BP601G1 Tech Sheet - Balboa Water Group

BP601G1 Tech Sheet - Balboa Water Group
BP601G1 Tech Sheet
Customer:
Balboa Water Group
Part Number:
56497-02
56498-02
56499-02
56562-01
Custom Box Overlay
□
3.0kW 800 Incoloy
3.0kW 825 Incoloy
3.0kW Titanium
2.0kW 800 Incoloy
Box Overlay Part Number N/A
CE System Model:
BP6-BP601G1-RCA-3.0KW
Software Version ID:
M100_206 V20.0
Software Version:
20.0
File Name:
BP601_20.0_BP601G1.hex
Configuration Signature:
0B27D3D6
Eng. Project Number:
4132
Base PCBA:
56500-02
Control Panels (See later pages for more information):
TP800
Version 3.1 and later (Version 3.13 or later required for bba™)
TP600CE
Version 2.7 and later - TP600 (non-CE) should not be used
TP400T
Version 2.7 and later
TP400W
Version 2.7 and later
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2009 Balboa Water Group.
Template 56377 10-05-12
1
56497-02/56498-02/56499-02/56562-01_97_B 04-15-14
System Revision History
Part #
EPN
Date
Originator Changes Made
56497
56498
56499
3899
05-13-13
BWG
BP601G1 initial draft
56497
56498
56499
N/A
06-12-13
BWG
Corrections to Tech Sheet
56497-01
56498-01
56499-01
4127
08-28-13
BWG
Issue found with Serialized Purge on one-pump-only Setups.
56497-02
56498-02
56499-02
4132
09-12-13
BWG
Update to latest software version.
56497-02
56498-02
56499-02
56562-01
4132
03-12-14
BWG
Updated to latest software version, adding topside-intergrated bba™ support. Released to production.
bba™ (Balboa Bluetooth Amp) connection is documented seperately.
bba™ is only integrated into graphic display panels (TP800, TP900 and spaTouch™). With TP600 the Aux button operation of bba™ must be used.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2009 Balboa Water Group.
Template 56377 10-05-12
2
56497-02/56498-02/56499-02/56562-01_97_B 04-15-14
Basic Functions Setup 1 - 6
Power Requirements:
Single Service [3 wires (line, neutral, ground)]
230VAC, 50/60Hz*, 1þ, 16A, (Circuit Breaker rating = 20A max.)
Single Service [3 wires (line, neutral, ground)]
230VAC, 50/60Hz*, 1þ, 32A, (Circuit Breaker rating = 40A max.)
*BP systems automatically detect 50Hz vs 60Hz.
System Ouputs:
Pump 1
230VAC
2-Speed
6.5A - 12A max
15-minute timer (30-minute timer for P1 Low in non-circ setups only)
Pump size is dependent on service available (16A vs. 32A), other equipment installed, and if A5 is set to ON for Special Amperage Rule B.
in Setups 1, 3, 5, this is the heater pump.
Must deliver 20 GPM through heater
NOTE: A circ pump cannot be used with a 2-speed pump in this system. See the BP601G2.
1 Speed in Setups in Setups 2, 4, 6
Pump 2
230VAC
1-Speed
6.5A - 12A max
15-minute timer
Pump size is dependent on service available (16A vs. 32A), other equipment installed, and if A5 is set to ON for Special Amperage Rule B.
Used in setups 1 & 2
Blower
230VAC
1-Speed
4A max
Used in Setup 3 & 4
Circ Pump
230VAC
1-Speed
2A max
Programmable Filtration Cycles + Polling
This is the heater pump in Setups 2, 4, 6.
Must deliver 20 GPM through heater
Ozone
230VAC
Spa Light
10VAC
A/V (Stereo) 230VAC
Heater
15-minute timer
.5A max
Slaved to Circ Pump in Circ Setups and to Pump 1 Low in Non-Circ Setups
On/Off
1A max
240-minute timer.
Hot
4A max
Always on
3.0kW @ 240VAC max
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2009 Balboa Water Group.
