58UVB PERFORMANCE

t

96

95% AFUE UPFLOW ONLY VARIABLE---SPEED

CONDENSING GAS FURNACE

Series 120, Input Rates 60,000 thru 120,000 Btuh

Product Data

A05097

Comfort Heat

t

THE ULTIMATE IN HEATING

COMFORT...

The Carrier Performance t 96 with Comfort Heatt technology achieves the optimum combination of comfort and efficiency.

The Performance t 96 achieves up to 95 percent Annual Fuel

Utilization Efficiency (AFUE). Efficient performance is enhanced through the variable--speed design. To maintain ideal comfort,

Comfort Heat technology automatically adjusts the heating level, maximizing the use of low heating levels that produce near silent furnace operation while meeting the exact heating needs. This unit is designed to keep the indoor temperature within 1 degree of the thermostat set point. Because it operates in low heat most of the time, the Performance 96 uses up to 80% less power than single--capacity furnaces.

In addition to providing ultimate comfort, the Performance 96 has a sealed combustion system. This system brings combustion air to the furnace and vents flue gases outside the furnace in a safe manner. Because it is sealed, operational noise is minimal. A sealed combustion system also means fewer cold drafts and less air infiltration.

The Performance 96 is available in 5 heat/airflow combinations.

The unit has an upflow only design. The Performance 96 can be installed as a Direct vent/2--pipe only. The Performance 96 is not approved for installation in mobile homes, recreational vehicles, or outdoor use.

The variable speed makes the Performance 96 ideal for use with split--system cooling, including 2--stage units.

A Carrier electronic air cleaner, humidifier, Thermidistat t, comfort ventilator, and Comfort Zone t II will provide year--round comfort and efficiency.

Designed for durability, comfort, and reliability, the Performance

96 is the ultimate in versatile, efficient comfort.

PERFORMANCE 96 FEATURES/

BENEFITS

IdealHumidity Technology

The IdealHumidity system actively controls both temperature and humidity in your home to provide the best comfort all year long.

Other systems depend on heating or cooling to manage the moisture in the air. But IdealHumidity gives you the right amount of humidity, day and night, even in mild weather. No other

manufacturer can do this! IdealHumidity saves energy, too. By keeping humidity under control, you can set your thermostat to stay comfortable and save energy—up to 20% off your cooling costs!

Comfort Heat Technology

On the coldest days of the year, the Performance 96 Furnace has the capacity to heat your home. On moderate days when less heat is required, this furnace will regulate itself to a lower capacity—providing a comfortable home and minimizing operating costs.

The patented algorithm adjusts the low--heat operating time to match the indoor conditions.

Reliable Heat Exchanger Design

The primary heat exchanger is made of aluminized steel for corrosion resistance. The patented Serpentuff t condensing heat exchanger cells are laminated with polypropylene for greater resistance to corrosion and epoxy coated externally to prevent oxidation. This breakthrough in heating technology helps extend the life of the furnace for years of dependable performance. The heat exchanger is positioned in the furnace to extract additional heat.

1

Power Heat t Igniter

Carrier’s unique SiN igniter is not only physically robust but it is also electrically robust. It is capable of running at line voltage and does not require complex voltage regulators as do other brands.

This unique feature further enhances the reliability of

Performance 96 gas furnace and continues Carrier’s tradition of technology leadership and innovation in providing a reliable and durable product.

ComfortFan t Technology

Improves comfort all year long by allowing you to select the continuous fan speed right at the compatible thermostat.

SmartEvap t Technology

Allows your system to reduce summertime humidity levels by nearly 10% cover standard systems.

ComfortHeat t Adaptive Control Center

The microprocessor control center features state--of--the--art combustion, temperature, and airflow control to maximize comfort while operating at peak efficiency.

Combustion control is obtained by taking the appropriate inducer motor RPM readings when the low--and high--fire pressure switches are made. Using this information, the microprocessor main--information, the microprocessor maintains a consistent air--to--fuel ratio independent of vent sizing and conditions.

The first cycle after power reset provides 16 minutes of low heat before switching to high heat unless the room thermostat has been satisfied. Subsequent thermostat cycles provide anywhere from 0 to 16 minutes of low heat depending on the length of the previous thermostat cycle.

Airflow control is accomplished by using a technique involving the microprocessor and blower motor. The static load on the air delivery system is measured each heating cycle.

The microprocessor then uses this information to deliver correct airflow independent of variations in system restrictions. (For example, dirty filter or zone damper changes during a cycle.)

A special dehumidification function allows direct input from a thermidistat or humidistat. This input adjusts system airflow for greater humidity removal and increased cooling comfort during summer months.

Direct Venting

The Performance 96 must be installed as a 2--pipe (direct vent) furnace or with combustion air supplied from a well--ventilated attic or crawl space.

Electronic Variable--Speed Motors

ECM Motors (Electronically Commutated Motor) provide variable--speed operation to optimize comfort levels in the home year round. They are also more economical to operate than standard motors.

Sealed Combustion System

Performance 96 brings in combustion air from outside the furnace, which results in especially quiet operation.

Insulation

Foil--faced insulation in heat exchanger section of the casing minimizes heat loss.

Insulated Blower Compartment

The acoustical insulation reduces air and motor noise for quiet operation.

Monoport Burners

The burners are finely turned for smooth, quiet combustion and economical operation.

Bottom Closure

Factory--installed for side return; easily removable for bottom return.

Blower Access Panel Switch

Automatically shuts off 115--V power to furnace whenever blower access panel is opened.

Quality Registration

The Performance 96 is engineered and manufactured under an

ISO 9001 registered quality system.

Certifications

The Performance 96, Model 58UVB units are CSA (AGA and

CGA) design certified for use with natural and propane gases.

The furnace is factory--shipped for use with natural gas. A CSA listed gas conversion kit is required to convert furnace for use with propane gas. The efficiency is AHRI efficiency rating certified. The Performance 96 meets California Air Quality

Management District emission requirements.

2

10

11

12

6

7

9

8

1

2

3

4

5

13

14

6

16

15

17

18

19

A02287

NOTES:

1. The 58UVB Furnace is built for use with natural gas. The furnace can be converted for propane gas with a factory ---authorized and listed accessory conversion kit.

2. Control location and actual controls may be different than shown above.

1. Burner sight glass for viewing burner flame.

2. Burner assembly (inside). Operates with energy saving, inshot burners and hot surface igniter for safe, dependable heating.

3. Combustion--air intake connection to ensure contaminate-free air (right or left side).

4. Redundant 2--stage gas valve. Safe, efficient. Features one gas control with two internal shutoff valves.

5. Junction box for 115--v electrical power supply.

6. Vent outlet. Uses PVC pipe to carry vent gases from the furnaces’s combustion system (right or left side).

7. Secondary condensing heat exchanger (inside). Wrings out more heat through condensation. Constructed with patented polypropylene--laminated steel to ensure durability.

