null  null
Prices as of April 15, 2015. Check Web site for most current prices.
Company
Information
Control Systems
Overview
Programmable
Logic Controller­s
(PLC) Overview
CLICK PLC
Do-More
PLCs Overview
Do-More H2
PLC
Do-More T1H
PLC
DirectLOGIC
PLCs Overview
Up-to-date price list:
www.automationdirect.com/pricelist
FREE Technical Support:
www.automationdirect.com/support
DirectLOGIC
DL105
DirectLOGIC
DL205
FREE Videos:
www.automationdirect.com/videos
FREE Documentation:
www.automationdirect.com/documentation
In this interactive PDF you can:
•Use bookmarks to navigate
by product category
DirectLOGIC
DL05/06
FREE CAD drawings:
www.automationdirect.com/cad
DirectLOGIC
DL305
DirectLOGIC
DL405
Productivity
Controller
Overview
Productivity
3000
•Use bookmarks to save,
search, print or e-mail the
catalog section
•Click on part #s to link
directly to our online store
for current pricing, specs,
stocking information and
more
Universal
Field I/O
Software
C-More
HMI
C-More Micro
HMI
ViewMarq
Industrial
Marquees
Other HMI
Communications
Appendix
Book 1
Terms and
Conditions
Book 1 (14.2)
www.automationdirect.com/directlogic-plcs
DirectLOGIC PLC Overview
eDL-1
Prices as of April 15, 2015. Check Web site for most current prices.
DirectLOGIC Programmable Controller
Overview
DL05:
Offers cost-effective
features with an expansion slot
The DL05 series is a fixed I/O PLC with eight inputs and six outputs with one option
card slot, and features you won’t find in most bricks — six I/O combinations of AC,
DC and relay I/O, and advanced programming functions such as PID.
See DS section
•Eight inputs and six outputs
•2 K program memory
•4 K data memory
•Two built-in communication ports
•Over 250 instructions, including four PID loops
•Removable terminal block
•12/24 VDC powered versions
•Discrete and analog I/O modules
• Thermocouple and RTD modules
•Ethernet and serial communications
modules
•1-channel high-speed input/pulse output module
•Memory cartridge/real-time clock module
•DeviceNet™ / Profibus slave modules
•Basic CoProcessor module
DL06:
Mighty micro PLC
with 36 I/O and four expansion slots
The DL06 series combines its fixed I/O of 20 inputs and 16 outputs with four
option card slots for expansion all in the same package. With the DL06, you can
use the same PLC panel layout for all applications from 36 to 100 I/O.
See DS section
•20 inputs and 16 outputs
•7.5 K program memory
•7.3 K data memory
•Two built-in communication
ports - one RS232 and one
RS232/422/485 port
•Over 275 instructions, including
eight PID loops and ASCII
•Removable terminal blocks
•Built-in 300 mA 24 VDC
auxiliary power supply
•12/24 VDC powered versions
•Built-in real-time clock/calendar
•Discrete and analog I/O modules
• Thermocouple and RTD modules
•Ethernet and serial communications
modules
•High speed input/pulse output module
•DeviceNet™ and Profibus slave
modules
•Basic CoProcessor module
•Optional plug-in LCD display
DL105:Fixed-I/O Micro PLC
The DL105 series is a fixed-I/O micro PLC with 10 inputs and eight outputs.
Eight configurations are available in combinations of AC, DC and relay I/O.
•10 inputs and eight outputs
•2 K program memory
•384 words data memory
•110/220 VAC or 24 VDC power supply versions
•Built-in 0.5A, 24 VDC
auxiliary power supply
•One RS-232 communication port
•Heavy-duty seven amp relays with built-in surge suppression on
models with relay outputs
See D1 section
Book 1 (14.2)
eDL-2
DirectLOGIC PLC Overview
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
DirectLOGIC Programmable Controller
Overview
Company
Information
Control Systems
Overview
CLICK PLC
DL205: Micro-modular PLC with a wide range of I/O
and communications modules
If your application requires the flexibility of a modular system, a DL205 PLC is a low
cost, yet extremely versatile solution.
•Four CPUs, up to 30.4K memory and 16,384 I/O
• Four base sizes available
•16 buit-in PID loops using D2-260 CPU
•AC/DC input/output modules
• Up to 10 A relay outputs
•12-bit and 16-bit analog I/O modules
•Thermocouple and RTD input modules
•Ethernet and serial communications modules
Do-More
PLCs Overview
Do-More H2
PLC
Do-More T1H
PLC
•Ethernet and serial remote I/O
•High-speed counter/pulse
output modules
•Basic CoProcessor module
•Ethernet, DeviceNet™ and Profibus slave
controller modules
•Triple port serial module
DirectLOGIC
PLCs Overview
DirectLOGIC
DL05/06
DirectLOGIC
DL105
DirectLOGIC
DL205
See D2 section
DirectLOGIC
DL305
DirectLOGIC
DL405
Productivity
Controller
Overview
DL305: We’ve still got it!