Template 56377 10-05-12
3
56497-02/56498-02/56499-02/56562-01_97_B 04-15-14
Hardware Setup
Wiring Diagram
BP601G1 PN 56497-02
MOVE WIRE TO CONNECT J2O TO J13 FOR BLOWER IN SETUPS 3 & 4
K1
120V
K4
120V
F2 3A 250V
T1
J109
K5
12VAC-B
J19
12VAC-A
J18
J8
J21
K7
230V
1þ
1x16A
1x32A
J100
J101
K12
J46
HEATER
J14
J108
J47
J16
WIFI
TRANSCEIVER
J33 OR J45
J5
J17
J28 AUX FRZ
HTR
DISBL
INSTEAD OF
SETUP #1,
THIS SYSTEM IS
CONFIGURED IN:
DEVICE
NETZSTROMVERSORGUNG 1/2-GESCHW.-PUMPE 1
ALIMENTATION POMPE 1 A 1/2 VITESSES 1/2-SPD PMP 1
J14
NETZSTROMVERSORGUNG 1-GESCHW.-PUMPE 2
ALIMENTATION POMPE 2 A 1 VITESSES 1-SPEED PUMP 2
J14 OPTION VENTILATEUR SPRUDELGEBLASE BLOWER
J15
10V BELEUCHTUNG ECLAIRAGE BAIN HYDRO SPA LIGHT
J21
KREISLAUF PUMPE POMPE DE CIRCULATION CIRC PUMP
J24
OZONGENERATOR GENERATOROZONE OZONE GENERATOR
J47
TV / AV
SETUP #
SENSOR A
3.0 kW HEATER
TORQUE RANGE FOR HEATER
CONNECTIONS: 30 TO 35 IN. LBS.
TORQUE RANGE FOR
MAIN TERMINAL BLOCK (TB1):
27-30 IN. LBS.
(31.1-34.5 kg cm)
SETUP #
CIRC PUMP
PUMP 1
PUMP 2
PUMP 3
BLOWER
TEMP SCALE
1
2
3
4
5
6
NONE
FILTERS + POLLING
NONE
FILTERS + POLLING
NONE
FILTERS + POLLING
2-SPEED
1-SPEED
2-SPEED
1-SPEED
2-SPEED
1-SPEED
1-SPEED
1-SPEED
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
1-SPEED
1-SPEED
NONE
NONE
°C
°C
°C
°C
°C
°C
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2009 Balboa Water Group.
Template 56377 10-05-12
4
ON POSITION
TEST MODE ON
ADD 1 HS PUMP WITH HEAT
ADD 2 HS PUMPS WITH HEAT
5 MIN HTR COOLDOWN (GAS)
SPECIAL AMPERAGE RULE ON
MEMORY RESET*
LOCATION
J8
SENSOR B
HEIZELEMENT
RADIATEUR
1
2
3
4
5
6
*SWITCH # 6 SHOULD BE SET TO OFF UPON FINAL INSTALLATION.
ALL UNUSED SWITCHES SHOULD BE OFF
J33
J29
VAC
USE COPPER CONDUCTORS ONLY.
EMPLOYER UNIQUEMENT
DES CONDUCTEURS DE CUIVRE.
S1 SWITCH #
TEST MODE OFF
DON’T ADD 1 HS PUMP W/HTR
DON’T ADD 2 HS PUMPS W/HTR
1 MIN HTR COOLDOWN (ELEC)
SPECIAL AMPERAGE RULE OFF
STORE SETTINGS*
J22
J45
GND
FOR SUPPLY CONNECTIONS,
USE CONDUCTORS SIZED ON THE
BASIS OF 60°C AMPACITY BUT
RATED MINIMUM OF 90°C.