8. Pressure switches ensure adequate flow of flue products through furnace and out vent system.

9. Inducer motor. Pulls hot flue gases through the heat exchangers, maintaining negative pressure for added safety.

10. Condensate drain connection.

Collects moisture condensed during combustion process.

11. Heavy--duty blower. Circulates air across the heat exchangers to transfer heat into the home.

12. Air filter and retainer. May be used for side return application.

13. Rollout switch (manual reset) to prevent overtemperature.

14. Primary serpentine heat exchanger (inside). Stretches fuel dollars with the S--shaped heat flow design. Solid construction of corrosion--resistant aluminized steel means reliability.

15. Three--amp fuse provides electrical and component protection.

16. Light emitting diodes (LEDs) on control center. Code lights are for diagnosing furnace operation and service requirements.

17. Comfort Heat Control center.

18. Blower access panel safety interlock switch.

19. Transformer (24v) behind control center provides low-voltage power to furnace control center and thermostat.

3

MODEL NUMBER NOMENCLATURE

58UVB 060 --- --- --100 14

Cooling Airflow

(400 CFM per 12,000 Btuh)

14 --- 1400 CFM

20--- 2000CFM

Deluxe Upflow only

Variable--- Speed Direct--- Vent (2--- Pipe) and

Condensing Gas Furnace

Input Rates

060 --- 60,000 Btuh

080 --- 80,000 Btuh

100 --- 100,000 Btuh

120 --- 120,000 Btuh

Series

CARRIER ACCESSORIES

DESCRIPTION PART NO.

Vent Termination Kit (Bracket Only for 2 Pipes)

Concentric Termination Kit (Single Exit)

Condensate Freeze Protection Kit

Germicidal Air Purifier

Condensate Neutralizer Kit (obtained thru RCD)

2--- in. — KGAVT0101BRA

3--- in. — KGAVT0201BRA

2--- in. — KGAVT0701CVT

3--- in. — KGAVT0801CVT

KGAHT0101CFP

Model GAPA

P908--- 0001

Electronic Air Cleaner

Mechanical Air Cleaner

Humidifier

Heat Recovery Ventilator

Energy Recovery Ventilator

UV Lights

EZ Flex Media Filter with end caps --- 16--- in. (9 pack)

EZ Flex Media Filter with end caps --- 20--- in. (9 pack)

EZ Flex Media Filter with end caps --- 24--- in. (6 pack)

Replacement EZ Flex Filter --- 16--- in. (10 pack)

Replacement EZ Flex Filter --- 20--- in. (10 pack)

Replacement EZ Flex Filter --- 24--- in. (10 pack)

Exterior Filter Rack --- Universal, 1--- in. (adjustable from 14--- in. to

24--- in.) with filter

Unframed Filter 1--- in. — 16 x 25

Unframed Filter 1--- in. — 20 x 25

Unframed Filter 1--- in. — 24 x 25

Model EACA

Model FILCAB or

EZXCAB

Model HUM

Model HRV

Model ERV

Model UVL

EXPXXLMC0016

EXPXXLMC0020

EXPXXLMC0024

EXPXXFIL0016

EXPXXFIL0020

EXPXXFIL0024

KGAFR0301ALL

KGAFR0306ALL (6 pack)

KGAWF1301UFR

KGAWF1306UFR (6 pack)

KGAWF1401UFR

KGAWF1406UFR (6 pack)

KGAWF1501UFR

KGAWF1506UFR (6 pack)

UNIT SIZE

060--- 14 080--- 14 080--- 20 100--- 20 120--- 20

X X X X X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

S

X

X

X

X

X

X

X

X

X

X

X

X

X

X

S

X

X

X

X

X

X

X

X

X

X

X

X

X

X

S

X

X

X

X

X

X

X

X

X

X

X

X

X

X

4

CARRIER ACCESSORIES CONTINUED

DESCRIPTION PART NO.

Natural--- To--- Propane Gas Conversion Kit (Single Kit)*

Propane--- To--- Natural Gas Conversion Kit (Single Kit)

ECM Motor Simulator (simulates the ECM blower and inducer motor to aid troubleshooting)

Door Gasket Kit

Advanced Product Monitor (software and hardware to link pc laptop to control board)

KGANP4601ALL

KGAPN3901ALL

KGASD0301FMS

KGBAC0110DGK

KGAFP0301APM

ECM Control Replacement Module --- 1/2 HP

ECM Control Replacement Module --- 1 HP

Gas Orifice Kit Size 42 (Qty 50)

Gas Orifice Kit Size 43 (Qty 50)

Gas Orifice Kit Size 44 (Qty 50)

Gas Orifice Kit Size 45 (Qty 50)

Gas Orifice Kit Size 46 (Qty 50)

Gas Orifice Kit Size 47 (Qty 50)

Gas Orifice Kit Size 48 (Qty 50)

Gas Orifice Kit Size 54 (Qty 50)

HK44EA123

HK52EA123

KGAHA0150N42

KGAHA0250N43

KGAHA0350N44

KGAHA0450N45

KGAHA0550N46

KGAHA1550N47

KGAHA850N48

KGAHA0850P54

Gas Orifice Kit Size 55 (Qty 50)

KGAHA0750P55

Gas Orifice Kit Size 56 (Qty 50) KGAHA0850P56

Gas Orifice Kit Size 1.25mm (Qty 50) KGAHA05750125

Gas Orifice Kit Size 1.30mm (Qty 50) KGAHA5750130

* Factory ---authorized and field ---installed. Gas conversion kits are CSA (AGA/CGA) recognized.

S 16 x 25 filters suitable for side return on all furnace sizes.

UNIT SIZE

060--- 14 080--- 14 080--- 20 100--- 20 120--- 20

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X X X

X X X

See Installation Instructions for model, altitude, and heat value usages.

A06514

5

THERMOSTAT AND ZONING CONTROL OPTIONS

NON ---PROGRAMMABLE THERMOSTAT SELECTION

TC ---NAC or TP ---NAC

TC ---NHC or TP ---NHC

For use with 1 speed Air Conditioner ---

_F/_C, Auto Changeover

For use with 1 speed Air Conditioner ---

_F/_C, Auto Changeover

TP ---NRH* For use with 2 speed Air Conditioner ---

_F/_C, Auto Changeover

* Model HP & 2 Stage thermostat must be field converted to air conditioner operation.