Productivity
3000
The DL305 series is a small modular PLC that has been marketed by
various name brand PLC manufacturers for over 30 years. This Koyo design
revolutionized the small PLC market, and you can keep your DL305 system
operating with these compatible components.
•Three CPUs, including the D3-350 with PID
control and two communication ports
•Five, eight and 10 slot bases
•110/220 VAC or 24 VDC power supply
Universal
Field I/O
Software
C-More
HMI
•AC, DC inputs
•AC, DC and relay outputs
•Analog input/output
C-More Micro
HMI
See D3 section
ViewMarq
Industrial
Marquees
Other HMI
Communications
Appendix
Book 1
DL405:
Specialty modules
for complex applications
Terms and
Conditions
The DL405 PLC product line has a wide choice of specialty I/O modules,
including high-speed counting, temperature controller, and magnetic pulse input.
•Three CPUs, up to 30.8K memory and
16,384 I/O
•Three base sizes with built-in power supply
•16 built-in PID loops (D4-450 CPU),
up to 96 loops using PID modules
•AC/DC input/output modules
•10 A relay outputs
•12-bit and 16-bit analog I/O modules
•Thermocouple and RTD input modules
•Ethernet and serial communications modules
•Ethernet and serial remote I/O master and
slave modules
See D4 section
Book 1 (14.2)
www.automationdirect.com/directlogic-plcs
DirectLOGIC PLC Overview
eDL-3
Prices as of April 15, 2015. Check Web site for most current prices.
How many other companies offer
a money-back guarantee on software?
DirectSOFT6 programs
the entire DirectLOGIC
family
PC-DSOFT6 is our DirectLOGIC PLC
programming package, with a host of
features that make it easier to program
your PLC. It supports full-featured 32-bit
Windows-based program­ming for all six
DirectLOGIC PLC families simultane­
ously, including all DL05s, DL06s,
DL105s, DL205 CPUs, DL305 CPUs,
DL405 CPUs, and most of their Koyo
cousins. The software supports a wide
array of on-line/off-line programming
and docu­men­ta­tion features, as well as
IBox instructions.
Packages include:
• PC-DS100/version 6 (FREE):
DirectSOFT100 programming package; programs up to 100 words in any
DirectLOGIC CPU
• PC-DSOFT6 is the full programming
package for all DirectLOGIC PLCs with no
programming limitations, at one low price
$395.00
• PC-R60-U upgrade to Version 6 with
complete DirectLOGIC CPU support from
any older purchased version
$249.00
Technicians like it
when you use our
programming and
documentation tools
A well-documented program can save
thousands of dollars in downtime when
something breaks, but not all packages
make it easy to document the program.
Use our grid-based documentation editor
to quickly and intuitively create rung
comments, 16-character element nicknames, 6 x 19-character element descriptions, and 16-character wiring labels.
What’s New in
DirectSOFT6?
• Over 40 new IBoxes available
• Configurable toolbars
• Extremely fast status updates
• New Trend View feature for monitoring
and debugging (seen below)
• Graphic Ladder View
• Ladder box leg labels
• Graphic Stage View
What else is included?
• IBoxes have packetized fill-in-the-blankstyle instructions that make writing your
program faster and easier (certain CPUs
and firmware required)
• Tabbed views optimize your viewing area
so you see more of what you need to see
• Customizable tool bars give you the
flexibility to put what you need where you
want it
• Dockable windows give you the ability to
relocate views, auto-hide views and even
tear them away and place them outside of
the DirectSOFT6 workspace for full ladder
viewing optimization
• Learn many features and software
shortcuts with the “Tip of the Day” in
DirectSOFT6
• Edit programs as fast as you can move a
mouse or use ‘hot keys’ (even faster)
• Write your program with nicknames
instead of data points
• View your program three different ways
(RLL, Stage View, Mnemonics). Select the
appropriate Tab or view them all on the
same screen
• Reduced scan time by scanning
only active stages
• Spr
e adsheet-style documentation editor
makes it super easy to create and edit
your program docu­menta­tion on the fly
• I/O cross-reference and element usage
windows keep track of addresses used
• Print Preview to check print formatting
• Print in COLOR
• Open a Data View to examine a status
chart of information you select
• PID setup is a snap. Fill-in-the-blanks for
alarms, mode, ramp/soak, process variable, setpoint, gain rate, etc.