OFF POSITION
EXPANDER
F4 3A 250V
03-12-14
TP (MAIN) PANELS
J33 or J45
TEMP SENSORS
J23
SERIAL
LIGHT J15
J24
A/V
J52
AUX
J49
J50
J32
J38 J37 J48
J35 J34 J36
P2/BLWR
J43
K3
J30
J56
J31 J27
3
3
GRN
1
K6
K2
240V
6
J5 (A1-A4)
J25=HTR1 J26=HTR2
J27=HTR3 J30=TEST
J31=CE HTR SEL
J25 J26
OZONE
2
BLU
BRN
J20
J44
CIRC
J54
J55
J42
J39
J41
J53
1
2
J40
J12
TB1
ON 1
J51
F5 30A
2
(UNFUSED)
S1
PUMP 1
J56
J57
F6 0.125A 250V
F3 10A 250V
BLOWER
J13
AUX
56497-02/56498-02/56499-02/56562-01_97_B 04-15-14
Setup Reference Table
Setup #
Circ Pump
Pump 1
Pump 2
Pump 3
Blower
Temp Scale
1
None
2-Speed
1-Speed
None
None
°C
2
Programmable Filtration + Polling
1-Speed
1-Speed
None
None
°C
3
None
2-Speed
None
None
1-Speed
°C
4
Programmable Filtration + Polling
1-Speed
None
None
1-Speed
°C
5
None
2-Speed
None
None
None
°C
6
Programmable Filtration + Polling
1-Speed
None
None
None
°C
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2009 Balboa Water Group.
Template 56377 10-05-12
5
56497-02/56498-02/56499-02/56562-01_97_B 04-15-14
System is shipped in Setup 1
Changing Software Setups with TP800
Test Menu Access (S1, Switch 1 ON) Service Technician ONLY.
DANGER! HIGH VOLTAGE WILL BE ACCESSIBLE! SERVICE TECHNICIAN ONLY!
While the system is running, move DIP Switch 1 (on S1 on the Main circuit board) to ON.
The system will enter Test Mode.
Moving DIP Switch 1 to OFF will exit Test Mode.
1
6
S1
ON
Software Setups
Under the TEST Menu, the Setup screen will allow changing the
Setup from 1 to any number established by the Manufacturer.
Changing the Setup may require wiring changes as well.
102°F
Set: 104°F
8:32 PM
Ozone
Filter 1
High Range
Spa
Shortcuts
Settings
Test
Ready in Rest Mode
Heating
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2009 Balboa Water Group.
Template 56377 10-05-12
6
56497-02/56498-02/56499-02/56562-01_97_B 04-15-14
`
Test
Back
Setup
A/B Temps
Fault Log
Timeouts
Temp Limit
1 `
Off
`
Normal
Yes
Changing Software Setups with TP600/400
Test Menu Access (S1, Switch 1 ON) Service Technician ONLY.
DANGER! HIGH VOLTAGE WILL BE ACCESSIBLE! SERVICE TECHNICIAN ONLY!
While the system is running, move DIP Switch 1 (on S1 on the Main circuit board) to ON.
The system will enter Test Mode.
Moving DIP Switch 1 to OFF will exit Test Mode.
As soon as Switch #1 is placed
in the ON position, the temperature will show
“T” after it instead of F or C, indicating the
System is in Test Mode
Software Setups
Under the TEST Menu, the Setup screen will allow changing the Setup from 1 to any number established by the Manufacturer.
Changing the Setup may require wiring changes as well.
You will have 1 minute to complete the setup change after you manually exit Priming Mode. (Once familiar with the process,
the Setup change should take less than 15 seconds.)
When the panel displays RUN PMPS PURG AIR, press any Temperature button ONCE to exit Priming Mode.
You should see “---T” where the T indicates the system is in Test Mode.
READY
RANGE
Continued on Next Page.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2009 Balboa Water Group.
Template 56377 10-05-12
7
56497-02/56498-02/56499-02/56562-01_97_B 04-15-14
1
ON
6
S1
Changing Software Setups with TP600/400 Continued
Again, You will have 1 minute to complete the setup change after you manually exit Priming Mode.
Immediately after exiting Priming Mode, press this sequence of buttons: Warm*, Light, Warm, Warm, Warm, Warm. Continue to press Warm until the diplay
shows the Setup Number (S-01, S-02, etc.) you want to switch to. When the correct setup number is showing, press Light once, and the system will reset,
using the newly-selected Setup from that point on.
THIS SYSTEM IS
CONFIGURED AS
SETUP #
Move DIP Switch 1 to the OFF position to take the spa out of Test Mode. °F or °C will replace °T.