TP ---PAC

TP ---PHP*

TP ---PRH*

TB ---PAC

TP ---PRH

TP ---PRH

{

}

PROGRAMMABLE THERMOSTAT SELECTION

For use with 1 speed Air Conditioner --_F/_C, Auto Changeover, 7---Day

Programmable

For use with 1 speed Heat Pump ---

_F/_C, Auto Changeover, 7---Day

Programmable

For use with 2 speed Air Conditioner ---

_F/_C, Auto Changeover, 7---Day

Programmable

For use with 1 speed Air Conditioner ---

_F/_C, Auto Changeover, 5---2

Programmable

For use with two--- stage applications ---

_F/_C, Auto Changeover, 7---Day

Programmable

For multi--- use/stage configurations --_F/_C, Auto Changeover 7---Day

Programmable

* Model HP & 2 Stage thermostat must be field converted to air conditioner operation.

{

Hybrid Heat ¥ thermostat is used with furnace and heat pump application.

} Thermidistat can be configured for heating, cooling, and Hybrid Heat applications. It must be configured for each specific application.

ZONECC3Z(AC/HP)01

ZONECC2KIT01 ---B

ZONECC4KIT01 ---B

ZONECC8KIT01 ---B

ZONING CONTROL SELECTION

WeatherMaker Two--- Zone Kit

Comfort Zone II--- B 2--- Zone Kit

Comfort Zone II--- B 4--- Zone Kit

Comfort Zone II--- B 8--- Zone Kit

6

Heat Exchangers

A92505

MODEL PLUG

CONNECTOR

SW1 SETUP

SWITCHES AND

BLOWER OFF-

DELAY

AIR CONDITIONING

(A/C) AIRFLOW

SETUP SWITCHES

FACTORY TEST

CONNECTOR

CONTINUOUS FAN

(CF) AIRFLOW

SETUP SWITCHES

24-V THERMOSTAT

TERMINALS

HUMIDIFIER

TERMINAL (24-VAC

0.5 AMP MAX.

ACRDJ AIR

CONDITIONING

RELAY DISABLE

JUMPER

STATUS AND COMM

LED LIGHTS

3-AMP FUSE

TRANSFORMER 24-VAC

CONNECTIONS

PL3 ECM BLOWER

HARNESS

CONNECTOR

115-VAC (L2) NEUTRAL

CONNECTIONS

PL1 LOW VOLTAGE MAIN

HARNESS CONNECTOR

EAC-1 TERMINAL

(115-VAC 1.0 AMP MAX.)

115-VAC (L1) LINE

VOLTAGE CONNECTIONS

PL2 HOT SURFACE

IGNITER & INDUCER

MOTOR CONNECTOR

A09679

Control Center

X

Inducer Assembly

A02286

A93086

Concentric Vent (Direct Vent/2--Pipe Only)

A concentric vent kit allows vent and combustion--air pipes to terminate through a single exit in a roof or side wall.

One pipe runs inside the other allowing venting through the inner pipe and combustion air to be drawn in through the outer pipe.

7

®

A97152

Electronic or Mechanical

Air Cleaner

Cleans the air of smoke, dirt, and many pollens commonly found. Saves decorating and cleaning expenses by keeping carpets, furniture, and drapes cleaner.

Electronic Air Cleaner is shown.

A01484

Humidifier

By adding moisture to winter dry air, a Carrier humidifier can often improve comfort and keeps woodwork, wallpaper, and paint in better condition.

Moisturizing household air also helps to retain normal body heat and provides comfort at lower temperature.

A97432

Controls: Thermostats and Zoning

Available in programmable and non--programmable models, Carrier thermostats maintain a constant, comfortable temperature level in the home.

For the ultimate in home comfort, Carrier’s 2--, 4--, or 8--zone systems allow temperature control of individual “zones” of the home. This is accomplished through a series of electronic dampers and remote room sensors. The

4--zone system is shown.

A04336

Energy/Heat Recovery

Ventilator

Carrier’s energy or heat recovery ventilators exhaust stale indoor air and provide fresh outdoor air to the home while minimizing heat loss and humidity level. Especially useful for today’s tighter constructed houses.

Energy recovery ventilator is shown.

D E

S I G N

C

E R

T I F I E

D

C E RT I F I E D

Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.

Always Ask For

8

PHYSICAL DATA

DESCRIPTION

Direct--- Drive Motor Hp (ECM)

Motor Full Load Amps

RPM (Nominal)—Speeds

Blower Wheel Diameter X Width (in.)

Filter Size (in.) Nominal A (Washable)

Shipping Weight (lb)

Limit Control

Heating Blower Control (Off Delay)

Burners (Monoport)

Gas Connection Size

Gas Valve (Redundant) Manufacturer

Minimum Inlet Pressure (in. wc)

Maximum Inlet Pressure (in. wc)

Ignition Device

UNIT SIZE

060--- 14 080--- 14 080--- 20 100--- 20 120--- 20

1/2

7.7

1/2

7.7

1

12.8

1

12.8

1

12.8

10 X 7 11 X 10

Variable 250 — 1300

11 X 10 11 X 10 11 X 10

(1) 16 X 25 X 1 (1) 20 X 25 X 1 (1) 20 X 25 X 1 (1) 20 X 25 X 1 (1) 24 X 25 X 1

170 182 204 203 234

3

SPST

Selectable 90, 120, 150, or 180 SEC Intervals

4 4 5

1/2--- in. NPT

White--- Rodgers

4.5 (Natural Gas)

13.6 (Natural Gas)

Hot Surface --- SiN

6

PERFORMANCE DATA

UNIT SIZE

DESCRIPTION

060--- 14 080--- 14 080--- 20 100--- 20 120--- 20

Certified Temp Rise Range (

Certified Ext Static Pressure (ESP) (in. wc)

Airflow CFM*

Output Capacity Btuh

AFUE%

}

_F)

} (ICS)

Low

High

Heating

Cooling

Heating Low

Heating High

Cooling (Max)

Low

High

40—70

35—65

0.12

0.50

635 (700

{)

1070

1400

37,000

56,000

95.0

40—70

40—70

0.15

0.50

860 (945

{)

1245

1372

50,000

75,000

95.0

40—70

1975

50,000

75,000

95.0

40—70

35—65

0.15

45—75

0.20

45—75

0.20

0.50

0.50

0.50

880 (970

{)

1105 (1215

{) 1325 (1455{)

1490 1525 1900

1950

63,000

94,000

95.0

40—70

2060

75,000

113,000

95.0

Input Btuh**

Low

High

39,000

60,000

52,000

80,000

52,000

80,000

65,000

100,000

78,000

120,000

* Airflow shown is for bottom only return ---air supply with factory ---supplied 1 ---in. washable filter(s). For air delivery above 1800 CFM, see Air Delivery table for other options.