• PID loop tune and trending screens are
standard
• Modem support is a snap since it uses the
standard Windows telephony (TAPI)
interface to choose modem configuration
• Our drum timers are the easiest to create
and edit in the industry
• Programming support for all DirectLOGIC
CPUs
• ASCII in/out and MODBUS instructions for
DL06 and D2-260 CPUs
• Support for DL205 local I/O expansion
system in D2-250-1, D2-260, and DL-405
CPUs
• Support for LCD instructions in the DL06
CPU
• Project backup feature and preferences
with auto-backup settings for “file
freshen” frequency
• Import/export program (mnemonics and
rung comments) allows for archiving a
program in a single file (txt or CSV) that
does not need to be in the form of a
DirectSOFT6 file(s) format
• Export to C-more operator interface
CSV import format (nickname, type, PLC
address) to use the same tags in our PLC
program and operator interface
configuration
Program over Ethernet
You can program one or multiple
DirectLOGIC PLCs from one location over
an Ethernet network. Just insert an ECOM
100 module in supported DL05, DL06,
DL205 and DL405 systems to monitor
and program at warp speed! An Ethernet
setup wizard leads you through the steps
to make the connection to your PLCs.
Book 1 (14.2)
eDL-4
DirectLOGIC PLC Overview
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
DirectSOFT6 for DirectLOGIC PLCs
Company
Information
Control Systems
Overview
DirectSOFT6 makes programming
your PLC easy and fast
CLICK PLC
We have taken the guesswork out of everyday programming with IBox instructions. The IBox instructions are
intelligent modularized instructions that perform simple to
complex ladder logic. If you need to set up an Analog
card just fill in the blanks; If you need to perform a math
function on a value, simply type in your formula; select a
new preset for your High Speed Counter (CTRIO); even
send an e-mail with your ECOM100 Ethernet communications module! Take a minute to view the IBox Instruction
Help index to see detailed specifications of each of the
105 instructions, review which CPUs support the IBox
instructions or just get familiar with what they can do for
you. Other features include:
• Point and click or function key editing to suit anyone’s
programming style
• Customizable Tool Bars for EVERY menu command
• Desktop Themes to allow you to customize your window
and tool bar look & feel
• All toolbars can be docked to any border or even floated
outside of the DirectSOFT window for maximum ladder
viewing
• Write your program with nicknames instead of data points
• I/O cross reference and element usage windows keep track
of addresses used
• Set up the D0-DCM for the DL05 & DL06 right from the menu.
PLC > Setup > D0-DCM allows you to configure each of the
two serial ports, no ladder code required
Do-More
PLCs Overview
Do-More H2
PLC
Do-More T1H
PLC
DirectLOGIC
PLCs Overview
DirectLOGIC
DL05/06
DirectLOGIC
DL105
DirectLOGIC
DL205
DirectLOGIC
DL305
DirectLOGIC
DL405
Productivity
Controller
Overview
Productivity
3000
Universal
Field I/O
Software
The 40+ new IBoxes in DirectSOFT6 are compatible
with DirectLOGIC DL05, DL06, D2-250-1, D2-260,
and D4-450 CPUs that have supporting firmware. IBox
instruction categories include Memory, Discrete Helper,
Analog Helper, Math, Communications, and CTRIO.
C-More
HMI
C-More Micro
HMI
NOTE: Using Ibox instructions can increase the program size and PLC scan
time.
ViewMarq
Industrial
Marquees
Other HMI
Stage programming keeps the
sequence in order
Communications
Appendix
Book 1
RLLPLUS Stage programming can help break a control
problem into smaller pieces and provide such benefits as:
• Stages divide the ladder program into sections that
correspond to the states in a flowchart of your process
• Stages help make large programs more manageable by
giving them some structure
• Reduce scan time by scanning only the active stages
Terms and
Conditions
Book 1 (14.2)
www.automationdirect.com/directlogic-plcs
DirectLOGIC PLC Overview
eDL-5
Prices as of April 15, 2015. Check Web site for most current prices.
DirectSOFT6 Packages for DirectLOGIC PLCs
Programming
software
PC-DSOFT6$395.00
PC-DS100Free
Overview
DirectSOFT6 Programming Software has
been designed to make DirectLOGIC PLC
programming easier than ever before.
The 32-bit Windows-based package
provides simple menu and icon choices
that operate similarly to those found in
most standard Windows packages. With
DirectSOFT6 you can have the power of
Windows on the factory floor.
Flexible configuration allows you to customize the look and feel of the software to suit your needs and desires.