Using a permanent marker, write the Setup number on the Setup label mounted inside the system lid (right). This is very important to any service
person in the future who may need to replace a circuit board or system and needs to change the Setup on a replacement part while in the field.
NOTE: Changing the Setup may require wiring changes as well - refer to the wiring diagram or wiring diagram addendum.
Main Screen
READY
RANGE FLTR1
SET
RANGE
Key
The System will reset and go into Priming Mode if the Light Button
is pressed while anything other than the current setup is flashing.
If there is no change to the Setup Number (S-01, S-02, etc.),
the display returns to the SETP screen.
While the Set Temperature is
still flashing, press Light
TEST will now appear in
the LCD first.
Indicates Flashing or Changing Segment
Indicates Alternating or Progressive Message - every 1/2 second
A temperature button, used for “Action”
Light or dedicated “Choose” button, depending on control panel configuration
Waiting time - varies depending on function
SET
SET
SET
Several Setups can
exist in in this string
A dash (--) indicates the current Setup.
SET
When set to ON, Panel will display
alternate readings from
Senor A and Sensor B
on Main Screen
SET
Displays Fault Log
or
SET
SET
SET
SET
Approx.
5 sec.
SET
or
SET
SET
Approx.
5 sec.
SET
SET
Main Screen
READY
RANGE FLTR1
*If the Control Panel does not have a Warm (Up) button, but
rather a single Temp button, use the Temp button in place
of the Warm button in the instruction above. (The flow chart
assumes a single Temperature Button.)
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2009 Balboa Water Group.
Template 56377 10-05-12
8
56497-02/56498-02/56499-02/56562-01_97_B 04-15-14
Equipment Expansion
Expansion Features
Control Connection
Default
Fuse
Relay 1/2 (J108)
None
None
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2009 Balboa Water Group.
Template 56377 10-05-12
9
56497-02/56498-02/56499-02/56562-01_97_B 04-15-14
DIP Switch Functions
Fixed-fuction DIP Switches
1
A1
Test Mode (normally Off).
A2
In “ON” position, add one high-speed pump (or blower) with Heater.
A3
In “ON” position, add two high-speed pumps (or 1 HS Pump and Blower) with Heater.
A5
In “ON” position, enables Special Amperage Rule B. See Special Features section under Configuration Options for functionality with your system.
In “OFF” position, enables Special Amperage Rule A.
A6
Persistent memory reset (Used when the spa is powering up to restore factory settings as determined by software configuration).
6
S1
ON
A2 and A3 work in combination to determine the number of high-speed devices and blowers that can run before the heat is disabled. i.e. A2 and A3 in the ON position will
allow the heater to operate with up to 3 high-speed pumps (or two HS Pumps and Blower) running at the same time. Heat is disabled when the fourth high-speed pump or
blower is turned on.
Note: A2/A3 all off = No heat with any high-speed pump or blower.
Assignable DIP Switches
A4
In “ON” position, enables a 5-minute cooldown for some gas heaters (Cooling Time B).
In “OFF” position, enables a 1-minute cooldown for electric heaters (Cooling Time A).
Undesignated switches are not assigned a function.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2009 Balboa Water Group.
Template 56377 10-05-12
10
56497-02/56498-02/56499-02/56562-01_97_B 04-15-14
Jumper Definitions
J109
Non Applicable on CE models
J30
Do Not Use
31
Jumper on 1 pin with 2.0kW or smaller heater
J109
Jumper setting varies by system model
which is shown to the right of the jumper.
Jumper on 2 pins with a 3.0kW or higher heater
J29
Heater Disable Switch Connection. If J29 is shorted by any means, the heater will not run until J29 is no longer shorted.
If J29 is shorted during power-up “J29” will appear on the panel.
The message can be dismissed with a button press, and is the only control panel notification of J29 being shorted.
No message is displayed if J29 is shorted after power-up, but the heater will not run until J29 is no longer shorted.
J31
56562-01
J31
56497-02, 56498-02, 56499-02
J29
J29 expects a switch closure (not a voltage) as the command signal.
In some areas, a local power company may offer discounts based on voluntary “power shedding” devices that may be installed in conjunction with the spa.
J25, J26, J27
Heater Type Settings.