{ Low heat CFM when low---heat rise adjustment switch (SW1---3) on furnace control is used.

} AFUE and capacity in accordance with U.S. Government DOE test procedures.

** Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 2% for each 1000 ft above sea level. In Canada, derate the unit 5% for elevations from 2000 to 4500 ft above sea level.

9

AIR DELIVERY -- CFM (BOTTOM RETURN WITH FILTER)*

Unit Size Operating Mode

CFM Airflow

Setting

External Static

Pressure Range*

0.1

0.2

External Static Pressure (ESP) In. W.C.

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

060 ---14

††

††

††

Low Heat

High Heat

1 ---1/2 ---Ton A/C Cooling

2 ---Ton A/C Cooling

2 ---1/2 ---Ton A/C Cooling

3 ---Ton A/C Cooling

3 ---1/2 ---Ton A/C Cooling

Maximum

635†

1070†

525

700

875

1050

1225

1400

0 ---0.50

0 ---1.0

0 ---0.50‡

0 ---0.50‡

0 ---1.0‡

0 ---1.0

0 ---1.0

0 ---1.0

635 635 625 615 615

1070 1070 1070 1070 1070 1070 1070 1070 1065 1045

525 525

700 700

510

695

495

680

465

680

850 870 875 875 870 860 845 825 810 805

1050 1050 1050 1050 1050 1050 1050 1050 1050 1045

1225 1225 1225 1225 1225 1225 1225 1225 1225 1205

1400 1400 1400 1400 1400 1400 1400 1400 1380 1325

080 ---14***

††

††

††

Low Heat

High Heat

1 ---1/2 ---Ton A/C Cooling

2 ---Ton A/C Cooling

2 ---1/2 ---Ton A/C Cooling

3 ---Ton A/C Cooling

3 ---1/2 ---Ton A/C Cooling

Maximum

900†

1245†

525

700

875

1050

1225

1400

0 ---0.50

0 ---1.0

0 ---0.50‡

0 ---0.50‡

0 ---1.0‡

0 ---1.0‡

0 ---1.0‡

0 ---1.0‡

860 870 880 885 885 880 870 855 850 845

1245 1245 1245 1245 1245 1245 1245 1235 1190 1145

515 495

685 680

490

670

475

665

465

665

830 840 850 860 860 855 840 830 825 820

1050 1050 1050 1050 1050 1045 1040 1025 1015 1000

1225 1225 1225 1225 1225 1225 1225 1225 1185 1140

1400 1400 1400 1400 1375 1325 1280 1235 1190 1145

080 ---20***

††

††

††

Low Heat

High Heat

2 ---Ton A/C Cooling

2 ---1/2 ---Ton A/C Cooling

3 ---Ton A/C Cooling

3 ---1/2 ---Ton A/C Cooling

4 ---Ton A/C Cooling

5 ---Ton A/C Cooling

Maximum

880†

1500†

700

875

1050

1225

1400

1750

2000

0 ---0.50

0 ---1.0

0 ---0.50‡

0 ---0.50‡

0 ---1.0‡

0 ---1.0‡

0 ---1.0‡

0 ---1.0

0 ---1.0

880 880 880 875 880

1485 1495 1500 1500 1500 1500 1500 1485 1475 1465

670 640

870 875

635

865

630

865

630

865

1050 1045 1040 1045 1045 1050 1050 1050 1045 1040

1225 1225 1225 1225 1225 1225 1225 1225 1225 1225

1330 1345 1360 1375 1380 1380 1380 1370 1365 1355

1750 1750 1750 1750 1750 1750 1745 1725 1700 1685

2000 2000 2000 2000 1975 1955 1920 1870 1820 1770

100 ---20***

††

††

††

Low Heat

High Heat

2 ---Ton A/C Cooling

2 ---1/2 ---Ton A/C Cooling

3 ---Ton A/C Cooling

3 ---1/2 ---Ton A/C Cooling

4 ---Ton A/C Cooling

5 ---Ton A/C Cooling

Maximum

1110†

1525†

700

875

1050

1225

1400

1750

2000

0 ---0.50

0 ---1.0

0 ---0.50‡

0 ---0.50‡

0 ---1.0‡

0 ---1.0‡

0 ---1.0‡

0 ---1.0

0 ---1.0

1105 1110 1110 1110 1110 1110 1110 1110 1110 1110

1525 1525 1525 1525 1525 1525 1525 1510 1495 1470

700 690 690 690 690

835 845 855 860 865

1050 1050 1050 1050 1050 1050 1050 1050 1050 1050

1170 1190 1205 1220 1225 1225 1225 1225 1225 1225

1400 1400 1400 1400 1400 1400 1400 1400 1400 1375

1735 1740 1735 1735 1725 1720 1710 1695 1680 1660

1995 1985 1980 1965 1950 1935 1910 1885 1860 1815

120 ---20

††

††

Low Heat

High Heat

2 ---Ton A/C Cooling

2 ---1/2 ---Ton A/C Cooling

3 ---Ton A/C Cooling

1330†

1900†

700

875

1050

0 ---1.0

0 ---1.0

0 ---0.50‡

0 ---0.50‡

0 ---1.0‡

1325 1330 1330 1330 1330 1330 1330 1330 1330 1325

1900 1900 1900 1900 1900 1885 1875 1860 1840 1815

700 700 700 700 695

870 875 875 865 870

1025 1035 1045 1050 1050 1050 1050 1050 1040 1025

3 ---1/2 ---Ton A/C Cooling

4 ---Ton A/C Cooling

5 ---Ton A/C Cooling

1225

1400

1750

0 ---1.0‡

0 ---1.0‡

0 ---1.0‡

1210

1385

1745

1210

1400

1730

1210

1400

1735

1225

1400

1735

1225

1400

1740

1225

1400

1735

1225

1400

1730

1225

1395

1725

1225

1375

1710

1225

1370

1685

6 ---Ton A/C Cooling 2100 0 ---1.0

2100 2100 2080 2065 2060 2045 2030 2000 1960 1895

Maximum 2100 0 ---1.0

2100 2100 2080 2065 2060 2045 2030 2000 1960 1895

* Actual external static pressure (ESP) can be determined by using the fan laws (CFM 2 proportional to ESP); such as, a system with 1750 CFM at 0.5 ESP would operate at high ---heating airflow of 1500 CFM at 0.37 ESP and low ---heating airflow of 880 CFM at 0.13 ESP.

{ All heating CFMs are when low---heat rise adjustment switch (SW1---3) and comfort/efficiency adjustment switch (SW1---4) are OFF.

}

Ductwork must be sized for high ---heating CFM within the operational range of ESP.