Laptop/portable
computers and
off-site usage
www.automationdirect.com/directsoft
Many of you may be using laptop
computers for field service work. This is
perfectly acceptable as long as it adheres
to the guidelines described previously.
Which package is right
for you?
Can I ship a copy to my
customer?
To download our free version, please visit
our Web site at:
The programming software packages
share the same general features, but
there are a couple of key differences:
PC-DSOFT6 programs all six CPU families
(DL05, DL06, DL105, DL205, DL305 and
DL405).
PC-DS100 is a free, full-feature software
package that allows a maximum of 100
words for programming, editing, and
downloading. Larger programs can be
created and saved but NOT reopened or
downloaded without purchasing the full
version.
No, except for a single backup copy,
you cannot make, install, or distribute
any additional copies. You can transfer
the original copy (original CD, any applicable upgrades, and any documentation)
by taking advantage of our Web registration and ownership transfer site.
Maintenance releases
You can receive maintenance releases
at no charge by downloading them from
our Web site. These often include some
minor feature enhancements along with
software corrections.
Software upgrades
PC-R60-U $249.00
Any release that contains major feature
enhancements will be subject to the
normal upgrade charge in effect at that
time. The DirectSOFT6 upgrade part
number is PC-R60-U.
Note: This upgrade will update any older packages
that are already installed on your system to a full
programming package with all CPU support.
Of course, this means you cannot legally
keep a copy once you have transferred
the original.
Number of users
The packages listed above are really
“single-station” packages. That is, you
can legally install them on only one
computer. However, if there is only one
person who primarily uses the computer
(over 80% of the time), then you can
install the software on a laptop, home
office, or any other single backup
computer.
Book 1 (14.2)
eDL-6
DirectLOGIC PLC Overview
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
DirectSOFT6 Features
Program editing features
• “Tip of the Day” gives you programming
guidance, information on shortcuts and
tips for taking advantage of features
• Full-screen Point and Click Editing with
the mouse and icons
• Edit Tool Box contains icons and hot key
equivalents for all elements
• Browsers help you find proper
addresses, contacts, coils, and box
instructions
• Windows XP (Home or Pro)/
Vista (all 32-bit and 64-bit versions) /
Windows 7/Windows 8/8.1 features
fully customizable and tear-off toolbars,
Tool Tips, long file names, common file
browsers
• Project Information data with each
project including creation and save
dates, links, PLC type, project description
and version, and company/ department/
programmer
• On-screen Cross Reference in a tabbed
view that automatically tracks program
elements as you browse the ladder view
• On-screen Element Usage in groups of 8,
10, or 16 points per line
• Predefined aliases for common items,
such as timer and counter current values
• Enter your program with nicknames and
assign them to addresses later
• Access V-memory (Data Registers) with
fill-in-the-blank Memory Editor
• Easily cut and paste single rungs or
groups of rungs
• Cut and paste rungs (with documentation) between programs
• Search for program elements by name,
address, rung number, or instruction type
• Search for constants
Documentation features
• I mport/export program mnemonics and
rung comments to a text file that does not
have to be in DirectSOFT format
• E xport (nickname, type, PLC address) to
C-more in CSV format
•G
rid-based documentation editor for
easy access
• 16-character nicknames for addresses
make troubleshooting and programming
easier
• 16-character wiring information allows
you to tie PLC addresses to panel wiring
numbers
• 6-line x 19-character address description
provides more detailed information
about the program element
• Rung comments can be up to 20 lines of
70 characters each
• Cut, copy, and paste documentation
between program elements
• Free-form program title page can be
selected at time of printing
• Import/Export feature for all
documentation
Company
Information
Printing features
• Print any available view, including
ladders, charts, and mnemonics
• Print multiple columns
• Use zoom to enlarge or reduce print size
• Preview the printouts before you send
them to the printer
• Create custom printouts by selecting
exact items to include for each view
• Print program documentation, including
nicknames, descriptions, rung
comments, etc.
• Print program Cross Reference or
Element Usage Table
• Print PLC V-memory or Data Register
contents
Display and
viewing features
•Tabbed views allow you to easily switch
between views and optimize your
viewing area
• View program ladders
• Customizable desktop themes, display
colors for editing, unsaved changes,
documentation, etc.