Note:
J44
J27
Factory Configured do not change.
J25
Jumper must be on center two pins (230V) for CE Systems.
Warning!
Setting DIP switches or jumpers incorrectly may cause abnormal system behavior and/or damage to system components.
Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system.
Contact Balboa if you require additional configuration pages added to this tech sheet.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2009 Balboa Water Group.
Template 56377 10-05-12
11
56497-02/56498-02/56499-02/56562-01_97_B 04-15-14
J44
J26
230V
115V
115V
BP601 Configuration Options
General Features
Feature
Default
Pump 1 in Filter Cycle (Circ Only)
No
Pump 1 Low Timer
30 Minutes
General Pump Timer
15 Minutes
Blower Timer
15 Minutes
Mister Timer
15 Minutes
Light Timer
240 Minutes
Circ (when enabled)
Programmable + Polling
Applies in non-circ Setups (configurations) only
Circ Pump can be set with the following functions:
24 hr – 24 hr w/3° shutoff – Acts like P1 Low (filters, polls, etc. - Requires a single-speed P1)
Cleanup Cycle
30 Minutes
Between 30 and 240 minutes
- or OFF
30 Minutes
Cleaup as Preference setting
Yes
Yes, No
N/A
Ozone
With Heater Pump*
Always, Filters/Cleanup Only
N/A
Ozone Suppression
OFF
Between 30 and 120 min.
- or OFF
1 Minute
Pump Purge
60 Seconds
Between 30 and 600 seconds
5 Seconds
Blower Purge
30 Seconds
Between 5 and 300 seconds
5 Seconds
Mister Purge
5 Seconds
Purge Type
Serial - Pumps at lowest speed
* The heater Pump can be either a Circ Pump or Pump 1 Low.
Blue Indicates New Custom Configuration Default (Setup 1)
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2009 Balboa Water Group.
Template 56377 10-05-12
12
56497-02/56498-02/56499-02/56562-01_97_B 04-15-14
BP601 Configuration Options
Temperature Features
Feature
Default
Temperature Display
°C
Options
Increment
°C, °F
All temperatures must be specified in °F. The system converts °F to °C dynamically. If Celsius is required for default settings, choose a desired °C value that (after rounding) corresponds to a Fahrenheit value.
°C
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
°F
39
41
43
45
46
48
50
52
54
55
57
59
61
63
64
66
68
70
72
°C
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
°F
73
75
77
79
81
82
84
86
88
90
91
93
95
97
99 100 102 104
Hi-Range Min. Set Temp
80°F
Between 50 and 80°F
1°F
Hi-Range Max. Set Temp
104°F
Between 60 and 104°F
1°F
Hi-Range Default Temp*
100°F
Between 50 and 104°F
1°F
Lo-Range Min. Set Temp
50°F
Between 50 and 80°F
1°F
Lo-Range Max. Set Temp
99°F
Between 60 and 99°F
1°F
Lo-Range Default Temp*
70°F
Between 50 and 99°F
1°F
Freeze Threshold
44°F
Freeze Type
Rotating - Pumps at Lowest Speed
Temp Lock Type
Temp + Settings
*May be changed by end-user (if enabled)
Blue Indicates New Custom Configuration Default (Setup 1)
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2009 Balboa Water Group.
Template 56377 10-05-12
13
56497-02/56498-02/56499-02/56562-01_97_B 04-15-14
BP601 Configuration Options
Time Features
Feature
Default
Options
Increment
Time Format*
24 Hour
12 Hour, 24 Hour
N/A
Filter 1 Start Hour*
20:00 (8:00 PM)
00:00 to 23:00
1 Hour
Filter 1 Duration*
2 Hours
Between 15 Min and 23:45
-or continuous
15 Minutes
Filter Cycle 2 Default*
OFF
OFF, ON
N/A
Filter 2 Start Hour*
08:00 (8:00 AM)
00:00 to 23:00
1 Hour
Filter 2 Duration*
15 Minutes
Between 15 Min and 23:45
-or Continuous, or Disabled
15 Minutes
Light Cycle
Disabled
Disabled, Enabled
N/A
Light Cycle Default*
OFF
OFF, ON
N/A
Light Cycle Start Hour*
21:00 (9:00 PM)
00:00 to 23:00
1 Hour
Light Cycle Duration*
15 Minutes
Between 15 Min and 04:00
-or or Disabled
15 Minutes
Cooling Time A
1 Minute
Cooling Time B
5 Minutes
*May be changed by end-user (if enabled)
Blue Indicates New Custom Configuration Default (Setup 1)
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2009 Balboa Water Group.