** Wattage data provided is for the circulating blower with bottom return and does not include draft inducer, accessories, or gas controls.

{{ Operation within the blank areas of the chart is not recommended because high---heat operation will be above 1.0 ESP.

*** All airflows on 21 in. casing size furnaces are 5% less on side return only installations.

10

CONCENTRIC VENT (DIRECT VENT/2--PIPE ONLY) (ALL MODEL SIZES)

B IN. DIA PVC

VENT/EXHAUST F

E

1 1/2

C IN. DIA

1 3 /

16

D

A

B IN. DIA PVC

INTAKE/COMBUSTION AIR

A97110

Dimensions (In / mm)

KIT PART NO.

KGAVT0701CVT

KGAVT0801CVT

A*

33--- 3/8 (847.7)

38--- 7/8 (987.4)

B

2 (50.8)

3 (78.2)

C

3--- 1/2 (88.9)

4--- 1/2 (114.3)

D

{{

16--- 5/8 (422.3)

21--- 1/8 (536.6)

E

6--- 1/4 (158.8)

7--- 3/8 (189.3)

F

5--- 3/4 (146.1)

6--- 1/2 (165.1)

* Dimension A will change proportionally as dimension D is lengthened or shortened.

{ Dimension D may be lengthened to 60 in. (1524 mm) maximum. Dimension D may also be shortened by cutting the pipes provided in the kit to 12 in. (304.8

mm) minimum.

CONDENSATE TRAP

BLOWER SHELF

CONDENSATE

TRAP (INSIDE)

ALTERNATE DRAIN

TUBE LOCATION

CONDENSATE TRAP

DRAIN TUBE LOCATION

UPFLOW APPLICATIONS

A06450

11

DIMENSIONS

26 15 ⁄

16

"

26 1 ⁄

4 "

(684 mm)

(667 mm)

24 1 ⁄

2

" (622 mm)

22 5 ⁄

16 " (567 mm)

2-IN. (51 mm) COMBUSTION-

AIR CONN

1 ⁄

2 -IN. (13mm) DIA

GAS CONN

. 2-IN (51mm)

VENT CONN

1 ⁄

2

-IN. DIA (13mm)

THERMOSTAT ENTRY

22 11 ⁄

16 "

(576 mm)

14 1 ⁄

2

TYP

"

(368 mm)

1 1 ⁄

4

" (32 mm)

1"

(25mm)

SIDE INLET

(591 mm)

23 1 ⁄

4

" TYP

SIDE INLET

26 15 ⁄

16 " TYP

(684 mm)

13 / 16 "

(21 mm)

7 ⁄

8

-IN. DIA (22mm)

POWER CONN

30 13 ⁄

16 "

(783 mm)

9 7 ⁄

16

TYP

"

(240 mm)

29

7 ⁄

8 -IN. DIA (22mm)

ACCESSORY

POWER ENTRY

CONDENSATE

DRAIN TRAP

LOCATION

(ALTERNATE

UPFLOW)

27 5 ⁄

8

"

(702 mm)

27 9 ⁄

16 "

TYP

(700 mm)

24 1 ⁄

2

"

(622 mm)

17 5 ⁄

16 "

(439 mm)

11 ⁄

16

TYP

"

(754 mm)

33 1 ⁄

4

TYP

"

(845 mm)

32 5 ⁄

8

TYP

"

(829 mm)

CONDENSATE

DRAIN LOCATION

(UPFLOW)

11 /

16

"

(17 mm)

AIRFLOW

A

D

OUTLET

INLET

E

13 / 16 "

(21 mm)

CONDENSATE DRAIN

ALTERNATE

1 ⁄

2

-IN. DIA GAS CONN

(14 mm)

9 ⁄

16 "

TYP

11 /

16

"

(17 mm)

30 1 ⁄

2 "

(775 mm)

18 1 ⁄

4 "

(464 mm)

CONDENSATE

DRAIN LOCATION

(UPFLOW)

NOTES: 1. Minimum return-air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturerís recommendations for equivalent diameters.

2. Minimum return-air opening at furnace: a. For 800 CFM–16-in. (406mm) round or 14 1 /

2

.

b. For 1200 CFM–20-in. (508mm) round or 14 1 /

2

(368mm)x 19 1 /

2

-in. (495mm) rectangle

.

.

c. For 1600 CFM–22-in. (559mm) round or 14 1 /

2

(368mm)x 23 1 /

4

-in.(591mm) rectangle d. For airflow requirements above 1800 CFM, see Air Delivery table in literature for specific use of single side inlets. The use of both side inlets, a combination of 1 side and the bottom, or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM.

28 1 ⁄

2 " (724 mm)

26 15 ⁄

16 " (684 mm)

26 1 ⁄

4 " (667 mm)

22 5 ⁄

16 " (567 mm)

19" (483 mm)

OUTLET

13

5

8

16

"

" (21 mm)

(16 mm)

2-IN. (51mm)

COMBUSTION-AIR CONN

1 ⁄

2 -IN. DIA (13mm)

GAS CONN

7 ⁄

8 -IN. DIA (22mm)

POWER CONN

5 ⁄

16

"

(16 mm)

1 ⁄

2

-IN. DIA (13 mm)

THERMOSTAT ENTRY

2-IN. (51 mm)

VENT CONN

39 7 ⁄

8 "

(1013 mm)

22 11 ⁄

16 "

(576 mm)

SIDE INLET

(25 mm)

1"

22 1 ⁄

4 " TYP

(565 mm)

24 3 ⁄

16

"

BOTTOM INLET

(614 mm)

7 ⁄

16 " (11 mm)

11 ⁄

16 " (25 mm)

A09680

Dimensions -- In. (mm)

A

17--- 1/2 (445)

21 (533)

21 (533)

21 (533)

24--- 1/2 (622)

D

15--- 7/8 (403)

19--- 3/8 (492)

19--- 3/8 (492)

19--- 3/8 (492)

22--- 7/8 (581)

E

16 (406)

19--- 1/2 (495)

19--- 1/2 (495)

19--- 1/2 (495)

23 (584)

UNIT SIZE

060--- 14

080--- 14

080--- 20

100--- 20

120--- 20

ELECTRICAL DATA

UNIT SIZE

Unit Volts--- Hertz --- Phase

Operating Voltage Range (Min --- Max)*

Maximum Unit Amps

Minimum Wire Size

Maximum Wire Length (ft) {

Maximum Fuse or Ckt Brk (Amps) }

Transformer (24v)

External Control Power Available

060 ---14

8.9

14

31

15

080 ---14

8.9

14

31

15

Heating

Cooling

* Permissible limits of the voltage range at which the unit will operate satisfactorily.