• View program mnemonics
• Stage view available for programs
created with RLLPLUS instructions
• Choose rung number or addresses for
ladder view
• View multiple programs at the same time
• View multiple screens at once
• Use split screen to view different
sections of the same program
• Use zoom to enlarge or reduce the screen
area for better viewing
System setup features
• D0-DCM Setup menu is available for the
DL05 and DL06 data communications
module
• Set up PID loops with easy-to-use dialog
boxes
• Set PLC communication parameters
through PC ports, modems, or Ethernet
• Change PLC mode of operation
• Clear PLC memory by type or all
• Select or change retentive memory
ranges
• Read PLC I/O configuration
• Change I/O configuration (if allowed by
the PLC)
• View PLC firmware revisions
Online operation
features
• Online help system with supported CPU
instruction list
• DSLaunch as a central manager for all
projects, links, and applications
• Automatically build and store
communication links to the PLC,
even using modems or Ethernet
• Visible indication of PLC communication
link status
• Status mode provides visible power flow
condition for program elements, current
values for timers and counters, and
current values for V-memory or Data
Register locations. Event status for Drum
steps, outputs, event and/or time
transitions, etc.
• Custom configure Data View windows to
monitor various elements
• Display nicknames in Data View
• Save and store Data View windows by
name
• Choose data format for Data View
Window display (BCD, binary,
Hexadecimal, etc.)
• Choose status symbol (switch, text, etc.)
for discrete points in Data View windows
• Change PLC values from Data View
windows
• View multiple PLCs simultaneously
(Ethernet)
Maintenance and
debugging
• Automatic error checking during
program entry
• Program syntax check
• Monitor PLC scan time
• Perform PLC I/O diagnostics
• View PLC errors and/or user error
messages
• Project user backup and auto
back-up facilities
• Visually monitor data values using
the Trend View feature
DirectLOGIC PLC Overview
CLICK PLC
Do-More
PLCs Overview
Do-More H2
PLC
Do-More T1H
PLC
DirectLOGIC
PLCs Overview
DirectLOGIC
DL05/06
DirectLOGIC
DL105
DirectLOGIC
DL205
DirectLOGIC
DL305
DirectLOGIC
DL405
Productivity
Controller
Overview
Productivity
3000
Universal
Field I/O
Software
C-More
HMI
C-More Micro
HMI
ViewMarq
Industrial
Marquees
Other HMI
Communications
Appendix
Book 1
Terms and
Conditions
Book 1 (14.2)
www.automationdirect.com/directlogic-plcs
Control Systems
Overview
eDL-7
Prices as of April 15, 2015. Check Web site for most current prices.
DirectSOFT6 Functions
Click to start
programming
The Launch Window
The Launch Window is a centralized location to view not only
all of your DirectSOFT6 applications and projects, but also any
additional applications such as NetEdit, DN Loader, CTRIO
WB, ERM WB, etc. This window is also used to create and
manage PLC programs and the communications between your
PC and the PLC.
Utilities, such as
CTRIO WB
Installed support
Documents —
(Projects most recently
used listed first)
Communication links to PLCs
Point and click editing
Once you have started a new project, there are a few different ways to
start building your program. The Ladder Palette, which is attached to the
right border by default, can be resized and repositioned anywhere on your
desktop. This contains most of the instructions you will need. Simply click
on the icon or use the Hot Key associated with that icon. Some instructions have to be accessed through one of the Browser icons. The Browsers
contain all of the necessary information from various boxes, coils, and
contacts. You can now customize the Ladder Palette tool bar to fit your
programming style and needs.
Description, Wiring Info, Nickname, Element
Enter documentation information for each instruction/element.
Edit and review all documentation
Ladder Palette
Documentation
Documentation is the text associated with the components and
structure of your program. It helps to clarify the representation of
elements by assigning four different fields: Description, Wiring
Info, Nickname, and Element.
Onscreen views
DirectSOFT6 defaults to a Tab view to give you the most optimized viewing area.
You still have the option to view multiple windows in the original “MDI” format by
simply hitting the Restore button in the upper right of the active tabbed window,
or go to Windows menu and select one of the tile or cascade options. You can
have multiple windows open to view such things as all of the addresses used in the
program, a mnemonic view of the program instructions, and all of the instructions
used.
You can have multiple
views of your project
visible at the same
time. This screen shows
the Ladder View, Usage
View, Mnemonic View
and XRef View.
Book 1 (14.2)
eDL-8
DirectLOGIC PLC Overview
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
DirectSOFT6 Functions
Company
Information
Control Systems
Overview
CLICK PLC
Support for drum instructions
If your PLC supports Drum instructions, you will like this feature of the programming software. Simply fill in the top of the drum with outputs and configure each
step with an event and/or time-based element. Then click on the output boxes to
choose the proper output states for each step and you are finished.
Do-More
PLCs Overview
Do-More H2
PLC
Do-More T1H
PLC
DirectLOGIC
PLCs Overview
DirectLOGIC
DL05/06
PID view
DirectSOFT6 offers an excellent PID feature. The loop and trending screens
are very easy to configure. This feature has all of the views, trending, and
tuning that you need to easily and successfully set up your PID loop.
