20"
(508mm)
10"
(254mm)
15¾"
(400mm)
29"
(737mm)
32"
(813mm)
28"
(711mm)
31"
(787mm)
Code
A
B
H, C
3
Description
⁄
8
" Lav Deck Anchors with a Minimum Pull-Out Force of 1,000 lbs.
#10 Wall Anchors/Fasteners for Mounting Trap/Transition Covers
½" Nominal Copper Tubing Hot/Cold Supplies, Stub-Out 2" From Wall
D #10 Wall Anchors/Fasteners for Valve Mounting
E
W
110v GFI Protected Electrical Outlet
1½" NPT Drain, stub out 2" from wall (for combined drain)
NOTE: For individual drains, refer to page 9.
Rim Height
34"
32"
31"
30"
Vertical Height Adjustments for codes A–E,
H, C and W
0
Subtract 2"
Subtract 3"
Subtract 4"
Verify all rough-in dimensions prior to installation.
Consult local and national codes. Conformity and compliance to local and national codes is the responsibility of the installer.
Page 5 of 7 2/12/2016
This information is subject to change without notice.
Bradley_Sink_Frequency_FL-2L_2H
Fixture Style
Standard Height
TAS, Grades 6 through 8 or 9
TAS, Pre-K through Grades 5 or 6
Juvenile Height
Qty.
6
5
1
2
1
1
© 2016 Bradley
P.O. Box 309, Menomonee Falls, WI 53052-0309
800 BRADLEY (800 272 3539) +1 262 251 6000 bradleycorp.com
Rough-Ins for FL-2L
½" (13mm)
FL-2H, FL-2L
Frequency ® Lavatory System – FL-Series
27 7 ⁄
8
"
(708mm)
26" (660mm)
2 1 ⁄
8
" (54mm)
2 1 ⁄
8
" (54mm)
27 7 ⁄
8
"
(708mm)
26" (660mm)
31"
(787mm)
28"
(711mm)
26 3 ⁄
8
"
(670mm)
24"
(610mm)
1 3 ⁄
8
"
(35mm)
17"
(432mm)
Tempered
Line
4"
(102mm)
20"
(508mm)
10"
(254mm)
15¾"
(400mm)
29"
(737mm)
32"
(813mm)
33"
(838mm)
30"
(762mm)
Code
A
B
H, C
3
Description
⁄
8
" Lav Deck Anchors with a Minimum Pull-Out Force of 1,000 lbs.
#10 Wall Anchors/Fasteners for Mounting Trap/Transition Covers
½" Nominal Copper Tubing Hot/Cold Supplies, Stub-Out 2" From Wall
D #10 Wall Anchors/Fasteners for Valve Mounting
E
W
110v GFI Protected Electrical Outlet
1½" NPT Drain, stub out 2" from wall (for combined drain)
NOTE: For individual drains, refer to page 9.
Rim Height
34"
32"
31"
30"
Vertical Height Adjustments for codes A–E,
H, C and W
0
Subtract 2"
Subtract 3"
Subtract 4"
Verify all rough-in dimensions prior to installation.
Consult local and national codes. Conformity and compliance to local and national codes is the responsibility of the installer.
Page 6 of 7 2/12/2016
This information is subject to change without notice.
Bradley_Sink_Frequency_FL-2L_2H
Fixture Style
Standard Height
TAS, Grades 6 through 8 or 9
TAS, Pre-K through Grades 5 or 6
Juvenile Height
Qty.
6
5
1
2
1
1
© 2016 Bradley
P.O. Box 309, Menomonee Falls, WI 53052-0309
800 BRADLEY (800 272 3539) +1 262 251 6000 bradleycorp.com
FL-2H, FL-2L
Frequency ® Lavatory System – FL-Series
Model Description
FL-2H Frequency Lavatory System, Double Station (high on left), includes battery-operated S53-315 faucets
FL-2L Frequency Lavatory System, Double Station (low on left), includes battery-operated S53-315 faucets
Standard Selections
(Must select one from each category)
Supply (select one):
Navigator Thermostatic Mixing Assembly (Hot & Cold Supplies - includes stops and supply hoses)
Single Tempered Line (includes stops and supply hoses)
Soap Dispenser (select one)
LSD Liquid Soap Dispenser Model 6334 (located to right of faucets)
No Soap Dispenser
Color of Terreon Bowl/Deck (select one)
Standard Colors
ALP-WHT
CHAR
DUNE†
GLACIER
LANNON
Alpine White
Avalanche
Mesa Bone
Charcoal Gray
Cobblestone
Driftwood
Designer White
Sand Dune
Empire Gray
Glacier
Graphite
Lannonstone
LONDON
MOONSTONE†
O-TAUPE
PEBBLE
PEP-WHT
POLAR†
SAND
S-CREEK
S-MIST
WHT-SAND
London Gray
Moonstone
Organic Taupe
Pebble Beach
Peppered White
Polar Ice
Sandtrap
Stone Creek
Silver Mist
White Sand
Designer Colors* (available at an additional charge)
ARC-CHIP Arctic Chip COFFEE
Riverstone
TerreonRE Colors* (available at an additional charge)
BIRCH-BARK Birch Bark MOONDUST
Dusk
Element Colors
SS-GRAY Soapstone Gray
Color of Trap Cover (select one)
Coal
OAT
CA-TAN
Coffee Bean
Moondust
Oat
Canyon Tan
Optional Selections
Transformer:
PT 110-120VAC plug-in adapter to convert battery-operated S53-315 faucet
*Non-cancelable, non-returnable
† This color contains large, randomly distributed chips.
Verify all rough-in dimensions prior to installation.
Consult local and national codes. Conformity and compliance to local and national codes is the responsibility of the installer.
Page 7 of 7 2/12/2016
This information is subject to change without notice.
Bradley_Sink_Frequency_FL-2L_2H
© 2016 Bradley
P.O. Box 309, Menomonee Falls, WI 53052-0309
800 BRADLEY (800 272 3539) +1 262 251 6000 bradleycorp.com
advertisement