Template 56377 10-05-12
14
56497-02/56498-02/56499-02/56562-01_97_B 04-15-14
BP601 Configuration Options
Reminder Features
Feature
Default
Reminders Shown*
Yes
Yes, No
N/A
Check pH
OFF
See Reminder Period Note
1 Days
Check Sanitizer
OFF
See Reminder Period Note
1 Days
Clean Filter
30 Days
Test GFCI
65 Days
See Reminder Period Note
1 Days
Drain Water
100 Days
See Reminder Period Note
1 Days
Change Cartridge
OFF
Clean Cover
OFF
See Reminder Period Note
1 Days
Treat Wood
OFF
See Reminder Period Note
1 Days
Change Filter
365 Days
Options
See Reminder Period Note
See Reminder Period Note
See Reminder Period Note
Increment
1 Days
1 Days
1 Days
Reminder Periods can be set between 7 and 180 days. In addition, 365 days can be chosen.
Each reminder can be turned OFF individually.
*May be changed by end-user (if enabled)
Blue Indicates New Custom Configuration Default (Setup 1)
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2009 Balboa Water Group.
Template 56377 10-05-12
15
56497-02/56498-02/56499-02/56562-01_97_B 04-15-14
BP601 Configuration Options
Special Features
Feature
Default
Special Amperage Rule A
No Limitation
Special Amperage Rule B
1 HS Pump - Blower turns off with 1 HS Pump
Drain Mode
Disabled
Disabled, Enabled
N/A
Demo Mode
Disabled
Disabled, Enabled
N/A
GFCI Trip
Not Applicable for CE Models
Automatic GFCI Test
Disabled
Ozone Slaved to Heater Pump
Yes
Disabled, 1-7 Days
1 Day
Yes, No
N/A
Dual Voltage Heater
Always Input Voltage
4°F Temperature Delta
N/A
Safety Suction
Disabled
Disabled, Enabled
N/A
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2009 Balboa Water Group.
Template 56377 10-05-12
16
56497-02/56498-02/56499-02/56562-01_97_B 04-15-14
TP800 Panel Configuration
Button Layout Table
Feature
#
Setup 1
Setup 2
Setup 3
Setup 4
Setup 5
Setup 6
A1
N/A
N/A
N/A
N/A
N/A
N/A
A2
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
A3
Jets 2
Jets 2
Blower
Blower
Light 1
Light 1
A4
Light 1
Light 1
Light 1
Light 1
Invert
Invert
A5
Invert
Invert
Invert
Invert
Undefined
(Circ Icon)
A6
Undefined
(Circ Icon)
Undefined
(Circ Icon)
Undefined
Undefined
A7
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
A8
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
A9
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
A10
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
A11
N/A
N/A
N/A
N/A
N/A
N/A
A12
N/A
N/A
N/A
N/A
N/A
N/A
A13
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
A14
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
A15
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
A16
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
B1
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
B2
Undefined
Undefined
Undefined
Undefined
Undefined
Undefined
B3
Jets 2
Jets 2
Blower
Blower
Undefined
Undefined
B4
Light 1
Light 1
Light 1
Light 1
Light 1
Light 1
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2009 Balboa Water Group.
Template 56377 10-05-12
17
56497-02/56498-02/56499-02/56562-01_97_B 04-15-14
TP800 Panel Configuration
Spa Screen
B1
A6
B2
A2
A3
A4
A5
A7
A8
A9
A10
B3
Note: Button B2 is ALWAYS unused on TP800 when used with
this sytsem. A custom overlay will be required.
B4
Shortcuts Screen
A13
B1
A13
A14
B2
B3
A15
A14
A16
B4
A15
A16
Note: Buttons 11 and 12 are
not used in this configuration.