DirectLOGIC
DL105
DirectLOGIC
DL205
DirectLOGIC
DL305
DirectLOGIC
DL405
Trend view
DirectSOFT6 contains a new debugging tool called Trend View.
Trend View is used to visually monitor the values of DL controller
data elements over time. The Trend View can monitor any readable
numeric location, any readable bit location or any constant value.
Productivity
Controller
Overview
Productivity
3000
Universal
Field I/O
Software
C-More
HMI
I-Box Instructions
C-More Micro
HMI
IBox instructions are parameterized fill-in-the-blank instructions designed to
make your programming experience quicker and easier than ever before.
Within these IBoxes you will find some complicated and some simple,
everyday ladder code tasks made easy and fast. There are 6 categories,
including Memory, Discrete Helper, Analog Helpers, Math, Communications
& Counter I/O, with 105 instructions to choose from. Here are a few examples of IBox instructions in DirectSOFT6 …
ViewMarq
Industrial
Marquees
Other HMI
Communications
MOVER - Copies a 32-bit floating point number that is stored in two consecutive V-Memory locations to the specified location which is also two consecutive V-Memory location
Appendix
Book 1
Terms and
Conditions
OFFDTMR - Off Delay Timer will delay the “turning off” of the Output
parameter by the specified Off Delay Time
ABSR - Returns the absolute value of the Real (floating point) number found
in the specified V-Memory locations
ANLGCMB - Analog Input/Output Combo Module Pointer Setup generates
the logic to configure the pointer method for one analog input/output combo
module on the first PLC scan following a Program to Run transition.
MATHBCD - Math - BCD Format lets you enter complex mathematical
expressions like you would in Visual Basic, Excel, or C++
Book 1 (14.2)
www.automationdirect.com/directlogic-plcs
DirectLOGIC PLC Overview
eDL-9
Prices as of April 15, 2015. Check Web site for most current prices.
Programming for DirectLOGIC PLCs
Programming versions
With DirectSOFT6 Programming Software,
selecting which software package you
need is a snap! You can select the fully
loaded package at its great low price, or
you may choose the FREE package. It has
all of the same programming functions
as the full package. However, it will only
download a program up to 100 words
long.
The fully-loaded version (PC-DSOFT6)
will program all of our DirectLOGIC
PLCs, some GE Series One Plus PLCs,
and TI305/405 SIMATIC PLCs. Refer to
the chart below to verify compatibility.
DL205
DL305
DL405
GE® Series 1 PLUS
TI305™/ SIMATIC®
TI305™
TI405™/ SIMATIC®
TI405™
Koyo Kostac S-Series
Also, you cannot open an offline project
larger than 100 words. You can create a
project as large as you want and save it
to disk, but you cannot reopen or download it to a PLC without purchasing the
full version (PC-DSOFT6).
PLC compatibility
If you’re using our DirectLOGIC products, then compatibility is not an issue.
The DirectSOFT6 package supports all
DirectLOGIC CPUs. Our software also
supports many compatible products that
were offered by previous vendors of the
Koyo-designed PLCs. If you’re buying
the software to program a compatible
CPU, check the following table to make
sure your CPU is supported. (Sorry, but
if your CPU is not shown, then it is not
supported.)
DirectSOFT6
(full version)
PC-DSOFT6
DirectSOFT6
(free version)
PC-DS100*
CPU Firmware Version
Needed to Use IBox
Instructions
All
4
4
4 CPU v5.10 or Later
All
All
D2-230
D2-240
D2-250
D2-250-1
D2-260
D3-330**, D3-330P**
D3-340
D3-350
D4-430
D4-440
D4-450
IC610CPU105**
IC610CPU106**
325-07**, PPX:325-07**
330-37**, PPX:330-37**
325S-07** (or 325 with Stage Kit)
330S-37**, PPX:330S-37**
335-37, PPX:335-37
425-CPU, PPX:425-CPU
PPX:430-CPU
435-CPU, PPX:435-CPU
PZ1
PZ2
PZ3
SC-4X
SG-8/8B
SL-4
SU-5/5E/5M
SU-6/6B/6H/6M
SZ-3
SZ-4/4M
TJ-435/435-AS
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4 CPU v2.10 or Later
Family
DL05
DL06
DL105
The FREE DirectSOFT6 package
(PC-DS100) was designed to provide
a more streamlined choice. You can
see from the table below that the FREE
version has the same support and same
great features, but will only allow you to
open or download a program up to 100
words long.