{ Length shown is as measured 1 way along wire path between unit and service panel for maximum 2% voltage drop.

} Time---delay type is recommended.

080 ---20

115--- 60--- 1

104--- 127

13.8

12

32

20

40va

25va

34va

100 ---20

13.8

12

32

20

120 ---20

13.8

12

32

20

12

TYPICAL WIRING SCHEMATIC

FIELD 24-VOLT WIRING

FIELD 115-, 208/230-, 460-VOLT WIRING

FACTORY 24-VOLT WIRING

FACTORY 115-VOLT WIRING

FIVE

WIRE

THREE-WIRE

HEATING-

ONLY

NOTE 2

W C Y R G

1-STAGE

THERMOSTAT

TERMINALS

FIELD-SUPPLIED

FUSED DISCONNECT

208/230- OR

460-VOLT

THREE

PHASE

BLK BLK

W2

WHT

GND

115-VOLT FIELD-

SUPPLIED

FUSED

DISCONNECT

COM

WHT

W/W1

Y/Y2

JUNCTION

BOX

CONTROL

BOX

R

G

24-VOLT

TERMINAL

BLOCK

FURNACE

NOTE 1

NOTES: 1.

2.

3.

CONDENSING

UNIT

GND

208/230-

VOLT

SINGLE

PHASE

Connect Y/Y2-terminal as shown for proper operation.

Some thermostats require a "C" terminal connection as shown.

If any of the original wire, as supplied, must be replaced, use same type or equivalent wire.

A95236

13

MAXIMUM ALLOWABLE PIPE LENGTH (FT / M)

UNIT SIZE

(BTUH)

60,000

ALTITUDE

80,000

100,000 0 to 2000

120,000

UNIT SIZE

(BTUH)

60,000

80,000

2001 to

3000

100,000

120,000

UNIT SIZE

(BTUH)

60,000

ALTITUDE

80,000

100,000

ALTITUDE

3001 to

4000

120,000

UNIT SIZE

(BTUH)

60,000

ALTITUDE

80,000

4001 to

5000‡

100,000

120,000

UNIT SIZE

(BTUH)

60,000

ALTITUDE

80,000

5001 to

6000‡

100,000

120,000

*See notes on next page.

Direct Vent (2 ---Pipe Only)

Termination

Type

2 Pipe or 2--- In.

Concentric

2 Pipe or 2--- In.

Concentric

2 Pipe or 2--- In.

Concentric

2 Pipe or 3--- In.

Concentric

Termination

Type

2 Pipe or 2--- In.

Concentric

2 Pipe or 2--- In.

Concentric

2 Pipe or 2--- In.

Concentric

2 Pipe or 3--- In.

Concentric

Termination

Type

2 Pipe or 2--- In.

Concentric

2 Pipe or 2--- In.

Concentric

2 Pipe or 2--- In.

Concentric

2 Pipe or 3--- In.

Concentric

Termination

Type

2 Pipe or 2--- In.

Concentric

2 Pipe or 2--- In.

Concentric

2 Pipe or 2--- In.

Concentric

2 Pipe or 3--- In.

Concentric

Pipe Dia

(IN.)*

1--- 1/2

2

1--- 1/2

2

2

2--- 1/2

2--- 1/2 one disk

3 one disk

3 one disk†

2

1--- 1/2

2

2

2--- 1/2

3 one disk

3 one disk†

Pipe Dia

(IN.)*

1--- 1/2

2

1--- 1/2

2

2

2--- 1/2

Pipe Dia

(IN.)*

1--- 1/2

2

1--- 1/2

2

2

2--- 1/2

3 one disk

3 one disk†

Pipe Dia

(IN.)*

1--- 1/2

3 one disk†

Termination

Type

2 Pipe or 2--- In.

Concentric

2 Pipe or 2--- In.

Concentric

2 Pipe or 2--- In.

Concentric

2 Pipe or 3--- In.

Concentric

Pipe Dia

(IN.)*

1--- 1/2

2

1--- 1/2

2

2

2--- 1/2

3 one disk†

NUMBER OF 90

_ ELBOWS

1 2 3 4 5 6

50 / 15.2

45 / 13.7

40 / 12.9

35 / 10.7

30 / 9.1

25 / 7.6

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

30 / 9.14

25 / 7.6

20 / 6.1

15 / 4.6

10 / 3.0

5 / 1.5

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

45 / 13.7

40 / 12.9

35 / 10.7

30 / 9.1

25 / 7.6

20 / 6.1

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

10 / 3.0

NA NA NA NA NA

35 / 10.7

30 / 9.1

15 / 4.8

NA NA NA

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

NUMBER OF 90

_ ELBOWS

1 2 3 4 5 6

45 / 13.7

40 / 12.9

35 / 10.7

30 / 9.14

25 / 7.6

20 / 6.1

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

26 / 7.9

21 / 6.4

16 / 4.9

11 / 3.4

6 / 1.8

NA

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

40 / 12.2

35 / 10.7

30 / 9.1

25 / 7.6

20 / 6.1

15 / 4.6

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

31 / 9.4

26 / 7.9

12 / 3.7

NA NA NA

63 / 19.2

62 / 18.9

62 / 18.9

61 / 18.6

61 / 18.6

61 / 18.6

NUMBER OF 90

_ ELBOWS

1 2 3 4 5 6

42 / 12.8

37 / 11.2

32 / 9.8

27 / 8.2

22 / 6.7

17 / 5.2

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

25 / 7.6

20 / 6.1

15 / 4.6

10 / 3.0

5 / 1.5

NA

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

38 / 11.6

33 / 10.1

28 / 8.5

23 / 7.0

18 / 5.5

13 / 4.0

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

29 / 8.8

24 / 7.3

10 / 3.0

NA NA NA

59 / 18.0

59 / 18.0

58 / 17.8

57 / 17.4

57 / 17.4

56 / 17.0

NUMBER OF 90

_ ELBOWS

1 2 3 4 5 6

40 / 12.2

35 / 10.7

30 / 9.1

25 / 7.6

20 / 6.1

15 / 9.6

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

23 / 7.0

18 / 5.5

13 / 4.0

8 / 2.4

NA NA

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

68 / 20.7

36 / 11.0

31 / 9.4

26 / 7.9

21 / 6.4

16 / 4.8

11 / 3.4

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

56 / 17.1

55 / 16.8

54 / 16.5

53 / 6.2

52 / 15.8

52 / 15.8

1 2

NUMBER OF 90

_ ELBOWS

3 4 5 6

37 / 11.3

32 / 9.8

27 / 8.2

22 / 6.7

17 / 5.2

12 / 3.7

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

22 / 6.7

17 / 5.2

12 / 3.7

7 / 2.1

NA NA

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

68 / 20.7

63 / 19.2

33 / 10 28 / 8.5

23 / 7.0

18 / 5.5

13 / 4.0

8 / 2.4

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

70 / 21.3

53 / 16.2

52 / 15.8

50 / 15.2

49 / 14.9

48 / 14.6

47 / 14.3

14

MAXIMUM ALLOWABLE PIPE LENGTH (FT / M) (CONTINUED)