Button 1 is fixed.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2009 Balboa Water Group.
Template 56377 10-05-12
18
56497-02/56498-02/56499-02/56562-01_97_B 04-15-14
TP600 Panel Configuration
Button Layout Table
Button
#
Setup 1 & 2
Setup 3 & 4
Setup 5 & 6
1
Jets 1
Jets 1
Jets 1
2
Jets 2
Blower
Undefined
3
Invert
Invert
Invert
4
Up
Up
Up
5
Light 1
Light 1
Light 1
6
Down
Down
Down
LED 1
Jets 1
Jets 1
Jets 1
LED 2
Jets 2
Blower
Undefined
LED 3
Light 1
Light 1
Light 1
LED 4
Heat On
Heat On
Heat On
1
4
4
1
2
2
5
READY
3
3
6
1 2
3 4
1 2
3 4
TP600CE
50015-04 or later
No Overlay
TP600 (non-CE) should not be used.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2009 Balboa Water Group.
Template 56377 10-05-12
19
56497-02/56498-02/56499-02/56562-01_97_B 04-15-14
5
RANGE FLTR1
6
TP400 Panel Configuration
Button Layout Table for TP400T
Button
#
Setup 1 & 2
Setup 3 & 4
Setup 5 & 6
1
Temperature
Temperature
Temperature
2
Jets 1
Jets 1
Jets 1
3
Light 1
Light 1
Light 1
4
Jets 2
Blower
Undefined
LED 1
Heater ON
Heater ON
Heater ON
LED 2
Jets 1 ON
Jets 1 ON
Jets 1 ON
LED 3
Light ON
Light ON
Light ON
LED 4
Jets 2 ON
Blower ON
Undefined
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
TP400T
Button Layout Table for TP400W
Button
#
All Setups
1
Up
2
Down
3
Light 1
4
Jets 1
LED 1
Heater ON
LED 2
Undefined
LED 3
Light ON
LED 4
Jets 1 ON
50260-02 or later
Includes overlay PN 12511.
Use the TP400W for setups that only have
one pump (No Blower or Pump 2).
TP400W
50259-01 or later
Includes overlay PN 12510.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2009 Balboa Water Group.
Template 56377 10-05-12
20
56497-02/56498-02/56499-02/56562-01_97_B 04-15-14
BP601 Configuration Options
Auxilliary Panel Features on Bank 1*
Feature
Default
Aux Button A1
Jets 1
Aux Button A2
Jets 2 in Setups 1 & 2
Blower in Setups 3 & 4
Undefined in Setups 5 & 6
Aux Button A3
Undefined
Aux Button A4
Light
*Bank 1 consists of J5 on the Main Circuit Board.
Aux Connection Splitter PN25257 may be required.
Buttons that are assigned to equipment that is
not defined in a Setup will not do anything in that Setup.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2009 Balboa Water Group.
Template 56377 10-05-12
21
56497-02/56498-02/56499-02/56562-01_97_B 04-15-14
BP601 Configuration Options
Auxilliary Panel Features
AX10 Panels on Bank 1*
A1, AX10A1
No O/L
52803
A2, AX10A2
No O/L
52804
A3, AX10A3
No O/L
55805 A4, AX10A4
No O/L
52806
Call Customer Service for
additional information about Auxiliary Panels.
Blower
Jets 1
Auxiliary Panel Part Number _____________________
Overlay Part Number
_____________________
*Bank 1 consists of J5 on the Main Circuit Board.
Aux Connection Splitter PN25257 may be required.
AX20
AX20 A1A2
No O/L
52800
AX20 A1A3
No O/L
52801
AX20 A1A4
No O/L
52802
AX20 Auxiliary Panel plugged into Bank 1 will operate A1 + A2, A3 or A4.
A2, 3 or 4
A1
AX40
AX40
AX40 Auxiliary Panel plugged into Bank 1 will operate A1 + A2, A3 and A4.
No O/L
52799
A1
A2
A3
A4
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2009 Balboa Water Group.
Template 56377 10-05-12
22
56497-02/56498-02/56499-02/56562-01_97_B 04-15-14