CPU
4 CPU v4.60 or Later
4 CPU v2.40 or Later
4 CPU v3.30 or Later
* PC-DS100 is only available by download from our Website. This FREE, full-featured software package will download a program limited to 100 words.
** Requires Data Communications Unit (D3-232-DCU).
Book 1 (14.2)
eDL-10
DirectLOGIC PLC Overview
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
Programming for DirectLOGIC PLCs
Company
Information
PC system compatibility
Control Systems
Overview
Following are the recommended system requirements for running DirectSOFT6
on a PC:
• 1 GHz CPU
• CD/DVD drive OR an Internet connection for loading software
• Windows XP (Home and Pro)/Vista (all 32-bit and 64-bit versions)/Windows 7/
Windows 8/8.1 (No DOS, OS/2, MacIntosh, Windows XP 64-bit, LINUX or UNIX versions, or 16-bit versions available)
• 512 MB RAM and 50 MB free hard disk space
• At least one unused serial communications port or USB port using our USB-RS232,
USB-to-serial adapter and/or 10-Base-T or 10/100-Base-T Ethernet network card
• Color SVGA monitor (1024 x 768)
CLICK PLC
Do-More
PLCs Overview
Do-More H2
PLC
Do-More T1H
PLC
DirectLOGIC
PLCs Overview
DirectLOGIC
DL05/06
NOTES:
Laptops: DirectSOFT6 is perfectly suitable for use with laptop computers as long as they meet the
requirements shown above. Most laptops can be ordered with a serial port as an option, which will
allow a direct connection to our DirectLOGIC PLCs. If your laptop has a USB port, consider using
our USB to serial adapter, USB-RS232. If your laptop has an Ethernet port and you are considering
a DL05, DL06, DL205 or DL405 PLC, consider using the Hx-ECOM100 Ethernet Communications
Module to connect your PC to the PLC (The D2-230 does not support the ECOM).
Monitors: Any size monitor will work, however, larger, higher resolution monitors enhance the
features of DirectSOFT6.
Connecting to DirectLOGIC PLCs
DirectLOGIC
DL105
DirectLOGIC
DL205
DirectLOGIC
DL305
DirectLOGIC
DL405
DL06 CPUs
Productivity
Controller
Overview
Port 1: 9.6 Kbaud
Port 2: 300 baud - 38.4K baud
Productivity
3000
Universal
Field I/O
DL05 CPUs
Port 1: 9.6 Kbaud
Port 2: 300 baud-38.4 Kbaud
Software
C-More
HMI
DL205 CPUs
DL105 CPUs
C-More Micro
HMI
D2-230: Port 1: 9.6 Kbaud
D2-240: Port 1: 9.6 Kbaud
Port 2: 300 baud - 19.2 Kbaud
D2-250-1: Port 1: 9.6 Kbaud
& D2-260Port 2: 300 baud - 38.4 Kbaud
ViewMarq
Industrial
Marquees
Other HMI
Port 1: 9.6 Kbaud
Communications
Appendix
Book 1
Terms and
Conditions
DL305 CPUs
D3-330 (requires D3-232-DCU): 300 - 19.2 Kbaud
D3-340: Port 1/2: 300 baud - 38.4 Kbaud
D3-350: Port 1: 9.6 Kbaud
Port 2: 300 baud - 38.4 Kbaud
DL405 CPUs
D4-430: Port 1: 9.6 Kbaud
&D4-440: Port 2: 300 baud - 19.2 Kbaud
D4-450: Port 0: 9.6 Kbaud
Port 1: 300 baud - 38.4 Kbaud
Port 2: 300 baud - 38.4 Kbaud
Or use an Hx-ECOM100 module in the DL05, DL06, DL205 (except D2-230) or
DL405 local base to program over a high-speed Ethernet link.
Book 1 (14.2)
www.automationdirect.com/directlogic-plcs
DirectLOGIC PLC Overview
eDL-11
Prices as of April 15, 2015. Check Web site for most current prices.