Direct Vent (2--Pipe Only)

Termination

Type

2 Pipe or 2--- In.

Concentric

2 Pipe or 2--- In.

Concentric

2 Pipe or 2--- In.

Concentric

NUMBER OF 90 _ ELBOWS

ALTITUDE

6001 to 7000‡

UNIT SIZE

(BTUH)

60,000

80,000

100,000

Pipe Dia

(IN.)*

1--- 1/2

2

1--- 1/2

2

2

2--- 1/2

1 2 3 4 5 6

35 / 10.7

30 / 9.1

25 / 7.6

20 / 6.1

15 / 4.6

10 / 3.0

70 / 21.3

70 / 21.3

68 / 20.7

67 / 20.4

66 / 20.11

64 / 19.5

20 / 6.1

15 / 4.6

10 / 3.0

5 / 1.5

NA

70 / 21.3

70 / 21.3

68 / 20.7

67 / 20.4

62 / 18.9

NA

57 / 17.4

31 / 9.4

26 / 7.9

21 / 6.4

16 / 4.9

70 / 21.3

70 / 21.3

68 / 20.7

67 / 20.4

11 / 3.4

66 / 20.1

6 / 1.8

64 / 19.5

120,000

2 Pipe or 3--- In.

Concentric

3 one disk† 49 / 14.9

48 / 14.6

47 / 14.3

45 / 13.7

44 / 13.4

43 / 13.1

ALTITUDE

7001 to 8000‡

UNIT SIZE

(BTUH)

60,000

80,000

100,000

Termination

Type

2 Pipe or 2--- In.

Concentric

2 Pipe or 2--- In.

Concentric

2 Pipe or 2--- In.

Concentric

Pipe Dia

(IN.)*

1--- 1/2

2

1--- 1/2

2

2

2--- 1/2

1

32 / 9.8

2

27 / 8.2

NUMBER OF 90

_ ELBOWS

3

22 / 6.7

4

17 / 5.2

66 /20.1

65 / 19.8

63 / 19.2

62 / 18.9

18 / 5.5

13 / 4.0

8 / 2.4

NA

5

12 / 3.7

60 / 18.3

NA

66 / 20.1

65 / 19.8

63 / 19.2

62 / 18.9

29 / 8.8

24 / 7.3

19 / 5.8

14 / 4.3

66 / 20.1

65 / 19.8

63 / 19.2

62 / 18.9

57 / 17.4

9 / 2.7

60 / 18.3

6

7 / 2.1

59 / 18.0

NA

52 / 15.8

NA

59 / 18

120,000

2 Pipe or 3--- In.

Concentric

3 one disk† 46 / 14.0

44 / 13.4

43 / 13.1

41 / 12.5

40 / 12.2

38 / 11.6

ALTITUDE

UNIT SIZE

(BTUH)

60,000

Termination

Type

2 Pipe or 2--- In.

Concentric

Pipe Dia

(IN.)*

1--- 1/2

2

1--- 1/2

2

2

2--- 1/2

1

30 / 9.1

2

25 / 7.6

NUMBER OF 90

_ ELBOWS

3

20 / 6.1

4

15 / 4.6

62 / 18.9

60 / 17.8

58 / 17.7

56 / 17.1

17 / 5.2

12 / 3.1

7 / 2.1

NA

5

10 / 3.0

55 / 16.8

NA

6

5 / 1.5

53 / 16.2

NA

8001 to 9000‡

80,000

100,000

2 Pipe or 2--- In.

Concentric

2 Pipe or 2--- In.

Concentric

62 / 18.9

60 / 18.3

58 / 17.7

56 / 17.1

27 / 8.2

22 / 6.7

17 / 5.2

12 / 3.7

62 / 18.9

60 / 18.3

58 / 17.7

56 / 17.1

51 / 15.5

7 / 2.1

55 / 16.8

46 / 14.0

NA

53 / 16.2

120,000

2 Pipe or 3--- In.

Concentric

3 one disk† 43 / 13.1

41 / 12.5

39 /11.9

37 / 11.3

35 / 10.7

34 / 10.4

ALTITUDE

9001 to

10000‡

UNIT SIZE

(BTUH)

60,000

80,000

100,000

Termination

Type

2 Pipe or 2--- In.

Concentric

2 Pipe or 2--- In.

Concentric

2 Pipe or 2--- In.

Concentric

Pipe Dia

(IN.)*

1--- 1/2

2

1--- 1/2

2

2

2--- 1/2

1

27 / 8.2

15 / 4.6

57 / 17.4

24 / 7.3

57 / 17.4

2

22 / 6.7

10 / 3.0

55 / 16.8

19 / 5.8

55 / 16.8

NUMBER OF 90

_ ELBOWS

3

17 / 5.2

5 / 1.5

53 / 16.2

14 / 4.3

53 / 16.2

4

12 / 3.7

57 / 17.4

55 / 16.8

53 / 16.2

51 / 15.5

NA

51 / 15.5

9 / 2.7

51 / 15.5

5

7 / 2.1

49 / 14.9

NA

46 / 14.0

NA

49 / 14.9

6

NA

47 / 14.3

NA

41 / 12.5

NA

47 / 14.3

120,000

2 Pipe or 3--- In.

Concentric

3 one disk† 39 / 11.9

37 / 11.3

35 / 10.7

33 / 10.1

31 / 9.5

29 / 8.8

* Disk usage ---Unless otherwise stated, use perforated disk assembly (factory ---supplied in loose parts bag).

{ Wide radius elbow.

} Vent sizing for Canadian installations over 4500 ft (1370m) above sea level are subject to acceptance by the local authorities having jurisdiction.

NA---Not Allowed; pressure switch will not make contact.

NOTES:

1. Do not use pipe size greater than those specified in table or incomplete combustion, flame disturbance, or flame sense lockout may occur.

2. Size both the combustion ---air and vent pipe independently, determine the smallest diameter allowed by the table for each pipe, then use the larger diameter for both pipes.

3. Assume two 45 _ elbows equal one 90_ elbow. Long radius elbows are desirable and may be required in some cases.

4. Elbows and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count.

5. The minimum pipe length is 5 ft for all applications.

15

MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH -- FT (M)

WITH INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT*

UNIT SIZE

WINTER DESIGN

TEMPERATURE

MAXIMUM PIPE

IN. (MM) 0

INSULATION THICKNESS†

3/8 1/2 3/4 1

060 ---14

080 ---14

080 ---20

100 ---20

120 ---20

20

_F / ---6.7_C

0

_F / ---17.8_C

--- 20

_F / ---28.9_C

20

_F / ---6.7_C

0

_F / ---17.8_C

--- 20

_F / ---28.9_C

20

_F / ---6.7_C

0 _F / ---17.8_C

--- 20 _F / ---28.9_C

20

_F / ---6.7_C

0

_F / ---17.8_C

--- 20

_F / ---28.9_C

2 (51)

2 (51)

2 (51)

2 (51)

2 (51)

2 (51)

2--- 1/2 (64)

2--- 1/2 (64)

2--- 1/2 (64)

3 (76)

3 (76)

3 (76)

30 (9.1)

16 (4.9)

9 (2.7)

37 (11.2)

20 (6.1)

11 (3.4)

41 (12.5)

21 (6.4)

11 (3.4)

49 (14.9)

26 (7.9)

15 (4.6)

55 (16.8)

33 (10.1)

23 (7.0)

65 (19.8)

39 (11.9)

27 (8.3)

70 (21.3)

42 (12.8)

28 (8.5)

70 (21.3)

51 (15.5)

35 (10.7)

61 (18.6)

38 (11.6)

26 (7.9)

70 (21.4)

45 (13.7)

31 (9.4)

70 (21.3)

48 (14.6)

33 (10.1)

70 (21.3)

58 (17.7)

40 (12.2)

70 (21.3)

46 (14.0)

33 (10.1)

70 (21.3)

55 (16.8)

39 (11.9)

70 (21.3)

59 (18.0)

41 (12.5)

70 (21.3)

70 (21.3)

50 (15.2)

70 (21.3)

53 (16.2)

38 (11.6)

70 (21.3)

63 (19.2)

45 (13.7)

70 (21.3)

68 (20.7)

49 (14.9)

70 (21.3)

70 (21.3)

59 (18.0)

* Pipe length (ft/m) specified for maximum pipe lengths located in unconditioned spaces. Pipes located in unconditioned space cannot exceed total allowable pipe length as specified in Table.

† Insulation thickness based on R value of 3.5 per in.

CLEARANCE TO COMBUSTIBLES

16

(LIT. TOP)

A09681

TYPICAL INSTALLATIONS

OUTDOOR UNIT

COMBUSTION AIR PIPE

A/C COIL VENT PIPE

HUMIDIFIER

AIRFLOW

ELECTRONIC

AIR CLEANER

FRONT OF

FURNACE

GAS-FIRED

WATER HEATER

A06511

17

GUIDE SPECIFICATIONS

GENERAL

System Description

Furnish a ______________________ (upflow) gas--fired condensing furnace for use with natural gas or propane (factory-authorized conversion kit required for propane); furnish cold air return plenum; furnish external media cabinet for use with accessory media filter or standard filter.

Quality Assurance

Unit will be designed, tested and constructed to the current ANSI

Z 21.47/CSA 2.3 design standard for gas--fired central furnaces.

Unit will be third party certified by CSA to the current ANSI Z

21.47/CSA 2.3 design standard for gas--fired central furnaces.

Unit will carry the CSA Blue Star

R and Blue FlameR labels.

Unit efficiency testing will be performed per the current DOE test procedure as listed in the Federal Register.

Unit will be certified for capacity and efficiency and listed in the latest AHRI Consumer’s Directory of Certified Efficiency

Ratings.

Unit will carry the current Federal Trade Commission Energy

Guide efficiency label.

Delivery, Storage, and Handling

Unit will be shipped as single package only and is stored and handled per unit manufacturer’s recommendations.

Warranty (for inclusion by specifying engineer)

U.S. and Canada only. Warranty certificate available upon request.

Equipment

Blower Wheel and ECM Blower Motor

Galvanized blower wheel shall be centrifugal type, statically and dynamically balanced. Blower motor of ECM type shall be permanently lubricated with sealed ball bearings, of _______hp, and have infinitely variable speed from 300--1300 RPM operating only when 24--VAC motor inputs are provided. Blower motor shall be direct drive and soft mounted to the blower scroll to reduce vibration transmission.

Filters

Furnace shall have reusable--type filters. Filter shall be ______ in.

(X) ________ in. An accessory highly efficient Media Filter is available as an option. _____________ Media Filter.

Casing

Casing shall be of .030 in. thickness minimum, pre--painted galvanized steel.

Performance 96

Two--Stage/Variable Speed Gas Furnace

58UVB

ECM Inducer Motor

ECM Inducer motor shall be variable speed design, soft mounted to assembly to reduce vibration transmission.

Primary Heat Exchangers

Primary heat exchangers shall be 3--Pass 20 gauge corrosion-resistant aluminized steel of fold--and--crimp sectional design and applied operating under negative pressure.

Secondary Heat Exchangers

Secondary heat exchangers shall be of a flow--through design having a patented interior laminate coating of polypropylene for greater corrosion resistance with fold--and--crimp design and applied operating under negative pressure.

Controls

Controls shall include a micro--processor--based integrated electronic control board with at least 16 service troubleshooting codes displayed via diagnostic flashing LED light on the control, a self--test feature that checks all major functions of the furnace, and a replaceable automotive--type circuit protection fuse.

Multiple operational settings available, including separate blower speeds for low heat, high heat, low cooling, high cooling and continuous fan. Continuous fan speed may be adjusted from the thermostat. Cooling airflow will be selectable between 350 or 400

CFM per ton of air conditioning. Features will also include temporary reduced airflow in the cooling mode for improved dehumidification when a Thermidistat is selected as the thermostat.

Operating Characteristics

Heating capacity shall be _________________ Btuh input;

______________ Btuh output capacity.

Fuel Gas Efficiency shall be 95% AFUE.

Air delivery shall be ________________ cfm minimum at 0.50

in. wc. external static pressure.

Dimensions shall be: depth_________in.; width __________in.; height___________in. (casing only). Height shall be

_________in. with A/C coil and _________________in. overall with plenum.

Electrical Requirements

Electrical supply shall be 115 volts, 60 Hz, single--phase

(nominal). Minimum wire size shall be ________AWG; maximum fuse size of HACR--type designated circuit breaker shall be _________ amps.

Special Features

Refer to section of the product data identifying accessories and descriptions for specific features and available enhancements.

Copyright 2010 Carrier Corp.

S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A.

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

18

Edition date: 09/10

Catalog No:58UVB---2PD

Replaces: 58UVB--1PD