DirectLOGIC PLC Programming Cables
Since CPUs provide many different communication port possibilities, it is helpful to know
exactly which communications cable is required. Use the table below to choose the
proper cable:
Family
CPU (or other device)
D2-DSCBL (EA-MG-PGM-CBL optional)
Port 2
D2-DSCBL (EA-MG-PGM-CBL optional)
Only one
**
Port 1
D2-DSCBL (EA-MG-PGM-CBL optional)
Port 2
D2-DSCBL-1
Port 1
D2-DSCBL (EA-MG-PGM-CBL optional)
Port 2
D2-DSCBL-1
Only one
**
Port 1
D2-DSCBL (EA-MG-PGM-CBL optional)
Port 2
D2-DSCBL-1
F1-130 (all versions)
Only one
D2-DSCBL (EA-MG-PGM-CBL optional)
D2-230
Only one
D2-DSCBL (EA-MG-PGM-CBL optional)
Top port
D2-DSCBL (EA-MG-PGM-CBL optional)
Bottom port
D2-DSCBL (EA-MG-PGM-CBL optional)
Top port
D2-DSCBL (EA-MG-PGM-CBL optional)
Bottom port
D2-DSCBL-1
Top port
D2-DSCBL (EA-MG-PGM-CBL optional)
Bottom port
D2-DSCBL-1
D2-DCM (module)
Only one
D3-DSCBL-2
H2-ECOM (-F) / ECOM100
Only one
**
D3-330/D3-330P
Requires DCU*
D3-DSCBL-2
Top port
D3-DSCBL-1
Bottom port
D3-DSCBL-1
Top port
D2-DSCBL (EA-MG-PGM-CBL optional)
Bottom port
D3-DSCBL-2
Only one
D3-DSCBL-2
Top port (15-pin)
D4-DSCBL
Bottom port (25-pin)
D3-DSCBL-2
Phone jack
D2-DSCBL (EA-MG-PGM-CBL optional)
Top port (15-pin)
D4-DSCBL
Bottom port (25-pin)
D3-DSCBL-2
D4-DCM (module)
Only one
D3-DSCBL-2
H4-ECOM (-F) / ECOM100
Only one
**
Slice I/O (module)
Only one
D4-DSCBL
IC610CPU105/106
Requires DCU*
D3-DSCBL-2
325-07, PPX:325-07
Requires DCU*
D3-DSCBL-2
330-37, PPX:330-37
Requires DCU*
D3-DSCBL-2
325S-07 (or 325 with stage kit)
Requires DCU*
D3-DSCBL-2
330S-37, PPX:330S-37
Requires DCU*
D3-DSCBL-2
Phone jack
D3-DSCBL-1
If DCU is used*
D3-DSCBL-2
If DCU is used*
D4-DSCBL
Top port (15-pin)
D4-DSCBL
Bottom port (25-pin)
D3-DSCBL-2
Top port (15-pin)
D4-DSCBL
Bottom port (25-pin)
D3-DSCBL-2
Only one
D4-DSCBL
H0-ECOM / ECOM100 (modules)
D0-DCM (module)
All versions
DirectLOGIC DL06
H0-ECOM / ECOM100 (modules)
D0-DCM (module)
DirectLOGIC DL105
D2-240
DirectLOGIC DL205
D2-250(-1)
D2-260
D3-340
DirectLOGIC DL305
D3-350
D3-DCM (module)
D4-430/D4-440
DirectLOGIC DL405
GE® Series 1
TI305™/SIMATIC® TI305™
D4-450
335-37, PPX:335-37
425-CPU, PPX:425-CPU
TI405™/SIMATIC® TI405™
Cable
Port 1
All versions
DirectLOGIC DL05
Port
N/A, PPX:430-CPU
435-CPU, PPX:435-CPU
Smart slice
* Requires RS232 Data Communications Unit (D3-232-DCU).
**Requires standard Ethernet twisted pair cable (HX-ECOM) or standard fiber optic cable (HX-ECOM-F).
***The GoldX USB-RS232 adapter is another option for USB communication.
Book 1 (14.2)
eDL-12
DirectLOGIC PLC Overview
1-800-633-0405
Prices as of April 15, 2015. Check Web site for most current prices.
DirectLOGIC PLC Programming Cables
Company
Information
Control Systems
Overview
D2-DSCBL $14.00
CLICK PLC
D2-DSCBL-1 $30.00
Do-More
PLCs Overview
Do-More H2
PLC
Do-More T1H
PLC
DirectLOGIC
PLCs Overview
DirectLOGIC
DL05/06
D3-DSCBL-1 $30.00
DirectLOGIC
DL105
D3-DSCBL-2 $30.00
D3-350 (bottom port)
or
DL405 CPU (bottom port)
or
DL205/405 DCM
or
DL305 w/DCU
RS-232
DirectLOGIC
DL205
DirectLOGIC
DL305
DirectLOGIC
DL405
Productivity
Controller
Overview
Productivity
3000
D4-DSCBL $30.00
Universal
Field I/O
Software
C-More
HMI
C-More Micro
HMI
ViewMarq
Industrial
Marquees
Straight-through Patch Cable (Ethernet)
Other HMI
Communications
Appendix
Book 1
Terms and
Conditions
Crossover Cable (Ethernet)
Book 1 (14.2)
www.automationdirect.com/directlogic-plcs
DirectLOGIC PLC Overview
eDL-13
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement